2011 cardiacsurgery catalog us 062811
TRANSCRIPT
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
1/60
Cardiac Surgery
U.S. Product Catalog
May 2011
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
2/60
Table of Contents
Tissue Heart Valves
Aortic Supra-Annular Stented Valves
TrifectaStented Tissue Valve with Linx AC Technology ........................................................................TH2
EpicSupra Stented Tissue Valve with LinxAC Technology ...................................................................TH3
Biocor Supra Stented Tissue Valve .......................................................................................................TH4
Aortic Stented Valves
EpicStented Tissue Valve with LinxAC Technology .............................................................................TH5
Biocor Stented Tissue Valve .................................................................................................................TH6
Mitral Stented ValvesEpicStented Tissue Valve with LinxAC Technology .............................................................................TH7
Biocor Stented Tissue Valve .................................................................................................................TH8
Accessories
Trifecta Valve Sizer Set ........................................................................................................................TH9
Bioprosthetic Heart Valve Sizer Set .......................................................................................................TH10
Mechanical Heart Valves
Aortic Valves
Regent Mechanical Heart Valve ...........................................................................................................MH2
Masters HPMechanical Heart Valve ....................................................................................................MH4
Masters Series Mechanical Heart Valve .................................................................................................MH7
Mitral Valves
Masters HPMechanical Heart Valve ..................................................................................................MH10 Masters Series Mechanical Heart Valve ...............................................................................................MH11
Aortic Valved Grafts
Masters HPValved Graft with Gelweave ValsalvaTechnology .............................................................MH15
Masters Valved Graft with Hemashield Technology.............................................................................MH16
Accessories
RegentMechanical Heart Valve Sizer Set ..........................................................................................MH17
SJMMechanical Heart Valve Sizer Set ...............................................................................................MH18
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
3/60
Table of Contents
Valve Repair
Flexible Rings and Band
AttuneFlexible Adjustable Annuloplasty Ring .......................................................................................VR2
TailorFlexible Annuloplasty Ring ..........................................................................................................VR3
TailorFlexible Annuloplasty Band .........................................................................................................VR4
Rigid / Semi-Rigid Rings
SJMRigid Saddle Ring ........................................................................................................................VR5
SJMSguin Semi-Rigid Annuloplasty Ring ...........................................................................................VR6
Pericardial Patch SJMPericardial Patch with EnCapAC Technology ..............................................................................VR7
Accessories
TailorAnnuloplasty Ring Sizer Set ........................................................................................................VR8
SJMRigid Saddle Ring Sizer Set ..........................................................................................................VR9
SJMSguin Semi-Rigid Annuloplasty Ring Sizer Set ...........................................................................VR10
Tailorand AttuneRing Robotic Sizer Set...........................................................................................VR11
Cardiac Ablation
EpicorCardiac Ablation System
EpicorAblation Control System (ACS)...................................................................................................CA2
EpicorLP Cardiac Ablation System
UltraCinchLP Ablation Device .............................................................................................................CA3
UltraWandLP Handheld Ablation Device ..............................................................................................CA4 LP Connecting Cable..............................................................................................................................CA5
LP Positioning and Sizing (LP PAS) System ............................................................................................CA6
LP Oblique Introducer ............................................................................................................................CA7
Universal IV Set .....................................................................................................................................CA8
Cardiac Surgery Catalog Reorder Number Index
Terms of Sale
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
4/60
Tissue Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
5/60
Tissue Heart Valves Table of Contents
Tissue Heart Valves
Aortic Supra-Annular Stented Valves
TrifectaStented Tissue Valve with Linx AC Technology ........................................................................TH2
EpicSupra Stented Tissue Valve with LinxAC Technology ...................................................................TH3
Biocor Supra Stented Tissue Valve .......................................................................................................TH4
Aortic Stented Valves
EpicStented Tissue Valve with LinxAC Technology .............................................................................TH5
Biocor Stented Tissue Valve .................................................................................................................TH6
Mitral Stented ValvesEpicStented Tissue Valve with LinxAC Technology .............................................................................TH7
Biocor Stented Tissue Valve .................................................................................................................TH8
Accessories
Trifecta Valve Sizer Set ........................................................................................................................TH9
Bioprosthetic Heart Valve Sizer Set .......................................................................................................TH10
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
6/60
Total Height AorticProtrusion
Tissue Annulus Diameter
Cuff Outer Diameter
1. St. Jude Medical. Trifecta Valve, Pre-Market Approval Application Summary of Safety and Effectiveness Data, P100029, 2011.
2. Data on File, St. Jude Medical.
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
Rx Only
Brief Summary:Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions,
potential adverse events and directions for use.
Indications:The Trifecta Valve is indicated as a replacement for a diseased, damaged, or malfunctioning native or prosthetic aor tic heart valve. Adverse events
potentially associated with the use of bioprosthetic hear t valves include: angina, cardiac arrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia,hemorrhage, leak (transvalvular or perivalvular), myocardial infarction, nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or
positioning, or other), prosthesis regurgitation, stroke, structural deterioration (calcification, leaflet tear, perforation, or other), thromboembolism and valve
thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term low dose aspirin, unless
contraindicated, is recommended for all patients with bioprosthetic valves. Long-term anticoagulant therapy, unless contraindicated, is recommended for all
patients with bioprosthetic valves who have risk factors for thromboembolism. Please see the Instructions for Use (IFU) for a full description of indications,
contraindications, side effects, precautions, warnings and Instructions for Use.
