Page 1: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

1

2017 SPECIFICATION BOOK

THE BEST ROOM IN THE HOUSE

ISN’T IN THE HOUSE AT ALL

VER: 04-11-17

Page 2: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

2

ITEM PAGE NUMBER

OUTDOOR FIREPLACES 4

FIRE FURNISHINGS 12

IGNITION SYSTEMS 14 - 17

ROUND BURNES 18

SQUARE BURNERS 22

FLAT DISC 26

L-SERIES 30

NON-LISTED BURNERS 34

AnF OUTDOOR LIVING ENCLOSURES 38

SPUR BURNERS 40

FLEXFRAME 41

PAVER KIT CONTROL PANELS 42

PAVER VENT KITS 43

MEDIA 44

CONTROLS 46

LIDS 48

WINDSHIELDS 49

VENT KIT 50

GAS LINE PIPE SIZING CHART / PROPANE TANK BTU’S

51

CUSTOM ORDER FORM 52

LIVE BURN PROGRAM 54

LITERATURE ORDER FORM 56

WARRANTY 59

HOW TO SIGN UP FOR

Go to www.firegearoutdoors.com and click on the CAD Details icon in the bottom right corner of the home page.

Once on the Firegear Outdoors CAD Detail website, click any product on the page.

Scroll down until you see REGISTER. Click the register button, input the information and finish the sign up process.

Once you are signed up, you then will have access to all of Firegear Outdoors design files.

Page 3: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

3

Skytech Products Group-Retail, including Skytech Systems and Firegear Outdoors (“SPG-Retail”), a Division of Skytech Products Group, has developed a Minimum Advertised Pricing (MAP) policy (the “Policy”) for all products sold by and purchased from SPG-Retail by and through traditional and/or online retailers (“Products”). In an effort to protect the image and value of SPG-Retail products and to maintain fair and equitable promotional and sales activity among its distributors, dealers, retailers and other resellers (each, a “Retailer”), SPG-Retail has developed the MAP Policy effective immediately. The MAP Policy and its terms and conditions are as follows:

Subject to certain exceptions set forth below, no Retailer shall, at any time, advertise or promote any SPG-Retail Products for sale or resale at a price lower than the MAP pricing established by SPG-Retail for such Products.

The MAP Policy shall apply to all promotions and/or advertisements of any Products purchased from SPG-Retail that appear in any media form, including, without limitation, written or electronic flyers, posters, coupons, mailers, inserts, newspapers, magazines, catalogs, mail order catalogs, Internet, online, or similar electronic media, websites, email newsletters, email solicitations, television, radio, and/or public signage. The MAP Policy shall not apply to (a) any in-store advertising displayed by a Retailer, in-store displays, point-of-sale signs, hang tags or bar codes, or similar product price packaging which merely state the price of such product; (b) the promotion or advertisement of discontinued Product, so long as such Product is clearly marked as discontinued within said advertisement or promotion; and (c) the actual price at which any Products are sold to an individual consumer at or from a Retailer’s physical location or via telephone.

MAP pricing is subject to change from time to time at the sole discretion of SPG-Retail and can be accessed by contacting SPG-Retail Divisions at (888) 672 8929, or by written request via email at [email protected] or [email protected]. It shall be the responsibility of all Retailers to remain current as to MAP Policy, pricing, and any changes thereto.The MAP Policy shall apply to all Products sold to SPG-Retail distributors and resold thereby to any Internet or online dealers and retailers, and such distributors shall take all necessary steps to enforce the MAP Policy in connection with each and every such resale.By accepting Products from SPG-Retail and in consideration of continued access to Products and the benefits realized as an SPG-Retail preferred, approved Retailer, each Retailer accepts and all Products they purchase from SPG-Retail shall be and remain subject to the MAP Policy as set forth herein. Should it be determined that any Product subject to the MAP Policy is or has been advertised or promoted at a price below the MAP pricing established for said Product by SPG-Retail at any time, the violating Retailer shall immediately take all steps necessary to cure said violation and bring its advertising, promotion, pricing and sales activity into compliance with the MAP Policy. SPG-Retail hereby, at any time, reserves the right to discontinue the shipment of Products to the violating Retailer and/or its distributor, and the right to terminate future sales of Products to said violating Retailer and/or its distributor, subject to the parties’ respective financial and confidential obligations that shall survive such termination.

POLICY

APPLICATION

OTHER TERMS & CONDITIONS

MAP POLICY MINIMUM ADVERTISED POLICY

Page 4: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

4

KALEA BAY SPECIFICATIONS

MODEL

OVERALL LENGTH

A

INSIDE OPENING

B

OVERALL HEIGHT

C

OPENINGHEIGHT

D

OVERALL DEPTH

E

LEG HEIGHT

F

VALVE BOX

DEPTHG

CLEARANCE TO COMBUSTABLE

SIDE WALLH

CLEARANCE TO COMBUSTABLE

CEILINGI

OFP-36LTFS-N or P 40” 36" 37 1/2" 16” 16” 11 1/2" 8 3/4” 6” 42 1/2”

OFP-48LTFS-N or P 52” 48" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”

OFP-60LTFS-N or P 64” 60" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”

OFP-72LTFS-N or P 76” 72" 37 1/2” 16” 16” 11 1/2” 8 3/4” 6” 42 1/2”

FRONT VIEW

TOP VIEW

END VIEW

E

E

C

6”

20”

F

D

A

B

GBottom Finish Fin

Hood

I

H

END VIEW

SIDEWALL

CEILING

FLOOR

11½”

FRONT VIEW

TOP VIEW

END VIEW

E

E

C

6”

20”

F

D

A

B

GBottom Finish Fin

Hood

SINGLE SIDED FIREPLACE DIMENSIONS & CLEARANCES

OPTIONAL ACCESSORIES326-930 Driftwood 6 piece twig set

TM-R-AF1TX Wireless wall mount timer (30/60/120min)

1322WT Wireless wall mount switch (On/Off/High/Low)

1001D-AF1TX Wireless wall mount switch (On/Off)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)

WS Wired wall mount switch (On/Off)

OFP-48LTFS-N 48” w x 16” h x 16” d opening dimensions. Natural Gas (43,500 Btu on High, 24,500 Btu on Low)

OFP-60LTFS-N 60” w x 16” h x 16” d opening dimensions. Natural Gas (50,000 Btu on High, 36,000 Btu on Low)

OFP-72LTFS-N 72” w x 16” h x 16” d opening dimensions. Natural Gas (65,000 Btu on High, 42,000 Btu on Low)

OFP-36LTFS-N 36” w x 16” h x 16” d opening dimensions. Natural Gas (31,000 Btu on High, 18,500 Btu on Low)

OFP-36LTFS-P 36” w x 16” h x 16” d opening dimensions. Liquid Propane (30,000 Btu on High, 19,500 Btu on Low)

OFP-48LTFS-P 48” w x 16” h x 16” d opening dimensions. Liquid Propane (42,500 Btu on High, 29,000 Btu on Low)

OFP-60LTFS-P 60” w x 16” h x 16” d opening dimensions. Liquid Propane (50,000 Btu on High, 36,000 Btu on Low)

OFP-72LTFS-P 72” w x 16” h x 16” d opening dimensions. Liquid Propane (60,000 Btu on High, 45,000 Btu on Low)

MODELS

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

FIREPLACES

Page 5: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

5

MODEL

OVERALL LENGTH

A

INSIDE OPENING

B

OVERALL HEIGHT

C

OPENINGHEIGHT

D

OVERALL DEPTH

E

LEG HEIGHT

F

VALVE BOX

DEPTHG

CLEARANCE TO COMBUSTABLE

SIDE WALLH

CLEARANCE TO COMBUSTABLE

CEILINGI

OFP-36LTFS-N or P 40” 36" 37 1/2" 16” 16” 11 1/2" 8 3/4” 36” 42 1/2”

OFP-48LTFS-N or P 52” 48" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”

OFP-60LTFS-N or P 64” 60" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”

OFP-72LTFS-N or P 76” 72" 37 1/2” 16” 16” 11 1/2” 8 3/4” 36” 42 1/2”

FRONT VIEW

TOP VIEW

END VIEW

E

E

C

6”

20”

F

D

A

B

GBottom Finish Fin

Hood

FRONT VIEW

TOP VIEW

END VIEW

E

E

C

6”

20”

F

D

A

B

GBottom Finish Fin

Hood

SEE-THROUGH FIREPLACE DIMENSIONS & CLEARANCES

I

H

END VIEW

SIDEWALL

CEILING

FLOOR

11½”

Page 6: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

6

MODELWIDTH

AHEIGHT

BDEPTH

C

OFP-L36TFS-N or P 40 1/2” 37 3/4" 16”

OFP-L48TFS-N or P 52 1/2” 37 3/4” 16”

OFP-L60TFS-N or P 64 1/2” 37 3/4” 16”

OFP-L72TFS-N or P 76 1/2” 37 3/4” 16”

METAL STUDS

A

B

C

Metal Studs Metal Studs

Met

al S

tudsMet

al S

tuds

*Metal studs shown in gray.

Bottom Support Fin

Hood

MODELWIDTH

AHEIGHT

BDEPTH

C

OFP-L36TFS-N or P 52” 49 1/2" 28”

OFP-L48TFS-N or P 64” 49 1/2” 28”

OFP-L60TFS-N or P 76” 49 1/2” 28”

OFP-L72TFS-N or P 88” 49 1/2” 28”

WOOD STUDS

A

B

CWood Studs Wood Studs

Woo

d St

uds

Woo

d St

uds

*Wood studs shown in gray.

Bottom Support Fin

Hood

Stando�sStando�s

Wood Studs

NOTE: The Kalea Bay fireplace is not a “load bearing” fireplace. All finishing materials must be supported by the surrounding structure and not rely on the fireplace itself.

FOR BOTH SINGLE SIDED & SEE-THROUGHKALEA BAY FRAMING DIMENSIONS

Page 7: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

7

CONVERTING KALEA BAY INTO A SEE-THROUGH FIREPLACE

BACK VIEW REAR PANEL INSTALLED

BACK VIEW REAR PANEL REMOVED

Bottom Finish Fin

Side View Detail for Removal Rear Panel Screws

If you have determined to install the fireplace as a see-through model then you will need to remove the rear back panel to convert it. Before removing the back panel be sure to remove the contents out of the firebox area.

Use the following steps:

Step 1: Look at the back side of the fireplace. Around the outer perimeter area of the frame or back wall are several screws to remove.

Note: The numbers of screws to remove will vary with each fireplace model.

Step 2: The back panel will not be used again in the see-through application. Keep the back panel and screws if you need to switch the unit back to a single sided unit.

Watch for sharp edges

NOTE: When converting to the see-through fireplace the windshield clips will need to be installed. Two windshield clips are already installed for a single-sided fireplace, the other two clips will need to be installed for a see-through model. The clips will be packaged with the glass windshields. The retaining screws for the clips are already installed in the fireplace. Simply remove the screws and re-attach with the windshield clips in place.

The see-through fireplace requires both windshields to be intalled for proper operation.

The bottom support fin has pre-punched holes on the inside edge to secure fin into place before attaching cement board and the additional hood will need to be installed.

Page 8: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

8

HIGH ELEVATION: This unit is approved from altitude 0 to 4500 ft (CAN12.17-M91)

MODELSOD42-N Outdoor Linear Fireplace includes 2’’ Brushed Stainless

Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Natural Gas

OD42-P Outdoor Linear Fireplace includes 2’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Propane

OD42-4-N Outdoor Linear Fireplace includes 4’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Natural Gas

OD42-4-P Outdoor Linear Fireplace includes 4’’ Brushed Stainless Steel Faceplate, Copper Reflective Glass, Weather Cover, Wall Switch - Propane

OPTIONAL ACCESSORIES326-900 Steel stud framing kit. Overall dimensions 60”

wide x 20” deep x 52 1/2” high

326-930 Driftwood 6 piece twig set

1001-A Wireless hand held remote (On/Off)

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

OD42 SPECIFICATIONS

OD42-N or P DIMENSIONS

NOTES

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-001.

OD42 OUTDOOR FIREPLACE

OD42

5053-001

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/15/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

OD42-N

LP GAS:

#29 44,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#47 43,500MIN. INLET 5.0" WC 11.0" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

14.0" WC3.5" WC

14.0" WC10.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

OD42-P

OD42-NOD42-P

I NT ER EK

L I ST ED

US

CM

FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 2" STAINLESS STEEL

TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.

22 5/8"

35 1/4"

39 1/2"

12 3/4"17"

15 9/16"

11 1/2"10"

32 7/16"

23 5/16"

6 3/4"

6 5/16"

5/8"

FRONT VIEW SIDE VIEW

HEAT SHIELD

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-001.

OD42 OUTDOOR FIREPLACE

OD42

5053-001

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/15/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

OD42-N

LP GAS:

#29 44,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#47 43,500MIN. INLET 5.0" WC 11.0" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

14.0" WC3.5" WC

14.0" WC10.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

OD42-P

OD42-NOD42-P

I NT ER EK

L I ST ED

US

CM

FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 2" STAINLESS STEEL

TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.

22 5/8"

35 1/4"

39 1/2"

12 3/4"17"

15 9/16"

11 1/2"10"

32 7/16"

23 5/16"

6 3/4"

6 5/16"

5/8"

FRONT VIEW SIDE VIEW

HEAT SHIELD

OD42-4-N or P DIMENSIONS

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-002.

OD42-4 OUTDOOR FIREPLACE

OD42

5053-002

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/20/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

OD42-4-N

LP GAS:

#29 44,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#47 43,500MIN. INLET 5.0" WC 11.0" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

14.0" WC3.5" WC

14.0" WC10.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

OD42-4-P

OD42-4-NOD42-4-P

FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 4" STAINLESS STEEL

TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.

FRONT VIEW SIDE VIEW

15 9/16"

11 1/2"10"5/8"

32 7/16"

25 5/16"

6 3/4"

4 5/16"

22 5/8"35 1/4"

43 1/4"

12 3/4"20 3/4"

I NT EREK

L I ST ED

US

CM

HEAT SHIELD

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-002.

OD42-4 OUTDOOR FIREPLACE

OD42

5053-002

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/20/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

OD42-4-N

LP GAS:

#29 44,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#47 43,500MIN. INLET 5.0" WC 11.0" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

14.0" WC3.5" WC

14.0" WC10.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

OD42-4-P

OD42-4-NOD42-4-P

FEATURES: OD42 FIREPLACE HAS A STAINLESS STEEL FIREBOX WITH REFLECTIVE PANELS, 30" STAINLESS STEEL BURNER, COPPER REFLECTIVEFIREGLASS, BATTERY OPERATED ELECTRONIC IGNITION, TEMPERED GLASS WINDSHIELD WITH BLACK POLYESTER COVER, 4" STAINLESS STEEL

TRIM AND ON/OFF WALL SWITCH. ROUGH FRAMING DIMENSIONS ARE 43 1/16" WIDE X 32 11/16" TALL X 20" DEEP (STEEL STUDS MUST BE USED). SEEOD42 INSTALL MANUAL FOR MORE DETAILS.

FRONT VIEW SIDE VIEW

15 9/16"

11 1/2"10"5/8"

32 7/16"

25 5/16"

6 3/4"

4 5/16"

22 5/8"35 1/4"

43 1/4"

12 3/4"20 3/4"

I NT EREK

L I ST ED

US

CM

HEAT SHIELD

MODEL BTUSPECIFICATIONS

FACTORYORIFICE

BTUOUTPUT

OD42-N #29 44,500

OD42-P #47 43,500

OD42-N or P SYSTEM INFO

PRESSUREGAS

TYPE NGGAS

TYPE LP

MIX INLET 5.0”WC 11.0”WC

MAX INLET 14.0”WC 14.0”WC

MANIFOLD 3.5”WC 10.0”WC

MODEL BTUSPECIFICATIONS

FACTORYORIFICE

BTUOUTPUT

OD42-4-N #29 44,500

OD42-4-P #47 43,500

OD42-4-N or P SYSTEM INFO

PRESSUREGAS

TYPE NGGAS

TYPE LP

MIX INLET 5.0”WC 11.0”WC

MAX INLET 14.0”WC 14.0”WC

MANIFOLD 3.5”WC 10.0”WC

Tested to CAN/CGA-2.17-M91 / IAS 4-96 (US) / CGA CR97-003 (CAN) 4001172

Page 9: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

9

The clearances listed below are Minimum distances unless otherwise stated.

A major cause of fire is failure to maintain required clearances (air space) to combustable materials. It is of the greatest importance that the fireplace be installed only in accordance with these instructions.

A

B

F

E

D

AC

BF

Clearance Dimension Measured From

A: Sidewall 11’’ (203mm) Side of fireplace opening

B: Ceiling 36’’ (914mm) Top of fireplace opening

C: Mantel Height (min) 26 1/2’’ (673mm) Top of fireplace opening

D: Mantel Depth (max) 12’’ (304mm) From wall

E: Alcove Width 57’’ (1148mm) Wall to wall (min)

F: Alcove Depth 36’’ (914mm) Front to back wall (max)

Notes: 0’’ No hearth requiredThis table corresponds with the images below

F

E

When selecting a location for your fireplace, ensure that the proper clearances are met. Please refer to the product install manual for the measurement points to maintain proper distances.

MINIMUM CLEARANCES TO COMBUSTIBLES

OD42 FRAMING KITMODEL #: 326-900

NOTES:2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.2. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AND WELL AS ALL GAS CONNECTIONS.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE DRAWING ABOVE.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-003.

OD42 326-900 - FRAMING KIT

OD42

5053-003

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/15/2016

SELECT DESIRED SYSTEM:

OD42 FRAMING KIT

326-900

OD42 FRAMING KIT CONTAINS: (2) TOP/BOTTOM SUPPORTS, (8) TALL VERTICAL SUPPORTS, (6) SHORT VERTICAL SUPPORTS, (1) BASE, (1) HEADER, (2) CORNER BRACES, (1) CENTER VERTICAL SUPPORT, (1) VENT-KIT-6X12 AND (80) WAFER SCREWS.

