2010 California Plumbing / Mechanical Supplements
Tim Dunn
City of Ventura
Plans Examiner Job Description
Field Plumbologist Job Duties
Blue Sheet Amendments || This symbol indicates that a change has
been made to a California Amendment.
> This symbol indicates deletion of California language.
For time constraints only relevant material will be reviewed
Lets start with the Plumbing Code
Plumbing Code Book
Rationale:
Section 1.13.0 Depart Of Water Resources Section 1.13.1 was merely relocated
section number only, language is the same. A loss of redundant language stating “DWR – Department of Water Resources.”
Section 1.13.2 Application D.W.R. 1.13.2 Application – installation, construction,
alteration, or repair of recycled water systems for water closets, urinals, trap primers for floor drains, floor sinks and other allowed areas.
Enforcing Agency – State or local agency specified by applicable provisions of law.
Authority Cited – Water Code section 13557 References – Water Code Section 13553
Significant for Section 1.13.2 This added language is in correlation to
the new Chapter 16A for non-potable water reuse system.
Per The Building and Standards and HCD Department this Chapter will be evolving especially in the area of home reuse water systems.
Chapter 4 Table 4-2 Minimum
Footnote changes table 4-2
Footnote 5
Footnote 8
Footnote 12
Footnotes 20 and 29
Rational by OSHPD
Chapter 12 Fuel Piping
Mis-print in Matrix adoption. Building Standards Commission adopted all of Chapter, not portions.
Section 1211.18
Rational
Tables 12-38; 12-39; 12-41Error in wording only, and pipe sizing
table change.
Appendix F FireFighter AirDon’t adopt or review, Don’t care.
Mechanical Code book
All Yawn together for repeat information.
Section 1.8.8 same changes as Plumbing Code.
Chapter 3 Changes
Section 314.3 Omitted All Deleted belowRequirements for outpatient facilities and
Licensed Clinics. (OSHPD3)“The system shall be designed to provide
the temperature and humidties for sensitive areas for rooms shown in table 315.”
Section 315.3 and Table 315
Entire new Section Below
315.3 Requirements for outpatient Facilities and Licensed Clinics. ( For OSHPD 3 )
315.3.1 The system for sensitive areas for rooms shown in Table 315.
Table 315
Rational
Chapter 4 table 4-A
Table 4-A Ventilation
Rationale:
Matrix adoption change Ch. 6
Section 605.0
New Duct insulaltion Table 6-6
Rationale
Please learn OSHPDStanding here looking at myself and all
my friends, you are all my friends, WE are all getting old.
A loved one, or yourself, or more importantly I may be old and ill at some time. Keep us all safe.