096428r-itusp02v01 report-艾易 iologik e1210 -version...

59
No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com CERTIFICATE Issued Date: July 15, 2009 Report No.: 096428R-ITUSP02V01 This is to certify that the following designated product Product : Remote Ethernet I/O Server Trade name : Moxa Model Number : ioLogik E1210, ioLogik E1211, ioLogik E1212, ioLogik E1214, ioLogik E1240 Company Name : Moxa Inc. This product, which has been issued the test report listed as above in QuieTek Laboratory, is based on a single evaluation of one sample and confirmed to comply with the requirements of the following EMC standard. FCC CFR Title 47 Part 15 Subpart B: 2008 Class A, CISPR 22: 2005 ANSI C63.4: 2003 ICES-003 Issue 4: 2004 Class A TEST LABORATORY Vincent Lin / Manager

Upload: others

Post on 28-Oct-2019

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com

CERTIFICATE

Issued Date: July 15, 2009 Report No.: 096428R-ITUSP02V01

This is to certify that the following designated product

Product : Remote Ethernet I/O Server

Trade name : Moxa

Model Number : ioLogik E1210, ioLogik E1211, ioLogik E1212, ioLogik

E1214, ioLogik E1240

Company Name : Moxa Inc.

This product, which has been issued the test report listed as above in QuieTek

Laboratory, is based on a single evaluation of one sample and confirmed to

comply with the requirements of the following EMC standard.

FCC CFR Title 47 Part 15 Subpart B: 2008 Class A, CISPR 22: 2005

ANSI C63.4: 2003 ICES-003 Issue 4: 2004 Class A

TEST LABORATORY

Vincent Lin / Manager

Page 2: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Test Report Compliance with Industry Canada Interference-Causing

Equipment Standard ICES-003

Product Name : Remote Ethernet I/O Server

Model No. : ioLogik E1210, ioLogik E1211, ioLogik E1212,

ioLogik E1214, ioLogik E1240

Applicant : Moxa Inc.

Address : F1.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,

Taipei, Taiwan, R.O.C.

Date of Receipt : 2009/06/25

Issued Date : 2009/07/15

Report No. : 096428R-ITUSP02V01

Report Version : V1.0

The test results relate only to the samples tested.

The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein.

This report must not be used to claim product endorsement by TAF, NVLAP, NIST or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.

Page 3: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 2 of 58

Test Report Cert i f icat ion Issued Date : 2009/07/15 Report No. : 096428R-ITUSP02V01

Product Name : Remote Ethernet I/O Server

Applicant : Moxa Inc.

Address : F1.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,

Taipei, Taiwan, R.O.C.

Manufacturer : Moxa Inc.

Model No. : ioLogik E1210, ioLogik E1211, ioLogik E1212,

ioLogik E1214, ioLogik E1240

Rated Voltage : AC 120 V / 60 Hz

EUT Voltage : AC 100 - 240V / 50-60Hz

Trade Name : Moxa

Applicable Standard : FCC CFR Title 47 Part 15 Subpart B: 2008 Class A

CISPR 22: 2005 ANSI C63.4: 2003

ICES-003 Issue 4: 2004 Class A

Test Result : Complied

Performed Location : Quietek Corporation (Linkou Laboratory)

No.5-22,Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kuo

Shiang, Taipei, 244 Taiwan, R.O.C.

TEL:+866-2-8601-3788 / FAX:+886-2-8601-3789

Documented By :

( Senior Adm. Specialist / Genie Chang )

Reviewed By :

( Engineer / Elvis Su )

Approved By :

( Manager / Vincent Lin )

Page 4: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 3 of 58

Laboratory Information We , QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted (audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scopes:

The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://tw.quietek.com/modules/enterprise/services.php?item=100 The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory :

No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected]

LinKou Testing Laboratory :

No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]

Suzhou (China) Testing Laboratory :

No. 99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou,China.TEL : +86-512-6251-5088 / FAX : +86-512-6251-5098 E-Mail : [email protected]

Taiwan R.O.C. : BSMI, NCC, TAF

Germany : TUV Rheinland

Norway : Nemko, DNV

USA : FCC, NVLAP

Japan : VCCI

Page 5: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 4 of 58

TABLE OF CONTENTS Description Page 1. General Information .................................................................................................... 5

1.1. EUT Description................................................................................................... 5

1.2. Mode of Operation............................................................................................... 6

1.3. Tested System Details ......................................................................................... 7

1.4. Configuration of Tested System........................................................................... 8

1.5. EUT Exercise Software........................................................................................ 9

2. Technical Test ........................................................................................................... 10

