2015 doe hydrogen and fuel cells program review · 2015. 6. 11. · this presentation does not...

24
NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. This presentation does not contain any proprietary, confidential, or otherwise restricted information Renewable Electrolysis Integrated System Development & Testing Kevin Harrison, Michael Peters* , Danny Terlip June 11, 2015 Project ID: PD031 2015 DOE Hydrogen and Fuel Cells Program Review *Presenter

Upload: others

Post on 03-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC.

This presentation does not contain any proprietary, confidential, or otherwise restricted information

Renewable Electrolysis Integrated System Development & Testing

Kevin Harrison, Michael Peters* , Danny Terlip

June 11, 2015Project ID: PD031

2015 DOE Hydrogen and Fuel Cells Program

Review

*Presenter

Page 2: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

2

Overview

Project start date: Sep. 2003Project end date: Oct. 2015*

FY13 DOE Funding: $460kFY14 DOE Funding: Forward funded with FY13 fundsFY15 DOE Planned Funding: $200kTotal Project Value: $5,900k

Timeline

Budget

Barriers

Partners

* Project continuation and direction determined annually by DOE

G. System EfficiencyI. Grid Electricity Emissions (Distributed)J. Renewable Electricity Generation

Integration (Central)L. Operations and Maintenance

Xcel Energy (CRADA)Proton OnSiteGiner Inc.

Page 3: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

3

Relevance• Hydrogen is a storage fuel enabling higher penetrations of

renewable electricity sources• Electrolyzer systems are rapidly increasing in size and are

able to provide:• Renewable hydrogen for a near-zero carbon

transportation fuel• Utility grid services and stabilization

Page 4: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

4

Impact• As electrolyzer systems size increase there is a need to

validate large active area stacks to meet DOE targets• System efficiency under varying power operation (e.g.,

solar, wind) needs to be optimized to account for theintermittency of renewable energy sources

Individual Cell Voltage Measurements

Page 5: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

5

Approach• Provide independent performance testing of advanced electrolyzer

stacks and systems for DOE and Industry• Develop and optimize electrolyzer stack and sub-system

performance using grid and renewable power systems• Leverage large active area stack testing platform and balance of

plant to develop system efficiency improvements

Collaborate with other NREL projects and industry

• INTEGRATE project TV030 providedelectrolyzer stack test bed andhydrogen dryer

• Quality results collected as part of700 bar station operation

• Giner Inc. provided test stack tocommission stack test bed

Page 6: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

6

Approach

Milestone Description Type Due Date

Provide comparison of four different drying technologies, focusing on efficiency, capital cost and O&M cost of the different techniques. If there is a technique that has not been tested but shows promise in the Q1 detailed analyses, the technique may be

designed, procured, implemented and tested.

Qtr Progress Measure (Regular)

31-Dec-14

Install and begin testing large active area stack drying system, comparing fixed flow versus variable flow desiccant drying systems. Confirm drying system removes

moisture content below 5 parts per million of water in hydrogen (as per SAE J2719) for PEM stacks capable of hydrogen production in the 65+ kg/day range.

Qtr Progress Measure (Regular)

31-Mar-15

Collect 40 hours each on 3 different pressure swing adsorption drying techniques comparing the fixed flow (orifice) approach with two new linear actuated valves

(variable flow) that vary in performance and price.

Annual Milestone (Regular)

30-Jun-15

Complete cumulative testing of 7500 h for two PEM electrolyzer stacks and 4500 h for a new stack under constant- and variable-powered operating conditions and compare

stack decay rates of the two operational modes with results from FY14.

Qtr Progress Measure (Regular)

30-Sep-15

Page 7: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

7

Technical AccomplishmentCompare Stack Lifetime: Wind vs. Constant Power Operation• Goal: Analyze stack decay differences between constant- and

variable-powered stack operation• Three 10 kW stacks under test• ~5,500 hour operation completed

• Proton Onsite (H-Series) – 40 kW, 13 kg/day PEM electrolyzer• Instrumented electrolyzer and took control of AC/DC power supplies

to operate stacks in variable power mode

0

50

100

150

200

0 10 20 30 40 50 60Stac

k Cu

rren

t (Am

ps)

Time (min)

