VD 1-300 e 03.2013 RUBIN MeiStream, MeiStream Plus Cold water Applications RUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement. Features • Wide measuring range • Measuring units can be replaced • Universal installation (MeiStream) • High overload capacity • Can be retrofitted with non-reactive modules for remote readings • With MID approval Your benefits • Your benefits • Measuring both small and large volumes with one flowmeter • MeiStream Plus is ideal for monitoring piping systems and detecting pipe leaks • No straight inlet necessary for MeiStream

Upload: valeriu-constantinuc

Post on 10-Nov-2015

220 views

Category:

Documents


1 download

DESCRIPTION

S

TRANSCRIPT

  • VD 1

    -300

    e 0

    3.20

    13

    RUBIN MeiStream, MeiStream Plus Cold water

    ApplicationsRUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are

    designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply

    management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement.

    Features Wide measuring range

    Measuring units can be replaced

    Universal installation (MeiStream)

    High overload capacity

    Can be retrofitted with non-reactive modules for

    remote readings

    With MID approval

    Your benefits Your benefits

    Measuring both small and large volumes with one

    flowmeter

    MeiStream Plus is ideal for monitoring piping systems

    and detecting pipe leaks

    No straight inlet necessary for MeiStream

  • gL

    hH

    Range

    Turbine meters with dry-type registers, IP 68 SVGW certification Type examination certificate according to Directive 2004/22 EC Powder-coated grey cast iron housing with flange connections acc. to EN 1092-1 Maximum temperature 50 C Nominal pressure PN 16 Replaceable measuring unit For updating with non-reactive HRI modules or optoelectronic pulsers

    MeiStream: The meter can be installed in horizontal, vertical or inclined positions. The meter head must, however, face upwards or to the side. It requires no inlet path

    The MeiStream Plus is for horizontal installation only and requires an inlet path of 3 x DN

    RUBIN MeiStream

    1) Flanges with 4 holes

    2

    Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80inch 1 1/2 2 2 2 1/2 2 1/2 3 3

    Art. No. 94524 94525 94585 94526 94586 94527 94587Overload Q4 m3/h 60 90 90 120 120 200 200Nominal flowrate Q3 m3/h 40 50 50 70 70 120 120Transitional flowrate horizonal Q2 m3/h 0.32 0.4 0.4 0.63 0.63 0.51 0.51Transitional flowrate vertical Q2 m3/h 0.4 0.51 0.51 0.81 0.81 0.8 0.8Minimum flowrate horizontal Q1 m3/h 0.2 0.15 0.15 0.2 0.2 0.2 0.2Minimum flowrate vertical Q1 m3/h 0.25 0.28 0.28 0.4 0.4 0.5 0.5Starting flow at approx. m3/h 0.05 0.05 0.05 0.07 0.07 0.1 0.1Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5Recording capacity mio. m3 1 1 1 1 1 1 1Data for MID-homologationNominal flowrate Q3 m3/h 25 40 40 63 63 100 100Measuring range horizontal R 125 160 160 160 160 315 315Measuring range vertical R 63 100 100 100 100 125 125Measuring range as shown on delivery R 63 100 100 100 100 100 100Max. pressure loss at Q3 bar 0.08 0.18 0.18 0.37 0.37 0.16 0.16Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3Overall length

    L 220 200 270 200 300 225 300H 120 120 120 120 120 150 150h 69 73 73 85 85 95 95g 200 200 200 200 200 270 270

  • gL

    hH

    3

    Available on request:- Nominal pressure PN 40- Non-ferrous metal version- Version for use in explosion-proof areas- Flanged version e.g. ANSI, JIS

