OPTIONAL PARTS FOR SPLIT & MULTI SPLIT
OPTIO
NAL PARTS for SPLIT &
MULTI SPLIT
122 123
OPTIONAL PARTS FOR SPLIT & MULTI SPLIT
Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-W / UTD-GXSC-W
Flexible Control• Operation with indoor unitAuto Louver can be operated by synchronizing remote controller of indoor unit.
• UP and Down auto swing• Auto airflow direction and auto swing• 4 steps selectable
• Auto-closing louverWhen operation of indoor unit is stopped, the louver will automatically close.
Dimensions
Simple flat Auto Louver will provide comfortairflow and harmonize with luxury interior.
Closed louver Opened louver
Controller Controller
Duct type
Wired Remote Wireles Remote
Auto Louver Grille
UTD-GXSA-W
W1 W2
683
883
1,083
645
845
1,045
180 148 9 84
Unit: mm
Model Name H1 H2 D1 D2
UTD-GXSB-W
UTD-GXSC-W
W1
W2
D2D1
H1 H2
Fitting Flame
Grille
Net
Gross
Cooling
Heating
kg(lb.)
% RH
°C (°F)
°C (°F)
Model name
Applicable Indoor Unit
Power Supply
Fixing of Auto Louver Grille
Extension Square Duct Limit
Color
Louver Motor
Accessories
Operation range
Weight
ARYG07/09LLTA ARYG12/14LLTB
ARXD04/07/09/12/14GALH (For VRF)
180x683x(84+9)
[7-3/32x26-7/8x(3-5/16+11/32)]
2.0 (4.4)
3.0 (6.7)
UTD-GXSA-W
ARYG18LLTB ARXD18GALH (For VRF)
180x883x(84+9)
[7-3/32x34-3/4x(3-5/16+11/32)]
2.5 (5.6)
3.5 (7.8)
White
Stepping Motor
Fitting Flame, etc.
18 to 32 (64 to 90)
80% or less
16 to 30 (60 to 88)
Connecting with Control box of indoor unit
Screw fixing to Flange or Square Duct
1.0m (Max. duct length between indoor unit and Grille)
UTD-GXSB-W
ARXD24GALH (For VRF)
180x1083x(84+9)
[7-3/32x42-5/8x(3-5/16+11/32)]
3.0 (6.7)
4.0 (8.9)
UTD-GXSC-W
mm(inch)
Net Dimension(H x W x D)
Specifications
Wired Remote Controller : UTY-RVNYM
High performance and compact size•In addition to the individual control, various energy saving controls can be realized using only one remote controller.
Various energy saving functionAuto OFF Timer
• The indoor unit automatically is turned off when it reaches the preset operating time frame.
• The time frame of the "Auto off timer" can be flexibly scheduled.
• Can be set off time 30 to 240 minutes
Weekly Timer function• Can be set up to 8 times per day (On/Off, mode,Temp)
• 2 pattern settings(i.e. Summer/Winter setting) are available.
High visibility and Easy operation• Icon display of effectual functions.
• Main functions in large icons: "Mode", "Set Temp", and "Fan".
• Easy to operate by Control guide display.
• Simple operation with easy 4-way navigation pad.
Set Temperature Auto Return• The setting temperature automatically returns to the previously set
temperature.
• The time range in which the set temperature can be changed is 30 to 120 minutes.
Set Temperature Upper and Lower Limit Setting• The set temperature range can be set for each operation mode.
(Cooling / Heating / Auto)
Specifications
Max.controllable
16Indoor units
Model name
Power supply
Dimension (H × W × D) (mm)
Weight (g)
* DC12 V is supplied by indoor unit.
UTY-RVNYM
DC 12 V
120 × 120 × 21.3
220
Hi-grade individual control using various functions.
• 3.7-inch LCD backlight screen. • Supporting various Energy Saving functions with simple operation. • Multiple Language Support.
(English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)
Individualcontrol
Thermosensor
Weeklytimer
Auto off timer
Setting temp.Cooling operation
24°C22°C
Set temperature change Auto return
AM11:40 PM1:40 AM11:40 PM1:40Time
Settable time range30 to 120 minutes
Setting temp.Heating operation
25°C23°C
Set temperature change Auto return
Time
Settable time range30 to 120 minutes
AM10:00 PM12:00 2:00 5:00 8:00 11:59
Weekly 1
Set T
emp.
