1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ......

8
PROJECT DATA PROJECT DESCRIPTION INDEX SITE LOCATION MAP SCALE: NTS G0.0 LS1.0 A1.0 A2.0 A3.0 A3.1 M-1 M-2 E-1 E-2 E-3 P-1 COVER SHEET LIFE SAFETY NOTES AND DETAILS FLOOR PLAN REFLECTED CEILING PLAN FRAMING NOTES AND TOILET DETAILS SECTIONS AND DETAILS HVAC PLAN HVAC DETAILS AND SCHEDULE GENERAL NOTES AND RISER DIAGRAM POWER FLOOR PLAN LIGHTING FLOOR PLAN PLUMBING PLAN AND NOTES REFERENCE PLAN SCALE: NTS AUTHORITIES P R O P E R T Y D A T A ADDRESS 3616 BOGAN RD. SUITE 210 BUFORD, GA 30519 ASCENT HOSPITALITY MANAGEMENT 715 COLLEGE DRIVE DALTON, GA 30720 (706) 529-6900 OWNER P R O J E C T D I R E C T O R Y ADC DEVELOPMENT GROUP 2611 PINE SPRINGS LN SE MARIETTA GA 30067 CONTACT: 404.274.0207 EMAIL: [email protected] BENNIE ESTILL SKAGGS GA REG. # RA010689 ARCHITECT TBA GENERAL CONTRACTOR BUILDING CODE COMPLIANCE CHECKLIST PROJECT CRITERIA : PLAN REVIEW IS BASED ON THE FOLLOWING INFORMATION: BUILDING PERMIT NO: PROJECT NAME: ASCENT HOSPITALITY MANAGEMENT OCCUPANCY CLASSIFICATION: BUSINESS CALCULATED OCCUPANT LOAD :47 PERSONS TYPE OF CONSTRUCTION: IIB SPRINKLERED (YES OR NO): YES BUILDING AREA PER FLOOR: SHELL: 10,400 SF TENANT FINISH TOTAL AREA: 3900 SF NEW BASEMENT AREA: N/A NEW MEZZANINE AREA: N/A NEW CANOPY-PORCH-BALCONY AREA: N/A SCOPE OF BLDG PERMIT ([X] AS APPLICABLE): [ # BUILDINGS: 1 ] [X] INTERIOR FINISH BUILDING PERMIT ONLY [ # SUITES / UNITS: SUITE # 210 ] REQUIRED MINIMUM LIVE LOADS (PSF): FLOOR: 100 ROOF : 20 APPLICABLE BUILDING CODES: THE SCOPE OF THIS PROJECT IS THE NEW CONSTRUCTION OF A 3900 S.F. INTERIOR FINISH OF AN EXISTING VACANT SHELL. - CITY OF BUFORD PLANNING & DEVELOPMENT - GWINNETT COUNTY FIRE MARSHAL 1. SIGNS SHALL BE PERMITTED SEPARATELY. CONTACT BUILDING PLAN REVIEW FOR ADDITIONAL INFORMATION. FOR GROUND SIGNS, SUBMIT COMPLETE STRUCTURAL AND ELECTRICAL DETAILS WHICH CLEARLY INDICATE CONSTRUCTION REQUIREMENTS. 2. MECHANICAL, ELECTRICAL, AND PLUMBING SUBCONTRACTORS SHALL SUBMIT AFFIDAVITS FOR EACH BUILDING PERMIT TO THE BUILDING PERMITS SECTION AT LEAST TWO (2) BUSINESS DAYS BEFORE REQUESTING INSPECTIONS. (OBTAIN AFFIDAVIT FORMS FROM BUILDING PERMITS SECTION.) 3. A SIGN CLEARLY STATING THAT SMOKING IS PROHIBITED SHALL BE CONSPICUOUSLY POSTED BY THE BUILDING OWNER, AGENT, OPERATOR, PERSON IN CHARGE OR PROPRIETOR AT EACH ENTRANCE OR IN A POSITION CLEARLY VISIBLE UPON ENTRY INTO THE BUILDING IN ACCORDANCE WITH GEORGIA SMOKE FREE AIR ACT OF 2005. ACCEPTABLE SIGNS SHALL DISPLAY EITHER "NO SMOKING" OR THE INTERNATIONAL "NO SMOKING" SYMBOL (CONSISTING OF A PICTORIAL REPRESENTATION OF A