1218617471 standard flush plans for mechanical seal

11
Standard flush plans for mechanical seal PLAN 01 See Figure 1. Integral (internal) recirculation is from pump discharge to seal. Recommended for clean pumpage only. Care shall be taken to ensure that integral recirculation is sufficient to maintain stable face conditions. a) Piping and instrumentation schematic b) Seal chamber details 1- inlet 2- quench/drain (Q/D) 3- seal chamber Figure 1-PLAN 01 PLAN 02 See Figure 2. Dead-ended seal chamber with no recirculation of flushed fluid. Self-venting arrangements preferred on horizontal pumps a) Piping and instrumentation schematic b) Seal chamber details 1 plugged connections for possible future circulating fluid 2 vent (V), if required 3 heating/cooling inlet (HI or CI), heating/cooling outlet (HO or CO) 4 quench/drain (Q/D) 5 seal chamber Figure 2-PLAN 02 PLAN 11 See Figure 3.Recirculation from pump discharge through a flow control orifice to the seal. The flow enters the seal chamber adjacent to the mechanical seal faces, flushes the faces, and flows across the seal back into the pump. a) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber Figure 3-PLAN 11 www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Upload: alexsung1975

Post on 22-May-2015

3.382 views

Category:

Technology


3 download

TRANSCRIPT

Page 1: 1218617471 standard flush plans for mechanical seal

Standard flush plans for mechanical sealPLAN 01 See Figure 1. Integral (internal) recirculation is from pump discharge to seal. Recommended for clean pumpage only. Care shall be taken to ensure that integral recirculation is sufficient to maintain stable face conditions.

a) Piping and instrumentation schematic b) Seal chamber details

1- inlet 2- quench/drain (Q/D) 3- seal chamber Figure 1-PLAN 01

PLAN 02 See Figure 2. Dead-ended seal chamber with no recirculation of flushed fluid. Self-venting arrangements preferred on horizontal pumps

a ) Piping and instrumentation schematic b) Seal chamber details 1 plugged connections for possible future circulating fluid 2 vent (V), if required

3 heating/cooling inlet (HI or CI), heating/cooling outlet (HO or CO) 4 quench/drain (Q/D) 5 seal chamber Figure 2-PLAN 02 PLAN 11 See Figure 3.Recirculation from pump discharge through a flow control orifice to the seal. The flow enters the seal chamber adjacent to the mechanical seal faces, flushes the faces, and flows across the seal back into the pump.

a) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber

Figure 3-PLAN 11

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 2: 1218617471 standard flush plans for mechanical seal

PLAN 12 See Figure 4. Recirculation from pump discharge through a strainer and flow control orifice to the seal. This plan is similar to Plan 11 but with the addition of a strainer to remove occasional particles. Strainers are not normally recommended because blockage of the strainer will cause seal failure.

a) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber

Figure 4-PLAN 12 PLAN 13 See Figure 5. Recirculation from pump seal chamber through a flow control orifice and back to the pump suction.

a) Piping and instrumentation schematic b) Seal chamber details 1 to pump suction 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber

Figure 5-PLAN 13 PLAN 14 See Figure 6. Recirculation from pump discharge through a flow control orifice to the seal and simultaneously from the seal chamber through a control orifice (if required) to pump suction. This allows fluid to enter the seal chamber and provide cooling while continually venting and reducing the pressure in the seal chamber. Plan 14 is a combination of Plan 11 and Plan 13.

a ) Piping and instrumentation schematic b) Seal chamber details 1 to pump suction 2 from pump discharge 3 flush inlet (FI) 4 flush outlet (FO) 5 quench/drain (Q/D) 6 seal chamber

Figure 6-PLAN 14

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 3: 1218617471 standard flush plans for mechanical seal

PLAN 21 See Figure 7.Recirculation from pump discharge through a flow control orifice and cooler, then into the seal chamber.

a ) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber TI temperature indicator

Figure 7-PLAN 21 PLAN 22 See Figure 8. Recirculation from the pump discharge through a strainer, a flow control orifice, and a cooler and into the seal chamber. Strainers are not normally recommended because blockage of the strainer will cause seal failure.

a) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber TI temperature indicator

Figure 8-PLAN 22 PLAN 23 See Figure 9. Recirculation from a pumping ring in the seal chamber through a cooler and back into the seal chamber. This plan can be used on hot applications to minimize the heat load on the cooler by cooling only the small amount of liquid that is recirculated.

a) Piping and instrumentation schematic b) Seal chamber details 1 flush outlet (FO) 2 flush inlet (FI) 3 quench/drain (Q/D) 4 seal chamber 5 vent TI temperature indicator

Figure 9-PLAN 23

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 4: 1218617471 standard flush plans for mechanical seal

PLAN 31 See Figure 10. Recirculation from pump discharge through a cyclone separator delivering the clean fluid to the seal chamber. The solids are delivered to the pump suction line.

a) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 to pump suction 3 flush (F) 4 quench/drain (Q/D) 5 seal chamber

