Parani-MSP1000 Firmware Upgrade v1.2.0 Notes
2008-05-20Sena Technologies
![Page 2: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/2.jpg)
2
Contents
• New Features– Repeater mode– Serial Hub mode– Vertex mode– Control Commands– Others
• Serial modem card support• VFAT support• Enhanced handling of Bluetooth FTP• RFC2217 support
• Bug Fix List
![Page 3: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/3.jpg)
3
Repeater Mode• New mode added to the list of Operation mode• Menu: Bluetooth -> Operation Mode• Parani-MSP1000 in Repeater mode can be used to function as
a Repeater in order to extend the range of Bluetooth transmission or avoid obstacles between Parani-MSP1000 and Bluetooth devices
• Manual 4.2.2 Repeater Mode > page 28
![Page 4: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/4.jpg)
4
Repeater ModeTypical Application:
– Extend the transmission range when there is an obstacle between MSP1000 and ESD100-embedded devices
– PC can manage both 3 ESD’s connected to the station and the other 3 ESD’s connected to the repeater at the same time
ESD1
ESD2
ESD3
MSP Repeater MSP Station
ESD4 ESD5 ESD6
PC
![Page 5: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/5.jpg)
5
Serial Hub mode• New mode added to the list of Service Category• Menu: Serial Port Profile -> Port configuration -> Service
Category• In Serial Hub mode, one SD connected to MSP1000 can
communicate with multiple SD’s connected to MSP1000 can communicate with each other, 1:N multi-serial connection
• Ideal for the cable replacement of RS422/485 Multi-Drop network
• Manual 5.5.4 & 5.5.8
Fig. Serial hub mode (SD A~D : Parani-SD100s)
SD A
SD D
SD C
SD B
![Page 6: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/6.jpg)
6
Serial Hub modeTypical Application:
– Cable replacement of Master/Slave type RS422/485 Multi-drop application when Master Device is stand-alone or network-disabled.
– Send the data from the scale to multiple PC’s
Scale PC A
PC B
PC C
Before : RS485 Multi-drop
Scale+SD SD+PC A
SD+PC B
SD+PC C
MSP
After : Serial Hub
Master Device Master Device
![Page 7: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/7.jpg)
7
Vertex mode• New mode added to the list of Network service mode• Menu
– Serial Port Profile -> Vertex configuration– Serial Port Profile -> Port configuration -> Network service -
> Network service mode• A configuration to send the data from the host to connected
Bluetooth devices• Manual 5.5.6 & 5.6
Datathrough Vertex port
Fig. Vertex mode
![Page 8: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/8.jpg)
8
Vertex modeTypical Application:
– Cable replacement of Master/Slave type RS422/485 Multi-drop application when Master Device is a PC or network-disabled.
– Send the message from the host PC to multiple signboards
PC(Master device)
Signboard
Before : RS485 Multi-drop
SD+SignboardMSP
Ethernet
Signboard
Signboard
SD+Signboard
SD+Signboard
After : Vertex mode
PC(Master device)
![Page 9: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/9.jpg)
9
Control commands• MSP1000 used to be monitored by Telnet, SSH and HTTP. In
order for MSP1000 to be monitored by programs, MSP1000 now supports TCP sockets through the port.
• The Parani-MSP1000 is controllable by Control commands through 2525 TCP port
• Available commands form Control port– USER admin - PASS admin– STAT - SCAN [IAC]– LIST - DISC [ID]– LOG [Line] - VER– HELP - REBOOT– QUIT
• Manual Appendix D
![Page 10: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/10.jpg)
10
Control commands• With PC-based program, users can monitor the status of
SD’s connected to MSP1000 and disconnect the Bluetooth connection.
PC SDMSPTCP 2525 port
SD
SD- Monitoring each module of MSP1000- Monitoring SD connection status-Disconnect Bluetooth connection-Logging
![Page 11: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/11.jpg)
11
Others• CF Serial modem card
– Support PPP communication through Serial modem– Manual 6.2 Serial modem card configuration– Supports modem list
• COMPAQ CFVFM-5614RD.• VFAT
– The Parani-MSP1000 supports VFAT (windows file system format) as CF Flash memory file format.
• Enhanced handling of Bluetooth FTP– When use Bluetooth FTP, you can choose CF Memory Card as Ba
se directory• RFC-2217(Telnet COM Port Control Protocol) Support
![Page 12: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/12.jpg)
12
Bug Fix List • Fixed the kernel panic problem occurring when the Parani-MSP1000 t
ransfers many data through bluetooth module • Fixed the problem that the Portlog was not displayed in the Web corr
ectly– SPP IN/OUT display error– Display error in Readable binary– Added Month / Date to the logging time
• Fixed the problem that the text of Portlog was not cleared– Portlog Clear error on Webpage
• Fixed the problem that the Portlog was not logged to CF card.
![Page 13: 1 Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies](https://reader036.vdocuments.us/reader036/viewer/2022082817/56649e6c5503460f94b6afc8/html5/thumbnails/13.jpg)
13
Bug Fix List • Fixed the problem that the syslogd logs '-- MARK --' to syslog server.• Fixed the problem that the Date and Time configuration was not set c
orrectly.– Daylight saving time support