    Cardiac Surgery

    U.S. Product Catalog

    May 2011

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    2/60

    Table of Contents

    Tissue Heart Valves

    Aortic Supra-Annular Stented Valves

    TrifectaStented Tissue Valve with Linx AC Technology ........................................................................TH2

    EpicSupra Stented Tissue Valve with LinxAC Technology ...................................................................TH3

    Biocor Supra Stented Tissue Valve .......................................................................................................TH4

    Aortic Stented Valves

    EpicStented Tissue Valve with LinxAC Technology .............................................................................TH5

    Biocor Stented Tissue Valve .................................................................................................................TH6

    Mitral Stented ValvesEpicStented Tissue Valve with LinxAC Technology .............................................................................TH7

    Biocor Stented Tissue Valve .................................................................................................................TH8

    Accessories

    Trifecta Valve Sizer Set ........................................................................................................................TH9

    Bioprosthetic Heart Valve Sizer Set .......................................................................................................TH10

    Mechanical Heart Valves

    Aortic Valves

    Regent Mechanical Heart Valve ...........................................................................................................MH2

    Masters HPMechanical Heart Valve ....................................................................................................MH4

    Masters Series Mechanical Heart Valve .................................................................................................MH7

    Mitral Valves

    Masters HPMechanical Heart Valve ..................................................................................................MH10 Masters Series Mechanical Heart Valve ...............................................................................................MH11

    Aortic Valved Grafts

    Masters HPValved Graft with Gelweave ValsalvaTechnology .............................................................MH15

    Masters Valved Graft with Hemashield Technology.............................................................................MH16

    Accessories

    RegentMechanical Heart Valve Sizer Set ..........................................................................................MH17

    SJMMechanical Heart Valve Sizer Set ...............................................................................................MH18

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    3/60

    Table of Contents

    Valve Repair

    Flexible Rings and Band

    AttuneFlexible Adjustable Annuloplasty Ring .......................................................................................VR2

    TailorFlexible Annuloplasty Ring ..........................................................................................................VR3

    TailorFlexible Annuloplasty Band .........................................................................................................VR4

    Rigid / Semi-Rigid Rings

    SJMRigid Saddle Ring ........................................................................................................................VR5

    SJMSguin Semi-Rigid Annuloplasty Ring ...........................................................................................VR6

    Pericardial Patch SJMPericardial Patch with EnCapAC Technology ..............................................................................VR7

    Accessories

    TailorAnnuloplasty Ring Sizer Set ........................................................................................................VR8

    SJMRigid Saddle Ring Sizer Set ..........................................................................................................VR9

    SJMSguin Semi-Rigid Annuloplasty Ring Sizer Set ...........................................................................VR10

    Tailorand AttuneRing Robotic Sizer Set...........................................................................................VR11

    Cardiac Ablation

    EpicorCardiac Ablation System

    EpicorAblation Control System (ACS)...................................................................................................CA2

    EpicorLP Cardiac Ablation System

    UltraCinchLP Ablation Device .............................................................................................................CA3

    UltraWandLP Handheld Ablation Device ..............................................................................................CA4 LP Connecting Cable..............................................................................................................................CA5

    LP Positioning and Sizing (LP PAS) System ............................................................................................CA6

    LP Oblique Introducer ............................................................................................................................CA7

    Universal IV Set .....................................................................................................................................CA8

    Cardiac Surgery Catalog Reorder Number Index

    Terms of Sale

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    4/60

    Tissue Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    5/60

    Tissue Heart Valves Table of Contents

    Tissue Heart Valves

    Aortic Supra-Annular Stented Valves

    TrifectaStented Tissue Valve with Linx AC Technology ........................................................................TH2

    EpicSupra Stented Tissue Valve with LinxAC Technology ...................................................................TH3

    Biocor Supra Stented Tissue Valve .......................................................................................................TH4

    Aortic Stented Valves

    EpicStented Tissue Valve with LinxAC Technology .............................................................................TH5

    Biocor Stented Tissue Valve .................................................................................................................TH6

    Mitral Stented ValvesEpicStented Tissue Valve with LinxAC Technology .............................................................................TH7

    Biocor Stented Tissue Valve .................................................................................................................TH8

    Accessories

    Trifecta Valve Sizer Set ........................................................................................................................TH9

    Bioprosthetic Heart Valve Sizer Set .......................................................................................................TH10

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    6/60

    Total Height AorticProtrusion

    Tissue Annulus Diameter

    Cuff Outer Diameter

    1. St. Jude Medical. Trifecta Valve, Pre-Market Approval Application Summary of Safety and Effectiveness Data, P100029, 2011.

    2. Data on File, St. Jude Medical.

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    Rx Only

    Brief Summary:Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions,

    potential adverse events and directions for use.

    Indications:The Trifecta Valve is indicated as a replacement for a diseased, damaged, or malfunctioning native or prosthetic aor tic heart valve. Adverse events

    potentially associated with the use of bioprosthetic hear t valves include: angina, cardiac arrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia,hemorrhage, leak (transvalvular or perivalvular), myocardial infarction, nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or

    positioning, or other), prosthesis regurgitation, stroke, structural deterioration (calcification, leaflet tear, perforation, or other), thromboembolism and valve

    thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term low dose aspirin, unless

    contraindicated, is recommended for all patients with bioprosthetic valves. Long-term anticoagulant therapy, unless contraindicated, is recommended for all

    patients with bioprosthetic valves who have risk factors for thromboembolism. Please see the Instructions for Use (IFU) for a full description of indications,

    contraindications, side effects, precautions, warnings and Instructions for Use.

