11644 iss c vantage 2 instructions

2
( Please leave this instruction leaflet with the end user) INSTRUCTION LEAFLET 1 - Fitting the Vantage cistern - 5 - Maintenance of the outlet valve - 5.6 - Wash seal in clean water. 1.1 - Prior to installation ensure there is sufficient room for the Vantage and any support frame, push button etc. to be fitted without interference. 155 min 460 369 From top of flushpipe 101 328 max 740 max 440 min 320 - 360 BS EN 37 Optimum button position 1.3 - Fitting the mounting brackets 1.3.1 Position the template and mark holes, ensuring it is level 1.3.2 Drill holes to suit No 8 csk screw (not supplied) 1.3.3 Fit the mounting bracket and clips 1.2. Changing the capacity of the cistern (if required) 1.2.2 Release the valve from the cistern 1.2.3 Rotate cup to unclip 1.2.4 Position cup to level 3 for 6/4 litres level 5 for 5/3.3 litres level 10 for 4/2.6 litres Cup shown at level 3 1.2.5 Rotate cup to re-clip Refit to base 1.2.6 Fit partitions to cistern For 6/4 litres - no partitions 5/3.3 litres - right hand partition 4/2.6 litres - both partitions Cup 5.8 - Re-assemble and turn on water supply. 5.2 - Empty cistern. 5.3 - Remove inlet valve as shown above. 4.8- Ensure the float chamber is in position shown. If necessary press tabs to reposition Float chamber Tabs Tabs on lowest position 164 SISLF323990 11644 iss C 1.4 - Fit the Vantage cistern onto the mounting brackets and clamp in position with the clips. Ensure the partition clip is fully home 5.7 - Clean sealing face of valve body. Sealing Face 5.4 - Release flushvalve from base. Rotate anti-clockwise to stop and lift out 5.1 - Turn off water supply. 5.5 - Remove flush valve from cistern 2 4.4 - Detach inlet valve from clip and pull to the right. 1 4.6 - Remove front nut. Front nut Filter key Filter assembly 1 2 3 4.7- Remove filter from valve, wash with clean water and re-assemble. Ensure chamber plug is in place 4.9 - Replace inlet valve, turn on water supply, and check water level. 4.5 - Manoeuvre valve through service aperture. Take care not to dislodge the chamber plug Vantage cistern Complete with flush valve, inlet valve, isolating valve and flow restrictor Push button (Style may vary) Pushfit elbow Clear tube - 750mm Mounting bracket and Clip x 2 Partition x 2 (Not supplied with 6L Mono) Green tube - 750mm (Dual flush only) Pushfit flushpipe Pan Connector Thomas Dudley Ltd PLASTIC CISTERN MANUFACTURERS Dauntless Works, P.O.Box 28, Birmingham New Road, Dudley, West Midlands, DY1 4SN Telephone: 0121 530 7000 Fax: 0121 557 5345 E-mail: [email protected] Important: Only use genuine Dudley spares or replacement parts

Upload: others

Post on 22-Nov-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 11644 iss C Vantage 2 Instructions

( Please leave this instruction leaflet with the end user)

INSTRUCTION LEAFLET

1 - Fitting the Vantage cistern -

5 - Maintenance of the outlet valve -

5.6 - Wash seal in clean water.

1.1 - Prior to installation ensure there is sufficient room for the Vantage and any support frame, push button etc. to be fittedwithout interference.

155 min

460

369 F

rom

to

p o

f flu

shp

ipe

101

328 max

740 m

ax

440 m

in

320 -

360

BS

EN

37

Optimum button position

1.3 - Fitting the mounting brackets

1.3.1 Position the templateand mark holes,ensuring it is level

1.3.2Drill holes to suitNo 8 csk screw(not supplied)

1.3.3Fit the mountingbracket and clips

1.2. Changing the capacity of the cistern (if required)

1.2.2 Release the valvefrom the cistern

1.2.3 Rotate cupto unclip

1.2.4 Position cup tolevel 3 for 6/4 litreslevel 5 for 5/3.3 litreslevel 10 for 4/2.6 litres

Cup shownat level 3

1.2.5Rotate cup to re-clipRefit to base

1.2.6Fit partitions to cisternFor 6/4 litres - no partitions5/3.3 litres - right hand partition4/2.6 litres - both partitions

Cup

5.8 - Re-assemble and turn on watersupply.

5.2 - Empty cistern. 5.3 - Remove inlet valve as shownabove.

