c usUL RecognizedFile No. E13224
GENERALGENERAL SPECIFICA SPECIFICATIONSTIONS
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONALELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATIONPERFORMED BY THE UNDERWRITERSLABORATORIES AS A THIRD PARTYPARTICIPANT
*
*
*
168986
SPDT, DPDT & 3PDT, 15 AMPS
UL CONTACT LOAD RATINGS TABLE
POLES
1 POLETHRU
3 POLES
CURRENT OR
HORSE POWER
15 AMP
10 AMP
1/3 HP
1/2 HP
3 AMP
LOAD
VOLTAGE
120/240 VAC
28 VDC
120 VAC
240 VAC
600 VAC
LOAD VOLTAGE
FREQUENCY
50/60 Hz
DC
50/60 Hz
50/60 Hz
50/60 Hz
TYPE OF
LOAD
RESISTIVE
RESISTIVE
MOTOR
MOTOR
RESISTIVE
Mating Sockets70-463-1: SCREW/DIN70-124-1: SOLDER70-178-1, 70-178-2: PRINTED CIRCUIT70-124-2: QUICK CONNECTSee section 8, page 16, 17
COILPull-in Voltage:
Dropout Voltage: Max. Voltage: Resistance: Coil Power:
Insulation System: Maximum Coil Dissipation: Duty:
CONTACTS Contact Material: Contact Resistance:
Contact Ratings:
DIELECTRIC STRENGTH Contacts to Coil: Across Open Contacts: Pole to Pole Contacts to Frame: Insulation Resistance:
TEMPERATURE Operating: Storage
LIFE EXPECTANCY Electrical: Mechanical:
MISCELLANEOUS Operating Position: Insulation material: Enclosure: Terminals:
Weight:
80% of nominal voltage or less for DC coils85% of nominal voltage or less for AC coils10% of nominal voltage or more110% 10 % measured at 25˚C
1.2 watts for DC coils,2 VA to 2.75 VA for AC @ 25˚CClass “B” (130˚C per UL standard 1446)3.0 watts max. DCContinuous
0.187 silver alloy, gold flashed50 milliohms maximum initial resistanceat rated currentSee “UL CONTACT LOAD RATINGS TABLE”
2000 V rms500 V rms2000 V rms2000 V rms1000 megohms @ 500 VDC
-30˚C to +50˚C. (AC), -30˚C to +65˚C. (DC)-30˚C to +100˚C
100,000 operations @ rated resistive load5,000,000 operations @ no load
AnyMolded plasticPolycarbonate dust cover0.187 x 0.032 quick connect flange or 0.187 x 0.020solder/plug-in. Optional printed circuit terminals available88 grams approx.
MANUFACTURED UNDER
ISO 9002 & QS 9000
OPTIONAL PRINTED CIRCUITTERMINAL CONSULT FACTORY.
OPTIONAL TOP FLANGECOVER CONSULT FACTORY.
OPTIONAL DIN COVERCONSULT FACTORY.
FLANGE MOUNT
PLUG-IN
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: [email protected]
A283 PLUG-IN & FLANGE MOUNT RELAY
LISTED 367GIND. CONT. EQ.
C USWHEN USED WITHSOCKETS 70-463-1
CURRENT LIMITED TORATING OF RELAY ORSOCKET WHICHEVERIS LESS
OUTLINE DIMENSIONSDIMENSIONS SHOWN IN INCHES & (MILLIMETERS).
QUICK CONNECT SOLDER / PLUG-IN TERMINALS
1.40(35.5)
1.53 MAX.(38.8)
1.53 MAX.(38.8)
1.90 MAX.(48.4)
1
B
9
3
6
7
4
A
2
8
5
0.187(4.749)
SPDT, DPDT & 3PDT, 15 AMPS
0.020(0.508)
RETROFITS POTTER & BRUMFIELD KUP.SEE END OF SECTION 1 FOR CROSS REFERENCE
A283XAXC-120A
A283XAXC-240A
A283XBXC-24A
A283XBXC-120A
A283XBXC-240A
A283XCXC-24A
A283XCXC-120A
A283XCXC-240A
A283XAXC-12D
A283XAXC-24D
A283XBXC-12D
A283XBXC-24D
A283XBXC-110D
A283XCXC-12D
A283XCXC-24D
SPDT
SPDT
DPDT
DPDT
DPDT
3PDT
3PDT
3PDT
SPDT
SPDT
DPDT
DPDT
DPDT
3PDT
3PDT
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
24 VAC, 50/60Hz
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
24 VAC, 50/60Hz
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
12 VDC
24 VDC
12 VDC
24 VDC
110 VDC
12 VDC
24VDC
2250
9100
75
2250
9100
72
1700
7200
120
472
120
472
10,000
120
472
1 2 3
4 5 6
7 8 9
A B
1 3
4 6
7 9
A B
1 2 3
4 5 6
7 8 9
A B
(VIEWED FROM PIN END)
A283 PLUG-IN RELAY
AC OPERATED SOLDER/PLUG-IN, 15 AMP
DC OPERATED SOLDER/PLUG-IN, 15 AMP
OUTLINE DIMENSIONSDIMENSIONS SHOWN IN INCHES & (MILLIMETERS).
