2017 specification book isn’t in the house at all · 2017 specification book the best room in the...
TRANSCRIPT
1
2017 SPECIFICATION BOOK
THE BEST ROOM IN THE HOUSE
ISN’T IN THE HOUSE AT ALL
VER: 04-11-17
2
ITEM PAGE NUMBER
OUTDOOR FIREPLACES 4
FIRE FURNISHINGS 12
IGNITION SYSTEMS 14 - 17
ROUND BURNES 18
SQUARE BURNERS 22
FLAT DISC 26
L-SERIES 30
NON-LISTED BURNERS 34
AnF OUTDOOR LIVING ENCLOSURES 38
SPUR BURNERS 40
FLEXFRAME 41
PAVER KIT CONTROL PANELS 42
PAVER VENT KITS 43
MEDIA 44
CONTROLS 46
LIDS 48
WINDSHIELDS 49
VENT KIT 50
GAS LINE PIPE SIZING CHART / PROPANE TANK BTU’S
51
CUSTOM ORDER FORM 52
LIVE BURN PROGRAM 54
LITERATURE ORDER FORM 56
WARRANTY 59
HOW TO SIGN UP FOR
Go to www.firegearoutdoors.com and click on the CAD Details icon in the bottom right corner of the home page.
Once on the Firegear Outdoors CAD Detail website, click any product on the page.
Scroll down until you see REGISTER. Click the register button, input the information and finish the sign up process.
Once you are signed up, you then will have access to all of Firegear Outdoors design files.
3
Skytech Products Group-Retail, including Skytech Systems and Firegear Outdoors (“SPG-Retail”), a Division of Skytech Products Group, has developed a Minimum Advertised Pricing (MAP) policy (the “Policy”) for all products sold by and purchased from SPG-Retail by and through traditional and/or online retailers (“Products”). In an effort to protect the image and value of SPG-Retail products and to maintain fair and equitable promotional and sales activity among its distributors, dealers, retailers and other resellers (each, a “Retailer”), SPG-Retail has developed the MAP Policy effective immediately. The MAP Policy and its terms and conditions are as follows:
Subject to certain exceptions set forth below, no Retailer shall, at any time, advertise or promote any SPG-Retail Products for sale or resale at a price lower than the MAP pricing established by SPG-Retail for such Products.
The MAP Policy shall apply to all promotions and/or advertisements of any Products purchased from SPG-Retail that appear in any media form, including, without limitation, written or electronic flyers, posters, coupons, mailers, inserts, newspapers, magazines, catalogs, mail order catalogs, Internet, online, or similar electronic media, websites, email newsletters, email solicitations, television, radio, and/or public signage. The MAP Policy shall not apply to (a) any in-store advertising displayed by a Retailer, in-store displays, point-of-sale signs, hang tags or bar codes, or similar product price packaging which merely state the price of such product; (b) the promotion or advertisement of discontinued Product, so long as such Product is clearly marked as discontinued within said advertisement or promotion; and (c) the actual price at which any Products are sold to an individual consumer at or from a Retailer’s physical location or via telephone.
MAP pricing is subject to change from time to time at the sole discretion of SPG-Retail and can be accessed by contacting SPG-Retail Divisions at (888) 672 8929, or by written request via email at [email protected] or [email protected]. It shall be the responsibility of all Retailers to remain current as to MAP Policy, pricing, and any changes thereto.The MAP Policy shall apply to all Products sold to SPG-Retail distributors and resold thereby to any Internet or online dealers and retailers, and such distributors shall take all necessary steps to enforce the MAP Policy in connection with each and every such resale.By accepting Products from SPG-Retail and in consideration of continued access to Products and the benefits realized as an SPG-Retail preferred, approved Retailer, each Retailer accepts and all Products they purchase from SPG-Retail shall be and remain subject to the MAP Policy as set forth herein. Should it be determined that any Product subject to the MAP Policy is or has been advertised or promoted at a price below the MAP pricing established for said Product by SPG-Retail at any time, the violating Retailer shall immediately take all steps necessary to cure said violation and bring its advertising, promotion, pricing and sales activity into compliance with the MAP Policy. SPG-Retail hereby, at any time, reserves the right to discontinue the shipment of Products to the violating Retailer and/or its distributor, and the right to terminate future sales of Products to said violating Retailer and/or its distributor, subject to the parties’ respective financial and confidential obligations that shall survive such termination.
POLICY
APPLICATION
OTHER TERMS & CONDITIONS
MAP POLICY MINIMUM ADVERTISED POLICY
4
KALEA BAY SPECIFICATIONS
MODEL
OVERALL LENGTH
A
INSIDE OPENING
B
OVERALL HEIGHT
C
OPENINGHEIGHT
D
OVERALL DEPTH
E
LEG HEIGHT
F
VALVE BOX
DEPTHG
CLEARANCE TO COMBUSTABLE
SIDE WALLH
CLEARANCE TO COMBUSTABLE
CEILINGI
OFP-36LTFS-N or P 40” 36" 37 1/2" 16” 16” 11 1/2" 8 3/4” 6” 42 1/2”
OFP-48LTFS-N or P 52” 48" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”
OFP-60LTFS-N or P 64” 60" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”
OFP-72LTFS-N or P 76” 72" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”
FRONT VIEW
TOP VIEW
END VIEW
E
E
C
6”
20”
F
D
A
B
GBottom Finish Fin
Hood
I
H
END VIEW
SIDEWALL
CEILING
FLOOR
11½”
FRONT VIEW
TOP VIEW
END VIEW
E
E
C
6”
20”
F
D
A
B
GBottom Finish Fin
Hood
SINGLE SIDED FIREPLACE DIMENSIONS & CLEARANCES
OPTIONAL ACCESSORIES326-930 Driftwood 6 piece twig set
TM-R-AF1TX Wireless wall mount timer (30/60/120min)
1322WT Wireless wall mount switch (On/Off/High/Low)
1001D-AF1TX Wireless wall mount switch (On/Off)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)
WS Wired wall mount switch (On/Off)
OFP-48LTFS-N 48” w x 16” h x 16” d opening dimensions. Natural Gas (43,500 Btu on High, 24,500 Btu on Low)
OFP-60LTFS-N 60” w x 16” h x 16” d opening dimensions. Natural Gas (50,000 Btu on High, 36,000 Btu on Low)
OFP-72LTFS-N 72” w x 16” h x 16” d opening dimensions. Natural Gas (65,000 Btu on High, 42,000 Btu on Low)
OFP-36LTFS-N 36” w x 16” h x 16” d opening dimensions. Natural Gas (31,000 Btu on High, 18,500 Btu on Low)
OFP-36LTFS-P 36” w x 16” h x 16” d opening dimensions. Liquid Propane (30,000 Btu on High, 19,500 Btu on Low)
OFP-48LTFS-P 48” w x 16” h x 16” d opening dimensions. Liquid Propane (42,500 Btu on High, 29,000 Btu on Low)
OFP-60LTFS-P 60” w x 16” h x 16” d opening dimensions. Liquid Propane (50,000 Btu on High, 36,000 Btu on Low)
OFP-72LTFS-P 72” w x 16” h x 16” d opening dimensions. Liquid Propane (60,000 Btu on High, 45,000 Btu on Low)
MODELS
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
FIREPLACES
5
MODEL
OVERALL LENGTH
A
INSIDE OPENING
B
OVERALL HEIGHT
C
OPENINGHEIGHT
D
OVERALL DEPTH
E
LEG HEIGHT
F
VALVE BOX
DEPTHG
CLEARANCE TO COMBUSTABLE
SIDE WALLH
CLEARANCE TO COMBUSTABLE
CEILINGI
OFP-36LTFS-N or P 40” 36" 37 1/2" 16” 16” 11 1/2" 8 3/4” 36” 42 1/2”
OFP-48LTFS-N or P 52” 48" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”
OFP-60LTFS-N or P 64” 60" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”
OFP-72LTFS-N or P 76” 72" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”
FRONT VIEW
TOP VIEW
END VIEW
E
E
C
6”
20”
F
D
A
B
GBottom Finish Fin
Hood
FRONT VIEW
TOP VIEW
END VIEW
E
E
C
6”
20”
F
D
A
B
GBottom Finish Fin
Hood
SEE-THROUGH FIREPLACE DIMENSIONS & CLEARANCES
I
H
END VIEW
SIDEWALL
CEILING
FLOOR
11½”
6
MODELWIDTH
AHEIGHT
BDEPTH
C
OFP-L36TFS-N or P 40 1/2” 37 3/4" 16”
OFP-L48TFS-N or P 52 1/2” 37 3/4” 16”
OFP-L60TFS-N or P 64 1/2” 37 3/4” 16”
OFP-L72TFS-N or P 76 1/2” 37 3/4” 16”
METAL STUDS
A
B
C
Metal Studs Metal Studs
Met
al S
tudsMet
al S
tuds
*Metal studs shown in gray.
Bottom Support Fin
Hood
MODELWIDTH
AHEIGHT
BDEPTH
C
OFP-L36TFS-N or P 52” 49 1/2" 28”
OFP-L48TFS-N or P 64” 49 1/2” 28”
OFP-L60TFS-N or P 76” 49 1/2” 28”
OFP-L72TFS-N or P 88” 49 1/2” 28”
WOOD STUDS
A
B
CWood Studs Wood Studs
Woo
d St
uds
Woo
d St
uds
*Wood studs shown in gray.
Bottom Support Fin
Hood
Stando�sStando�s
Wood Studs
NOTE: The Kalea Bay fireplace is not a “load bearing” fireplace. All finishing materials must be supported by the surrounding structure and not rely on the fireplace itself.
FOR BOTH SINGLE SIDED & SEE-THROUGHKALEA BAY FRAMING DIMENSIONS
7
CONVERTING KALEA BAY INTO A SEE-THROUGH FIREPLACE
BACK VIEW REAR PANEL INSTALLED
BACK VIEW REAR PANEL REMOVED
Bottom Finish Fin
Side View Detail for Removal Rear Panel Screws
If you have determined to install the fireplace as a see-through model then you will need to remove the rear back panel to convert it. Before removing the back panel be sure to remove the contents out of the firebox area.
Use the following steps:
Step 1: Look at the back side of the fireplace. Around the outer perimeter area of the frame or back wall are several screws to remove.
Note: The numbers of screws to remove will vary with each fireplace model.
Step 2: The back panel will not be used again in the see-through application. Keep the back panel and screws if you need to switch the unit back to a single sided unit.
Watch for sharp edges
NOTE: When converting to the see-through fireplace the windshield clips will need to be installed. Two windshield clips are already installed for a single-sided fireplace, the other two clips will need to be installed for a see-through model. The clips will be packaged with the glass windshields. The retaining screws for the clips are already installed in the fireplace. Simply remove the screws and re-attach with the windshield clips in place.
The see-through fireplace requires both windshields to be intalled for proper operation.
The bottom support fin has pre-punched holes on the inside edge to secure fin into place before attaching cement board and the additional hood will need to be installed.
8
HIGH ELEVATION: This unit is approved from altitude 0 to 4500 ft (CAN12.17-M91)
MODELSOD42-N Outdoor Linear Fireplace includes 2’’ Brushed Stainless
Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Natural Gas
OD42-P Outdoor Linear Fireplace includes 2’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Propane
OD42-4-N Outdoor Linear Fireplace includes 4’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Natural Gas
OD42-4-P Outdoor Linear Fireplace includes 4’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Propane
OPTIONAL ACCESSORIES326-900 Steel stud framing kit. Overall dimensions 60”
wide x 20” deep x 52 1/2” high
326-930 Driftwood 6 piece twig set
1001-A Wireless hand held remote (On/Off)
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
OD42 SPECIFICATIONS
OD42-N or P DIMENSIONS
NOTES
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-001.
OD42 OUTDOOR FIREPLACE
OD42
5053-001
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/15/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
OD42-N
LP GAS:
#29 44,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#47 43,500MIN. INLET 5.0" WC 11.0" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
14.0" WC3.5" WC
14.0" WC10.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
OD42-P
OD42-NOD42-P
I NT ER EK
L I ST ED
US
CM
FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 2" STAINLESS STEEL
TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.
22 5/8"
35 1/4"
39 1/2"
12 3/4"17"
15 9/16"
11 1/2"10"
32 7/16"
23 5/16"
6 3/4"
6 5/16"
5/8"
FRONT VIEW SIDE VIEW
HEAT SHIELD
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-001.
OD42 OUTDOOR FIREPLACE
OD42
5053-001
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/15/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
OD42-N
LP GAS:
#29 44,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#47 43,500MIN. INLET 5.0" WC 11.0" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
14.0" WC3.5" WC
14.0" WC10.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
OD42-P
OD42-NOD42-P
I NT ER EK
L I ST ED
US
CM
FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 2" STAINLESS STEEL
TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.
22 5/8"
35 1/4"
39 1/2"
12 3/4"17"
15 9/16"
11 1/2"10"
32 7/16"
23 5/16"
6 3/4"
6 5/16"
5/8"
FRONT VIEW SIDE VIEW
HEAT SHIELD
OD42-4-N or P DIMENSIONS
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-002.
OD42-4 OUTDOOR FIREPLACE
OD42
5053-002
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/20/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
OD42-4-N
LP GAS:
#29 44,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#47 43,500MIN. INLET 5.0" WC 11.0" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
14.0" WC3.5" WC
14.0" WC10.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
OD42-4-P
OD42-4-NOD42-4-P
FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 4" STAINLESS STEEL
TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.
FRONT VIEW SIDE VIEW
15 9/16"
11 1/2"10"5/8"
32 7/16"
25 5/16"
6 3/4"
4 5/16"
22 5/8"35 1/4"
43 1/4"
12 3/4"20 3/4"
I NT EREK
L I ST ED
US
CM
HEAT SHIELD
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-002.
OD42-4 OUTDOOR FIREPLACE
OD42
5053-002
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/20/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
OD42-4-N
LP GAS:
#29 44,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#47 43,500MIN. INLET 5.0" WC 11.0" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
14.0" WC3.5" WC
14.0" WC10.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
OD42-4-P
OD42-4-NOD42-4-P
FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 4" STAINLESS STEEL
TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.
FRONT VIEW SIDE VIEW
15 9/16"
11 1/2"10"5/8"
32 7/16"
25 5/16"
6 3/4"
4 5/16"
22 5/8"35 1/4"
43 1/4"
12 3/4"20 3/4"
I NT EREK
L I ST ED
US
CM
HEAT SHIELD
MODEL BTUSPECIFICATIONS
FACTORYORIFICE
BTUOUTPUT
OD42-N #29 44,500
OD42-P #47 43,500
OD42-N or P SYSTEM INFO
PRESSUREGAS
TYPE NGGAS
TYPE LP
MIX INLET 5.0”WC 11.0”WC
MAX INLET 14.0”WC 14.0”WC
MANIFOLD 3.5”WC 10.0”WC
MODEL BTUSPECIFICATIONS
FACTORYORIFICE
BTUOUTPUT
OD42-4-N #29 44,500
OD42-4-P #47 43,500
OD42-4-N or P SYSTEM INFO
PRESSUREGAS
TYPE NGGAS
TYPE LP
MIX INLET 5.0”WC 11.0”WC
MAX INLET 14.0”WC 14.0”WC
MANIFOLD 3.5”WC 10.0”WC
Tested to CAN/CGA-2.17-M91 / IAS 4-96 (US) / CGA CR97-003 (CAN) 4001172
9
The clearances listed below are Minimum distances unless otherwise stated.
A major cause of fire is failure to maintain required clearances (air space) to combustable materials. It is of the greatest importance that the fireplace be installed only in accordance with these instructions.
A
B
F
E
D
AC
BF
Clearance Dimension Measured From
A: Sidewall 11’’ (203mm) Side of fireplace opening
B: Ceiling 36’’ (914mm) Top of fireplace opening
C: Mantel Height (min) 26 1/2’’ (673mm) Top of fireplace opening
D: Mantel Depth (max) 12’’ (304mm) From wall
E: Alcove Width 57’’ (1148mm) Wall to wall (min)
F: Alcove Depth 36’’ (914mm) Front to back wall (max)
Notes: 0’’ No hearth requiredThis table corresponds with the images below
F
E
When selecting a location for your fireplace, ensure that the proper clearances are met. Please refer to the product install manual for the measurement points to maintain proper distances.