TOOLS REQUIRED FOR ASSEMBLY: POWER DRILL, #2 HAND SCREWDRIVER, LEVEL AND TAPE MEASURE. NON-COMBUSTIBLE CEMENT BOARD IS NOT SUPPLIED. SEE 326-900 FRAMING KIT INSTALL MANUAL FOR MORE DETAILS.

ISOMETRIC

60"

20"

11"

18 1/2"

18"

52 1/2"

HEAT SHIELD

Page 10: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

10

KEY WEST SEE-THROUGH SPECIFICATIONS

MODELSKWST-42-N (1) FPB-30LTFS-N or P, Steel Stud Framing Kit

(KD - Knock Down) Ready to assemble, pre-drilled and labeled. Stainless Steel Reflective Side Walls and Ceiling Panel, Fireglass (10lb.), GWS-3810 Glass Windshield, On/Off/High/Low Remote Control (RCAF-3), VENT-KIT-6x12

OPTIONAL ACCESSORIES

KWST-42-P

KWST-82-N (2) FPB-30LTFS-N or P, Ready to Finish Enclosure (Assembled), Fireglass (20lb.), GWS-6810 Glass Windshield, On/Off/High/Low Remote Control (RCAF-3), VENT-KIT-6x12

KWST-82-P

326-930 Driftwood 6 piece twig set

TM-R-AF1TX Wireless wall mount timer (30/60/120min)

1322WT Wireless wall mount switch (On/Off/High/Low)

1001D-AF1TX Wireless wall mount switch (On/Off)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)

LID-68L Linear stainless steel lid with brushed finish for the KWST-82

377-909 Key West See Through kit propane drawer kit (KWST-42-N only)

LID-30L Linear stainless steel lid with brushed finish for the KWST-42

WS Wired wall mount switch (On/Off)

NOTES

KWST-42 SPECIFICATIONS

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.

5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-008.

KWST42 SYSTEM

KEY WEST SEE THRU

5053-008

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/20/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

KW42ST-N

LP GAS:

#35 42,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

HI

#47 42,000MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

10.5" WC7.0" WC

13.0" WC11.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

FPB-30LTFS-N

FEATURES: KWST42 SYSTEM COMES WITH EITHER (1) FPB-30LTFS-N OR (1) FPB-30LTFS-P BURNERS, READY TO ASSEMBLE FRAMING KIT, 20 LBS OFFIREGLASS, GWS-3812 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROL AND (1) VENT-KIT-6X12.

SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.

CUT OUT DIMENSIONS FOR BURNERS

FPB-30LTFS-P23,000

BTU OUTPUTLOW

30,000

KW42ST-P

PERSPECTIVE

FRAMING PERSPECTIVE

51"

11"64 1/16"

19"

8 1/2"

20 1/2"

42"

2"

4 7/8"

37"

9 1/4"

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.

5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-008.

KWST42 SYSTEM

KEY WEST SEE THRU

5053-008

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/20/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

KW42ST-N

LP GAS:

#35 42,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

HI

#47 42,000MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

10.5" WC7.0" WC

13.0" WC11.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

FPB-30LTFS-N

FEATURES: KWST42 SYSTEM COMES WITH EITHER (1) FPB-30LTFS-N OR (1) FPB-30LTFS-P BURNERS, READY TO ASSEMBLE FRAMING KIT, 20 LBS OFFIREGLASS, GWS-3812 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROL AND (1) VENT-KIT-6X12.

SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.

CUT OUT DIMENSIONS FOR BURNERS

FPB-30LTFS-P23,000

BTU OUTPUTLOW

30,000

KW42ST-P

PERSPECTIVE

FRAMING PERSPECTIVE

51"

11"64 1/16"

19"

8 1/2"

20 1/2"

42"

2"

4 7/8"

37"

9 1/4"

MODEL BTUSPECIFICATIONS

FACTORYORIFICE

BTU OUTPUTHIGH

BTU OUTPUTLOW

FPB-30LTFS-N #35 42,000 23,000

FPB-30LTFS-P #47 42,000 30,000

PRESSURE GAS TYPE NG GAS TYPE LP

MIN INLET 5.0” WC 10.5” WC

MAX INLET 10.5” WC 13.0” WC

MANIFOLD 7.0” WC 11.0” WC

KWST-42-N or P uses one (1) FPB-30LTFS-N or P

KWST-82-N or P uses two (2) FPB-30LTFS-N or P

The area below the burner must remain empy to allow proper air ventilation

Non-Combistible board withvent installed

Page 11: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

11

MINIMUM CLEARANCES TO COMBUSTABLES

KWST-82 SPECIFICATIONS

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.

6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-005.

KWST82 SYSTEM

KEY WEST SEE THRU

5053-005

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/15/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

KWST-82-N

LP GAS:

#35 84,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

HI

#47 84,000MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

10.5" WC7.0" WC

13.0" WC11.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

FPB-30LTFS-N (2)

FEATURES: KWST82 SYSTEM COMES WITH EITHER (2) FPB-30LTFS-N OR (2) FPB-30LTFS-P BURNERS, READY TO FINISH ASSEMBLED ENCLOSURE,20 LBS OF FIREGLASS, 377-955 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, TWO RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROLS AND (1)

VENT-KIT-6X12. SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.

KWST-82-P

FPB-30LTFS-P (2)46,000

BTU OUTPUTLOW

60,000

81 1/2"

24"6 3/4"

54 1/2"

11" 79 1/4"27 3/4"

19 1/2"

102"

7 1/2"

8 3/8"

67"6"

NOTES:1. THESE FIREPLACE MODELS ARE SHIPPED AS NATURAL GAS OR LP GAS AND MUST BE ORDERED ACCORDINGLY. THERE IS NO CONVERSION KIT.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALL FIREPLACE INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. KWST82 MODELS MUST SHIP LTL ONLY. SKID SIZE IS 104" LONG X 48" WIDE X 59 1/2" TALL. ESTIMATED SHIPPING WEIGHT IS 720 LBS.

6. 6X12 VENTS MUST BE INSTALLED APPROXIMATELY MID-WAY INTO THE ENCLOSURE FOR AMPLE VENTILATION. SEE PERSPECTIVE DRAWING.7. DRAWINGS NOT TO SCALE.8. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.9. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-005.

KWST82 SYSTEM

KEY WEST SEE THRU

5053-005

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/15/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

KWST-82-N

LP GAS:

#35 84,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

HI

#47 84,000MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETMANIFOLD

10.5" WC7.0" WC

13.0" WC11.0" WC

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE.FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROM THE LISTED BTU

SPECIFICATIONS.

FPB-30LTFS-N (2)

FEATURES: KWST82 SYSTEM COMES WITH EITHER (2) FPB-30LTFS-N OR (2) FPB-30LTFS-P BURNERS, READY TO FINISH ASSEMBLED ENCLOSURE,20 LBS OF FIREGLASS, 377-955 GLASS WINDSHIELD WITH BLACK POLYESTER COVER, TWO RCAF-3 (ON/OFF/HI/LO) REMOTE CONTROLS AND (1)

VENT-KIT-6X12. SEE LINEAR TFS FIRE PITS FOR BURNER DETAILS.

KWST-82-P

FPB-30LTFS-P (2)46,000

BTU OUTPUTLOW

60,000

81 1/2"

24"6 3/4"

54 1/2"

11" 79 1/4"27 3/4"

19 1/2"

102"

7 1/2"

8 3/8"

67"6"

MODEL BTUSPECIFICATIONS

FACTORYORIFICE

BTU OUTPUTHIGH

BTU OUTPUTLOW

(2) FPB-30LTFS-N #35 84,000 46,000

(2) FPB-30LTFS-P #47 84,000 60,000

PRESSURE GAS TYPE NG GAS TYPE LP

MIN INLET 5.0” WC 10.5” WC

MAX INLET 10.5” WC 13.0” WC

MANIFOLD 7.0” WC 11.0” WC

Finished side withvent installed

The area below the burner must remain empy to allow proper air ventilation

Model Ceiling Side Wall Floor

KWST-42-N or P 45 17 22

KWST-82-N or P 45 17 27 3/4

A

B

C

Page 12: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

12

KEY WEST BISTRO SPECIFICATIONS

MODELS

KWBTO-L-SS Key West Bistro Table with Iron Grey Base and Stainless Steel Top, 286-927 Stainless Steel Top, 34,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).

OPTIONAL ACCESSORIES

326-930 Driftwood 6 piece twig set

286-932 Tempered Glass Windshield (14 1/2” Long x 14 1/2” Wide x 6” Tall) Black Polyester Cover included

286-938 Protective Weather Cover

KWBTO-L-IG Key West Bistro Table with Iron Grey Base and Top, KWBTO-L, 286-924 Iron Grey Top, 34,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).

286-968 Key West Bistro Table Natural Gas conversion kit

Shown with optional Glass Windshield (286-932)

DIMENSIONS

CLEARANCE TO COMBUSTIBLES

AA

B

C

D

E

F

CLEARANCE DIMENSION MEASURED FROM

A: Back Wall 17” (432mm) Burner to back wall

B: Side Wall 17” (432mm) Burner to side wall

C: Ceiling 45” (1143mm) Burner to ceiling

D1: Floor 0” When using supplied leveling legs

D2: Floor 1” (25mm) Unit base to floor

E: Alcove Width 84” (2134mm) Wall to wall MIN

F: Alcove Depth 60” (1524mm) Front to back wall MAX AA

B

C

D

E

F

Tested and listed by Intertek for installation in USA and Canada

Page 13: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

13

KEY WEST COFFEE TABLE SPECIFICATIONS

MODELS

KWCH-P-BR Key West Coffee Table with Sunset Bronze Top, KWCH-L1, 377-926 Table Top, 49,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).

OPTIONAL ACCESSORIES

326-930 Driftwood 6 piece twig set

GWS-3812 Tempered Glass Windshield (38” Long x 12 7/8” Wide x 7 1/2” Tall)

376-029 Black Polyester Cover for GWS-3812

KWCH-P-SS Key West Coffee Table with Stainless Steel Top, KWCH-L1, 377-927 Table Top, 49,000 Btu Liquid Propane. Requires 10 lbs. of Fireglass (sold separately).

376-968 Natural Gas conversion kit for Key West Coffee Table (KWCH-P-SS & KWCH-P-BR), 50,000 BTU

377-938 Protective Weather Cover for Key West Coffee Table

DIMENSIONS

CLEARANCE TO COMBUSTIBLES

AA

B

C

D

E

F

CLEARANCE DIMENSION MEASURED FROM

A: Back Wall 17” (432mm) Burner to back wall

B: Side Wall 17” (432mm) Burner to side wall

C: Ceiling 45” (1143mm) Burner to ceiling

D1: Floor 0” When using supplied leveling legs

D2: Floor 1” (25mm) Unit base to floor

E: Alcove Width 84” (2134mm) Wall to wall MIN

F: Alcove Depth 60” (1524mm) Front to back wall MAX AA

B

C

D

E

F

Tested and listed by Intertek for installation in USA and Canada

Page 14: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

14

IGNITION SYSTEMS

MATCH THROW (MT)

KEY VALVEINCOMING GAS LINE

GAS FLEX LINE TO BURNER

HOW TO LIGHT1. Insert key into shut-off valve and secure key onto square end of the valve.

2. Light a long match or Butane lighter and hold it near the burner.

3. Turn the key counter-clockwise on gas valve (until it stops) to allow gas to flow and simultaneously apply the long burning

match or Butane lighter as close to the end of the burner as possible.

4. Gas should ignite within 10 seconds or less. If fire pit does not light within 10 seconds turn key clockwise to turn OFF the gas

supply. Ensure there is not too much media on top of the burner that might inhibit gas flow and try again in 5-minutes. Please

refer to page 42 for the recommended amount of media to install for your pan size.

7/8” Washer

Brass Nut

OASNG#(Burner Ori�ce)

U3-8D-S (Fitting)

Spur Burner

KC-PC(Decorative Flange)

BVS (Manual Key Valve)

U1-8D-S

U1-8D-S (Fitting)

Fire Pit Pan

Inlet Gas Supply

Expanded View of Match Throw (MT) Fire Pits

T200-9898-46 (Flex Connector)

Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.

(Not Supplied)

REV. 2-16-17MT Expanded View

EXPANDED VIEW

Page 15: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

15

THERMOCOUPLEVALVE

INCOMING GAS LINE

GAS FLEX LINE TO BURNER THERMOCOUPLECONNECTION

1. Light a long match or Butane lighter and hold it near the burner.

2. Rotate the control knob of the gas valve counter-clockwise to the ON position.

3. Depress control knob inward and push to light the burner at the same time.

4. After the fire pit lights continue to depress the control knob for 30 seconds then release knob. If the fire pit does not light within 30 seconds,

release knob, turn knob clockwise to turn OFF and wait 5 minutes before trying again.

HOW TO LIGHT

REV. 2-16-17TMS Expanded View

7/8” Washer

Brass Nut

OASNG#(Burner Ori�ce)

U3-8D-S (Fitting)

Expanded View of Thermocouple Manual (TMS) Safety Fire Pit

T200-9898-46 (Flex Connector)

Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.

Manual Gas Valve(ST3-080-1009) Mounting Nut

Thermocouple

Inlet Gas Supply

Male Threads: Requires Compound or Tape

(No compound/tape on �ared �ttings)

48-86 (Fitting not supplied: ½” Flare

to 3/8” Male Thread Fitting)

U1-8C-S (Fitting)

Spur Burner

Fire Pit Pan

Knob

EXPANDED VIEW

THERMOCOUPLE MANUAL SAFETY (TMS)

Page 16: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

16

IGNITION SYSTEMS

1. Press the ON button on the hand-held remote transmitter. You will hear the igniter

probe begin sparking for 15 seconds and the fire pit will ignite.

2. If the fire pit does not light the module will start to “beep” one time every second

indicating an ignition error. If this occurs press the OFF button on the transmitter

and repeat step 1.

3. If fire pit does not light after second try, turn main gas OFF, wait 5 minutes and

repeat steps 1-3.

HOW TO LIGHT

REV. 2-16-17TFS Expanded View

Valve Box: (Gas valve,control module

and wires inside)

Battery Pack

Expanded View of Thermocouple Flame Sense (TFS) Fire Pits

Thermocouple & Ground Wires

Black Wire

Flat Disc Pan

Spur Burner Ignition Hood

7⁄8” WasherBrass Nut

OAS-NG#(Burner Ori�ce)

½” Coupler

T-200-9898-46 (Flex Conector)

Note: Use joint compound or Te�on tape resistant to all gasses on all male NPT threads; not �ared �ttings. Ensure all connections are tight and check for gas leaks before and after assembly is complete.

Orange Ignition Wire

(3) 7⁄8” Washers

Inlet Gas Supply

EXPANDED VIEW

THERMOCOUPLE FLAME SENSE (TFS)

Page 17: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

17

INCOMING GAS LINEBATTERY PACK

VALVEBOX

IGNITOR CONNECTION

GAS FLEX LINE

TFS Wiring Diagram

4-21-16

OUTPILOT ADJ

INMAIN

PILOT

Battery Pack

Black (Ground)

GreenWhite

2-Brown

White

Black (-)

Red (+)

Black (4-Pin Connector)

Red

Red

Blac

kBl

ack

Learn AUX

Rem

ote/

OFF

VCS-5000MODTCModule

IS

(Ignitor)(Sensor)(Thermocouple Ground Wire)

Ignitor Assembly

TFS Wiring Diagram

Copper

Orange

Tan

POWER

Orange

Latching Solenoid-DC Motor Drive

Low Rate Set Screw

ROUND | SQUARE | DISC

LINEAR | L-SERIES

WHATS IN THE BOX?

OUTPILOT ADJ

INMAIN

PILOT

Battery Pack

Black (Ground)

GreenWhite

2-Brown

White

Black (-)

Red (+)

Black (4-Pin Connector)

Red

Red

Blac

kBl

ack

Learn AUX

Rem

ote/

OFF

VCS-5000MODTCModule

IS

(Ignitor)(Sensor)(Thermocouple Ground Wire)

Pilot AssemblyTFS Linear Wiring Diagram

Copper

Orange

Tan

POWER

Orange

Latching Solenoid-DC Motor Drive

Low Rate Set Screw

WHATS IN THE BOX?

VALVEBOX

PILOTCONNECTION

BATTERY PACK

INCOMINGGAS LINE

GAS FLEX LINE

NOTE: The battery box should not be located inside the stainless steel enclosure. The battery box must be installed in a NEMA 3R Enclosure. It needs to be readily accessible to the end user in order to perform maintenance.

NOTE: The battery box should not be located inside the stainless steel enclosure. The battery box must be installed in a NEMA 3R Enclosure. It needs to be readily accessible to the end user in order to perform maintenance.

Page 18: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

18

ROUND BURNER SYSTEMS SPECIFICATIONS

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-19RBSTFS-N 22” 19 1/4" - 21 1/2" 19" 2 3/4" 12 3/4" 18" 16" 54"

FPB-19RBSTFS-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 12 3/4" 18" 16" 54"

FPB-25RBSTFS-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 12 3/4" 18" 19" 69"

FPB-25RBSTFS-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 12 3/4" 18" 19" 69"

FPB-29RBSTFS-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 12 3/4" 18" 19" 69"

FPB-29RBSTFS-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 12 3/4" 18" 19" 69"

FPB-33RBSTFS-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 12 3/4" 18" 19" 69"

FPB-33RBSTFS-P 36 1/4" 34" - 35 1/4" 33" 2 3/4” 12 3/4" 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

ROUND TFS SYSTEMS

MODEL FACTORY ORIFICEBTU OUTPUT

ON HIGHBTU OUTPUT

ON LOW

FPB-19RBSTFS-N #19 80,000 45,000

FPB-19RBSTFS-P #36 79,000 47,400

FPB-25RBSTFS-N #7 105,000 51,000

FPB-25RBSTFS-P #31 100,000 49,500

FPB-29RBSTFS-N #7 105,000 51,000

FPB-29RBSTFS-P #31 100,000 49,500

FPB-33RBSTFS-N #7 105,000 51,000

FPB-33RBSTFS-P #31 100,000 49,500

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

Page 19: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

19

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-19RBSTMS-N 22” 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8” 15 1/2” 14” 57"

FPB-19RBSTMS-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8” 15 1/2” 14” 57"

FPB-25RBSTMS-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8” 18" 16” 54”

FPB-25RBSTMS-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8” 18" 16” 54”

FPB-29RBSTMS-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8” 18" 19" 69"

FPB-29RBSTMS-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8” 18" 19" 69"

FPB-33RBSTMS-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 6 5/8” 18" 19" 69"

FPB-33RBSTMS-P 36 1/4" 34" - 35 1/4" 33" 2 3/4” 6 5/8” 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-013.

