RUBIN MeiStream, MeiStream Plus Cold water
ApplicationsRUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are
designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply
management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement.
Features Wide measuring range
Measuring units can be replaced
Universal installation (MeiStream)
High overload capacity
Can be retrofitted with non-reactive modules for
remote readings
With MID approval
Your benefits Your benefits
Measuring both small and large volumes with one
flowmeter
MeiStream Plus is ideal for monitoring piping systems
and detecting pipe leaks
No straight inlet necessary for MeiStream
-
gL
hH
Range
Turbine meters with dry-type registers, IP 68 SVGW certification Type examination certificate according to Directive 2004/22 EC Powder-coated grey cast iron housing with flange connections acc. to EN 1092-1 Maximum temperature 50 C Nominal pressure PN 16 Replaceable measuring unit For updating with non-reactive HRI modules or optoelectronic pulsers
MeiStream: The meter can be installed in horizontal, vertical or inclined positions. The meter head must, however, face upwards or to the side. It requires no inlet path
The MeiStream Plus is for horizontal installation only and requires an inlet path of 3 x DN
RUBIN MeiStream
1) Flanges with 4 holes
2
Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94524 94525 94585 94526 94586 94527 94587Overload Q4 m3/h 60 90 90 120 120 200 200Nominal flowrate Q3 m3/h 40 50 50 70 70 120 120Transitional flowrate horizonal Q2 m3/h 0.32 0.4 0.4 0.63 0.63 0.51 0.51Transitional flowrate vertical Q2 m3/h 0.4 0.51 0.51 0.81 0.81 0.8 0.8Minimum flowrate horizontal Q1 m3/h 0.2 0.15 0.15 0.2 0.2 0.2 0.2Minimum flowrate vertical Q1 m3/h 0.25 0.28 0.28 0.4 0.4 0.5 0.5Starting flow at approx. m3/h 0.05 0.05 0.05 0.07 0.07 0.1 0.1Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5Recording capacity mio. m3 1 1 1 1 1 1 1Data for MID-homologationNominal flowrate Q3 m3/h 25 40 40 63 63 100 100Measuring range horizontal R 125 160 160 160 160 315 315Measuring range vertical R 63 100 100 100 100 125 125Measuring range as shown on delivery R 63 100 100 100 100 100 100Max. pressure loss at Q3 bar 0.08 0.18 0.18 0.37 0.37 0.16 0.16Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3Overall length
L 220 200 270 200 300 225 300H 120 120 120 120 120 150 150h 69 73 73 85 85 95 95g 200 200 200 200 200 270 270
-
gL
hH
3
Available on request:- Nominal pressure PN 40- Non-ferrous metal version- Version for use in explosion-proof areas- Flanged version e.g. ANSI, JIS
Nominal diameter DN mm 100 100 125 150 150inch 4 4 5 6 6
Art. No. 94528 94588 94529 94530 94589Overload Q4 m3/h 300 300 350 600 600Nominal flowrate Q3 m3/h 230 230 250 450 450Transitional flowrate horizonal Q2 m3/h 0.81 0.81 1.02 1.6 1.6Transitional flowrate vertical Q2 m3/h 1.28 1.28 1.6 3.2 3.2Minimum flowrate horizontal Q1 m3/h 0.3 0.3 0.5 0.8 0.8Minimum flowrate vertical Q1 m3/h 0.5 0.5 1 1.6 1.6Starting flow at approx. m3/h 0.11 0.11 0.15 0.3 0.3Smallest readable volume litre 0.5 0.5 0.5 5 5Recording capacity mio. m3 1 1 1 10 10Data for MID-homologationNominal flowrate Q3 m3/h 160 160 160 400 400Measuring range horizontal R 315 315 250 400 400Measuring range vertical R 160 160 125 200 200Measuring range as shown on delivery R 100 100 100 100 100Max. pressure loss at Q3 bar 0.34 0.34 0.2 0.32 0.32Weight kg 18.2 20.2 20.7 35.9 44.2Overall length
L 250 360 250 300 500H 150 150 160 177 177h 105 105 118 135 135g 270 270 280 356 356
-
gL
hH
4
RUBIN MeiStream Plus, improved measurement dynamics model, for horizontal installation only
1) Flanges with 4 holes