MINIMUM CLEARANCES TO COMBUSTIBLES
OD42 FRAMING KITMODEL #: 326-900
NOTES:2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.2. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AND WELL AS ALL GAS CONNECTIONS.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE DRAWING ABOVE.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-003.
OD42 326-900 - FRAMING KIT
OD42
5053-003
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/15/2016
SELECT DESIRED SYSTEM:
OD42 FRAMING KIT
326-900
OD42 FRAMING KIT CONTAINS: (2) TOP/BOTTOM SUPPORTS, (8) TALL VERTICAL SUPPORTS, (6) SHORT VERTICAL SUPPORTS, (1) BASE, (1) HEADER, (2) CORNER BRACES, (1) CENTER VERTICAL SUPPORT, (1) VENT-KIT-6X12 AND (80) WAFER SCREWS.
TOOLS REQUIRED FOR ASSEMBLY: POWER DRILL, #2 HAND SCREWDRIVER, LEVEL AND TAPE MEASURE. NON-COMBUSTIBLE CEMENT BOARD IS NOT SUPPLIED. SEE 326-900 FRAMING KIT INSTALL MANUAL FOR MORE DETAILS.
ISOMETRIC
60"
20"
11"
18 1/2"
18"
52 1/2"
HEAT SHIELD
10
KEY WEST SEE-THROUGH SPECIFICATIONS
MODELSKWST-42-N (1) FPB-30LTFS-N or P, Steel Stud Framing Kit
(KD - Knock Down) Ready to assemble, pre-drilled and labeled. Stainless Steel Reflective Side Walls and Ceiling Panel, Fireglass (10lb.), GWS-3810 Glass Windshield, On/Off/High/Low Remote Control (RCAF-3), VENT-KIT-6x12
OPTIONAL ACCESSORIES
KWST-42-P
KWST-82-N (2) FPB-30LTFS-N or P, Ready to Finish Enclosure (Assembled), Fireglass (20lb.), GWS-6810 Glass Windshield, On/Off/High/Low Remote Control (RCAF-3), VENT-KIT-6x12
KWST-82-P
326-930 Driftwood 6 piece twig set
TM-R-AF1TX Wireless wall mount timer (30/60/120min)
1322WT Wireless wall mount switch (On/Off/High/Low)
1001D-AF1TX Wireless wall mount switch (On/Off)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)
LID-68L Linear stainless steel lid with brushed finish for the KWST-82
377-909 Key West See Through kit propane drawer kit (KWST-42-N only)
LID-30L Linear stainless steel lid with brushed finish for the KWST-42
WS Wired wall mount switch (On/Off)
NOTES
KWST-42 SPECIFICATIONS
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.
5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-008.
KWST42 SYSTEM
KEY WEST SEE THRU
5053-008
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/20/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
KW42ST-N
LP GAS:
#35 42,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
HI
#47 42,000MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
10.5" WC7.0" WC
13.0" WC11.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
FPB-30LTFS-N
FEATURES: KWST42 SYSTEM COMES WITH EITHER (1) FPB-30LTFS-N OR (1) FPB-30LTFS-P BURNERS, READY TO ASSEMBLE FRAMING KIT, 20 LBS OFFIREGLASS, GWS-3812 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROL AND (1) VENT-KIT-6X12.
SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.
CUT OUT DIMENSIONS FOR BURNERS
FPB-30LTFS-P23,000
BTU OUTPUTLOW
30,000
KW42ST-P
PERSPECTIVE
FRAMING PERSPECTIVE
51"
11"64 1/16"
19"
8 1/2"
20 1/2"
42"
2"
4 7/8"
37"
9 1/4"
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.
5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-008.
KWST42 SYSTEM
KEY WEST SEE THRU
5053-008
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/20/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
KW42ST-N
LP GAS:
#35 42,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
HI
#47 42,000MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
10.5" WC7.0" WC
13.0" WC11.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
FPB-30LTFS-N
FEATURES: KWST42 SYSTEM COMES WITH EITHER (1) FPB-30LTFS-N OR (1) FPB-30LTFS-P BURNERS, READY TO ASSEMBLE FRAMING KIT, 20 LBS OFFIREGLASS, GWS-3812 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROL AND (1) VENT-KIT-6X12.
SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.
CUT OUT DIMENSIONS FOR BURNERS
FPB-30LTFS-P23,000
BTU OUTPUTLOW
30,000
KW42ST-P
PERSPECTIVE
FRAMING PERSPECTIVE
51"
11"64 1/16"
19"
8 1/2"
20 1/2"
42"
2"
4 7/8"
37"
9 1/4"
MODEL BTUSPECIFICATIONS
FACTORYORIFICE
BTU OUTPUTHIGH
BTU OUTPUTLOW
FPB-30LTFS-N #35 42,000 23,000
FPB-30LTFS-P #47 42,000 30,000
PRESSURE GAS TYPE NG GAS TYPE LP
MIN INLET 5.0” WC 10.5” WC
MAX INLET 10.5” WC 13.0” WC
MANIFOLD 7.0” WC 11.0” WC
KWST-42-N or P uses one (1) FPB-30LTFS-N or P
KWST-82-N or P uses two (2) FPB-30LTFS-N or P
The area below the burner must remain empy to allow proper air ventilation
Non-Combistible board withvent installed
11
MINIMUM CLEARANCES TO COMBUSTABLES
KWST-82 SPECIFICATIONS
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.
6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-005.
KWST82 SYSTEM
KEY WEST SEE THRU
5053-005
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/15/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
KWST-82-N
LP GAS:
#35 84,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
HI
#47 84,000MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
10.5" WC7.0" WC
13.0" WC11.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
FPB-30LTFS-N (2)
FEATURES: KWST82 SYSTEM COMES WITH EITHER (2) FPB-30LTFS-N OR (2) FPB-30LTFS-P BURNERS, READY TO FINISH ASSEMBLED ENCLOSURE,20 LBS OF FIREGLASS, 377-955 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, TWO RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROLS AND (1)
VENT-KIT-6X12. SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.
KWST-82-P
FPB-30LTFS-P (2)46,000
BTU OUTPUTLOW
60,000
81 1/2"
24"6 3/4"
54 1/2"
11" 79 1/4"27 3/4"
19 1/2"
102"
7 1/2"
8 3/8"
67"6"
NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.
6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-005.
KWST82 SYSTEM
KEY WEST SEE THRU
5053-005
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/15/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
KWST-82-N
LP GAS:
#35 84,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
HI
#47 84,000MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETMANIFOLD
10.5" WC7.0" WC
13.0" WC11.0" WC
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU
SPECIFICATIONS.
FPB-30LTFS-N (2)
FEATURES: KWST82 SYSTEM COMES WITH EITHER (2) FPB-30LTFS-N OR (2) FPB-30LTFS-P BURNERS, READY TO FINISH ASSEMBLED ENCLOSURE,20 LBS OF FIREGLASS, 377-955 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, TWO RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROLS AND (1)
VENT-KIT-6X12. SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.
KWST-82-P
FPB-30LTFS-P (2)46,000
BTU OUTPUTLOW
60,000
81 1/2"
24"6 3/4"
54 1/2"
11" 79 1/4"27 3/4"
19 1/2"
102"
7 1/2"
8 3/8"
67"6"
MODEL BTUSPECIFICATIONS
FACTORYORIFICE
BTU OUTPUTHIGH
BTU OUTPUTLOW
(2) FPB-30LTFS-N #35 84,000 46,000
(2) FPB-30LTFS-P #47 84,000 60,000
PRESSURE GAS TYPE NG GAS TYPE LP
MIN INLET 5.0” WC 10.5” WC
MAX INLET 10.5” WC 13.0” WC
MANIFOLD 7.0” WC 11.0” WC
Finished side withvent installed
The area below the burner must remain empy to allow proper air ventilation
Model Ceiling Side Wall Floor
KWST-42-N or P 45 17 22
KWST-82-N or P 45 17 27 3/4
A
B
C
12
KEY WEST BISTRO SPECIFICATIONS
MODELS
KWBTO-L-SS Key West Bistro Table with Iron Grey Base and Stainless Steel Top, 286-927 Stainless Steel Top, 34,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).
OPTIONAL ACCESSORIES
326-930 Driftwood 6 piece twig set
286-932 Tempered Glass Windshield (14 1/2” Long x 14 1/2” Wide x 6” Tall) Black Polyester Cover included
286-938 Protective Weather Cover
KWBTO-L-IG Key West Bistro Table with Iron Grey Base and Top, KWBTO-L, 286-924 Iron Grey Top, 34,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).
286-968 Key West Bistro Table Natural Gas conversion kit
Shown with optional Glass Windshield (286-932)
DIMENSIONS
CLEARANCE TO COMBUSTIBLES
AA
B
C
D
E
F
CLEARANCE DIMENSION MEASURED FROM
A: Back Wall 17” (432mm) Burner to back wall
B: Side Wall 17” (432mm) Burner to side wall
C: Ceiling 45” (1143mm) Burner to ceiling
D1: Floor 0” When using supplied leveling legs
D2: Floor 1” (25mm) Unit base to floor
E: Alcove Width 84” (2134mm) Wall to wall MIN
F: Alcove Depth 60” (1524mm) Front to back wall MAX AA
B
C
D
E
F
Tested and listed by Intertek for installation in USA and Canada
13
KEY WEST COFFEE TABLE SPECIFICATIONS
MODELS
KWCH-P-BR Key West Coffee Table with Sunset Bronze Top, KWCH-L1, 377-926 Table Top, 49,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).
OPTIONAL ACCESSORIES
326-930 Driftwood 6 piece twig set
GWS-3812 Tempered Glass Windshield (38” Long x 12 7/8” Wide x 7 1/2” Tall)
376-029 Black Polyester Cover for GWS-3812
KWCH-P-SS Key West Coffee Table with Stainless Steel Top, KWCH-L1, 377-927 Table Top, 49,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).
376-968 Natural Gas conversion kit for Key West Coffee Table (KWCH-P-SS & KWCH-P-BR), 50,000 BTU
377-938 Protective Weather Cover for Key West Coffee Table
DIMENSIONS
CLEARANCE TO COMBUSTIBLES
AA
B
C
D
E
F
CLEARANCE DIMENSION MEASURED FROM
A: Back Wall 17” (432mm) Burner to back wall
B: Side Wall 17” (432mm) Burner to side wall
C: Ceiling 45” (1143mm) Burner to ceiling
D1: Floor 0” When using supplied leveling legs
D2: Floor 1” (25mm) Unit base to floor
E: Alcove Width 84” (2134mm) Wall to wall MIN
F: Alcove Depth 60” (1524mm) Front to back wall MAX AA
B
C
D
E
F
Tested and listed by Intertek for installation in USA and Canada
14
IGNITION SYSTEMS
MATCH THROW (MT)
KEY VALVEINCOMING GAS LINE
GAS FLEX LINE TO BURNER
HOW TO LIGHT1. Insert key into shut-off valve and secure key onto square end of the valve.
2. Light a long match or Butane lighter and hold it near the burner.
3. Turn the key counter-clockwise on gas valve (until it stops) to allow gas to flow and simultaneously apply the long burning
match or Butane lighter as close to the end of the burner as possible.
4. Gas should ignite within 10 seconds or less. If fire pit does not light within 10 seconds turn key clockwise to turn OFF the gas
supply. Ensure there is not too much media on top of the burner that might inhibit gas flow and try again in 5-minutes. Please
refer to page 42 for the recommended amount of media to install for your pan size.
7/8” Washer
Brass Nut
OASNG#(Burner Ori�ce)
U3-8D-S (Fitting)
Spur Burner
KC-PC(Decorative Flange)
BVS (Manual Key Valve)
U1-8D-S
U1-8D-S (Fitting)
Fire Pit Pan
Inlet Gas Supply
Expanded View of Match Throw (MT) Fire Pits
T200-9898-46 (Flex Connector)
Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.
(Not Supplied)
REV. 2-16-17MT Expanded View
EXPANDED VIEW
15
THERMOCOUPLEVALVE
INCOMING GAS LINE
GAS FLEX LINE TO BURNER THERMOCOUPLECONNECTION
1. Light a long match or Butane lighter and hold it near the burner.
2. Rotate the control knob of the gas valve counter-clockwise to the ON position.
3. Depress control knob inward and push to light the burner at the same time.
4. After the fire pit lights continue to depress the control knob for 30 seconds then release knob. If the fire pit does not light within 30 seconds,
release knob, turn knob clockwise to turn OFF and wait 5 minutes before trying again.
HOW TO LIGHT
REV. 2-16-17TMS Expanded View
7/8” Washer
Brass Nut
OASNG#(Burner Ori�ce)
U3-8D-S (Fitting)
Expanded View of Thermocouple Manual (TMS) Safety Fire Pit
T200-9898-46 (Flex Connector)
Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.
Manual Gas Valve(ST3-080-1009) Mounting Nut
Thermocouple
Inlet Gas Supply
Male Threads: Requires Compound or Tape
(No compound/tape on �ared �ttings)
48-86 (Fitting not supplied: ½” Flare
to 3/8” Male Thread Fitting)
U1-8C-S (Fitting)
Spur Burner
Fire Pit Pan
Knob
EXPANDED VIEW
THERMOCOUPLE MANUAL SAFETY (TMS)
16
IGNITION SYSTEMS
1. Press the ON button on the hand-held remote transmitter. You will hear the igniter
probe begin sparking for 15 seconds and the fire pit will ignite.
2. If the fire pit does not light the module will start to “beep” one time every second
indicating an ignition error. If this occurs press the OFF button on the transmitter
and repeat step 1.
3. If fire pit does not light after second try, turn main gas OFF, wait 5 minutes and
repeat steps 1-3.
HOW TO LIGHT
REV. 2-16-17TFS Expanded View
Valve Box: (Gas valve,control module
and wires inside)
Battery Pack
Expanded View of Thermocouple Flame Sense (TFS) Fire Pits
Thermocouple & Ground Wires
Black Wire
Flat Disc Pan
Spur Burner Ignition Hood
7⁄8” WasherBrass Nut
OAS-NG#(Burner Ori�ce)
½” Coupler
T-200-9898-46 (Flex Conector)
Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.
Orange Ignition Wire
(3) 7⁄8” Washers
Inlet Gas Supply
EXPANDED VIEW
THERMOCOUPLE FLAME SENSE (TFS)
17
INCOMING GAS LINEBATTERY PACK
VALVEBOX
IGNITOR CONNECTION
GAS FLEX LINE
TFS Wiring Diagram
4-21-16
OUTPILOT ADJ
INMAIN
PILOT
Battery Pack
Black (Ground)
GreenWhite
2-Brown
White
Black (-)
Red (+)
Black (4-Pin Connector)
Red
Red
Blac
kBl
ack
Learn AUX
Rem
ote/
OFF
VCS-5000MODTCModule
IS
(Ignitor)(Sensor)(Thermocouple Ground Wire)
Ignitor Assembly
TFS Wiring Diagram
Copper
Orange
Tan
POWER
Orange
Latching Solenoid-DC Motor Drive
Low Rate Set Screw
ROUND | SQUARE | DISC
LINEAR | L-SERIES
WHATS IN THE BOX?
OUTPILOT ADJ
INMAIN
PILOT
Battery Pack
Black (Ground)
GreenWhite
2-Brown
White
Black (-)
Red (+)
Black (4-Pin Connector)
Red
Red
Blac
kBl
ack
Learn AUX
Rem
ote/
OFF
VCS-5000MODTCModule
IS
(Ignitor)(Sensor)(Thermocouple Ground Wire)
Pilot AssemblyTFS Linear Wiring Diagram
Copper
Orange
Tan
POWER
Orange
Latching Solenoid-DC Motor Drive
Low Rate Set Screw
WHATS IN THE BOX?
VALVEBOX
PILOTCONNECTION
BATTERY PACK
INCOMINGGAS LINE
GAS FLEX LINE
NOTE: The battery box should not be located inside the stainless steel enclosure. The battery box must be installed in a NEMA 3R Enclosure. It needs to be readily accessible to the end user in order to perform maintenance.
NOTE: The battery box should not be located inside the stainless steel enclosure. The battery box must be installed in a NEMA 3R Enclosure. It needs to be readily accessible to the end user in order to perform maintenance.
