111115 - kalkulasi - additional

Upload: muhamad-fadli-arsyada

Post on 08-Mar-2016

221 views

Category:

Documents


0 download

DESCRIPTION

Kalkulasi untuk proses perhitungan pressure safety valve

TRANSCRIPT

  • Control Valve Calculation Sheet 1 / 3Page

    Model ACN Nominal size 8 in. Port size 6 in.

    Rated CV 330

    Rating ANSI600 Flow characteristic INEAR(EQ% by POSITIONER

    10 in. 10 in.14014025.425.4

    GAS Fluid name

    MAX Flow rate 80 Inlet pressure 26 Outlet pressure 20 Differential pressure Temperature 77.66 Gravity/Density(Liquid) Gravity/Density(Gas or Vaper) 16.246487 Viscosity 0.011709 Vapor pressure

    Specific heat ratio 1.372878 Compression factor 0.950727 Flash

    Saturated temperature Reynolds number factor 1 Differential pressure ratio 0.2221

    0.0909

    Sound pressure level 76

    Calculated CV 248

    Travel 70

    94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9995 x 2701kPa x 0.903 x Sqr(0.2221)

    NOR603020

    77.66

    16.2464870.011709

    1.3728780.950727

    10.3224

    0.06817

    77

    140.5

    42

    374020

    77.66

    16.2464870.012135

    1.4395040.915442

    10.4877

    0.04106

    80

    55.83

    20

    70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

    43660m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)22.5 x 1 x 4101kPa x 0.8086 x Sqr(0.4877)

    Valve specification

    Process data

    Calculated value

    MIN

    Upstream Downstream Piping specification

    MMscfdbarG

    bardegF

    kg/m3MWcP

    barA

    %

    Mach

    barG

    degF Factors

    Unit

    %

    dBA

    (inch)(inch) (inch)

    (mm)

    =

    =

    =

    =

    =

    =

    248

    140.5

    55.83

    Item No. 19 Tag No. PCV-WRU-A/B

    Size Sch No. Thickness

    Ref No. Purchaser PT. PRATIWI PUTRI SULUNG End User PT. PGN Project PCV & PSDV WARU

    PCV

    Service Case 1 - 11/11/15

    barA Critical pressure

    Condition 1

    Outlet velocity

    A calculation result may be different from an actual case depending on the piping and operation conditions. It should be an reference data, accordingly.

    0 50 100Travel %

    0

    50

    100CV% Typical flow characteristic graph

    MAX

    NOR

    MIN

    Unit

    Azbil Corporation

    CV

    CV

    CV

    11/11/2015

  • Control Valve Calculation Sheet 2 / 3Page

    Model ACN Nominal size 8 in. Port size 6 in.

    Rated CV 330

    Rating ANSI600 Flow characteristic INEAR(EQ% by POSITIONER

    10 in. 10 in.14014025.425.4

    GAS Fluid name

    MAX Flow rate 80 Inlet pressure 40 Outlet pressure 20 Differential pressure Temperature 77.66 Gravity/Density(Liquid) Gravity/Density(Gas or Vaper) 16.246487 Viscosity 0.011709 Vapor pressure

    Specific heat ratio 1.372878 Compression factor 0.950727 Flash

    Saturated temperature Reynolds number factor 1 Differential pressure ratio 0.4877

    0.0909

    Sound pressure level 84

    Calculated CV 125.1

    Travel 38

    94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9999 x 4101kPa x 0.795 x Sqr(0.4877)

    NOR603020

    77.66

    16.2464870.011709

    1.3728780.950727

    10.3224

    0.06817

    77

    140.5

    42

    132320

    77.66

    16.2464870.012135

    1.4395040.915442

    10.1249

    0.01443

    61

    56.29

    20

    70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

    15340m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)22.5 x 1 x 2401kPa x 0.951 x Sqr(0.1249)

    Valve specification

    Process data

    Calculated value

    MIN

    Upstream Downstream Piping specification

    MMscfdbarG

    bardegF

    kg/m3MWcP

    barA

    %

    Mach

    barG

    degF Factors

    Unit

    %

    dBA

    (inch)(inch) (inch)

    (mm)

    =

    =

    =

    =

    =

    =

    125.1

    140.5

    56.29

    Item No. 20 Tag No. PCV-WRU-A/B

    Size Sch No. Thickness

    Ref No. Purchaser PT. PRATIWI PUTRI SULUNG End User PT. PGN Project PCV & PSDV WARU

    PCV

    Service Case 1 - 11/11/15

    barA Critical pressure

    Condition 1

    Outlet velocity

    A calculation result may be different from an actual case depending on the piping and operation conditions. It should be an reference data, accordingly.

    0 50 100Travel %

    0

    50

    100CV% Typical flow characteristic graph

    MAXNOR

    MIN

    Unit

    Azbil Corporation

    CV

    CV

    CV

    11/11/2015

  • Control Valve Calculation Sheet 3 / 3Page

    Model ACN Nominal size 8 in. Port size 6 in.

    Rated CV 330

    Rating ANSI600 Flow characteristic INEAR(EQ% by POSITIONER

    10 in. 10 in.14014025.425.4

    GAS Fluid name

    MAX Flow rate 80 Inlet pressure 40 Outlet pressure 20 Differential pressure Temperature 77.66 Gravity/Density(Liquid) Gravity/Density(Gas or Vaper) 16.246487 Viscosity 0.011709 Vapor pressure

    Specific heat ratio 1.372878 Compression factor 0.950727 Flash

    Saturated temperature Reynolds number factor 1 Differential pressure ratio 0.4877

    0.0909

    Sound pressure level 84

    Calculated CV 125.1

    Travel 38

    94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9999 x 4101kPa x 0.795 x Sqr(0.4877)

    NOR603020

    77.66

    16.2464870.011709

    1.3728780.950727

    10.3224

    0.06817

    77

    140.5

    42

    152420

    77.66

    16.2464870.012135

    1.4395040.915442

    10.1599

    0.01664

    64

    55.92

    20

    70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

    17700m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)22.5 x 1 x 2501kPa x 0.9372 x Sqr(0.1599)

    Valve specification

    Process data

    Calculated value

    MIN

    Upstream Downstream Piping specification

    MMscfdbarG

    bardegF

    kg/m3MWcP

    barA

    %

    Mach

    barG

    degF Factors

    Unit

    %

    dBA

    (inch)(inch) (inch)

    (mm)

    =

    =

    =

    =

    =

    =

    125.1

    140.5

    55.92

    Item No. 21 Tag No. PCV-WRU-A/B

    Size Sch No. Thickness

    Ref No. Purchaser PT. PRATIWI PUTRI SULUNG End User PT. PGN Project PCV & PSDV WARU

    PCV

    Service Case 1 - 11/11/15

    barA Critical pressure

    Condition 1

    Outlet velocity

    A calculation result may be different from an actual case depending on the piping and operation conditions. It should be an reference data, accordingly.

    0 50 100Travel %

    0

    50

    100CV% Typical flow characteristic graph

    MAXNOR

    MIN

    Unit

    Azbil Corporation

    CV

    CV

    CV

    11/11/2015