(°C
)
Time
28
222324252627
26°C 26°C
28°C27°C
Setting menu in remote controller
26°C25°C 25°C
On
Off
Weekly 2
Set T
emp.
(°C
)
Time
26
202122232425
24°C 24°C
22°C 22°C
Setting menu in remote controller
24°C
26°C 26°C
On
Off
AM10:00 PM12:00 2:00 5:00 8:00 11:59
Original temp.setting range
Lower limitsetting
During Cooling30°C
25°C
18°COriginal temp.setting range
Upper limitsetting
During Heating30°C
25°C
16°C
Icon display (weekly time)
Set temperature
Control guide display
S p l i tO
PTION
AL PARTS for SPLIT & M
ULTI SPLIT
124 125
OPTIONAL PARTS FOR SPLIT & MULTI SPLIT
For Cassette type
For Floor type
Fresh Air Intake KitUTZ-VXGA
For Compact Cassette type
Shuts the air outlet when only using as 3 blow out.
Air Outlet Shutter PlateUTR-YDZB
Shuts the air outlet when only using as 3 blow out.
Air Outlet Shutter PlateUTR-YDZC
IR Receiver KitUTY-LRHYA2
This kit is used to half conceal floor type indoor unitinto the wall.
For Compact Cassette type
Fresh Air Intake KitUTZ-VXAA
UTR-STAHalf Concealed Kit
Indoor unit950
Panel 600
600(mm)
UTG-AGYA-WWide Panel
Panel Spacer
Panel spacer
242 mm
UTG-BGYA-W
UTZ-KXGA / UTZ-KXGCInsulation Kit For High Humidity
For Compact Cassette type / Cassette type
Insulation Kit
For Ceiling type
Drain Pump UnitUTR-DPB24T
Communication KitUTY-TWBXF / UTY-XCBXZ1 /UTY-XCBXZ2
Service Monitoring ToolUTY-ASSX
Communication devices
UTY-RNNYM / UTB-YUDWired Remote Controller
UTY-RVNYMWired Remote Controller Simple Remote Controller
UTY-RSNYM / UTB-YPB UTY-DMMYMFor 8 Rooms Multi
Central Remote Controller
ControllersFor Individual & Centralized Control
Cassette Grille
For Compact Cassette type
UTG-UFYD-W Cassette GrilleUTG-UGYA-W
For Compact Wall Mounted type
Communication Kit
Service & Maintenance
For Duct type
IR Receiver KitUTY-LRHYM / UTY-LRHY1 / UTY-LRJY1
Auto Louver Grille KitUTD-GXSA-W For 07 / 09 / 12 / 14 type
UTD-GXSB-W For 18 type
Long-Life Filter
UTZ-PX1NBA / UTZ-PX1BBA
UTD-LF60KAUTD-LF25NA
UTD-LF60KA UTD-LF25NA
Remote Sensor UnitUTY-XSZX / UTD-RS100New amenity space can be offered by installing the Remote sensor.
Drain Pump UnitFlangeUTD-RF204 (Round)UTD-SF045T (Square)
(Round) (Square)
+ or
For Compact / MediumStatic Pressure Duct
Others
External Control SetFor Indoor Unit
UTD-ECS5AUTY-XWZX UTY-XWZXZ5
External Connect KitFor Outdoor unit
UTY-XWZXZ4UTY-XWZXZ3UTY-XWZXZ2
External Connect KitFor Indoor Unit
External Connect Kit / External Control set
Input
* 1 : This function has been had only wall mounted model such as LT, LU, and LM.* 2 : This function has been had only ducted model, cassette model , and ceiling mode.* 3 : This function has been had only ducted model.* 4 : This cable is necessary for some ducted model.
Output
Function list
UTY-XWZXZ2—●●——●●————
For Outdoor unit
UTY-XWZXZ3—●●●●●●————
UTY-XWZXZ4——————————●
UTD-ECS5A●————●
●*1
●*2
●*3
●*4
—
For Indoor unit
UTY-XWZXZ5●————●●————
UTY-XWZX●————●—————
ControlPeak cutLow noisePriorityEmergency stopOperation statusError statusFresh air controlAuxiliary heaterPreparationBase heater
For Compact Cassette type
Additional GrilleUTG-AGDA-W
Additional GrilleUTG-AGEA-W
For Compact Cassette type
Cassette GrilleUTG-UDYD-W