18
ROUND BURNER SYSTEMS SPECIFICATIONS
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-19RBSTFS-N 22” 19 1/4" - 21 1/2" 19" 2 3/4" 12 3/4" 18" 16" 54"
FPB-19RBSTFS-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 12 3/4" 18" 16" 54"
FPB-25RBSTFS-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 12 3/4" 18" 19" 69"
FPB-25RBSTFS-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 12 3/4" 18" 19" 69"
FPB-29RBSTFS-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 12 3/4" 18" 19" 69"
FPB-29RBSTFS-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 12 3/4" 18" 19" 69"
FPB-33RBSTFS-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 12 3/4" 18" 19" 69"
FPB-33RBSTFS-P 36 1/4" 34" - 35 1/4" 33" 2 3/4” 12 3/4" 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
ROUND TFS SYSTEMS
MODEL FACTORY ORIFICEBTU OUTPUT
ON HIGHBTU OUTPUT
ON LOW
FPB-19RBSTFS-N #19 80,000 45,000
FPB-19RBSTFS-P #36 79,000 47,400
FPB-25RBSTFS-N #7 105,000 51,000
FPB-25RBSTFS-P #31 100,000 49,500
FPB-29RBSTFS-N #7 105,000 51,000
FPB-29RBSTFS-P #31 100,000 49,500
FPB-33RBSTFS-N #7 105,000 51,000
FPB-33RBSTFS-P #31 100,000 49,500
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
19
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-19RBSTMS-N 22” 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8” 15 1/2” 14” 57"
FPB-19RBSTMS-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8” 15 1/2” 14” 57"
FPB-25RBSTMS-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8” 18" 16” 54”
FPB-25RBSTMS-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8” 18" 16” 54”
FPB-29RBSTMS-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8” 18" 19" 69"
FPB-29RBSTMS-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8” 18" 19" 69"
FPB-33RBSTMS-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 6 5/8” 18" 19" 69"
FPB-33RBSTMS-P 36 1/4" 34" - 35 1/4" 33" 2 3/4” 6 5/8” 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-013.
ROUND STAINLESS STEEL TMS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-013
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTMS-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
14"
54"2 3/4" 18" 54"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#29 65,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,50065,00065,50065,00065,50065,000
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTMS-PFPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
6 5/8"
15 1/2"
16"16"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-19RBSTMS-P
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
FPB-19RBSTMS-NFPB-19RBSTMS-PFPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
LPK#41
LPK#41
LPK#41
6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"14"15 1/2"
28" 25 1/4" - 27 1/2" 25"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-013.
ROUND STAINLESS STEEL TMS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-013
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTMS-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
14"
54"2 3/4" 18" 54"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#29 65,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,50065,00065,50065,00065,50065,000
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTMS-PFPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
6 5/8"
15 1/2"
16"16"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-19RBSTMS-P
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
FPB-19RBSTMS-NFPB-19RBSTMS-PFPB-25RBSTMS-N
FPB-29RBSTMS-N
FPB-33RBSTMS-N
FPB-25RBSTMS-P
FPB-29RBSTMS-P
FPB-33RBSTMS-P
LPK#41
LPK#41
LPK#41
6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"14"15 1/2"
28" 25 1/4" - 27 1/2" 25"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.
FPB-19RBSTMS-N #29 65,500 LPK#41
FPB-19RBSTMS-P #41 65,000 -
FPB-25RBSTMS-N #29 65,500 LPK#41
FPB-25RBSTMS-P #41 65,000 -
FPB-29RBSTMS-N #29 65,500 LPK#41
FPB-29RBSTMS-P #41 65,000 -
FPB-33RBSTMS-N #29 65,500 LPK#41
FPB-33RBSTMS-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
ROUND TMS SYSTEMS
20
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-16RBSMT-N 18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 6 3/8" 15 1/2" 14" 57"
FPB-16RBSMT-P 18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 6 3/8" 15 1/2" 14" 57"
FPB-19RBSMT-N 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8" 18" 16" 54"
FPB-19RBSMT-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8" 18" 16" 54"
FPB-25RBSMT-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8" 18" 19" 69"
FPB-25RBSMT-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8" 18" 19" 69"
FPB-29RBSMT-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 19" 69"
FPB-29RBSMT-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 19" 69"
FPB-33RBSMT-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 6 5/8" 18" 19" 69"
FPB-33RBSMT-P 36 1/4" 34" - 35 1/4" 33” 2 3/4" 6 5/8" 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.
FPB-16RBSMT-N #35 45,000 LPK#47
FPB-16RBSMT-P #47 45,500 -
FPB-19RBSMT-N #29 65,000 LPK#41
FPB-19RBSMT-P #41 65,000 -
FPB-25RBSMT-N #29 65,000 LPK#41
FPB-25RBSMT-P #41 65,000 -
FPB-29RBSMT-N #29 65,000 LPK#41
FPB-29RBSMT-P #41 65,000 -
FPB-33RBSMT-N #29 65,000 LPK#41
FPB-33RBSMT-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
ROUND MT SYSTEMS
21
ROUND OPTIONAL ACCESSORIES
TFS OPTIONAL ACCESSORIESTM-R-AF1TX Wireless wall mount timer (30/60/120min)
1001D-AF1TX Wireless wall mount switch (On/Off)
1322WT Wireless wall mount switch (On/Off/High/Low)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT
Stainless Steel lids with brushed finished
TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate
label sticker and instructions. For use with FPB-19,25/29/33RBSTMS-N
MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery
MT OPTIONAL ACCESSORIESLPK#47 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label
sticker and instructions. For use with FPB-16RBSMT-N, 45,000 Btu
LPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-19/25/29/33RBSMT-N, 65,000 Btu
MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery
LIDS
Home/Pool automation transmitter system (works with most manufacturers systems)
WINDSHIELDS Tempered glass windshields
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
WS Wired wall mount switch (On/Off)
22
SQUARE BURNER SYSTEMS SPECIFICATIONS
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-20SBSTFS-N 22" X 22" 20 1/4" - 21 3/4" 20" 2 3/4" 12 3/4" 18" 16" 54"
FPB-20SBSTFS-P 22" X 22" 20 1/4" - 21 3/4" 20" 2 3/4" 12 3/4" 18" 16" 54"
FPB-26SBSTFS-N 28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 12 3/4" 18" 19" 69"
FPB-26SBSTFS-P 28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 12 3/4" 18" 19" 69"
FPB-32SBSTFS-N 34" X 34" 32 1/4" - 33 3/4" 32" 2 3/4" 12 3/4" 18" 19" 69"
FPB-32SBSTFS-P 34" X 34" 32 1/4" - 33 3/4" 32" 2 3/4" 12 3/4" 18" 19" 69"
FPB-38SBSTFS-N 40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 12 3/4" 18" 19" 69"
FPB-38SBSTFS-P 40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 12 3/4" 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
MODEL FACTORY ORIFICEBTU OUTPUT
ON HIGHBTU OUTPUT
ON LOW
FPB-20SBSTFS-N #19 80,000 48,000
FPB-20SBSTFS-P #36 79,000 47,400
FPB-26SBSTFS-N #7 105,000 51,000
FPB-26SBSTFS-P #31 100,000 49,500
FPB-32SBSTFS-N #7 105,000 51,000
FPB-32SBSTFS-P #31 100,000 49,500
FPB-38SBSTFS-N #7 105,000 51,000
FPB-38SBSTFS-P #31 100,000 49,500
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
SQUARE TFS SYSTEMS
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
23
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-20SBSTMS-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"
FPB-20SBSTMS-P 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"
FPB-26SBSTMS-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”
FPB-26SBSTMS-P 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”
FPB-32SBSTMS-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19” 69"
FPB-32SBSTMS-P 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19" 69"
FPB-38SBSTMS-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 19" 69"
FPB-38SBSTMS-P 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4” 6 5/8” 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.
SQUARE STAINLESS STEEL TMS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-026
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,50065,00065,50065,00065,50065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTMS-N
FPB-32SBSTMS-N
FPB-38SBSTMS-N
FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSTMS-P
FPB-26SBSTMS-P
FPB-32SBSTMS-P
FPB-38SBSTMS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.
SQUARE STAINLESS STEEL TMS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-026
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,50065,00065,50065,00065,50065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTMS-N
FPB-32SBSTMS-N
FPB-38SBSTMS-N
FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSTMS-P
FPB-26SBSTMS-P
FPB-32SBSTMS-P
FPB-38SBSTMS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.
SQUARE STAINLESS STEEL TMS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-026
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,500
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,50065,00065,50065,00065,50065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTMS-N
FPB-32SBSTMS-N
FPB-38SBSTMS-N
FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSTMS-P
FPB-26SBSTMS-P
FPB-32SBSTMS-P
FPB-38SBSTMS-P
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.
FPB-20SBSTMS-N #29 65,500 LPK#41
FPB-20SBSTMS-P #41 65,000 -
FPB-26SBSTMS-N #29 65,500 LPK#41
FPB-26SBSTMS-P #41 65,000 -
FPB-32SBSTMS-N #29 65,500 LPK#41
FPB-32SBSTMS-P #41 65,000 -
FPB-38SBSTMS-N #29 65,500 LPK#41
FPB-38SBSTMS-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
SQUARE TMS SYSTEMS
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
24
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-20SBSMT-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"
FPB-20SBSMT-P 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"
FPB-26SBSMT-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”
FPB-26SBSMT-P 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”
FPB-32SBSMT-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19” 69"
FPB-32SBSMT-P 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19" 69"
FPB-38SBSMT-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 19" 69"
FPB-38SBSMT-P 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4” 6 5/8” 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.
SQUARE STAINLESS STEEL MT BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-030
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,00065,00065,00065,00065,00065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSMT-N
FPB-32SBSMT-N
FPB-38SBSMT-N
FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSMT-P
FPB-26SBSMT-P
FPB-32SBSMT-P
FPB-38SBSMT-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.
SQUARE STAINLESS STEEL MT BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-030
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,00065,00065,00065,00065,00065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSMT-N
FPB-32SBSMT-N
FPB-38SBSMT-N
FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSMT-P
FPB-26SBSMT-P
FPB-32SBSMT-P
FPB-38SBSMT-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.
SQUARE STAINLESS STEEL MT BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-030
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,00065,00065,00065,00065,00065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSMT-N
FPB-32SBSMT-N
FPB-38SBSMT-N
FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSMT-P
FPB-26SBSMT-P
FPB-32SBSMT-P
FPB-38SBSMT-P
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.
FPB-20SBSMT-N #29 65,500 LPK#41
FPB-20SBSMT-P #41 65,000 -
FPB-26SBSMT-N #29 65,500 LPK#41
FPB-26SBSMT-P #41 65,000 -
FPB-32SBSMT-N #29 65,500 LPK#41
FPB-32SBSMT-P #41 65,000 -
FPB-38SBSMT-N #29 65,500 LPK#41
FPB-38SBSMT-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
SQUARE MT SYSTEMS
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-022.
SQUARE STAINLESS STEEL TFS BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-022
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"
18"18"
19"19"
48,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSTFS-N
FPB-32SBSTFS-N
FPB-38SBSTFS-N
FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P
FPB-20SBSTFS-P
FPB-26SBSTFS-P
FPB-32SBSTFS-P
FPB-38SBSTFS-P
25
TFS OPTIONAL ACCESSORIES
TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating
plate label sticker and instructions. For use with FPB-20/26/32/38SBSMT-N, 65,000 Btu
MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery
MT OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating
plate label sticker and instructions. For use with FPB-20/26/32/38SBSMT-N, 65,000 Btu
MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery
TM-R-AF1TX Wireless wall mount timer (30/60/120min)
1001D-AF1TX Wireless wall mount switch (On/Off)
1322WT Wireless wall mount switch (On/Off/High/Low)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
SQUARE OPTIONAL ACCESSORIES
WS Wired wall mount switch (On/Off)
26
FLAT DISC BURNER SYSTEMS SPECIFICATIONS
MODEL
OUTSIDE DIM.
A
HEIGHT OF SPUR
B
DIM. FROM BOTTOM OF DISC TO BOTTOM
OF APPLIANCEC
CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN
D
CLEARANCE TO A COMBUSTABLE
SIDEWALLE
CLEARANCE TO A COMBUSTABLE
CEILINGF
FPB-29DBSTFS-N 29” 1" 10 1/4” 18" 19" 69"
FPB-29DBSTFS-P 29” 1” 10 1/4” 18" 19" 69"
FPB-34DBSTFS-N 34” 1" 10 1/4” 18" 19" 69"
FPB-34DBSTFS-P 34” 1” 10 1/4” 18" 19" 69"
FPB-44DBSTFS-N 44” 1” 10 1/4” 18" 19" 69"
FPB-44DBSTFS-P 44” 1” 10 1/4” 18" 19" 69"
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.
FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-034
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#7 105,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#31#7#31
100,000105,000100,000
A
B
A
C
D
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
18"18"
19"19"
51,000
BTU OUTPUTON LOW
49,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
10 1/4"10 1/4"10 1/4"
FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
69"69"
FPB-44DBSTFS-N
FPB-34DBSTFS-P
FPB-44DBSTFS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.
FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-034
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#7 105,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#31#7#31
100,000105,000100,000
A
B
A
C
D
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
18"18"
19"19"
51,000
BTU OUTPUTON LOW
49,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
10 1/4"10 1/4"10 1/4"
FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
69"69"
FPB-44DBSTFS-N
FPB-34DBSTFS-P
FPB-44DBSTFS-P
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.
FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-034
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#7 105,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#31#7#31
100,000105,000100,000
A
B
A
C
D
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
18"18"
19"19"
51,000
BTU OUTPUTON LOW
49,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
10 1/4"10 1/4"10 1/4"
FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P
69"69"
FPB-44DBSTFS-N
FPB-34DBSTFS-P
FPB-44DBSTFS-P
MODEL FACTORY ORIFICEBTU OUTPUT
ON HIGHBTU OUTPUT
ON LOW
FPB-29DBSTFS-N #7 105,000 51,000
FPB-29DBSTFS-P #31 100,000 49,500
FPB-34DBSTFS-N #7 105,000 51,000
FPB-34DBSTFS-P #31 100,000 49,500
FPB-44DBSTFS-N #7 105,000 51,000
FPB-44DBSTFS-P #31 100,000 49,500
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
DISC TFS SYSTEMS
2-inch minimum overlap per side required to secure disc
B
CD
E
F
27
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-036.
FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-036
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
69"69"
FPB-44DBSTMS-N
FPB-34DBSTMS-P
FPB-44DBSTMS-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-036.
FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-036
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
69"69"
FPB-44DBSTMS-N
FPB-34DBSTMS-P
FPB-44DBSTMS-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-036.
FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-036
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSTMS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P
69"69"
FPB-44DBSTMS-N
FPB-34DBSTMS-P
FPB-44DBSTMS-P
3 7/8"3 7/8"3 7/8"
LPK#41
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.
FPB-29DBSTMS-N #29 65,500 LPK#41
FPB-29DBSTMS-N #41 65,500 -
FPB-34DBSTMS-N #29 65,500 LPK#41
FPB-34DBSTMS-P #41 65,000 -
FPB-44DBSTMS-N #29 65,500 LPK#41
FPB-44DBSTMS-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
MODEL
OUTSIDE DIM.
A
HEIGHT OF SPUR
B
DIM. FROM BOTTOM OF DISC TO BOTTOM
OF APPLIANCEC
CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN
D
CLEARANCE TO A COMBUSTABLE
SIDEWALLE
CLEARANCE TO A COMBUSTABLE
CEILINGF
FPB-29DBSTMS-N 29” 1" 3 7/8” 18" 19" 69"
FPB-29DBSTMS-P 29” 1” 3 7/8” 18" 19" 69"
FPB-34DBSTMS-N 34” 1" 3 7/8” 18" 19" 69"
FPB-34DBSTMS-P 34” 1” 3 7/8” 18" 19" 69"
FPB-44DBSTMS-N 44” 1” 3 7/8” 18" 19" 69"
FPB-44DBSTMS-P 44” 1” 3 7/8” 18" 19" 69"
DISC TMS SYSTEMS
2-inch minimum overlap per side required to secure disc
B
CD
E
F
28
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.
FPB-29DBSMT-N #29 65,500 LPK#41
FPB-29DBSMT-P #41 65,000 -
FPB-34DBSMT-N #29 65,500 LPK#41
FPB-34DBSMT-P #41 65,000 -
FPB-44DBSMT-N #29 65,500 LPK#41
FPB-44DBSMT-P #41 65,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
MODEL
OUTSIDE DIM.