Trifecta Linx ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
TrifectaStented Tissue Valve
with LinxAC TechnologyAortic Supra-Annular Stented Valves
Product Highlights Exceptional hemodynamic performance1
Exterior-mounted pericardial leaflets with unique suture attachment allows for
maximum leaflet excursion and large EOAs2
Designed to provide excellent durability with the pericardial-covered stent for
tissue-to-tissue contact to reduce the risk of abrasion
Includes LinxAC Technology, which is designed to improve long-term performance
and valve durability*
Designed to maintain structural integrity with a high-strength, fatigue-resistant,
titanium alloy stent2
Short 2 x 10-second rinse time
Ordering InformationContents: Aortic Supra-Annular Stented Tissue Valve (1 unit per box)
Model/Reorder
Number
Valve Size
(mm)
Tissue Annulus
Diameter
(mm)
Cuff
Outer
Diameter (mm)
Aortic
Protrusion
(mm)
Total
Height
(mm)
TF-19A 19 19 24 12 15
TF-21A 21 21 26 13 16
TF-23A 23 23 28 13 17
TF-25A 25 25 31 14 18
TF-27A 27 27 33 15 19
TF-29A 29 29 35 16 20
Tissue Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
7/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
8/60
InternalDiameter
AorticProtrusion
TotalHeight
TissueAnnulusDiameter
Tissue Heart Valves
Ordering InformationContents: Aortic Supra-Annular Stented Tissue Valve (1 unit per box)
BiocorSupra Stented Tissue ValveAortic Supra-Annular Stented Valves
Product Highlights Provides a larger stent-to-annulus ratio than Biocor Aortic Valve
Delivers proven 20-year durability results1,2
Three separate porcine leaflets are matched to optimize leaflet coaptation
and reduce stress
The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue
interface to reduce the risk of abrasion FlexFitstent reduces leaflet stress, adapts easily to annulus to enhance knot
positioning, and returns stent posts to original shape after deflection
Low profile design provides optimal coronary ostia clearance
Short 2 x 10 second rinse time
Model/Reorder
Number
Valve
Size
(mm)
Tissue
Annulus
Diameter (mm)
Internal
Diameter
(mm)
Aortic
Protrusion
(mm)
Total
Height
(mm)
BSP100-19 19 19 19 11 14
BSP100-21 21 21 21 11 15
BSP100-23 23 23 23 13 16
BSP100-25 25 25 25 13 17
BSP100-27 27 27 27 14 19
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.
2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.
2008;86(4):1204-1210.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
9/60
InternalDiameter
AorticProtrusionTotal
Height
TissueAnnulusDiameter
Ordering InformationContents: Aortic Stented Tissue Valve (1 unit per box)
EpicStented Tissue Valve
with LinxAC TechnologyAortic Stented Valves
Product Highlights Identical in design to the Biocorstented tissue valve which delivers proven
20 year durability results1
Includes Linx AC Technology which is designed to improve long-term performance
and valve durability*
Three separate porcine leaflets are matched to optimize leaflet coaptation andreduce stress
The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue
interface to reduce the risk of abrasion
FlexFitstent reduces leaflet stress, adapts easily to annulus to enhance knot
positioning, and returns stent posts to original shape after deflection
Low profile design provides optimal coronary ostia clearance
Short 2 x 10 second rinse time
Tissue Heart Valves
Model/Reorder
Number
Valve
Size
(mm)
Tissue
Annulus
Diameter (mm)
Internal
Diameter
(mm)
Aortic
Protrusion
(mm)
Total
Height
(mm)
E100-21A-00 21 21 19 9 14
E100-23A-00 23 23 21 9 15
E100-25A-00 25 25 23 10 16
E100-27A-00 27 27 25 11 17
E100-29A-00 29 29 27 12 19
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Epic Linx Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
10/60
InternalDiameter
AorticProtrusionTotal
Height
TissueAnnulusDiameter
Tissue Heart Valves
Ordering InformationContents: Aortic Stented Tissue Valve (1 unit per box)
BiocorStented Tissue ValveAortic Stented Valves
Product Highlights Delivers proven 20 year durability results1,2
Three separate porcine leaflets are matched to optimize leaflet coaptation
and reduce stress
The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue
interface to reduce the risk of abrasion
FlexFit
stent reduces leaflet stress, adapts easily to annulus to enhance knotpositioning, and returns stent posts to original shape after deflection
Low profile design provides optimal coronary ostia clearance
Short 2 x 10 second rinse time
Model/Reorder
Number
Valve
Size
(mm)
Tissue
Annulus
Diameter (mm)
Internal
Diameter
(mm)
Aortic
Protrusion
(mm)
Total
Height
(mm)
B100-21A-00 21 21 19 9 14
B100-23A-00 23 23 21 9 15
B100-25A-00 25 25 23 10 16
B100-27A-00 27 27 25 11 17
B100-29A-00 29 29 27 12 19
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.
2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.
2008;86(4):1204-1210.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
11/60
InternalDiameter
VentricularProtrusion
TotalHeight
TissueAnnulusDiameter
Tissue Heart Valves
Ordering InformationContents: Mitral Stented Tissue Valve (1 unit per box)
EpicStented Tissue Valve
with LinxAC Technology
Mitral Stented Valves
Product Highlights Identical in design to the Biocorstented tissue valve which delivers proven
20 year durability results1,2
Includes Linx AC Technology which is designed to improve long-term performance and
valve durability*
Three separate porcine leaflets are matched to optimize leaflet coaptation and reduce stress
The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue interface
to reduce the risk of abrasion
FlexFitmitral valve holder provides stent deflection (ratcheting), which reduces the potential
for suture looping and maximizes visibility and access to the valve cuff
Low combined valve and holder height facilitates minimally invasive
surgical procedures
Low profile design reduces the risk of LV outflow tract obstruction
FlexFit stent reduces leaflet stress, adapts easily to annulus to enhance knot positioning,
and returns stent posts to original shape after deflection
Short 2 x 10 second rinse time
Model/Reorder
Number
Valve
Size (mm)
Tissue Annulus
Diameter (mm)
Internal
Diameter (mm)
Ventricle
Protrusion (mm)
Total
Height (mm)
E100-25M-00 25 25 23 9 16
E100-27M-00 27 27 25 9 17
E100-29M-00 29 29 27 10 19
E100-31M-00 31 31 29 10 20
E100-33M-00 33 33 31 11 20
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.
