2 | | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services...

11

Upload: doannhu

Post on 16-Apr-2018

221 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100
Page 2: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

2 | www.heattech.co.za www.heattech.co.za | 3

Page 3: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

4 | www.heattech.co.za www.heattech.co.za | 5

5YEARWARRANTY*

THICK INNERSTEEL TANK

2mm

Page 4: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

6 | www.heattech.co.za www.heattech.co.za | 7

5YEARWARRANTY*

2YEARWARRANTY*

1YEARWARRANTY*

JOINT ACCEPTANCE SCHEME FOR WATER SERVICES INSTALLATION COMPONENTS

CERTIFICATE OF ACCEPTANCEEXPIRY DATE: 5 October 2014

THE FOLLOWING PRODUCT HAS BEEN ADDED TO THE LIST OF ACCEPTED COMPONENTS FOR USE IN WATER SERVICES

INSTALLATIONS

PRODUCT DESCRIPTION: Water Heater (storage), SANS 151 PRODUCT(S) ACCEPTED: Heat Tech Fixed electric storage water heater

(Standard)

Mark bearing product: Permit No 9537/15118

CATALOGUE REF Heat Tech Highline 100 ℓ and 150 ℓ / Trendline 100ℓ and 150ℓ (600kPa)

MANUFACTURER: Heat Tech Geysers (Pty) Ltd

SPECIAL CONDITIONS: Subject to SABS Certification Mark

APPLICATION NUMBER: 1586/1

________________for JASWIC

Issued to Heat Tech Geysers (Pty) Ltd

Heat Pump& Solar

CompatibleTHICK INNERSTEEL TANK

2mm 600kPaл

Page 5: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

8 | www.heattech.co.za www.heattech.co.za | 9

TrendlineGeysers

Stopcock

Mains Pressure

Balanced Cold Water

Pressure Control Valve

Drain Cock *Drip Tray

Vacuum Breaker Vacuum BreakerAnti - Siphon Loop

Above Top of Water Heater

Electrical Cover

Optional AnodeHeat Pump/SolarConnection or Plug*

Hot WaterOutlet

200 mm

300

mm

(MIN)

Safety Valve

300

mm

Stopcock

Mains Pressure

Safety Valve

Pressure Control Valve

Balanced Cold Water

Drain Cock *

Electrical Cover

Drip Tray

Hot WaterOutlet

300

mm

Optional AnodeHeat Pump/SolarConnection or Plug*

Anti - Siphon LoopAbove Top of Water Heater 30

0 m

m

Vacuum BreakerVacuum Breaker

Description Trendline 50 L Trendline 100 L Trendline 150 L

Nominal Capacity (L) 50 100 150

Installation HOR HOR / VERT HOR / VERT

Mounting wall / floor wall / floor wall / floor

Max Working Pressure (kPa) 600 600 600

Heating Element Spiral Spiral Spiral

Power (kW) 2 2 3

Voltage (V) 230 230 230

IPX Rating IPX4 IPX4 IPX4

Max Working Temperature (°C) 70 70 70

External Diameter (mm) 460 460 460

Prod Depth (mm) 550 940 1330

Prod Height (mm) 490 490 490

Weight (kg) 24 34 44

Insulation Thickness (mm) 22.5 22.5 22.5

Insulation Type Polyurethane Polyurethane Polyurethane

Standing Heat loss (kWh/24h) 1.62 2.16 2.59

Safety Valve (kPa) 600 600 600

Other Accessories Safety Valve & Drain Cock Safety Valve & Drain Cock Safety Valve & Drain Cock

Inlet/Outlet Connection Sizes 3/4” (Female) 3/4” (Female) 3/4” (Female)

Inlet/Outlet Connection Distance (mm) 260 700 1100

Anode Type Magnesium Magnesium Magnesium

Anode Dimensions 20x400 20x600 20x850

2YEARWARRANTY*

Warranty on the TP Valve

andDrain Cock

1YEARWARRANTY*

Warrantyon the Electric

Components

Warranty on the Inner

Cylinder 5YEARWARRANTY*

Heat Pump& Solar

Compatible600kPaTHICK INNERSTEEL TANK

2mm 5YEARWARRANTY*

Page 6: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

10 | www.heattech.co.za www.heattech.co.za | 11

HighlineGeysers

Description Highline 200 L Highline 250 L

Nominal Capacity (L) 200 250

Installation HOR / VERT HOR

Mounting Floor Floor

Max Working Pressure (kPa) 600 400

Heating Element Spiral Spiral

Power (kW) 3 4

Voltage (V) 230 230

IPX Rating IPX4 IPX4

Max Working Temperature (°C) 70 70

External Diameter (mm) 525 525

Prod Depth (mm) 1340 1630

Prod Height (mm) 540 540

Weight (kg) 49 58

Insulation Thickness (mm) 25 25

Insulation Type Polyurethane Polyurethane

Standing Heat loss (kWh/24h) 3.02 3.46

Safety Valve (kPa) 600 400

Other Accessories Safety Valve & Drain Cock Safety Valve & Drain Cock

Inlet/Outlet Connection Sizes 3/4” (Female) 3/4” (Female)

Inlet/Outlet Connection Distance (mm) 1090 1360

Anode Type Magnesium Magnesium

Anode Dimensions 20x1000 20x1000 & 20x400

Heat Pump& Solar

Compatible600kPaTHICK INNERSTEEL TANK

2mm

2YEARWARRANTY*

Warranty on the TP Valve

andDrain Cock

1YEARWARRANTY*

Warrantyon the Electric

Components

Warranty on the Inner

Cylinder 5YEARWARRANTY*

5YEARWARRANTY*

Stopcock

Mains Pressure

Balanced Cold Water

Pressure Control Valve

Drain Cock *Drip Tray

Vacuum Breaker Vacuum BreakerAnti - Siphon Loop

Above Top of Water Heater

Electrical Cover

Optional AnodeHeat Pump/SolarConnection or Plug*

Hot WaterOutlet

200 mm

300

mm

(MIN)

