• Hydronic heating systems rely on circulating water or steam to deliver heat to the remote locations where warming of a space is desired.
• Hydronic heating systems rely on circulating water or steam to deliver heat to the remote locations where warming of a space is desired.
![Page 3: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/3.jpg)
3Hydronic Heating Systems Hydronic Heating Systems
![Page 4: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/4.jpg)
4
Hydronic Heating SystemsHydronic Heating Systems
![Page 5: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/5.jpg)
5The Heat SourceThe Heat Source
• Heat energy is transferred from the heat source (burners) to the water in the boiler.
– There are two different types of boilers on the market today.
• High mass• Low mass
• Heat energy is transferred from the heat source (burners) to the water in the boiler.
– There are two different types of boilers on the market today.
• High mass• Low mass
![Page 6: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/6.jpg)
6
The Heat SourceThe Heat Source
• Cast iron (high mass) boilers are most commonly boiler found in residential applications.
– Residential cast iron boilers typically hold
between 10 - 15 gallons of water.
• Cast iron (high mass) boilers are most commonly boiler found in residential applications.
– Residential cast iron boilers typically hold
between 10 - 15 gallons of water.
![Page 7: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/7.jpg)
7
Cast iron (high mass) boilerCast iron (high mass) boiler
![Page 8: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/8.jpg)
8
Cast iron (high mass) boilerCast iron (high mass) boiler
• The boiler manufacturer supplies us with a booklet that is sent with the boiler.
• It is important that these instructions are followed when the boiler is installed.
• This booklet also contains information about proper boiler maintenance or troubleshooting.
• The boiler manufacturer supplies us with a booklet that is sent with the boiler.
• It is important that these instructions are followed when the boiler is installed.
• This booklet also contains information about proper boiler maintenance or troubleshooting.
![Page 9: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/9.jpg)
9
The Heat SourceThe Heat Source
• Stainless steel (low mass) boilers are gaining popularity due to the higher efficiencies being obtained today by many different manufacturers.
– Low mass boilers hold between 4 - 7 gallons of water.
• Stainless steel (low mass) boilers are gaining popularity due to the higher efficiencies being obtained today by many different manufacturers.
– Low mass boilers hold between 4 - 7 gallons of water.
![Page 10: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/10.jpg)
10
Low mass boilerLow mass boiler
![Page 11: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/11.jpg)
11
Hydronic controlsHydronic controls
• Thermostat
– The heating thermostat, whether it is a modern digital, snap action or mercury bulb type, is a close on temperature drop device.
• Thermostat
– The heating thermostat, whether it is a modern digital, snap action or mercury bulb type, is a close on temperature drop device.
![Page 12: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/12.jpg)
12
Thermostat typesThermostat types
• Digital Snap action Mercury bulb
• Digital Snap action Mercury bulb
![Page 13: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/13.jpg)
13Hydronic controlsHydronic controls
• Aquastat
– The Aquastat is a temperature-sensing switch that is responsible for cycling the boiler on and off to keep the water in the boiler close to the desired temperature.
– It may be strapped onto a pipe or immersed in the water via a well.
• Aquastat
– The Aquastat is a temperature-sensing switch that is responsible for cycling the boiler on and off to keep the water in the boiler close to the desired temperature.
– It may be strapped onto a pipe or immersed in the water via a well.
![Page 14: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/14.jpg)
14
Aquastat typesAquastat types
• Immersion Strap-on Triple • Immersion Strap-on Triple
![Page 15: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/15.jpg)
15
Low Water CutoffLow Water Cutoff
• The Low Water Cutoff is responsible for de-energizing the combustion operation in the event the water level in the system falls below the desired level established by the manufacturer.
• The Low Water Cutoff is a safety device that code officials require to be installed on all hydronic systems.
• The Low Water Cutoff can be a stand alone device or a built in part to the Aquastat.
• The Low Water Cutoff is responsible for de-energizing the combustion operation in the event the water level in the system falls below the desired level established by the manufacturer.
• The Low Water Cutoff is a safety device that code officials require to be installed on all hydronic systems.
• The Low Water Cutoff can be a stand alone device or a built in part to the Aquastat.
![Page 16: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/16.jpg)
16Low Water CutoffLow Water Cutoff
![Page 17: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/17.jpg)
17
High limit switchHigh limit switch
• Manual reset high limit switches are required in light commercial applications.
• Manual reset high limit switches are required in light commercial applications.
![Page 18: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/18.jpg)
18Circulator PumpsCirculator Pumps
• The circulator pump is used to move water throughout the hydronic system.
• The circulator pump is also called a centrifugal pump.
• The centrifugal pump is made up of a motor, a linkage and an impeller.
• The circulator pump is used to move water throughout the hydronic system.
• The circulator pump is also called a centrifugal pump.
• The centrifugal pump is made up of a motor, a linkage and an impeller.
![Page 19: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/19.jpg)
19
Circulator pump styles and brandsCirculator pump styles and brands
• Taco 007 Taco 110 Grundfoss • Taco 007 Taco 110 Grundfoss
![Page 20: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/20.jpg)
20
Circulator locationCirculator location
• Early circulators were large and heavy. The easiest place to mount them was on the return piping close to the boiler.