2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.
2008;86(4):1204-1210.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Epic Linx Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
12/60
InternalDiameter
VentricularProtrusion
TotalHeight
TissueAnnulusDiameter
Tissue Heart Valves
Ordering InformationContents: Mitral Stented Tissue Valve (1 unit per box)
BiocorStented Tissue ValveMitral Stented Valves
Product Highlights Delivers proven 20-year durability results1,2
Three separate porcine leaflets are matched to optimize leaflet coaptation and
reduce stress
The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue
interface to reduce the risk of abrasion
FlexFit
mitral valve holder provides stent deflection (ratcheting), which reducesthe potential for suture looping and maximizes visibility and access to the valve cuff
Low combined valve and holder height facilitates minimally invasive
surgical procedures
Low profile design reduces the risk of LV outflow tract obstruction
FlexFit stent reduces leaflet stress, adapts easily to annulus to enhance knot
positioning, and returns stent posts to original shape after deflection
Short 2 x 10 second rinse time
Model/Reorder
Number
Valve
Size
(mm)
Tissue
Annulus
Diameter (mm)
Internal
Diameter
(mm)
Ventricle
Protrusion
(mm)
Total
Height
(mm)
B100-25M-00 25 25 23 9 16
B100-27M-00 27 27 25 9 17
B100-29M-00 29 29 27 10 19
B100-31M-00 31 31 29 10 20
B100-33M-00 33 33 31 11 20
*There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.
1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.
2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.
2008;86(4):1204-1210.
Rx Only
St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic
anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,
suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and
valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/
or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.
Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.
Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
13/60
Tissue Heart Valves
TrifectaValve Sizer SetAccessories
Product Highlights Designed to facilitate proper size selection of the Trifecta Tissue Valve
Sizes 19 mm 29 mm
The cylindrical end determines the appropriate size of the annulus
The corresponding valve replica end is used to visualize supra-annular placement
Features click-in handle for quick attachment to valve holder
Malleable Nitinol sizer and handle can be bent in any direction (up to 90 degrees)
without degradation
Sizer and holder handle return to original, straight shape during sterilization
Model/Reorder
Number Description
TF2000 Trifecta Valve Sizer Set, Complete
UT2000 Flexible Holder Handle
UT2000-R Rigid Holder Handle
EX2000-R Rigid Extension Handle
Ordering InformationContents: 6 Double-ended Aortic Sizers, 1 Valve Holder Handle and 1 Autoclavable Tray with Cover (1 unit per box)
Rx Only
Brief Summary:Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions,
potential adverse events and directions for use.
Indications:The Trifecta Valve is indicated as a replacement for a diseased, damaged, or malfunctioning native or prosthetic aor tic heart valve. Adverse events
potentially associated with the use of bioprosthetic hear t valves include: angina, cardiac arrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia,hemorrhage, leak (transvalvular or perivalvular), myocardial infarction, nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or
positioning, or other), prosthesis regurgitation, stroke, structural deterioration (calcification, leaflet tear, perforation, or other), thromboembolism and valve
thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term low dose aspirin, unless
contraindicated, is recommended for all patients with bioprosthetic valves. Long-term anticoagulant therapy, unless contraindicated, is recommended for all
patients with bioprosthetic valves who have risk factors for thromboembolism. Please see the Instructions for Use (IFU) for a full description of indications,
contraindications, side effects, precautions, warnings and Instructions for Use.
Trifecta ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
14/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
15/60
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
16/60
Mechanical Heart Valves Table of Contents
Mechanical Heart Valves
Aortic Valves
Regent Mechanical Heart Valve ...........................................................................................................MH2
Masters HPMechanical Heart Valve ....................................................................................................MH4
Masters Series Mechanical Heart Valve .................................................................................................MH7
Mitral Valves
Masters HPMechanical Heart Valve ..................................................................................................MH10
Masters Series Mechanical Heart Valve ...............................................................................................MH11
Aortic Valved Grafts
Masters HPValved Graft with Gelweave ValsalvaTechnology .............................................................MH15
Masters Valved Graft with Hemashield Technology.............................................................................MH16
Accessories
RegentMechanical Heart Valve Sizer Set ..........................................................................................MH17
SJMMechanical Heart Valve Sizer Set ...............................................................................................MH18
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
17/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
Effective
Orifice Area6
(cm2) Cuff Style
19AGN-751 19 17.8 2.39 1.84 Standard
21AGN-751 21 19.6 2.90 2.47 Standard
23AGN-751 23 21.4 3.45 2.91 Standard
25AGN-751 25 23.0 4.02 3.34 Standard
27AGN-751 27 24.9 4.69 4.28 Standard
Ordering InformationContents: Aortic Valve (1 unit per box)
RegentMechanical Heart Valve
Standard Cuff
Aortic Valves
Product Highlights Designed to deliver exceptional hemodynamics and performance while
maintaining low complication rates, structural integrity and durability
Single digit gradients, even in sizes as small as 19 mm1
Up to 84% orifice to annulus ratio
85 degree leaflet opening angle offers improved laminar flow and
reduces turbulence2-4
Supra-annular placement and low implant height
The FlexCuffis flanged and more pliable than the standard cuff
St. Jude Medical heart valves are MR Conditional5
1. St. Jude Medical, Inc. Pre-Market Approval Application Supplement. Regent Heart Valve. Washington, D.C.; U.S. Food and Drug Administration. 2002.
P810002S57.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.