    Trifecta Linx ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    TrifectaStented Tissue Valve

    with LinxAC TechnologyAortic Supra-Annular Stented Valves

    Product Highlights Exceptional hemodynamic performance1

    Exterior-mounted pericardial leaflets with unique suture attachment allows for

    maximum leaflet excursion and large EOAs2

    Designed to provide excellent durability with the pericardial-covered stent for

    tissue-to-tissue contact to reduce the risk of abrasion

    Includes LinxAC Technology, which is designed to improve long-term performance

    and valve durability*

    Designed to maintain structural integrity with a high-strength, fatigue-resistant,

    titanium alloy stent2

    Short 2 x 10-second rinse time

    Ordering InformationContents: Aortic Supra-Annular Stented Tissue Valve (1 unit per box)

    Model/Reorder

    Number

    Valve Size

    (mm)

    Tissue Annulus

    Diameter

    (mm)

    Cuff

    Outer

    Diameter (mm)

    Aortic

    Protrusion

    (mm)

    Total

    Height

    (mm)

    TF-19A 19 19 24 12 15

    TF-21A 21 21 26 13 16

    TF-23A 23 23 28 13 17

    TF-25A 25 25 31 14 18

    TF-27A 27 27 33 15 19

    TF-29A 29 29 35 16 20

    Tissue Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    7/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    8/60

    InternalDiameter

    AorticProtrusion

    TotalHeight

    TissueAnnulusDiameter

    Tissue Heart Valves

    Ordering InformationContents: Aortic Supra-Annular Stented Tissue Valve (1 unit per box)

    BiocorSupra Stented Tissue ValveAortic Supra-Annular Stented Valves

    Product Highlights Provides a larger stent-to-annulus ratio than Biocor Aortic Valve

    Delivers proven 20-year durability results1,2

    Three separate porcine leaflets are matched to optimize leaflet coaptation

    and reduce stress

    The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue

    interface to reduce the risk of abrasion FlexFitstent reduces leaflet stress, adapts easily to annulus to enhance knot

    positioning, and returns stent posts to original shape after deflection

    Low profile design provides optimal coronary ostia clearance

    Short 2 x 10 second rinse time

    Model/Reorder

    Number

    Valve

    Size

    (mm)

    Tissue

    Annulus

    Diameter (mm)

    Internal

    Diameter

    (mm)

    Aortic

    Protrusion

    (mm)

    Total

    Height

    (mm)

    BSP100-19 19 19 19 11 14

    BSP100-21 21 21 21 11 15

    BSP100-23 23 23 23 13 16

    BSP100-25 25 25 25 13 17

    BSP100-27 27 27 27 14 19

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.

    2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.

    2008;86(4):1204-1210.

    Rx Only

    St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic

    anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,

    suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and

    valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/

    or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.

    Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.

    Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    9/60

    InternalDiameter

    AorticProtrusionTotal

    Height

    TissueAnnulusDiameter

    Ordering InformationContents: Aortic Stented Tissue Valve (1 unit per box)

    EpicStented Tissue Valve

    with LinxAC TechnologyAortic Stented Valves

    Product Highlights Identical in design to the Biocorstented tissue valve which delivers proven

    20 year durability results1

    Includes Linx AC Technology which is designed to improve long-term performance

    and valve durability*

    Three separate porcine leaflets are matched to optimize leaflet coaptation andreduce stress

    The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue

    interface to reduce the risk of abrasion

    FlexFitstent reduces leaflet stress, adapts easily to annulus to enhance knot

    positioning, and returns stent posts to original shape after deflection

    Low profile design provides optimal coronary ostia clearance

    Short 2 x 10 second rinse time

    Tissue Heart Valves

    Model/Reorder

    Number

    Valve

    Size

    (mm)

    Tissue

    Annulus

    Diameter (mm)

    Internal

    Diameter

    (mm)

    Aortic

    Protrusion

    (mm)

    Total

    Height

    (mm)

    E100-21A-00 21 21 19 9 14

    E100-23A-00 23 23 21 9 15

    E100-25A-00 25 25 23 10 16

    E100-27A-00 27 27 25 11 17

    E100-29A-00 29 29 27 12 19

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.

    Rx Only

    St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic

    anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,

    suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and

    valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/

    or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.

    Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.

    Epic Linx Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    10/60

    InternalDiameter

    AorticProtrusionTotal

    Height

    TissueAnnulusDiameter

    Tissue Heart Valves

    Ordering InformationContents: Aortic Stented Tissue Valve (1 unit per box)

    BiocorStented Tissue ValveAortic Stented Valves

    Product Highlights Delivers proven 20 year durability results1,2

    Three separate porcine leaflets are matched to optimize leaflet coaptation

    and reduce stress

    The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue

    interface to reduce the risk of abrasion

    FlexFit

    stent reduces leaflet stress, adapts easily to annulus to enhance knotpositioning, and returns stent posts to original shape after deflection

    Low profile design provides optimal coronary ostia clearance

    Short 2 x 10 second rinse time

    Model/Reorder

    Number

    Valve

    Size

    (mm)

    Tissue

    Annulus

    Diameter (mm)

    Internal

    Diameter

    (mm)

    Aortic

    Protrusion

    (mm)

    Total

    Height

    (mm)

    B100-21A-00 21 21 19 9 14

    B100-23A-00 23 23 21 9 15

    B100-25A-00 25 25 23 10 16

    B100-27A-00 27 27 25 11 17

    B100-29A-00 29 29 27 12 19

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.

    2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.

    2008;86(4):1204-1210.

    Rx Only

    St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic

    anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,

    suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and

    valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/

    or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.

    Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.

    Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    11/60

    InternalDiameter

    VentricularProtrusion

    TotalHeight

    TissueAnnulusDiameter

    Tissue Heart Valves

    Ordering InformationContents: Mitral Stented Tissue Valve (1 unit per box)

    EpicStented Tissue Valve

    with LinxAC Technology

    Mitral Stented Valves

    Product Highlights Identical in design to the Biocorstented tissue valve which delivers proven

    20 year durability results1,2

    Includes Linx AC Technology which is designed to improve long-term performance and

    valve durability*

    Three separate porcine leaflets are matched to optimize leaflet coaptation and reduce stress

    The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue interface

    to reduce the risk of abrasion

    FlexFitmitral valve holder provides stent deflection (ratcheting), which reduces the potential

    for suture looping and maximizes visibility and access to the valve cuff

    Low combined valve and holder height facilitates minimally invasive

    surgical procedures

    Low profile design reduces the risk of LV outflow tract obstruction

    FlexFit stent reduces leaflet stress, adapts easily to annulus to enhance knot positioning,

    and returns stent posts to original shape after deflection

    Short 2 x 10 second rinse time

    Model/Reorder

    Number

    Valve

    Size (mm)

    Tissue Annulus

    Diameter (mm)

    Internal

    Diameter (mm)

    Ventricle

    Protrusion (mm)

    Total

    Height (mm)

    E100-25M-00 25 25 23 9 16

    E100-27M-00 27 27 25 9 17

    E100-29M-00 29 29 27 10 19

    E100-31M-00 31 31 29 10 20

    E100-33M-00 33 33 31 11 20

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.

    2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.

    2008;86(4):1204-1210.

    Rx Only

    St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic

    anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,

    suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and

    valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/

    or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.

    Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.