• Modern locations for a circulator is on the supply piping just beyond the air eliminator and the expansion tank.
• Early circulators were large and heavy. The easiest place to mount them was on the return piping close to the boiler.
• Modern locations for a circulator is on the supply piping just beyond the air eliminator and the expansion tank.
![Page 21: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/21.jpg)
21
Pump control panelsPump control panels
• Circulator pump panels (switching relays) control the operation of multiple pumps (zones) at one time.
– A thermostat located in the space to be heated calls for heat and the zone panel turns on the correct circulator for that space.
• Circulator pump panels (switching relays) control the operation of multiple pumps (zones) at one time.
– A thermostat located in the space to be heated calls for heat and the zone panel turns on the correct circulator for that space.
![Page 22: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/22.jpg)
22
Taco zoning controlsTaco zoning controls
![Page 23: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/23.jpg)
23
Zone valvesZone valves
• Zone valves are sometimes used to allow or dis-allow water from flowing through a system.
• Zone valves are either directly controlled by a thermostat or a zone panel
• Zone valves are sometimes used to allow or dis-allow water from flowing through a system.
• Zone valves are either directly controlled by a thermostat or a zone panel
![Page 24: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/24.jpg)
24
Zone valve brandsZone valve brands
• Taco Honeywell B & G• Taco Honeywell B & G
![Page 25: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/25.jpg)
25
Cut-away picture of a zone valveCut-away picture of a zone valve
![Page 26: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/26.jpg)
26
Zone valve panelsZone valve panels
• Zone valves can also be controlled by a panel much like the circulator pumps.
• Zone valves can also be controlled by a panel much like the circulator pumps.
![Page 27: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/27.jpg)
27Non-electrical componentsNon-electrical components
• Expansion Tanks
– There are two types of expansion tanks• Standard expansion tank
– Nothing more than a large tank located somewhere above the boiler.
• Diaphragm expansion tank–Divided into two sections separated by a
rubber, semi-permeable membrane.–One side of the tank contains air and the
other side is open to the water circuit.
• Expansion Tanks
– There are two types of expansion tanks• Standard expansion tank
– Nothing more than a large tank located somewhere above the boiler.
• Diaphragm expansion tank–Divided into two sections separated by a
rubber, semi-permeable membrane.–One side of the tank contains air and the
other side is open to the water circuit.
![Page 28: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/28.jpg)
28
Modern diaphragm expansion tank with air scoop
and vent.Modern diaphragm expansion tank with air scoop
and vent.
![Page 29: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/29.jpg)
29
Automatic water feedAutomatic water feed
• Automatically maintains the preset water pressure in the system.
• Usually 12-14 psi
• Automatically maintains the preset water pressure in the system.
• Usually 12-14 psi
![Page 30: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/30.jpg)
30
Combination Auto Feed and Backflow PreventerCombination Auto Feed and Backflow Preventer
The backflow preventer allows water flow only in one direction similar to a check valve.
Its very common to see the backflow preventer and the water feeder together like this.
The backflow preventer allows water flow only in one direction similar to a check valve.
Its very common to see the backflow preventer and the water feeder together like this.
![Page 31: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/31.jpg)
31
Pressure-reducing ValvePressure-reducing Valve
• Another name for the water feeder is the pressure reducing valve.
• The pressure-reducing valve automatically lowers the pressure of the supply water to the pressure at which the boiler is designed to maintain.
• Another name for the water feeder is the pressure reducing valve.
• The pressure-reducing valve automatically lowers the pressure of the supply water to the pressure at which the boiler is designed to maintain.
![Page 32: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/32.jpg)
32
Pressure reducing valvePressure reducing valve
![Page 33: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/33.jpg)
33Pressure Relief ValvePressure Relief Valve
• The pressure relief valve is designed to open if the pressure in the system reaches the set point on the valve.
– The is the most important safety device installed on a hydronic system.
• The pressure relief valve is designed to open if the pressure in the system reaches the set point on the valve.
– The is the most important safety device installed on a hydronic system.
![Page 34: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/34.jpg)
34Pressure Relief ValvePressure Relief Valve
![Page 35: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/35.jpg)
35Flow-Control ValveFlow-Control Valve
• The flow-control valve controls flow in a hydronic system.
• The flow control valve is also called a check valve or flow check.
• The flow-control valve controls flow in a hydronic system.
• The flow control valve is also called a check valve or flow check.
![Page 36: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/36.jpg)
36Flow-Control Valve typesFlow-Control Valve types
![Page 37: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/37.jpg)
37Balancing ValveBalancing Valve
• Balancing valves are used to even the water flow through each branch of the circuit.
• Balancing valves are installed in each branch of the circuit and are manually adjusted.
• Balancing valves are used to even the water flow through each branch of the circuit.
• Balancing valves are installed in each branch of the circuit and are manually adjusted.
![Page 38: 1 HVACR216 - Hydronics Hydronic Heating. 2 Hydronic Heating Systems Hydronic heating systems rely on circulating water or steam to deliver heat to the](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649e435503460f94b37204/html5/thumbnails/38.jpg)
38
Balancing ValveBalancing Valve