J Heart Valve Dis.1999 Nov;8(6):687-96.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
Regent FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
18/60
Mechanical Heart Valves
RegentMechanical Heart Valve
Flex Cuff
Aortic Valves
Product Highlights Designed to deliver exceptional hemodynamics and performance while
maintaining low complication rates, structural integrity and durability
Single digit gradients, even in sizes as small as 19 mm1
Up to 84% orifice to annulus ratio
85 degree leaflet opening angle offers improved laminar flow and
reduces turbulence2-4
Supra-annular placement and low implant height
The FlexCuffis flanged and more pliable than the standard cuff
St. Jude Medical heart valves are MR Conditional5
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
Effective
Orifice Area6
(cm2) Cuff Style
19AGFN-756 19 17.8 2.39 1.84 FlexCuff
21AGFN-756 21 19.6 2.90 2.47 FlexCuff
23AGFN-756 23 21.4 3.45 2.91 FlexCuff
25AGFN-756 25 23.0 4.02 3.34 FlexCuff
27AGFN-756 27 24.9 4.69 4.28 FlexCuff
Ordering InformationContents: Aortic Valve (1 unit per box)
1. St. Jude Medical, Inc. Pre-Market Approval Application Supplement. Regent Heart Valve. Washington, D.C.; U.S. Food and Drug Administration. 2002.
P810002S57.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.
J Heart Valve Dis.1999 Nov;8(6):687-96.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
Regent FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
19/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
20/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
21/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
Effective
Orifice Area8
(cm2) Cuff Style
17AEHPJ-505 17 14.8 1.63 1.16 Expanded
19AEHPJ-505 19 16.7 2.06 1.51 Expanded
21AEHPJ-505 21 18.6 2.55 2.03 Expanded
23AEHPJ-505 23 20.4 3.09 2.59 Expanded
25AEHPJ-505 25 22.5 3.67 3.08 Expanded
27AEHPJ-505 27 24.2 4.41 3.73 Expanded
Ordering InformationContents: Aortic Valve (1 unit per box)
Masters HPMechanical Heart Valve
Expanded Cuff
Aortic Valves
Product Highlights Sewing cuff redesigned to facilitate supra-annular placement, allowing
for an increase in orifice size for a given tissue annulus diameter
Increased effective orifice area (EOA), lower pressure gradients,
and improved performance1-5
85 degree leaflet opening angle offers improved laminar flowand reduces turbulence1,2,6
Controlled torque rotation mechanism allows for easy rotation
and intraoperative adjustment
The expanded HP cuff has approximately 15% more cuff than the
standard HP cuff
St. Jude Medical heart valves are MR conditional7
1. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
2. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs2002;26(1):32-9.
3. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
4. St. Jude Medical MRI Safety Document.
5. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.
J Heart Valve Dis.1999 Nov;8(6):687-96.
6.Vitale N, Caldarera I, Muneretto C, et al. Italian Multicenter Study Group for the St. Jude Medical Hemodynamic Plus Aortic Valve Prosthesis.
Clinical evaluation of St. Jude Medical Hemodynamic Plus versus standard aortic valve prostheses: The Italian multicenter, prospective, randomized study.
J Thorac Cardiovasc Surg.2001 Oct;122(4):691-8.
7.Carrel T, Zingg U, Jenni R, et al. Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus.
Ann Thorac Surg.1996 May;61(5):1418-22.
8. Ismeno G, Renzulli A, De Feo M, et al. Standard versus Hemodynamic Plus 19-mm St. Jude Medical aortic valves. J Thorac Cardiovasc Surg. 2001
Apr;121(4):723-8.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
22/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
Effective
Orifice Area6
(cm2) Cuff Style
19AJ-501 19 14.8 1.63 1.16 Standard
21AJ-501 21 16.7 2.06 1.51 Standard
23AJ-501 23 18.6 2.55 2.03 Standard
25AJ-501 25 20.4 3.09 2.59 Standard
27AJ-501 27 22.5 3.67 3.08 Standard
29AJ-501 29 24.2 4.41 Not reported Standard
31AJ-501 31 26.1 5.18 Not reported Standard
Ordering Information
Contents: Aortic Valve (1 unit per box)
Masters Series Mechanical Heart Valve
Standard Cuff
Aortic Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
The expanded Masters aortic cuff has approximately 25% more cuff
than the standard cuff
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic
Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
M h i l H t V l
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
23/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
Effective
Orifice Area6
(cm2) Cuff Style
19AECJ-502 19 14.8 1.63 1.16 Expanded
21AECJ-502 21 16.7 2.06 1.51 Expanded
23AECJ-502 23 18.6 2.55 2.03 Expanded
25AECJ-502 25 20.4 3.09 2.59 Expanded
27AECJ-502 27 22.5 3.67 3.08 Expanded
29AECJ-502 29 24.2 4.41 Not reported Expanded
31AECJ-502 31 26.1 5.18 Not reported Expanded
Ordering Information
Contents: Aortic Valve (1 unit per box)
Masters Series Mechanical Heart Valve
Expanded Cuff
Aortic Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
The expanded Masters aortic cuff has approximately 25% more cuff
than the standard cuff
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic
Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
24/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue AnnulusDiameter
(mm)
Valve OrificeInner Diameter
(mm)
GeometricOrifice Area
(cm2)
EffectiveOrifice Area6
(cm2) Cuff Style
19ATJ-503 19 14.8 1.63 1.16 PTFE
21ATJ-503 21 16.7 2.06 1.51 PTFE
23ATJ-503 23 18.6 2.55 2.03 PTFE
25ATJ-503 25 20.4 3.09 2.59 PTFE
27ATJ-503 27 22.5 3.67 3.08 PTFE
29ATJ-503 29 24.2 4.41 Not reported PTFE
31ATJ-503 31 26.1 5.18 Not reported PTFE
Ordering InformationContents: Aortic Valve (1 unit per box)
Masters Series Mechanical Heart Valve
PTFE Cuff