2.1. Summary of Test Result..................................................................................... 10

2.2. List of Test Equipment ....................................................................................... 11

2.3. Measurement Uncertainty.................................................................................. 12

2.4. Test Environment ............................................................................................... 13

3. Conducted Emission................................................................................................. 14

3.1. Test Specification............................................................................................... 14

3.2. Test Setup.......................................................................................................... 14

3.3. Limit ................................................................................................................... 14

3.4. Test Procedure .................................................................................................. 15

3.5. Test Result ......................................................................................................... 16

3.6. Test Photograph ................................................................................................ 34

4. Radiated Emission.................................................................................................... 37

4.1. Test Specification............................................................................................... 37

4.2. Test Setup.......................................................................................................... 37

4.3. Limit ................................................................................................................... 38

4.4. Test Procedure .................................................................................................. 39

4.5. Test Result ......................................................................................................... 40

4.6. Test Photograph ................................................................................................ 46

5. Attachment................................................................................................................ 49

  EUT Photograph ................................................................................................ 49

Page 6: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 5 of 58

1. General Information

1.1. EUT Description

Product Name Remote Ethernet I/O Server

Trade Name Moxa

Model No. ioLogik E1210, ioLogik E1211, ioLogik E1212, ioLogik E1214,

ioLogik E1240

Component

Power Adapter

(Optional)

MFR: ENG, M/N: 3A-302DA20

Input: AC 100-240V, 50-60Hz, 0.8A

Output: DC 21-24V, 1.4-1.25A max 30W

Cable Out: Non-Shielded, 1.8m

Power Cord: Non-Shielded, 1.8m

Note:

The EUT is including five models and the different of each model is shown as below:

Model Name Description PCB

ioLogik E1210 16 Channel Digital Input E1210_V12

ioLogik E1211 16 Channel Digital Output E1210_V12

ioLogik E1212 8 Channel Digital Input /

8 Channel Digital Input/Output E1210_V12

ioLogik E1214 6 Channel Digital Input /

6 Channel Power Relay Output E1214_V12

ioLogik E1240 8 Channel Analog Input E1240_V12

Page 7: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 6 of 58

1.2. Mode of Operation QuieTek has verified the construction and function in typical operation. All the test modes were

carried out with the EUT in normal operation, which was shown in this test report and defined as:

Pre-Test Mode

Mode 1: Normal Operation (ioLogik E1210)

Mode 2: Normal Operation (ioLogik E1211)

Mode 3: Normal Operation (ioLogik E1212)

Mode 4: Normal Operation (ioLogik E1214)

Mode 5: Normal Operation (ioLogik E1240)

Final Test Mode

Emission

Mode 3: Normal Operation (ioLogik E1212)

Mode 4: Normal Operation (ioLogik E1214)

Mode 5: Normal Operation (ioLogik E1240)

Page 8: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 7 of 58

1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including

inserted cards) are:

Mode 3

Product Manufacturer Model No. Serial No. Power Cord

1 Test Board Moxa IoLogik E1212 N/A Non-Shielded, 0.8m

Mode 4

Product Manufacturer Model No. Serial No. Power Cord

1 Test Board Moxa IoLogik E1214 N/A Non-Shielded, 0.8m

Mode 5

Product Manufacturer Model No. Serial No. Power Cord

1 Test Board Moxa IoLogik E1240 N/A Non-Shielded, 0.8m

Page 9: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 8 of 58

1.4. Configuration of Tested System

Mode 3, Mode 4 and Mode 5

Connection Diagram

Signal Cable Type Signal cable Description

A Signal Cable Shielded, 0.15m

Page 10: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 9 of 58

1.5. EUT Exercise Software

1 Setup the EUT and simulators as shown on 1.4.

2 Turn on the power of all equipment.

3 A mufti meter was used to verify the model operation before the measurement.

Page 11: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 10 of 58

2. Technical Test

2.1. Summary of Test Result

No deviations from the test standards

Deviations from the test standards as below description:

Emission

Performed Item Normative References Test

Performed Deviation

Conducted Emission FCC CFR Title 47 Part 15 Subpart B: 2008 Class A

ANSI C63.4: 2003

Yes No

Radiated Emission FCC CFR Title 47 Part 15 Subpart B: 2008 Class A

ANSI C63.4: 2003

Yes No

Page 12: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 11 of 58

2.2. List of Test Equipment Conducted Emission / SR1 Instrument Manufacturer Type No. Serial No Cal. Date EMI Test Receiver R&S ESCS 30 100366 2008/10/20 LISN R&S ENV4200 833209/007 2008/08/14 LISN R&S ENV216 100085 2009/02/17 Pulse Limiter R&S ESH3-Z2 357.88.10.52 2008/09/09

