10398 pacific center court san diego, ca · 10398 pacific center ct. building specs property...
TRANSCRIPT
1 0 3 9 8 P a c i f i c C e n t e r C o u r t
S a n D i e g o , C A
features
Dock-High & Grade Level Loading
Property & Building Enhancements Completed
Robust Labratory Infrastructure
Prominent Building Top and Monument Signage Opportunities
Parking Ratio of 2.5-3.0/1,000 SF (Potentially Expandable) 4 EV Charging Stations
Located near top San Diego Life Science & Telecommunications Companies
PLUG AND PLUG AND PLAY LABPLAY LAB
INTERIORINTERIORBUILDING BUILDING PHOTOSPHOTOS
DRAMATIC DRAMATIC CREATIVE OFFICE CREATIVE OFFICE
OPPORTUNITYOPPORTUNITY
MULTI-TENANT LOBBY // CONCEPTUAL RENDERINGMULTI-TENANT LOBBY // CONCEPTUAL RENDERING
OUTDOOR LOUNGE // CONCEPTUAL RENDERINGOUTDOOR LOUNGE // CONCEPTUAL RENDERING
17h f f l p . c o mP R O P E R T Y D E S C R I P T I O N S
PACIFIC CENTER COURT
PACIFIC CENTER BLVD
projec t aer ia lFive Buildings Totaling Approx. 330,000 SF
1 0 3 9 8 P A C I F I C C E N T E R C T .
1 0 3 9 4
1 0 4 2 1
1 0 4 4 5
N
1 0 3 9 0
h f f l p . c o m16
SCIENCE & INNOVATIONp o r t f o l i o
P R O P E R T Y D E S C R I P T I O N S
10421 Pacific Center Ct
PACI
FIC
CEN
TER
BLV
D
PACIFIC CENTER CT
SITE PLAN
10
44
5 P
acific
Ce
nte
r C
t
10394 Pacific Center Ct
10
39
8 P
acific
Ce
nte
r C
t
10
39
0 P
acific
Ce
nte
r C
t
Towards Amenities &
Freeways
N
s i te plan
5 BUILDING 5 BUILDING CAMPUS TOTALING CAMPUS TOTALING
APPROXIMATELY APPROXIMATELY 315,000 SF315,000 SF
Dock Loadingas-bui l tf loor plans
5 9 , 2 9 1 S F
Second floor office improvements above functional ground floor lab spaces
Dock-high and grade level loading options
High-quality existing lab improvements and infrastructure on the 1st floor
Back-up generator in place in dedicated utility enclosure
Multiple sets of restrooms with shower and locker facilities
The high bay orientation of the building provides the ability to create open office areas floor to roof heights over 30.0’
Primary Entrance
SCALE:--
10398 PACIFIC CENTER CT. FIRST FLOOR PLAN1/8" = 1'-0"
10/25/2018
Patio w/roll up door
f i rst f loor43,110 s f
second f loor16,181 s f
Grade Loading
Open To Below
SCALE:--
10398 PACIFIC CENTER CT. SECOND FLOOR PLAN1/8" = 1'-0"
10/23/201810/25/2018
s ingle tenant hypothet ical f loor plan
LOBBY
LAB
OPENOFFICE
CONF. CONF.
LABSUPPORT
CONF.
LABSUPPORT
DEMONSTRATIONLAB
CONF.
BREAKROOMJAN
SERVER
(E)
ELEC
. RM
LABSUPPORT
LABSUPPORT
LABSUPPORT
LABSUPPORT
LABSUPPORT
OFFICE
LABSUPPORT
LABSUPPORT
LABSUPPORT
LAB
LABSUPPORT
LAB
LABSUPPORT GLASSWASH/
AUTOCALVE
WAREHOUSE
ELECTRICAL
INSPECTION
OUTDOORPATIO
LOADING ATGRADE
LOADING ATGRADE
f i rst f loor
second f loor
CONF.CONF.
COPY/PRINT
OFFICE OFFICE OFFICE OFFICEOFFICE
COPY/PRINT
OPENOFFICE
CO
PY/P
RIN
T
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICEOFFICEOFFICEOFFICEOFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
t wo -tenant hypothet ical f loor plan
TENANT 1TENANT 1± 31,987 RSF
TENANT 2TENANT 2± 27,301 RSF
LABSUPPORT
LABSUPPORT
LABSUPPORT
OPENOFFICE
CO
PY/P
RIN
T
TENANT 1LOBBY TENANT 2
LOBBY
LABSUPPORT
LABSUPPORT
CONF.
LABSUPPORT
LABSUPPORT
LABSUPPORT
LAB
CONF.
COPY/PRINT
BREAKROOM
OPENOFFICE
(E)
ELEC
. RM
JAN
SERVER
BREAKROOM COMMON
LOBBY
CONF.
LABSUPPORT
LABSUPPORT
LABSUPPORT
LABSUPPORT
LABSUPPORT
LABSUPPORT
GLASSWASH/AUTOCLAVE
LAB
LABSUPPORT
LABSUPPORT
344 SF
LAB
OFFICE OFFICE OFFICE OFFICE OFFICE
WAREHOUSE
LOADING ATGRADE
ELECTRICAL
LOADING ATGRADE
INSPECTION
OUTDOORPATIO
OUTDOORPATIO
f i rst f loor
second f loor
CONF.
