2. electrical interface to the generator set should …
TRANSCRIPT
CKD
FIRST USED ONFOR INTERPRETATIONOF DIMENSIONING ANDTOLERANCING, SEE
APVD
DWNSIM TOUNLESS OTHERWISE SPECIFIED, ALLDIMENSIONS ARE IN MILLIMETERS
17.50-24.99 +0.30/-0.13
10.00-17.49 +0.25/-0.13
5.00- 9.99 +0.20/-0.10
0.00- 4.99 +0.15/-0.08
DIM
HOLE
ANG TOL
DO NOT SCALE PRINT
SCALE
SITE CODE
CUMMINS POWER GENERATION
SIZEDWG
D
DATE
A053G027
6 5 4 3 2 1
D
C
B
A
6 5 4 3 2 1
D
C
B
A
PTC Creo ParametricR R
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) ISCONFIDENTIAL AND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERSIN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, ORUSED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
R
OF
CAD SHEET
1 4
NOREVREL NO DATEAPVDCKDDWNREVISION
1X �#�
0.8 .X �#�
0.38 .XX�#�
1.0 3/16 ARROWASME Y14.5-2009
01DEC15
E_NORDSTROM
E_NORDSTROM
R_WEHRENBERG
OUTLINE,GENSET
ECO-165422 D 1 SEE SHEET 2 BE BE D_GILLETT 10OCT16
PGF
.
TABULATION
MODEL DIM A DIM B GENERATOR SET WEIGHT
KG LB
C13 N6H 449 432 217 479
C17 N6H 465 432 241 531
C20 N6H 465 432 241 531
NOTES: 1. DIMENSIONS SHOWN IN [ ] ARE IN INCHES. 2. ELECTRICAL INTERFACE TO THE GENERATOR SET SHOULD BE WITH FLEXIBLE CONDUIT. 3. 2X MOUNTING SLEEVES 55 [2.2] LONG WITH �n�15 [0.6] THROUGH HOLE ARE PROVIDED LOOSE FOR SECURING GENERATOR SET TO MOUNTING SURFACE. 4. OIL DRAIN EXTENSION: 3/8 INCH ID HOSE. 5. FUEL INTERFACE TO THE GENERATOR SET MUST BE WITH AGENCY APPROVED FLEXIBLE FUEL LINE. 6 ACCESSORY MOUNTING PAD A052A795 APPROXIMATE WEIGHT 70 Kg (155 LB).
ENGINE OIL FILL
ENGINE OIL LEVEL DIPSTICK
CIRCUIT BREAKER BOX
LOCAL DISPLAY(GENERATOR SET START/STOP AND GRAPHICAL DISPLAY)
BATTERY
OPTIONAL ACCESSORY MOUNTING PAD
AIR INLET
HINGE LOCK
COVER LOCK
ECO-165422 Sheet 1 of 5Part Name: A053G027 Revision: D
Drawing Name: A053G028 Revision: D
CKD
FIRST USED ONFOR INTERPRETATIONOF DIMENSIONING ANDTOLERANCING, SEE
APVD
DWNSIM TOUNLESS OTHERWISE SPECIFIED, ALLDIMENSIONS ARE IN MILLIMETERS
17.50-24.99 +0.30/-0.13
10.00-17.49 +0.25/-0.13
5.00- 9.99 +0.20/-0.10
0.00- 4.99 +0.15/-0.08
DIM
HOLE
ANG TOL
DO NOT SCALE PRINT
SCALE
SITE CODE
CUMMINS POWER GENERATION
SIZEDWG
D
DATE
A053G027
6 5 4 3 2 1
D
C
B
A
6 5 4 3 2 1
D
C
B
A
PTC Creo ParametricR R
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) ISCONFIDENTIAL AND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERSIN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, ORUSED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
R
OF
CAD SHEET
2 4
NOREVREL NO DATEAPVDCKDDWNREVISION
91536[ ]
86534.1[ ]
69427.3[ ]
4X
LIFTING HOLES
321.3[ ]
2X 933.7[ ]
2X 72928.7[ ]
742.9[ ]
1003.9[ ]
1335.2[ ]
2007.9[ ]
4X 220.9[ ]
73028.7[ ]
682.7[ ]
2X 45818[ ]
2X 150.6[ ]
[1.4](1" CONDUIT FITTING)
ELECTRICAL CONNECTION(AC AND DC)
44617.5[ ]
722.8[ ]
DIM A
DIM B
2429.5[ ]
602.4[ ]
27010.6[ ]
753[ ]
35013.8[ ]
131451.7[ ]
99839.3[ ]
1335.2[ ]
502[ ]
1004[ ]
1X �#�
0.8 .X �#�
0.38 .XX�#�
1.0 3/16 ARROWASME Y14.5-2009
01DEC15
E_NORDSTROM
E_NORDSTROM
R_WEHRENBERG
OUTLINE,GENSET
ECO-165422 D 1 ZONE D6-ADD STOP SWITCH LOC AND DIMS BE BE D_GILLETT 10OCT16
PGF
.
