  • Technical Data

    Fluke 1630 Earth Ground Clamp Meter

    Awidegroundloopresistancerange,from0.025to1500,tosatisfyallrequirements

    Largejawopeningof35mm(1.38in)fortestsongroundconductorsand/orequipotentialbusbars

    Measurementofgroundleakagecurrent,from0.2mAto1000mA,withoutneedingtodisconnect-idealforsystemtroubleshooting

    Wideaccurrentmeasurementrangefrom0.2Ato30Aallowsoneinstrumentformultipleapplications

    Continuitylooptest-quicklyassesswhetherresistanceislessthan40,withaudiblealarm

    User-definedHI/LOAlarmlimits,forrapidmeasurementevaluation HandyDisplay-Holdbuttonforcapturingreadingsinhard-to-reachplaces

    Timesavingmemoryfunctionautomaticallyrecordsandstoresmeasuredvalues

    Automaticselfcalibrationensurescorrectmeasurementeverytime

    The clamp-on ground testing technique used by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage current measurement. The compact and rugged design makes the Fluke 1630 easy to use in small places and harsh environ-ments, while the Display-Hold and the continuity test-ing with an audible alarm function, ensures convenience in use. The novel technique means that earth ground loop testing and continuity testing can be completed without breaking the circuit.

    Earth Ground loop resistance measurements for commercial, industrial, and utility applications

  • 2FlukeCorporationFluke1630EarthGroundClampMeter

    Stakeless testing system

    TheFluke1630usestheStakelesstestingmethod,whicheliminatestheneedtodisconnectparallelgroundrodsandfindsuitablelocationsforplacingauxiliarygroundstakes.Thissavestimeandenablesuserssuchasindustrialandutilityelectricians,andfieldserviceelectriciansandcontractors,toperformearthgroundlooptestsinlocationswhereitisnotpossibletouseothertechniques,suchasinsidebuildingsoronpowerpylons.WiththeStakelesstestingmethod,earthgroundstakesarenolongernecessary.TheFluke1630EarthGroundClampisplacedaroundtheearthgroundrodortheconnectingcable.Aknownvoltageisinducedbyonehalfoftheclampandthecurrentismeasuredbytheotherhalf.Thetesterautomaticallydeterminesthegroundloopresistanceatthisgroundingconnection.

    Applications

    EarthGroundlooptestinginvariousinstallations-forexample,highvoltagepylons,buildings,cellphonesubstations,RFtransmitters,etc.

    Inspectionoflightningprotectionsystems Leakagecurrentmeasurement

    General specifications

    Operating error Referstotheoperatingtemperaturerangeandisguaranteedfor2years

    Storage temp. range -20Cto60C(-4Fto140F)Reference temp. range 23C5C(73F9F)Storage humidity

  • 3FlukeCorporationFluke1630EarthGroundClampMeter

    Ground Loop Resistance (Autorange) Operatingtemperature:0Cto50C(14Fto122F)

    Range Resolution Operating error1

    0.025-0.250 0.002 1.5%rdg0.050.250-9.999 0.02 1.5%rdg0.110.00-99.99 0.04 2.0%rdg0.3100.0-199.9 0.4 3.0%rdg1.0200.0-400.0 2 5.0%rdg5400.0-600.0 5 10%rdg10600.0-1500 20 20%

    1Note:Loopresistancewithnoinductance,externalmagneticfield