ROUND STAINLESS STEEL TMS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-013

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTMS-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

14"

54"2 3/4" 18" 54"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#29 65,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,50065,00065,50065,00065,50065,000

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTMS-PFPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

6 5/8"

15 1/2"

16"16"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-19RBSTMS-P

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

FPB-19RBSTMS-NFPB-19RBSTMS-PFPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

LPK#41

LPK#41

LPK#41

6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"14"15 1/2"

28" 25 1/4" - 27 1/2" 25"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-013.

ROUND STAINLESS STEEL TMS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-013

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTMS-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

14"

54"2 3/4" 18" 54"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#29 65,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,50065,00065,50065,00065,50065,000

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTMS-PFPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

6 5/8"

15 1/2"

16"16"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-19RBSTMS-P

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

FPB-19RBSTMS-NFPB-19RBSTMS-PFPB-25RBSTMS-N

FPB-29RBSTMS-N

FPB-33RBSTMS-N

FPB-25RBSTMS-P

FPB-29RBSTMS-P

FPB-33RBSTMS-P

LPK#41

LPK#41

LPK#41

6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 57"14"15 1/2"

28" 25 1/4" - 27 1/2" 25"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.

FPB-19RBSTMS-N #29 65,500 LPK#41

FPB-19RBSTMS-P #41 65,000 -

FPB-25RBSTMS-N #29 65,500 LPK#41

FPB-25RBSTMS-P #41 65,000 -

FPB-29RBSTMS-N #29 65,500 LPK#41

FPB-29RBSTMS-P #41 65,000 -

FPB-33RBSTMS-N #29 65,500 LPK#41

FPB-33RBSTMS-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

ROUND TMS SYSTEMS

Page 20: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

20

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-16RBSMT-N 18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 6 3/8" 15 1/2" 14" 57"

FPB-16RBSMT-P 18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 6 3/8" 15 1/2" 14" 57"

FPB-19RBSMT-N 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8" 18" 16" 54"

FPB-19RBSMT-P 22" 19 1/4" - 21 1/2" 19" 2 3/4" 6 5/8" 18" 16" 54"

FPB-25RBSMT-N 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8" 18" 19" 69"

FPB-25RBSMT-P 28" 25 1/4" - 27 1/2" 25" 2 3/4" 6 5/8" 18" 19" 69"

FPB-29RBSMT-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 19" 69"

FPB-29RBSMT-P 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 19" 69"

FPB-33RBSMT-N 36 1/4" 34" - 35 1/4" 33" 2 3/4" 6 5/8" 18" 19" 69"

FPB-33RBSMT-P 36 1/4" 34" - 35 1/4" 33” 2 3/4" 6 5/8" 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.

FPB-16RBSMT-N #35 45,000 LPK#47

FPB-16RBSMT-P #47 45,500 -

FPB-19RBSMT-N #29 65,000 LPK#41

FPB-19RBSMT-P #41 65,000 -

FPB-25RBSMT-N #29 65,000 LPK#41

FPB-25RBSMT-P #41 65,000 -

FPB-29RBSMT-N #29 65,000 LPK#41

FPB-29RBSMT-P #41 65,000 -

FPB-33RBSMT-N #29 65,000 LPK#41

FPB-33RBSMT-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

ROUND MT SYSTEMS

Page 21: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

21

ROUND OPTIONAL ACCESSORIES

TFS OPTIONAL ACCESSORIESTM-R-AF1TX Wireless wall mount timer (30/60/120min)

1001D-AF1TX Wireless wall mount switch (On/Off)

1322WT Wireless wall mount switch (On/Off/High/Low)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT

Stainless Steel lids with brushed finished

TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate

label sticker and instructions. For use with FPB-19,25/29/33RBSTMS-N

MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery

MT OPTIONAL ACCESSORIESLPK#47 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label

sticker and instructions. For use with FPB-16RBSMT-N, 45,000 Btu

LPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-19/25/29/33RBSMT-N, 65,000 Btu

MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery

LIDS

Home/Pool automation transmitter system (works with most manufacturers systems)

WINDSHIELDS Tempered glass windshields

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

WS Wired wall mount switch (On/Off)

Page 22: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

22

SQUARE BURNER SYSTEMS SPECIFICATIONS

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-20SBSTFS-N 22" X 22" 20 1/4" - 21 3/4" 20" 2 3/4" 12 3/4" 18" 16" 54"

FPB-20SBSTFS-P 22" X 22" 20 1/4" - 21 3/4" 20" 2 3/4" 12 3/4" 18" 16" 54"

FPB-26SBSTFS-N 28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 12 3/4" 18" 19" 69"

FPB-26SBSTFS-P 28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 12 3/4" 18" 19" 69"

FPB-32SBSTFS-N 34" X 34" 32 1/4" - 33 3/4" 32" 2 3/4" 12 3/4" 18" 19" 69"

FPB-32SBSTFS-P 34" X 34" 32 1/4" - 33 3/4" 32" 2 3/4" 12 3/4" 18" 19" 69"

FPB-38SBSTFS-N 40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 12 3/4" 18" 19" 69"

FPB-38SBSTFS-P 40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 12 3/4" 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

MODEL FACTORY ORIFICEBTU OUTPUT

ON HIGHBTU OUTPUT

ON LOW

FPB-20SBSTFS-N #19 80,000 48,000

FPB-20SBSTFS-P #36 79,000 47,400

FPB-26SBSTFS-N #7 105,000 51,000

FPB-26SBSTFS-P #31 100,000 49,500

FPB-32SBSTFS-N #7 105,000 51,000

FPB-32SBSTFS-P #31 100,000 49,500

FPB-38SBSTFS-N #7 105,000 51,000

FPB-38SBSTFS-P #31 100,000 49,500

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

SQUARE TFS SYSTEMS

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

Page 23: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

23

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-20SBSTMS-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"

FPB-20SBSTMS-P 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"

FPB-26SBSTMS-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”

FPB-26SBSTMS-P 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”

FPB-32SBSTMS-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19” 69"

FPB-32SBSTMS-P 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19" 69"

FPB-38SBSTMS-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 19" 69"

FPB-38SBSTMS-P 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4” 6 5/8” 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.

SQUARE STAINLESS STEEL TMS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-026

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,50065,00065,50065,00065,50065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTMS-N

FPB-32SBSTMS-N

FPB-38SBSTMS-N

FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSTMS-P

FPB-26SBSTMS-P

FPB-32SBSTMS-P

FPB-38SBSTMS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.

SQUARE STAINLESS STEEL TMS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-026

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,50065,00065,50065,00065,50065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTMS-N

FPB-32SBSTMS-N

FPB-38SBSTMS-N

FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSTMS-P

FPB-26SBSTMS-P

FPB-32SBSTMS-P

FPB-38SBSTMS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-026.

SQUARE STAINLESS STEEL TMS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-026

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTMS-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,500

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,50065,00065,50065,00065,50065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTMS-N

FPB-32SBSTMS-N

FPB-38SBSTMS-N

FPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTMS-NFPB-20SBSTMS-PFPB-26SBSTMS-NFPB-26SBSTMS-PFPB-32SBSTMS-NFPB-32SBSTMS-PFPB-38SBSTMS-NFPB-38SBSTMS-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSTMS-P

FPB-26SBSTMS-P

FPB-32SBSTMS-P

FPB-38SBSTMS-P

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.

FPB-20SBSTMS-N #29 65,500 LPK#41

FPB-20SBSTMS-P #41 65,000 -

FPB-26SBSTMS-N #29 65,500 LPK#41

FPB-26SBSTMS-P #41 65,000 -

FPB-32SBSTMS-N #29 65,500 LPK#41

FPB-32SBSTMS-P #41 65,000 -

FPB-38SBSTMS-N #29 65,500 LPK#41

FPB-38SBSTMS-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

SQUARE TMS SYSTEMS

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

Page 24: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

24

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-20SBSMT-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"

FPB-20SBSMT-P 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 16” 54"

FPB-26SBSMT-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”

FPB-26SBSMT-P 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 19” 69”

FPB-32SBSMT-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19” 69"

FPB-32SBSMT-P 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 19" 69"

FPB-38SBSMT-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 19" 69"

FPB-38SBSMT-P 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4” 6 5/8” 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.

SQUARE STAINLESS STEEL MT BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-030

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,00065,00065,00065,00065,00065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSMT-N

FPB-32SBSMT-N

FPB-38SBSMT-N

FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSMT-P

FPB-26SBSMT-P

FPB-32SBSMT-P

FPB-38SBSMT-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.

SQUARE STAINLESS STEEL MT BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-030

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,00065,00065,00065,00065,00065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSMT-N

FPB-32SBSMT-N

FPB-38SBSMT-N

FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSMT-P

FPB-26SBSMT-P

FPB-32SBSMT-P

FPB-38SBSMT-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.

SQUARE STAINLESS STEEL MT BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-030

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,00065,00065,00065,00065,00065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSMT-N

FPB-32SBSMT-N

FPB-38SBSMT-N

FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSMT-P

FPB-26SBSMT-P

FPB-32SBSMT-P

FPB-38SBSMT-P

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.

FPB-20SBSMT-N #29 65,500 LPK#41

FPB-20SBSMT-P #41 65,000 -

FPB-26SBSMT-N #29 65,500 LPK#41

FPB-26SBSMT-P #41 65,000 -

FPB-32SBSMT-N #29 65,500 LPK#41

FPB-32SBSMT-P #41 65,000 -

FPB-38SBSMT-N #29 65,500 LPK#41

FPB-38SBSMT-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

SQUARE MT SYSTEMS

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-022.

SQUARE STAINLESS STEEL TFS BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-022

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 06/23/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSTFS-N 12 3/4"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"12 3/4"

18"18"

19"19"

48,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSTFS-N

FPB-32SBSTFS-N

FPB-38SBSTFS-N

FPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSTFS-NFPB-20SBSTFS-PFPB-26SBSTFS-NFPB-26SBSTFS-PFPB-32SBSTFS-NFPB-32SBSTFS-PFPB-38SBSTFS-NFPB-38SBSTFS-P

FPB-20SBSTFS-P

FPB-26SBSTFS-P

FPB-32SBSTFS-P

FPB-38SBSTFS-P

Page 25: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

25

TFS OPTIONAL ACCESSORIES

TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating

plate label sticker and instructions. For use with FPB-20/26/32/38SBSMT-N, 65,000 Btu

MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery

MT OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating

plate label sticker and instructions. For use with FPB-20/26/32/38SBSMT-N, 65,000 Btu

MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery

TM-R-AF1TX Wireless wall mount timer (30/60/120min)

1001D-AF1TX Wireless wall mount switch (On/Off)

1322WT Wireless wall mount switch (On/Off/High/Low)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

SQUARE OPTIONAL ACCESSORIES

WS Wired wall mount switch (On/Off)

Page 26: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

26

FLAT DISC BURNER SYSTEMS SPECIFICATIONS

MODEL

OUTSIDE DIM.

A

HEIGHT OF SPUR

B

DIM. FROM BOTTOM OF DISC TO BOTTOM

OF APPLIANCEC

CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN

D

CLEARANCE TO A COMBUSTABLE

SIDEWALLE

CLEARANCE TO A COMBUSTABLE

CEILINGF

FPB-29DBSTFS-N 29” 1" 10 1/4” 18" 19" 69"

FPB-29DBSTFS-P 29” 1” 10 1/4” 18" 19" 69"

FPB-34DBSTFS-N 34” 1" 10 1/4” 18" 19" 69"

FPB-34DBSTFS-P 34” 1” 10 1/4” 18" 19" 69"

FPB-44DBSTFS-N 44” 1” 10 1/4” 18" 19" 69"

FPB-44DBSTFS-P 44” 1” 10 1/4” 18" 19" 69"

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.

FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-034

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#7 105,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#31#7#31

100,000105,000100,000

A

B

A

C

D

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

18"18"

19"19"

51,000

BTU OUTPUTON LOW

49,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

10 1/4"10 1/4"10 1/4"

FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

69"69"

FPB-44DBSTFS-N

FPB-34DBSTFS-P

FPB-44DBSTFS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.

FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-034

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#7 105,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#31#7#31

100,000105,000100,000

A

B

A

C

D

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

18"18"

19"19"

51,000

BTU OUTPUTON LOW

49,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

10 1/4"10 1/4"10 1/4"

FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

69"69"

FPB-44DBSTFS-N

FPB-34DBSTFS-P

FPB-44DBSTFS-P

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-034.

FLAT DISC STAINLESS STEEL TFS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-034

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTFS-N 34" 24" - 34" 1" 10 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#7 105,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#31#7#31

100,000105,000100,000

A

B

A

C

D

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

18"18"

19"19"

51,000

BTU OUTPUTON LOW

49,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

10 1/4"10 1/4"10 1/4"

FPB-34DBSTFS-NFPB-34DBSTFS-PFPB-44DBSTFS-NFPB-44DBSTFS-P

69"69"

FPB-44DBSTFS-N

FPB-34DBSTFS-P

FPB-44DBSTFS-P

MODEL FACTORY ORIFICEBTU OUTPUT

ON HIGHBTU OUTPUT

ON LOW

FPB-29DBSTFS-N #7 105,000 51,000

FPB-29DBSTFS-P #31 100,000 49,500

FPB-34DBSTFS-N #7 105,000 51,000

FPB-34DBSTFS-P #31 100,000 49,500

FPB-44DBSTFS-N #7 105,000 51,000

FPB-44DBSTFS-P #31 100,000 49,500

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

DISC TFS SYSTEMS

2-inch minimum overlap per side required to secure disc

B

CD

E

F

Page 27: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

27

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-036.

FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-036

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

69"69"

FPB-44DBSTMS-N

FPB-34DBSTMS-P

FPB-44DBSTMS-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-036.

FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-036

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

69"69"

FPB-44DBSTMS-N

FPB-34DBSTMS-P

FPB-44DBSTMS-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-036.

FLAT DISC STAINLESS STEEL TMS BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-036

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSTMS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSTMS-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSTMS-NFPB-34DBSTMS-PFPB-44DBSTMS-NFPB-44DBSTMS-P

69"69"

FPB-44DBSTMS-N

FPB-34DBSTMS-P

FPB-44DBSTMS-P

3 7/8"3 7/8"3 7/8"

LPK#41

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.

FPB-29DBSTMS-N #29 65,500 LPK#41

FPB-29DBSTMS-N #41 65,500 -

FPB-34DBSTMS-N #29 65,500 LPK#41

FPB-34DBSTMS-P #41 65,000 -

FPB-44DBSTMS-N #29 65,500 LPK#41

FPB-44DBSTMS-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

MODEL

OUTSIDE DIM.

A

HEIGHT OF SPUR

B

DIM. FROM BOTTOM OF DISC TO BOTTOM

OF APPLIANCEC

CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN

D

CLEARANCE TO A COMBUSTABLE

SIDEWALLE

CLEARANCE TO A COMBUSTABLE

CEILINGF

FPB-29DBSTMS-N 29” 1" 3 7/8” 18" 19" 69"

FPB-29DBSTMS-P 29” 1” 3 7/8” 18" 19" 69"

FPB-34DBSTMS-N 34” 1" 3 7/8” 18" 19" 69"

FPB-34DBSTMS-P 34” 1” 3 7/8” 18" 19" 69"

FPB-44DBSTMS-N 44” 1” 3 7/8” 18" 19" 69"

FPB-44DBSTMS-P 44” 1” 3 7/8” 18" 19" 69"

DISC TMS SYSTEMS

2-inch minimum overlap per side required to secure disc

B

CD

E

F

Page 28: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

28

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.

FPB-29DBSMT-N #29 65,500 LPK#41

FPB-29DBSMT-P #41 65,000 -

FPB-34DBSMT-N #29 65,500 LPK#41

FPB-34DBSMT-P #41 65,000 -

FPB-44DBSMT-N #29 65,500 LPK#41

FPB-44DBSMT-P #41 65,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

MODEL

OUTSIDE DIM.

A

HEIGHT OF SPUR

B

DIM. FROM BOTTOM OF DISC TO BOT-

TOM OF APPLIANCEC

CLEARANCE TO A COMBUSTABLE FLOOR FROM THE LIP OF PAN

D

CLEARANCE TO A COMBUSTABLE

SIDEWALLE

CLEARANCE TO A COMBUSTABLE

CEILINGF

FPB-29DBSMT-N 29” 1" 3 7/8” 18" 19" 69"

FPB-29DBSMT-P 29” 1” 3 7/8” 18" 19" 69"

FPB-34DBSMT-N 34” 1" 3 7/8” 18" 19" 69"

FPB-34DBSMT-P 34” 1” 3 7/8” 18" 19" 69"

FPB-44DBSMT-N 44” 1” 3 7/8” 18" 19" 69"

FPB-44DBSMT-P 44” 1” 3 7/8” 18" 19" 69"

DISC MT SYSTEMS

2-inch minimum overlap per side required to secure disc

B

CD

E

F

Page 29: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

29

FLAT DISC OPTIONAL ACCESSORIES

TFS OPTIONAL ACCESSORIES

TMS OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate

label sticker and instructions. For use with FPB-29,34,44DBSTMS-N, 65,000 Btu

MSI-BSTMS Manual Spark Ignition Kit for FPB Series TMS Systems featuring the Burning Spur. Kit. Includes: Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition wiring, AAA Battery

MT OPTIONAL ACCESSORIESLPK#41 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate

label sticker and instructions. For use with FPB-29,34/44DBSMT-N, 65,000 Btu

MSI-BSMTI Manual Spark Ignition Kit for FPB Series Match Throw Systems featuring the Burning Spur. Kit includes: Mounting Plate, Spark Igniter Module, Ignition Hood, Ignition Hood Screen, Ignition Rain Shield, 2-Probe Spark Igniter, Burner Rain Shield and Bracket, Ignition Wiring, AAA Battery

TM-R-AF1TX Wireless wall mount timer (30/60/120min)

1322WT Wireless wall mount switch (On/Off/High/Low)

1001D-AF1TX Wireless wall mount switch (On/Off)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

WS Wired wall mount switch (On/Off)

Page 30: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

30

L SERIES BURNER SYSTEMS SPECIFICATIONS

5053-041

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.