Figure 10-PLAN 31 PLAN 32 See Figure 11. Flush is injected into the seal chamber from an external source. Care must be exercised in choosing a proper source of seal flush to eliminate potential for vaporization of the injected fluid and to avoid contamination of the fluid being pumped with the injected flush.

a) Piping and instrumentation schematic b) Seal chamber details 1 from external source 2 flush (F) 3 quench/drain (Q/D) 4 seal chamber FI flow indicator

PI pressure indicator TI temperature indicator Figure 11-PLAN 32

PLAN 41 See Figure 12. Recirculation from pump discharge through a cyclone separator delivering the clean fluid to a seal cooler and then to the seal chamber. The solids are delivered to the pump suction line.

a ) Piping and instrumentation schematic b) Seal chamber details 1 from pump discharge 2 to pump suction 3 flush (F) 4 quench/drain (Q/D) 5 seal chamber TI temperature indicator

Figure 12-PLAN 41 www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 5: 1218617471 standard flush plans for mechanical seal

PLAN 51 See Figure 13. External reservoir providing a dead-ended blanket for fluid to the quench connection of the gland.

a) Piping and instrumentation schematic b) Seal chamber details

1 reservoir 2 quench (Q) 3 drain (D), plugged 4 flush (F) 5 seal chamber

Figure 13-PLAN 51 PLAN 52 See Figure 14. External reservoir providing buffer liquid for the outer seal of an Arrangement 2 seal. During normal operation, circulation is maintained by an internal pumping ring. The reservoir is usually continuously vented to a vapour recovery system and is maintained at a pressure less than the pressure in the seal chamber.

a) Piping and instrumentation schematic b) Seal chamber details 1 to collection system 2 reservoir 3 make-up buffer fluid 4 flush (F) 5 liquid buffer outlet (LBO) 6 liquid buffer inlet (LBI) 7 seal chamber LSH level switch high LSL level switch low LI level indicator PI pressure indicator PSH pressure switch high a Items above this line are the responsibility of the purchaser; items below this line shall be supplied by the vendor. b Normally open. c If specified.

Figure 14-PLAN 52

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 6: 1218617471 standard flush plans for mechanical seal

PLAN 53A See Figure 15. Pressurized external barrier fluid reservoir supplying clean fluid to the seal chamber. Circulation is by an internal pumping ring. Reservoir pressure is greater than the process pressure being sealed.

a) Piping and instrumentation schematic b) Seal chamber details 1 from external pressure source 2 reservoir 3 make-up barrier fluid 4 flush (F) 5 liquid barrier outlet (LBO) 6 liquid barrier inlet (LBI) 7 seal chamber LSH level switch high LSL level switch low LI level indicator PI pressure indicator PSL pressure switch low a Items above this line are the responsibility of the purchaser; items below this line shall be supplied by the vendor. b Normally open. c If specified.

Figure 15-PLAN 53A PLAN 53B See Figure 16. External piping provides fluid for the outer seal of a pressurized dual seal arrangement. Pre-pressurized bladder accumulator provides pressure to the circulation system. Flow is maintained by an internal pumping ring. Heat is removed from the circulation system by an air-cooled or water-cooled heat exchanger.

a) Piping and instrumentation schematic b) Seal chamber details 1 make-up barrier fluid 2 bladder accumulator 3 bladder charge connection 4 flush (F) 5 liquid barrier outlet (LBO) 6 liquid barrier inlet (LBI) 7 seal chamber 8 vent PI pressure indicator PSL pressure switch low TI temperature indicator

Figure 16-PLAN 53B

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 7: 1218617471 standard flush plans for mechanical seal

PLAN 53C See Figure 17. External piping provides fluid for the outer seal of a pressurized dual seal arrangement. Reference line from the seal chamber to a piston accumulator provides pressure to the circulation system. Flow is maintained by an internal pumping ring. Heat is removed from the circulation system by an air-cooled or water-cooled heat exchanger.

a) Piping and instrumentation schematic b) Seal chamber details 1 make-up barrier fluid 2 piston accumulator 3 flush (F) 4 liquid barrier outlet (LBO) 5 liquid barrier inlet (LBI) 6 seal chamber 7 vent LI level indicator LSL level switch low PI pressure indicator PRV pressure relief valve PSL pressure switch low TI temperature indicator

Figure 17-PLAN 53C PLAN 54 See Figure 18. Pressurized external barrier fluid reservoir or system supplying clean fluid to the seal chamber. Circulation is by an external pump or pressure system. Reservoir pressure is greater than the process pressure being sealed.

a) Piping and instrumentation schematic b) Seal chamber details 1 from external source 2 to external source 3 flush (F) 4 liquid barrier outlet (LBO) 5 liquid barrier inlet (LBI) 6 seal chamber

Figure 18-PLAN 54

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 8: 1218617471 standard flush plans for mechanical seal

PLAN 61 See Figure 19. Tapped and plugged connections for the purchaser’s use. Typically this plan is used when the purchaser is to provide fluid (such as steam, gas, or water) to an external sealing device.

a) Piping and instrumentation schematic b) Seal chamber details 1 quench (Q), plugged 2 drain (D), plugged 3 flush (F) 4 seal chamber

