11/02/21 - assets.grenfelltowerinquiry.org.uk

6
External Facades to Tall Buildings - Routes to Compliance Steve Evans Building Control Alliance ) Building Regulations 1 Health and Safety not property protection Part B - Life safety Responsibility for compliance Person carry out the work BCB - help builder to achieve compliance 1 Final certificate does not guarantee compliance 11/02/21 External Facades to Tall Buildings - Routes to Compliance Programme , Requirements of the building regulations ; Development of BCA understanding , Risks to industry 1 Overview of BCA Guidance Note 18 ; Our experience to date Building Regulations ' For buildings with a ftoor over !Sm guidance In ADB2 (Para 12. 7) and 859991 (5ection 18.2) both require - tDTI --- All major components (lndudinc;J cladcling fmlshes) within_ wall construction to be •materials of lirnJted combustibility•, or The proposed wall build up shouki meet the performance cntena of BRE Report BR135 ror cladding systems using full scale test data from BS 6414-1 or BS 8414-2 Fire testing of curtain walling systems can rollow the recommendations in BS EN 13830:2015 Curtain Walling - Product Standard. BS EN 13830: 2015 directly requires testing of all curtain walling to BS EN1364 -4:2014 for fire Compartmentatlon - 1 MET00080639_0001 MET00080639/1

Upload: others

Post on 28-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 11/02/21 - assets.grenfelltowerinquiry.org.uk

External Facades to Tall Buildings -Routes to Compliance

Steve Evans Building Control Alliance

)

Building Regulations

1 Health and Safety not property protection

Part B - Life safety

Responsibility for compliance

Person carry out the work

BCB - help builder to achieve compliance

1 Final certificate does not guarantee compliance

11/02/21

External Facades to Tall Buildings -Routes to Compliance

Programme

, Requirements of the building regulations

; Development of BCA understanding

, Risks to industry

1 Overview of BCA Guidance Note 18

; Our experience to date

Building Regulations

' For buildings with a ftoor over !Sm guidance In ADB2 (Para 12. 7) and

859991 (5ection 18.2) both require -

tDTI ---

All major components (lndudinc;J cladcling fmlshes) within_ wall construction to

be •materials of lirnJted combustibility•, or

The proposed wall build up shouki meet the performance cntena of BRE

Report BR135 ror cladding systems using full scale test data from BS 6414-1

or BS 8414-2

Fire testing of curtain walling systems can rollow the recommendations in BS

EN 13830:2015 Curtain Walling - Product Standard.

BS EN 13830: 2015 directly requires testing of all curtain walling to BS EN1364

-4:2014 for fire Compartmentatlon

-

1

MET00080639_0001 MET00080639/1

Page 2: 11/02/21 - assets.grenfelltowerinquiry.org.uk

Building Regulations

85 8414-1 (masonry backing) or BS 8414-2 (LWSF bad<ing) full size tests

Development of BCA Understanding

Questions raised by Building Control Bodies involved in high rise

projects about suitability of some Insulation types

PIR and PUR insulation boards

Preferred by the Industry due to their exemplary thennal

performance relatlve to their thickness, lightweight and

reasonable cost.

Change In BBA certificate in late 2013 for most common product

seen on site restricted Its use on buildings with a noor over 18m

BCA recognised a need for f\Jrther industry guidance

Building Regulations

BR135 -

Performance criteria

An assessment ot the 658414 - 1/2

test

Risks to Industry

trr_a ~ ---

11/02/21

(~RICS

2

M ET00080639 _ 0002 MET00080639/2

Page 3: 11/02/21 - assets.grenfelltowerinquiry.org.uk

00 ---

Risks to Industry

; Prosecution under building control legislation Fines and imprisonment Loss or licence (Approved Inspectors)

1 Prosecution under health and safety legislation Corporate manslaughter Fines and Imprisonment

1 Civil Claims Fram people or relatives of injured or killed

, Claims on builders for delays or costs Reputational damage

Industry problem

BCA Guidance Note 18

Use of Combustible Cladding Materials on Buildings Exceeding 18m in height

; Option 1

Use Materials of Limited Combustibility

Cladding in accordance with Diagram 40

; Option 2

Testing to BS 8414-1/2 and meeting BR 135

criteria

~ @RICS

11/02/21

BCA Guidance Note 18

Use of Combustible Cladding Materials on Buildings Exceeding 18m In height

; Originally issued in June 2014

3 methods to demonstrate compliance

; Re-issued in June 2015 (Issue 1)

Revised to cover all buildings

4 methods to demonstrate compliance

1 Free to download from BCA website

@rues

(0

BCA Guidance Note 18

Use of Combustible Cladding Materials on Bulldlngs Exceeding 18m in height

1 Option 3

Fire engineered assessment of dadding based on test

data

Carried out by suitably qualified fire engineer

Based on reasoned arguments/facts not opinion

Demonstrate equivalence of performance of a BR135

compliant system

h\7'~ ... _ ... _ ....._,.,, ~'b:.~ -cabe acai "

3

MET00080639_0003 MET00080639/3

Page 4: 11/02/21 - assets.grenfelltowerinquiry.org.uk

Qr) --

BCA Guidance Note 18

Use of Combustible Cladding Materials on Buildings Exceeding 18m In height

Option 3

Should use test data which is specific to the product(s)

which are proposed.

