UniConn SCADAJ Anderson
![Page 2: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/2.jpg)
2 Initials04/08/23
Key Points on UniConn SCADA Functionality
UniConn communicates via the Modbus RTU protocol over RS-232 or RS-485
The UniConn has several independent COM ports The UniConn requires an Isolated Com. Card for any
connection to a SCADA system or SCB The UniConn does not require a Modbus Multiplexer The UniConn has been proven to work with dozens of 3rd
party SCADA systems, DCS systems, and RTUs
![Page 3: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/3.jpg)
3 Initials04/08/23
Enabling SCADA Communication
In order to enable remote communications, an Isolated Communication Card is Required.
![Page 4: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/4.jpg)
4 Initials04/08/23
Multi-Master Connections
Each com card enabled port can have different communication settings, including baud rate and Modbus Slave ID.
![Page 5: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/5.jpg)
5 Initials04/08/23
Sample RS-232 Connection
![Page 6: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/6.jpg)
6 Initials04/08/23
Sample RS-485 Connection
![Page 7: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/7.jpg)
7 Initials04/08/23
Configuring the Port
From the default UniConn screen, press any button Press MENU Press SETUP Press NEXT until you see the “PORT x” you are interested in. Press EDIT
You will now have access to all of the communication parameters for that particular port.
![Page 8: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/8.jpg)
8 Initials04/08/23
Contacting InTouch for Technical Assistance
When contacting InTouch for SCADA/SCB-related UniConn technical assistance, you MUST provide the following: Client Name, Field Name, Site Name Wellview *.STE File UniConn Firmware Version Wellview Version Device you are connecting the UniConn to SCADA network parameters (baud rate, data & stop bits, etc.)
![Page 9: 11_UniConn SCADA](https://reader033.vdocuments.us/reader033/viewer/2022061110/5452950faf79590c308b4f7d/html5/thumbnails/9.jpg)
9 Initials04/08/23
Reference Material
Review UniConn SCADA Guide, InTouch Content: 4201401