Aortic Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic
Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
25/60
Mechanical Heart Valves
Model/Reorder
Number
Tissue Annulus
Diameter (mm)
Valve Orifice Inner
Diameter (mm)
Geometric Orifice
Area (cm2) Cuff Style
17MHPJ-505 17 14.8 1.63 Standard
19MHPJ-505 19 16.7 2.06 Standard
21MHPJ-505 21 18.6 2.55 Standard
23MHPJ-505 23 20.4 3.09 Standard
25MHPJ-505 25 22.5 3.67 Standard
27MHPJ-505 27 24.2 4.41 Standard
Ordering InformationContents: Mitral Valve (1 unit per box)
Masters HPMechanical Heart Valve
Standard Cuff
Mitral Valves
Product Highlights Sewing cuff redesigned to facilitate supra-annular placement, allowing
for an increase in orifice size for a given tissue annulus diameter
Increased geometric orifice area (GOA), lower pressure gradients,
and improved performance1,2
85 degree leaflet opening angle offers improved laminar flowand reduces turbulence1-3
Controlled torque rotation mechanism allows for easy rotation
and intraoperative adjustment
Minimizes interference with sub-valvular structures
St. Jude Medical heart valves are MR conditional4
1. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
2. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
3. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
4. St. Jude Medical MRI Safety Document.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
26/60
Mechanical Heart Valves
Model/ReorderNumber
Tissue AnnulusDiameter (mm)
Valve Orifice InnerDiameter (mm)
Geometric OrificeArea (cm2) Cuff Style
19MJ-501 19 14.8 1.63 Standard
21MJ-501 21 16.7 2.06 Standard
23MJ-501 23 18.6 2.55 Standard
25MJ-501 25 20.4 3.09 Standard
27MJ-501 27 22.5 3.67 Standard
29MJ-501 29 24.2 4.41 Standard31MJ-501 31 26.1 5.18 Standard
33MJ-501 33 26.1 5.18 Standard
35MJ-501 35 26.1 5.18 Standard
37MJ-501 37 26.1 5.18 Standard
Ordering InformationContents: Mitral Valve (1 unit per box)
Masters Series Mechanical Heart Valve
Standard Cuff
Mitral Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
27/60
c c
Model/Reorder
Number
Tissue Annulus
Diameter (mm)
Valve Orifice Inner
Diameter (mm)
Geometric Orifice
Area (cm2) Cuff Style
19MECJ-502 19 14.8 1.63 Expanded
21MECJ-502 21 16.7 2.06 Expanded
23MECJ-502 23 18.6 2.55 Expanded
25MECJ-502 25 20.4 3.09 Expanded
27MECJ-502 27 22.5 3.67 Expanded
29MECJ-502 29 24.2 4.41 Expanded
31MECJ-502 31 26.1 5.18 Expanded
33MECJ-502 33 26.1 5.18 Expanded
Ordering Information
Contents: Mitral Valve (1 unit per box)
Masters Series Mechanical Heart Valve
Expanded Cuff
Mitral Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
The expanded mitral cuff has approximately 25% more cuff than
the standard mitral cuff
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
28/60
Model/Reorder
Number
Tissue Annulus
Diameter (mm)
Valve Orifice Inner
Diameter (mm)
Geometric Orifice
Area (cm2) Cuff Style
19MTJ-503 19 14.8 1.63 PTFE
21MTJ-503 21 16.7 2.06 PTFE
23MTJ-503 23 18.6 2.55 PTFE
25MTJ-503 25 20.4 3.09 PTFE
27MTJ-503 27 22.5 3.67 PTFE
29MTJ-503 29 24.2 4.41 PTFE
31MTJ-503 31 26.1 5.18 PTFE
33MTJ-503 33 26.1 5.18 PTFE
Ordering Information
Contents: Mitral Valve (1 unit per box)
Masters Series Mechanical Heart Valve
PTFE Cuff
Mitral Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
The expanded PTFE cuf has approximately 16% more cuff than the
standard PTFE cuff
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
29/60
Model/Reorder
Number
Tissue Annulus
Diameter (mm)
Valve Orifice Inner
Diameter (mm)
Geometric Orifice
Area (cm2) Cuff Style
19METJ-504 19 14.8 1.63 Expanded PTFE
21METJ-504 21 16.7 2.06 Expanded PTFE
23METJ-504 23 18.6 2.55 Expanded PTFE
25METJ-504 25 20.4 3.09 Expanded PTFE
27METJ-504 27 22.5 3.67 Expanded PTFE
29METJ-504 29 24.2 4.41 Expanded PTFE
31METJ-504 31 26.1 5.18 Expanded PTFE
33METJ-504 33 26.1 5.18 Expanded PTFE
Ordering Information
Contents: Mitral Valve (1 unit per box)
Masters Series Mechanical Heart Valve
Expanded PTFE Cuff
Mitral Valves
Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability
and increased thromboresistance1
85 degree leaflet opening angle offers improved laminar flow
and reduces turbulence2-4
Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment
The expanded PTFE cuf has approximately 16% more cuff than the
standard PTFE cuff
St. Jude Medical heart valves are MR conditional5
1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Ann Thorac Surg.2005; 79:776-83.
2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.
J Eng Med1994: 208:63-72.
3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs
2002;26(1):32-9.
4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.
5. St. Jude Medical MRI Safety Document.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
30/60
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Graft Inner
Diameter
(mm)
Skirt Diameter
(mm) +/- 10%
(inflated)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
19VAVGJ-515 19 20 26 16.7 2.06
21VAVGJ-515 21 22 28 18.6 2.55
23VAVGJ-515 23 24 32 20.4 3.09
25VAVGJ-515 25 26 34 22.5 3.67
27VAVGJ-515 27 28 36 24.2 4.41
29VAVGJ-515 29 30 38 26.1 5.18
Ordering InformationContents: Aortic Valved Graft (1 unit per box)
Masters HPValved Graft
with Gelweave ValsalvaTechnology
Aortic Valved Grafts
Product Highlights Patented Valsalva design mimics natural anatomy and eases
anastomotic suturing1-3
Gelweave technology gelatin coating aids in tissue ingrowth4
Low porosity graft enables zero pre-clotting4
Expanded cuff designed to minimize potential for paravalvular leak Graft length is 10 cm minimum
St. Jude Medical heart valves are MR conditional5
1. De Paulis R, De Matteis GM, Nardi P, et al. A New Aortic Dacron Conduit for Surgical Treatment of Aortic Root Pathology. Ital Heart J.2000 Jul;1(7):457-63.