LINEAR TFS BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.

FPB-L24TFS-N

LP GAS:

15" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24TFS-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#38 53K 20K LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#35#47

0.125"#43

35K 22K42K 23K42K 30K55K 37K55K 37K

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

8 1/2" 5 3/4"

6 1/4"

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"

FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

FPB-L30TFS-N

FPB-L36TFS-N

FPB-L24TFS-P

FPB-L30TFS-P

FPB-L36TFS-P

5053-041

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.

LINEAR TFS BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.

FPB-L24TFS-N

LP GAS:

15" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24TFS-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#38 53K 20K LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#35#47

0.125"#43

35K 22K42K 23K42K 30K55K 37K55K 37K

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

8 1/2" 5 3/4"

6 1/4"

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"

FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

FPB-L30TFS-N

FPB-L36TFS-N

FPB-L24TFS-P

FPB-L30TFS-P

FPB-L36TFS-P

MODEL

OVERALL LENGTH OF

CRADLEA

OVERALL WIDTH OF CRADLE

B

MIN/MAX CUT OUT LENGTH

C

MIN/MAX CUT OUT LENGTH

D

INSIDE PAN LENGTH

E

INSIDE PAN WIDTH

FPAN DEPTH

G

OVERALL HEIGHT OF APPLIANCE

H

FPB-24LTFS-N 28 1/4” 6 7/8" 28 1/2” 7 1/8" 24” 6 3/8” 4 1/4” 12 3/4"

FPB-24LTFS-P 28 1/4” 6 7/8" 28 1/2” 7 1/8” 24” 6 3/8” 4 1/4” 12 3/4”

FPB-30LTFS-N 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 12 3/4”

FPB-30LTFS-P 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 12 3/4”

FPB-36LTFS-N 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 12 3/4”

FPB-36LTFS-P 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 12 3/4”

5053-041

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-041.

LINEAR TFS BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WCFOR NATURAL GAS (NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNER ORIFICE. FLEX LINESIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLYFROM THE LISTED BTU SPECIFICATIONS.

FPB-L24TFS-N

LP GAS:

15" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24TFS-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#38 53K 20K LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#35#47

0.125"#43

35K 22K42K 23K42K 30K55K 37K55K 37K

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

8 1/2" 5 3/4"

6 1/4"

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

12 3/4"FPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 12 3/4"

FPB-L24TFS-NFPB-L24TFS-PFPB-L30TFS-NFPB-L30TFS-PFPB-L36TFS-NFPB-L36TFS-P

FPB-L30TFS-N

FPB-L36TFS-N

FPB-L24TFS-P

FPB-L30TFS-P

FPB-L36TFS-P

MODEL FACTORY ORIFICEBTU OUTPUTHIGH LOW

CONVERSION KIT PART NO.

FPB-24LTFS-N #38 35K 20K LPK#50

FPB-24LTFS-P #50 35K 22K -

FPB-30LTFS-N #35 42K 23K LPK#48

FPB-30LTFS-P #47 42K 30K -

FPB-36LTFS-N 0.125” 55K 37K LPK#44

FPB-36LTFS-P #43 55K 37K -

BTU SPECS

PRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

L SERIES TFS SYSTEMS

Page 31: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

31

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

MODEL

OVERALL LENGTH OF

CRADLEA

OVERALL WIDTH OF CRADLE

B

MIN/MAX CUT OUT LENGTH

C

MIN/MAX CUT OUT LENGTH

D

INSIDE PAN LENGTH

E

INSIDE PAN WIDTH

FPAN DEPTH

G

OVERALL HEIGHT OF APPLIANCE

H

FPB-24LMT-N 28 1/4” 6 7/8" 28 1/2” 7 1/8" 24” 6 3/8” 4 1/4” 4 3/4"

FPB-24LMT-P 28 1/4” 6 7/8" 28 1/2” 7 1/8” 24” 6 3/8” 4 1/4” 4 3/4”

FPB-30LMT-N 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 4 3/4”

FPB-30LMT-P 34 1/4” 6 7/8” 34 1/2” 7 1/8” 30” 6 3/8” 4 1/4” 4 3/4”

FPB-36LMT-N 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 4 3/4”

FPB-36LMT-P 40 1/4” 6 7/8” 40 1/2” 7 1/8” 36” 6 3/8” 4 1/4” 4 3/4”

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.

FPB-24LMT-N #42 35,000 LPK#50

FPB-24LMT-P #50 35,000 -

FPB-30LMT-N #38 45,000 LPK#48

FPB-30LMT-P #48 45,000 -

FPB-36LMT-N #32 55,000 LPK#44

FPB-36LMT-P #44 55,000 -

BTU SPECS

PRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

L SERIES MT SYSTEMS

Page 32: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

32

COMBINING THE L SERIES

Bring the two ends together that you removed the brackets from

Locate and remove the extension bracket on both burners

Connecting two (2) MT units

Connecting two (2) TFS units

Page 33: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

33

Here are the possible combinations.

Model + Model = Minimum Rough Opening Total BTU’s NG Total BTU’s LPFPB-36LTFS + FPB-36LTFS = 76.25” long x 7 1/8” wide 110,000 110,000

FPB-36LMT + FPB-36LMT = 76.25” long x 7 1/8” wide 104,000 104,000

FPB-36LTFS + FPB-30LTFS = 70.25” long x 7 1/8” wide 97,000 97,000

FPB-36LMT + FPB-30LMT = 70.25” long x 7 1/8” wide 97,000 100,000

FPB-36LTFS + FPB-24LTFS = 64.25” long x 7 1/8” wide 90,000 90,000

FPB-36LMT + FPB-24LMT = 64.25” long x 7 1/8” wide 87,000 90,000

FPB30LTFS + FPB30LTFS = 64.25” long x 7 1/8” wide 84,000 84,000

FPB30LMT + FPB30LMT = 64.25” long x 7 1/8” wide 90,000 90,000

FPB30LTFS + FPB24LTFS = 56.25” long x 7 1/8” wide 77,000 77,000

FPB30LMT + FPB24LMT = 56.25” long x 7 1/8” wide 80,000 80,000

FPB-24LTFS + FPB-24LTFS = 52.25” long x 7 1/8” wide 70,000 70,000

L SERIES OPTIONAL ACCESSORIES

LPK#50 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-24LMT-N, 40,000 Btu

LPK#48 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-30LMT-N, 47,000 Btu

LPK#44 Liquid Propane (LP) Conversion Kit. Converts fire pit from Natural Gas to LP Gas. Includes: Orifice/Air Shutter, rating plate label sticker and instructions. For use with FPB-36LMT-N, 60,000 Btu

TRIM-L24 3/4” stainless steel decorative trim fits FPB-24L Series

TRIM-L30 3/4” stainless steel decorative trim fits FPB-30L Series

TRIM-L36 3/4” stainless steel decorative trim fits FPB-36L Series

TRIM-L48 3/4” stainless steel decorative trim fits (2) FPB-24L Series end to end

TRIM-L60 3/4” stainless steel decorative trim fits (2) FPB-30L Series end to end

TRIM-L72 3/4” stainless steel decorative trim fits (2) FPB-36L Series end to end

TM-R-AF1TX Wireless wall mount timer (30/60/120min)

1001D-AF1TX Wireless wall mount switch (On/Off)

1322WT Wireless wall mount switch (On/Off/High/Low)

AF-4000ADP24(80) 110 volts AC adapter, coverts to 7.5 DC volts for TFS systems

AF-4000HAT Home/Pool automation transmitter system (works with most manufacturers systems)

LIDS Stainless Steel lids with brushed finished

WINDSHIELDS Tempered glass windshields

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

WS Wired wall mount switch (On/Off)

TRIM (OPTIONAL ACCESSORY)

The clearance to combustible material for combined burners is the same as each individual burner. Please refer to individual burner list for clearance to combustible material

WIRING A SWITCH TO COMBINED BURNERS

MODULE MODULE

OFF

CONNECTION CONNECTION

When wiring (2) two L Series burners to the same switch, a two-pole switch is required (refer to diagram as an example). Maximum length 50’ of 18 gauge or larger wire, suitable for outdoor appliances - always refer to your local codes.

Access control module from the valve box and locate the brown wires.

Slide the switch on the control module from Remote to Off.

Connect the two brown wires to the 18 (or larger) gauge wire by connecting to the 1/4” terminals on the brown wires.

Connect the other end of the wire to one side of the two-pole switch.

Page 34: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

34

NON-LISTED BURNER SYSTEMS SPECIFICATIONS

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-19RBS16MT-N 22” 19 1/4” - 21 1/2” 19" 2 3/4" 6 5/8" 18” 36” 96"

FPB-25RBS22MT-N 28” 25 1/4" - 27 1/2" 25" 2 3/4” 6 5/8" 18" 36” 96”

FPB-29RBS22MT-N 32 1/4" 30" - 31 3/8" 29" 2 3/4" 6 5/8" 18" 36” 96”

FPB-33RBS31MT-N 36 1/4” 34” - 35 1/4” 33" 2 3/4" 6 5/8" 18" 36” 96”

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

MODEL FACTORY ORIFICE BTU OUTPUT CONVERSION

FPB-19RBS16MT-N #31 60,000 OAS-LP45

FPB-19RBS16MT-P #45 55,500 -

FPB-25RBS22MT-N #22 100,000 OAS-LP35

FPB-25RBS22MT-P #35 99,000 -

FPB-29RBS22MT-N #22 100,000 OAS-LP35

FPB-29RBS22MT-P #35 99,000 -

FPB-33RBS31MT-N #08 160,000 OAS-LP29

FPB-33RBS31MT-P #29 150,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NON-LISTEDROUND MT SYSTEMS

OAS-LP45 Propane Conversion Kit (Orifice/Air Shutter) for 16” Burning Spur, 55,000 Btu

OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu

OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

OPTIONAL ACCESSORIES

These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.

Page 35: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

35

MODEL

OUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAX CUT OUT DIM.

B

INSIDE PAN DIM.

C

PAN DEPTH

D

OVERALL APPLIANCE

HEIGHTE

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

F

CLEARANCE TO A

COMBUSTABLE SIDEWALL

G

CLEARANCE TO A

COMBUSTABLE CEILING

H

FPB-20SBS16MT-N 22” X 22” 20 1/4” - 21 3/4” 20" 2 3/4" 6 5/8” 18” 36” 96"

FPB-26SBS22MT-N 28” X 28” 26 1/4” - 27 3/4” 26" 2 3/4" 6 5/8” 18" 36” 96”

FPB-32SBS31MT-N 34” X 34” 32 1/4” - 33 3/4” 32" 2 3/4" 6 5/8” 18" 36” 96”

FPB-38SBS36MT-N 40” X 40” 38 1/4” - 39 3/4” 38" 2 3/4" 6 5/8” 18" 36” 96”

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-030.

SQUARE STAINLESS STEEL MT BURNER SYSTEMS

SQUARE BURNER SYSTEMS

5053-030

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-20SBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-20SBSMT-N 6 5/8"22" X 22" 20 1/4" - 21 3/4" 20" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

20" 54"28" X 28" 26 1/4" - 27 3/4" 26" 2 3/4" 18"

16"

69"26" 2 3/4" 18"

16"

69"34" X 34" 32" 2 3/4" 18" 19" 69"

32" 2 3/4" 18" 19" 69"40" X 40" 38 1/4" - 39 3/4" 38" 2 3/4" 18" 19" 69"

38" 2 3/4" 18" 19" 69"

#29 65,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT

#41#29#41#29#41#29#41

65,00065,00065,00065,00065,00065,00065,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

32 1/4" - 33 3/4"

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-26SBSMT-N

FPB-32SBSMT-N

FPB-38SBSMT-N

FPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

22" X 22"

28" X 28"

34" X 34"

40" X 40"

20 1/4" - 21 3/4"

26 1/4" - 27 3/4"

38 1/4" - 39 3/4"

32 1/4" - 33 3/4"

2 3/4"2 3/4"

FPB-20SBSMT-NFPB-20SBSMT-PFPB-26SBSMT-NFPB-26SBSMT-PFPB-32SBSMT-NFPB-32SBSMT-PFPB-38SBSMT-NFPB-38SBSMT-P

6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"6 5/8"

LPK#41

LPK#41

LPK#41

FPB-20SBSMT-P

FPB-26SBSMT-P

FPB-32SBSMT-P

FPB-38SBSMT-P

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART N0.

FPB-20SBS16MT-N #31 60,000 OAS-LP45

FPB-20SBS16MT-P #45 55,000 -

FPB-26SBS22MT-N #22 100,000 OAS-LP35

FPB-26SBS22MT-P #35 99,000 -

FPB-32SBS31MT-N #08 160,000 OAS-LP29

FPB-32SBS31MT-P #41 150,000 -

FPB-38SBS36MT-N #03 183,000 OAS-LP25

FPB-38SBS36MT-P #41 182,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

NON-LISTEDSQUARE MT SYSTEMS

OAS-LP45 Propane Conversion Kit (Orifice/Air Shutter) for 16” Burning Spur, 55,000 Btu

OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu

OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu

OAS-LP25 Propane Conversion Kit (Orifice/Air Shutter) for 36” Burning Spur, 182,000 Btu

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

OPTIONAL ACCESSORIES

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-017.

ROUND STAINLESS STEEL MT BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-017

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

TOP VIEW

FPB-16RBSMT-N

LP GAS:

FPB-16RBSMT-P

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-16RBSMT-N 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

FPB-16RBSMT-P 6 3/8"18 1/2" 16 1/2" - 17 1/4" 16" 2 1/2" 15 1/2" 14" 57"FPB-19RBSMT-N 6 5/8"22" 19 1/4" - 21 1/2" 19" 2 3/4" 18" 16" 54"FPB-19RBSMT-P 6 5/8"22" 19" 2 3/4" 18" 16" 54"FPB-25RBSMT-N 6 5/8"28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 19" 69"FPB-25RBSMT-P 6 5/8"28" 25" 2 3/4" 18" 19" 69"FPB-29RBSMT-N 6 5/8"32 1/4" 30" - 31 3/8" 29" 2 3/4" 18" 19" 69"FPB-29RBSMT-P 6 5/8"32 1/4" 29" 2 3/4" 18" 19" 69"FPB-33RBSMT-N 6 5/8"36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"FPB-33RBSMT-P 6 5/8"36 1/4" 33" 2 3/4" 18" 19" 69"

19 1/4" - 21 1/2"

25 1/4" - 27 1/2"

30" - 31 3/8"

34" - 35 1/4"

FPB-19RBSMT-N FPB-19RBSMT-P

FPB-25RBSMT-N FPB-25RBSMT-P

FPB-29RBSMT-N FPB-29RBSMT-P

FPB-33RBSMT-N FPB-33RBSMT-P

FPB-16RBSMT-N #35 45,000 LPK#47

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUT CONVERSION

FPB-16RBSMT-PFPB-19RBSMT-NFPB-19RBSMT-PFPB-25RBSMT-NFPB-25RBSMT-PFPB-29RBSMT-NFPB-29RBSMT-PFPB-33RBSMT-NFPB-33RBSMT-P

#47#29#41#29#41#29#41#29#41

45,50065,00065,00065,00065,00065,00065,00065,00065,000

LPK#41

LPK#41

LPK#41

LPK#41

AC

CBA

DE

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.

Page 36: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

36

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-039.

FLAT DISC STAINLESS STEEL MT BURNER SYSTEMS

FLAT DISC BURNER SYSTEMS

5053-039

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.REVISION DATE 05/25/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-34DBSMT-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-34DBSMT-N 34" 24" - 34" 1" 3 7/8"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE

DIM.A

MIN - MAXSPUR VIEW DIM.

B

HEIGHTOF SPUR

C

DIM. FROM BOTTOMOF DISC TO BOTTOM

OF APPLIANCED

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

34" 24" - 34" 1"44" 24" - 44" 1" 18"

19"

69"44" 1" 18"

19"

69"24" - 44"

#29 65,500

MODEL BTUSPECIFICATIONS FACTORY ORFICE BTU OUTPUT

#41#29#41

65,00065,50065,000

A

BA

C

D

MIN. INLET 5.0" WC 10.5" WCPRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

18"18"

19"19"

LPK#41

CONVERSIONKIT PART NO.

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FORNATURAL GAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) ATTHE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPESIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'SMAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

FPB-34DBSMT-NFPB-34DBSMT-PFPB-44DBSMT-NFPB-44DBSMT-P

69"69"

FPB-44DBSMT-N

FPB-34DBSMT-P

FPB-44DBSMT-P

3 7/8"3 7/8"3 7/8"

LPK#41

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.

FPB-29DBS22MT-N #22 100,000 OAS-LP35

FPB-29DBS22MT-P #35 99,000 -

FPB-34DBS22MT-N #22 100,000 OAS-LP35

FPB-34DBS22MT-P #35 99,000 -

FPB-34DBS31MT-N #08 160,000 OAS-LP29

FPB-34DBS31MT-P #29 150,000 -

FPB-44DBS36MT-N #03 183,000 OAS-LP25

FPB-44DBS36MT-P #25 182,000 -

BTU SPECSPRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

NOTES:1. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO THE VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.2. THESE FIRE PITS ARE SOLD AS NATURAL OR LP GAS MODELS. YOU MUST ORDER THE SPECIFIC MODEL PER THE APPLICATION. THESE ARE NOT FIELD CONVERTIBLE.3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-009.

