1210153_634531613786611250

16
PRACTICAL TRAINING SEMINAR SHUBHAM JAIN 132 KV G.S.S.CHAMBAL JAIPUR

Upload: shubham-jain

Post on 06-Dec-2015

1 views

Category:

Documents


0 download

DESCRIPTION

132 kv g.s.s chambal jaipur 1. Practical training seminar SHUBHAM JAIN132 KV G.S.S.CHAMBAL JAIPUR 2. CONTENTS:GENERAL DISCUSSION ON SUB STATIONS 3. FEEDERS ARE USED 4. COMPONENTS USED 5. BUSBARS 6. CIRCIUT BREAKERS 7. POWER TRANSFORMERS 8. CURRENT TRANSFORMERS 9. RELAYGENERALDISCUSSION: Substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Types:Transmission substation connects two or more transmission lines. Distribution substation transfers power from transmission system to the distribution system of an area. 10. Feeders are used There are 28 feeders are connected in this 9(33kv) and 19(11kv)33 kvFeeders are:khasakothidurgapuramnitlalkhotispairvidhansabha22 godambisalpursewage form 11. CONTINUED…..11kv Feeders are:ramnivasbagh -1nirmannagarmaheshnagare.s.iresidencyramnivasbagh-2queen`s road ajmerroadkhasakhoti22 godamlalkhotisewage formpartaplineg.n1g.n2jamunanagarnew sanganer 12. COMPONENTS USED Busbar system 13. Circiut breakers 14. Transformers 15. Relays Busbar system:- A bus bar is a conducting bar that carries heavy currents to supply several electric circuits. When a no. of generators or feeders operating at the same voltage level to be directly connected electrically, busbar are used as the common electrical component. Bus bars are copper rod or thin walled tubes and operate at constant voltage.There are two typs of busbars:- Main busbar 16. Auxiliary busbar CIRCUIT BREAKER: A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit.PRINCIPLE: A ckt breaker essentially consists of fixed & moving contacts, called electrodes under normal operating conditions, these contacts remain closed & will not open automatically until & unless the systems becomes faulty. When a fault occurs on any part of the system, the trip coils of the breaker get energised & the moving contacts are pulled apart by some mechanism. Thus opening the circuit. 17. CONTINUED….CLASSIFICATION:oil circuit breakers 18. SulphurHexa Fluoride circuit breakers 19. Air-Blast circuit breakers 20. vacuum circuit breakers 21. Under training SF6 type, vacuum ckt breaker & Air-Blast ckt breakers were used in the GSS. CONTINUED….Oil filled ckt. breakerSf6 ckt. breaker 22. Transformers: Transformer is an electrical machine which works on the principle of electromagnetic induction. It transfers electric power from one electric ckt to other with the help magnetic path(flux) on constant frequency but equal or different current voltages. The winding which is connected to the supply is called primary winding & that winding is connected to the load is called secondary winding. In CHAMBAL G.S.S there are six transformers used. 23. SPECIFICATION: 24. CURRENT TRANSFORMERS: C.T. is an instrument transformer used for protection & metering of high values of currents. C.T. is used for reducing a.c from higher to lower value for measurement/protection/control. There are two classes of C.T: protective C.T measuring C.T current transformer 25. POTENTIAL TRANSFORMERS:Potential transformers are instrument transformers. They have a large number of secondary turns and a fewer number of primary turns. They are used to increase the range of voltmeters in electrical substations and generating stations. Potential transfo

TRANSCRIPT

Page 1: 1210153_634531613786611250

PRACTICAL TRAINING SEMINAR

SHUBHAM JAIN132 KV G.S.S.CHAMBAL JAIPUR

Page 2: 1210153_634531613786611250

CONTENTS:

•GENERAL DISCUSSION ON SUB STATIONS

•FEEDERS ARE USED

•COMPONENTS USED

•BUSBARS

•CIRCIUT BREAKERS

•POWER TRANSFORMERS

•CURRENT TRANSFORMERS

•RELAY

Page 3: 1210153_634531613786611250

GENERAL DISCUSSION:

Substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions.

Types: Transmission substation connects two or more

transmission lines.

