1800 change of standard

38
Change of Standard EPLAN Training 1 Change of Standard

Upload: sorinbut

Post on 18-Jan-2016

216 views

Category:

Documents


1 download

DESCRIPTION

800 Change of standard.pdf

TRANSCRIPT

Page 1: 1800 Change of Standard

Change of Standard

EPLAN Training 1

Change of Standard

Page 2: 1800 Change of Standard

Change of Standard

EPLAN Training 2

1 Setting up the Target Project - Changing Standards.................................3

2 Specifying the Template and Rotation / Mirroring Scheme - Changing Standards ......................................................................................................6

3 Creating Rotation / Mirroring Schemes - Changing Standards ................9

4 Replacing Plot Frames, Forms, and Function Definition Libraries - Changing Standards...................................................................................11

5 Replacing Symbol Libraries and Symbols - Changing Standards .........13

5.1 Assign target symbol libraries .................................................................13

6 Creating Allocation Schemes for Symbols...............................................18

6.1 Create a scheme.....................................................................................18

6.2 Select source and target symbol library ..................................................20

6.2.1Enter and assign source and target symbols automatically ................... 22

6.2.2Enter and assign source and target symbols manually.......................... 26

7 Defining the Project Structure - Changing Standards .............................33

8 Defining Device Numbering - Changing Standards .................................36

This functionality is only available for certain module packages. Info

Page 3: 1800 Change of Standard

Change of Standard

EPLAN Training 3

1 Setting up the Target Project - Changing Standards

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have a template containing country- or standards-specific settings.

Utilities > Change of standard

1. Specify a recognizable project name without file name extension in the Target Project Name field of the Project tab.

Page 4: 1800 Change of Standard

Change of Standard

EPLAN Training 4

2. Click [...] next to the Storage location field to select a location for the project.

3. In the Find folder dialog select the directory where you want to save the new project and click [OK].

Page 5: 1800 Change of Standard

Change of Standard

EPLAN Training 5

4. Click [Next].

Specify the template and rotation / mirroring scheme

This functionality is only available for certain module packages. Info

Page 6: 1800 Change of Standard

Change of Standard

EPLAN Training 6

2 Specifying the Template and Rotation / Mirroring Scheme - Changing Standards

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have a template containing country- or standards-specific settings.

• You have set up a target project.

Utilities > Change of standard

1. To specify a template for the target project, use [...] on the Rotation / Mirroring tab to select a project template *.ept .

Page 7: 1800 Change of Standard

Change of Standard

EPLAN Training 7

2. From the Rotation / Mirroring drop-down list, select the way in which you want to rotate and mirror.

3. Click [Next].

Replacing Plot Frames, Forms and Function Definition Libraries

Page 8: 1800 Change of Standard

Change of Standard

EPLAN Training 8

This functionality is only available for certain module packages. Info

Page 9: 1800 Change of Standard

Change of Standard

EPLAN Training 9

3 Creating Rotation / Mirroring Schemes - Changing Standards

The rotation / mirroring scheme determines how the schematic elements are rotated and mirrored. Symbols are rotated in their configuration on the schematic. Text elements and special texts are rotated in their configuration on the schematic as well as within themselves.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

Utilities > Change of standard > Project tab > [Next]

1. To create a rotation / mirroring scheme, go to the Rotation / mirroring tab and click [...] next to the Rotation / mirroring field.

2. In the Settings: Rotation / Mirroring dialog click (New).

3. In the New scheme dialog enter a recognizable name and a descriptive text for the scheme in the Description field and click [OK].

In the Settings: Rotation / mirroring dialog the new scheme is now available as a user-defined scheme in the Scheme drop-down list.

4. From the Rotate drop-down list select the number of degrees the schematic elements should rotate in their configuration in the schematic.