ROUND STAINLESS STEEL TFS BURNER SYSTEMS

ROUND BURNER SYSTEMS

5053-009

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

SELECT DESIRED SYSTEM:

NATURAL GAS:

FRONT VIEW

TOP VIEW

FPB-19RBSTFS-N

LP GAS:

F

G

H

CLEARANCE TO COMBUSTIBLES

FPB-19RBSTFS-N 12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOUTSIDE DIM.

(INCLUDING LIP)A

MIN - MAXCUT OUT DIM.

B

INSIDEPAN DIM.

C

PANDEPTH

D

OVERALLAPPLIANCE

HEIGHTE

CLEARANCE TO ACOMBUSTIBLE FLOOR

FROM THE LIP OF THE PANF

CLEARANCE TO ACOMBUSTIBLE

SIDEWALLG

CLEARANCE TOA COMBUSTIBLE

CEILINGH

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18"

16"

69"

32 1/4" 29" 2 3/4" 18" 19" 69"29" 2 3/4" 18" 19" 69"

36 1/4" 34" - 35 1/4" 33" 2 3/4" 18" 19" 69"33" 2 3/4" 18" 19" 69"

#19 80,000

MODEL BTUSPECIFICATIONS

FACTORY ORFICEBTU OUTPUT

ON HIGH

#36#7#31#7#31#7#31

79,000105,000100,000105,000100,000105,000100,000

AC

CBA

D

E

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

FPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

32 1/4"

36 1/4"

30" - 31 3/8"30" - 31 3/8"

34" - 35 1/4"

12 3/4"

12 3/4"12 3/4"12 3/4"12 3/4"

18"

19"

FPB-19RBSTFS-NFPB-19RBSTFS-PFPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

45,000

BTU OUTPUTON LOW

47,40051,00049,50051,00049,50051,00049,500

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0" WC FOR NATURALGAS (NG) AND 11.0" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSOAFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

FPB-25RBSTFS-N

FPB-29RBSTFS-N

FPB-33RBSTFS-N

FPB-19RBSTFS-P

FPB-25RBSTFS-P

FPB-29RBSTFS-P

FPB-33RBSTFS-P

12 3/4"22" 19 1/4" - 21 1/2" 19" 2 3/4" 54"16"18"

28" 25 1/4" - 27 1/2" 25" 2 3/4" 18" 69"12 3/4" 19"

MODEL

OUTSIDE DIM.

A

MIN - MAXSPUR VIEW DIM.

B

HEIGHT OF SPUR

C

DIM. FROM BOTTOM OF DISC TO BOTTOM OF

APPLIANCED

CLEARANCE TO A COMBUSTABLE

FLOOR FROM THE LIP OF PAN

E

CLEARANCE TO A COMBUSTABLE

SIDEWALLF

CLEARANCE TO A

COMBUSTABLE CEILING

G

FPB-29DBS22MT-N 29” 24” - 34” 1" 3 7/8” 18" 36” 96”

FPB-34DBS22MT-N 34” 24” - 34” 1" 3 7/8” 18" 36” 96”

FPB-34DBS31MT-N 34” 24” - 34” 1" 3 7/8” 18" 36” 96”

FPB-44DBS36MT-N 44” 24” - 44” 1” 3 7/8” 18" 36” 96”

NON-LISTEDDISC MT SYSTEMS

OAS-LP35 Propane Conversion Kit (Orifice/Air Shutter) for 22” Burning Spur, 99,000 Btu

OAS-LP29 Propane Conversion Kit (Orifice/Air Shutter) for 31” Burning Spur, 150,000 Btu

OAS-LP25 Propane Conversion Kit (Orifice/Air Shutter) for 36” Burning Spur, 182,000 Btu

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

OPTIONAL ACCESSORIES

E

F

G

These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.

Page 37: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

37

NON-LISTEDLINE OF FIRE SYSTEMS

5053-056

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.

LINE OF FIRE MT/MSI

LINE OF FIRE

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

LOF30MT-N

6" FLOORTO BOTTOM

OF PAN

36"SIDEWALL

96" CEILING

CLEARANCE TO COMBUSTIBLES

LOF30MT-N 32 1/4"

MODELOVERALL

LENGTH OF PANA

OVERALLWIDTH OF PAN

B

INSIDE PANLENGTH

C

INSIDE PANWIDTH

D

MIN/MAX CUTOUT LENGTH

E

MIN/MAX CUTOUT WIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#36 45,000 OAS-LP49

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#29#36#29

75,00045,00075,000

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

END VIEWSIDE VIEW

TOP VIEW

8" 30"

30"

6" 30 1/4"

30 1/4"

6 1/2" 2 3/4"

32 1/4"

4"LOF36MT-NLOF30MSI-NLOF36MSI-N

38 1/4" 36"

36"

28 1/2"

34 1/2"38 1/4"

8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"

LOF36MT-N

LOF30MSI-N

3"

G H

DC

F B

E

A

LOF36MSI-N

LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N

OAS-LP41OAS-LP49OAS-LP41

60°

5053-056

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.

LINE OF FIRE MT/MSI

LINE OF FIRE

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

LOF30MT-N

6" FLOORTO BOTTOM

OF PAN

36"SIDEWALL

96" CEILING

CLEARANCE TO COMBUSTIBLES

LOF30MT-N 32 1/4"

MODELOVERALL

LENGTH OF PANA

OVERALLWIDTH OF PAN

B

INSIDE PANLENGTH

C

INSIDE PANWIDTH

D

MIN/MAX CUTOUT LENGTH

E

MIN/MAX CUTOUT WIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#36 45,000 OAS-LP49

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#29#36#29

75,00045,00075,000

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

END VIEWSIDE VIEW

TOP VIEW

8" 30"

30"

6" 30 1/4"

30 1/4"

6 1/2" 2 3/4"

32 1/4"

4"LOF36MT-NLOF30MSI-NLOF36MSI-N

38 1/4" 36"

36"

28 1/2"

34 1/2"38 1/4"

8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"

LOF36MT-N

LOF30MSI-N

3"

G H

DC

F B

E

A

LOF36MSI-N

LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N

OAS-LP41OAS-LP49OAS-LP41

60°

5053-056

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.

LINE OF FIRE MT/MSI

LINE OF FIRE

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

LOF30MT-N

6" FLOORTO BOTTOM

OF PAN

36"SIDEWALL

96" CEILING

CLEARANCE TO COMBUSTIBLES

LOF30MT-N 32 1/4"

MODELOVERALL

LENGTH OF PANA

OVERALLWIDTH OF PAN

B

INSIDE PANLENGTH

C

INSIDE PANWIDTH

D

MIN/MAX CUTOUT LENGTH

E

MIN/MAX CUTOUT WIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#36 45,000 OAS-LP49

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#29#36#29

75,00045,00075,000

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

END VIEWSIDE VIEW

TOP VIEW

8" 30"

30"

6" 30 1/4"

30 1/4"

6 1/2" 2 3/4"

32 1/4"

4"LOF36MT-NLOF30MSI-NLOF36MSI-N

38 1/4" 36"

36"

28 1/2"

34 1/2"38 1/4"

8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"

LOF36MT-N

LOF30MSI-N

3"

G H

DC

F B

E

A

LOF36MSI-N

LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N

OAS-LP41OAS-LP49OAS-LP41

60°

MODEL

OVERALL LENGTH OF

PANA

OVERALL WIDTH OF PAN

B

INSIDE PAN

LENGTHC

INSIDE PAN WIDTH

D

MIN/MAX CUT OUT LENGTH

E

MIN/MAX CUT OUT WIDTH

FPAN DEPTH

G

OVERALL HEIGHT OF APPLIANCE

H

LOF30MT-N 32 1/4” 8” 30” 6" 30 1/2” - 31 3/4” 6 1/4” - 7 1/2” 2 3/4” 4"

LOF36MT-N 38 1/4” 8” 36” 6” 36 1/2” - 37 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”

LOF30MSI-N 32 1/4” 8” 30” 6” 30 1/2” - 31 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”

LOF36MSI-N 38 1/4” 8” 36” 6” 36 1/2” - 37 3/4” 6 1/4” - 7 1/2” 2 3/4” 4”

5053-056

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-056.

LINE OF FIRE MT/MSI

LINE OF FIRE

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

LOF30MT-N

6" FLOORTO BOTTOM

OF PAN

36"SIDEWALL

96" CEILING

CLEARANCE TO COMBUSTIBLES

LOF30MT-N 32 1/4"

MODELOVERALL

LENGTH OF PANA

OVERALLWIDTH OF PAN

B

INSIDE PANLENGTH

C

INSIDE PANWIDTH

D

MIN/MAX CUTOUT LENGTH

E

MIN/MAX CUTOUT WIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#36 45,000 OAS-LP49

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#29#36#29

75,00045,00075,000

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

END VIEWSIDE VIEW

TOP VIEW

8" 30"

30"

6" 30 1/4"

30 1/4"

6 1/2" 2 3/4"

32 1/4"

4"LOF36MT-NLOF30MSI-NLOF36MSI-N

38 1/4" 36"

36"

28 1/2"

34 1/2"38 1/4"

8" 6" 7 1/8" 2 3/4" 4"8" 6" 6 1/2" 2 3/4" 4"8" 6" 7 1/8" 2 3/4" 4"

LOF36MT-N

LOF30MSI-N

3"

G H

DC

F B

E

A

LOF36MSI-N

LOF30MT-NLOF36MT-NLOF30MSI-NLOF36MSI-N

OAS-LP41OAS-LP49OAS-LP41

60°

5053-043

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. THESE FIRE PIT MODELS ARE SHIPPED AS NATURAL GAS AND MUST BE CONVERTED TO LP GAS.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING FIRE PITS .

4. ALL FIRE PIT INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS ALL GAS CONNECTIONS.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-043.

LINEAR MT BURNER SYSTEMS

LINEAR SERIES

SELECT DESIRED SYSTEM:

NATURAL GAS:

DISCLAIMER: BTU LISTINGS AREBASED ON 7.0" WC FOR NATURAL GAS(NG) AND 11.0" WC FOR LIQUIDPROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPERGAS PIPE SIZING WILL ALSO AFFECTBTU'S. AS A RESULT YOUR BTU'S MAYVARY SLIGHTLY FROM THE LISTEDBTU SPECIFICATIONS.

FPB-L24MT-N

LP GAS:

1" FLOORTO BOTTOMOF CRADLE

17"SIDEWALL

44" CEILING

CLEARANCE TO COMBUSTIBLES

FPB-L24MT-N 28 1/4"

THESE FIRE PITSARE TESTED TO

ANSI Z21.97-2014 /CSA 2.41-2014STANDARDS.

MODELOVERALL LENGTH

OF CRADLEA

OVERALL WIDTHOF CRADLE

B

MIN/MAXCUT OUTLENGTH

C

MIN/MAXCUT OUTLENGTH

D

INSIDE PANLENGTH

E

INSIDE PANWIDTH

F

PANDEPTH

G

OVERALL HEIGHTOF APPLIANCE

H

#42 35,000 LPK#50

MODEL BTUSPECIFICATIONS

FACTORY ORFICE BTU OUTPUTCONVERSION KIT

PART NO.

#50#38#48#32#44

35,00045,00045,00055,00055,000

LPK#48

LPK#44

MIN. INLET 5.0" WC 10.5" WC

PRESSURE GAS TYPE NG GAS TYPE LP

MAX. INLETNORMAL INLET

10.5" WC7.0" WC

13.0" WC11.0" WC

AC

B D

2" TYP.

23" TYP.

E

G

F

H

END VIEWSIDE VIEW

TOP VIEW

6 7/8" 28 1/2"

34 1/2"

40 1/2"

7 1/8" 24"

30"

36"

6 3/8" 4 1/4"

34 1/4"

40 1/4"

4 3/4"FPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

28 1/4" 28 1/2"

34 1/2"

40 1/2"

24"

30"

36"

34 1/4"

40 1/4"

6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"6 7/8" 7 1/8" 6 3/8" 4 1/4" 4 3/4"

FPB-L24MT-NFPB-L24MT-PFPB-L30MT-NFPB-L30MT-PFPB-L36MT-NFPB-L36MT-P

FPB-L30MT-N

FPB-L36MT-N

FPB-L24MT-P

FPB-L30MT-P

FPB-L36MT-P

MODEL FACTORY ORIFICE BTU OUTPUTCONVERSION KIT PART NO.

LOF30MT-N #36 45,000 OAS-LP49

LOF36MT-N #29 75,000 OAS-LP41

LOF30MSI-N #36 45,000 OAS-LP49

LOF36MSI-N #29 75,000 OAS-LP41

BTU SPECS

PRESSURE GAS TYPE NG GAS TYPE LP

MIN. INLET 5.0" WC 10.5" WC

MAX. INLET 10.5" WC 13.0" WC

NORMAL INLET 7.0" WC 11.0" WC

GAS PRESSURE

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

OAS-LP49 Propane Conversion Kit (Orifice/Air Shutter) for LOF-30 Series. 43,000 Btu

OAS-LP41 Propane Conversion Kit (Orifice/Air Shutter) for LOF-36 Series. 65,000 Btu

LID-LOF30 Linear stainless steel lid with brushed finish for the LOF-30 Series

LID-LOF36 Linear stainless steel lid with brushed finish for the LOF-36 Series

VENT-KIT-6X12 Includes two (2) 6” tall x 12” wide vents with mounting screws

OPTIONAL ACCESSORIES

These products are only sold as Natural Gas. You must purchase an LP Conversion Kit to convert the prodcut to Liquid Propane.

Page 38: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

38

AnF (Assemble and Finish) SPECIFICATIONS

ROUND SERIES

MODELOVERALL DIAMETER

A

OVERALL HEIGHT(TOP INSTALLED)

BMAXIMUM CUT OUT

C

ANF-R42 42 1/4” 18 5/8" 21"

ANF-R48 48 1/4” 18 5/8” 28 7/8"

ANF-R60 60 1/4” 18 5/8” 33 3/8"

A

C

B

AnF ROUND BURNER SYSTEM MATRIX

LINEAR SERIES

MODELLENGTH

A

HEIGHT(TOP INSTALLED)

BDEPTH

C

MAX CUT OUT WIDTH

D

MAX CUT OUT LENGTH

E

ANF-L48 48” 18 1/2” 24" 15 3/4” 44 1/2”

ANF-L66 66” 18 1/2” 24” 6 7/8” 62 1/2”

ANF-L74 74” 18 1/2” 24” 6 7/8” 70 1/2”

ANF-L96 96” 18 1/2” 24” 6 7/8” 89”

B

A

C

E

D

B

A

C

E

D

AnF LINEAR BURNER SYSTEM COMBINATION MATRIXAll single Linear fire pit burner systems fit all Linear AnF’s, and all Linear fire pit burner systems require supports.

FPB-36L + FPB-36LFPB-36L + FPB-30L

FPB-36L + FPB-24LFPB-30L + FPB-30L

FPB-30L + FPB-24LFPB-24L + FPB-24L

ANF-L66 ANF-L74 ANF-L96fits fits fits

16”ROUND

19”ROUND

20”SQUARE

25” ROUND

26”SQUARE

29”ROUND

32”SQUARE

33”ROUND

ANF-R42Does this pan fit this AnF? YES YES YES NO NO NO NO NO

Does it require supports? YES NO NO NO NO NO NO NO

ANF-R48Does this pan fit this AnF? NO YES YES YES YES NO NO NO

Does it require supports? NO YES YES NO NO NO NO NO

ANF-R60Does this pan fit this AnF? NO NO NO YES YES YES YES YES

Does it require supports? NO NO NO YES NO NO NO NO

Page 39: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

39

AnF ROUND PACKAGES

ANFR42-19RTFS-N 42” Round AnF with a 19” Round TFS System (Natural Gas)

ANFR42-19RTFS-P 42” Round AnF with a 19” Round TFS System (Propane)

ANFR42-19RTMS-N 42” Round AnF with a 19” Round TMS System (Natural Gas)

ANFR42-19RMT-N 42” Round AnF with a 19” Round MT System (Natural Gas)

ANFR48-19RTFS-N 48” Round AnF with a 19” Round TFS System (Natural Gas)

ANFR48-19RTFS-P 48” Round AnF with a 19” Round TFS System (Propane)

ANFR48-19RTMS-N 48” Round AnF with a 19” Round TMS System (Natural Gas)

ANFR48-19RMT-N 48” Round AnF with a 19” Round MT System (Natural Gas)

AnF LINEAR PACKAGES

ANFL48-30LTFS-N 48” Linear AnF with a 30” L Series TFS System (Natural Gas)

ANFL48-30LTFS-P 48” Linear AnF with a 30” L Series TFS System (Propane)

ANFL48-30LMT-N 48” Linear AnF with a 30” L Series MT System (Natural Gas)

ANFL48-LOF30MT-N 48” Linear AnF with a 30” Line of Fire MT System (Natural Gas)

AnF ENCLOSURES & FIRE PIT BURNER COMBINATIONS

MODELLENGTH

A

HEIGHT(TOP INSTALLED)

B

MAX CUT OUT LENGTH

C

MAX CUT OUT DEPTH

D

ANF-S48 48” 18 1/2” 40 3/16” 44 1/2”

ANF-S60 60” 18 1/2” 52 3/16” 56 1/2”

SQUARE SERIES

B

A

C

D

B

A

C

D

All Fire Pit Burner Systems fit all square AnF’s, and all Fire Pit Burner Systems require supports

Page 40: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

40

BURNER SPECIFICATIONS

KIT MODEL SINGLE MODELOVERALL WIDTH

AOVERALL HEIGHT

BORIFICE SIZE

NGBTU’S NG

ORIFICE SIZELP

BTU’S LP

DBS-12K DBS-12 12 1/8” 1 7/8" OAS-NG38 42,000 OAS-LP52 33,000

DBS-16K DBS-16 15 7/8” 1 7/8” OAS-NG31 60,000 OAS-LP45 55,000

DBS-22K DBS-22 22 1/16” 1 7/8” OAS-NG22 100,000 OAS-LP35 99,000

DBS-31K DBS-31 30 7/8” 1 7/8” OAS-NG08 160,000 OAS-LP29 150,000

DBS-36K DBS-36 35” 1 7/8” OAS-NG03 183,000 OAS-LP25 182,000

5053-079

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/09/2016

NOTES:1. DESIGNER BURNING SPURS (DBS) ARE INDIVIDUAL SPUR BURNERS FOR INSTALLATION INTO A CUSTOM DESIGNED FIRE PIT. INSTALLATION REQUIRES A METAL PAN (NOT SUPPLIED) TO BE USED UNDERNEATH THE BURNING SPUR PER APPLICATION. DBS BURNERS COME AS AN INDIVIDUAL SPUR SUPPLIED WITH A BURNER ORIFICE (I.E. DBS-12) OR AS A KIT (I.E. DBS-12K) SUPPLIED WITH A BURNER ORIFICE, FLEX CONNECTOR, KEY VALVE, POLISHED CHROME COVER AND A 8" POLISHED CHROME KEY.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

3. ALL INSTALLATIONS SHOULD PROVIDE ACCESS TO VALVE SYSTEMS AS WELL AS GAS CONNECTIONS.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A CUSTOM FIRE PIT WITH THE DBS BURNERS .5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER

REFERENCE NUMBER 5053-079.