Distribution substation transfers power from transmission system to the distribution system of an area.

Page 4: 1210153_634531613786611250

FEEDERS ARE USED

There are 28 feeders are connected in this 9(33kv)

and 19(11kv)

33 kv Feeders are:

khasa kothi

durga pura

mnit

lal khoti

spair

vidhan sabha

22 godam

bisal pur

sewage form

Page 5: 1210153_634531613786611250

CONTINUED…..

11kv Feeders are: ramnivas bagh -1

nirman nagar

mahesh nagar

e.s.i

residency

ramnivas bagh-2

queen`s road

ajmer road

khasa khoti

22 godam

lal khoti

sewage form

partap line

g.n 1

g.n 2

jamuna nagar

new sanganer

Page 6: 1210153_634531613786611250

• Busbar system

• Circiut breakers

• Transformers

• Relays

COMPONENTS USED

Page 7: 1210153_634531613786611250

BUSBAR SYSTEM:- A bus bar is a conducting bar that carries heavy currents to supply several electric circuits.

When a no. of generators or feeders operating at the same voltage level to be directly connected electrically, busbar are used as the common electrical component. Bus bars are copper rod or thin walled tubes and operate at constant voltage.

There are two typs of busbars:-

o Main busbar

oAuxiliary busbar

Page 8: 1210153_634531613786611250

CIRCUIT BREAKER: A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit.

PRINCIPLE: A ckt breaker essentially consists of fixed & moving contacts, called electrodes under normal operating conditions, these contacts remain closed & will not open automatically until & unless the systems becomes faulty. When a fault occurs on any part of the system, the trip coils of the breaker get energised & the moving contacts are pulled apart by some mechanism. Thus opening the circuit.

Page 9: 1210153_634531613786611250

CONTINUED….

CLASSIFICATION:

•oil circuit breakers

• Sulphur Hexa Fluoride circuit breakers

• Air-Blast circuit breakers

• vacuum circuit breakers

•Under training SF6 type, vacuum ckt breaker & Air-Blast ckt breakers were used in the GSS.

Page 10: 1210153_634531613786611250

CONTINUED….

Oil filled ckt. breaker Sf6 ckt. breaker

Page 11: 1210153_634531613786611250

TRANSFORMERS:

Transformer is an electrical machine which works on the principle of electromagnetic induction. It transfers electric power from one electric ckt to other with the help magnetic path(flux) on constant frequency but equal or different current voltages.

The winding which is connected to the supply is called primary winding & that winding is connected to the load is called secondary winding.

In CHAMBAL G.S.S there are six transformers used.

Page 12: 1210153_634531613786611250

SPECIFICATION: S.NO.

SERIAL NO. RATTING CAPACITY YEAR OF

MANUFACTURE

1 RY/2590/2 132/11 KV 16/20 MVA 2010

2 T&R 220066 132/11KV 60/20 MVA 2009

3 B-2937.2 132/11 KV 16/20 MVA 1997

4 T-8543/1 132/11KV 16/20 MVA 1997

5 01572/1448 132/33 KV 40/50 MVA 2001

6 28.001.6827 132/33 KV 40/50 MVA 2006

Page 13: 1210153_634531613786611250

CURRENT TRANSFORMERS:

C.T. is an instrument transformer used for protection & metering of high values of currents. C.T. is used for reducing a.c from higher to lower value for measurement/protection/control. There are two classes of C.T:

protective C.T

measuring C.T

current transformer

Page 14: 1210153_634531613786611250

POTENTIAL TRANSFORMERS:Potential transformers are instrument transformers. They have a large number of secondary turns and a fewer number of primary turns. They are used to increase the range of voltmeters in electrical substations and generating stations.

Potential transformer

Page 15: 1210153_634531613786611250

RELAYS:

A relay is an electrically operated switch. Many relays use an electromagnet to operate a switching mechanism mechanically, but other operating principles are also used. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits, repeating the signal coming in from one circuit and re-transmitting it to another. Relays were used extensively in telephone exchanges and early computers to perform logical operations.

Page 16: 1210153_634531613786611250

THANK YOU…!!!

&

ANY QUERIES…???