    Nominal diameter DN mm 100 100 125 150 150inch 4 4 5 6 6

    Art. No. 94528 94588 94529 94530 94589Overload Q4 m3/h 300 300 350 600 600Nominal flowrate Q3 m3/h 230 230 250 450 450Transitional flowrate horizonal Q2 m3/h 0.81 0.81 1.02 1.6 1.6Transitional flowrate vertical Q2 m3/h 1.28 1.28 1.6 3.2 3.2Minimum flowrate horizontal Q1 m3/h 0.3 0.3 0.5 0.8 0.8Minimum flowrate vertical Q1 m3/h 0.5 0.5 1 1.6 1.6Starting flow at approx. m3/h 0.11 0.11 0.15 0.3 0.3Smallest readable volume litre 0.5 0.5 0.5 5 5Recording capacity mio. m3 1 1 1 10 10Data for MID-homologationNominal flowrate Q3 m3/h 160 160 160 400 400Measuring range horizontal R 315 315 250 400 400Measuring range vertical R 160 160 125 200 200Measuring range as shown on delivery R 100 100 100 100 100Max. pressure loss at Q3 bar 0.34 0.34 0.2 0.32 0.32Weight kg 18.2 20.2 20.7 35.9 44.2Overall length

    L 250 360 250 300 500H 150 150 160 177 177h 105 105 118 135 135g 270 270 280 356 356

  • gL

    hH

    4

    RUBIN MeiStream Plus, improved measurement dynamics model, for horizontal installation only

    1) Flanges with 4 holes

    Available on request:- Version for use in explosion-proof areas

    Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80inch 1 1/2 2 2 2 1/2 2 1/2 3 3

    Art. No. 94534 94535 94590 94536 94591 94537 94592Overload Q4 m3/h 50 55 55 60 60 120 120Nominal flowrate Q3 m3/h 30 35 35 40 40 63 63Transitional flowrate horizonal Q2 m3/h 0.13 0.13 0.13 0.16 0.16 0.25 0.25Minimum flowrate horizontal Q1 m3/h 0.08 0.07 0.07 0.1 0.1 0.13 0.13Starting flow at approx. m3/h 0.03 0.03 0.03 0.04 0.04 0.04 0.04Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5Recording capacity mio. m3 1 1 1 1 1 1 1Data for MID-homologationNominal flowrate Q3 m3/h 25 25 25 40 40 63 63Measuring range horizontal R 315 315 315 400 400 400 400Measuring range as shown on delivery R 315 315 315 315 315 315 315Max. pressure loss at Q3 bar 0.09 0.08 0.08 0.17 0.17 0.07 0.07Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3Overall length

    L 220 200 270 200 300 225 300H 120 120 120 120 120 150 150h 69 73 73 85 85 95 95g 200 200 200 200 200 270 270

    g

    L

    hH

    Nominal diameter DN mm 100 100 150 150inch 4 4 6 6

    Art. No. 94538 94593 94539 94594Overload Q4 m3/h 160 160 400 400Nominal flowrate Q3 m3/h 100 100 250 250Transitional flowrate horizonal Q2 m3/h 0.4 0.4 0.63 0.63Minimum flowrate horizontal Q1 m3/h 0.2 0.2 0.35 0.35Starting flow at approx. m3/h 0.07 0.07 0.12 0.12Smallest readable volume litre 0.5 0.5 5 5Recording capacity mio. m3 1 1 10 10Data for MID-homologationNominal flowrate Q3 m3/h 100 100 250 250Measuring range horizontal R 400 400 630 630Measuring range as shown on delivery R 315 315 315 315Max. pressure loss at Q3 bar 0.16 0.16 0.14 0.14Weight kg 18.2 20.2 35.9 44.2Overall length

    L 250 360 300 500H 150 150 177 177h 105 105 135 135g 270 270 356 356

  • 5Roller counters

    DN 40...125 DN 150

    Pulsers

    The Meistream / Meistream Plus large capacity water meters are designed to be used with non-reactive HR modules and optoelectronicpulsers. Add-ons can also be retrofitted without affecting the metrological data.

