201 pump condition evaluation[1]

15
PUMP CONDITION PUMP CONDITION EVALUATION EVALUATION

Upload: aqibazizkhan

Post on 22-Apr-2017

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Page 2: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

• BEARINGS• PUMP SHAFT• BEARING FRAME• REAR COVER • IMPELLER• PUMP CASE

Page 3: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Vibration - Imperfections on rollers/balls will cause seal face “chatter”

End Play - Closing force on the seal faces will vary

Run Out Seal faces will not run in a concentric path Seal faces will not run parallel Vibration will occur

•BEARINGS

Page 4: 201 Pump Condition Evaluation[1]

CHECKING BEARING RELATED END PLAYCHECKING BEARING RELATED END PLAY

Total Indicator Readingshould not exceed

.010”

Page 5: 201 Pump Condition Evaluation[1]

CHECKING BEARING RELATED END PLAYCHECKING BEARING RELATED END PLAY

“TIR” should not exceed.010”

Page 6: 201 Pump Condition Evaluation[1]

CHECKING BEARING RELATED RUN OUTCHECKING BEARING RELATED RUN OUT

TIR should not exceed.002”

Page 7: 201 Pump Condition Evaluation[1]

CHECKING BEARING RELATED RUN OUTCHECKING BEARING RELATED RUN OUT

“TIR” should not exceed.002”

Page 8: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Bent Shaft Run Out Vibration

Bearing FitsRun OutEnd Play

Shaft Sleeve Fit - Run Out Impeller Thread/Fit - Vibration

•PUMP SHAFT

Page 9: 201 Pump Condition Evaluation[1]

CHECKING SHAFT RELATED RUN OUTCHECKING SHAFT RELATED RUN OUT“TIR” should not exceed

.001” per 2” distance from bearing

6” = TIR max of .0036” = TIR max of .003

Page 10: 201 Pump Condition Evaluation[1]

CHECKING SHAFT RELATED RUN OUTCHECKING SHAFT RELATED RUN OUTTIR should not exceed.001” per 2” distance

from bearing

3” = TIR .00153” = TIR .0015

Page 11: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Outboard Bearing Housing fit in Frame Bearing Fits

Run OutBearing SpinVibration

•BEARING FRAME

Page 12: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Seal chamber / Gland fit - Gland Boss must be perpendicular to the pump shaft

Imperfections or wear on the impeller side of the rear cover will effect the performance of pump out vanes which in turn, effects seal chamber conditions

Stuffing box pressure fluid turbulence

•REAR COVER

Page 13: 201 Pump Condition Evaluation[1]

CHECKING GLAND BOSS FOR CHECKING GLAND BOSS FOR PERPENDICULARITYPERPENDICULARITY

“TIR” should not exceed.005” up to 5” Dia. (+.001"/in. >5”)

Page 14: 201 Pump Condition Evaluation[1]

PUMP CONDITION PUMP CONDITION EVALUATIONEVALUATION

Excessive wear will effect pump performance which will effect stuffing box conditions

Impeller fit on shaft must be true With open impeller pumps, proper impeller

/ case clearance is a must for optimum pump performance and must be done before installing a new seal

•IMPELLER & PUMP CASE

Page 15: 201 Pump Condition Evaluation[1]

ENDENDPUMP CONDITION PUMP CONDITION

EVALUATIONEVALUATION