Safety Valve

300

mm

Stopcock

Mains Pressure

Safety Valve

Pressure Control Valve

Balanced Cold Water

Drain Cock *

Electrical Cover

Drip Tray

Hot WaterOutlet

300

mm

Optional AnodeHeat Pump/SolarConnection or Plug*

Anti - Siphon LoopAbove Top of Water Heater 30

0 m

m

Vacuum BreakerVacuum Breaker

Page 7: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

12 | www.heattech.co.za www.heattech.co.za | 13

5YEARWARRANTY*

400kPaTHICK INNERSTEEL TANK

2mm Heat PumpCompatible

Page 8: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

14 | www.heattech.co.za www.heattech.co.za | 15

CLOSED SYHPON SYSTEM

SPLITSYHPON SYSTEM

CAPACITY: 100 L• Indirect thermo system• Heat pump compatible• 400 kPa (high pressure)• Hot water regardless of the weather

1 x 5 L pre-mixed transfer fluid

Geyser solar 100

1.5 m² Universal Solar panel

Solar installation kit• Tempering valve• 400 kPa T&P valve• Solar relief valve• Drain cock

1

3

4

2

CLOSED SYHPON SYSTEM

SPLITSYHPON SYSTEM

CAPACITY: 150 L• Indirect thermo system• Heat pump compatible• 400 kPa (high pressure)• Hot water regardless of the weather

1 x 5 L pre-mixed transfer fluid

Geyser solar 150

1 x 2 m² Universal Solar panel

Solar installation kit• Tempering valve• 400 kPa T&P valve• Solar relief valve• Drain cock

1

3

4

2

WATER INLET

WATER OUTLET

CAPACITY: 200 L• Indirect thermo system• Heat pump compatible• 400 kPa (high pressure)• Hot water regardless of the weather

2 x 5 L pre-mixed transfer fluid

Geyser solar 200

2 x 1.5 m² Universal Solar panelSolar installation kit• Tempering valve• 400 kPa T&P valve• Solar relief valve• Drain cock

3

4

2

1

CLOSED SYHPON SYSTEM

SPLITSYHPON SYSTEM

2YEARWARRANTY*

Warranty on the TP Valve

andDrain Cock

1YEARWARRANTY*

Warrantyon theElectric

Components

Warranty on the Inner

Cylinder 5YEARWARRANTY*

400kPa400kPa400kPa

5YEARWARRANTY*

400kPaTHICK INNERSTEEL TANK

2mm Heat PumpCompatible

Page 9: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

16 | www.heattech.co.za www.heattech.co.za | 17

SolarlineSolar Geysers

3

2

1

1

Description Solarline 100 L Geyser Solarline 150 L Geyser Solarline 200 L Geyser

Nominal capacity (ltrs.) 100 150 200

IPX Rating IPX4 IPX4 IPX4

Max Working Temperature (°C) 70 70 70

External Diameter (mm) 525 525 525

Prod Depth (mm) 930 1300 1680

Prod Height (mm) 550 550 550

Weight (kg) 38.5 53 69

Insulation Thickness (mm) 50 50 50

Insulation Type Polyurethane Polyurethane Polyurethane

Energy Rating 11.4 MJ/day 17.8 MJ/day 24.5 MJ/day

Standing Heat loss (kWh/24h) 1.21 1.94 2.26

Safety Valve (kPa) 400 400 400

Other AccessoriesSafety Valve & Drain Cock

100kPa Relief Valve, Tempering Valve, 5L Glycol

Safety Valve & Drain Cock 100kPa Relief Valve, Tempering

Valve, 5L Glycol

Safety Valve & Drain Cock 100kPa Relief Valve, Tempering

Valve, 5L Glycol

Inlet/Outlet Connection Sizes 3/4” (Female) 3/4” (Female) 3/4” (Female)

Inlet/Outlet Connection Distance (mm) 720 1100 1470

Anode Type Magnesium Magnesium Magnesium

Anode Dimensions 20x600 20x850 20x1000

System Properties Solar Water Heater Solar Water Heater Solar Water Heater

Heat Exchanger Double Jacket Double Jacket Double Jacket

Thermal Transfer Process Thermosyphon Action Thermosyphon Action Thermosyphon Action

Collector Aperture Area (net) 1.5 2 2x1.5 (3m)

Resistance to Hail Yes Yes Yes

Resistance to Freezing Yes Yes Yes

Collector Hail Cover Unnecessary Unnecessary Unnecessary

Fluid Channel Material Copper Copper Copper

Closed-loop Transfer FluidPropylene Glycol / Glycol

Mixure of no less than 30% to total closed-loop volume

Propylene Glycol / Glycol Mixure of no less than 30% to

total closed-loop volume

Propylene Glycol / Glycol Mixure of no less than 30% to

total closed-loop volume

Anti freeze glycol

2

5YEARWARRANTY*

400kPaTHICK INNERSTEEL TANK

2mm Heat PumpCompatible

Page 10: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

18 | www.heattech.co.za www.heattech.co.za | 19

Page 11: 2 |   | 3 · 2 year warranty* 1 year warranty* joint acceptance scheme for water services installation components certificate of acceptance ... heat tech highline 100

SANS 151