    Epic Linx Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    12/60

    InternalDiameter

    VentricularProtrusion

    TotalHeight

    TissueAnnulusDiameter

    Tissue Heart Valves

    Ordering InformationContents: Mitral Stented Tissue Valve (1 unit per box)

    BiocorStented Tissue ValveMitral Stented Valves

    Product Highlights Delivers proven 20-year durability results1,2

    Three separate porcine leaflets are matched to optimize leaflet coaptation and

    reduce stress

    The outflow edge is covered with a pericardial shield, providing a tissue-to-tissue

    interface to reduce the risk of abrasion

    FlexFit

    mitral valve holder provides stent deflection (ratcheting), which reducesthe potential for suture looping and maximizes visibility and access to the valve cuff

    Low combined valve and holder height facilitates minimally invasive

    surgical procedures

    Low profile design reduces the risk of LV outflow tract obstruction

    FlexFit stent reduces leaflet stress, adapts easily to annulus to enhance knot

    positioning, and returns stent posts to original shape after deflection

    Short 2 x 10 second rinse time

    Model/Reorder

    Number

    Valve

    Size

    (mm)

    Tissue

    Annulus

    Diameter (mm)

    Internal

    Diameter

    (mm)

    Ventricle

    Protrusion

    (mm)

    Total

    Height

    (mm)

    B100-25M-00 25 25 23 9 16

    B100-27M-00 27 27 25 9 17

    B100-29M-00 29 29 27 10 19

    B100-31M-00 31 31 29 10 20

    B100-33M-00 33 33 31 11 20

    *There is no clinical data currently available that evaluates the long-term impact of anticalcification tissue treatment in humans.

    1. Mykn PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac and Cardiovasc Surg.2009;137(1):76-81.

    2. Eichinger WB, Hettich IM, Ruzicka DJ, et al. Twenty-year experience with St. Jude medical Biocor bioprosthesis in the aortic position. Ann Thorac Surg.

    2008;86(4):1204-1210.

    Rx Only

    St. Jude Medical Stented Tissue Valves are indicated for use as a replacement for malfunctioning native or prosthetic aortic and/or mitral valves. Adverseevents potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, endocarditis, heart failure, hemolysis, hemolytic

    anemia, hemorrhage (anticoagulant/antiplatelet-related), leak (transvalvular or paravalvular), myocardial infarction, nonstructural dysfunction (e.g., pannus,

    suture, inappropriate sizing, or other), prosthesis regurgitation, stroke, structural deterioration (e.g., calcification, leaflet tear, or other), thromboembolism and

    valve thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term anticoagulation and/

    or anti-platelet therapy should be considered in patients with dilated left atrium, a history of thrombotic events or a cardiac rhythm of atrial fibrillation or flutter.

    Please see the Instructions for Use (IFU) for a full description of indications, contraindications, side effects, precautions, warnings and Instructions for Use.

    Biocor FlexFit ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    13/60

    Tissue Heart Valves

    TrifectaValve Sizer SetAccessories

    Product Highlights Designed to facilitate proper size selection of the Trifecta Tissue Valve

    Sizes 19 mm 29 mm

    The cylindrical end determines the appropriate size of the annulus

    The corresponding valve replica end is used to visualize supra-annular placement

    Features click-in handle for quick attachment to valve holder

    Malleable Nitinol sizer and handle can be bent in any direction (up to 90 degrees)

    without degradation

    Sizer and holder handle return to original, straight shape during sterilization

    Model/Reorder

    Number Description

    TF2000 Trifecta Valve Sizer Set, Complete

    UT2000 Flexible Holder Handle

    UT2000-R Rigid Holder Handle

    EX2000-R Rigid Extension Handle

    Ordering InformationContents: 6 Double-ended Aortic Sizers, 1 Valve Holder Handle and 1 Autoclavable Tray with Cover (1 unit per box)

    Rx Only

    Brief Summary:Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions,

    potential adverse events and directions for use.

    Indications:The Trifecta Valve is indicated as a replacement for a diseased, damaged, or malfunctioning native or prosthetic aor tic heart valve. Adverse events

    potentially associated with the use of bioprosthetic hear t valves include: angina, cardiac arrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia,hemorrhage, leak (transvalvular or perivalvular), myocardial infarction, nonstructural dysfunction (entrapment by pannus or suture, inappropriate sizing or

    positioning, or other), prosthesis regurgitation, stroke, structural deterioration (calcification, leaflet tear, perforation, or other), thromboembolism and valve

    thrombosis. It is possible that these complications could lead to reoperation, explantation, permanent disability or death. Long-term low dose aspirin, unless

    contraindicated, is recommended for all patients with bioprosthetic valves. Long-term anticoagulant therapy, unless contraindicated, is recommended for all

    patients with bioprosthetic valves who have risk factors for thromboembolism. Please see the Instructions for Use (IFU) for a full description of indications,

    contraindications, side effects, precautions, warnings and Instructions for Use.

    Trifecta ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    14/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    15/60

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    16/60

    Mechanical Heart Valves Table of Contents

    Mechanical Heart Valves

    Aortic Valves

    Regent Mechanical Heart Valve ...........................................................................................................MH2

    Masters HPMechanical Heart Valve ....................................................................................................MH4

    Masters Series Mechanical Heart Valve .................................................................................................MH7

    Mitral Valves

    Masters HPMechanical Heart Valve ..................................................................................................MH10

    Masters Series Mechanical Heart Valve ...............................................................................................MH11

    Aortic Valved Grafts

    Masters HPValved Graft with Gelweave ValsalvaTechnology .............................................................MH15

    Masters Valved Graft with Hemashield Technology.............................................................................MH16

    Accessories

    RegentMechanical Heart Valve Sizer Set ..........................................................................................MH17

    SJMMechanical Heart Valve Sizer Set ...............................................................................................MH18

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    17/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    Effective

    Orifice Area6

    (cm2) Cuff Style

    19AGN-751 19 17.8 2.39 1.84 Standard

    21AGN-751 21 19.6 2.90 2.47 Standard

    23AGN-751 23 21.4 3.45 2.91 Standard

    25AGN-751 25 23.0 4.02 3.34 Standard

    27AGN-751 27 24.9 4.69 4.28 Standard

    Ordering InformationContents: Aortic Valve (1 unit per box)

    RegentMechanical Heart Valve

    Standard Cuff

    Aortic Valves

    Product Highlights Designed to deliver exceptional hemodynamics and performance while

    maintaining low complication rates, structural integrity and durability

    Single digit gradients, even in sizes as small as 19 mm1

    Up to 84% orifice to annulus ratio

    85 degree leaflet opening angle offers improved laminar flow and

    reduces turbulence2-4

    Supra-annular placement and low implant height

    The FlexCuffis flanged and more pliable than the standard cuff

    St. Jude Medical heart valves are MR Conditional5

    1. St. Jude Medical, Inc. Pre-Market Approval Application Supplement. Regent Heart Valve. Washington, D.C.; U.S. Food and Drug Administration. 2002.