AIR INTAKE
CG
APPROVED LOCATION FOR EXTERNALLY MOUNTED STOPSWITCH (NOT PROVIDED). MOUNTING HOLE NOT PROVIDED.
AREA AVAILABLE FOR ADDITIONAL ELECTRICAL CONNECTIONS
CG
AIR OUTLET
3/4" NPT FEMALE FUEL CONNECTION
SCALE 1/8
SCALE 1/8
3
ECO-165422 Sheet 2 of 5Part Name: A053G027 Revision: D
Drawing Name: A053G028 Revision: D
CKD
FIRST USED ONFOR INTERPRETATIONOF DIMENSIONING ANDTOLERANCING, SEE
APVD
DWNSIM TOUNLESS OTHERWISE SPECIFIED, ALLDIMENSIONS ARE IN MILLIMETERS
17.50-24.99 +0.30/-0.13
10.00-17.49 +0.25/-0.13
5.00- 9.99 +0.20/-0.10
0.00- 4.99 +0.15/-0.08
DIM
HOLE
ANG TOL
DO NOT SCALE PRINT
SCALE
SITE CODE
CUMMINS POWER GENERATION
SIZEDWG
D
DATE
A053G027
6 5 4 3 2 1
D
C
B
A
6 5 4 3 2 1
D
C
B
A
PTC Creo ParametricR R
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) ISCONFIDENTIAL AND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERSIN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, ORUSED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
R
OF
CAD SHEET
3 4
NOREVREL NO DATEAPVDCKDDWNREVISION
MINIMUM
TO STRUCTURES HAVINGCOMBUSTIBLE WALLS. 762 [30] MINIMUM UNOBSTRUCTED SPACE
762 30[ ] MINIMUM TO
STRUCTURES HAVINGCOMBUSTIBLE WALLS. 915 [36] MINIMUMUNOBSTRUCTED SPACEFREE OF COMBUSTIBLEITEMS
1524 60[ ] MINIMUM TO
STRUCTURES HAVINGCOMBUSTIBLE WALLS. 915 [36] MINIMUMUNOBSTRUCTED SPACE FREE OF COMBUSTIBLEITEMS
1524 60[ ] MINIMUM
TO STRUCTURES HAVINGCOMBUSTIBLE WALLS. 762 [30] MINIMUM UNOBSTRUCTED SPACE
762 30[ ]
MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS 458 [18] UNOBSTRUCTED SPACEFOR SERVICE ACCESS
458 18[ ]
MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS. 458 [18] MINIMUM UNOBSTRUCTEDSPACE FOR SERVICE ACCESS
1524 60[ ]
R MINIMUM TO
ANY OPENING IN AN OCCUPIED SPACE
1524 60[ ]R MINIMUM TO
ANY OPENING IN AN OCCUPIED SPACE
1524 60[ ]
MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS 458 [18] UNOBSTRUCTED SPACE FOR SERVICE ACCESS
458 18[ ]
R MINIMUM TO
ANY OPENING IN ANOCCUPIED SPACE
1524 60[ ]R MINIMUM TO
ANY OPENING IN ANOCCUPIED SPACE
1524 60[ ]
MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS. 458 [18] MINIMUM UNOBSTRUCTEDSPACE FOR SERVICE ACCESS
1524 60[ ]
MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS 1524 [60] MINIMUM TO ANYOPENING IN AN OCCUPIED SPACE
1524 60[ ] MINIMUM TO STRUCTURES
HAVING COMBUSTIBLE WALLS 1524 [60] MINIMUM TO ANYOPENING IN AN OCCUPIED SPACE
1524 60[ ]
1X �#�
0.8 .X �#�
0.38 .XX�#�
1.0 3/16 ARROWASME Y14.5-2009
01DEC15
E_NORDSTROM
E_NORDSTROM
R_WEHRENBERG
OUTLINE,GENSET
ECO-165422 D - --- BE BE D_GILLETT 10OCT16
PGF
.
