06/15/22 Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation Lengths Propagation Time Comparison of PM and SiPM Detectors Time Resolution measurements

Upload: cori-wilcox

Post on 21-Jan-2016

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

04/21/23 Collaboration Meeting Feb 2011 Start Counter

1

Start Counter Update

W. U. Boeglin

L. Guo

E. Pooser

• Measurements on EJ-212 scintillator bars • Attenuation Lengths• Propagation Time • Comparison of PM and SiPM Detectors

• Time Resolution measurements

Page 2: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

EJ-212 Scintillator Bar

04/21/23 Collaboration Meeting Feb 2011 Start Counter

2

• Dimensions: 12,15 mm x 600 mm: thicknesses: 2, 3 mm• With and without a VM2000 backing, mounted in dark box• PMT and SiPM touches end of scintillator• Used 90Sr source

Light output measurements: Scintillator

Trigger Detector

PM or SiPM

Page 3: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

04/21/23 Collaboration Meeting Feb 2011 Start Counter

3

Attenuation Length3 x 15 x 600 (mm)

Fit Range (20 – 50 cm)

No VM2000 Backing VM2000 Backing

Page 4: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Attenuation Lengths Summary

04/21/23 Collaboration Meeting Feb 2011 Start Counter

4

• The attenuation lengths are much improved as compared to the EJ-200 bars

• Due to better manufacturing and diamond-milled edges

• On average, with VM2000 placed at the end of the scintillator, we see a factor 1.6 better attenuation length

Scintillator Dim. No VM Backing VM Backing

2 x 15 x 600 (mm) 81.2 cm 135 cm

3 x 12 x 600 (mm) 50.8 cm 76.2 cm

3 x 15 x 600 (mm) 69.6 cm 125 cm

Page 5: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

O’Scope Images (SiPM): Source Close to Detector

04/21/23 Collaboration Meeting Feb 2011 Start Counter

5

No VM2000 BackingVM2000 Backing

• VM Backing has factor 1.2 Larger signal size • Poor fall time for SiPM ~ 17 – 20 (ns)

FMPMT Trigger

FMPMT Trigger

SiPMSiPM

Page 6: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

O’Scope Images (SiPM): Source Far From Detector

04/21/23 Collaboration Meeting Feb 2011 Start Counter

6

No VM2000 BackingVM2000 Backing

• VM Backing has factor 1.6 Larger signal size• No VM signal size when close is factor 1.9 larger than when far away• VM signal size when close is factor 1.4 larger than when far away

FMPMT Trigger

SiPMSiPM

FMPMT Trigger

Page 7: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Propagation Time of Light in the scintillator bars

04/21/23 Collaboration Meeting Feb 2011 Start Counter

7

Page 8: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Comparison of Detector Time Resolutions (PM vs. SiPM)

3 x 15 x 600 (mm)

04/21/23 Collaboration Meeting Feb 2011 Start Counter

8

SiPM

SiPM

PMTPMT

No VM2000 Backing VM2000 Backing

Page 9: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Comparison of Detector Time Resolutions (PM vs. SiPM) Summary

04/21/23 Collaboration Meeting Feb 2011 Start Counter

9

• Time Resolution gets worse in the 25 – 45 (cm) range when measured with the PM and bars have VM2000 backing This is not the case when measured with the SiPM

• σ(SiPM) ≈ 2.3 * σ(PMT)

Scint. Dim. (mm)

SiPM (No VM) (ps)

PM (No VM) (ps)

SiPM (VM) (ps)

PM (VM) (ps)

2 x 15 x 600 800 < σ < 1000 300 < σ < 350 720 < σ < 820 300 < σ < 400

3 x 12 x 600 500 < σ < 700 300 < σ < 360 500 < σ < 600 300 < σ < 400

3 x 15 x 600 550 < σ < 650 220 < σ < 300 520 < σ < 550 270 < σ < 320

Page 10: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Time Resolution Comparison (No VM2000 Backing)

04/21/23 Collaboration Meeting Feb 2011 Start Counter

10

PMT SiPM

3x15

2x153x12 & 2x15

3x12

3x15

Page 11: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

04/21/23 Collaboration Meeting Feb 2011 Start Counter

11

Time Resolution Comparison(With VM2000 Backing)

PMT SiPM

3x15

2x153x12 & 2x15

3x15

3x12

Page 12: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Time Resolution Comparison Summary

04/21/23 Collaboration Meeting Feb 2011 Start Counter

12

• The 2 x 15 (mm) bar has the worst time resolution with the SiPM

• The 3 x 12 (mm) and the 3 x 15 (mm) bars have approximately the same time resolutions with SiPM

• The 3 x 15 (mm) has the best time resolution

Page 13: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Summary

04/21/23 Collaboration Meeting Feb 2011 Start Counter

13

• Further measurements need to be made concerning the

SiPM

• Cooling of SiPM so as to reduce noise and improve

timing measurements

• Full wrapping of the 3mm bars with VM2000 (or similar

highly reflective material)

•Begin testing of scintillator coupled to light guide

Page 14: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Attenuation Length2 x 15 x 600 (mm)

Fit Range (20 – 50 cm)

04/21/23 Collaboration Meeting Feb 2011 Start Counter

14

No VM2000 Backing VM2000 Backing

Page 15: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

04/21/23 Collaboration Meeting Feb 2011 Start Counter

15

Attenuation Length3 x 12 x 600 (mm)

Fit Range (20 – 50 cm)

No VM2000 Backing VM2000 Backing

Page 16: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Comparison of Detector Time Resolutions (PM vs. SiPM)

2 x 15 x 600 (mm)

04/21/23 Collaboration Meeting Feb 2011 Start Counter

16

Page 17: 1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation

Comparison of Detector Time Resolutions (PM vs. SiPM)

3 x 12 x 600 (mm)

04/21/23 Collaboration Meeting Feb 2011 Start Counter

17