5. To mirror the configuration of the schematic elements on the page, select the Mirror check box.

Page 10: 1800 Change of Standard

Change of Standard

EPLAN Training 10

6. Click (Save) and then click [OK].

This functionality is only available for certain module packages. Info

Page 11: 1800 Change of Standard

Change of Standard

EPLAN Training 11

4 Replacing Plot Frames, Forms, and Function Definition Libraries - Changing Standards

To adjust a project to a different standard you can replace existing plot frames and forms with different ones.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

• You have specified template and rotation / mirroring schemes.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring tab > [Next]

1. In the Master data tab in the Name column, select a form, a plot frame, or a function definition library to be replaced.

Page 12: 1800 Change of Standard

Change of Standard

EPLAN Training 12

2. Within the same row, click [...] in the New name column.

3. In the following dialog select the form, the plot frame, or the function definition library to be used for the target project and click [Open].

The selected file is entered in the New name column.

Next, you can replace symbol libraries and symbols.

This functionality is only available for certain module packages. Info

Page 13: 1800 Change of Standard

Change of Standard

EPLAN Training 13

5 Replacing Symbol Libraries and Symbols - Changing Standards

You can replace basic symbol libraries, symbol libraries, and individual symbols. The basic symbol library contains the symbols for the basic symbol preview. When exchanging the basic symbol libraries and symbol libraries, the source data is saved in the target project. Individual symbols are replaced there.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

• You have specified template and rotation / mirroring schemes.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring tab > [Next]

5.1 Assign target symbol libraries

1. In the Master data tab in the Name column select the symbol library to be replaced.

Page 14: 1800 Change of Standard

Change of Standard

EPLAN Training 14

2. Within the same row, click [...] in the New name column.

3. In the Select Symbol Library dialog, select the symbol library to be used for the target project and click [Open].

The symbol library is entered in the New Name column.

Page 15: 1800 Change of Standard

Change of Standard

EPLAN Training 15

4. To assign the entire symbol library click [Next] in the Master data tab and do the same in the Symbols tab.

Defining the Project Structure.

Page 16: 1800 Change of Standard

Change of Standard

EPLAN Training 16

5. To assign the source symbol library symbols to the target symbol library symbols, select the Individual assignment check box in the Master data tab and click [Next].

The source and target symbol libraries are entered in the Symbols tab.

6. In the Symbols tab in the Scheme column select an assignment scheme.

If you do not want to use an existing assignment scheme, click [Scheme] and create your own assignment scheme.

Page 17: 1800 Change of Standard

Change of Standard

EPLAN Training 17

7. Click [Next].

Defining the Project Structure.

This functionality is only available for certain module packages. Info

Page 18: 1800 Change of Standard

Change of Standard

EPLAN Training 18

6 Creating Allocation Schemes for Symbols

In the assignment scheme assign the symbols from the target symbol library to the symbols of the source symbol library. When changing standards the symbols of the source symbol library are replaced by the symbols of the target symbol library.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

• You have replaced the necessary forms and plot frames.

• You have selected a target symbol library in the Master data tab and selected the Individual assignment check box.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring tab > [Next] > Master data tab > [Next]

6.1 Create a scheme

1. Click [Schemes] in the Symbols tab.

Page 19: 1800 Change of Standard

Change of Standard

EPLAN Training 19

2. In the dialog Settings: Symbol assignment dialog, in the Scheme field,

select the scheme you want to edit or click and create a scheme.

Page 20: 1800 Change of Standard

Change of Standard

EPLAN Training 20

6.2 Select source and target symbol library

1. Select [Extras] > Select source and target symbol library.

Page 21: 1800 Change of Standard

Change of Standard

EPLAN Training 21

2. In the Select Source Symbol Library dialog select the symbol library you want to create for the assignment and click [OK].

3. In the Select Target Symbol Library dialog select the symbol library you want to create for the assignment and click [OK].

Page 22: 1800 Change of Standard

Change of Standard

EPLAN Training 22

6.2.1 Enter and assign source and target symbols automatically

1. Select [Extras] > Enter source symbols automatically. All symbols from the source symbol library are entered in the Assign

symbols table.