QUICK CONNECT SOLDER / PLUG-IN TERMINALS
1.40(35.5)
1.53 MAX.(38.8)
1
B
9
3
6
7
4
A
2
8
5
SPDT, DPDT & 3PDT, 15 AMPS
0.032( 0.891)
1.53 MAX.(38.8)
0.187(4.749)
1.90 MAX.(48.4)
0.156(3.9)
2.50 MAX.(63.5)
2.90 MAX.(73.8)
RETROFITS POTTER & BRUMFIELD KUP.SEE END OF SECTION 1 FOR CROSS REFERENCE
A283XAXC1-120A
A283XAXC1-240A
A283XBXC1-120A
A283XBXC1-240A
A283XCXC1-120A
A283XCXC1-240A
A283XAXC1-12D
A283XAXC1-24D
A283XBXC1-12D
A283XBXC1-24D
A283XCXC1-24D
SPDT
SPDT
DPDT
DPDT
3PDT
3PDT
SPDT
SPDT
DPDT
DPDT
3PDT
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
120 VAC, 50/60Hz
220/240 VAC, 50/60Hz
12 VDC
24 VDC
12 VDC
24 VDC
24 VDC
2250
9100
2250
9100
1700
7200
120
472
120
472
472
1 2 3
4 5 6
7 8 9
A B
1 2 3
4 5 6
7 8 9
A B
1 3
4 6
7 9
A B
(VIEWED FROM PIN END)
A283 FLANGE MOUNT RELAY
AC OPERATED, 15 AMP
DC OPERATED, 15 AMP
OUTLINE DIMENSIONSDIMENSIONS SHOWN IN INCHES & (MILLIMETERS).
QUICK CONNECT SOLDER / PLUG-IN TERMINALS
1.40(35.5)
1.53 MAX.(38.8)
1.53 MAX.(38.8)
1.90 MAX.(48.4)
1
B
9
3
6
7
4
A
0.187(4.749)
DPDT , DPST-NO, SPST-NO-DM,SPDT-NO-DM -DB & SPST-NO-DM,
3 & 10 AMPS, 150 VDC SWITCHING
UL CONTACT LOAD RATINGS TABLE FOR DC SWITCHING
POLES
DPDT
SPST(DM and/or DB)
SPST(N.O or N.C)
CURRENT OR
HORSE POWER
3 AMP
10 AMP
10 AMP
LOAD
VOLTAGE
150 VDC
150 VDC
150 VDC
TYPE OF
LOAD
RESISTIVE
RESISTIVE
RESISTIVE
0.020(0.508)
BLOWOUT MAGNET
STANDARD FEATURE
THE BLOWOUT MAGNET
STYLES HAVE THE SAME
LOAD SPECIFICATIONS
AS THE A283 ENCLOSED
PLUG-IN RELAYS, PLUS
THE ADDITIONAL LOAD
RATINGS CHARTED IN
TABLE ABOVE.
SEE A283 GENERAL
SPECIFICATIONS.
A283XBX69C-120A
A283XBX69C-12D
A283XBX69C-24D
A283XBX69C-110D
A283HXX69C-120A
A283XHX69C-48D
A283BXX69C-24D
A283BXX69C-48D
A283HXX69C-12D
A283HXX69C-24D
A283HXX69C-48D
A283HXX69C-110D
DPDT
DPDT
DPDT
DPDT
SPST-NO (DM)
SPDT-NO (DM-DB)
DPST-NO
DPST-NO
SPST-NO (DM)
SPST-NO (DM)
SPST-NO (DM)
SPST-NO (DM)
2250
120
472
10,000
2250
1800
472
1800
120
472
1800
10,000
120 VAC, 50/60 Hz
12 VDC
24 VDC
110 VDC
120 VAC, 50/60 Hz
48 VDC
24 VDC
48 VDC
12 VDC
24 VDC
48 VDC
110 VDC
RETROFITS POTTER & BRUMFIELD KUEP.SEE END OF SECTION 1 FOR CROSS REFERENCE
1 3
4 6
7 9
A B
A B
4 6
(VIEWED FROM PIN END)
A283 PLUG-IN RELAY FOR DC SWITCHING
AC OPERATED WITH BLOWOUT MAGNET, 3 AMP
DC OPERATED WITH BLOWOUT MAGNET, 3 AMP
AC OPERATED WITH BLOWOUT MAGNET, 10 AMP
DC OPERATED WITH BLOWOUT MAGNET, 10 AMP
DC OPERATED WITH BLOWOUT MAGNET, 10 AMP
DC OPERATED WITH BLOWOUT MAGNET, 5 AMP