2. De Paulis R, Bassano C, Scaffa R, et al. Bentall Producures with a Novel Valved Conduit Incorporating Sinuses of Valsalva. Surg Technol Int.
2004;12:195-200.
3. De Paulis R, De Matteis GM, Nardi P, et al. One-year Appraisal of a New Aortic Root Conduit with Sinuses of Valsalva. J Thorac Cardiovasc Surg.
2002 Jan;123(1):33-9.
4. From Manufacturers Literature: Vascutek, Ltd.
5. St. Jude Medical MRI Safety Document.
Gelweave Valsalva is a trademark of Vascutek, Ltd.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
31/60
Model/Reorder
Number
Tissue Annulus
Diameter
(mm)
Graft Inner
Diameter
(mm)
Valve Orifice
Inner Diameter
(mm)
Geometric
Orifice Area
(cm2)
19CAVGJ-514-00 19 20 14.7 1.63
21CAVGJ-514-00 21 22 16.7 2.06
23CAVGJ-514-00 23 24 18.5 2.55
25CAVGJ-514-00 25 28 20.4 3.09
27CAVGJ-514-00 27 30 22.3 3.6729CAVGJ-514-00 29 32 24.1 4.41
31CAVGJ-514-00 31 34 26.0 5.18
33CAVGJ-514-00 33 34 26.0 5.18
Ordering InformationContents: Aortic Valved Graft (1 unit per box)
Masters Valved Graft
with HemashieldTechnology
Aortic Valved Grafts
Product Highlights Hemashield technology graft with collagen impregnation provides
uniform tissue ingrowth and biocompatibility1
Low porosity graft requires no pre-clotting1
No pleats at valve cuff allow for easy positioning and attachment
of coronary anastomosis
1
Graft length is 12 cm
St. Jude Medical heart valves are MR conditional2
1. From Manufacturers Literature: MAQUET Cardiovascular.
2. St. Jude Medical MRI Safety Document.
Hemashield is a registered trademark of Maquet Cardiovascular LLC.
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Mechanical Heart Valves
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
32/60
Ordering InformationContents: 7 Double-ended Aortic Sizers, 1 Valve Holder Handle and 1 Autoclave-able Tray with Cover (1 unit per box)
RegentMechanical Heart Valve Sizer SetAccessories
Product Highlights Designed to facilitate proper size selection of the Regent mechanical heart valve
in a supra-annular position
Sizes 17 mm 29 mm
The cylindrical end determines the appropriate size of the annulus
The corresponding Regent valve replica end is used to visualize placement
Malleable nitinol sizer and holder handle can be bent in any direction up to
90 degrees without degradation
Sizer and holder handle return to original straight shape during sterilization
Model/ReorderNumber Description
907 Sizer Set, Complete
905-HH Valve Holder Handle
AG-RHR Replacement Regent Valve Holder/Rotators, Sizes 17 mm29mm
LT100 Mechanical Valve Leaflet Tester
Rx Only
St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic
valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,
hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the
physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.
Regent ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
33/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
34/60
Valve Repair
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
35/60
Valve Repair
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
36/60
Model/ReorderNumber Ring Size
Fixed Dimension(mm) (A)
Ring InnerDimension (mm) (B)
Ring OuterDimension (mm) (C)
AFR-25 25 25 28.4 33.4
AFR-27 27 27 31.2 36.2
AFR-29 29 29 34.0 39.0
AFR-31 31 31 36.6 41.6
AFR-33 33 33 39.4 44.4
AFR-35 35 35 40.9 45.9
AFR-37 37 37 43.7 48.7
AFR-39 39 39 46.2 51.2
AFR-41 41 41 49.0 54.0
AFR-43 43 43 51.6 56.6
Ordering InformationContents: Flexible Adjustable Annuloplasty Ring (1 unit per box)
AttuneFlexible Adjustable Annuloplasty RingFlexible Ring
Product Highlights Fully flexible design allows dynamic movement of the annulus
Symmetrical and asymmetrical adjustability is designed to achieve ideal
leaflet coaptation and match each patients annulus
Adjustability after placement is designed to help eliminate residual
mitral regurgitation
Independent adjustability allows the annuloplasty to be localized to one side
Suitable for implant using open sternotomy, minimally invasive
and robotic approaches
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
Attune ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
37/60
Ordering InformationContents: Flexible Ring (1 unit per box)
TailorFlexible Annuloplasty RingFlexible Ring
Product Highlights Designed to maintain the size of a repaired mitral or tricuspid annulus while
sustaining physiologic movement
Anterior and posterior support allows dynamic annular motion during the
cardiac cycle
Flexible design aids cardiac output and left ventricular function, supporting
optimal hemodynamics1-3
Large target area eases suturing
Suitable for implant using open sternotomy, minimally invasive
and robotic approaches
Model/Reorder
Number Ring Size
Inside
Dimension (mm) (B)
Outside
Dimension (mm) (C)
Intertrigonal
Dimension (mm) (A)
TARP-25 25 28.4 34.4 25
TARP-27 27 31.2 37.2 27
TARP-29 29 34.0 40.0 29
TARP-31 31 36.6 42.6 31
TARP-33 33 39.4 45.4 33
TARP-35 35 40.9 47.9 35
1. Yamaura Y, Yoshikawa J, Yoshida K, et al. Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane
transesophageal echocardiography: Comparison between flexible and rigid annuloplasty rings. J Heart Valve Dis.1995;4(6)61822.