Page 23: 1800 Change of Standard

Change of Standard

EPLAN Training 23

2. Select [Extras] > Suggest matching target symbols.

The symbols from the selected target symbol library are entered in the Assign symbols table and assigned to source symbols.

Page 24: 1800 Change of Standard

Change of Standard

EPLAN Training 24

3. Check the symbol assignments.

If EPLAN finds suitable symbols then the status changes to "OK" .

Page 25: 1800 Change of Standard

Change of Standard

EPLAN Training 25

4. Click (Save) and then click [OK].

The scheme is entered into the Symbols tab.

Page 26: 1800 Change of Standard

Change of Standard

EPLAN Training 26

5. Click [Next].

Defining the Project Structure.

6.2.2 Enter and assign source and target symbols manually

Precondition:

You have selected source and target libraries.

Page 27: 1800 Change of Standard

Change of Standard

EPLAN Training 27

1. In the Settings: Symbol Assignment dialog, click next to the Assign Symbols field on (New).

In the Assign Symbols table an empty row is inserted.

Page 28: 1800 Change of Standard

Change of Standard

EPLAN Training 28

2. Click in the Source Symbol Name column.

The source symbol library opens in the Symbol selection dialog.

3. Select a symbol and click [OK].

Page 29: 1800 Change of Standard

Change of Standard

EPLAN Training 29

4. Click in the Target Symbol Name column in the Settings: Assign Symbols tab.

The target symbol library opens in the Symbol selection dialog.

Page 30: 1800 Change of Standard

Change of Standard

EPLAN Training 30

5. Select a suitable symbol and click [OK].

The assignment of symbols is checked.

6. Assign other symbols in the same way.

Page 31: 1800 Change of Standard

Change of Standard

EPLAN Training 31

7. Click (Save) and then click [OK].

The scheme is entered into the Symbols tab.

Page 32: 1800 Change of Standard

Change of Standard

EPLAN Training 32

8. Click [Next].

Defining the Project Structure.

This functionality is only available for certain module packages. Info

Page 33: 1800 Change of Standard

Change of Standard

EPLAN Training 33

7 Defining the Project Structure - Changing Standards

User-defined and existing schemes for page and device structure are taken from the template that you specified when creating the target project.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

• You have specified template and rotation / mirroring schemes.

• You have replaced the necessary plot frame, forms, symbol libraries, and symbols.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring tab > [Next] > Master data tab > [Next]

1. To change the page structure, select an identifier scheme for the page structure from the Pages drop-down list in the Structure tab.

Page 34: 1800 Change of Standard

Change of Standard

EPLAN Training 34

2. To change separators click [...] next to Separator and specify the desired separator in the Extended Project Structures dialog.

3. To change the identifier schema for devices, select an identifier scheme in the corresponding drop-down list.

Page 35: 1800 Change of Standard

Change of Standard

EPLAN Training 35

4. Click [Next].

Specifying Device Numbering.

This functionality is only available for certain module packages. Info

Page 36: 1800 Change of Standard

Change of Standard

EPLAN Training 36

8 Defining Device Numbering - Changing Standards

User-defined and existing schemes for device numbering are taken from the template that you specified when creating the target project.

Preconditions:

• You have opened a project.

• If multiple projects are open: You have selected a project in the page navigator.

• You have set up a target project.

• You have specified template and rotation / mirroring schemes.

• You have replaced the necessary plot frame, forms, symbol libraries, and symbols.

• You have specified the project structure.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring tab > [Next] > Master data tab > [Next] > Structure tab > [Next]

1. In the Number tab select the Number Device check box.

Page 37: 1800 Change of Standard

Change of Standard

EPLAN Training 37

2. Select a numbering format from the Device Numbering drop-down list.

3. Click [Make available].

The page description is displayed in the page navigator.

Page 38: 1800 Change of Standard

Change of Standard

EPLAN Training 38