    P810002S57.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.

    J Heart Valve Dis.1999 Nov;8(6):687-96.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    Regent FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    18/60

    Mechanical Heart Valves

    RegentMechanical Heart Valve

    Flex Cuff

    Aortic Valves

    Product Highlights Designed to deliver exceptional hemodynamics and performance while

    maintaining low complication rates, structural integrity and durability

    Single digit gradients, even in sizes as small as 19 mm1

    Up to 84% orifice to annulus ratio

    85 degree leaflet opening angle offers improved laminar flow and

    reduces turbulence2-4

    Supra-annular placement and low implant height

    The FlexCuffis flanged and more pliable than the standard cuff

    St. Jude Medical heart valves are MR Conditional5

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    Effective

    Orifice Area6

    (cm2) Cuff Style

    19AGFN-756 19 17.8 2.39 1.84 FlexCuff

    21AGFN-756 21 19.6 2.90 2.47 FlexCuff

    23AGFN-756 23 21.4 3.45 2.91 FlexCuff

    25AGFN-756 25 23.0 4.02 3.34 FlexCuff

    27AGFN-756 27 24.9 4.69 4.28 FlexCuff

    Ordering InformationContents: Aortic Valve (1 unit per box)

    1. St. Jude Medical, Inc. Pre-Market Approval Application Supplement. Regent Heart Valve. Washington, D.C.; U.S. Food and Drug Administration. 2002.

    P810002S57.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.

    J Heart Valve Dis.1999 Nov;8(6):687-96.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    Regent FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    19/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    20/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    21/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    Effective

    Orifice Area8

    (cm2) Cuff Style

    17AEHPJ-505 17 14.8 1.63 1.16 Expanded

    19AEHPJ-505 19 16.7 2.06 1.51 Expanded

    21AEHPJ-505 21 18.6 2.55 2.03 Expanded

    23AEHPJ-505 23 20.4 3.09 2.59 Expanded

    25AEHPJ-505 25 22.5 3.67 3.08 Expanded

    27AEHPJ-505 27 24.2 4.41 3.73 Expanded

    Ordering InformationContents: Aortic Valve (1 unit per box)

    Masters HPMechanical Heart Valve

    Expanded Cuff

    Aortic Valves

    Product Highlights Sewing cuff redesigned to facilitate supra-annular placement, allowing

    for an increase in orifice size for a given tissue annulus diameter

    Increased effective orifice area (EOA), lower pressure gradients,

    and improved performance1-5

    85 degree leaflet opening angle offers improved laminar flowand reduces turbulence1,2,6

    Controlled torque rotation mechanism allows for easy rotation

    and intraoperative adjustment

    The expanded HP cuff has approximately 15% more cuff than the

    standard HP cuff

    St. Jude Medical heart valves are MR conditional7

    1. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    2. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs2002;26(1):32-9.

    3. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    4. St. Jude Medical MRI Safety Document.

    5. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic Performance.

    J Heart Valve Dis.1999 Nov;8(6):687-96.

    6.Vitale N, Caldarera I, Muneretto C, et al. Italian Multicenter Study Group for the St. Jude Medical Hemodynamic Plus Aortic Valve Prosthesis.

    Clinical evaluation of St. Jude Medical Hemodynamic Plus versus standard aortic valve prostheses: The Italian multicenter, prospective, randomized study.

    J Thorac Cardiovasc Surg.2001 Oct;122(4):691-8.

    7.Carrel T, Zingg U, Jenni R, et al. Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus.

    Ann Thorac Surg.1996 May;61(5):1418-22.

    8. Ismeno G, Renzulli A, De Feo M, et al. Standard versus Hemodynamic Plus 19-mm St. Jude Medical aortic valves. J Thorac Cardiovasc Surg. 2001

    Apr;121(4):723-8.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    HP FlexCuff ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    22/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    Effective

    Orifice Area6

    (cm2) Cuff Style

    19AJ-501 19 14.8 1.63 1.16 Standard

    21AJ-501 21 16.7 2.06 1.51 Standard

    23AJ-501 23 18.6 2.55 2.03 Standard

    25AJ-501 25 20.4 3.09 2.59 Standard

    27AJ-501 27 22.5 3.67 3.08 Standard

    29AJ-501 29 24.2 4.41 Not reported Standard

    31AJ-501 31 26.1 5.18 Not reported Standard

    Ordering Information

    Contents: Aortic Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    Standard Cuff

    Aortic Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    The expanded Masters aortic cuff has approximately 25% more cuff

    than the standard cuff

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic

    Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    M h i l H t V l

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    23/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    Effective

    Orifice Area6

    (cm2) Cuff Style

    19AECJ-502 19 14.8 1.63 1.16 Expanded

    21AECJ-502 21 16.7 2.06 1.51 Expanded

    23AECJ-502 23 18.6 2.55 2.03 Expanded

    25AECJ-502 25 20.4 3.09 2.59 Expanded

    27AECJ-502 27 22.5 3.67 3.08 Expanded

    29AECJ-502 29 24.2 4.41 Not reported Expanded

    31AECJ-502 31 26.1 5.18 Not reported Expanded

    Ordering Information

    Contents: Aortic Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    Expanded Cuff

    Aortic Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    The expanded Masters aortic cuff has approximately 25% more cuff

    than the standard cuff

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic

    Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    24/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue AnnulusDiameter

    (mm)

    Valve OrificeInner Diameter

    (mm)

    GeometricOrifice Area

    (cm2)

    EffectiveOrifice Area6

    (cm2) Cuff Style

    19ATJ-503 19 14.8 1.63 1.16 PTFE

    21ATJ-503 21 16.7 2.06 1.51 PTFE

    23ATJ-503 23 18.6 2.55 2.03 PTFE

    25ATJ-503 25 20.4 3.09 2.59 PTFE

    27ATJ-503 27 22.5 3.67 3.08 PTFE

    29ATJ-503 29 24.2 4.41 Not reported PTFE

    31ATJ-503 31 26.1 5.18 Not reported PTFE

    Ordering InformationContents: Aortic Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    PTFE Cuff