Available on request:- Version for use in explosion-proof areas
Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94534 94535 94590 94536 94591 94537 94592Overload Q4 m3/h 50 55 55 60 60 120 120Nominal flowrate Q3 m3/h 30 35 35 40 40 63 63Transitional flowrate horizonal Q2 m3/h 0.13 0.13 0.13 0.16 0.16 0.25 0.25Minimum flowrate horizontal Q1 m3/h 0.08 0.07 0.07 0.1 0.1 0.13 0.13Starting flow at approx. m3/h 0.03 0.03 0.03 0.04 0.04 0.04 0.04Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5Recording capacity mio. m3 1 1 1 1 1 1 1Data for MID-homologationNominal flowrate Q3 m3/h 25 25 25 40 40 63 63Measuring range horizontal R 315 315 315 400 400 400 400Measuring range as shown on delivery R 315 315 315 315 315 315 315Max. pressure loss at Q3 bar 0.09 0.08 0.08 0.17 0.17 0.07 0.07Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3Overall length
L 220 200 270 200 300 225 300H 120 120 120 120 120 150 150h 69 73 73 85 85 95 95g 200 200 200 200 200 270 270
g
L
hH
Nominal diameter DN mm 100 100 150 150inch 4 4 6 6
Art. No. 94538 94593 94539 94594Overload Q4 m3/h 160 160 400 400Nominal flowrate Q3 m3/h 100 100 250 250Transitional flowrate horizonal Q2 m3/h 0.4 0.4 0.63 0.63Minimum flowrate horizontal Q1 m3/h 0.2 0.2 0.35 0.35Starting flow at approx. m3/h 0.07 0.07 0.12 0.12Smallest readable volume litre 0.5 0.5 5 5Recording capacity mio. m3 1 1 10 10Data for MID-homologationNominal flowrate Q3 m3/h 100 100 250 250Measuring range horizontal R 400 400 630 630Measuring range as shown on delivery R 315 315 315 315Max. pressure loss at Q3 bar 0.16 0.16 0.14 0.14Weight kg 18.2 20.2 35.9 44.2Overall length
L 250 360 300 500H 150 150 177 177h 105 105 135 135g 270 270 356 356
-
5Roller counters
DN 40...125 DN 150
Pulsers
The Meistream / Meistream Plus large capacity water meters are designed to be used with non-reactive HR modules and optoelectronicpulsers. Add-ons can also be retrofitted without affecting the metrological data.
HRI modules 2 programmable pulse outputs and M-Bus data interface to
IEC870-5/EN1434-3 Non-reactive inductive tap with external manipulation detection Lifetime of battery approx. 12 years, external power supply via M-Bus or
auxiliary voltage 10...42 VDC approx. 15 years Cable length 3 m Ambient temperature -10 - 60 C, IP 68 Forward/reverse flow recognition Pulse value, length and type selectable with MiniCom software
M-Bus output, data transmission:- Meter reading- Instantaneous value- Fabrication number- Meter number with secondary address- Monthly meter reading on any day selected- Meter reading with current and previous years billing date selected- Minimum and maximum flowrate with time and date- Reverse flow volume with time and date- Pipe breakage and leak detection with selectable limit value- Detection of any attempt at external manipulation and broken cable
Pulse outputs:- Programmable as:
Opto-OD (NAMUR to EN 60947-5-6), pulse width 6 ms orOpen collector, pulse width 32, 128 or 500 ms, max. 48 VDC, max. 0.2 A, max. 4 Watt
m3
x 0,001
x 0,01
x 0,1
12
3456
7
89 0
12
3456
7
89 0
12
3456
7
89 0
OP
TO
x10m3
x 0,01
x 0,1
x 1
12
3456
7
89 0
12
3456
7
89
0
12
3456
7
89
OP
TO 0
Nominal diameter Minimum Display Smallest Pulse value Pulse valuescale value range pulse value with OD 01 with OD 03
with HRI-ModulDN 40...125 0.5 litre 1'000'000 m3 10 litres 1 litre 10 litreDN 150 5 litres 10'000'000 m3 100 litres 10 litres 100 litres
-
The following pulse modes can be set:
1) Reverse pulses are compensated by suppressing the identical number of forward pulses.2) Can be assigned for pipe breakage, leakage detection, external interference and cable breakage.
MiniCom software is required for changing set parameters.