Variable versus Constant Operation

Variable Profile Avg of 80%Constant Power at 80%

A B C

Page 8: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

8

Long Duration Variable Stack Testing• Stack A & B reached 5,500 hours of

operation, newer stack C reached 2,500hours of operation

• Stack decay rate calculated by running thestacks at steady-state (~155 Amps) andseparating into temperature and voltage bins

• Voltage comparison of the three stacks at104 oF is used to determine stack decay rate

Operating Mode

Stack Identifier

Decay Rate (μV/cell-h)

Variable Power

Stack A 11.5

Constant Power

Stack B 12.6

Constant Power

Stack C 21.6

Technical Accomplishment

71727374757677

85 90 95 100 105Stac

k Vo

ltage

(Vol

ts)

Temperature (oF)

Example of Sorted Steady-state Data

Jun-13Apr-15

Page 9: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

9

NREL Electrolyzer Stack Test BedLocated at NREL’s Energy System Integration Laboratory• AC-DC power supplies capable of

2,000 ADC and 250 VDC• Built as a collaboration with the

INTEGRATE projectSystem efficiency improvements in electrolyzer balance of plantGoal is to improve system efficiency;• Drying losses in variable

operation with NREL’s variableflow drying technique• NREL designed and Proton built

research drying skid• Optimize balance of plant based

on variable stack power

First testing completed with Giner Inc.• Three 150 kW PEM stacks• IV-Curves were collected at stack

temperature of 70 oC• Individual cell voltages were

collected at different current andstack pressure levels

Page 10: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

10

Technical AccomplishmentsAbility to program profiles into the stack test bed• Examples of renewable and regulation profiles• Ran profiles with 120 kW stack from Proton

14:10 14:15 14:20 14:25 14:30 14:35 14:40 14:45 14:50 14:55700

800

900

1000

1100

1200

Time of Day

Sta

ck C

urre

nt (A

)

Regulation

0 1 2 3 4 5400

600

800

1000

1200

Runtime (min)

Sta

ck C

urre

nt (A

mps

)

Wind (Highly Variable)

06:00 09:00 12:00 15:00 18:00

200

300

400

500

600

700

Time of Day

Sta

ck C

urre

nt (A

mps

)

PV Winter (1/1/2015 Data)

03:00 06:00 09:00 12:00 15:00 18:00 21:00200

400

600

800

1000

1200

Time of Day

Sta

ck C

urre

nt (A

mps

)

PV Summmer (7/4/2014 Data)

Stack CurrentStack Command

Stack Current Stack Current

Stack Current

Page 11: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

11

Technical AccomplishmentsLarge active area stack testing and

hydrogen dryer improvements• Challenge: Traditional H2 drying systems

are designed to operate at full power with afixed amount of H2 lost regardless ofoperating conditions

• Goal: Improve electrolyzer efficiency byoptimizing electrolyzer balance of plantoperation under variable conditions

• Approach: Reduce H2 drying losses in pressure swing adsorption dryers to less than 3.5% of flow using variable flow approach

• Testing aims to confirm H2 quality is notcompromised with real time monitoring ofwater content in the H2

Page 12: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

12

Technical AccomplishmentsVariable flow drying concept developed and installed• Replace fixed orifice used in pressure swing adsorption (PSA) dryers

with a linear actuated valve to accommodate varying hydrogen flow• Currently testing 3 different PSA concepts (A – C):

• A – (Control) fixed orifice,typically seen in electrolyzers

• B – Variable flow valve,electrically actuated

• C – Variable flow valve,pneumatically actuated

Page 13: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

13

Technical AccomplishmentsMeasuring Dryer Performance• Dew point sensors on outlet of dryer are used to track parts per

million by volume (ppmv) of H2O in the H2• SAE J2719 fuel quality standard is mandatory

target, < 5 ppmv• Dew point sensors are known to have issues

during operation. Solutions to overcome dewpoint sensor challenges:• Challenges: Dew point sensors having

erratic behavior, Dew point sensors driftover time

• Solutions: Install multiple dew pointsensors, filter data when needed, N2 purgesystem to sweep any contaminants off ofthe sensors when needed