Radiated Emission / Site3 Instrument Manufacturer Type No. Serial No Cal. Date Bilog Antenna Schaffner Chase CBL6112B 2704 2008/08/04 Broadband Horn Antenna Schwarzbeck BBHA9170 208 2008/07/30 EMI Test Receiver R&S ESCS 30 838251/001 2009/04/15 Horn Antenna Schwarzbeck BBHA9120D 305 2008/08/13 Pre-Amplifier QTK N/A N/A 2009/01/03 Spectrum Analyzer Advantest R3162 100803470 2008/11/25 EMI Test Receiver R&S ESI 26 838786/004 2008/07/22

Pre-Amplifier MITEQ QMF-4D-180400-45-6P

925974 2009/01/03

Page 13: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 12 of 58

2.3. Measurement Uncertainty Conducted Emission

The measurement uncertainty is evaluated as ± 2.26 dB.

Radiated Emission

The measurement uncertainty is evaluated as ± 3.19 dB.

Page 14: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 13 of 58

2.4. Test Environment

Performed Item Items Required Actual

Temperature (C) 15-35 25

Conducted Emission Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Temperature (C) 15-35 25

Radiated Emission Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Page 15: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 14 of 58

3. Conducted Emission

3.1. Test Specification

According to Standard : FCC Part 15 Subpart B, ANSI C63.4

3.2. Test Setup

3.3. Limit

Limits

Frequency (MHz)

QP (dBuV)

AV (dBuV)

0.15 - 0.50 79 66

0.50-5.0 73 60

5.0 - 30 73 60

Remarks: In the above table, the tighter limit applies at the band edges.

Page 16: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 15 of 58

3.4. Test Procedure

The EUT and simulators are connected to the main power through a line impedance

stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for

the measuring equipment. The peripheral devices are also connected to the main

power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm

termination. (Please refers to the block diagram of the test setup and photographs.)

Both sides of A.C. line are checked for maximum conducted interference. In order to

find the maximum emission, the relative positions of equipment and all of the

interface cables must be changed on conducted measurement.

Conducted emissions were invested over the frequency range from 0.15MHz to

30MHz using a receiver bandwidth of 9kHz.

Page 17: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 16 of 58

3.5. Test Result Site : SR1 Time : 2009/07/03 - 22:25

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 3

Page 18: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 17 of 58

Site : SR1 Time : 2009/07/03 - 22:25

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.193 9.821 36.780 46.601 -32.399 79.000 QUASIPEAK

2 0.318 9.830 33.890 43.720 -35.280 79.000 QUASIPEAK

3 0.884 9.830 18.500 28.330 -44.670 73.000 QUASIPEAK

4 1.392 9.840 18.930 28.770 -44.230 73.000 QUASIPEAK

5 8.740 9.910 19.920 29.830 -43.170 73.000 QUASIPEAK

6 14.822 10.200 14.810 25.010 -47.990 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 19: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 18 of 58

Site : SR1 Time : 2009/07/03 - 22:25

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.193 9.821 33.250 43.071 -22.929 66.000 AVERAGE

2 0.318 9.830 31.360 41.190 -24.810 66.000 AVERAGE

3 0.884 9.830 15.070 24.900 -35.100 60.000 AVERAGE

4 1.392 9.840 14.450 24.290 -35.710 60.000 AVERAGE

5 8.740 9.910 16.470 26.380 -33.620 60.000 AVERAGE

6 14.822 10.200 11.280 21.480 -38.520 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 20: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 19 of 58

Site : SR1 Time : 2009/07/03 - 22:25

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 3

Page 21: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 20 of 58

Site : SR1 Time : 2009/07/03 - 22:26

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.197 9.860 27.690 37.550 -41.450 79.000 QUASIPEAK

2 * 0.322 9.850 28.590 38.440 -40.560 79.000 QUASIPEAK

3 0.759 9.830 19.100 28.930 -44.070 73.000 QUASIPEAK

4 1.334 9.840 15.840 25.680 -47.320 73.000 QUASIPEAK

5 2.724 9.850 14.970 24.820 -48.180 73.000 QUASIPEAK

6 8.236 9.910 22.330 32.240 -40.760 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 22: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 21 of 58