BURNING CIGARETTE ENCLOSED IN A RED CIRCLE WITH A RED BAR ACROSS IT). - GWINNETT COUNTY CLEAN INDOOR AIR ORDINANCE ( ARTICLE VI SECTION 42-129), RULES OF THE DEPARTMENT OF HUMAN RESOURCES PUBLIC SECTION 290-5-61-.05 & O.C.G.A. SECTON 31-12A-8. ACCESSIBILITY: - GEORGIA ACCESIBILITY CODE - GSFC RULES & REGS. 120-3-20 - LATEST REVISION. FIRE CODES: - 1995 GWINNETT COUNTY ORDINANCE FOR FIRE PROTECTION AND LIFE SAFETY - THE CURRENT EDITION OF THE NFPA CODES AND STANDARDS AS ADOPTED AND MODIFIED BY THE STATE FIRE MARSHAL - NFPA 101 LIFE SAFETY CODE 2000 EDITION - INTERNATIONAL FIRE CODE 2006 EDITION - OCGA TITLES 25 AND TITLE 30 GEORGIA ACCESSIBILITY CODE INTERNATIONAL BUILDING CODE (ICC): - 2006 EDITION WITH 2007, 2009, & 2010 GA STATE AMENDMENTS INTERNATIONAL MECHANICAL CODE (ICC): - 2006 EDITION WITH 2007, 2008, 2010, & 2011 GA STATE AMENDMENTS INTERNATIONAL PLUMBING CODE (ICC): - 2006 EDITION WITH, 2007, 2008, 2009, 2010, & 2011 GA STATE AMENDMENTS INTERNATIONAL FUEL GAS CODE (ICC): - 2006 EDITION WITH 2007 2008, 2009, & 2010 GA STATE AMENDMENTS NATIONAL ELECTRICAL CODE (NFPA): - 2008 EDITION WITH 2009 GA STATE AMENDMENTS INTERNATIONAL ENERGY CONSERVATION CODE (ICC): - 2009 EDITION WITH 2011 GA STATE SUPPLEMENTS AND AMENDMENTS INTERNATIONAL RESIDENTIAL CODE FOR ONE & TWO FAMILY DWELLINGS (ICC): - 2006 EDITION WITH 2007, 2008, 2009, 2010, & 2011 GA STATE AMENDMENTS LIFE SAFETY DIAGRAM 72 FT CODE DATA OCCUPANCY TYPE: BUSINESS CONSTRUCTION TYPE: SINGLE STORY - TYPE IIB - SPRINKLERED CONSTRUCTION PROTECTION A) FIRE PROTECTION OF STRUCTURAL ELEMENTS - IBC COMPLIANCE SECTION 602 B) COMBUSTIBLE MATERIALS - IBC COMPLIANCE SECTION 603 C) TENANT USE SEPARATION (1-HOUR) PARTITION OCCUPANCY LOAD: 39 PERSONS AREA OCC. CLASS SIZE (SF) SF/PERSON NO. PERSONS EGRESS CALCULATIONS FLOOR = 39 PERSONS x 0.2"/PERSON = 1 EXIT REQUIRED PER LSC, 2 EXITS PROVIDED OFFICE B 3900 100G 39 A B C D E A B C D E 1 2 3 4 5 6 1 2 3 4 5 6 The scale as stated, is valid only on original drawing. RELEASED FOR CONSTRUCTION CONTACT THE GWINNETT COUNTY FIRE MARSHAL'S (INSPECTION REQUEST LINE) AT 678-518-6102 FOR INSPECTIONS AT 50%, 80% AND 100% COMPLETION. INSPECTIONS WILL BE PERFORMED AS FOLLOWS: 50% COMPLETION: INSPECTION OF FLOOR CEILING PENETRATIONS. 80% COMPLETION: INSPECTION OF ANY FIRE RATED BARRIERS, FLOOR OR CEILING. 100% COMPLETION: ALL SYSTEMS, EQUIPMENT INSTALLED AND OPERATING, READY FOR OCCUPANCY THE INSPECTION REQUEST MUST BE PHONED IN BEFORE 2:00 P.M. THE DAY PRIOR TO THE DATE THE INSPECTION IS NEEDED. PERMIT CRITERIA FIRE AND SAFETY CRITERIA SEE LS1.0 SHEET FOR FIRE PROTECTION NOTES AND DETAILS