Page 14: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

14

Technical AccomplishmentsHydrogen savings with variable flow• Preliminary analysis of why these savings are important• Systems are growing in size, real savings happen as larger systems

come online

0

200

400

600

800

1000

1200

Wind PV Reg Wind PV Reg

120 kW 1 MW

Tota

l Hyd

roge

n Sa

ved

(kg/

year

)

System Size

Hydrogen Saved per Year with Variable Flow Approach

Page 15: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

15

CollaborationsFormal

Giner Inc.• Work for Others• Tested (3) 150 kW stacks

Xcel Energy (CRADA)• Wind-to-Hydrogen demonstration project since 2005

Internal to NREL700 bar hydrogen station

• Quality resultsINTEGRATE

• Large active area stack test bed• H2 drying system

Page 16: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

16

Future Work

• Finalize testing and report on on-going dryer testing to optimizedrying losses

• Continue long duration testing comparing stack decay rates forvariable power operation and constant power operation

• Find other opportunities to use the electrolyzer balance of plantto improve system efficiency• Capturing heat to warm up H2 sweeping gas to lose less H2 in

drying• Using cooling system and H2O drop outs to improve dryer

efficiency

Page 17: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

17

Responses to Previous Year Reviewers’ Comments

• This project was not reviewed last year

Page 18: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

18

SummaryRelevance: Goals consistent with reducing capital cost, improving stack and system efficiency and integrating systems with renewable energy sources

Approach: Develop and demonstrate advanced controls, novel sub-systems, system-level improvements and integrate with renewable energy sources to reduce the cost of hydrogen

Technical Accomplishments:• Reached 5,500 hours of operation on (3) 10 kW stacks to analyze stack decay differences between

constant- and variable-powered stack operation• Stacks showed a decay rate of 11 - 22 μV/cell-h

• Collaborated with INTEGRATE to build electrolyzer stack test bed• Purchased, installed, commissioned and began testing H2 variable dryer concept

• Installed linear valves and orifice in parallel paths for testing• Solved dew point challenges

Collaborations:• Giner Inc. - Large active area stack testing• Internal - 700 bar station, INTEGRATE

Proposed Future Research:• Finalize testing and report on on-going dryer testing to optimize drying losses• Continue long duration testing comparing stack decay rates for variable power operation and constant

power operation• Find other opportunities to use the electrolyzer balance of plant to improve system efficiency

Page 19: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

19

Technical Backup Slides

Page 20: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

20

Dew Point Sensor Drift Over Time

Page 21: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

21

Dew Point Sensor Erratic Behavior

08:30 09:00 09:30 10:00 10:30 11:00 11:30 12:00 12:30 13:00 13:300

1

2

3

4

5

6

7

8x 10

9

Time

Dewp

oint p

pmv

Dewpoint Sensor Raw Data, Erratic Behaviour

08:30 09:00 09:30 10:00 10:30 11:00 11:30 12:00 12:30 13:00 13:300

5

10

15

20

25

30

35

40

45

Time

Dewp

oint p

pmv

Dewpoint Data Filtered (<100 ppmv)

Page 22: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

22

Hydrogen Savings Analysis DetailsAssumptions• Estimates on installing/implementing one linear actuated valve on

one system based on experience. Cost would go down as more valvesare implemented and controls are duplicated

• Price of H2 6 – 10 $/kg• Valve Costs Hardware:

• Valve, Linear Actuator• Valve Costs Labor:

• Installation, Controls

Page 23: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

23

120 kW 250 kW 500 kW 750 kW 1 MW 2 MW0

1

2

3

4

5

6

7Linear Valve Breakeven Point versus System Size

System Size

Num

ber o

f Yea

rs

Linear Valve Breakeven

Page 24: 2015 DOE Hydrogen and Fuel Cells Program Review · 2015. 6. 11. · This presentation does not contain any proprietary, confidential, or otherwise restricted information. Renewable

24

Technical AccomplishmentsDryer Characteristics• Calculated flow based on stack current for the

120 kW stack from Proton• 52 kg/day

• Initial drying losses calculated at• 9 – 11 kg/day• 17 – 21% of H2 lost

• Drying system designed for 135 kg/day• 6 – 8 % of H2 lost theoretically

• Added control valve on vent line to reducelosses to < 10% at full operation