Site : SR1 Time : 2009/07/03 - 22:26

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.197 9.860 15.630 25.490 -40.510 66.000 AVERAGE

2 0.322 9.850 21.980 31.830 -34.170 66.000 AVERAGE

3 0.759 9.830 17.160 26.990 -33.010 60.000 AVERAGE

4 1.334 9.840 13.770 23.610 -36.390 60.000 AVERAGE

5 2.724 9.850 14.870 24.720 -35.280 60.000 AVERAGE

6 * 8.236 9.910 22.150 32.060 -27.940 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 23: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 22 of 58

Site : SR1 Time : 2009/07/03 - 22:36

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 4

Page 24: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 23 of 58

Site : SR1 Time : 2009/07/03 - 22:36

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.189 9.820 38.380 48.200 -30.800 79.000 QUASIPEAK

2 0.318 9.830 31.990 41.820 -37.180 79.000 QUASIPEAK

3 0.505 9.820 24.620 34.440 -38.560 73.000 QUASIPEAK

4 2.119 9.850 20.140 29.990 -43.010 73.000 QUASIPEAK

5 7.923 9.900 32.000 41.900 -31.100 73.000 QUASIPEAK

6 18.244 10.200 30.730 40.930 -32.070 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 25: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 24 of 58

Site : SR1 Time : 2009/07/03 - 22:36

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.189 9.820 33.250 43.070 -22.930 66.000 AVERAGE

2 0.318 9.830 26.050 35.880 -30.120 66.000 AVERAGE

3 0.505 9.820 20.860 30.680 -29.320 60.000 AVERAGE

4 2.119 9.850 17.510 27.360 -32.640 60.000 AVERAGE

5 * 7.923 9.900 31.770 41.670 -18.330 60.000 AVERAGE

6 18.244 10.200 29.780 39.980 -20.020 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 26: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 25 of 58

Site : SR1 Time : 2009/07/03 - 22:37

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 4

Page 27: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 26 of 58

Site : SR1 Time : 2009/07/03 - 22:38

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.197 9.860 28.030 37.890 -41.110 79.000 QUASIPEAK

2 0.322 9.850 25.810 35.660 -43.340 79.000 QUASIPEAK

3 * 0.505 9.830 23.540 33.370 -39.630 73.000 QUASIPEAK

4 1.013 9.830 21.860 31.690 -41.310 73.000 QUASIPEAK

5 9.379 9.920 19.090 29.010 -43.990 73.000 QUASIPEAK

6 12.796 10.120 16.970 27.090 -45.910 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 28: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 27 of 58

Site : SR1 Time : 2009/07/03 - 22:38

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.197 9.860 22.580 32.440 -33.560 66.000 AVERAGE

2 0.322 9.850 17.850 27.700 -38.300 66.000 AVERAGE

3 * 0.505 9.830 20.050 29.880 -30.120 60.000 AVERAGE

4 1.013 9.830 18.750 28.580 -31.420 60.000 AVERAGE

5 9.379 9.920 12.990 22.910 -37.090 60.000 AVERAGE

6 12.796 10.120 14.620 24.740 -35.260 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 29: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 28 of 58

Site : SR1 Time : 2009/07/03 - 22:48

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 5

Page 30: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 29 of 58

Site : SR1 Time : 2009/07/03 - 22:48

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.193 9.821 35.910 45.731 -33.269 79.000 QUASIPEAK

2 0.318 9.830 33.290 43.120 -35.880 79.000 QUASIPEAK

3 0.951 9.830 22.400 32.230 -40.770 73.000 QUASIPEAK

4 2.091 9.850 18.590 28.440 -44.560 73.000 QUASIPEAK

5 8.365 9.900 25.640 35.540 -37.460 73.000 QUASIPEAK

6 * 25.002 10.240 37.000 47.240 -25.760 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 31: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 30 of 58

Site : SR1 Time : 2009/07/03 - 22:48

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-L1 - Line1

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.193 9.821 31.400 41.221 -24.779 66.000 AVERAGE

2 0.318 9.830 32.010 41.840 -24.160 66.000 AVERAGE

3 0.951 9.830 22.390 32.220 -27.780 60.000 AVERAGE

4 2.091 9.850 18.580 28.430 -31.570 60.000 AVERAGE

5 8.365 9.900 25.630 35.530 -24.470 60.000 AVERAGE

6 * 25.002 10.240 36.250 46.490 -13.510 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 32: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 31 of 58