BURNING SPUR & BURNING SPUR KITS

BURNING SPUR & BURNING SPUR KITS

SELECT DESIRED MODEL:

DBS-12K

DBS-16K

DBS-12 12 1/8" 1 7/8"

KIT MODELSINGLEMODEL

OVERALL WIDTHA

OVERALL HEIGHTB

TOP VIEW

DBS-22K

DBS-31K

DBS-12KDBS-16KDBS-22KDBS-31K

OAS-NG38

ORIFICE SIZENG

BTU'S NG

DISCLAIMER: BTU LISTINGS ARE BASED ON 7" WC FOR NATURAL GAS (NG) AND 11" WC FOR LIQUID PROPANE (LP) AT THE BURNERORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU'S. AS A RESULT YOUR BTU'S MAY VARY SLIGHTLY FROMTHE LISTED BTU SPECIFICATIONS.

DBS-16DBS-22DBS-31

15 7/8" OAS-NG3122 1/16" OAS-NG2230 7/8" OAS-NG08

DBS-36K

ORIFICE SIZELP

BTU'S LP

42,000 OAS-LP52 33,00060,000 OAS-LP45 55,000

100,000 OAS-LP35 99,000160,000 OAS-LP29 150,000

DBS-36K DBS-36 35" OAS-NG03 183,000 OAS-LP25 182,000

DBS-12

DBS-16

DBS-22

DBS-31

DBS-36

1 7/8"1 7/8"1 7/8"1 7/8"

A

B

SIDE VIEW

BURNING SPUR

DISCLAIMER: BTU LISTINGS ARE BASED ON 7.0” WC FOR NATURAL GAS (NG) AND 11.0” WC FOR LIQUID PROPANE (LP) AT THE BURNER ORIFICE. FLEX LINE SIZE AND PROPER GAS PIPE SIZING WILL ALSO AFFECT BTU’S. AS A

RESULT YOUR BTU’S MAY VARY SLIGHTLY FROM THE LISTED BTU SPECIFICATIONS.

LIQUID PROPANE ORIFICE NATURAL GAS ORIFICE

Page 41: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

41

FLEXFRAME SPECIFICATIONS

MODELS

FLEXFRAME-SS Constructed of 16 Gauge 304 Stainless Steel. Engineered to protect against outdoor elements including salt water environments - two (2) 44” pieces per package.

FEATURESFLEXFRAME-PC Constructed of Zinc Epoxy Coated 16 Gauge

Galvanized Steel. Engineered to protect against outdoor elements - two (2) 44” pieces per package

The Flexframe allows you to fill the gap between the inside opening and the burner pans or disc

The flexframe can be bent or cut to fit any shape (square, linear or round) fire pit.

Allows you to remove the burner system without removing any pavers

Example of the Flexframe in a round fire pit

Example of the Flexframe in a square/linear fire pit

Page 42: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

42

PAVER KIT CONTROL PANELS SPECIFICATIONS

REV. 12-31-14 Page 1 of 7MT PAVER KITS

DESCRIPTION: The Paver Kit face plate bracket (control panel) is designed to install in conjunction with a typical Patio Block fire pit kit (purchased separately). It installs underneath the fire pit pan/disc in place of one patio block. The control panel itself provides a convenient location to house the gas valve and Piezo ignition (if applicable) then is easily removed for servicing.

This installation instruction covers two (2) separate kits: 1) PAVER-KIT-MT and 2) PAVER-KIT-MT-MSI.

DIMENSIONS: The Paver Kit bracket and extension will fit an opening with a maximum of 10.500” wide x 3.500” tall. Without the Bracket Extension plate the maximum width is 8.00” wide. The holes in the Extension Bracket are spaced every .500”.

10.500” Max.

8.00” Min.

3.500”

Fig 3. Paver Kit Control Panel Dimensions

Fig. 1 Paver kit with fire pit pan. Fig. 2. Paver kit with fire pit flat disc.

TOOLS NEEDED: (1) Drill/driver, Gas Rated Teflon Tape or Compound, 5/16” Hex head driver, (1) 3/16” Concrete Drill Bit, (2) Adjustable Wrenches, Assorted Open-end Wrenches

Table of Contents

Description Page 1

General Instructions Page 1 - 2

PAVER-KIT-MT Page 2 - 3

PAVER-KIT-MT-MSI Page 3 - 5

Warranty Page 6

Replacement Parts Page 7

PRECAUTION: If you are installing the MSI (Manual Spark Ignition) ensure the PAVER-KIT-MT-MSI control panel is with-in 40-inches of the 2-probe Piezo ignitor. This will allow enough “play” in the wires to make your connections. See Fig. 16 on page 5.

Round Fire Pit Pan Round Flat Fire Pit Disc

PAVER KIT MOUNTING BRACKETAll paver kit control panels come with the same paver mounting bracket.

PAVER KIT MT

REV. 12-31-14 Page 2 of 7 MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONSModels include: PAVER-KIT-MT & PAVER-KIT-MT-MSI

REV. 12-31-14 Page 3 of 7MT PAVER KITS

Paver BlockPaver Block

Fig. 7 Installing MT valve into control panel.

STEP 2: Once the 90° elbows are installed into the manual key valve then install the MT key valve bracket into Paver Kit control panel as shown in Fig. 7.

STEP 3: Secure the key valve bracket into place using the four black thread cutting screws. See Fig. 8.

STEP 4: Install the flex connector from the burner to either side of the gas valve and connect gas supply to the other side of the gas valve. Conduct a trial burn test by temporarily connecting the fire pit pan and burner and check for any gas leaks before completing the installation. See fire pit manual for proper connections.

See page 6 for lighting instructions.

STEP 5: After burn test is complete, finish the patio paver blocks installation.

PAVER KIT-MT-MSI INSTALLATION

CAUTION: Turn OFF gas supply before beginning installation. If the fire pit is already installed, remove all media before beginning installation.

Step 1: Prepare the fire pit pan or disc by first removing the two screws from the 1” x 2” metal cover plate exposing the rectangular hole then align the burner leg as shown in Fig. 9. The inside edge of the burner leg should be approximately 3/4-inch away from the inside edge of rectangular hole.

Step 2: Remove the two stainless steel screws and nuts from the probe assembly but leave it assembled. Carefully slide the orange wire from the top of the pan through rectangular hole in the fire pit pan resting over the burner leg and install the screws into the existing holes of the cover plate. See Fig. 10.

Cover Plate

Fig. 9 Removing cover plate from pan.

Fig. 8 Close up view securing MT valve bracket to control panel.

REV. 12-31-14 Page 3 of 7MT PAVER KITS

Paver BlockPaver Block

Fig. 7 Installing MT valve into control panel.

STEP 2: Once the 90° elbows are installed into the manual key valve then install the MT key valve bracket into Paver Kit control panel as shown in Fig. 7.

STEP 3: Secure the key valve bracket into place using the four black thread cutting screws. See Fig. 8.

STEP 4: Install the flex connector from the burner to either side of the gas valve and connect gas supply to the other side of the gas valve. Conduct a trial burn test by temporarily connecting the fire pit pan and burner and check for any gas leaks before completing the installation. See fire pit manual for proper connections.

See page 6 for lighting instructions.

STEP 5: After burn test is complete, finish the patio paver blocks installation.

PAVER KIT-MT-MSI INSTALLATION

CAUTION: Turn OFF gas supply before beginning installation. If the fire pit is already installed, remove all media before beginning installation.

Step 1: Prepare the fire pit pan or disc by first removing the two screws from the 1” x 2” metal cover plate exposing the rectangular hole then align the burner leg as shown in Fig. 9. The inside edge of the burner leg should be approximately 3/4-inch away from the inside edge of rectangular hole.

Step 2: Remove the two stainless steel screws and nuts from the probe assembly but leave it assembled. Carefully slide the orange wire from the top of the pan through rectangular hole in the fire pit pan resting over the burner leg and install the screws into the existing holes of the cover plate. See Fig. 10.

Cover Plate

Fig. 9 Removing cover plate from pan.

Fig. 8 Close up view securing MT valve bracket to control panel.

PAVER KIT TMSModels include: PAVER-KIT-TMS & PAVER-KIT-TMS-MSI

REV. 12-31-14 Page 2 of 9TMS PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws.

Fig. 4 Securing the control panel into the paver block.

Fig. 5 Control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

GENERAL INSTRUCTIONS

3/8” NPT Close Nipple

3/8” NPT Black Iron 90° Elbow

(U1-8C-S)1/2" OD Flare x

3/8" MIP

Piezo Ignitor Mounting Hole

Gas Inlet

Fig. 6 TMS valve fitting orientation.

With the paver kit face plate bracket (control panel) installed you are now ready to install the TMS gas valve.

STEP 1: Prepare the 3/8” close nipple and 1/2” OD Flare x 3/8” brass fittings by installing gas rated Teflon tape or compound to the male threads and install them into the TMS valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. The TMS valve comes with a 1/2” OD Flare x 3/8” brass fitting. Ensure you use this fitting to complete the installation. See figure 6 for proper orientation.

NOTE: Ensure to attach the flex connector from gas supply to the inlet side of the gas valve. Hard piping may also be installed in place of the flared connector.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

PAVER KIT-TMS INSTRUCTIONS

REV. 12-31-14 Page 3 of 9TMS PAVER KITS

STEP 2: Once the fittings are installed into the TMS valve then install the valve and bracket into Paver Kit control panel as shown in figure 7.

STEP 3: Secure the TMS valve bracket into place using the four black thread cutting screws. See Fig. 8.

STEP 4: Install the flex connector from the burner to outlet side of the gas valve and connect gas supply to the inlet side of the gas valve. Conduct a trial burn test and check for any gas leaks before completing the installation.

See page 7 for lighting instructions.

STEP 5: After burn test is complete, finish the patio paver block installation.

Paver BlockPaver Block

Fig. 7 Installing TMS valve into control panel.

PAVER KIT-MT-MSI INSTALLATION

Fig. 9 Removing screen cover from ignitor hood.

CAUTION: If the fire pit is installed then turn OFF main gas supply and remove all media prior to installation of MSI Kit.

Step 1: Prepare the fire pit pan by first removing the screen cover hood from the ignitor hood. See Fig.9.

Fig. 8 Close up view securing TMS valve bracket to control panel.

REV. 12-31-14 Page 3 of 9TMS PAVER KITS

STEP 2: Once the fittings are installed into the TMS valve then install the valve and bracket into Paver Kit control panel as shown in figure 7.

STEP 3: Secure the TMS valve bracket into place using the four black thread cutting screws. See Fig. 8.

STEP 4: Install the flex connector from the burner to outlet side of the gas valve and connect gas supply to the inlet side of the gas valve. Conduct a trial burn test and check for any gas leaks before completing the installation.

See page 7 for lighting instructions.

STEP 5: After burn test is complete, finish the patio paver block installation.

Paver BlockPaver Block

Fig. 7 Installing TMS valve into control panel.

PAVER KIT-MT-MSI INSTALLATION

Fig. 9 Removing screen cover from ignitor hood.

CAUTION: If the fire pit is installed then turn OFF main gas supply and remove all media prior to installation of MSI Kit.

Step 1: Prepare the fire pit pan by first removing the screen cover hood from the ignitor hood. See Fig.9.

Fig. 8 Close up view securing TMS valve bracket to control panel.

Front View Top View Finished Front View

Top View

Top View Angle View

Top View

Top View

Angle View

REV. 12-31-14 Page 2 of 7MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONS

REV. 12-31-14 Page 2 of 7MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONS

REV. 12-31-14 Page 2 of 7MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONS

REV. 12-31-14 Page 2 of 7MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONS

REV. 12-31-14 Page 2 of 7MT PAVER KITS

STEP 1: Determine the best location to install the paver kit control panel per your installation.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the control panel can be adjusted to fit various openings. NOTE: When measuring it is recommended but not required to recess the control panel to protect the valve components from weather.

STEP 3: After you have determined the location and measured the width to install the Paver Kit control panel mark the inside of the control panel as shown in figure 4.

NOTE: This manual covers two specific models. This section will provide a general installation of the Paver Kit control panel. See Table of Contents for specific instruction for your application.

NOTE: Follow the directions from your paver block fire pit kit to build the actual fire pit. Depending on your fire pit pan (flat disc or pan) ensure the Paver Kit control panel is installed underneath the pan or disc.

Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation.

STEP: 4 Drill the two holes with a 3/16” concrete drill bit and secure the paver kit control panel with concrete screws. Figure 5 shows front view.

Fig. 4 Top view of control panel securing into the paver block.

Fig. 5 Front view of control panel installed, ready for valve bracket.

Paver BlockPaver Block

Place control panel into position, mark the two holes, remove the control panel and

drill holes with 3/16” concrete drill bit.

With the paver kit face plate bracket (control panel) installed you are now ready to install the manual gas valve.

STEP 1: Prepare the two ½” flare x ½” MIP 90° brass elbows by installing gas rated Teflon tape or compound to the male threads and install them into the manual key valve that came with your fire pit. Ensure the fittings are tight to prevent any gas leaks. See figure 6 for proper orientation.

NOTE: The manual key valve has no particular inlet or outlet designation therefore the inlet gas can be connected to any of the flared ends.

CAUTION: Do not use any Teflon tape or compound on the flared ends of the fittings.

½” Flare x ½” MIP 90° Brass Elbow

Manual Key Valve

½” Flare x ½” MIP 90° Brass

Elbow

Key Valve Flange

Piezo Ignitor Mounting Hole

Fig. 6 Manual key valve elbow orientation.

GENERAL INSTRUCTIONS

PAVER KIT-MT INSTRUCTIONS

Page 43: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

43

MSI KITS FOR PAVER CONTROL PANELS

MT KEY VALVE

REV. 12-31-14 Page 6 of 9TMS PAVER KITS

Fig. 16 Removing plastic plug from mounting plate.

Fig. 18 Installing Piezo module into mounting plate.

3/8” NPT Close Nipple

3/8” NPT Black Iron 90° Elbow

(U1-8C-S)1/2" OD Flare x

3/8" MIP

Piezo Ignitor Mounting Hole

Gas Inlet

Fig. 19 Attaching Piezo ignition wires.

Step 8: Remove the black plastic plug from the valve mounting plate for preparation of installing the Piezoignition module. See Fig. 16.

Step 9: The Piezo module mounts directly to the TMS valve bracket. Install the Piezo module using the smaller hole with the two notches and slide module into the place until it stops. Using the plastic nut thread it onto the Piezo module to secure into place. Be careful not to turn the nut too tight and crack the plastic. Install the AAA battery as shown and thread the red button cap on the remaining threads of the module. See Fig. 17.

Step 10: Connect the 3/16” end of the PIEZO23WH extension wire and 3/16” end of the PIEZO48WH wire into the back side of the spark ignitor module. See Fig. 19 detail.

Step 11: Attach the 1/4” end of extension wire (PIEZO23WH) to the orange ignitor wire and attach the 1/4” wire end (PIEZO48WH) wire to ground tab under the burner pan. See figure drawings 14, 19 and 20 for reference.

Step 12: Reconnect the thermocouple lead to the gas valve. Install it finger tight plus a quarter turn with a wrench.

+ -AAA

Plastic Nut

Red Button Cap

Mounting Plate

Fig. 17 Installing battery into Piezo module.

PIEZO48WH

PIEZO23WH

Inlet

Thermocouple Lead

Outlet

PAVER-KIT-MT-MSI PAVER-KIT-TMS-MSI

REV. 12-31-14 Page 5 of 7MT PAVER KITS

Step 5: Install the ignition hood over top of the ignition probe assembly into the existing pre-punched holes of the burner pan by using the five #10 - 24 x ½” provided screws. See Fig. 14.

Step 6: Ensure the Paver kit control panel is within 40-inches of the 2-probe Piezo ignitor. This will allow enough “play” in the wires to make your connections. If not you may have to rotate the pan or disc to make proper connections.

Step 7: Connect the 3/16” end of the PIEZO23WH extension wire and 3/16” end of the PIEZO48WH wire into the back side of the spark ignitor module. See Fig. 15 detail.

Step 8: Attach the 1/4” end of extension wire (PIEZO23WH) to the orange ignitor wire and attach the 1/4” wire end (PIEZO48WH) wire to ground tab under the burner pan.See Fig. 16.

Step 9: Test the ignitor by pushing and holding the red button to ensure the 2-probe ignitor is sparking inside the ignition box in the burner pan. The spark should be located directly over top of the burner port hole for proper ignition of the gas as previously discussed. Spacing between the probes should be approximately 1/8” for proper spark. See Fig. 12 on page 4 if necessary.

Step 10: Install the ignition hood screen mesh and ensure no media lays on the screen mesh area. See Fig. 17. Install the lava rock/media material according to fire pit install manual and turn the main gas supply back ON. Installation is now complete.

Fig. 15 Wiring into the Piezo module.