SCALE 1/8
TOP OF GENERATOR SET
CIRCUITBREAKER
ENGINEEND
ALTERNATOR END
COMBUSTIBLE SURFACE/WALL
COMBUSTIBLE SURFACE/WALL
SCALE 1/8
TOP OF GENERATOR SET
CIRCUITBREAKER
ENGINEEND
ALTERNATOR END
COMBUSTIBLE SURFACE/WALL
COMBUSTIBLE SURFACE/WALL
SIDE OF GENERATOR SET SIDE OF GENERATOR SET
CLEARANCE REQUIREMENTS FOR GENERATOR SET INSTALLATIONS
AIR FLOWAIR FLOW AIR FLOW AIR FLOW
ECO-165422 Sheet 3 of 5Part Name: A053G027 Revision: D
Drawing Name: A053G028 Revision: D
CKD
FIRST USED ONFOR INTERPRETATIONOF DIMENSIONING ANDTOLERANCING, SEE
APVD
DWNSIM TOUNLESS OTHERWISE SPECIFIED, ALLDIMENSIONS ARE IN MILLIMETERS
17.50-24.99 +0.30/-0.13
10.00-17.49 +0.25/-0.13
5.00- 9.99 +0.20/-0.10
0.00- 4.99 +0.15/-0.08
DIM
HOLE
ANG TOL
DO NOT SCALE PRINT
SCALE
SITE CODE
CUMMINS POWER GENERATION
SIZEDWG
D
DATE
A053G027
6 5 4 3 2 1
D
C
B
A
6 5 4 3 2 1
D
C
B
A
PTC Creo ParametricR R
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) ISCONFIDENTIAL AND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERSIN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, ORUSED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
R
OF
CAD SHEET
4 4
NOREVREL NO DATEAPVDCKDDWNREVISION
77030.3[ ]
92936.6[ ]
97938.6[ ]
763[ ]
1X �#�
0.8 .X �#�
0.38 .XX�#�
1.0 3/16 ARROWASME Y14.5-2009
01DEC15
E_NORDSTROM
E_NORDSTROM
R_WEHRENBERG
OUTLINE,GENSET
ECO-165422 D - --- BE BE D_GILLETT 10OCT16
PGF
.
6
ECO-165422 Sheet 4 of 5Part Name: A053G027 Revision: D
Drawing Name: A053G028 Revision: D
Part A053G027 D
Part Specifications :A053G027 D
Description Legacy Name External Regulations Application Status Release Phase Code Security Classification Alternates
OUTLINE,GENSET A053G027 No External Regulations Apply Production Only Production Confidential
Name Description Legacy Name
A030B356 SPECIFICATION,MATERIAL CES10903
A053G028 DRAWING,ENGINEERING A053G028
ECO-165422 Sheet 5 of 5Part Name: A053G027 Revision: D
Drawing Name: A053G028 Revision: D