    Aortic Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent Mechanical Heart Valve: Laboratory Measurements of Hydrodynamic

    Performance. J Heart Valve Dis.1999 Nov;8(6):687-96.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    25/60

    Mechanical Heart Valves

    Model/Reorder

    Number

    Tissue Annulus

    Diameter (mm)

    Valve Orifice Inner

    Diameter (mm)

    Geometric Orifice

    Area (cm2) Cuff Style

    17MHPJ-505 17 14.8 1.63 Standard

    19MHPJ-505 19 16.7 2.06 Standard

    21MHPJ-505 21 18.6 2.55 Standard

    23MHPJ-505 23 20.4 3.09 Standard

    25MHPJ-505 25 22.5 3.67 Standard

    27MHPJ-505 27 24.2 4.41 Standard

    Ordering InformationContents: Mitral Valve (1 unit per box)

    Masters HPMechanical Heart Valve

    Standard Cuff

    Mitral Valves

    Product Highlights Sewing cuff redesigned to facilitate supra-annular placement, allowing

    for an increase in orifice size for a given tissue annulus diameter

    Increased geometric orifice area (GOA), lower pressure gradients,

    and improved performance1,2

    85 degree leaflet opening angle offers improved laminar flowand reduces turbulence1-3

    Controlled torque rotation mechanism allows for easy rotation

    and intraoperative adjustment

    Minimizes interference with sub-valvular structures

    St. Jude Medical heart valves are MR conditional4

    1. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    2. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    3. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    4. St. Jude Medical MRI Safety Document.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    26/60

    Mechanical Heart Valves

    Model/ReorderNumber

    Tissue AnnulusDiameter (mm)

    Valve Orifice InnerDiameter (mm)

    Geometric OrificeArea (cm2) Cuff Style

    19MJ-501 19 14.8 1.63 Standard

    21MJ-501 21 16.7 2.06 Standard

    23MJ-501 23 18.6 2.55 Standard

    25MJ-501 25 20.4 3.09 Standard

    27MJ-501 27 22.5 3.67 Standard

    29MJ-501 29 24.2 4.41 Standard31MJ-501 31 26.1 5.18 Standard

    33MJ-501 33 26.1 5.18 Standard

    35MJ-501 35 26.1 5.18 Standard

    37MJ-501 37 26.1 5.18 Standard

    Ordering InformationContents: Mitral Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    Standard Cuff

    Mitral Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    27/60

    c c

    Model/Reorder

    Number

    Tissue Annulus

    Diameter (mm)

    Valve Orifice Inner

    Diameter (mm)

    Geometric Orifice

    Area (cm2) Cuff Style

    19MECJ-502 19 14.8 1.63 Expanded

    21MECJ-502 21 16.7 2.06 Expanded

    23MECJ-502 23 18.6 2.55 Expanded

    25MECJ-502 25 20.4 3.09 Expanded

    27MECJ-502 27 22.5 3.67 Expanded

    29MECJ-502 29 24.2 4.41 Expanded

    31MECJ-502 31 26.1 5.18 Expanded

    33MECJ-502 33 26.1 5.18 Expanded

    Ordering Information

    Contents: Mitral Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    Expanded Cuff

    Mitral Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    The expanded mitral cuff has approximately 25% more cuff than

    the standard mitral cuff

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    28/60

    Model/Reorder

    Number

    Tissue Annulus

    Diameter (mm)

    Valve Orifice Inner

    Diameter (mm)

    Geometric Orifice

    Area (cm2) Cuff Style

    19MTJ-503 19 14.8 1.63 PTFE

    21MTJ-503 21 16.7 2.06 PTFE

    23MTJ-503 23 18.6 2.55 PTFE

    25MTJ-503 25 20.4 3.09 PTFE

    27MTJ-503 27 22.5 3.67 PTFE

    29MTJ-503 29 24.2 4.41 PTFE

    31MTJ-503 31 26.1 5.18 PTFE

    33MTJ-503 33 26.1 5.18 PTFE

    Ordering Information

    Contents: Mitral Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    PTFE Cuff

    Mitral Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    The expanded PTFE cuf has approximately 16% more cuff than the

    standard PTFE cuff

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    29/60

    Model/Reorder

    Number

    Tissue Annulus

    Diameter (mm)

    Valve Orifice Inner

    Diameter (mm)

    Geometric Orifice

    Area (cm2) Cuff Style

    19METJ-504 19 14.8 1.63 Expanded PTFE

    21METJ-504 21 16.7 2.06 Expanded PTFE

    23METJ-504 23 18.6 2.55 Expanded PTFE

    25METJ-504 25 20.4 3.09 Expanded PTFE

    27METJ-504 27 22.5 3.67 Expanded PTFE

    29METJ-504 29 24.2 4.41 Expanded PTFE

    31METJ-504 31 26.1 5.18 Expanded PTFE

    33METJ-504 33 26.1 5.18 Expanded PTFE

    Ordering Information

    Contents: Mitral Valve (1 unit per box)

    Masters Series Mechanical Heart Valve

    Expanded PTFE Cuff

    Mitral Valves

    Product Highlights Pyrolytic carbon leaflets and orifice ring offer exceptional durability

    and increased thromboresistance1

    85 degree leaflet opening angle offers improved laminar flow

    and reduces turbulence2-4

    Controlled torque rotation mechanism allows for easy rotationand intraoperative adjustment

    The expanded PTFE cuf has approximately 16% more cuff than the

    standard PTFE cuff

    St. Jude Medical heart valves are MR conditional5

    1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.

    Ann Thorac Surg.2005; 79:776-83.

    2. King, M, David T, Fisher J. An Initial Parametric Study on Fluid Flow Through Bileaflet Mechanical Heart Valves Using Computational Fluid Dynamics.

    J Eng Med1994: 208:63-72.

    3. Feng Z, Nakamura T, Fujimoto T et al. In Vitro Investigation of Opening Behavior and Hydrodynamics of Bileaflet Valves in the Mitral Position. Artificial Organs

    2002;26(1):32-9.

    4. Shipkowitz T, Ambrus J, Kurk J, Wickramasinghe K. Evaluation Technique for Bileaflet Mechanical Valves. J Heart Valve Dis.2002, Mar; 11 (2):275-82.

