![Page 2: 19“-meSSSySTem 19“-MeasureMent systeM · 2018. 8. 22. · Wir machen IhreSysteme präzise, zuverlässig, hochwertig. Junkersring 23 53844 Troisdorf Germany Telefon: +49 (0) 2241](https://reader035.vdocuments.us/reader035/viewer/2022071609/6148c3f02918e2056c22e69b/html5/thumbnails/2.jpg)
µCAN.x.ti-19“µNET.x.ti-19“
µCAN.x.ai-19“µNET.x.ai-19“
µCAN.x.ao-19“µNET.x.ao-19“
µCAN.x.dio-19“µNET.x.dio-19“
µCAN.x.ci-19“µNET.x.ci-19“
µCAN.x.pwm-19“ µNET.x.pwm-19“
Schnittstelle / Interface can / ethercaT can / ethercaT can / ethercaT can / ethercaT can / ethercaT can / ethercaT
E/A pro Modul / I/O per module 8 / 16 8 / 16 8 / 16 8 / 16 8 / 16 8 / 16
Signalart / signal type Temperature input analogue input analogue Output Digital i/0 counter input PWm Out
+/- 10 V 0(4)-20 ma --- --- --- --- ---
DMS / strain Gauge --- --- --- --- --- --- --- --- ---
Thermo / th.couple Pt 100 --- --- --- --- --- --- ---
Digital i/O --- --- --- hS / LS Driver hS / LS input hS / LS Driver
Zählersignal / Counter --- --- --- --- 1 hz - 500 khz ---
Messfehler / accuracy +/-0,1K 0,01% full scale 0,01% full scale --- +/- 0,1 hz 0,5% Steps
Auflösung / resolution 16-bit / 24-bit 16-bit / 24-bit 16-bit --- 0,1 hz 0% - 100%
Wandlungszeit / sample rate 5 ms 5 ms 5 ms 1 ms 100 ms 25 hz – 5 khz Base
Versorgungsspannung / supply Voltage 9 - 36 V Dc 9 - 36 V Dc 9 - 36 V Dc 8 - 50 V Dc 8 - 50 V Dc 8 - 50 V Dc
Betriebstemperatur / ambient temperature -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c
Die µLAB-Produktreihe ist für die industrielle und experimentelle Prüftechnik konzipiert. Das System ist besonders geeignet für das Messen von elektrischen, thermischen und mechanischen Größen in Motor- und Komponentenprüfständen. Messsysteme in standardi-sierten Gehäuseformen mit einer Höheneinheit sind typischerweise in industriellen Prüfeinrichtungen zu finden.
Systeme in 19“-Technik bieten eine hohe Packungsdichte, Flexibilität in der Anschlusstechnik sowie die Kombinationsmöglichkeit z. B. mit Bedien- und Anzeigeterminals.
The µLAB-series is designed for a wide range of industrial and experimen-tal research tasks. Highly efficient electronics and versatile functionality make the µLAB-series the perfect system for use in research and engine test bench environments. Measurement systems with the standard size of 1 height unit are typically found in industrial test facilities.
Systems in 19“-technology offer high packing density, flexibility for con-nection equipment as well as the possibility of combining with products from other suppliers.