Upload: others

Post on 12-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

PROJECT DATA PROJECT DESCRIPTION INDEX

SITE LOCATION MAPSCALE: NTS

G0.0LS1.0A1.0A2.0A3.0A3.1M-1M-2E-1E-2E-3P-1

COVER SHEETLIFE SAFETY NOTES AND DETAILSFLOOR PLANREFLECTED CEILING PLANFRAMING NOTES AND TOILET DETAILSSECTIONS AND DETAILSHVAC PLANHVAC DETAILS AND SCHEDULEGENERAL NOTES AND RISER DIAGRAMPOWER FLOOR PLANLIGHTING FLOOR PLANPLUMBING PLAN AND NOTES

REFERENCE PLANSCALE: NTS

AUTHORITIESP R O P E R T Y D A T A

ADDRESS 3616 BOGAN RD. SUITE 210BUFORD, GA 30519

ASCENT HOSPITALITY MANAGEMENT715 COLLEGE DRIVEDALTON, GA 30720(706) 529-6900

OWNER

P R O J E C T D I R E C T O R Y

ADC DEVELOPMENT GROUP2611 PINE SPRINGS LN SEMARIETTA GA 30067CONTACT: 404.274.0207EMAIL: [email protected] ESTILL SKAGGSGA REG. # RA010689

ARCHITECT

TBAGENERAL CONTRACTOR

BUILDING CODE COMPLIANCE CHECKLISTPROJECT CRITERIA : PLAN REVIEW IS BASED ON THE FOLLOWING INFORMATION:

BUILDING PERMIT NO:PROJECT NAME: ASCENT HOSPITALITY MANAGEMENTOCCUPANCY CLASSIFICATION: BUSINESS CALCULATED OCCUPANT LOAD:47 PERSONSTYPE OF CONSTRUCTION: IIB SPRINKLERED (YES OR NO): YESBUILDING AREA PER FLOOR: SHELL: 10,400 SF TENANT FINISH TOTAL AREA: 3900 SFNEW BASEMENT AREA: N/A NEW MEZZANINE AREA: N/A NEW CANOPY-PORCH-BALCONYAREA: N/A

SCOPE OF BLDG PERMIT ([X] AS APPLICABLE):[ # BUILDINGS: 1 ] [X] INTERIOR FINISH BUILDING PERMIT ONLY[ # SUITES / UNITS: SUITE # 210 ] REQUIRED MINIMUM LIVE LOADS (PSF): FLOOR: 100ROOF : 20

APPLICABLE BUILDING CODES:

THE SCOPE OF THIS PROJECT IS THE NEW CONSTRUCTION OF A3900 S.F. INTERIOR FINISH OF AN EXISTING VACANT SHELL.- CITY OF BUFORD PLANNING & DEVELOPMENT

- GWINNETT COUNTY FIRE MARSHAL

1. SIGNS SHALL BE PERMITTED SEPARATELY. CONTACT BUILDINGPLAN REVIEW FOR ADDITIONAL INFORMATION. FOR GROUNDSIGNS, SUBMIT COMPLETE STRUCTURAL AND ELECTRICALDETAILS WHICH CLEARLY INDICATE CONSTRUCTIONREQUIREMENTS.

2. MECHANICAL, ELECTRICAL, AND PLUMBING SUBCONTRACTORSSHALL SUBMIT AFFIDAVITS FOR EACH BUILDING PERMIT TO THEBUILDING PERMITS SECTION AT LEAST TWO (2) BUSINESS DAYSBEFORE REQUESTING INSPECTIONS. (OBTAIN AFFIDAVIT FORMSFROM BUILDING PERMITS SECTION.)

3. A SIGN CLEARLY STATING THAT SMOKING IS PROHIBITED SHALLBE CONSPICUOUSLY POSTED BY THE BUILDING OWNER, AGENT,OPERATOR, PERSON IN CHARGE OR PROPRIETOR AT EACHENTRANCE OR IN A POSITION CLEARLY VISIBLE UPON ENTRYINTO THE BUILDING IN ACCORDANCE WITH GEORGIA SMOKEFREE AIR ACT OF 2005. ACCEPTABLE SIGNS SHALL DISPLAYEITHER "NO SMOKING" OR THE INTERNATIONAL "NO SMOKING"SYMBOL (CONSISTING OF A PICTORIAL REPRESENTATION OF ABURNING CIGARETTE ENCLOSED IN A RED CIRCLE WITH A REDBAR ACROSS IT). - GWINNETT COUNTY CLEAN INDOOR AIRORDINANCE ( ARTICLE VI SECTION 42-129), RULES OF THEDEPARTMENT OF HUMAN RESOURCES PUBLIC SECTION290-5-61-.05 & O.C.G.A. SECTON 31-12A-8.

ACCESSIBILITY:- GEORGIA ACCESIBILITY CODE - GSFC RULES & REGS. 120-3-20 - LATEST REVISION.