A
HEIGHT OF SPUR
B
DIM. FROM BOTTOM OF DISC TO BOT-
TOM OF APPLIANCEC
CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN
D
CLEARANCE TO A COMBUSTABLE
SIDEWALLE
CLEARANCE TO A COMBUSTABLE
CEILINGF
FPB-29DBSMT-N 29” 1" 3 7/8” 18" 19" 69"
FPB-29DBSMT-P 29” 1” 3 7/8” 18" 19" 69"
FPB-34DBSMT-N 34” 1" 3 7/8” 18" 19" 69"
FPB-34DBSMT-P 34” 1” 3 7/8” 18" 19" 69"
FPB-44DBSMT-N 44” 1” 3 7/8” 18" 19" 69"
FPB-44DBSMT-P 44” 1” 3 7/8” 18" 19" 69"
DISC MT SYSTEMS
2-inch minimum overlap per side required to secure disc
B
CD
E
F
29
FLAT DISC OPTIONAL ACCESSORIES
TFS OPTIONAL ACCESSORIES
TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate
label sticker and instructions. For use with FPB-29,34,44DBSTMS-N, 65,000 Btu
MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit. Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery
MT OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate
label sticker and instructions. For use with FPB-29,34/44DBSMT-N, 65,000 Btu
MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery
TM-R-AF1TX Wireless wall mount timer (30/60/120min)
1322WT Wireless wall mount switch (On/Off/High/Low)
1001D-AF1TX Wireless wall mount switch (On/Off)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
WS Wired wall mount switch (On/Off)
30
L SERIES BURNER SYSTEMS SPECIFICATIONS
5053-041
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.
LINEAR TFS BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.
FPB-L24TFS-N
LP GAS:
15" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24TFS-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#38 53K 20K LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#35#47
0.125"#43
35K 22K42K 23K42K 30K55K 37K55K 37K
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
8 1/2" 5 3/4"
6 1/4"
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"
FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
FPB-L30TFS-N
FPB-L36TFS-N
FPB-L24TFS-P
FPB-L30TFS-P
FPB-L36TFS-P
5053-041
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.
LINEAR TFS BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.
FPB-L24TFS-N
LP GAS:
15" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24TFS-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#38 53K 20K LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#35#47
0.125"#43
35K 22K42K 23K42K 30K55K 37K55K 37K
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
8 1/2" 5 3/4"
6 1/4"
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"
FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
FPB-L30TFS-N
FPB-L36TFS-N
FPB-L24TFS-P
FPB-L30TFS-P
FPB-L36TFS-P
MODEL
OVERALL LENGTH OF
CRADLEA
OVERALL WIDTH OF CRADLE
B
MIN/MAX CUT OUT LENGTH
C
MIN/MAX CUT OUT LENGTH
D
INSIDE PAN LENGTH
E
INSIDE PAN WIDTH
FPAN DEPTH
G
OVERALL HEIGHT OF APPLIANCE
H
FPB-24LTFS-N 28 1/4” 6 7/8" 28 1/2” 7 1/8" 24” 6 3/8” 4 1/4” 12 3/4"
FPB-24LTFS-P 28 1/4” 6 7/8" 28 1/2” 7 1/8” 24” 6 3/8” 4 1/4” 12 3/4”
FPB-30LTFS-N 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 12 3/4”
FPB-30LTFS-P 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 12 3/4”
FPB-36LTFS-N 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 12 3/4”
FPB-36LTFS-P 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 12 3/4”
5053-041
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.
LINEAR TFS BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.
FPB-L24TFS-N
LP GAS:
15" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24TFS-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#38 53K 20K LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#35#47
0.125"#43
35K 22K42K 23K42K 30K55K 37K55K 37K
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
8 1/2" 5 3/4"
6 1/4"
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"
FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P
FPB-L30TFS-N
FPB-L36TFS-N
FPB-L24TFS-P
FPB-L30TFS-P
FPB-L36TFS-P
MODEL FACTORY ORIFICEBTU OUTPUTHIGH LOW
CONVERSION KIT PART NO.
FPB-24LTFS-N #38 35K 20K LPK#50
FPB-24LTFS-P #50 35K 22K -
FPB-30LTFS-N #35 42K 23K LPK#48
FPB-30LTFS-P #47 42K 30K -
FPB-36LTFS-N 0.125” 55K 37K LPK#44
FPB-36LTFS-P #43 55K 37K -
BTU SPECS
PRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
L SERIES TFS SYSTEMS
31
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
MODEL
OVERALL LENGTH OF
CRADLEA
OVERALL WIDTH OF CRADLE
B
MIN/MAX CUT OUT LENGTH
C
MIN/MAX CUT OUT LENGTH
D
INSIDE PAN LENGTH
E
INSIDE PAN WIDTH
FPAN DEPTH
G
OVERALL HEIGHT OF APPLIANCE
H
FPB-24LMT-N 28 1/4” 6 7/8" 28 1/2” 7 1/8" 24” 6 3/8” 4 1/4” 4 3/4"
FPB-24LMT-P 28 1/4” 6 7/8" 28 1/2” 7 1/8” 24” 6 3/8” 4 1/4” 4 3/4”
FPB-30LMT-N 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 4 3/4”
FPB-30LMT-P 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 4 3/4”
FPB-36LMT-N 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 4 3/4”
FPB-36LMT-P 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 4 3/4”
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.
FPB-24LMT-N #42 35,000 LPK#50
FPB-24LMT-P #50 35,000 -
FPB-30LMT-N #38 45,000 LPK#48
FPB-30LMT-P #48 45,000 -
FPB-36LMT-N #32 55,000 LPK#44
FPB-36LMT-P #44 55,000 -
BTU SPECS
PRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
L SERIES MT SYSTEMS
32
COMBINING THE L SERIES
Bring the two ends together that you removed the brackets from
Locate and remove the extension bracket on both burners
Connecting two (2) MT units
Connecting two (2) TFS units
33
Here are the possible combinations.
Model + Model = Minimum Rough Opening Total BTU’s NG Total BTU’s LPFPB-36LTFS + FPB-36LTFS = 76.25” long x 7 1/8” wide 110,000 110,000
FPB-36LMT + FPB-36LMT = 76.25” long x 7 1/8” wide 104,000 104,000
FPB-36LTFS + FPB-30LTFS = 70.25” long x 7 1/8” wide 97,000 97,000
FPB-36LMT + FPB-30LMT = 70.25” long x 7 1/8” wide 97,000 100,000
FPB-36LTFS + FPB-24LTFS = 64.25” long x 7 1/8” wide 90,000 90,000
FPB-36LMT + FPB-24LMT = 64.25” long x 7 1/8” wide 87,000 90,000
FPB30LTFS + FPB30LTFS = 64.25” long x 7 1/8” wide 84,000 84,000
FPB30LMT + FPB30LMT = 64.25” long x 7 1/8” wide 90,000 90,000
FPB30LTFS + FPB24LTFS = 56.25” long x 7 1/8” wide 77,000 77,000
FPB30LMT + FPB24LMT = 56.25” long x 7 1/8” wide 80,000 80,000
FPB-24LTFS + FPB-24LTFS = 52.25” long x 7 1/8” wide 70,000 70,000
L SERIES OPTIONAL ACCESSORIES
LPK#50 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-24LMT-N, 40,000 Btu
LPK#48 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-30LMT-N, 47,000 Btu
LPK#44 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-36LMT-N, 60,000 Btu
TRIM-L24 3/4” stainless steel decorative trim fits FPB-24L Series
TRIM-L30 3/4” stainless steel decorative trim fits FPB-30L Series
TRIM-L36 3/4” stainless steel decorative trim fits FPB-36L Series
TRIM-L48 3/4” stainless steel decorative trim fits (2) FPB-24L Series end to end
TRIM-L60 3/4” stainless steel decorative trim fits (2) FPB-30L Series end to end
TRIM-L72 3/4” stainless steel decorative trim fits (2) FPB-36L Series end to end
TM-R-AF1TX Wireless wall mount timer (30/60/120min)
1001D-AF1TX Wireless wall mount switch (On/Off)
1322WT Wireless wall mount switch (On/Off/High/Low)
AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems
AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)
LIDS Stainless Steel lids with brushed finished
WINDSHIELDS Tempered glass windshields
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
WS Wired wall mount switch (On/Off)
TRIM (OPTIONAL ACCESSORY)
The clearance to combustible material for combined burners is the same as each individual burner. Please refer to individual burner list for clearance to combustible material
WIRING A SWITCH TO COMBINED BURNERS
MODULE MODULE
OFF
CONNECTION CONNECTION
When wiring (2) two L Series burners to the same switch, a two-pole switch is required (refer to diagram as an example). Maximum length 50’ of 18 gauge or larger wire, suitable for outdoor appliances - always refer to your local codes.
Access control module from the valve box and locate the brown wires.
Slide the switch on the control module from Remote to Off.
Connect the two brown wires to the 18 (or larger) gauge wire by connecting to the 1/4” terminals on the brown wires.
Connect the other end of the wire to one side of the two-pole switch.
34
NON-LISTED BURNER SYSTEMS SPECIFICATIONS
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-19RBS16MT-N 22” 19 1/4” - 21 1/2” 19" 2 3/4" 6 5/8" 18” 36” 96"
FPB-25RBS22MT-N 28” 25 1/4" - 27 1/2" 25" 2 3/4” 6 5/8" 18" 36” 96”
FPB-29RBS22MT-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 36” 96”
FPB-33RBS31MT-N 36 1/4” 34” - 35 1/4” 33" 2 3/4" 6 5/8" 18" 36” 96”
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
MODEL FACTORY ORIFICE BTU OUTPUT CONVERSION
FPB-19RBS16MT-N #31 60,000 OAS-LP45
FPB-19RBS16MT-P #45 55,500 -
FPB-25RBS22MT-N #22 100,000 OAS-LP35
FPB-25RBS22MT-P #35 99,000 -
FPB-29RBS22MT-N #22 100,000 OAS-LP35
FPB-29RBS22MT-P #35 99,000 -
FPB-33RBS31MT-N #08 160,000 OAS-LP29
FPB-33RBS31MT-P #29 150,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NON-LISTEDROUND MT SYSTEMS
OAS-LP45 Propane Conversion Kit (Orifice/Air Shutter) for 16” Burning Spur, 55,000 Btu
OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu
OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
OPTIONAL ACCESSORIES
These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.
35
MODEL
OUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAX CUT OUT DIM.
B
INSIDE PAN DIM.
C
PAN DEPTH
D
OVERALL APPLIANCE
HEIGHTE
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
F
CLEARANCE TO A
COMBUSTABLE SIDEWALL
G
CLEARANCE TO A
COMBUSTABLE CEILING
H
FPB-20SBS16MT-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 36” 96"
FPB-26SBS22MT-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 36” 96”
FPB-32SBS31MT-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 36” 96”
FPB-38SBS36MT-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 36” 96”
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.
SQUARE STAINLESS STEEL MT BURNER SYSTEMS
SQUARE BURNER SYSTEMS
5053-030
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-20SBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"
16"
69"26" 2 3/4" 18"
16"
69"34" X 34" 32" 2 3/4" 18" 19" 69"
32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"
38" 2 3/4" 18" 19" 69"
#29 65,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT
#41#29#41#29#41#29#41
65,00065,00065,00065,00065,00065,00065,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
32 1/4" - 33 3/4"
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-26SBSMT-N
FPB-32SBSMT-N
FPB-38SBSMT-N
FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
22" X 22"
28" X 28"
34" X 34"
40" X 40"
20 1/4" - 21 3/4"
26 1/4" - 27 3/4"
38 1/4" - 39 3/4"
32 1/4" - 33 3/4"
2 3/4"2 3/4"
FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P
6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"
LPK#41
LPK#41
LPK#41
FPB-20SBSMT-P
FPB-26SBSMT-P
FPB-32SBSMT-P
FPB-38SBSMT-P
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.
FPB-20SBS16MT-N #31 60,000 OAS-LP45
FPB-20SBS16MT-P #45 55,000 -
FPB-26SBS22MT-N #22 100,000 OAS-LP35
FPB-26SBS22MT-P #35 99,000 -
FPB-32SBS31MT-N #08 160,000 OAS-LP29
FPB-32SBS31MT-P #41 150,000 -
FPB-38SBS36MT-N #03 183,000 OAS-LP25
FPB-38SBS36MT-P #41 182,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
NON-LISTEDSQUARE MT SYSTEMS
OAS-LP45 Propane Conversion Kit (Orifice/Air Shutter) for 16” Burning Spur, 55,000 Btu
OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu
OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu
OAS-LP25 Propane Conversion Kit (Orifice/Air Shutter) for 36” Burning Spur, 182,000 Btu
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
OPTIONAL ACCESSORIES
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.
ROUND STAINLESS STEEL MT BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-017
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
TOP VIEW
FPB-16RBSMT-N
LP GAS:
FPB-16RBSMT-P
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"
19 1/4" - 21 1/2"
25 1/4" - 27 1/2"
30" - 31 3/8"
34" - 35 1/4"
FPB-19RBSMT-N FPB-19RBSMT-P
FPB-25RBSMT-N FPB-25RBSMT-P
FPB-29RBSMT-N FPB-29RBSMT-P
FPB-33RBSMT-N FPB-33RBSMT-P
FPB-16RBSMT-N #35 45,000 LPK#47
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUT CONVERSION
FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P
#47#29#41#29#41#29#41#29#41
45,50065,00065,00065,00065,00065,00065,00065,00065,000
LPK#41
LPK#41
LPK#41
LPK#41
AC
CBA
DE
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.
36
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-039.
FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS
FLAT DISC BURNER SYSTEMS
5053-039
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-34DBSMT-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE
DIM.A
MIN - MAXSPUR VIEW DIM.
B
HEIGHTOF SPUR
C
DIM. FROM BOTTOMOF DISC TO BOTTOM
OF APPLIANCED
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
34" 24" - 34" 1"44" 24" - 44" 1" 18"
19"
69"44" 1" 18"
19"
69"24" - 44"
#29 65,500
MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT
#41#29#41
65,00065,50065,000
A
BA
C
D
MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
18"18"
19"19"
LPK#41
CONVERSIONKIT PART NO.
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P
69"69"
FPB-44DBSMT-N
FPB-34DBSMT-P
FPB-44DBSMT-P
3 7/8"3 7/8"3 7/8"
LPK#41
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.
FPB-29DBS22MT-N #22 100,000 OAS-LP35
FPB-29DBS22MT-P #35 99,000 -
FPB-34DBS22MT-N #22 100,000 OAS-LP35
FPB-34DBS22MT-P #35 99,000 -
FPB-34DBS31MT-N #08 160,000 OAS-LP29
FPB-34DBS31MT-P #29 150,000 -
FPB-44DBS36MT-N #03 183,000 OAS-LP25
FPB-44DBS36MT-P #25 182,000 -
BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.
ROUND STAINLESS STEEL TFS BURNER SYSTEMS
ROUND BURNER SYSTEMS
5053-009
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
SELECT DESIRED SYSTEM:
NATURAL GAS:
FRONT VIEW
TOP VIEW
FPB-19RBSTFS-N
LP GAS:
F
G
H
CLEARANCE TO COMBUSTIBLES
FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOUTSIDE DIM.
(INCLUDING LIP)A
MIN - MAXCUT OUT DIM.
B
INSIDEPAN DIM.
C
PANDEPTH
D
OVERALLAPPLIANCE
HEIGHTE
CLEARANCE TO ACOMBUSTIBLE FLOOR
FROM THE LIP OF THE PANF
CLEARANCE TO ACOMBUSTIBLE
SIDEWALLG
CLEARANCE TOA COMBUSTIBLE
CEILINGH
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"
16"
69"
32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"
36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"
#19 80,000
MODEL BTUSPECIFICATIONS
FACTORY ORFICEBTU OUTPUT
ON HIGH
#36#7#31#7#31#7#31
79,000105,000100,000105,000100,000105,000100,000
AC
CBA
D
E
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
FPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
32 1/4"
36 1/4"
30" - 31 3/8"30" - 31 3/8"
34" - 35 1/4"
12 3/4"
12 3/4"12 3/4"12 3/4"12 3/4"
18"
19"
FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
45,000
BTU OUTPUTON LOW
47,40051,00049,50051,00049,50051,00049,500
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
FPB-25RBSTFS-N
FPB-29RBSTFS-N
FPB-33RBSTFS-N
FPB-19RBSTFS-P
FPB-25RBSTFS-P
FPB-29RBSTFS-P
FPB-33RBSTFS-P
12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"
28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"
MODEL
OUTSIDE DIM.