    5. St. Jude Medical MRI Safety Document.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered and

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    30/60

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Graft Inner

    Diameter

    (mm)

    Skirt Diameter

    (mm) +/- 10%

    (inflated)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    19VAVGJ-515 19 20 26 16.7 2.06

    21VAVGJ-515 21 22 28 18.6 2.55

    23VAVGJ-515 23 24 32 20.4 3.09

    25VAVGJ-515 25 26 34 22.5 3.67

    27VAVGJ-515 27 28 36 24.2 4.41

    29VAVGJ-515 29 30 38 26.1 5.18

    Ordering InformationContents: Aortic Valved Graft (1 unit per box)

    Masters HPValved Graft

    with Gelweave ValsalvaTechnology

    Aortic Valved Grafts

    Product Highlights Patented Valsalva design mimics natural anatomy and eases

    anastomotic suturing1-3

    Gelweave technology gelatin coating aids in tissue ingrowth4

    Low porosity graft enables zero pre-clotting4

    Expanded cuff designed to minimize potential for paravalvular leak Graft length is 10 cm minimum

    St. Jude Medical heart valves are MR conditional5

    1. De Paulis R, De Matteis GM, Nardi P, et al. A New Aortic Dacron Conduit for Surgical Treatment of Aortic Root Pathology. Ital Heart J.2000 Jul;1(7):457-63.

    2. De Paulis R, Bassano C, Scaffa R, et al. Bentall Producures with a Novel Valved Conduit Incorporating Sinuses of Valsalva. Surg Technol Int.

    2004;12:195-200.

    3. De Paulis R, De Matteis GM, Nardi P, et al. One-year Appraisal of a New Aortic Root Conduit with Sinuses of Valsalva. J Thorac Cardiovasc Surg.

    2002 Jan;123(1):33-9.

    4. From Manufacturers Literature: Vascutek, Ltd.

    5. St. Jude Medical MRI Safety Document.

    Gelweave Valsalva is a trademark of Vascutek, Ltd.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    31/60

    Model/Reorder

    Number

    Tissue Annulus

    Diameter

    (mm)

    Graft Inner

    Diameter

    (mm)

    Valve Orifice

    Inner Diameter

    (mm)

    Geometric

    Orifice Area

    (cm2)

    19CAVGJ-514-00 19 20 14.7 1.63

    21CAVGJ-514-00 21 22 16.7 2.06

    23CAVGJ-514-00 23 24 18.5 2.55

    25CAVGJ-514-00 25 28 20.4 3.09

    27CAVGJ-514-00 27 30 22.3 3.6729CAVGJ-514-00 29 32 24.1 4.41

    31CAVGJ-514-00 31 34 26.0 5.18

    33CAVGJ-514-00 33 34 26.0 5.18

    Ordering InformationContents: Aortic Valved Graft (1 unit per box)

    Masters Valved Graft

    with HemashieldTechnology

    Aortic Valved Grafts

    Product Highlights Hemashield technology graft with collagen impregnation provides

    uniform tissue ingrowth and biocompatibility1

    Low porosity graft requires no pre-clotting1

    No pleats at valve cuff allow for easy positioning and attachment

    of coronary anastomosis

    1

    Graft length is 12 cm

    St. Jude Medical heart valves are MR conditional2

    1. From Manufacturers Literature: MAQUET Cardiovascular.

    2. St. Jude Medical MRI Safety Document.

    Hemashield is a registered trademark of Maquet Cardiovascular LLC.

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    HP ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Mechanical Heart Valves

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    32/60

    Ordering InformationContents: 7 Double-ended Aortic Sizers, 1 Valve Holder Handle and 1 Autoclave-able Tray with Cover (1 unit per box)

    RegentMechanical Heart Valve Sizer SetAccessories

    Product Highlights Designed to facilitate proper size selection of the Regent mechanical heart valve

    in a supra-annular position

    Sizes 17 mm 29 mm

    The cylindrical end determines the appropriate size of the annulus

    The corresponding Regent valve replica end is used to visualize placement

    Malleable nitinol sizer and holder handle can be bent in any direction up to

    90 degrees without degradation

    Sizer and holder handle return to original straight shape during sterilization

    Model/ReorderNumber Description

    907 Sizer Set, Complete

    905-HH Valve Holder Handle

    AG-RHR Replacement Regent Valve Holder/Rotators, Sizes 17 mm29mm

    LT100 Mechanical Valve Leaflet Tester

    Rx Only

    St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic

    valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection,

    hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the

    physicians manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

    Regent ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    33/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    34/60

    Valve Repair

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    35/60

    Valve Repair

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    36/60

    Model/ReorderNumber Ring Size

    Fixed Dimension(mm) (A)

    Ring InnerDimension (mm) (B)

    Ring OuterDimension (mm) (C)

    AFR-25 25 25 28.4 33.4

    AFR-27 27 27 31.2 36.2

    AFR-29 29 29 34.0 39.0

    AFR-31 31 31 36.6 41.6

    AFR-33 33 33 39.4 44.4

    AFR-35 35 35 40.9 45.9

    AFR-37 37 37 43.7 48.7

    AFR-39 39 39 46.2 51.2

    AFR-41 41 41 49.0 54.0

    AFR-43 43 43 51.6 56.6

    Ordering InformationContents: Flexible Adjustable Annuloplasty Ring (1 unit per box)

    AttuneFlexible Adjustable Annuloplasty RingFlexible Ring

    Product Highlights Fully flexible design allows dynamic movement of the annulus

    Symmetrical and asymmetrical adjustability is designed to achieve ideal

    leaflet coaptation and match each patients annulus

    Adjustability after placement is designed to help eliminate residual

    mitral regurgitation

    Independent adjustability allows the annuloplasty to be localized to one side

    Suitable for implant using open sternotomy, minimally invasive

    and robotic approaches

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications,

    contraindications, warnings, precautions, potential adverse events, and directions for use.

    Attune ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    37/60

    Ordering InformationContents: Flexible Ring (1 unit per box)

    TailorFlexible Annuloplasty RingFlexible Ring

    Product Highlights Designed to maintain the size of a repaired mitral or tricuspid annulus while

    sustaining physiologic movement

    Anterior and posterior support allows dynamic annular motion during the

    cardiac cycle

    Flexible design aids cardiac output and left ventricular function, supporting

    optimal hemodynamics1-3

    Large target area eases suturing

    Suitable for implant using open sternotomy, minimally invasive

    and robotic approaches

    Model/Reorder

    Number Ring Size

    Inside

    Dimension (mm) (B)

    Outside

    Dimension (mm) (C)

    Intertrigonal

    Dimension (mm) (A)

    TARP-25 25 28.4 34.4 25

    TARP-27 27 31.2 37.2 27

    TARP-29 29 34.0 40.0 29

    TARP-31 31 36.6 42.6 31

    TARP-33 33 39.4 45.4 33

    TARP-35 35 40.9 47.9 35

    1. Yamaura Y, Yoshikawa J, Yoshida K, et al. Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane

    transesophageal echocardiography: Comparison between flexible and rigid annuloplasty rings. J Heart Valve Dis.1995;4(6)61822.