4.8- Ensure the float chamber is in position shown. If necessary press tabs to reposition

Floatchamber

Tabs

Tabs onlowest position

164

SISLF323990 11644 iss C

1.4 - Fit the Vantage cistern onto the mounting brackets and clamp in position with the clips.

Ensure the partitionclip is fully home

5.7 - Clean sealing face of valve body.

Sealing Face

5.4 - Release flushvalve from base.

Rotate anti-clockwiseto stop and lift out

5.1 - Turn off water supply.

5.5 - Remove flush valve from cistern

2

4.4 - Detach inlet valve from clip andpull to the right.

1

4.6 - Remove front nut.

Front nut

Filterkey

Filterassembly

12

3

4.7- Remove filter from valve, wash with clean water and re-assemble.

Ensure chamber plugis in place

4.9 - Replace inlet valve, turn onwater supply, and check water level.

4.5 - Manoeuvre valve through service aperture.

Take care not todislodge the chamber plug

Vantage cisternComplete with flush valve, inlet valve,

isolating valve and flow restrictor

Push button(Style may vary) Pushfit elbow

Clear tube - 750mm

Mounting bracket and Clip x 2

Partition x 2(Not supplied with 6L Mono)

Green tube - 750mm(Dual flush only)

Pushfit flushpipe

Pan Connector

Thomas Dudley LtdPLASTIC CISTERN MANUFACTURERSDauntless Works, P.O.Box 28, Birmingham New Road, Dudley, West Midlands, DY1 4SNTelephone: 0121 530 7000 Fax: 0121 557 5345E-mail: [email protected]

Important: Onlyuse genuineDudley sparesor replacementparts

Page 2: 11644 iss C Vantage 2 Instructions

40

FIXING HOLE GUIDE

Centre of cistern

Top of cistern

23440

USE OF FLOW RESTRICTOR

TANK FED

MAINS FED

DIM ‘ X ‘ >50 FEET

DIM ‘ X ‘ <50 FEET

PRESSURE >1.5 BAR (25PSI)

PRESSURE <1.5 BAR (25PSI)

No sealing compound, paste, flux or solvent to be used in contact with plastic or rubber surfaces, to avoid damage to plastic components. Rubber washers / ‘O’ rings should provide adequate seal. PTFE tape may be used on threads. Do not overtighten plastic nuts. No chemical block / additive to be put in this cistern.

FINAL INSTALLATION CHECK LIST.- Check all moving components operate freely and the inlet valve shuts off correctly.- If overflowing or poor flushing subsequently occurs, first check that the float and arm move freely up and down and the water level is correct.- Check all joints are tightened correctly. - Check carefully for leaks.- Hold the inlet valve float down, causing the cistern to internally overflow. Ensure the warning pipe is capable of discharging all incoming water, without the cistern overflowing. If water does overflow make sure the flow restrictor is fitted. If overflowing persists, contact Technical Help at Thomas Dudley Ltd. 0121 530 7032

Dim

‘X’

3.2 - Use of the flow restrictor (restrictor is factory fitted).

3.4 - Bottom Entry Cisterns

4 - Maintenance of the inlet valve -

3.3 - Fit the pushfit elbow until fully home to the stop(can be connected to 15mm plastic pipe with insertor copper pipe).

A servicing valve shouldbe fitted at or near thetail of the inlet valve

WARNING !

2.1.2 - Measure dimension ‘A’.

2 - Fitting the flushpipe -

2.1 - Push the pipe onto the spigot over the 2 ‘O’ rings.

70 - 370 mm

Dim ‘A’

2.1.3 - Remove the pipe and cut dim ‘A’ from the larger diameter end of the pipe. Ensure pipe is cut straight and is free from burrs.

WARNINGDo not cut pipeless than 70mm

70-370 mm

90

2.2 - Re-fit the pipe onto the cistern over the 2 ‘O’ rings.

Dim ‘A’

4.2 - Turn off water supply. 4.3 - Release the inlet valve mounting clip

Mounting ClipOpen

Closed

3.1 - The Vantage cistern comes as standard with an internal isolating valve (factory set to closed).

3 - Plumbing the cistern -

4.1 - Remove service cover

3.6 - Check the water level - Adjust slightly if necessary by rotating the float. Ensure the float chamber is in the position shown

Water level

Floatchamber

Tabs

Tabs onlowest position

3.5 Fitment of partitions

Dual Flush6/4 Litre - No Partitions5/3 Litre - One Partition4/2.6 Litre - Two Partitions

Mono Flush6 Litre - No Partitions5 Litre - One Partition4 Litre - Two Partitions