A
MIN - MAXSPUR VIEW DIM.
B
HEIGHT OF SPUR
C
DIM. FROM BOTTOM OF DISC TO BOTTOM OF
APPLIANCED
CLEARANCE TO A COMBUSTABLE
FLOOR FROM THE LIP OF PAN
E
CLEARANCE TO A COMBUSTABLE
SIDEWALLF
CLEARANCE TO A
COMBUSTABLE CEILING
G
FPB-29DBS22MT-N 29” 24” - 34” 1" 3 7/8” 18" 36” 96”
FPB-34DBS22MT-N 34” 24” - 34” 1" 3 7/8” 18" 36” 96”
FPB-34DBS31MT-N 34” 24” - 34” 1" 3 7/8” 18" 36” 96”
FPB-44DBS36MT-N 44” 24” - 44” 1” 3 7/8” 18" 36” 96”
NON-LISTEDDISC MT SYSTEMS
OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu
OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu
OAS-LP25 Propane Conversion Kit (Orifice/Air Shutter) for 36” Burning Spur, 182,000 Btu
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
OPTIONAL ACCESSORIES
E
F
G
These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.
37
NON-LISTEDLINE OF FIRE SYSTEMS
5053-056
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.
LINE OF FIRE MT/MSI
LINE OF FIRE
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
LOF30MT-N
6" FLOORTO BOTTOM
OF PAN
36"SIDEWALL
96" CEILING
CLEARANCE TO COMBUSTIBLES
LOF30MT-N 32 1/4"
MODELOVERALL
LENGTH OF PANA
OVERALLWIDTH OF PAN
B
INSIDE PANLENGTH
C
INSIDE PANWIDTH
D
MIN/MAX CUTOUT LENGTH
E
MIN/MAX CUTOUT WIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#36 45,000 OAS-LP49
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#29#36#29
75,00045,00075,000
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
END VIEWSIDE VIEW
TOP VIEW
8" 30"
30"
6" 30 1/4"
30 1/4"
6 1/2" 2 3/4"
32 1/4"
4"LOF36MT-NLOF30MSI-NLOF36MSI-N
38 1/4" 36"
36"
28 1/2"
34 1/2"38 1/4"
8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"
LOF36MT-N
LOF30MSI-N
3"
G H
DC
F B
E
A
LOF36MSI-N
LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N
OAS-LP41OAS-LP49OAS-LP41
60°
5053-056
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.
LINE OF FIRE MT/MSI
LINE OF FIRE
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
LOF30MT-N
6" FLOORTO BOTTOM
OF PAN
36"SIDEWALL
96" CEILING
CLEARANCE TO COMBUSTIBLES
LOF30MT-N 32 1/4"
MODELOVERALL
LENGTH OF PANA
OVERALLWIDTH OF PAN
B
INSIDE PANLENGTH
C
INSIDE PANWIDTH
D
MIN/MAX CUTOUT LENGTH
E
MIN/MAX CUTOUT WIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#36 45,000 OAS-LP49
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#29#36#29
75,00045,00075,000
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
END VIEWSIDE VIEW
TOP VIEW
8" 30"
30"
6" 30 1/4"
30 1/4"
6 1/2" 2 3/4"
32 1/4"
4"LOF36MT-NLOF30MSI-NLOF36MSI-N
38 1/4" 36"
36"
28 1/2"
34 1/2"38 1/4"
8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"
LOF36MT-N
LOF30MSI-N
3"
G H
DC
F B
E
A
LOF36MSI-N
LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N
OAS-LP41OAS-LP49OAS-LP41
60°
5053-056
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.
LINE OF FIRE MT/MSI
LINE OF FIRE
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
LOF30MT-N
6" FLOORTO BOTTOM
OF PAN
36"SIDEWALL
96" CEILING
CLEARANCE TO COMBUSTIBLES
LOF30MT-N 32 1/4"
MODELOVERALL
LENGTH OF PANA
OVERALLWIDTH OF PAN
B
INSIDE PANLENGTH
C
INSIDE PANWIDTH
D
MIN/MAX CUTOUT LENGTH
E
MIN/MAX CUTOUT WIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#36 45,000 OAS-LP49
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#29#36#29
75,00045,00075,000
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
END VIEWSIDE VIEW
TOP VIEW
8" 30"
30"
6" 30 1/4"
30 1/4"
6 1/2" 2 3/4"
32 1/4"
4"LOF36MT-NLOF30MSI-NLOF36MSI-N
38 1/4" 36"
36"
28 1/2"
34 1/2"38 1/4"
8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"
LOF36MT-N
LOF30MSI-N
3"
G H
DC
F B
E
A
LOF36MSI-N
LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N
OAS-LP41OAS-LP49OAS-LP41
60°
MODEL
OVERALL LENGTH OF
PANA
OVERALL WIDTH OF PAN
B
INSIDE PAN
LENGTHC
INSIDE PAN WIDTH
D
MIN/MAX CUT OUT LENGTH
E
MIN/MAX CUT OUT WIDTH
FPAN DEPTH
G
OVERALL HEIGHT OF APPLIANCE
H
LOF30MT-N 32 1/4” 8” 30” 6" 30 1/2” - 31 3/4” 6 1/4” - 7 1/2” 2 3/4” 4"
LOF36MT-N 38 1/4” 8” 36” 6” 36 1/2” - 37 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”
LOF30MSI-N 32 1/4” 8” 30” 6” 30 1/2” - 31 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”
LOF36MSI-N 38 1/4” 8” 36” 6” 36 1/2” - 37 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”
5053-056
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.
LINE OF FIRE MT/MSI
LINE OF FIRE
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
LOF30MT-N
6" FLOORTO BOTTOM
OF PAN
36"SIDEWALL
96" CEILING
CLEARANCE TO COMBUSTIBLES
LOF30MT-N 32 1/4"
MODELOVERALL
LENGTH OF PANA
OVERALLWIDTH OF PAN
B
INSIDE PANLENGTH
C
INSIDE PANWIDTH
D
MIN/MAX CUTOUT LENGTH
E
MIN/MAX CUTOUT WIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#36 45,000 OAS-LP49
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#29#36#29
75,00045,00075,000
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
END VIEWSIDE VIEW
TOP VIEW
8" 30"
30"
6" 30 1/4"
30 1/4"
6 1/2" 2 3/4"
32 1/4"
4"LOF36MT-NLOF30MSI-NLOF36MSI-N
38 1/4" 36"
36"
28 1/2"
34 1/2"38 1/4"
8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"
LOF36MT-N
LOF30MSI-N
3"
G H
DC
F B
E
A
LOF36MSI-N
LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N
OAS-LP41OAS-LP49OAS-LP41
60°
5053-043
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .
4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.
LINEAR MT BURNER SYSTEMS
LINEAR SERIES
SELECT DESIRED SYSTEM:
NATURAL GAS:
DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.
FPB-L24MT-N
LP GAS:
1" FLOORTO BOTTOMOF CRADLE
17"SIDEWALL
44" CEILING
CLEARANCE TO COMBUSTIBLES
FPB-L24MT-N 28 1/4"
THESE FIRE PITSARE TESTED TO
ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.
MODELOVERALL LENGTH
OF CRADLEA
OVERALL WIDTHOF CRADLE
B
MIN/MAXCUT OUTLENGTH
C
MIN/MAXCUT OUTLENGTH
D
INSIDE PANLENGTH
E
INSIDE PANWIDTH
F
PANDEPTH
G
OVERALL HEIGHTOF APPLIANCE
H
#42 35,000 LPK#50
MODEL BTUSPECIFICATIONS
FACTORY ORFICE BTU OUTPUTCONVERSION KIT
PART NO.
#50#38#48#32#44
35,00045,00045,00055,00055,000
LPK#48
LPK#44
MIN. INLET 5.0" WC 10.5" WC
PRESSURE GAS TYPE NG GAS TYPE LP
MAX. INLETNORMAL INLET
10.5" WC7.0" WC
13.0" WC11.0" WC
AC
B D
2" TYP.
23" TYP.
E
G
F
H
END VIEWSIDE VIEW
TOP VIEW
6 7/8" 28 1/2"
34 1/2"
40 1/2"
7 1/8" 24"
30"
36"
6 3/8" 4 1/4"
34 1/4"
40 1/4"
4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
28 1/4" 28 1/2"
34 1/2"
40 1/2"
24"
30"
36"
34 1/4"
40 1/4"
6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"
FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P
FPB-L30MT-N
FPB-L36MT-N
FPB-L24MT-P
FPB-L30MT-P
FPB-L36MT-P
MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.
LOF30MT-N #36 45,000 OAS-LP49
LOF36MT-N #29 75,000 OAS-LP41
LOF30MSI-N #36 45,000 OAS-LP49
LOF36MSI-N #29 75,000 OAS-LP41
BTU SPECS
PRESSURE GAS TYPE NG GAS TYPE LP
MIN. INLET 5.0" WC 10.5" WC
MAX. INLET 10.5" WC 13.0" WC
NORMAL INLET 7.0" WC 11.0" WC
GAS PRESSURE
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
OAS-LP49 Propane Conversion Kit (Orifice/Air Shutter) for LOF-30 Series. 43,000 Btu
OAS-LP41 Propane Conversion Kit (Orifice/Air Shutter) for LOF-36 Series. 65,000 Btu
LID-LOF30 Linear stainless steel lid with brushed finish for the LOF-30 Series
LID-LOF36 Linear stainless steel lid with brushed finish for the LOF-36 Series
VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws
OPTIONAL ACCESSORIES
These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.
38
AnF (Assemble and Finish) SPECIFICATIONS
ROUND SERIES
MODELOVERALL DIAMETER
A
OVERALL HEIGHT(TOP INSTALLED)
BMAXIMUM CUT OUT
C
ANF-R42 42 1/4” 18 5/8" 21"
ANF-R48 48 1/4” 18 5/8” 28 7/8"
ANF-R60 60 1/4” 18 5/8” 33 3/8"
A
C
B
AnF ROUND BURNER SYSTEM MATRIX
LINEAR SERIES
MODELLENGTH
A
HEIGHT(TOP INSTALLED)
BDEPTH
C
MAX CUT OUT WIDTH
D
MAX CUT OUT LENGTH
E
ANF-L48 48” 18 1/2” 24" 15 3/4” 44 1/2”
ANF-L66 66” 18 1/2” 24” 6 7/8” 62 1/2”
ANF-L74 74” 18 1/2” 24” 6 7/8” 70 1/2”
ANF-L96 96” 18 1/2” 24” 6 7/8” 89”
B
A
C
E
D
B
A
C
E
D
AnF LINEAR BURNER SYSTEM COMBINATION MATRIXAll single Linear fire pit burner systems fit all Linear AnF’s, and all Linear fire pit burner systems require supports.
FPB-36L + FPB-36LFPB-36L + FPB-30L
FPB-36L + FPB-24LFPB-30L + FPB-30L
FPB-30L + FPB-24LFPB-24L + FPB-24L
ANF-L66 ANF-L74 ANF-L96fits fits fits
16”ROUND
19”ROUND
20”SQUARE
25” ROUND
26”SQUARE
29”ROUND
32”SQUARE
33”ROUND
ANF-R42Does this pan fit this AnF? YES YES YES NO NO NO NO NO
Does it require supports? YES NO NO NO NO NO NO NO
ANF-R48Does this pan fit this AnF? NO YES YES YES YES NO NO NO
Does it require supports? NO YES YES NO NO NO NO NO
ANF-R60Does this pan fit this AnF? NO NO NO YES YES YES YES YES
Does it require supports? NO NO NO YES NO NO NO NO
39
AnF ROUND PACKAGES
ANFR42-19RTFS-N 42” Round AnF with a 19” Round TFS System (Natural Gas)
ANFR42-19RTFS-P 42” Round AnF with a 19” Round TFS System (Propane)
ANFR42-19RTMS-N 42” Round AnF with a 19” Round TMS System (Natural Gas)
ANFR42-19RMT-N 42” Round AnF with a 19” Round MT System (Natural Gas)
ANFR48-19RTFS-N 48” Round AnF with a 19” Round TFS System (Natural Gas)
ANFR48-19RTFS-P 48” Round AnF with a 19” Round TFS System (Propane)
ANFR48-19RTMS-N 48” Round AnF with a 19” Round TMS System (Natural Gas)
ANFR48-19RMT-N 48” Round AnF with a 19” Round MT System (Natural Gas)
AnF LINEAR PACKAGES
ANFL48-30LTFS-N 48” Linear AnF with a 30” L Series TFS System (Natural Gas)
ANFL48-30LTFS-P 48” Linear AnF with a 30” L Series TFS System (Propane)
ANFL48-30LMT-N 48” Linear AnF with a 30” L Series MT System (Natural Gas)
ANFL48-LOF30MT-N 48” Linear AnF with a 30” Line of Fire MT System (Natural Gas)
AnF ENCLOSURES & FIRE PIT BURNER COMBINATIONS
MODELLENGTH
A
HEIGHT(TOP INSTALLED)
B
MAX CUT OUT LENGTH
C
MAX CUT OUT DEPTH
D
ANF-S48 48” 18 1/2” 40 3/16” 44 1/2”
ANF-S60 60” 18 1/2” 52 3/16” 56 1/2”
SQUARE SERIES
B
A
C
D
B
A
C
D
All Fire Pit Burner Systems fit all square AnF’s, and all Fire Pit Burner Systems require supports
40
BURNER SPECIFICATIONS
KIT MODEL SINGLE MODELOVERALL WIDTH
AOVERALL HEIGHT
BORIFICE SIZE
NGBTU’S NG
ORIFICE SIZELP
BTU’S LP
DBS-12K DBS-12 12 1/8” 1 7/8" OAS-NG38 42,000 OAS-LP52 33,000
DBS-16K DBS-16 15 7/8” 1 7/8” OAS-NG31 60,000 OAS-LP45 55,000
DBS-22K DBS-22 22 1/16” 1 7/8” OAS-NG22 100,000 OAS-LP35 99,000
DBS-31K DBS-31 30 7/8” 1 7/8” OAS-NG08 160,000 OAS-LP29 150,000
DBS-36K DBS-36 35” 1 7/8” OAS-NG03 183,000 OAS-LP25 182,000
5053-079
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 06/09/2016
NOTES:1. DESIGNER BURNING SPURS (DBS) ARE INDIVIDUAL SPUR BURNERS FOR INSTALLATION INTO A CUSTOM DESIGNED FIRE PIT. INSTALLATION REQUIRES A METAL PAN (NOT SUPPLIED) TO BE USED UNDERNEATH THE BURNING SPUR PER APPLICATION. DBS BURNERS COME AS AN INDIVIDUAL SPUR SUPPLIED WITH A BURNER ORIFICE (I.E. DBS-12) OR AS A KIT (I.E. DBS-12K) SUPPLIED WITH A BURNER ORIFICE, FLEX CONNECTOR, KEY VALVE, POLISHED CHROME COVER AND A 8" POLISHED CHROME KEY.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
3. ALL INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A CUSTOM FIRE PIT WITH THE DBS BURNERS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER 5053-079.
BURNING SPUR & BURNING SPUR KITS
BURNING SPUR & BURNING SPUR KITS
SELECT DESIRED MODEL:
DBS-12K
DBS-16K
DBS-12 12 1/8" 1 7/8"
KIT MODELSINGLEMODEL
OVERALL WIDTHA
OVERALL HEIGHTB
TOP VIEW
DBS-22K
DBS-31K
DBS-12KDBS-16KDBS-22KDBS-31K
OAS-NG38
ORIFICE SIZENG
BTU'S NG
DISCLAIMER: BTU LISTINGS ARE BASED ON 7" WC FOR NATURAL GAS (NG) AND 11" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.