    2. Kunzelman K, Reimink S, Cochran P. Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model. J Heart Valve Dis.

    1998;7(1)108.

    3. David T, Armstrong S, Sun Z. Left ventricular function after mitral valve surgery. J Heart Valve Dis.1995;4(Supl) S17580.

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    Tailor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    38/60

    Ordering InformationContents: Flexible Band (1 unit per box)

    TailorFlexible Annuloplasty BandFlexible Band

    Product Highlights Band offers simple alternative and time-saving simplicity to flexible rings

    Posterior support allows dynamic annular motion

    Flexible design aids cardiac output and left ventricular function, supporting

    optimal hemodynamics1-3

    Large target area eases suturing

    Suitable for implant using open sternotomy, minimally invasive

    and robotic approaches

    Model/ReorderNumber Ring Size

    InsideDimension (mm) (B)

    OutsideDimension (mm) (C)

    IntertrigonalDimension (mm) (A)

    TAB-25 25 28.4 34.4 25

    TAB-27 27 31.2 37.2 27

    TAB-29 29 34.0 40.0 29

    TAB-31 31 36.6 42.6 31

    TAB-33 33 39.4 45.4 33

    TAB-35 35 40.9 47.9 35

    1. Yamaura Y, Yoshikawa J, Yoshida K, et al. Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane

    transesophageal echocardiography: Comparison between flexible and rigid annuloplasty rings. J Heart Valve Dis.1995;4(6)61822.

    2. Kunzelman K, Reimink S, Cochran P. Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: A finite element model. J Heart Valve Dis.

    1998;7(1)108.

    3. David T, Armstrong S, Sun Z. Left ventricular function after mitral valve surgery. J Heart Valve Dis.1995;4(Supl) S17580.

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    Tailor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    39/60

    A

    A

    B

    C

    Internal 2-DOrifice Area

    Ordering InformationContents: Rigid Saddle Ring (1 unit per box)

    SJMRigid Saddle RingRigid / Semi-Rigid Rings

    Product Highlights Designed to restore the shape of a healthy mitral annulus1

    Titanium core maintains the anatomical shape and provides annular remodeling

    Saddle shape contributes to efficient distribution of leaflet stress and chordal tension

    which may increase repair durability1-4

    EZ Suture Cuff is supported by a unique triangular core for a larger suture target

    Model/Reorder

    Number Ring Size

    CommisureDimension

    (mm) (A)

    InsideDimension

    (mm) (B)

    OutsideDimension

    (mm) (C)

    A-PDimension

    (mm) (D)

    Internal 2-DOrifice Area

    (mm2)

    RSAR-24 24 24 22 30 13.6 227

    RSAR-26 26 26 24 32 15.1 276

    RSAR-28 28 28 26 34 16.2 331

    RSAR-30 30 30 28 26 17.9 387

    RSAR-32 32 32 30 38 19.2 450

    RSAR-34 34 34 32 40 20.6 511

    1. Jimenez JH, Soerensen DD, He Z, et al. Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: an in vitro study.

    Ann Biomed Eng.2003;31(10):1171-81.

    2. Salgo IS, Gorman JH 3rd, Gorman RC, et al. Effect of annular shape on leaflet curvature in reducing mitral leaflet stress. Circulation.2002;106(6):711-7.

    3. Jimenez JH, Liou SW, Padala M, et al. A saddle-shaped annulus reduces systolic strain on the central region of the mitral valve anterior leaflet.

    J Thorac Cardiovasc Surg.2007;134(6):1562-8.

    4. Gorman JH 3rd, Jackson BM, Enomoto Y, et al. The effect of regional ischemia on mitral valve annular saddle shape. Ann Thorac Surg. 2004;77(2):544-8.

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

    SJM S i S i Ri id A l l t Ri

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    40/60

    Internal 2-D

    Orifice Area

    B

    C

    A

    Ordering InformationContents: Semi-Rigid Ring (1 unit per box)

    SJMSguin Semi-Rigid Annuloplasty RingRigid / Semi-Rigid Rings

    Product Highlights Designed to aid cardiac output and left ventricular function1

    Semi-rigid, three-dimensional posterior section is designed to preserve the

    physiologic movement of the valve annulus1

    Increased rigidity of the anterior section of the ring promotes annular remodeling 1

    The solid, one piece inner core resists needle penetration, reducing the potential

    for suturing through the core

    Model/Reorder

    Number Ring Size

    CommisureDimension

    (mm) (A)

    InsideDimension

    (mm) (B)

    OutsideDimension

    (mm) (C)

    Internal 2-DOrifice Area

    (mm2)

    SARP-24 24 24 22 29 284

    SARP-26 26 26 24 31 334

    SARP-28 28 28 27 34 404

    SARP-30 30 30 28 35 463

    SARP-32 32 32 30 37 541

    SARP-34 34 34 34 41 602

    SARP-36 36 36 36 43 630

    SARP-38 38 38 37 45 735

    SARP-40 40 40 39 46 815

    1. Sguin J, Demaria R, Chaptal PA. Preservation of three-dimensional annular movement with the SJM-Seguin mitral annuloplasty ring. J Heart Valve Dis.

    1996;5(6):641-46.

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

    SJM P i a dial Pat h

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    41/60

    Ordering InformationContents: Pericardial Patch (1 unit per box)

    SJMPericardial Patch

    with EnCapAC TechnologyPericardial Patch

    Product Highlights Flexible and durable to provide enhanced biocompatibility and lasting performance1-3

    Bovine pericardium provides improved handling and suturability compared

    with synthetic patches4

    Anti-calcification treatment enhances tissue healing, biocompatibility and long-term

    tissue stability1*

    Thinner patch available to accommodate pediatric applications5

    Soft, pliable tissue conforms to the anatomy and easily sutures into place

    Ready-to use, rinseless preparation saves time during procedures

    *There is no clinical data currently available which evaluates the long-term impact of anticalcification treatment in humans.

    1. Frater RWM, Seifter E, Liao K, et al. Anticalcification, proendothelial, and anti-inflammatory effect of post-aldehyde polyol treatment of bioprosthetic material.