TechniSche DaTen / teChnICal data
19“-meSSSySTem
19“-MeasureMent systeM
![Page 3: 19“-meSSSySTem 19“-MeasureMent systeM · 2018. 8. 22. · Wir machen IhreSysteme präzise, zuverlässig, hochwertig. Junkersring 23 53844 Troisdorf Germany Telefon: +49 (0) 2241](https://reader035.vdocuments.us/reader035/viewer/2022071609/6148c3f02918e2056c22e69b/html5/thumbnails/3.jpg)
µCAN.x.ti-19“µNET.x.ti-19“
µCAN.x.ai-19“µNET.x.ai-19“
µCAN.x.ao-19“µNET.x.ao-19“
µCAN.x.dio-19“µNET.x.dio-19“
µCAN.x.ci-19“µNET.x.ci-19“
µCAN.x.pwm-19“ µNET.x.pwm-19“
Schnittstelle / Interface can / ethercaT can / ethercaT can / ethercaT can / ethercaT can / ethercaT can / ethercaT
E/A pro Modul / I/O per module 8 / 16 8 / 16 8 / 16 8 / 16 8 / 16 8 / 16
Signalart / signal type Temperature input analogue input analogue Output Digital i/0 counter input PWm Out
+/- 10 V 0(4)-20 ma --- --- --- --- ---
DMS / strain Gauge --- --- --- --- --- --- --- --- ---
Thermo / th.couple Pt 100 --- --- --- --- --- --- ---
Digital i/O --- --- --- hS / LS Driver hS / LS input hS / LS Driver
Zählersignal / Counter --- --- --- --- 1 hz - 500 khz ---
Messfehler / accuracy +/-0,1K 0,01% full scale 0,01% full scale --- +/- 0,1 hz 0,5% Steps
Auflösung / resolution 16-bit / 24-bit 16-bit / 24-bit 16-bit --- 0,1 hz 0% - 100%
Wandlungszeit / sample rate 5 ms 5 ms 5 ms 1 ms 100 ms 25 hz – 5 khz Base
Versorgungsspannung / supply Voltage 9 - 36 V Dc 9 - 36 V Dc 9 - 36 V Dc 8 - 50 V Dc 8 - 50 V Dc 8 - 50 V Dc
Betriebstemperatur / ambient temperature -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c -40°c / +85°c
AnschlussmöglichkeitDie Zuführung aller Signale erfolgt über steckbare aus-führungen. Die Stecker werden nach ihren Vorstellungen ausgewählt.
CANDie Systeme sind mit einer high-Speed can-Schnittstelle ausgestattet. Die Protokolle canopen und raw-can werden unterstützt.
EtherCATals neuer Standard in der messtechnik sind die module auch mit einer ethercaT-Schnittstelle (coe) verfügbar.
Fittingsupply of signal and fieldbus chains is significantly simplified by use of connectors. a wide variety of connectors and customer specific solutions are also available for maximum flexibility.
CANthe modules are equipped with a highspeed Can interface supporting Can 2.0a and Can 2.0B. higher layer protocols such as Canopen, raw Can and many customer specific protocols are also supported.
EtherCATthe new etherCat interface is state-of-the-art measurement technology. the modules can be equipped with an etherCat (Coe) interface.
Tech
nis
che
Än
der
ung
en v
orb
ehal
ten
.C
hang
es w
itho
ut n
otic
e.
![Page 4: 19“-meSSSySTem 19“-MeasureMent systeM · 2018. 8. 22. · Wir machen IhreSysteme präzise, zuverlässig, hochwertig. Junkersring 23 53844 Troisdorf Germany Telefon: +49 (0) 2241](https://reader035.vdocuments.us/reader035/viewer/2022071609/6148c3f02918e2056c22e69b/html5/thumbnails/4.jpg)
Wir machen Ihre Systemepräzise, zuverlässig, hochwertig.
Junkersring 23 53844 TroisdorfGermany
Telefon: +49 (0) 2241 / 25 65 9 - 0Telefax: +49 (0) 2241 / 25 65 9 - 11
[email protected]. microcontrol.net
Individuelle Sonderanfertigungen: Schon unsere bewährten Stan-dardprodukte lösen die meisten Aufgaben in zuverlässiger Art und Weise.Gern fertigen wir auch für Sie Sonderbauformen, individuelleAnschlussmöglichkeiten oder zusätzliche Funktionalitäten für unsere 19“-Messsysteme.Bitte fragen Sie uns!
Customer specific solutions:Our well-established µCAN family has proven to work reliably in a wide range of applications.
We would be pleased to develop custom-made components, individual connections or additional functions to our rail modules with you. Please contact us !
Wir machen ihre SySTemepräzise, zuverlässig, hochwertig.
madein
Germany