Manual Key Valve

Gas Supply

Fire Pit PanProbe Assembly

Orange Wire

Piezo ModulePIEZO23WH

PIEZO48WH

ON

OFF

Lava RockLava Rock

Lava Rock

Ignition Hood

Ignition Hood Screen

Spur Burner Leg

Ignition Hood

Ignitor Probes

Rainshield

Fig. 14 Installing ignition hood.

Fig. 16 Wiring diagram Fig. 17 Installing screen mesh cover on ignitor hood.

PAVER VENT KITS

REV. 9-10-15 Page 2Paver Vents 4-6

DESCRIPTION: These vents are designed to be used with most paver block fire pit enclosures and can be installed as a universal vent for other applications such as grill islands, fire table or bars. The vents provided with this kit provide a minimum of 18-square inches per vent.

Many fire pits require a minimum of 18 square inches of cross ventilation (see Fig.1). This cross ventilation provides sev-eral things: 1. It allows fresh air to keep the enclosure dry and protect any electronic components to ensure they operate and function as designed. 2: It provides an outlet for possible gas leaks and can prevent any potential delayed ignitions. 3. It assist in keeping the enclosure cooler due to radiant heat that can occur during operation.

In some cases the extension bracket may be not needed because the vent can be recessed inside the blocks to help camouflage them. Two vents per fire pit are required on each side of enclosure to ensure cross ventilation.

ON

OFF

AT ON

POSITIO

N

SLIGH

T PUSH

TO

TURN

OFF

FULL PU

SH TO

LIGH

T

Cross Flow Ventilation

8”

3.5”

7”

3.12”

8”

5.5”

7”

5.12”

Fig. 2 PAVER-VENT - 4

Fig. 3 PAVER-VENT- 6

Fig. 1 Cross ventilation example

REV. 9-10-15 Page 2Paver Vents 4-6

DESCRIPTION: These vents are designed to be used with most paver block fire pit enclosures and can be installed as a universal vent for other applications such as grill islands, fire table or bars. The vents provided with this kit provide a minimum of 18-square inches per vent.

Many fire pits require a minimum of 18 square inches of cross ventilation (see Fig.1). This cross ventilation provides sev-eral things: 1. It allows fresh air to keep the enclosure dry and protect any electronic components to ensure they operate and function as designed. 2: It provides an outlet for possible gas leaks and can prevent any potential delayed ignitions. 3. It assist in keeping the enclosure cooler due to radiant heat that can occur during operation.

In some cases the extension bracket may be not needed because the vent can be recessed inside the blocks to help camouflage them. Two vents per fire pit are required on each side of enclosure to ensure cross ventilation.

ON

OFF

AT ON

POSITIO

N

SLIGH

T PUSH

TO

TURN

OFF

FULL PU

SH TO

LIGH

T

Cross Flow Ventilation

8”

3.5”

7”

3.12”

8”

5.5”

7”

5.12”

Fig. 2 PAVER-VENT - 4

Fig. 3 PAVER-VENT- 6

Fig. 1 Cross ventilation example

PAVER-VENT-4 PAVER-VENT-6

REV. 9-10-15 Page 4

PRECAUTION: The vent bracket is designed to be mounted to a paver block by drilling two holes and securing it into place with two concrete screws(provided). If you desire to place the vent in the first row of patio blocks you may need to install a block below grade level to secure the vent bracket into place.

At the same time, depending on how your are laying your paver blocks you may need to incorporate a lintel (not included) to lay across the top of the paver vent to support your next row of blocks. The reason for this is that the vent may support the front edge of a block but the back edge could easily fall without some type of additional support. We suggest using a rigid 3" x 12" metal plate (part # PAVER-VENT-LINTEL) to order one if needed.

STEP 1: Determine the best location to install the paver vent in your enclosure.

STEP 2: Remove one block from your fire pit enclosure then measure the width between the opening. Depending on the block width the vent bracket can be adjusted to fit various openings. NOTE: When installing it is recommended (but not required) to recess the vent bracket an inch or two to help camouflage the vent and keep it in a lower area of the enclosure. Vent can also be painted to match block if desired.

The bracket extension can be used to extend the vent bracket from 8-inches wide up to 10-inches wide if necessary. The holes in the bracket extension allow for 1/2" increments for width adjustment. Figure 5 shows the extension in the properly oriented position. If the extension bracket is installed and your are using any of the holes numbered 3 & 4, the perforated area should be bent and broken off (removed) to ensure you are not covering the vent bracket opening.

Paver BlockPaver Block

Top View of Vent Installed

Place the vent bracket into position, mark the two holes, remove vent bracket and drill two

holes with a 3/16” concrete drill bit.

Fig. 4 Top view of vent installed

Fig. 5 Extension bracket installed

STEP 3: After you have determined the location and measured the width, install the vent kit bracket and mark the two holes on the inside area of the bracket as shown in figure 3.

STEP 4: Drill the two holes with a 3/16” concrete drill bit and secure the paver vent bracket with the two concrete screws. Figure 5 shows front view.

Proper Orientation

1 2 3 4

1 2 3 4

Paver Vents 4-6

Top View Top View

Angle View

Front View

Front View

Page 44: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

44

MEDIA INSTALL GUIDE

LAVA ROCK ONLYWhen using only lava rock, you only need to use as much lava rock in order to cover the burner. Do not over-fill. Just use enough to hide the burner from view.

LAVA ROCK

LAVA ROCK & GLASSIn order to use glass, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your glass and lay it on top of the lava rock and burner. The glass should only be 3/4” to 1”thick, or just enough to cover the burner.

LAVA ROCK

GLASS

LAVA ROCK & LAVA STONE

LAVA ROCK

LAVA STONEIn order to use lava stones, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your lava stones and lay it on top of the lava rock and burner. The lava stones should only be one layer thick, just enough to cover the burner.

LAVA ROCK & LAVA BOULDER

LAVA ROCK

LAVA BOULDERIn order to use lava boulders, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your lava boulders and lay it on top of the lava rock and burner. Lava boulders are 6” to 12” in diameter, there is enough room between them that gas can flow properly. You can use as many as you like.

LAVA ROCK & LOG SET

LAVA ROCK

LOG SETIn order to use a log set, we recommend that you lay down a bottom layer of lava rock. Fill the pan with lava rock until it is level with the top of the burner. Then take your log set and lay it on top of the lava rock and burner.

Page 45: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

45

SQUARE FIRE PITS

LINEAR FIRE PITS

INSIDE DIAMETER LAVA ROCK ONLY LAVA ROCK AS A BASEGLASS ON TOP OF

LAVA ROCKLAVA STONE ON

TOP OF LAVA ROCKLAVA BOULDERS ON TOP

OF LAVA ROCK16” 10 lbs 5 lbs 10 lbs 10 lbs 1/4 box

19” 15 lbs 10 lbs 20 lbs 15 lbs 1/2 box

25” 20 lbs 15 lbs 30 lbs 20 lbs 3/4 box

29” 25 lbs 20 lbs 40 lbs 25 lbs 1 box

33” 30 lbs 25 lbs 50 lbs 30 lbs 1 box

34” 30 lbs 25 lbs 60 lbs 30 lbs 1 box

44” 50 lbs 35 lbs 70 lbs 50 lbs 2 - 3 boxes

ROUND FIRE PITS

HOW MUCH MEDIA TO USE

INSIDE DIAMETER LAVA ROCK ONLY LAVA ROCK AS A BASEGLASS ON TOP OF

LAVA ROCKLAVA STONE ON

TOP OF LAVA ROCKLAVA BOULDERS ON TOP

OF LAVA ROCK20” 15 lbs 10 lbs 20 lbs 15 lbs 1/2 box

26” 20 lbs 15 lbs 30 lbs 20 lbs 3/4 box

32” 30 lbs 25 lbs 50 lbs 30 lbs 1 box

38” 35 lbs 30 lbs 60 lbs 35 lbs 1 1/4 box

INSIDE DIAMETER LAVA ROCK ONLY GLASS ONLY LAVA STONE ONLY

24” 10 lbs 10 lbs 6 lbs

30” 10 lbs 13 lbs 10 lbs

36” 15 lbs 15 lbs 12 lbs

48” 16 lbs 20 lbs 16 lbs

54” 18 lbs 23 lbs 18 lbs

60” 20 lbs 26 lbs 20 lbs

66” 22 lbs 28 lbs 22 lbs

72” 24 lbs 30 lbs 24 lbs

Page 46: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

46

CONTROLS

AF4000ADP24(80)110 volts AC adapter, coverts to 7.5 DC volts for TFS systems. Requires a weather resistant enclosure.

WIRING DIAGRAM

OUTPILOT ADJ

INMAIN

PILOT

Battery Pack

Black (Ground)

GreenWhite

2-Brown

White

Black (-)

Red (+)

Black (4-Pin Connector)

Red

Red

Blac

kBl

ack

Learn AUX

Rem

ote/

OFF

VCS-5000MODTCModule

IS

(Ignitor)(Sensor)(Thermocouple Ground Wire)

Ignitor Assembly

Copper

Orange

Tan

POWER

Orange

Latching Solenoid-DC Motor Drive

Low Rate Set Screw

The AF4000ADP24(80) plugs into the POWER plugs on the module, which is inside the metal box underneath the Fire Pit Burner System. Once the adaptor is plugged into the module, you must plug it in to a GFCI outlet that is installed in a double-outlet NEMA 3R Enclosure (not provided).

Please note that this adapter is only 24” long. Do not try to run this adaptor outside of the enclosure. An electrical line will need to be ran into the enclosure and secured using a double-outlet NEMA 3R Enclosure (not provided). Please review your local codes.

Please note that the battery pack still needs to be attached to the system for normal operation.

This is representative of the wires leaving the box in order to be plugged into the recepticle, which is outside the box but still inside the enclosure.

24”

1.1”

2.6”1.9”

Front View Side View

Page 47: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

47

AF4000HAT

SPA

SPA WATERFALL

MUSIC

JETS

POOL

CLEANER

FOUNTAIN

GAS APPLIANCE

MENU HEAT LIGHTS DISPLAY

HOME AUTOMATION SYSTEMTFS FIRE PIT SYSTEM HAT TRANSMITTER

This is Firegear’s Home/Pool Automation Transmitter. It allows you to operate

your Firegear TFS product from the same controller you‘re used to using your

pool system. It’s important to note that even though you are using the HAT, you

can still use your original remote that came with your TFS unit.

This is a wireless signal. The transmitter must be within 20’ of the control module, which is located underneath the fire pit. If the AF-4000HAT is installed outside, it much be installed in a NEMA 3R Enclosure (not provided) or weather resistant enclosure.

The AF4000HAT comes with a wall plate making it easy to mount on any wall.

Maximum 100-feet of 18-gauge (or larger) wire that is suitable for outdoors

WIRING DIAGRAM

Page 48: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

48

LIDS

5053-098

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.

2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-098.

ROUND LIDS

BURNER LIDS

SELECT DESIRED MODEL:

LID-16R

LID-19R

19" 5/8"

MODELOUTSIDE DIM.

ALID HEIGHT

B

TOP VIEW

LID-16RLID-19R

LID HEIGHT WITHHANDLE

22 3/8"2"

SIDE VIEW

A

B

LID-25R 28 3/8"LID-29R 32 1/2"LID-33R 36 1/2"

5/8" 2"5/8" 2"5/8" 2"5/8" 2"

LID-25R

LID-29R

LID-33R

MODELOUTSIDE DIM.

ALID HEIGHT

BLID HEIGHT

WITH HANDLE

LID-16R 19” 5/8” 2"

LID-19R 22 3/8” 5/8” 2”

LID-25R 28 3/8” 5/8” 2”

LID-29R 32 1/2” 5/8” 2”

LID-33R 36 1/2” 5/8” 2”

ROUND

SIDE VIEW

B

MODELOUTSIDE DIM.

ALID HEIGHT

BLID HEIGHT

WITH HANDLE

LID-20S 22 1/4” 1 1/4” 2"

LID-26S 28 1/4” 1 1/4” 2”

LID-32S 34 1/4” 1 1/4” 2”

LID-38S 40 1/4” 1 1/4” 2”

SQUARE

5053-099

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-099.

SQUARE LIDS

BURNER LIDS

SELECT DESIRED MODEL:

LID-20S

LID-26S

22 1/4" 1 1/4"

MODELOUTSIDE DIM.

ALID HEIGHT

B

TOP VIEW

LID-20SLID-26S

22 1/4"

LID WIDTHC

LID HEIGHT WITHHANDLE

28 1/4"2 5/8"

1 1/4"

SIDE VIEW

28 1/4" 2 5/8"

C

A

B

LID-32S 34 1/4" 1 1/4" 34 1/4" 2 5/8"LID-38S 40 1/4" 1 1/4" 40 1/4" 2 5/8"

LID-32S

LID-38S

5053-099

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.

3. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.4. DRAWINGS NOT TO SCALE.5. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.6. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

7. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-099.

SQUARE LIDS

BURNER LIDS

SELECT DESIRED MODEL:

LID-20S

LID-26S

22 1/4" 1 1/4"

MODELOUTSIDE DIM.

ALID HEIGHT

B

TOP VIEW

LID-20SLID-26S

22 1/4"

LID WIDTHC

LID HEIGHT WITHHANDLE

28 1/4"2 5/8"

1 1/4"

SIDE VIEW

28 1/4" 2 5/8"

C

A

B

LID-32S 34 1/4" 1 1/4" 34 1/4" 2 5/8"LID-38S 40 1/4" 1 1/4" 40 1/4" 2 5/8"

LID-32S

LID-38S

MODELLENGTH

ALID HEIGHT

BLID WIDTH

C FITS THESE MODELS

LID-24L 29 3/4” 2 5/8” 8 1/4” FPB-L24

LID-30L 35 3/4” 2 5/8” 8 1/4” FPB-L30

LID-36L 41 3/4” 2 5/8” 8 1/4” FPB-L36

LID-60L 53 3/4” 2 5/8” 8 1/4” (2)FPB-L24 End to End

LID-68L 69 3/4” 2 5/8” 8 1/4” (2)FPB-L30 End to End

LID-84L 77 3/4” 2 5/8” 8 1/4” (2)FPB-L36 End to End

LID-LOF30 32 3/8” 2 5/8” 8 1/4” LOF30 Series

LID-LOF36 38 3/8” 2 5/8” 8 1/4” LOF 36 Series

LINEAR

5053-097

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. LINEAR LIDS LISTED ABOVE WILL ONLY FIT LOF30 AND LOF36 MODELS AT THE CURRENT TIME.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-097.

LINEAR LIDS

BURNER LIDS

SELECT DESIRED MODEL:

LID-30L

LID-36L

32 3/8" 1 1/4"

MODELOUTSIDE DIM.

ALID HEIGHT

B

TOP VIEW

LID-30LLID-36L

8 1/4"

LID WIDTHC

LID HEIGHT WITHHANDLE

38 3/8"2 5/8"

1 1/4"

SIDE VIEW

8 1/4" 2 5/8"

C

B

A

5053-097

FIREGEAR OUTDOORS9230 CONSERVATION WAY

FORT WAYNE, IN 46809TOLL FREE: 1-888-672-8929

FAX: (888) 672-8024www.firegearoutdoors.com

CADdetails.comPROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 05/26/2016

NOTES:1. LIDS COME WITH A HANDLE THAT MUST BE ATTACHED FOR USE.2. LINEAR LIDS LISTED ABOVE WILL ONLY FIT LOF30 AND LOF36 MODELS AT THE CURRENT TIME.

3. ALL FIRE PITS REQUIRE 18-SQUARE INCHES OF CROSS FLOW VENTILATION PER SIDE OF ENCLOSURE.4. ALWAYS ADHERE TO YOUR STATE AND LOCAL CODES WHEN INSTALLING A FIRE PIT.5. DRAWINGS NOT TO SCALE.6. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES

ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.7. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT

MANUFACTURER TO BE CONSIDERED ACCURATE.

8. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTERREFERENCE NUMBER 5053-097.

LINEAR LIDS

BURNER LIDS

SELECT DESIRED MODEL:

LID-30L

LID-36L

32 3/8" 1 1/4"

MODELOUTSIDE DIM.

ALID HEIGHT

B

TOP VIEW

LID-30LLID-36L

8 1/4"

LID WIDTHC

LID HEIGHT WITHHANDLE

38 3/8"2 5/8"

1 1/4"

SIDE VIEW

8 1/4" 2 5/8"

C

B

A

SIDE VIEW

B

SIDE VIEW

B

Page 49: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

49

WINDSHIELDS

MODEL DIAMETER FITS THESE PAN SIZES

GWS-22R 22” FPB16 - FPB19 (round)

ROUND

MODEL LENGTH WIDTH HEIGHT FITS THESE PAN SIZES

GWS-3030 30” 30” 7 1/2” FPB-20S (Square)

GWS-3838 38” 38” 7 1/2” FPB-26S, FPB-32S (Square)

GWS-4242 42” 42” 7 1/2” FPB-38S (Square)

GWS-3812 / GWS-3810 38”/38” 12”/10” 7 1/2” FPB-24L,LOF-30

GWS-4312 / GWS-4410 43”/44” 12”/10” 7 1/2” FPB-30L, FPB-36L, LOF-36

GWS-6010 60” 10” 7 1/2” FPB-24L + FPB-24L or FPB-30L + FPB-24L

GWS-8512 / GWS-8410 85”/84” 12”/10” 7 1/2” FPB-36L + FPB-36L or FPB-36L + FPB-30L

SQUARE / RECTANGULAR

Page 50: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

50

VENT KIT

VENT-KIT-6X12

DESCRIPTION: These vents are designed to be used with Ready to Fit (RTF) enclosures as well as universal vent for many other types of fire pit enclosures. Figure 1 shows the actual dimensions of each vent.

Item # Part Number Description Qty.1 VENT- 6x12 6” x 12” Vent 22 SCREW1024PANBL 1.25” Phillips black pan head screw 123 ST3-113-1020 10x24 Stainless steel nut 124 WASHER10SS #10 Stainless steel flat washer 12

11.380”

5.750” 3.500”TYP.

.500” TYP.