    In: Gabbay S, Wheatley DJ (eds.). Advances in Anticalcific and Antidegenerative Treatment of Heart Valve Bioprostheses.Austin, TX: Silent Partners Inc;

    1997:105-14.

    2. Frater RWM, Liao K, Seifter E. Stentless chordally supported mitral bioprosthetic valve. In: Gabbay S, Frater RWM (eds.) New Horizons and the Future of Heart

    Valve Bioprostheses.Austin, TX: Silent Partners Inc; 1994:103-19.

    3. Hoffman D, Gong G, Liao K, et al. Spontaneous host endothelial growth on bioprostheses. Circulation.1992;86[suppl II]:II-75-II-79.

    4. Crawford FA Jr, Sade RM, Spinale F. Bovine pericardium for correction of congenital heart defects. Ann Thorac Surg.1986;41(6):602-5.

    5. Hopkins, et. al. Surgical Patch Closure of Atrial Septal Defects. Ann Thorac Surg.2001;77-2144-50.

    EnCap is a trademark of Glycar, Inc.

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Model/Reorder

    Number

    Patch Size

    (cm)

    Nominal Thickness

    (mm)

    C0205 2 x 5 0.20 0.40

    C0405 4 x 5 0.150.25

    C0510 5 x 10 0.20 0.40

    C0914 9 x 14 0.20 0.40

    Valve Repair

    Tailor Annuloplasty Ring Sizer Set

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    42/60

    Tailor Annuloplasty Ring Sizer SetAccessories

    Product Highlights Designed to facilitate proper size selection of the Tailor ring and band

    and Attunering

    Sizes 25 mm 35 mm

    Malleable nitinol sizer and holder handle can be bent in any direction up to

    90 degrees without degradation

    Ordering InformationContents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover

    Model/ReorderNumber Description

    TAR-505 Tailor Flexible Ring Set, Complete

    HH-05 Replacement Holder Handle

    EX-05 Replacement Extension Handle

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    Tailor Attune ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

    SJM Rigid Saddle Ring Sizer Set

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    43/60

    Ordering InformationContents: 6 Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover

    SJM Rigid Saddle Ring Sizer SetAccessories

    Product Highlights Designed to facilitate proper size selection of the SJM Rigid Saddle annuloplasty ring

    Sizes 24 mm 34 mm

    Malleable nitinol sizer and holder handle can be bent in any direction up to

    90 degrees without degradation

    Model/ReorderNumber Description

    RSAR-507A SJM Rigid Saddle Ring Sizer Set, Compete

    HH-05 Replacement Holder Handle

    EX-05 Replacement Extension Handle

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential

    adverse events, and directions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Valve Repair

    SJM Sguin Semi-Rigid Annuloplasty Ring

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    44/60

    SJM Sguin Semi Rigid Annuloplasty Ring

    Sizer SetAccessories

    Product Highlights Designed to facilitate proper size selection for the SJM Seguin annuloplasty ring

    Sizes 24 mm 40 mm

    Malleable nitinol sizer and holder handle can be bent in any direction up to

    90 degrees without degradation

    Ordering InformationContents: 9 Mitral Sizers, 1 Malleable Holder Handle, 1 Extension Handle and 1 Autoclavable Tray and Cover

    Model/ReorderNumber Description

    SAR-501 SJM Sguin Semi-Rigid Ring Sizer Set, Complete

    HH-05 Replacement Holder Handle

    EX-05 Replacement Extension Handle

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications,

    contraindications, warnings, precautions, potential adverse events, and directions for use.

    ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    45/60

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    46/60

    Cardiac Ablation

    Cardiac Ablation

    Cardiac Ablation Table of Contents

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    47/60

    EpicorCardiac Ablation System

    Epicor

    Ablation Control System (ACS)...................................................................................................CA2

    EpicorLP Cardiac Ablation System

    UltraCinchLP Ablation Device .............................................................................................................CA3

    UltraWandLP Handheld Ablation Device ..............................................................................................CA4

    LP Connecting Cable..............................................................................................................................CA5

    LP Positioning and Sizing (LP PAS) System ............................................................................................CA6

    LP Oblique Introducer ............................................................................................................................CA7

    Universal IV Set .....................................................................................................................................CA8

    Cardiac Ablation

    EpicorAblation Control System (ACS)

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    48/60

    Ordering InformationContents: Ablation Control System (1 unit per box)

    Epicor Cardiac Ablation System

    Product Highlights Utilizes high intensity focused ultrasound (HIFU) to surgically ablate cardiac tissue

    concomitant with cardiac surgery

    Designed to create lesions entirely epicardially while the patient is off-pump

    Simple one-button control

    Intuitive user display provides real-time information on ablation cycle progress

    and system performance

    Power, frequency, and temperature display and monitoring

    Integrated safety features and real-time help screens

    Scalable architecture for ongoing system and software upgrades

    Model/Reorder

    Number

    Power

    Configuration

    ACS-US-2 100-120 V, 60 Hz, 1000 VA

    Rx Only

    Please review the Instructions for Use prior to using these devices for Use for a complete listing of indications,

    contraindications, warnings, precautions, potential adverse events, and directions for use.

    Epicor ST JUDE MEDICAL the nine squares symbol and MORE CONTROL LESS RISK are registered

    Cardiac Ablation

    UltraCinchLP Ablation Device

  • 8/13/2019 2011 CardiacSurgery Catalog US 062811

    49/60

    Ordering InformationContents: UltraCinch LP Ablation Device (1 unit per box)

    EpicorLP Cardiac Ablation System

    Product Highlights An array of high intensity focused ultrasound (HIFU) emitting transducers creates a

    contiguous, circular lesion in a single step, entirely epicardially and off-pump

    A flexible transducer cell array, low transducer cell profile and a tapered distal end

    make it equally suited for use in open- or closed-chest procedures

    Integrated tensioning sutures prevent device migration and keep energy focused

    on targeted tissue

    Single-plane energy delivery designed to reduce the risk of collateral damage Multiple sizes accommodate varying anatomy

    Ablates through fat, eliminating the need for dissection

    Model/Reorder

    Number

    Size

    (cells)

    UC-LP-7 7

    UC-LP-8 8

    UC-LP-9 9

    UC-LP-10 10

    UC-LP-11 11

    UC-LP-12 12

    UC-LP-13 13

    Rx Only

    Please review the Instructions for Use prior to using these devices for a complete listing of indications,

    contraindications, warnings, precautions, potential adverse events, and directions for use.