The HRI-Mei pulser is available with the following parameters on request:
6
Pulse mode B1 B2 B3 B4 B5 B6Pulse outputI1 (white) Balanced Forward Forwards and Balanced NAMUR pulses NAMUR pulses with
pulses 1) pulses reverse pulses pulses 1) with forward/ blackflow suppres-reverse sion (OD-AM)recognition
I2 (yellow) On = Alarm 2) Reverse On = Forwards Off = Alarm 2) Not used Not usedpulses flow
Type designation Version Art. No.HRI-Mei/10/B4/D100/T500 DN 40...125: Open collector, 100 litres/pulse, pulse length 500 ms 80508HRI-Mei/10/B4/D1000/T500 DN 40...125: Open collector, 1000 litres/pulse, pulse length 500 ms 80616HRI-Mei/100/B4/D1000/T500 DN 150: Open collector, 1000 litres/pulse, pulse length 500 ms 80509HRI-Mei/10/B5/D10/T6 DN 40...125: NAMUR /EN 60947-5-6), 10 litres/pulse, pulse length 6 ms 80510HRI-Mei/100/B5/D100/T6 DN 150: NAMUR /EN 60947-5-6), 100 litres/pulse, pulse length 6 ms 80511HRI-Mei-CDL/10/D10/T6 DN 40...125: Forward/reverse pulse with plug for CDL data logger, 80512
10 litres/pulse, pulse length 6 msHRI-Mei-CDL/100/D100/T6 DN 150: Forward/reverse pulse with plug for CDL data logger, 80513
100 litres/pulse, pulse length 6 ms
Version DN 40...125 DN 150Open collector / NAMUR 0.01, 0.025, 0.05, 0.1 or 0.1, 0.25, 0.5, 1 or
0.25, 0.5, 1 m3/pulse 2.5, 5, 10 m3/pulsepulse mode B1 - B6 pulse mode B1 - B6pulse length 32, 128 or 500 ms pulse length 32, 128 or 500 mspulse length NAMUR 6 ms pulse length NAMUR 6 ms
-
7Configuration notes:The HRI-Mei impulse outputs are open collector outputs with no internal power limit which are galvanically connected to the M-Bus.
Typical application for connection to a PLS (programmable logic controller) with a power supply connected:
1) This connection is optional and taken over by the power supply for the HRI module. The service life of the internal battery increases to greater than 15 years.
Typical application for connection to a PLC (programmable logic controller) connected to earth:
1) This connection is optional and taken over by the power supply for the HRI module. The service life of the internal battery increases to greater than 15 years.
green
brown
white
yellow
grey
M -Bus
M -Bus
Impulse I1
Impulse I2
Ground
HRI-Mei
Ground
+ 24 V
Impulse input
1)
PLC
Ground
1 kOhm
green
brown
white
yellow
grey
M -Bus
M -Bus
Impulse I1
Impulse I 2
Ground
HRI-Mei
Ground
+ 24 V
Impulse input
1)
PLC
-
8Optoelectronic pulsers
IR reflex light barriers to EN 50227 as a plug-in version Non-reactive optical tap Cable length 3 m Ambient temperature -10 - 70 C, IP 68
Technical data:- Power supply 8.2 VDC- Switch current (actuated) 1.2 mA- Quiescent current (non-contact) 2.1 mA- Forwards and reverse flow detection is built in by means of an additional current threshold at 1.5 mA. With forward flow, the rising
pulse edge thus has an additional current threshold of 1.5 mA. With reverse flow, the current threshold lies on the falling edge of the pulse.Forward flow: Reverse flow:
- Pulse length is dependent on the flowrate and at meter standstill a continuous pulse is possible.
Standard pulse values and frequencies
MeiStream
MeiStream Plus
Type designation Version Art. No.OD 01 Optoelectronic pulser, smaller pulse value 93750OD 03 Optoelectronic pulser, larger pulse value 93752
Nominal diameter DN mm 40 50 65 80 100 125 150inch 1 1/2 2 2 1/2 3 4 5 6
OD 01 Pulse value litres/pulse 1 1 1 1 1 1 10Pulse frequency at Q4 Hz 16.7 25 33.3 55.7 83.3 97.2 16.7OD 03 Pulse value litres/pulse 10 10 10 10 10 10 100Pulse frequency at Q4 Hz 1.7 2.5 3.3 5.7 8.4 9.8 1.7
Nominal diameter DN mm 40 50 65 80 100 150inch 1 1/2 2 2 1/2 3 4 6
OD 01 Pulse value litres/pulse 1 1 1 1 1 10Pulse frequency at Q4 Hz 13.9 15.3 16.7 33.3 44.4 11.1 OD 03 Pulse value litres/pulse 10 10 10 10 10 100Pulse frequency at Q4 Hz 1.4 1.5 1.7 3.3 4.4 1.1
-
9Frequency transmitters
FM-1D/K Frequency transmitter Pulse/current transformer and flowrate indicator for water meters The FM-1D/K is a microprocessor-controlled frequency transmitter with digital
display. It converts pulses into a flow-proportional current to indicate flowrate with thefollowing outputs:
- Current output- Counting pulses- Illuminated digital display
FM-2D/K Frequency transmitter Flowrate summation of two water meters The FM-2D/K is a microprocessor-controlled frequency transmitter with two pulse
outputs It can be used for combining signals from two pulses with a flow direction signal M-Bus output and impulse outputs
Frequency transmitter FM-1D/K FM-2D/KArt. No. 93236 92390InputUniversal input for pulser reed contact or 1 2NAMUR to EN 50227Input frequency range for 0/4...20 mA 0...0.1 to 0...1000Hz 0...300 Hz, 0...150 Hz with
flow direction recognitionMaximum cable length. approx. 6 km approx. 6 kmOutputsCurrent output 0...20 mA or 4...20 mA, 1 2max. load 1 kOhmRelay, NO contact, max. 48 VAC/DC 1 A, 1 2potential-freeOptocoupler output, max. 30 V, 30 mA - 2M-Bus Output - 1Ambient temperature 0...70 C 0...70 CProtection type IP 40 IP 40Supply voltage 230 VAC or 24 VAC / VDC 230 VAC or 24 VAC / VDCMontage 35 mm standard rail 35 mm standard railDimensions 100 x 73 x 114 (B x H x D) mm 100 x 73 x 114 (B x H x D) mm
-
10
+ Sensor - U+
L N PE 24 VAC/D C 12345678+ -
FM-1D/K
select
1234567 8
RUBIN with OD 01
24 V
Pulse counter
Flowrate indicatorPower supply 230 V AC
Alternative24 V DC
or24 V AC
Grounding
+ -
Power supply 24 VAC/DC
Grounding
Forwards flow
Reverse flow
Flowrate indicator
Power supply 230 V/AC or 115 V/AC
RUBIN with OD 01ElektronischerSaldierzhlerRUBIN with OD 01
Dire
ctio
n
Puls
e
Eart
h
FM-1D/K
FM-2D/K
RUBIN meitwin with OD 01Submeter with reed contact
Power supply230 V/AC or 115 V/AC
Power supply24 VAC/DC
Grounding
Forwards flow
Pulse counter
-
11
Installation notes
Nominal sizes: pipes, meters and pipe reducersThe choice of the nominal meter size should not automatically be based on the nominal size of the pipe. The decisive factor is the hig-hest flowrate that occurs continuously in the pipe - this determines the nominal flowrate Q3 of the meter.
Inlet lengthFor MeiStream Plus 3x DN.
Mounting heightRUBIN MeiStream / MeiStream Plus meters have exchangeable velocity measuring units which can be tested and calibrated independ-ently of the housing. For this purpose, the old units are removed upwards. When designing the installation, it is important to ensure thatthere is adequate space above the meter for removal.The for horizontal installation only RUBIN MeiStream Plus is explicitly for horizontal installation only.
Installation positionMeters must not be installed upside-down as then the metrological approval requirements will not be met.
Electrical installationElectrical cables and installation must be carried out by a specialist in accordance with legal requirements.
Measurement error limits
According to Directive OIML R 49
AM066243a
< 8 < 8
-5
-4
-3
-2
-1
0
1
2
3
4
5
Q1 Q2 Q3 Q4
Typical error curve
Error tolerances
%
-
A0.0
5 - 0
3.20
13n
deru
ngen
vor
beha
lten
/ Sou
s r
serv
e de
mod
ifica
tions
Mod
ifica
tion
right
s re
serv
ed /
Copy
right
A
quam
etro
AG
DN
40
DN
80
DN
100
DN
125
DN
150
DN
50
DN
65
Flow in m3/h
Pre
ssu
re lo
ss
Flow in m3/h
DN
40
DN
80
DN
100
DN
150
DN
50
DN
65
Pre
ssu
re lo
ss
SALES PARTNER: HEAD OFFICE:
AQUAMETRO AG Ringstrasse 75CH-4106 TherwilPhone +41 61 725 11 22Fax +41 61 725 15 [email protected] www.aquametro.com
AQUAMETRO (CHINA) PTE LTD AQUAMETRO Japan AQUAMETRO KOREA LTD AQUAMETRO (S.E.A.) PTE LTD AQUAMETRO ME JLT190 Woodlands Industrial Park E5, 1-18-4, Nakane #501, Centum IS Tower, 190 Woodlands Industrial Park E5, Jumeirah Lake Towers#07-15 Woodlands BizHub Meguro-ku 1209 Jaesong-Dong, #07-15 Woodlands BizHub Jumeirah Bay X3, Office 1807
Haeundae-Gu P.O. Box 334132 Singapore 757516 / Singapore Tokyo 152-0031 / Japan Busan 612-050 / Korea Singapore 757516 / Singapore Dubai / UAEPhone +65 6899 1980 Phone +81 3 3723 8611 Phone +82 51 905 55 66 Phone +65 6899 1980 Phone +971 56 7587 801 Fax +65 6899 2972 Fax +81 3 5729 4607 Fax +82 51 905 55 69 Fax +65 6899 [email protected] [email protected] [email protected] [email protected] [email protected]
Pressure loss curves
RUBIN MeiStream
RUBIN MeiStream Plus