12

3 4

Fig. 1 Vent dimensions.

Replacement Parts

Table 1: Part Identification

Vent Kit - 6x12 2-8-16 Page 1

These vents are designed to be used with Assemble-n-Finish (AnF) enclosures as well as a universal vent for many other types of fire pit enclosures.

9.750”

3.750”

Cut Out Detail

Install the vents on opposite sides of the enclosure to ensure cross flow ventilation. Cross flow ventilation is necessary to provide free flowing air to assist in keeping the enclosure dry and cool during operation of a fire pit.

Cut an rectangular opening 9.75” x 3.75” into on opposite sides of the enclosure. Center the vent over the cut out area ensuring the vent slots are clear of any obstruction. Mark the holes with a pencil or marker. Drill six ¼” clearance holes, place the vent centered over the opening, insert a screw into the vent and enclosure at the same time and secure with washer and nut on the inside. Repeat the process until all six screws are securing each vent into place on both sides of the enclosure.

Fig. 2 Cutting hole in enclosure and installing vent.

FOR TECHNICAL SERVICE, CALL:

Firegear Outdoors9230 Conservation WayFort Wayne, IN 46809

For Sales: (888) 672-8929

WEB SITE: www.firegearoutdoors.com

(855) 498-8324

Vent Kit - 6x12 2-8-16 Page 2

CROSS VENTILATIONFire pits are subjected to many outdoor elements such as rain, snow, wind, heat or cold. A minimum of 18 square inches of cross ventilation (2 sides) is required to keep the components in good working order. Use the figure below as a guide to assist you to incorperate proper ventilation.

When using LP gas, ventilation should be located near the base of the structure.

AIR FL

OW

The vents should be placed in the middle of the enclosure, and on opposite sides

AIR FLOW

Page 51: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

51

Length of Pipe in Feet 1/2” 3/4” 1” 1 - 1/4” 1 - 1/2” 2” 2 - 2 1/2” 3” 4”

10 275 567 1071 2205 3307 6221 10140 17990 35710

20 189 393 732 1496 2299 4331 7046 12510 25520

30 152 315 590 1212 1858 3465 5695 10110 20620

40 129 267 504 1039 1559 2992 4778 8481 17300

50 114 237 448 913 1417 2646 4343 7708 15730

60 103 217 409 834 1275 2394 3908 6936 14150

70 89 185 346 724 1086 2047 3329 5908 12050

80 78 162 307 630 976 1811 2991 5309 10830

90 69 146 275 567 866 1606 2654 4711 9613

100 63 132 252 511 787 1496 2412 4281 8736

125 54 112 209 439 665 1282 2083 3618 7382

150 48 100 185 390 590 1138 1808 3210 6549

175 43 90 168 353 534 1030 1637 2905 5927

200 40 83 155 325 491 947 1505 2671 5450

300 37 77 144 303 458 887 1404 2492 5084

NATURAL GAS : PIPE SIZING CHART

• Natural Gas (NG) flow is given

in thousands of BTU/hr. One

cubic foot of LP gas - 1000 BTU

• Nominal pressure at the burner

for Natural Gas is 3.5” of water

column. (Typical machine

supply 5”-7”)

• Pipe length must include

additional length for all fittings.

Add approximately 5 feet of

pipe per fitting.

• Natural Gas Example: A

machine with a burner that

requires 440,000 BTU would

need a 1 -1/4” pipe for a 20”

long run.

LIQUID PROPANE : PIPE SIZING CHART

NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure. This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel Gas Code - current edition) for more details.

To determine how long a gas appliance will operate on one tank of gas first determined the total Btu’s of the propane tank. Divide that number by the total Btu’s of your appliance. This will provide to the approximate total time your gas appliance will operate on the tank of gas.

Example: I have a LP gas fire pit rated at 105,000 Btu’s and I am considering using a 20lb. Propane tank to operate it. If you take 430,000 Btu’s (total Btu’s of a 20lb. tank) divided by 105,000 Btu’s the total operating time will be approximate 4.09 hours.

PROPANE TANK BTU’S

Length of Pipe in Feet 1/2” 3/4” 1” 1 - 1/4” 1 - 1/2” 2” 2 - 2 1/2” 3” 4”

10 108 230 387 793 1237 2259 3640 6434 -

20 75 160 280 569 877 1610 2613 5236 9521

30 61 129 224 471 719 1335 2165 4107 7859

40 52 110 196 401 635 1143 1867 3258 6795

50 46 98 177 364 560 1041 1680 2936 6142

60 42 89 159 336 513 957 1559 2684 5647

70 38 82 149 317 476 896 1447 2492 5250

80 36 76 140 239 443 840 1353 2315 4900

90 33 71 133 275 420 793 1288 2203 4667

100 32 68 126 266 411 775 1246 2128 4518

125 28 60 117 243 369 700 1143 1904 4065

150 25 54 105 215 327 625 1008 1689 3645

175 23 50 93 196 303 583 993 1554 3370

200 22 47 84 182 280 541 877 1437 3160

300 17 37 70 145 224 439 686 1139 2539

• Liquid Propane (LP) Gas flow is

given in thousands of BTU/hr. -

One cubic foot of LP gas - 2516

BTU.

• This chart refers to low

pressure LP, after regulation,

Standard nominal pressure at

the burner for Liquid Propane

Gas is 11” of water column.

• Pipe length must include

additional length for all fittings.

Add approximately 5 feet of

pipe per fitting.

• LP Example: A machine with

a burner that requires 440,000

BTU would need a 1” pip for a

20’ long run.

11 lb. Tank 20 lb. Tank 30 lb. Tank 40 lb. Tank 50 lb. Tank

= 2.98 gal. of gas = 5 gal. of gas = 7 gal. of gas = 10 gal. of gas = 25 gal. of gas

= 256,205 Btu’s = 430,000 Btu’s = 640,000 Btu’s = 860,000 Btu’s = 2,159,400 Btu’s

Page 52: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

52

Quote# Request Date

Distributor:

Phone (Office):

Street Address:

City:

Contact:

Email:

State:

Re-Seller:

Phone (Office):

Street Address:

City:

Contact:

Email:

State:

CONTACT INFO

Project Name:

Expected Need Date:

Zip:

Zip:

PROJECT INFORMATION : Please answer / select all that apply

Project Application: Commercial Residential Certification Required: YES NO

Gas Type: NG (Natural Gas) LP (Liquid Propane)

Please check which item best describes your project:

Complete custom fire feature (Includes Disc or Pan, Burner and Ignition System)

Custom Burner Only (No Pan, No Ignition System) Custom Pan Only

IGNITION TYPE : How to turn it on - Check one

Hot Surface, Electronic Ignition (Requires 120Vac) -

Battery Operated Electronic Ignition (TFS - Thermocouple Flame Sense)(Max 110,000 BTU)

TMS (Thermocouple Manual Safety)

Match Light with Manual Spark Ignition “Piezo” - Battery Operated

Match Light (Light with Butane Lighter)

Ignition Accessories for Electronic Systems - Check all that apply

Timer Emergency Shut Off Wall Switch Remote Control

Remote Control for Electronic Ignition Systems only (max distance is 25’ from appliance)

OPTIONAL: Manual Spark Ignition “Piezo” - Battery Operated

CUSTOM ORDER FORM

125,000 BTU 290,000 BTU 500,000 BTU

Page 53: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

53

ROUND & SQUARE BURNERS : Select or fill in where applicable

Style of Pan

Flat Disc

Pan Style (Round)

Pan Style (Square)

Lip Required

Select One Below InsideOutside Dimension

YES NO

N/A

Size of Lip if different from 1 3/8” each side

LINEAR BURNERS : Fill out where applicable

Dimensions: Width

Linear Burner Flame Pattern : Select One

Length Depth

Field of Fire (H Style) Single Row of Fire

Please help us understand the enclosure that the Custom Burner will be installed in. If you have drawings or pictures, please provide those as attachments. The more details we have the smoother the quote process will be.

ENCLOSURE DETAILS : Select or fill in where applicable

Constructed of: CMU (Concrete Masonry Unit) RTF (Ready to Finish Enclosure)

Height

Paver / Brick

Height & Width of Enclosure:

Width

FINISHING MATERIALS : Select all that apply

Manufactured Stone Real Stone Paver / Brick Stucco Other

VENTILATION : Requires 18 square inches of cross ventilation

Size of vents being installed Do you want Firegear to provide vents? YES NO

ADDITIONAL INFORMATION OR REQUESTS

SAVE FORM BEFORE SENDING

EMAIL TO : [email protected] or FAX T0 : 888.672.8024

Depth

Lip Required YES NO Size of Lip if different from 1 3/8” each side

Burner Flame Expectations

Height of Flame

65,000 to 85,000 BTU 85,000 to 120,000 BTU 250,000 BTU 500,000 BTU

Page 54: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

54

Mail or Email forms to:

Skytech Products GroupDisplay Claims Processing9230 Conservation Way, Fort Wayne IN 46809

Email: [email protected]

DEALER DISTRIBUTOR

ADDRESS

CITY STATE ZIP

CONTACT PHONE FAX

EMAIL WEBSITE

INSTALL DATE SUBMIT DATE

FIREGEAR ITEM #

SERIAL # IF APPLICABLE

INVOICE # COSTDISPLAY

ALLOWANCE %CREDIT

REQUESTED

TOTAL CREDIT REQUESTED

Submit claim form with a photograph of each eligible item and a copy of the original invoice. Photograph must show product burning. Product must remain on display for 12 months from date of submittal. Company reserves the right to charge back the display credit if the display is no longer available for consumer presentations. In order to qualify for Burn Display Allowance must be a functional gas burning display. Product purchased as part of the Firegear Outdoors Kiosk is excluded from the burn / display program.

Burn/Display credits will be issued exclusively toward future purchases of Firegear products.

AUTHORIZED DEALER SIGNATURE / DATEAUTHORIZED DISTRIBUTOR OR SKYTECH / FIREGEAR

FACTORY REPRESENTATIVE SIGNATURE / DATE

SKYTECH PG APPROVAL

CREDIT MEMO #

Burn / Display Credit Form 1-1-17

LIVE BURN PROGRAM

INSTALL LOCATIONADDRESS

CITY STATE ZIP

Page 55: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

55

PHONE: 888.672.8929 FAX: 888.672.8024 EMAIL: [email protected]

CATEGORYCATALOG

PAGE #ELIGIBLE PRODUCTS

ADDITIONAL BURN CREDIT

Outdoor Fireplaces 8 - 9 Kalea Bay 36/48/60/72 50%

10 -11 OD42 20%

12 - 13 Key West See-Thru 40%

Fire Furnishings 16 - 17 Key West Bistro 20%

18 - 19 Key West Coffee Table 20%

Burner Systems 26 - 27 Round Burner Systems - UL Listed 40%

28 - 29 Flat Disc Burner Systems - UL Listed 40%

30 -31 Square Burner Systems - UL Listed 40%

32 - 33 L Series - UL Listed 40%

34 Round/Flat Disc/Square - Non Listed 40%

34 Line of Fire - Non Listed 20%

Assemble and Finish (AnF) 36 - 37 Round/Linear/Square AnF Enclosures 40%

Paver Kit Control Panels 38 - 39 Control Panels & Vent Kits 40%

Jewelry 46 Lava Rock/Lava Stone/Lava Boulder 50%

48 Glass 50%

50 - 51 Log Sets for Fire Pits 50%

Accessories 54 Controls 50%

55 Windshields 50%

56 Lids 50%

57 MSI Kits & Vent Kit 50%

68 Hoses & Regulators 50%

Dealer Tools 63 *Glass Tower 100%

Create a claim form with a photograph of each eligible item and a copy of the original invoice. Photograph must show product burning and must include model #, serial #, distributor/dealer name, physical address of display. Product must remain on display for 12 months from date of submittal. Company reserves the right to charge back the full amount of the display credit if the display is no longer available for consumer presentations. To qualify, Burn Display Allowance must be a functional gas burning display.

Kalea Bay Burn Display Requirements: To qualify for the Live Burn Display, Kalea Bay must have finishing material used to face the unit. If displaying as a See-Through, you may leave one side unfinished. No more than one live Kalea Bay display per location unless approved by Firegear Outdoors in writing. *Dealer can receive 100% credit with proof of purchase of $200 of Firegear Fireglass.

Page 56: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

56

FG-LIT-CATALOG-17

DEALER

ORDER DATE

DISTRIBUTOR

ADDRESS

CITY STATE ZIP

CONTACT PHONE FAX

EMAIL ATTENTION

LITERATURE ORDER FORM

1

2017 CATALOG

THE BEST ROOM IN THE HOUSE

ISN’T IN THE HOUSE AT ALL

1

2017 SPECIFICATION BOOK

THE BEST ROOM IN THE HOUSE

ISN’T IN THE HOUSE AT ALL

2017 PRICE BOOK

THE BEST ROOM IN THE HOUSE

ISN’T IN THE HOUSE AT ALL

AnFAssemble and Finish

BUILDING A FIRE PITHAS NEVER BEEN THIS EASY

2017 CATALOG QUANTITY

FG-LIT-SPEC-172017 SPEC BOOK

FG-LIT-PRICING2017 PRICE BOOK

FG-LIT-ANFAnF LITERATURE

AVAILABLE ONLINE ONLY

QUANTITY

PACKSQUANTITY

only purchased in packs of 25

For special events and large quantities, please allow up to 2 weeks for processing and delivery. Expedited requests requiring express shipping are billable.

FAX or EMAIL forms to: 888.672.8024 or [email protected]

Also available online(See instructions below)

(See instructions below)

INSTRUCTIONS FOR ACCESSING LITERATURE ONLINE

Go to www.firegearoutdoors.comClick on the products tab

Scroll down until you see your desired literature pieceYou can then view, download or share the document!

Page 57: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

57

NOTES

Page 58: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

58

RETURN POLICY

Products that are defective or shipped in error may be returned.

ELIGIBLE PRODUCT

The customer should contact SPG to obtain a Return Material Authorization (RMA) number. The RMA number is required on all paperwork enclosed within the packaged and written on the shipping carton for easy identification upon receipt.

AUTHORIZATION

Each item being returned should be clearly tagged with the reason for the return. This will assist us in evaluating the product and provided a quicker return.

All products should be packaged to prevent damage in shipping. Product damaged during the return will be the responsibility of the customer. Return freight charges are the responsibility of the customer.

TAG & SHIP

It is our goal to evaluate, process and complete each return at our earliest convenience. However, every item returned to SPG is tested and evaluated, so the larger the return, the longer it may take to complete our evaluation. Therefore, we strongly recommend not holding returns for extended periods of time.

TIMING

All defective products must have an RMA issued by one of our technical support staff. To get an RMA please have your original purchase information available and contact the technical support staff. A technical support person will attempt to solve the problem over the telephone. If the technical support staff cannot troubleshoot the problem over the phone, an RMA number will be issued. The RMA number must be indicated on the outside of the returned package and a copy of the RMA worksheet should be within the package if applicable. The RMA is valid for 60 days after issued. Once we receive the product back testing will begin. It is important to note, the return should contain all contents originally shipped or testing will be delayed. If you have any questions on what should be returned, please contact the technical support staff.

DEFECTIVE PRODUCT

Attn. Technical Department9230 Conservation Way, Fort Wayne, IN 46809

P: 855.498.8324 F: 888.672.8024 E: [email protected]

Page 59: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

59

Skytech Products Group (Firegear Outdoors) hereby warrants to the end user that products will be free from material and workmanship defects that prevent safe and correct operation of the product. The warranty commences from date of sale to the end user for the following period:

End User must provide a bill of sale, canceled check, or payment record from the end user to verify purchase date and to establish warranty period. This Limited Warranty shall be valid and limited to the original purchaser only.

WARNING Any modification to the product will void the warranty.

This Limited Warranty shall be limited to the repair and/or replacement of parts that have proven to be defective under normal use and service. Before returning any parts, contact our Technical Service Department for a Return Materials Authorization (RMA) number. All warranty claims must be made by the OEM / Distributor / Dealer account on behalf of the end user. You may contact Technical Service at (855) 498-8324.

All approved returned defects must be confirmed by our Technical Service Department. If the defect is confirmed and we approve the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.

Travel, diagnostic cost, service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner. We will not be responsible for labor charges and/or damage incurred in installation, repair, and replacement.

LIMITED WARRANTY

This Limited Warranty is voided if not assembled, installed and operated as intended. This Limited Warranty does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, removal from the original location or re- installation into another location, or failure to perform normal and routine maintenance.

Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due to over-heating, exposure to chemicals (including salt), either directly or in the atmosphere, or very high humidity, is not covered by this Limited Warranty.

There are no other express warranties except as set forth herein. For consumer applications, any applicable implied warranties of merchantability and fitness are limited induration to the period of coverage of this Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you.

For Commercial applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular purpose or merchantability.

We are not liable for any special, indirect or consequential damages. Our maximum liability is limited to the purchase price of the purchased products. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusions may not apply to you.

We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such representations are binding.

Lava Rock and Lava Stones are not covered by warranty

CONSUMER/NON-COMMERCIAL APPLICATIONS:Stainless Steel Components 5 YearsGas Valve, Spark Igniter & Electronic Parts 2 YearsLog Sets 3 YearsGlass Windshields 5 YearsGlass Media 1 YearControls 5 YearsAnF Enclosures 5 Years

COMMERCIAL APPLICATIONS:Stainless Steel Components 1 YearGas Valve, Spark Igniter & Electronic Parts 1 YearLog Sets 1 YearGlass Windshields 1 YearGlass Media 1 YearControls 1 YearAnF Enclosures 1 Year

Lava Rock and Lava Stones are not covered by warranty

Page 60: 2017 SPECIFICATION BOOK ISN’T IN THE HOUSE AT ALL · 2017 specification book the best room in the house isn’t in the house at all ver 04-11-17. 2 item page number outdoor fireplaces

60

TECHNICAL SUPPORT:

9230 CONSERVATION WAY

FORT WAYNE, IN 46809

1.855.498.8324SALES SUPPORT: 1.888.672.8929

www.firegearoutdoors.com

FG-LIT-SPEC-17