2008-04
Preparation of Transporter (I)
- turn the green knurled nut of the Transporter, as shown, anticlockwise, until the cartridge can be placed in the Transporter´s compartment.
Transporter
![Page 3: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/3.jpg)
2008-04
Preparation of Transporter (II)
- take the cartridge and put it into the Transporter´s compartment.
cartridge
![Page 4: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/4.jpg)
2008-04
Preparation of Transporter (III)
- for a safe and firm seat of the cartridge, turn the green knurled nut of the Transporter clockwise, as shown, until the plunger softly touches the rubber end of the cartridge.
![Page 5: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/5.jpg)
2008-04
Preparation of Transporter (IV)
- take the Transporter Adapter out of it´s sterile packaging.
- screw the Transporter Adapter on to the Transporter. Ensure that the adapter needle pierces the rubber seal of the cartridge.
![Page 6: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/6.jpg)
2008-04
Filling of Ampoule (I)
- take an INJEX-Ampoule out of it´s sterile packaging and press the plunger completely into the INJEX-Ampoule to force the air out of the Ampoule.
Ampoule
plunger
![Page 7: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/7.jpg)
2008-04
- open the protective cap of the Transporter Adapter.
- screw the INJEX-Ampoule, clockwise, as shown, into the open end of the Adapter until it fits tightly.
Filling of Ampoule (II)
![Page 8: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/8.jpg)
2008-04
Filling of Ampoule (III)
- turn the green knurled nut at the upper end of the Transporter, clockwise, as shown, until the desired dose of the pharmaceutical agent is in the INJEX-Ampoule.
![Page 9: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/9.jpg)
2008-04
- unscrew the filled INJEX-Ampoule from the Adapter in an anticlockwise direction and close the protective cap.
Filling of Ampoule (IV)
![Page 10: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/10.jpg)
2008-04
Preparation of the Injector (I)
- take the loaded and safeguarded Injector out of the Reset Box.
Injector
Reset-Box
![Page 11: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/11.jpg)
2008-04
Preparation of the Injector (II)
- screw the filled INJEX-Ampoule clockwise into the open end of the Injector (the last round goes a little bit harder, this is normal).
![Page 12: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/12.jpg)
2008-04
Preparation of the Injector (III)
- push the green safety ring towards the Ampoule into „Safe off“ position. Now the Injector is ready for use.
![Page 13: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/13.jpg)
2008-04
The Injection- hold the Injector under firm pressure perpendicularly to the
injection site (i.e. abdomen), until a clear indentation forms on the skin. Press the trigger and release the injection. Hold the Injector on the injection site for another 1 – 2 sec.
![Page 14: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/14.jpg)
2008-04
- unscrew the INJEX-Ampoule and discard it – domestic waste -.
After the Injection (I)
![Page 15: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/15.jpg)
2008-04
- push the green safety ring back into the „Safe“ position.
- store the secured and non-reset Injector and its accessories in the INJEX Case.
After the Injection (II)
![Page 16: 2008-04 INJEX Pharma GmbH INJEX Operation Needle-Free Injection Technology](https://reader034.vdocuments.us/reader034/viewer/2022051515/5519eb2a550346d67b8b4b5f/html5/thumbnails/16.jpg)
2008-04
INJEX Pharma GmbHBuckower Damm 11412349 Berlin, Germany+49-30-667 915 63www.injex.de