2. Kunzelman K, Reimink S, Cochran P. Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model. J Heart Valve Dis.
1998;7(1)108.
3. David T, Armstrong S, Sun Z. Left ventricular function after mitral valve surgery. J Heart Valve Dis.1995;4(Supl) S17580.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
Tailor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
38/60
Ordering InformationContents: Flexible Band (1 unit per box)
TailorFlexible Annuloplasty BandFlexible Band
Product Highlights Band offers simple alternative and time-saving simplicity to flexible rings
Posterior support allows dynamic annular motion
Flexible design aids cardiac output and left ventricular function, supporting
optimal hemodynamics1-3
Large target area eases suturing
Suitable for implant using open sternotomy, minimally invasive
and robotic approaches
Model/ReorderNumber Ring Size
InsideDimension (mm) (B)
OutsideDimension (mm) (C)
IntertrigonalDimension (mm) (A)
TAB-25 25 28.4 34.4 25
TAB-27 27 31.2 37.2 27
TAB-29 29 34.0 40.0 29
TAB-31 31 36.6 42.6 31
TAB-33 33 39.4 45.4 33
TAB-35 35 40.9 47.9 35
1. Yamaura Y, Yoshikawa J, Yoshida K, et al. Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane
transesophageal echocardiography: Comparison between flexible and rigid annuloplasty rings. J Heart Valve Dis.1995;4(6)61822.
2. Kunzelman K, Reimink S, Cochran P. Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model. J Heart Valve Dis.
1998;7(1)108.
3. David T, Armstrong S, Sun Z. Left ventricular function after mitral valve surgery. J Heart Valve Dis.1995;4(Supl) S17580.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
Tailor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
39/60
A
A
B
C
Internal 2-DOrifice Area
Ordering InformationContents: Rigid Saddle Ring (1 unit per box)
SJMRigid Saddle RingRigid / Semi-Rigid Rings
Product Highlights Designed to restore the shape of a healthy mitral annulus1
Titanium core maintains the anatomical shape and provides annular remodeling
Saddle shape contributes to efficient distribution of leaflet stress and chordal tension
which may increase repair durability1-4
EZ Suture Cuff is supported by a unique triangular core for a larger suture target
Model/Reorder
Number Ring Size
CommisureDimension
(mm) (A)
InsideDimension
(mm) (B)
OutsideDimension
(mm) (C)
A-PDimension
(mm) (D)
Internal 2-DOrifice Area
(mm2)
RSAR-24 24 24 22 30 13.6 227
RSAR-26 26 26 24 32 15.1 276
RSAR-28 28 28 26 34 16.2 331
RSAR-30 30 30 28 26 17.9 387
RSAR-32 32 32 30 38 19.2 450
RSAR-34 34 34 32 40 20.6 511
1. Jimenez JH, Soerensen DD, He Z, et al. Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: an in vitro study.
Ann Biomed Eng.2003;31(10):1171-81.
2. Salgo IS, Gorman JH 3rd, Gorman RC, et al. Effect of annular shape on leaflet curvature in reducing mitral leaflet stress. Circulation.2002;106(6):711-7.
3. Jimenez JH, Liou SW, Padala M, et al. A saddle-shaped annulus reduces systolic strain on the central region of the mitral valve anterior leaflet.
J Thorac Cardiovasc Surg.2007;134(6):1562-8.
4. Gorman JH 3rd, Jackson BM, Enomoto Y, et al. The effect of regional ischemia on mitral valve annular saddle shape. Ann Thorac Surg. 2004;77(2):544-8.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
SJM S i S i Ri id A l l t Ri
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
40/60
Internal 2-D
Orifice Area
B
C
A
Ordering InformationContents: Semi-Rigid Ring (1 unit per box)
SJMSguin Semi-Rigid Annuloplasty RingRigid / Semi-Rigid Rings
Product Highlights Designed to aid cardiac output and left ventricular function1
Semi-rigid, three-dimensional posterior section is designed to preserve the
physiologic movement of the valve annulus1
Increased rigidity of the anterior section of the ring promotes annular remodeling 1
The solid, one piece inner core resists needle penetration, reducing the potential
for suturing through the core
Model/Reorder
Number Ring Size
CommisureDimension
(mm) (A)
InsideDimension
(mm) (B)
OutsideDimension
(mm) (C)
Internal 2-DOrifice Area
(mm2)
SARP-24 24 24 22 29 284
SARP-26 26 26 24 31 334
SARP-28 28 28 27 34 404
SARP-30 30 30 28 35 463
SARP-32 32 32 30 37 541
SARP-34 34 34 34 41 602
SARP-36 36 36 36 43 630
SARP-38 38 38 37 45 735
SARP-40 40 40 39 46 815
1. Sguin J, Demaria R, Chaptal PA. Preservation of three-dimensional annular movement with the SJM-Seguin mitral annuloplasty ring. J Heart Valve Dis.
1996;5(6):641-46.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
SJM P i a dial Pat h
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
41/60
Ordering InformationContents: Pericardial Patch (1 unit per box)
SJMPericardial Patch
with EnCapAC TechnologyPericardial Patch
Product Highlights Flexible and durable to provide enhanced biocompatibility and lasting performance1-3
Bovine pericardium provides improved handling and suturability compared
with synthetic patches4
Anti-calcification treatment enhances tissue healing, biocompatibility and long-term
tissue stability1*
Thinner patch available to accommodate pediatric applications5
Soft, pliable tissue conforms to the anatomy and easily sutures into place
Ready-to use, rinseless preparation saves time during procedures
*There is no clinical data currently available which evaluates the long-term impact of anticalcification treatment in humans.
1. Frater RWM, Seifter E, Liao K, et al. Anticalcification, proendothelial, and anti-inflammatory effect of post-aldehyde polyol treatment of bioprosthetic material.