Should justify any discrepancies between the tested and

proposed build-ups

Avoid leaps of faith! Applying data from very dissimilar

materials can lead to Inaccurate conclusions.

. ... _ .. acai @RICS

()

BCA Guidance Note 18

Use of Combustible Cladding Materials on Buildings Exceeding 18m In height

; Option 4

Equivalence with BR135 parameters of Ore spread (600°C

at Sm above the opening after 15 minutes)

Needs to consider external fire risks and risks from

ancillary accommodation

Sprinklers alone aren't the complete answer!

Inform Responsible Person under Regulation 38

11/02/21

BCA Guidance Note 18

Use of Combustible Cladding Materials on Buildings Exceeding 18m In height

Option 4

Holistic fire engineered assessment of whole building

Carried out by suitably qualiOed fire engineer

Take into account all building factors

Demonstrate that building provides reasonable provision

for life safety

May be necessary to adapt the building ,, __

Glazed Systems

Complete glazed systems would meet guidance as MOLC

Difficulties arise with spandrel panels using combustible

insulation, especially where running full height of building.

No testing (that we are aware of) which demonstrates how

this configuartlon will react.

Are testing af curt.a~ walllng svstem!i cao ro11ow the recommendations In

BS EN 13830:2015 Curtain Wallino - Product Standard.

85 EN 13830:2015 directly requil'l!S testing of all aJrtaln walling to 85

EN1364-4:2D14 for fire Compartm@ntation

@RICS

4

MET00080639_0004 MET00080639/4

Page 5: 11/02/21 - assets.grenfelltowerinquiry.org.uk

Glazed Systems

BCA Experience

Positives

; Adoption of BCA GN 18 as industry best practice by

BCB's and Warranty bodies

, Experience and understanding of builders is becoming

more common

, Pre-design discussions with builders about facades are

becoming more common

tp_n __ ... ______ _ ~ ~ la: ~ @RICS

(

11/02/21

Glazed Systems

At present no evidence to prove Option 1 or Option 2

compliance

Option 3 Assessments

Build up of spand~s/type of insulation

Option 4 Assessments

Location of spandrels/Jsolatton/compartmentatlon

~~-~--"

I

BCA Experience

Not so Positives Reports from some fire engineers still based on opinion not

fact

Cavity closers to all openings

, Limited number of published tests available

No tests using lightweight metal claddings

Lack of Curtain walling tests being provided to NHBC as

justification.

Substitution of materials

tQu ~-~------

5

M ET00080639 _ 0005 MET00080639/5

Page 6: 11/02/21 - assets.grenfelltowerinquiry.org.uk

External Facades to Tall Buildings -Routes to Compliance

External Facades to Tall Buildings -Routes to Compliance

Summary

' Requirements of the building regulations

, Development of BCA understanding

; Risks to industry

, Overview of BCA Guidance Note 18

Our experience to date

kr"'I __ ... __ .. IJLl..c...A ""'tabe acai .• , .._.__ -~

Metropolitan Police Station

EsitE v ' 4-- Cust No. Serial No.

MPSZ13185217 Ex. Book No. 1 OCU: Other Stn. Ref. Lab Ref. No .

. ~~~.~~~~'. .. ·:::~:~:.::::: : :: ::::::::::::: :: ::: :::::::::::::::

.. ........... ............... .... {::J ............... ............... 5..2., ............................ . Taken by~~.~ ... l' .. ~~ ...... oa:?l...,, .......... Time: .............. ..

Sealed by:f.?.~~ .. f.Y ..... ~ .. Dat~J ..... ~ ... . Time: .............. ..

I IDENTIFY THIS EXHIBIT AS THAT REFERRED TO IN MY STATEMENT

~~ Signature: .. .. .... ............................... ::::: ...... .. ...................................... .

Signature(s) of additional witness(es)

····················f:····· .. ······················································ .. ········· .. ············ ....................... . . ....... ........... .. ..................................................... .

:::::::::::::::::::::: ... :::: .::: ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: MP 1404/04 MPSZ13185217 Form 4208

I llllllll lllll lllll II llllll lllll lllll 111111111111111111111111111111111

---

11/02/21

6

M ET00080639 _ 0006 MET00080639/6