DBS-16DBS-22DBS-31
15 7/8" OAS-NG3122 1/16" OAS-NG2230 7/8" OAS-NG08
DBS-36K
ORIFICE SIZELP
BTU'S LP
42,000 OAS-LP52 33,00060,000 OAS-LP45 55,000
100,000 OAS-LP35 99,000160,000 OAS-LP29 150,000
DBS-36K DBS-36 35" OAS-NG03 183,000 OAS-LP25 182,000
DBS-12
DBS-16
DBS-22
DBS-31
DBS-36
1 7/8"1 7/8"1 7/8"1 7/8"
A
B
SIDE VIEW
BURNING SPUR
DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A
RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.
LIQUID PROPANE ORIFICE NATURAL GAS ORIFICE
41
FLEXFRAME SPECIFICATIONS
MODELS
FLEXFRAME-SS Constructed of 16 Gauge 304 Stainless Steel. Engineered to protect against outdoor elements including salt water environments - two (2) 44” pieces per package.
FEATURESFLEXFRAME-PC Constructed of Zinc Epoxy Coated 16 Gauge
Galvanized Steel. Engineered to protect against outdoor elements - two (2) 44” pieces per package
The Flexframe allows you to fill the gap between the inside opening and the burner pans or disc
The flexframe can be bent or cut to fit any shape (square, linear or round) fire pit.
Allows you to remove the burner system without removing any pavers
Example of the Flexframe in a round fire pit
Example of the Flexframe in a square/linear fire pit
42
PAVER KIT CONTROL PANELS SPECIFICATIONS
REV. 12-31-14 Page 1 of 7MT PAVER KITS
DESCRIPTION: The Paver Kit face plate bracket (control panel) is designed to install in conjunction with a typical Patio Block fire pit kit (purchased separately). It installs underneath the fire pit pan/disc in place of one patio block. The control panel itself provides a convenient location to house the gas valve and Piezo ignition (if applicable) then is easily removed for servicing.
This installation instruction covers two (2) separate kits: 1) PAVER-KIT-MT and 2) PAVER-KIT-MT-MSI.
DIMENSIONS: The Paver Kit bracket and extension will fit an opening with a maximum of 10.500” wide x 3.500” tall. Without the Bracket Extension plate the maximum width is 8.00” wide. The holes in the Extension Bracket are spaced every .500”.
10.500” Max.
8.00” Min.
3.500”
Fig 3. Paver Kit Control Panel Dimensions
Fig. 1 Paver kit with fire pit pan. Fig. 2. Paver kit with fire pit flat disc.
TOOLS NEEDED: (1) Drill/driver, Gas Rated Teflon Tape or Compound, 5/16” Hex head driver, (1) 3/16” Concrete Drill Bit, (2) Adjustable Wrenches, Assorted Open-end Wrenches
Table of Contents
Description Page 1
General Instructions Page 1 - 2
PAVER-KIT-MT Page 2 - 3
PAVER-KIT-MT-MSI Page 3 - 5
Warranty Page 6
Replacement Parts Page 7
PRECAUTION: If you are installing the MSI (Manual Spark Ignition) ensure the PAVER-KIT-MT-MSI control panel is with-in 40-inches of the 2-probe Piezo ignitor. This will allow enough “play” in the wires to make your connections. See Fig. 16 on page 5.
Round Fire Pit Pan Round Flat Fire Pit Disc
PAVER KIT MOUNTING BRACKETAll paver kit control panels come with the same paver mounting bracket.
PAVER KIT MT
REV. 12-31-14 Page 2 of 7 MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONSModels include: PAVER-KIT-MT & PAVER-KIT-MT-MSI
REV. 12-31-14 Page 3 of 7MT PAVER KITS
Paver BlockPaver Block
Fig. 7 Installing MT valve into control panel.
STEP 2: Once the 90° elbows are installed into the manual key valve then install the MT key valve bracket into Paver Kit control panel as shown in Fig. 7.
STEP 3: Secure the key valve bracket into place using the four black thread cutting screws. See Fig. 8.
STEP 4: Install the flex connector from the burner to either side of the gas valve and connect gas supply to the other side of the gas valve. Conduct a trial burn test by temporarily connecting the fire pit pan and burner and check for any gas leaks before completing the installation. See fire pit manual for proper connections.
See page 6 for lighting instructions.
STEP 5: After burn test is complete, finish the patio paver blocks installation.
PAVER KIT-MT-MSI INSTALLATION
CAUTION: Turn OFF gas supply before beginning installation. If the fire pit is already installed, remove all media before beginning installation.
Step 1: Prepare the fire pit pan or disc by first removing the two screws from the 1” x 2” metal cover plate exposing the rectangular hole then align the burner leg as shown in Fig. 9. The inside edge of the burner leg should be approximately 3/4-inch away from the inside edge of rectangular hole.
Step 2: Remove the two stainless steel screws and nuts from the probe assembly but leave it assembled. Carefully slide the orange wire from the top of the pan through rectangular hole in the fire pit pan resting over the burner leg and install the screws into the existing holes of the cover plate. See Fig. 10.
Cover Plate
Fig. 9 Removing cover plate from pan.
Fig. 8 Close up view securing MT valve bracket to control panel.
REV. 12-31-14 Page 3 of 7MT PAVER KITS
Paver BlockPaver Block
Fig. 7 Installing MT valve into control panel.
STEP 2: Once the 90° elbows are installed into the manual key valve then install the MT key valve bracket into Paver Kit control panel as shown in Fig. 7.
STEP 3: Secure the key valve bracket into place using the four black thread cutting screws. See Fig. 8.
STEP 4: Install the flex connector from the burner to either side of the gas valve and connect gas supply to the other side of the gas valve. Conduct a trial burn test by temporarily connecting the fire pit pan and burner and check for any gas leaks before completing the installation. See fire pit manual for proper connections.
See page 6 for lighting instructions.
STEP 5: After burn test is complete, finish the patio paver blocks installation.
PAVER KIT-MT-MSI INSTALLATION
CAUTION: Turn OFF gas supply before beginning installation. If the fire pit is already installed, remove all media before beginning installation.
Step 1: Prepare the fire pit pan or disc by first removing the two screws from the 1” x 2” metal cover plate exposing the rectangular hole then align the burner leg as shown in Fig. 9. The inside edge of the burner leg should be approximately 3/4-inch away from the inside edge of rectangular hole.
Step 2: Remove the two stainless steel screws and nuts from the probe assembly but leave it assembled. Carefully slide the orange wire from the top of the pan through rectangular hole in the fire pit pan resting over the burner leg and install the screws into the existing holes of the cover plate. See Fig. 10.
Cover Plate
Fig. 9 Removing cover plate from pan.
Fig. 8 Close up view securing MT valve bracket to control panel.
PAVER KIT TMSModels include: PAVER-KIT-TMS & PAVER-KIT-TMS-MSI
REV. 12-31-14 Page 2 of 9TMS PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws.
Fig. 4 Securing the control panel into the paver block.
Fig. 5 Control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
GENERAL INSTRUCTIONS
3/8” NPT Close Nipple
3/8” NPT Black Iron 90° Elbow
(U1-8C-S)1/2" OD Flare x
3/8" MIP
Piezo Ignitor Mounting Hole
Gas Inlet
Fig. 6 TMS valve fitting orientation.
With the paver kit face plate bracket (control panel) installed you are now ready to install the TMS gas valve.
STEP 1: Prepare the 3/8” close nipple and 1/2” OD Flare x 3/8” brass fittings by installing gas rated Teflon tape or compound to the male threads and install them into the TMS valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. The TMS valve comes with a 1/2” OD Flare x 3/8” brass fitting. Ensure you use this fitting to complete the installation. See figure 6 for proper orientation.
NOTE: Ensure to attach the flex connector from gas supply to the inlet side of the gas valve. Hard piping may also be installed in place of the flared connector.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
PAVER KIT-TMS INSTRUCTIONS
REV. 12-31-14 Page 3 of 9TMS PAVER KITS
STEP 2: Once the fittings are installed into the TMS valve then install the valve and bracket into Paver Kit control panel as shown in figure 7.
STEP 3: Secure the TMS valve bracket into place using the four black thread cutting screws. See Fig. 8.
STEP 4: Install the flex connector from the burner to outlet side of the gas valve and connect gas supply to the inlet side of the gas valve. Conduct a trial burn test and check for any gas leaks before completing the installation.
See page 7 for lighting instructions.
STEP 5: After burn test is complete, finish the patio paver block installation.
Paver BlockPaver Block
Fig. 7 Installing TMS valve into control panel.
PAVER KIT-MT-MSI INSTALLATION
Fig. 9 Removing screen cover from ignitor hood.
CAUTION: If the fire pit is installed then turn OFF main gas supply and remove all media prior to installation of MSI Kit.
Step 1: Prepare the fire pit pan by first removing the screen cover hood from the ignitor hood. See Fig.9.
Fig. 8 Close up view securing TMS valve bracket to control panel.
REV. 12-31-14 Page 3 of 9TMS PAVER KITS
STEP 2: Once the fittings are installed into the TMS valve then install the valve and bracket into Paver Kit control panel as shown in figure 7.
STEP 3: Secure the TMS valve bracket into place using the four black thread cutting screws. See Fig. 8.
STEP 4: Install the flex connector from the burner to outlet side of the gas valve and connect gas supply to the inlet side of the gas valve. Conduct a trial burn test and check for any gas leaks before completing the installation.
See page 7 for lighting instructions.
STEP 5: After burn test is complete, finish the patio paver block installation.
Paver BlockPaver Block
Fig. 7 Installing TMS valve into control panel.
PAVER KIT-MT-MSI INSTALLATION
Fig. 9 Removing screen cover from ignitor hood.
CAUTION: If the fire pit is installed then turn OFF main gas supply and remove all media prior to installation of MSI Kit.
Step 1: Prepare the fire pit pan by first removing the screen cover hood from the ignitor hood. See Fig.9.
Fig. 8 Close up view securing TMS valve bracket to control panel.
Front View Top View Finished Front View
Top View
Top View Angle View
Top View
Top View
Angle View
REV. 12-31-14 Page 2 of 7MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONS
REV. 12-31-14 Page 2 of 7MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONS
REV. 12-31-14 Page 2 of 7MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONS
REV. 12-31-14 Page 2 of 7MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONS
REV. 12-31-14 Page 2 of 7MT PAVER KITS
STEP 1: Determine the best location to install the paver kit control panel per your installation.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.
STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.
NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.
NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.
Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.
STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.
Fig. 4 Top view of control panel securing into the paver block.
Fig. 5 Front view of control panel installed, ready for valve bracket.
Paver BlockPaver Block
Place control panel into position, mark the two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.
STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.
NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.
CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.
½” Flare x ½” MIP 90° Brass Elbow
Manual Key Valve
½” Flare x ½” MIP 90° Brass
Elbow
Key Valve Flange
Piezo Ignitor Mounting Hole
Fig. 6 Manual key valve elbow orientation.
GENERAL INSTRUCTIONS
PAVER KIT-MT INSTRUCTIONS
43
MSI KITS FOR PAVER CONTROL PANELS
MT KEY VALVE
REV. 12-31-14 Page 6 of 9TMS PAVER KITS
Fig. 16 Removing plastic plug from mounting plate.
Fig. 18 Installing Piezo module into mounting plate.
3/8” NPT Close Nipple
3/8” NPT Black Iron 90° Elbow
(U1-8C-S)1/2" OD Flare x
3/8" MIP
Piezo Ignitor Mounting Hole
Gas Inlet
Fig. 19 Attaching Piezo ignition wires.
Step 8: Remove the black plastic plug from the valve mounting plate for preparation of installing the Piezoignition module. See Fig. 16.
Step 9: The Piezo module mounts directly to the TMS valve bracket. Install the Piezo module using the smaller hole with the two notches and slide module into the place until it stops. Using the plastic nut thread it onto the Piezo module to secure into place. Be careful not to turn the nut too tight and crack the plastic. Install the AAA battery as shown and thread the red button cap on the remaining threads of the module. See Fig. 17.
Step 10: Connect the 3/16” end of the PIEZO23WH extension wire and 3/16” end of the PIEZO48WH wire into the back side of the spark ignitor module. See Fig. 19 detail.
Step 11: Attach the 1/4” end of extension wire (PIEZO23WH) to the orange ignitor wire and attach the 1/4” wire end (PIEZO48WH) wire to ground tab under the burner pan. See figure drawings 14, 19 and 20 for reference.
Step 12: Reconnect the thermocouple lead to the gas valve. Install it finger tight plus a quarter turn with a wrench.
+ -AAA
Plastic Nut
Red Button Cap
Mounting Plate
Fig. 17 Installing battery into Piezo module.
PIEZO48WH
PIEZO23WH
Inlet
Thermocouple Lead
Outlet
PAVER-KIT-MT-MSI PAVER-KIT-TMS-MSI
REV. 12-31-14 Page 5 of 7MT PAVER KITS
Step 5: Install the ignition hood over top of the ignition probe assembly into the existing pre-punched holes of the burner pan by using the five #10 - 24 x ½” provided screws. See Fig. 14.
Step 6: Ensure the Paver kit control panel is within 40-inches of the 2-probe Piezo ignitor. This will allow enough “play” in the wires to make your connections. If not you may have to rotate the pan or disc to make proper connections.
Step 7: Connect the 3/16” end of the PIEZO23WH extension wire and 3/16” end of the PIEZO48WH wire into the back side of the spark ignitor module. See Fig. 15 detail.
Step 8: Attach the 1/4” end of extension wire (PIEZO23WH) to the orange ignitor wire and attach the 1/4” wire end (PIEZO48WH) wire to ground tab under the burner pan.See Fig. 16.
Step 9: Test the ignitor by pushing and holding the red button to ensure the 2-probe ignitor is sparking inside the ignition box in the burner pan. The spark should be located directly over top of the burner port hole for proper ignition of the gas as previously discussed. Spacing between the probes should be approximately 1/8” for proper spark. See Fig. 12 on page 4 if necessary.
Step 10: Install the ignition hood screen mesh and ensure no media lays on the screen mesh area. See Fig. 17. Install the lava rock/media material according to fire pit install manual and turn the main gas supply back ON. Installation is now complete.
Fig. 15 Wiring into the Piezo module.
Manual Key Valve
Gas Supply
Fire Pit PanProbe Assembly
Orange Wire
Piezo ModulePIEZO23WH
PIEZO48WH
ON
OFF
Lava RockLava Rock
Lava Rock
Ignition Hood
Ignition Hood Screen
Spur Burner Leg
Ignition Hood
Ignitor Probes
Rainshield
Fig. 14 Installing ignition hood.
Fig. 16 Wiring diagram Fig. 17 Installing screen mesh cover on ignitor hood.
PAVER VENT KITS
REV. 9-10-15 Page 2Paver Vents 4-6
DESCRIPTION: These vents are designed to be used with most paver block fire pit enclosures and can be installed as a universal vent for other applications such as grill islands, fire table or bars. The vents provided with this kit provide a minimum of 18-square inches per vent.
Many fire pits require a minimum of 18 square inches of cross ventilation (see Fig.1). This cross ventilation provides sev-eral things: 1. It allows fresh air to keep the enclosure dry and protect any electronic components to ensure they operate and function as designed. 2: It provides an outlet for possible gas leaks and can prevent any potential delayed ignitions. 3. It assist in keeping the enclosure cooler due to radiant heat that can occur during operation.
In some cases the extension bracket may be not needed because the vent can be recessed inside the blocks to help camouflage them. Two vents per fire pit are required on each side of enclosure to ensure cross ventilation.
ON
OFF
AT ON
POSITIO
N
SLIGH
T PUSH
TO
TURN
OFF
FULL PU
SH TO
LIGH
T
Cross Flow Ventilation
8”
3.5”
7”
3.12”
8”
5.5”
7”
5.12”
Fig. 2 PAVER-VENT - 4
Fig. 3 PAVER-VENT- 6
Fig. 1 Cross ventilation example
REV. 9-10-15 Page 2Paver Vents 4-6
DESCRIPTION: These vents are designed to be used with most paver block fire pit enclosures and can be installed as a universal vent for other applications such as grill islands, fire table or bars. The vents provided with this kit provide a minimum of 18-square inches per vent.
Many fire pits require a minimum of 18 square inches of cross ventilation (see Fig.1). This cross ventilation provides sev-eral things: 1. It allows fresh air to keep the enclosure dry and protect any electronic components to ensure they operate and function as designed. 2: It provides an outlet for possible gas leaks and can prevent any potential delayed ignitions. 3. It assist in keeping the enclosure cooler due to radiant heat that can occur during operation.