OFFICE OFFICE OFFICE OFFICEOFFICE
COPY/PRINT
OPENOFFICE
CONF.OFFICE
OPENOFFICE
CO
PY/P
RIN
T
OFFICE OFFICE OFFICEOFFICEOFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE OFFICEOFFICEOFFICE
TENANT 1
TENANT 2
1 0 3 9 8 P A C I F I C C E N T E R C T .
bui ld ing specs
P R O P E R T Y O V E R V I E W D E S I G N & C O N S T R U C T I O N
GENERAL
TYPE OF CONSTRUCTION Type III, Concrete Tilt-Up Panels
SLAB TO SLAB HEIGHT 11’11” (First Floor) / 12’2” to 16’8” (Second Floor) / 30’2” (Warehouse)
ROOF
ROOF CONSTRUCTION Built Up Roof Membrane
ELEVATORS
OVERVIEW 1 (in process)
FIRE, LIFE, SAFETY
FLS SYSTEM N/A
SPRINKLERED Full Sprinklered
ELECTRICAL
AMPS 2500 AMPS
VOLTS 480 / 277 Volts, 3 Phase
BACKUP POWER 300-350 kW Generator, 480 Volts, 3 Phase
SECURITY
OVERVIEWSecurity card access system and routine patrol by a security guard service
PARKING
PARKING RATIO 3.0 per 1,000 SF (multiple electric charging stations)
UTILITIES
POWER SDG&E
GAS SDG&E
WATER/SEWER City of San Diego
YEAR BUILT 1985 (Renovated 2019)
NUMBER OF STORIES 2
NRA (BOMA) 59,291 SF (Divisible)
ZONING IL-2-1
ESTIMATED NNN’s $0.45 (2020 Estimate)
SPACE CONDITION
Combination of functional existing lab improvements and warm-shell condition areas with some high-bay, warehouse capacity
SIGNAGEBuilding and monument signage available
PROPERTY MANAGEMENT
JLL
1 0 3 9 8 P A C I F I C C E N T E R C T .
bui ld ing specs
MECHANICAL SYSTEMS
AIR HANDLING SYSTEMS The lab spaces are served by six (6) air handling units all of which are located on the second floor. 1 Unit: 25,700 CFM, 50 HP; 2 Units: 3,050 CFM, 7.5 HP; 3 Units: 1,800 CFM, 5 HP
EXHAUST FANSThere are ten (10) utility set rooftop exhaust fans serving lab spaces and four (4) mushroom exhaust fans serving restrooms.
PACKAGED HEAT PUMPSThere are twenty four (24) rooftop packaged heat pumps and four (4) split system fan coils serving office spaces. 3-10 ton units, 2- 7 ton units, 2-6 ton units, 7-5 ton units, 5- 4 ton units, 5- 3 ton units, located on the roof.
HEATING HOT WATER SYSTEMThe heating hot water system consists of two (2) hydronic gas-fired boilers and four (4) pumps, all of which are located in west and east mechanical yard. The heating hot water system is piped throughout the building to the various reheat coils and air handlers. The heating hot water boiler and two (2) pumps in east mechanical yard are for backup.
CHILLED WATER SYSTEM
The chilled water system consists of one 80 ton Carrier air-cooled rotary screw chiller, and one 70 ton Carrier scroll chiller and four (4) chilled water pumps, all of which are located in mechanical yard. The chilled water system is piped throughout the building to the various air handlers. The 70 ton chiller and two (2) pumps in east mechanical yard are for backup.
STEAM SYSTEM There is one (1) 9.5 HP steam boiler located on the second floor.
HUMIDIFIER There is one (1) wall mounted humidifier located in the server room.
TEMPERATURE CONTROLS The building temperature controls is provided by Siemens.
LAB PLUMBING SYSTEMS AND EQUIPMENT
DOMESTIC HOT WATER SYSTEM Domestic hot water is provided to the restrooms by one (1) water heater located in east wing on the second floor.
INDUSTRIAL HOT WATERIndustrial hot water is provided by two (2) water heater’s one (1) located in the east wing and one (1) located on west wing on the second floor.
COMPRESSED AIR SYSTEMCompressed air is provided by one (1) 7.5 hp simplex compressor and a 25 cfm refrigerated dryer located in the east mechanical yard.
VACUUM SYSTEMVacuum is provided by a Busch 7.5 hp (2) duplex vacuum system with a 200 gallon receiver. Equipment is located in the west wing on the second floor.
DEIONIZED WATER Deionized water is provided by a Water Works 1” DI system with UV Disinfection.
NATURAL GAS Existing medium pressure gas system has an existing 3,000 cfh capacity gas meter.