Figure 19-PLAN 61 PLAN 62 See Figure 20.Exterior source providing a quench. The quench may be required to prevent solids from accumulating on the atmospheric side of the seal. Typically used with a close-clearance throttle bushing.

a) Piping and instrumentation schematic b) Seal chamber details 1 quench (Q) 2 drain (D) 3 flush (F) 4 seal chamber

Figure 20-PLAN 62 PLAN 65 See Figure 21. External drain piping is arranged to alarm on high seal leakage, measured by a float type level switch. The orifice downstream of the level switch is typically 5 mm (0,25 in) and is located in a vertical piping leg.

a) Piping and instrumentation schematic b) Seal chamber details 1 to liquid collection system 2 flush (F) 3 quench (Q), plugged 4 drain (D) 5 seal chamber LSH level switch high

Figure 21-PLAN 65

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 9: 1218617471 standard flush plans for mechanical seal

PLAN 71 See Figure 22. Tapped connections for purchaser’s use. Typically, this plan is used when the purchaser may use buffer gas in the future.

a) Piping and instrumentation schematic b) Seal chamber details 1 flush 2 containment seal vent (CSV), plugged 3 containment seal drain (CSD), plugged

4 gas buffer inlet (GBI), plugged 5 seal chamber Figure 22-PLAN 71

PLAN 72 See Figure 23. Externally supplied gas buffer for Arrangement 2 seals. Buffer gas may be used alone to dilute seal leakage or in conjunction with Plan 75 or 76 to help sweep leakage into a closed collection system. Pressure of buffer gas is lower than the process-side pressure of inner seal.

a) Piping and instrumentation schematic b) Seal chamber details

1 buffer gas panel 2 flush (F) 3 containment seal vent (CSV) 4 containment seal drain (CSD) 5 gas buffer inlet (GBI) 6 seal chamber FE flow meter (magnetic type shown) FIL coalescing filter, used to ensure solids and/or liquids which might be present in buffer gas do not contaminate seals PCV pressure control valve, used to limit buffer gas pressure to prevent reverse pressurization of inner seal and/or limit

pressure applied to containment seal PI pressure indicator PSL pressure switch low FSH flow switch high a If specified. b Items to the left of this line shall be supplied by the vendor; items to the right are the responsibility of the purchaser.

Figure 23-PLAN 72

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 10: 1218617471 standard flush plans for mechanical seal

PLAN 74 See Figure 24. Externally supplied barrier gas used to positively prevent process fluid from leaking to atmosphere. Pressure of barrier gas is higher than process side of inner seal. Venting of the seal chamber may be required prior to start-up and operation to avoid the collection of gas in the pump.

a) Piping and instrumentation schematic b) Seal chamber details 1 gas barrier panel 2 vent (if required) 3 gas barrier outlet (normally closed), used only to depressurize seal chamber 4 gas barrier inlet 5 seal chamber FE flow meter FIL coalescing filter, used to ensure solids and/or liquids which might be present in barrier gas do not contaminate seals FSH flow switch high PI pressure indicator PCV pressure control valve, set pressure above process side of inner seal PSL pressure switch low a Items to the left of this line shall be supplied by the vendor; items to the right are the responsibility of the purchaser. b If specified.

Figure 24-PLAN 74 PLAN 75 See Figure 25. Containment seal chamber drain for condensing leakage on Arrangement 2 seals. This plan is used when pumped fluid condenses at ambient temperatures. System is supplied by vendor.

a ) Piping and instrumentation schematic b) Seal chamber details 1 to vapour collection system 2 to liquid collection system 3 test connection 4 flush (F) 5 containment seal vent (CSV), plugged 6 containment seal drain (CSD) 7 gas buffer inlet (GBI) 8 seal chamber L I level indicator LSH level switch high PSH pressure switch high PI pressure indicator b Items above this line are the responsibility of the purchaser; items below this line shall be supplied by the vendor.

Figure 25-PLAN 75

www.mechanical-pump-shaft-seals.com www.easterny.com [email protected]

Page 11: 1218617471 standard flush plans for mechanical seal

PLAN 76 See Figure 26. Containment seal chamber drain for non-condensing leakage on Arrangement 2 seals. This plan is used when pumped fluid does not condense at ambient temperatures. System is supplied by the vendor. Tubing shall be 13 mm (1/2 in) minimum diameter and shall rise continuously from the CSV connection to the piping /instrumentation harness. The harness shall be pipe of minimum size DN 15 (NPS 1/2). Harness shall be supported from overhead structure or side stand such that no strain is put on tubing connected to seal gland.

a ) Piping and instrumentation schematic b) Seal chamber details 1 to vapour recovery system 2 tube, see below 3 pipe, see below 4 flush (F) 5 containment seal vent (CSV) 6 containment seal drain (CSD) 7 gas buffer inlet (GBI) 8 seal chamber PI pressure indicator PSH pressure switch high

a Items above this line are the responsibility of the purchaser; items below this line shall be supplied by the vendor. Figure 26-PLAN 76