In some cases the extension bracket may be not needed because the vent can be recessed inside the blocks to help camouflage them. Two vents per fire pit are required on each side of enclosure to ensure cross ventilation.
ON
OFF
AT ON
POSITIO
N
SLIGH
T PUSH
TO
TURN
OFF
FULL PU
SH TO
LIGH
T
Cross Flow Ventilation
8”
3.5”
7”
3.12”
8”
5.5”
7”
5.12”
Fig. 2 PAVER-VENT - 4
Fig. 3 PAVER-VENT- 6
Fig. 1 Cross ventilation example
PAVER-VENT-4 PAVER-VENT-6
REV. 9-10-15 Page 4
PRECAUTION: The vent bracket is designed to be mounted to a paver block by drilling two holes and securing it into place with two concrete screws(provided). If you desire to place the vent in the first row of patio blocks you may need to install a block below grade level to secure the vent bracket into place.
At the same time, depending on how your are laying your paver blocks you may need to incorporate a lintel (not included) to lay across the top of the paver vent to support your next row of blocks. The reason for this is that the vent may support the front edge of a block but the back edge could easily fall without some type of additional support. We suggest using a rigid 3" x 12" metal plate (part # PAVER-VENT-LINTEL) to order one if needed.
STEP 1: Determine the best location to install the paver vent in your enclosure.
STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the vent bracket can be adjusted to fit various openings. NOTE: When installing it is recommended (but not required) to recess the vent bracket an inch or two to help camouflage the vent and keep it in a lower area of the enclosure. Vent can also be painted to match block if desired.
The bracket extension can be used to extend the vent bracket from 8-inches wide up to 10-inches wide if necessary. The holes in the bracket extension allow for 1/2" increments for width adjustment. Figure 5 shows the extension in the properly oriented position. If the extension bracket is installed and your are using any of the holes numbered 3 & 4, the perforated area should be bent and broken off (removed) to ensure you are not covering the vent bracket opening.
Paver BlockPaver Block
Top View of Vent Installed
Place the vent bracket into position, mark the two holes, remove vent bracket and drill two
holes with a 3/16” concrete drill bit.
Fig. 4 Top view of vent installed
Fig. 5 Extension bracket installed
STEP 3: After you have determined the location and measured the width, install the vent kit bracket and mark the two holes on the inside area of the bracket as shown in figure 3.
STEP 4: Drill the two holes with a 3/16” concrete drill bit and secure the paver vent bracket with the two concrete screws. Figure 5 shows front view.
Proper Orientation
1 2 3 4
1 2 3 4
Paver Vents 4-6
Top View Top View
Angle View
Front View
Front View
44
MEDIA INSTALL GUIDE
LAVA ROCK ONLYWhen using only lava rock, you only need to use as much lava rock in order to cover the burner. Do not over-fill. Just use enough to hide the burner from view.
LAVA ROCK
LAVA ROCK & GLASSIn order to use glass, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your glass and lay it on top of the lava rock and burner. The glass should only be 3/4” to 1”thick, or just enough to cover the burner.
LAVA ROCK
GLASS
LAVA ROCK & LAVA STONE
LAVA ROCK
LAVA STONEIn order to use lava stones, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your lava stones and lay it on top of the lava rock and burner. The lava stones should only be one layer thick, just enough to cover the burner.
LAVA ROCK & LAVA BOULDER
LAVA ROCK
LAVA BOULDERIn order to use lava boulders, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your lava boulders and lay it on top of the lava rock and burner. Lava boulders are 6” to 12” in diameter, there is enough room between them that gas can flow properly. You can use as many as you like.
LAVA ROCK & LOG SET
LAVA ROCK
LOG SETIn order to use a log set, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your log set and lay it on top of the lava rock and burner.
45
SQUARE FIRE PITS
LINEAR FIRE PITS
INSIDE DIAMETER LAVA ROCK ONLY LAVA ROCK AS A BASEGLASS ON TOP OF
LAVA ROCKLAVA STONE ON
TOP OF LAVA ROCKLAVA BOULDERS ON TOP
OF LAVA ROCK16” 10 lbs 5 lbs 10 lbs 10 lbs 1/4 box
19” 15 lbs 10 lbs 20 lbs 15 lbs 1/2 box
25” 20 lbs 15 lbs 30 lbs 20 lbs 3/4 box
29” 25 lbs 20 lbs 40 lbs 25 lbs 1 box
33” 30 lbs 25 lbs 50 lbs 30 lbs 1 box
34” 30 lbs 25 lbs 60 lbs 30 lbs 1 box
44” 50 lbs 35 lbs 70 lbs 50 lbs 2 - 3 boxes
ROUND FIRE PITS
HOW MUCH MEDIA TO USE
INSIDE DIAMETER LAVA ROCK ONLY LAVA ROCK AS A BASEGLASS ON TOP OF
LAVA ROCKLAVA STONE ON
TOP OF LAVA ROCKLAVA BOULDERS ON TOP
OF LAVA ROCK20” 15 lbs 10 lbs 20 lbs 15 lbs 1/2 box
26” 20 lbs 15 lbs 30 lbs 20 lbs 3/4 box
32” 30 lbs 25 lbs 50 lbs 30 lbs 1 box
38” 35 lbs 30 lbs 60 lbs 35 lbs 1 1/4 box
INSIDE DIAMETER LAVA ROCK ONLY GLASS ONLY LAVA STONE ONLY
24” 10 lbs 10 lbs 6 lbs
30” 10 lbs 13 lbs 10 lbs
36” 15 lbs 15 lbs 12 lbs
48” 16 lbs 20 lbs 16 lbs
54” 18 lbs 23 lbs 18 lbs
60” 20 lbs 26 lbs 20 lbs
66” 22 lbs 28 lbs 22 lbs
72” 24 lbs 30 lbs 24 lbs
46
CONTROLS
AF4000ADP24(80)110 volts AC adapter, coverts to 7.5 DC volts for TFS systems. Requires a weather resistant enclosure.
WIRING DIAGRAM
OUTPILOT ADJ
INMAIN
PILOT
Battery Pack
Black (Ground)
GreenWhite
2-Brown
White
Black (-)
Red (+)
Black (4-Pin Connector)
Red
Red
Blac
kBl
ack
Learn AUX
Rem
ote/
OFF
VCS-5000MODTCModule
IS
(Ignitor)(Sensor)(Thermocouple Ground Wire)
Ignitor Assembly
Copper
Orange
Tan
POWER
Orange
Latching Solenoid-DC Motor Drive
Low Rate Set Screw
The AF4000ADP24(80) plugs into the POWER plugs on the module, which is inside the metal box underneath the Fire Pit Burner System. Once the adaptor is plugged into the module, you must plug it in to a GFCI outlet that is installed in a double-outlet NEMA 3R Enclosure (not provided).
Please note that this adapter is only 24” long. Do not try to run this adaptor outside of the enclosure. An electrical line will need to be ran into the enclosure and secured using a double-outlet NEMA 3R Enclosure (not provided). Please review your local codes.
Please note that the battery pack still needs to be attached to the system for normal operation.
This is representative of the wires leaving the box in order to be plugged into the recepticle, which is outside the box but still inside the enclosure.
24”
1.1”
2.6”1.9”
Front View Side View
47
AF4000HAT
SPA
SPA WATERFALL
MUSIC
JETS
POOL
CLEANER
FOUNTAIN
GAS APPLIANCE
MENU HEAT LIGHTS DISPLAY
HOME AUTOMATION SYSTEMTFS FIRE PIT SYSTEM HAT TRANSMITTER
This is Firegear’s Home/Pool Automation Transmitter. It allows you to operate
your Firegear TFS product from the same controller you‘re used to using your
pool system. It’s important to note that even though you are using the HAT, you
can still use your original remote that came with your TFS unit.
This is a wireless signal. The transmitter must be within 20’ of the control module, which is located underneath the fire pit. If the AF-4000HAT is installed outside, it much be installed in a NEMA 3R Enclosure (not provided) or weather resistant enclosure.
The AF4000HAT comes with a wall plate making it easy to mount on any wall.
Maximum 100-feet of 18-gauge (or larger) wire that is suitable for outdoors
WIRING DIAGRAM
48
LIDS
5053-098
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.
2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-098.
ROUND LIDS
BURNER LIDS
SELECT DESIRED MODEL:
LID-16R
LID-19R
19" 5/8"
MODELOUTSIDE DIM.
ALID HEIGHT
B
TOP VIEW
LID-16RLID-19R
LID HEIGHT WITHHANDLE
22 3/8"2"
SIDE VIEW
A
B
LID-25R 28 3/8"LID-29R 32 1/2"LID-33R 36 1/2"
5/8" 2"5/8" 2"5/8" 2"5/8" 2"
LID-25R
LID-29R
LID-33R
MODELOUTSIDE DIM.
ALID HEIGHT
BLID HEIGHT
WITH HANDLE
LID-16R 19” 5/8” 2"
LID-19R 22 3/8” 5/8” 2”
LID-25R 28 3/8” 5/8” 2”
LID-29R 32 1/2” 5/8” 2”
LID-33R 36 1/2” 5/8” 2”
ROUND
SIDE VIEW
B
MODELOUTSIDE DIM.
ALID HEIGHT
BLID HEIGHT
WITH HANDLE
LID-20S 22 1/4” 1 1/4” 2"
LID-26S 28 1/4” 1 1/4” 2”
LID-32S 34 1/4” 1 1/4” 2”
LID-38S 40 1/4” 1 1/4” 2”
SQUARE
5053-099
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-099.
SQUARE LIDS
BURNER LIDS
SELECT DESIRED MODEL:
LID-20S
LID-26S
22 1/4" 1 1/4"
MODELOUTSIDE DIM.
ALID HEIGHT
B
TOP VIEW
LID-20SLID-26S
22 1/4"
LID WIDTHC
LID HEIGHT WITHHANDLE
28 1/4"2 5/8"
1 1/4"
SIDE VIEW
28 1/4" 2 5/8"
C
A
B
LID-32S 34 1/4" 1 1/4" 34 1/4" 2 5/8"LID-38S 40 1/4" 1 1/4" 40 1/4" 2 5/8"
LID-32S
LID-38S
5053-099
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.
3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-099.
SQUARE LIDS
BURNER LIDS
SELECT DESIRED MODEL:
LID-20S
LID-26S
22 1/4" 1 1/4"
MODELOUTSIDE DIM.
ALID HEIGHT
B
TOP VIEW
LID-20SLID-26S
22 1/4"
LID WIDTHC
LID HEIGHT WITHHANDLE
28 1/4"2 5/8"
1 1/4"
SIDE VIEW
28 1/4" 2 5/8"
C
A
B
LID-32S 34 1/4" 1 1/4" 34 1/4" 2 5/8"LID-38S 40 1/4" 1 1/4" 40 1/4" 2 5/8"
LID-32S
LID-38S
MODELLENGTH
ALID HEIGHT
BLID WIDTH
C FITS THESE MODELS
LID-24L 29 3/4” 2 5/8” 8 1/4” FPB-L24
LID-30L 35 3/4” 2 5/8” 8 1/4” FPB-L30
LID-36L 41 3/4” 2 5/8” 8 1/4” FPB-L36
LID-60L 53 3/4” 2 5/8” 8 1/4” (2)FPB-L24 End to End
LID-68L 69 3/4” 2 5/8” 8 1/4” (2)FPB-L30 End to End
LID-84L 77 3/4” 2 5/8” 8 1/4” (2)FPB-L36 End to End
LID-LOF30 32 3/8” 2 5/8” 8 1/4” LOF30 Series
LID-LOF36 38 3/8” 2 5/8” 8 1/4” LOF 36 Series
LINEAR
5053-097
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. LINEAR LIDS LISTED ABOVE WILL ONLY FIT LOF30 AND LOF36 MODELS AT THE CURRENT TIME.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-097.
LINEAR LIDS
BURNER LIDS
SELECT DESIRED MODEL:
LID-30L
LID-36L
32 3/8" 1 1/4"
MODELOUTSIDE DIM.
ALID HEIGHT
B
TOP VIEW
LID-30LLID-36L
8 1/4"
LID WIDTHC
LID HEIGHT WITHHANDLE
38 3/8"2 5/8"
1 1/4"
SIDE VIEW
8 1/4" 2 5/8"
C
B
A
5053-097
FIREGEAR OUTDOORS9230 CONSERVATION WAY
FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929
FAX: (888) 672-8024www.firegearoutdoors.com
CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.
REVISION DATE 05/26/2016
NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. LINEAR LIDS LISTED ABOVE WILL ONLY FIT LOF30 AND LOF36 MODELS AT THE CURRENT TIME.
3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES
ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-097.
LINEAR LIDS
BURNER LIDS
SELECT DESIRED MODEL:
LID-30L
LID-36L
32 3/8" 1 1/4"
MODELOUTSIDE DIM.
ALID HEIGHT
B
TOP VIEW
LID-30LLID-36L
8 1/4"
LID WIDTHC
LID HEIGHT WITHHANDLE
38 3/8"2 5/8"
1 1/4"
SIDE VIEW
8 1/4" 2 5/8"
C
B
A
SIDE VIEW
B
SIDE VIEW
B
49
WINDSHIELDS
MODEL DIAMETER FITS THESE PAN SIZES
GWS-22R 22” FPB16 - FPB19 (round)
ROUND
MODEL LENGTH WIDTH HEIGHT FITS THESE PAN SIZES
GWS-3030 30” 30” 7 1/2” FPB-20S (Square)
GWS-3838 38” 38” 7 1/2” FPB-26S, FPB-32S (Square)
GWS-4242 42” 42” 7 1/2” FPB-38S (Square)
GWS-3812 / GWS-3810 38”/38” 12”/10” 7 1/2” FPB-24L,LOF-30
GWS-4312 / GWS-4410 43”/44” 12”/10” 7 1/2” FPB-30L, FPB-36L, LOF-36
GWS-6010 60” 10” 7 1/2” FPB-24L + FPB-24L or FPB-30L + FPB-24L
GWS-8512 / GWS-8410 85”/84” 12”/10” 7 1/2” FPB-36L + FPB-36L or FPB-36L + FPB-30L
SQUARE / RECTANGULAR
50
VENT KIT
VENT-KIT-6X12
DESCRIPTION: These vents are designed to be used with Ready to Fit (RTF) enclosures as well as universal vent for many other types of fire pit enclosures. Figure 1 shows the actual dimensions of each vent.
Item # Part Number Description Qty.1 VENT- 6x12 6” x 12” Vent 22 SCREW1024PANBL 1.25” Phillips black pan head screw 123 ST3-113-1020 10x24 Stainless steel nut 124 WASHER10SS #10 Stainless steel flat washer 12
11.380”
5.750” 3.500”TYP.
.500” TYP.
12
3 4
Fig. 1 Vent dimensions.
Replacement Parts
Table 1: Part Identification
Vent Kit - 6x12 2-8-16 Page 1
These vents are designed to be used with Assemble-n-Finish (AnF) enclosures as well as a universal vent for many other types of fire pit enclosures.
9.750”
3.750”
Cut Out Detail
Install the vents on opposite sides of the enclosure to ensure cross flow ventilation. Cross flow ventilation is necessary to provide free flowing air to assist in keeping the enclosure dry and cool during operation of a fire pit.
Cut an rectangular opening 9.75” x 3.75” into on opposite sides of the enclosure. Center the vent over the cut out area ensuring the vent slots are clear of any obstruction. Mark the holes with a pencil or marker. Drill six ¼” clearance holes, place the vent centered over the opening, insert a screw into the vent and enclosure at the same time and secure with washer and nut on the inside. Repeat the process until all six screws are securing each vent into place on both sides of the enclosure.
Fig. 2 Cutting hole in enclosure and installing vent.
FOR TECHNICAL SERVICE, CALL:
Firegear Outdoors9230 Conservation WayFort Wayne, IN 46809
For Sales: (888) 672-8929
WEB SITE: www.firegearoutdoors.com
(855) 498-8324
Vent Kit - 6x12 2-8-16 Page 2
CROSS VENTILATIONFire pits are subjected to many outdoor elements such as rain, snow, wind, heat or cold. A minimum of 18 square inches of cross ventilation (2 sides) is required to keep the components in good working order. Use the figure below as a guide to assist you to incorperate proper ventilation.