    HRI modules 2 programmable pulse outputs and M-Bus data interface to

    IEC870-5/EN1434-3 Non-reactive inductive tap with external manipulation detection Lifetime of battery approx. 12 years, external power supply via M-Bus or

    auxiliary voltage 10...42 VDC approx. 15 years Cable length 3 m Ambient temperature -10 - 60 C, IP 68 Forward/reverse flow recognition Pulse value, length and type selectable with MiniCom software

    M-Bus output, data transmission:- Meter reading- Instantaneous value- Fabrication number- Meter number with secondary address- Monthly meter reading on any day selected- Meter reading with current and previous years billing date selected- Minimum and maximum flowrate with time and date- Reverse flow volume with time and date- Pipe breakage and leak detection with selectable limit value- Detection of any attempt at external manipulation and broken cable

    Pulse outputs:- Programmable as:

    Opto-OD (NAMUR to EN 60947-5-6), pulse width 6 ms orOpen collector, pulse width 32, 128 or 500 ms, max. 48 VDC, max. 0.2 A, max. 4 Watt

    m3

    x 0,001

    x 0,01

    x 0,1

    12

    3456

    7

    89 0

    12

    3456

    7

    89 0

    12

    3456

    7

    89 0

    OP

    TO

    x10m3

    x 0,01

    x 0,1

    x 1

    12

    3456

    7

    89 0

    12

    3456

    7

    89

    0

    12

    3456

    7

    89

    OP

    TO 0

    Nominal diameter Minimum Display Smallest Pulse value Pulse valuescale value range pulse value with OD 01 with OD 03

    with HRI-ModulDN 40...125 0.5 litre 1'000'000 m3 10 litres 1 litre 10 litreDN 150 5 litres 10'000'000 m3 100 litres 10 litres 100 litres

  • The following pulse modes can be set:

    1) Reverse pulses are compensated by suppressing the identical number of forward pulses.2) Can be assigned for pipe breakage, leakage detection, external interference and cable breakage.

    MiniCom software is required for changing set parameters.

    The HRI-Mei pulser is available with the following parameters on request:

    6

    Pulse mode B1 B2 B3 B4 B5 B6Pulse outputI1 (white) Balanced Forward Forwards and Balanced NAMUR pulses NAMUR pulses with

    pulses 1) pulses reverse pulses pulses 1) with forward/ blackflow suppres-reverse sion (OD-AM)recognition

    I2 (yellow) On = Alarm 2) Reverse On = Forwards Off = Alarm 2) Not used Not usedpulses flow

    Type designation Version Art. No.HRI-Mei/10/B4/D100/T500 DN 40...125: Open collector, 100 litres/pulse, pulse length 500 ms 80508HRI-Mei/10/B4/D1000/T500 DN 40...125: Open collector, 1000 litres/pulse, pulse length 500 ms 80616HRI-Mei/100/B4/D1000/T500 DN 150: Open collector, 1000 litres/pulse, pulse length 500 ms 80509HRI-Mei/10/B5/D10/T6 DN 40...125: NAMUR /EN 60947-5-6), 10 litres/pulse, pulse length 6 ms 80510HRI-Mei/100/B5/D100/T6 DN 150: NAMUR /EN 60947-5-6), 100 litres/pulse, pulse length 6 ms 80511HRI-Mei-CDL/10/D10/T6 DN 40...125: Forward/reverse pulse with plug for CDL data logger, 80512

    10 litres/pulse, pulse length 6 msHRI-Mei-CDL/100/D100/T6 DN 150: Forward/reverse pulse with plug for CDL data logger, 80513

    100 litres/pulse, pulse length 6 ms

    Version DN 40...125 DN 150Open collector / NAMUR 0.01, 0.025, 0.05, 0.1 or 0.1, 0.25, 0.5, 1 or

    0.25, 0.5, 1 m3/pulse 2.5, 5, 10 m3/pulsepulse mode B1 - B6 pulse mode B1 - B6pulse length 32, 128 or 500 ms pulse length 32, 128 or 500 mspulse length NAMUR 6 ms pulse length NAMUR 6 ms

  • 7Configuration notes:The HRI-Mei impulse outputs are open collector outputs with no internal power limit which are galvanically connected to the M-Bus.

    Typical application for connection to a PLS (programmable logic controller) with a power supply connected:

    1) This connection is optional and taken over by the power supply for the HRI module. The service life of the internal battery increases to greater than 15 years.