1 0 3 9 8 P A C I F I C C E N T E R C T .
bui ld ing specs
ELECTRICAL SYSTEMS
SDGE ELECTRICAL SERVICE
Entrance sized at: 2500A 480V 3PH 4W
Two SDG&E meters:
Meter#1: 1200A meter section feeding ½ of the building including one central plant chiller
Meter #2: 1200A meter section feeding ½ of the building including one central plant chiller
Meter #3: 100A house meter feeding site and core items
SDG&E outdoor transformer is sized at 750KVA. This is sized for a load of 902A of building load. This is sized for the demand per SDG&E and can be replaced with a larger transformer if the building load increases. The SDG&E conduit to the building service is sized for the full 2500A capacity, but SDG&E has only installed a portion of the service based on past demand.
ELECTRICAL SWITCHGEAR AND CONDITION
This switchgear is located indoors and away from the elements. The two meters appear to split the building for two tenants, but these meters can be reused if a single tenant occupied the entire building. The switchgear has two 600A feeds to the chiller yard for an air cooled chiller. This appears to separate the building into separate HVAC systems, and matches the metering scheme.
ELECTRICAL DIESEL GENERATOR
The building is served by a single Kohler 300REOZDD Diesel backup generator sized at 300kW-350kW. Each electrical meter has a separate feed and ATS to the generator. Each ATS is sized at 200A at 480V. These ATS’s are separate feeds to the generator but each ATS can call for generator start and each ATS can be energized separately. Each ATS is fed from the Diesel generator, but each ATS has a separate redundant switch to allow a temp generator to be connected. The generator is located outside next to the chiller yard. These connections are made via a Manual Selector Disconnect switch and junction boxes routed outside.
BUILDING TELEPHONE SERVICES AND MPOE LOCATION
The main building telephone backboard is NOT located in the SDG&E room. These services are located in the adjacent room and controlled separately.
OTHER ITEMS OF NOTE
AREA OF LABS There is approximately 11k square feet of intact lab space (some open lab with benches, some lab support space, some ISO classified rooms).
SINKS Approx. 18 remaining. Approx. 20 Credits remain for previously removed sinks.
WALK IN 2-8C walk in left in place Approx. 475sf
GLASS WASH EQUIPMENT The glass wash room with Autoclave and glasswasher is remaining.
N
Lopez CanyonOpen Space
Los Penasquitos Canyon Preserve
TO HWY-566 MILES
I-805 NORTH 3 EXITS 3 ENTRANCEI-805 SOUTH 3 EXIT 3 ENTRANCE
I-5 NORTH 1 EXITI-5 SOUTH 1 ENTRANCE
TO I-155.3 MILES
805INTERSTATE
5INTERSTATE
MIRA MESA BLVD
LUSK BLVD
CARROLL CANYON RDOBERLIN DR
VISTA SORRENTO PKWY
SORRENTO VALLEY RD
ROSELLE ST
HUENNEKENS ST
SORRENTO VALLEY BLVD
OCEAN AIR DR
CARROLL RD
NANCY RIDGE DR
SUM
MERS R ID
GE R D
FLA NDERS DR
SEQUENCE DR
PACIFIC HEIGHTS BLVD
PACIFIC CENTER BLVD
CAM
INO SANTA FE
3
1 1
1
7
1
8
1
2
2
4
29
3
3
33
44
5
6
5
11
6
72
4
10
4
5
67
8
2
12
13
PERSONAL SERVICES/SHOPPING HOTEL /TRAVEL1 Plaza Sorrento2 Premier Athletic & Squash Club3 Sorrento Canyon Golf Center4 Sorrento Court5 Sorrento Mesa Crossroads6 La Fitness7 Mesa Rim Climbing & Fitness Center
1 Courtyard by Marriott2 Extended Stay America3 Residence Inn by Marriott4 Hyatt House5 Holiday Inn Express6 Staybridge Suites7 Hertz8 Enterprise Rent-A-Car
RESTAURANTS1 8Elements Express2 Centerpark Café3 Gravity Heights Gastropub4 Wich Addiction5 Cornerstone Café6 Karl Strauss Brewing Company7 Sandwich House8 Come On In Café9 The WineSellar & Brasserie10 Urbane Café11 Naseem's Bakery & Kabob12 Q’s Cafe13 Q’s Cafe
BUSINESS SERVICES1 Staples2 FedEx3 Minuteman Press4 Public Storage
BANKS1 Bank of America2 Mission Federal Credit Union (ATM)3 San Diego County Credit Union4 Wells Fargo
area amenit ies
CBRE, Inc. | Broker Lic. 00409987
© 2020 CBRE, Inc. All rights reserved. This information has been obtained from sources believed reliable, but has not been verified for accuracy or completeness. You should conduct a careful, independent investigation of the property and verify all information. Any reliance on this information is solely at your own risk. CBRE and the CBRE logo are service marks of CBRE, Inc. All other marks displayed on this document are the property of their respective owners. Photos herein are the property of their respective owners. Use of these images without the express written consent of the owner is prohibited.
M A T T N I C K E L [email protected]
+1 858 646 4707
Lic. 01432593
R Y A N E G L [email protected]
+1 858 546 4648
Lic. 01445615
R O B M E R K I [email protected]
+1 858 546 4629
Lic. 00881080
1 0 3 9 8 P a c i f i c C e n t e r C o u r t
San Diego, CA