FIRE CODES:- 1995 GWINNETT COUNTY ORDINANCE FOR FIRE PROTECTION AND LIFE SAFETY- THE CURRENT EDITION OF THE NFPA CODES AND STANDARDS AS ADOPTED AND MODIFIED BY THE STATE FIRE MARSHAL- NFPA 101 LIFE SAFETY CODE 2000 EDITION- INTERNATIONAL FIRE CODE 2006 EDITION- OCGA TITLES 25 AND TITLE 30 GEORGIA ACCESSIBILITY CODE

INTERNATIONAL BUILDING CODE (ICC):- 2006 EDITION WITH 2007, 2009, & 2010 GA STATE AMENDMENTSINTERNATIONAL MECHANICAL CODE (ICC):- 2006 EDITION WITH 2007, 2008, 2010, & 2011 GA STATE AMENDMENTSINTERNATIONAL PLUMBING CODE (ICC):- 2006 EDITION WITH, 2007, 2008, 2009, 2010, & 2011 GA STATE AMENDMENTSINTERNATIONAL FUEL GAS CODE (ICC):- 2006 EDITION WITH 2007 2008, 2009, & 2010 GA STATE AMENDMENTSNATIONAL ELECTRICAL CODE (NFPA):- 2008 EDITION WITH 2009 GA STATE AMENDMENTSINTERNATIONAL ENERGY CONSERVATION CODE (ICC):- 2009 EDITION WITH 2011 GA STATE SUPPLEMENTS AND AMENDMENTSINTERNATIONAL RESIDENTIAL CODE FOR ONE & TWO FAMILY DWELLINGS (ICC):- 2006 EDITION WITH 2007, 2008, 2009, 2010, & 2011 GA STATE AMENDMENTS

LIFE SAFETY DIAGRAM

72 FT

CODE DATAOCCUPANCY TYPE: BUSINESS

CONSTRUCTION TYPE: SINGLE STORY - TYPE IIB - SPRINKLERED

CONSTRUCTION PROTECTIONA) FIRE PROTECTION OF STRUCTURAL ELEMENTS - IBC COMPLIANCE SECTION 602B) COMBUSTIBLE MATERIALS - IBC COMPLIANCE SECTION 603C) TENANT USE SEPARATION (1-HOUR) PARTITION

OCCUPANCY LOAD: 39 PERSONS

AREA OCC. CLASS SIZE (SF) SF/PERSON NO. PERSONS

EGRESS CALCULATIONS FLOOR = 39 PERSONS x 0.2"/PERSON = 1 EXIT REQUIRED PER LSC, 2 EXITS PROVIDED

OFFICE B 3900 100G 39

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

CONTACT THE GWINNETT COUNTY FIRE MARSHAL'S (INSPECTION REQUEST LINE) AT678-518-6102 FOR INSPECTIONS AT 50%, 80% AND 100% COMPLETION.INSPECTIONS WILL BE PERFORMED AS FOLLOWS:50% COMPLETION: INSPECTION OF FLOOR CEILING PENETRATIONS.80% COMPLETION: INSPECTION OF ANY FIRE RATED BARRIERS, FLOOR OR CEILING.100% COMPLETION: ALL SYSTEMS, EQUIPMENT INSTALLED AND OPERATING, READYFOR OCCUPANCYTHE INSPECTION REQUEST MUST BE PHONED IN BEFORE 2:00 P.M. THE DAY PRIORTO THE DATE THE INSPECTION IS NEEDED.

PERMIT CRITERIA

FIRE AND SAFETY CRITERIASEE LS1.0 SHEET FOR FIRE PROTECTION NOTES AND DETAILS

Page 2: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

1

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TIONFIRE EXTINGUISHER MOUNT HEIGHTS

SCALE: NTS

Page 3: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

Page 4: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

Page 5: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

Page 6: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

RISER DIAGRAM

PANEL SCHEDULE: A

SPECIFICATIONS:

SYMBOLS:

LIGHTING

WIRING DEVICES

S

S3

Sp

SM

SD

IG

GFCI

J

POWER

M

AFF

WP

E

SIGNAL

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

Page 7: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

GENERAL NOTES:

KEY NOTES

1

POWER FLOOR PLAN

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

J

WP

Page 8: 1 2 3 4 5 6 · a2.0 a3.0 a3.1 m-1 m-2 e-1 e-2 e-3 p-1 cover sheet life safety notes and details ... (consisting of a pictorial representation of a burning cigarette enclosed in a

GENERAL NOTES:

LIGHTING FIXTURE SCHEDULE

LIGHTING FLOOR PLAN

A

B

C

D

E

A

B

C

D

E

1 2 3 4 5 6

1 2 3 4 5 6The scale as stated, is valid only on original drawing.

RELE

ASE

D F

OR

CO

NST

RUC

TION

S

a

a

LIGHT FIXTURE DESIGNATION

SS

SS

SS

S

SS

S

S

a

S

a

a

a

a

S

3

b

bb

bb

S

3b

S

3

S

3c

S

3

S

3

c

c

c

c

c

c

c

d d

dd

d

S

S

S

S

3

e

e

e

e

S

3e

S

3

f

S

3

f

f

f

f

f

f f

f

f

f

f

f

g

S

3

g

S

3

g

g

g

g

g

g

g

g