    Typical application for connection to a PLC (programmable logic controller) connected to earth:

    1) This connection is optional and taken over by the power supply for the HRI module. The service life of the internal battery increases to greater than 15 years.

    green

    brown

    white

    yellow

    grey

    M -Bus

    M -Bus

    Impulse I1

    Impulse I2

    Ground

    HRI-Mei

    Ground

    + 24 V

    Impulse input

    1)

    PLC

    Ground

    1 kOhm

    green

    brown

    white

    yellow

    grey

    M -Bus

    M -Bus

    Impulse I1

    Impulse I 2

    Ground

    HRI-Mei

    Ground

    + 24 V

    Impulse input

    1)

    PLC

  • 8Optoelectronic pulsers

    IR reflex light barriers to EN 50227 as a plug-in version Non-reactive optical tap Cable length 3 m Ambient temperature -10 - 70 C, IP 68

    Technical data:- Power supply 8.2 VDC- Switch current (actuated) 1.2 mA- Quiescent current (non-contact) 2.1 mA- Forwards and reverse flow detection is built in by means of an additional current threshold at 1.5 mA. With forward flow, the rising

    pulse edge thus has an additional current threshold of 1.5 mA. With reverse flow, the current threshold lies on the falling edge of the pulse.Forward flow: Reverse flow:

    - Pulse length is dependent on the flowrate and at meter standstill a continuous pulse is possible.

    Standard pulse values and frequencies

    MeiStream

    MeiStream Plus

    Type designation Version Art. No.OD 01 Optoelectronic pulser, smaller pulse value 93750OD 03 Optoelectronic pulser, larger pulse value 93752

    Nominal diameter DN mm 40 50 65 80 100 125 150inch 1 1/2 2 2 1/2 3 4 5 6

    OD 01 Pulse value litres/pulse 1 1 1 1 1 1 10Pulse frequency at Q4 Hz 16.7 25 33.3 55.7 83.3 97.2 16.7OD 03 Pulse value litres/pulse 10 10 10 10 10 10 100Pulse frequency at Q4 Hz 1.7 2.5 3.3 5.7 8.4 9.8 1.7

    Nominal diameter DN mm 40 50 65 80 100 150inch 1 1/2 2 2 1/2 3 4 6

    OD 01 Pulse value litres/pulse 1 1 1 1 1 10Pulse frequency at Q4 Hz 13.9 15.3 16.7 33.3 44.4 11.1 OD 03 Pulse value litres/pulse 10 10 10 10 10 100Pulse frequency at Q4 Hz 1.4 1.5 1.7 3.3 4.4 1.1

  • 9Frequency transmitters

    FM-1D/K Frequency transmitter Pulse/current transformer and flowrate indicator for water meters The FM-1D/K is a microprocessor-controlled frequency transmitter with digital

    display. It converts pulses into a flow-proportional current to indicate flowrate with thefollowing outputs:

    - Current output- Counting pulses- Illuminated digital display

    FM-2D/K Frequency transmitter Flowrate summation of two water meters The FM-2D/K is a microprocessor-controlled frequency transmitter with two pulse

    outputs It can be used for combining signals from two pulses with a flow direction signal M-Bus output and impulse outputs

    Frequency transmitter FM-1D/K FM-2D/KArt. No. 93236 92390InputUniversal input for pulser reed contact or 1 2NAMUR to EN 50227Input frequency range for 0/4...20 mA 0...0.1 to 0...1000Hz 0...300 Hz, 0...150 Hz with

    flow direction recognitionMaximum cable length. approx. 6 km approx. 6 kmOutputsCurrent output 0...20 mA or 4...20 mA, 1 2max. load 1 kOhmRelay, NO contact, max. 48 VAC/DC 1 A, 1 2potential-freeOptocoupler output, max. 30 V, 30 mA - 2M-Bus Output - 1Ambient temperature 0...70 C 0...70 CProtection type IP 40 IP 40Supply voltage 230 VAC or 24 VAC / VDC 230 VAC or 24 VAC / VDCMontage 35 mm standard rail 35 mm standard railDimensions 100 x 73 x 114 (B x H x D) mm 100 x 73 x 114 (B x H x D) mm