In: Gabbay S, Wheatley DJ (eds.). Advances in Anticalcific and Antidegenerative Treatment of Heart Valve Bioprostheses.Austin, TX: Silent Partners Inc;
1997:105-14.
2. Frater RWM, Liao K, Seifter E. Stentless chordally supported mitral bioprosthetic valve. In: Gabbay S, Frater RWM (eds.) New Horizons and the Future of Heart
Valve Bioprostheses.Austin, TX: Silent Partners Inc; 1994:103-19.
3. Hoffman D, Gong G, Liao K, et al. Spontaneous host endothelial growth on bioprostheses. Circulation.1992;86[suppl II]:II-75-II-79.
4. Crawford FA Jr, Sade RM, Spinale F. Bovine pericardium for correction of congenital heart defects. Ann Thorac Surg.1986;41(6):602-5.
5. Hopkins, et. al. Surgical Patch Closure of Atrial Septal Defects. Ann Thorac Surg.2001;77-2144-50.
EnCap is a trademark of Glycar, Inc.
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Model/Reorder
Number
Patch Size
(cm)
Nominal Thickness
(mm)
C0205 2 x 5 0.20 0.40
C0405 4 x 5 0.150.25
C0510 5 x 10 0.20 0.40
C0914 9 x 14 0.20 0.40
Valve Repair
Tailor Annuloplasty Ring Sizer Set
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
42/60
Tailor Annuloplasty Ring Sizer SetAccessories
Product Highlights Designed to facilitate proper size selection of the Tailor ring and band
and Attunering
Sizes 25 mm 35 mm
Malleable nitinol sizer and holder handle can be bent in any direction up to
90 degrees without degradation
Ordering InformationContents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover
Model/ReorderNumber Description
TAR-505 Tailor Flexible Ring Set, Complete
HH-05 Replacement Holder Handle
EX-05 Replacement Extension Handle
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
Tailor Attune ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
SJM Rigid Saddle Ring Sizer Set
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
43/60
Ordering InformationContents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover
SJM Rigid Saddle Ring Sizer SetAccessories
Product Highlights Designed to facilitate proper size selection of the SJM Rigid Saddle annuloplasty ring
Sizes 24 mm 34 mm
Malleable nitinol sizer and holder handle can be bent in any direction up to
90 degrees without degradation
Model/ReorderNumber Description
RSAR-507A SJM Rigid Saddle Ring Sizer Set, Compete
HH-05 Replacement Holder Handle
EX-05 Replacement Extension Handle
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential
adverse events, and directions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Valve Repair
SJM Sguin Semi-Rigid Annuloplasty Ring
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
44/60
SJM Sguin Semi Rigid Annuloplasty Ring
Sizer SetAccessories
Product Highlights Designed to facilitate proper size selection for the SJM Seguin annuloplasty ring
Sizes 24 mm 40 mm
Malleable nitinol sizer and holder handle can be bent in any direction up to
90 degrees without degradation
Ordering InformationContents: 9 Mitral Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover
Model/ReorderNumber Description
SAR-501 SJM Sguin Semi-Rigid Ring Sizer Set, Complete
HH-05 Replacement Holder Handle
EX-05 Replacement Extension Handle
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
45/60
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
46/60
Cardiac Ablation
Cardiac Ablation
Cardiac Ablation Table of Contents
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
47/60
EpicorCardiac Ablation System
Epicor
Ablation Control System (ACS)...................................................................................................CA2
EpicorLP Cardiac Ablation System
UltraCinchLP Ablation Device .............................................................................................................CA3
UltraWandLP Handheld Ablation Device ..............................................................................................CA4
LP Connecting Cable..............................................................................................................................CA5
LP Positioning and Sizing (LP PAS) System ............................................................................................CA6
LP Oblique Introducer ............................................................................................................................CA7
Universal IV Set .....................................................................................................................................CA8
Cardiac Ablation
EpicorAblation Control System (ACS)
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
48/60
Ordering InformationContents: Ablation Control System (1 unit per box)
Epicor Cardiac Ablation System
Product Highlights Utilizes high intensity focused ultrasound (HIFU) to surgically ablate cardiac tissue
concomitant with cardiac surgery
Designed to create lesions entirely epicardially while the patient is off-pump
Simple one-button control
Intuitive user display provides real-time information on ablation cycle progress
and system performance
Power, frequency, and temperature display and monitoring
Integrated safety features and real-time help screens
Scalable architecture for ongoing system and software upgrades
Model/Reorder
Number
Power
Configuration
ACS-US-2 100-120 V, 60 Hz, 1000 VA
Rx Only
Please review the Instructions for Use prior to using these devices for Use for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
Epicor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered
Cardiac Ablation
UltraCinchLP Ablation Device
-
8/13/2019 2011 CardiacSurgery Catalog US 062811
49/60
Ordering InformationContents: UltraCinch LP Ablation Device (1 unit per box)
EpicorLP Cardiac Ablation System
Product Highlights An array of high intensity focused ultrasound (HIFU) emitting transducers creates a
contiguous, circular lesion in a single step, entirely epicardially and off-pump
A flexible transducer cell array, low transducer cell profile and a tapered distal end
make it equally suited for use in open- or closed-chest procedures
Integrated tensioning sutures prevent device migration and keep energy focused
on targeted tissue
Single-plane energy delivery designed to reduce the risk of collateral damage Multiple sizes accommodate varying anatomy
Ablates through fat, eliminating the need for dissection
Model/Reorder
Number
Size
(cells)
UC-LP-7 7
UC-LP-8 8
UC-LP-9 9
UC-LP-10 10
UC-LP-11 11
UC-LP-12 12
UC-LP-13 13
Rx Only
Please review the Instructions for Use prior to using these devices for a complete listing of indications,
contraindications, warnings, precautions, potential adverse events, and directions for use.
UltraCinch Epicor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are
-