When using LP gas, ventilation should be located near the base of the structure.
AIR FL
OW
The vents should be placed in the middle of the enclosure, and on opposite sides
AIR FLOW
51
Length of Pipe in Feet 1/2” 3/4” 1” 1 - 1/4” 1 - 1/2” 2” 2 - 2 1/2” 3” 4”
10 275 567 1071 2205 3307 6221 10140 17990 35710
20 189 393 732 1496 2299 4331 7046 12510 25520
30 152 315 590 1212 1858 3465 5695 10110 20620
40 129 267 504 1039 1559 2992 4778 8481 17300
50 114 237 448 913 1417 2646 4343 7708 15730
60 103 217 409 834 1275 2394 3908 6936 14150
70 89 185 346 724 1086 2047 3329 5908 12050
80 78 162 307 630 976 1811 2991 5309 10830
90 69 146 275 567 866 1606 2654 4711 9613
100 63 132 252 511 787 1496 2412 4281 8736
125 54 112 209 439 665 1282 2083 3618 7382
150 48 100 185 390 590 1138 1808 3210 6549
175 43 90 168 353 534 1030 1637 2905 5927
200 40 83 155 325 491 947 1505 2671 5450
300 37 77 144 303 458 887 1404 2492 5084
NATURAL GAS : PIPE SIZING CHART
• Natural Gas (NG) flow is given
in thousands of BTU/hr. One
cubic foot of LP gas - 1000 BTU
• Nominal pressure at the burner
for Natural Gas is 3.5” of water
column. (Typical machine
supply 5”-7”)
• Pipe length must include
additional length for all fittings.
Add approximately 5 feet of
pipe per fitting.
• Natural Gas Example: A
machine with a burner that
requires 440,000 BTU would
need a 1 -1/4” pipe for a 20”
long run.
LIQUID PROPANE : PIPE SIZING CHART
NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure. This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel Gas Code - current edition) for more details.
To determine how long a gas appliance will operate on one tank of gas first determined the total Btu’s of the propane tank. Divide that number by the total Btu’s of your appliance. This will provide to the approximate total time your gas appliance will operate on the tank of gas.
Example: I have a LP gas fire pit rated at 105,000 Btu’s and I am considering using a 20lb. Propane tank to operate it. If you take 430,000 Btu’s (total Btu’s of a 20lb. tank) divided by 105,000 Btu’s the total operating time will be approximate 4.09 hours.
PROPANE TANK BTU’S
Length of Pipe in Feet 1/2” 3/4” 1” 1 - 1/4” 1 - 1/2” 2” 2 - 2 1/2” 3” 4”
10 108 230 387 793 1237 2259 3640 6434 -
20 75 160 280 569 877 1610 2613 5236 9521
30 61 129 224 471 719 1335 2165 4107 7859
40 52 110 196 401 635 1143 1867 3258 6795
50 46 98 177 364 560 1041 1680 2936 6142
60 42 89 159 336 513 957 1559 2684 5647
70 38 82 149 317 476 896 1447 2492 5250
80 36 76 140 239 443 840 1353 2315 4900
90 33 71 133 275 420 793 1288 2203 4667
100 32 68 126 266 411 775 1246 2128 4518
125 28 60 117 243 369 700 1143 1904 4065
150 25 54 105 215 327 625 1008 1689 3645
175 23 50 93 196 303 583 993 1554 3370
200 22 47 84 182 280 541 877 1437 3160
300 17 37 70 145 224 439 686 1139 2539
• Liquid Propane (LP) Gas flow is
given in thousands of BTU/hr. -
One cubic foot of LP gas - 2516
BTU.
• This chart refers to low
pressure LP, after regulation,
Standard nominal pressure at
the burner for Liquid Propane
Gas is 11” of water column.
• Pipe length must include
additional length for all fittings.
Add approximately 5 feet of
pipe per fitting.
• LP Example: A machine with
a burner that requires 440,000
BTU would need a 1” pip for a
20’ long run.
11 lb. Tank 20 lb. Tank 30 lb. Tank 40 lb. Tank 50 lb. Tank
= 2.98 gal. of gas = 5 gal. of gas = 7 gal. of gas = 10 gal. of gas = 25 gal. of gas
= 256,205 Btu’s = 430,000 Btu’s = 640,000 Btu’s = 860,000 Btu’s = 2,159,400 Btu’s
52
Quote# Request Date
Distributor:
Phone (Office):
Street Address:
City:
Contact:
Email:
State:
Re-Seller:
Phone (Office):
Street Address:
City:
Contact:
Email:
State:
CONTACT INFO
Project Name:
Expected Need Date:
Zip:
Zip:
PROJECT INFORMATION : Please answer / select all that apply
Project Application: Commercial Residential Certification Required: YES NO
Gas Type: NG (Natural Gas) LP (Liquid Propane)
Please check which item best describes your project:
Complete custom fire feature (Includes Disc or Pan, Burner and Ignition System)
Custom Burner Only (No Pan, No Ignition System) Custom Pan Only
IGNITION TYPE : How to turn it on - Check one
Hot Surface, Electronic Ignition (Requires 120Vac) -
Battery Operated Electronic Ignition (TFS - Thermocouple Flame Sense)(Max 110,000 BTU)
TMS (Thermocouple Manual Safety)
Match Light with Manual Spark Ignition “Piezo” - Battery Operated
Match Light (Light with Butane Lighter)
Ignition Accessories for Electronic Systems - Check all that apply
Timer Emergency Shut Off Wall Switch Remote Control
Remote Control for Electronic Ignition Systems only (max distance is 25’ from appliance)
OPTIONAL: Manual Spark Ignition “Piezo” - Battery Operated
CUSTOM ORDER FORM
125,000 BTU 290,000 BTU 500,000 BTU
53
ROUND & SQUARE BURNERS : Select or fill in where applicable
Style of Pan
Flat Disc
Pan Style (Round)
Pan Style (Square)
Lip Required
Select One Below InsideOutside Dimension
YES NO
N/A
Size of Lip if different from 1 3/8” each side
LINEAR BURNERS : Fill out where applicable
Dimensions: Width
Linear Burner Flame Pattern : Select One
Length Depth
Field of Fire (H Style) Single Row of Fire
Please help us understand the enclosure that the Custom Burner will be installed in. If you have drawings or pictures, please provide those as attachments. The more details we have the smoother the quote process will be.
ENCLOSURE DETAILS : Select or fill in where applicable
Constructed of: CMU (Concrete Masonry Unit) RTF (Ready to Finish Enclosure)
Height
Paver / Brick
Height & Width of Enclosure:
Width
FINISHING MATERIALS : Select all that apply
Manufactured Stone Real Stone Paver / Brick Stucco Other
VENTILATION : Requires 18 square inches of cross ventilation
Size of vents being installed Do you want Firegear to provide vents? YES NO
ADDITIONAL INFORMATION OR REQUESTS
SAVE FORM BEFORE SENDING
EMAIL TO : [email protected] or FAX T0 : 888.672.8024
Depth
Lip Required YES NO Size of Lip if different from 1 3/8” each side
Burner Flame Expectations
Height of Flame
65,000 to 85,000 BTU 85,000 to 120,000 BTU 250,000 BTU 500,000 BTU
54
Mail or Email forms to:
Skytech Products GroupDisplay Claims Processing9230 Conservation Way, Fort Wayne IN 46809
Email: [email protected]
DEALER DISTRIBUTOR
ADDRESS
CITY STATE ZIP
CONTACT PHONE FAX
EMAIL WEBSITE
INSTALL DATE SUBMIT DATE
FIREGEAR ITEM #
SERIAL # IF APPLICABLE
INVOICE # COSTDISPLAY
ALLOWANCE %CREDIT
REQUESTED
TOTAL CREDIT REQUESTED
Submit claim form with a photograph of each eligible item and a copy of the original invoice. Photograph must show product burning. Product must remain on display for 12 months from date of submittal. Company reserves the right to charge back the display credit if the display is no longer available for consumer presentations. In order to qualify for Burn Display Allowance must be a functional gas burning display. Product purchased as part of the Firegear Outdoors Kiosk is excluded from the burn / display program.
Burn/Display credits will be issued exclusively toward future purchases of Firegear products.
AUTHORIZED DEALER SIGNATURE / DATEAUTHORIZED DISTRIBUTOR OR SKYTECH / FIREGEAR
FACTORY REPRESENTATIVE SIGNATURE / DATE
SKYTECH PG APPROVAL
CREDIT MEMO #
Burn / Display Credit Form 1-1-17
LIVE BURN PROGRAM
INSTALL LOCATIONADDRESS
CITY STATE ZIP
55
PHONE: 888.672.8929 FAX: 888.672.8024 EMAIL: [email protected]
CATEGORYCATALOG
PAGE #ELIGIBLE PRODUCTS
ADDITIONAL BURN CREDIT
Outdoor Fireplaces 8 - 9 Kalea Bay 36/48/60/72 50%
10 -11 OD42 20%
12 - 13 Key West See-Thru 40%
Fire Furnishings 16 - 17 Key West Bistro 20%
18 - 19 Key West Coffee Table 20%
Burner Systems 26 - 27 Round Burner Systems - UL Listed 40%
28 - 29 Flat Disc Burner Systems - UL Listed 40%
30 -31 Square Burner Systems - UL Listed 40%
32 - 33 L Series - UL Listed 40%
34 Round/Flat Disc/Square - Non Listed 40%
34 Line of Fire - Non Listed 20%
Assemble and Finish (AnF) 36 - 37 Round/Linear/Square AnF Enclosures 40%
Paver Kit Control Panels 38 - 39 Control Panels & Vent Kits 40%
Jewelry 46 Lava Rock/Lava Stone/Lava Boulder 50%
48 Glass 50%
50 - 51 Log Sets for Fire Pits 50%
Accessories 54 Controls 50%
55 Windshields 50%
56 Lids 50%
57 MSI Kits & Vent Kit 50%
68 Hoses & Regulators 50%
Dealer Tools 63 *Glass Tower 100%
Create a claim form with a photograph of each eligible item and a copy of the original invoice. Photograph must show product burning and must include model #, serial #, distributor/dealer name, physical address of display. Product must remain on display for 12 months from date of submittal. Company reserves the right to charge back the full amount of the display credit if the display is no longer available for consumer presentations. To qualify, Burn Display Allowance must be a functional gas burning display.
Kalea Bay Burn Display Requirements: To qualify for the Live Burn Display, Kalea Bay must have finishing material used to face the unit. If displaying as a See-Through, you may leave one side unfinished. No more than one live Kalea Bay display per location unless approved by Firegear Outdoors in writing. *Dealer can receive 100% credit with proof of purchase of $200 of Firegear Fireglass.
56
FG-LIT-CATALOG-17
DEALER
ORDER DATE
DISTRIBUTOR
ADDRESS
CITY STATE ZIP
CONTACT PHONE FAX
EMAIL ATTENTION
LITERATURE ORDER FORM
1
2017 CATALOG
THE BEST ROOM IN THE HOUSE
ISN’T IN THE HOUSE AT ALL
1
2017 SPECIFICATION BOOK
THE BEST ROOM IN THE HOUSE
ISN’T IN THE HOUSE AT ALL
2017 PRICE BOOK
THE BEST ROOM IN THE HOUSE
ISN’T IN THE HOUSE AT ALL
AnFAssemble and Finish
BUILDING A FIRE PITHAS NEVER BEEN THIS EASY
2017 CATALOG QUANTITY
FG-LIT-SPEC-172017 SPEC BOOK
FG-LIT-PRICING2017 PRICE BOOK
FG-LIT-ANFAnF LITERATURE
AVAILABLE ONLINE ONLY
QUANTITY
PACKSQUANTITY
only purchased in packs of 25
For special events and large quantities, please allow up to 2 weeks for processing and delivery. Expedited requests requiring express shipping are billable.
FAX or EMAIL forms to: 888.672.8024 or [email protected]
Also available online(See instructions below)
(See instructions below)
INSTRUCTIONS FOR ACCESSING LITERATURE ONLINE
Go to www.firegearoutdoors.comClick on the products tab
Scroll down until you see your desired literature pieceYou can then view, download or share the document!
57
NOTES
58
RETURN POLICY
Products that are defective or shipped in error may be returned.
ELIGIBLE PRODUCT
The customer should contact SPG to obtain a Return Material Authorization (RMA) number. The RMA number is required on all paperwork enclosed within the packaged and written on the shipping carton for easy identification upon receipt.
AUTHORIZATION
Each item being returned should be clearly tagged with the reason for the return. This will assist us in evaluating the product and provided a quicker return.
All products should be packaged to prevent damage in shipping. Product damaged during the return will be the responsibility of the customer. Return freight charges are the responsibility of the customer.
TAG & SHIP
It is our goal to evaluate, process and complete each return at our earliest convenience. However, every item returned to SPG is tested and evaluated, so the larger the return, the longer it may take to complete our evaluation. Therefore, we strongly recommend not holding returns for extended periods of time.
TIMING
All defective products must have an RMA issued by one of our technical support staff. To get an RMA please have your original purchase information available and contact the technical support staff. A technical support person will attempt to solve the problem over the telephone. If the technical support staff cannot troubleshoot the problem over the phone, an RMA number will be issued. The RMA number must be indicated on the outside of the returned package and a copy of the RMA worksheet should be within the package if applicable. The RMA is valid for 60 days after issued. Once we receive the product back testing will begin. It is important to note, the return should contain all contents originally shipped or testing will be delayed. If you have any questions on what should be returned, please contact the technical support staff.
DEFECTIVE PRODUCT
Attn. Technical Department9230 Conservation Way, Fort Wayne, IN 46809
P: 855.498.8324 F: 888.672.8024 E: [email protected]
59
Skytech Products Group (Firegear Outdoors) hereby warrants to the end user that products will be free from material and workmanship defects that prevent safe and correct operation of the product. The warranty commences from date of sale to the end user for the following period:
End User must provide a bill of sale, canceled check, or payment record from the end user to verify purchase date and to establish warranty period. This Limited Warranty shall be valid and limited to the original purchaser only.
WARNING Any modification to the product will void the warranty.
This Limited Warranty shall be limited to the repair and/or replacement of parts that have proven to be defective under normal use and service. Before returning any parts, contact our Technical Service Department for a Return Materials Authorization (RMA) number. All warranty claims must be made by the OEM / Distributor / Dealer account on behalf of the end user. You may contact Technical Service at (855) 498-8324.
All approved returned defects must be confirmed by our Technical Service Department. If the defect is confirmed and we approve the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
Travel, diagnostic cost, service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner. We will not be responsible for labor charges and/or damage incurred in installation, repair, and replacement.
LIMITED WARRANTY
This Limited Warranty is voided if not assembled, installed and operated as intended. This Limited Warranty does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, removal from the original location or re- installation into another location, or failure to perform normal and routine maintenance.
Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due to over-heating, exposure to chemicals (including salt), either directly or in the atmosphere, or very high humidity, is not covered by this Limited Warranty.
There are no other express warranties except as set forth herein. For consumer applications, any applicable implied warranties of merchantability and fitness are limited induration to the period of coverage of this Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you.
For Commercial applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular purpose or merchantability.
We are not liable for any special, indirect or consequential damages. Our maximum liability is limited to the purchase price of the purchased products. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusions may not apply to you.
We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such representations are binding.
Lava Rock and Lava Stones are not covered by warranty
CONSUMER/NON-COMMERCIAL APPLICATIONS:Stainless Steel Components 5 YearsGas Valve, Spark Igniter & Electronic Parts 2 YearsLog Sets 3 YearsGlass Windshields 5 YearsGlass Media 1 YearControls 5 YearsAnF Enclosures 5 Years
COMMERCIAL APPLICATIONS:Stainless Steel Components 1 YearGas Valve, Spark Igniter & Electronic Parts 1 YearLog Sets 1 YearGlass Windshields 1 YearGlass Media 1 YearControls 1 YearAnF Enclosures 1 Year
Lava Rock and Lava Stones are not covered by warranty
60
TECHNICAL SUPPORT:
9230 CONSERVATION WAY
FORT WAYNE, IN 46809
1.855.498.8324SALES SUPPORT: 1.888.672.8929
www.firegearoutdoors.com
FG-LIT-SPEC-17