  • 10

    + Sensor - U+

    L N PE 24 VAC/D C 12345678+ -

    FM-1D/K

    select

    1234567 8

    RUBIN with OD 01

    24 V

    Pulse counter

    Flowrate indicatorPower supply 230 V AC

    Alternative24 V DC

    or24 V AC

    Grounding

    + -

    Power supply 24 VAC/DC

    Grounding

    Forwards flow

    Reverse flow

    Flowrate indicator

    Power supply 230 V/AC or 115 V/AC

    RUBIN with OD 01ElektronischerSaldierzhlerRUBIN with OD 01

    Dire

    ctio

    n

    Puls

    e

    Eart

    h

    FM-1D/K

    FM-2D/K

    RUBIN meitwin with OD 01Submeter with reed contact

    Power supply230 V/AC or 115 V/AC

    Power supply24 VAC/DC

    Grounding

    Forwards flow

    Pulse counter

  • 11

    Installation notes

    Nominal sizes: pipes, meters and pipe reducersThe choice of the nominal meter size should not automatically be based on the nominal size of the pipe. The decisive factor is the hig-hest flowrate that occurs continuously in the pipe - this determines the nominal flowrate Q3 of the meter.

    Inlet lengthFor MeiStream Plus 3x DN.

    Mounting heightRUBIN MeiStream / MeiStream Plus meters have exchangeable velocity measuring units which can be tested and calibrated independ-ently of the housing. For this purpose, the old units are removed upwards. When designing the installation, it is important to ensure thatthere is adequate space above the meter for removal.The for horizontal installation only RUBIN MeiStream Plus is explicitly for horizontal installation only.

    Installation positionMeters must not be installed upside-down as then the metrological approval requirements will not be met.

    Electrical installationElectrical cables and installation must be carried out by a specialist in accordance with legal requirements.

    Measurement error limits

    According to Directive OIML R 49

    AM066243a

    < 8 < 8

    -5

    -4

    -3

    -2

    -1

    0

    1

    2

    3

    4

    5

    Q1 Q2 Q3 Q4

    Typical error curve

    Error tolerances

    %

  • A0.0

    5 - 0

    3.20

    13n

    deru

    ngen

    vor

    beha

    lten

    / Sou

    s r

    serv

    e de

    mod

    ifica

    tions

    Mod

    ifica

    tion

    right

    s re

    serv

    ed /

    Copy

    right

    A

    quam

    etro

    AG

    DN

    40

    DN

    80

    DN

    100

    DN

    125

    DN

    150

    DN

    50

    DN

    65

    Flow in m3/h

    Pre

    ssu

    re lo

    ss

    Flow in m3/h

    DN

    40

    DN

    80

    DN

    100

    DN

    150

    DN

    50

    DN

    65

    Pre

    ssu

    re lo

    ss

    SALES PARTNER: HEAD OFFICE:

    AQUAMETRO AG Ringstrasse 75CH-4106 TherwilPhone +41 61 725 11 22Fax +41 61 725 15 [email protected] www.aquametro.com

    AQUAMETRO (CHINA) PTE LTD AQUAMETRO Japan AQUAMETRO KOREA LTD AQUAMETRO (S.E.A.) PTE LTD AQUAMETRO ME JLT190 Woodlands Industrial Park E5, 1-18-4, Nakane #501, Centum IS Tower, 190 Woodlands Industrial Park E5, Jumeirah Lake Towers#07-15 Woodlands BizHub Meguro-ku 1209 Jaesong-Dong, #07-15 Woodlands BizHub Jumeirah Bay X3, Office 1807

    Haeundae-Gu P.O. Box 334132 Singapore 757516 / Singapore Tokyo 152-0031 / Japan Busan 612-050 / Korea Singapore 757516 / Singapore Dubai / UAEPhone +65 6899 1980 Phone +81 3 3723 8611 Phone +82 51 905 55 66 Phone +65 6899 1980 Phone +971 56 7587 801 Fax +65 6899 2972 Fax +81 3 5729 4607 Fax +82 51 905 55 69 Fax +65 6899 [email protected] [email protected] [email protected] [email protected] [email protected]

    Pressure loss curves

    RUBIN MeiStream

    RUBIN MeiStream Plus