Site : SR1 Time : 2009/07/03 - 22:49

Limit : CISPR_A_00M_QP Margin : 10

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 5

Page 33: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 32 of 58

Site : SR1 Time : 2009/07/03 - 22:49

Limit : CISPR_A_00M_QP Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.189 9.860 38.260 48.120 -30.880 79.000 QUASIPEAK

2 0.314 9.850 32.000 41.850 -37.150 79.000 QUASIPEAK

3 0.505 9.830 23.530 33.360 -39.640 73.000 QUASIPEAK

4 1.330 9.840 21.040 30.880 -42.120 73.000 QUASIPEAK

5 8.427 9.910 24.690 34.600 -38.400 73.000 QUASIPEAK

6 * 24.998 10.290 36.360 46.650 -26.350 73.000 QUASIPEAK

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 34: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 33 of 58

Site : SR1 Time : 2009/07/03 - 22:49

Limit : CISPR_A_00M_AV Margin : 0

EUT : Remote Ethernet I/O Server Probe : ENV-216-N - Line2

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.189 9.860 28.060 37.920 -28.080 66.000 AVERAGE

2 0.314 9.850 27.050 36.900 -29.100 66.000 AVERAGE

3 0.505 9.830 23.520 33.350 -26.650 60.000 AVERAGE

4 1.330 9.840 21.030 30.870 -29.130 60.000 AVERAGE

5 8.427 9.910 24.680 34.590 -25.410 60.000 AVERAGE

6 * 24.998 10.290 36.250 46.540 -13.460 60.000 AVERAGE

Note:

1. All Reading Levels are Quasi-Peak and average value.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 35: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 34 of 58

3.6. Test Photograph Test Mode : Mode 3: Normal Operation (ioLogik E1212)

Description : Front View of Conducted Test

Test Mode : Mode 3: Normal Operation (ioLogik E1212)

Description : Back View of Conducted Test

Page 36: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 35 of 58

Test Mode : Mode 4: Normal Operation (ioLogik E1214)

Description : Front View of Conducted Test

Test Mode : Mode 4: Normal Operation (ioLogik E1214)

Description : Back View of Conducted Test

Page 37: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 36 of 58

Test Mode : Mode 5: Normal Operation (ioLogik E1240)

Description : Front View of Conducted Test

Test Mode : Mode 5: Normal Operation (ioLogik E1240)

Description : Back View of Conducted Test

Page 38: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 37 of 58

4. Radiated Emission

4.1. Test Specification

According to EMC Standard : FCC Part 15 Subpart B, ANSI C63.4

4.2. Test Setup

Under 1GHz Test Setup:

Above 1GHz Test Setup:

Page 39: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 38 of 58

4.3. Limit

Under 1GHz test shall not exceed the following value:

Limits

Frequency (MHz)

Distance (m) dBuV/m

30 – 230 10 40

230 – 1000 10 47

Remark:

1. The tighter limit shall apply at the edge between two frequency bands.

2. Distance refers to the distance in meters between the measuring instrument antenna and

the closed point of any part of the device or system.

Above 1GHz test shall not exceed the following value:

FCC Part 15 Subpart B Paragraph 15.109 Limits (dBuV/m)

Frequency

(MHz) Distance(m) dBuV/m

30-88 10 39

88-216 10 43.5

216-960 10 46.4

Above 960 10 49.5

Remark:

1. The tighter limit shall apply at the edge between two frequency bands.

2. Distance refers to the distance in meters between the measuring instrument

antenna and the closed point of any part of the device or system.

3. RF Voltage (dBuV/m) = 20 log RF Voltage (uV/m)

Page 40: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 39 of 58

4.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.

The turn table can rotate 360 degrees to determine the position of the maximum emission level and the antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level.

Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated on radiated measurement.

For an unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest radio frequency signal generated or used in the device, without going below the lowest frequency for which a radiated emission limit is specified, up to the frequency shown in the folowing table:

Highest frequency generated or used in the device or on which the

device operates or tunes (MHz)

Upper frequency of measurement range (MHz)

Below 1.705 30

1.705 – 108 1000

108 – 500 2000

500 – 1000 5000

Above 1000 5th harmonic of the highest

frequency or 40 GHz, whichever is lower

On any frequency or frequencies below or equal to 1000 MHz, the radiated limits shown are based on measuring equipment employing a quasi-peak detector function and above 1000 MHz, the radiated limits shown are based measuring equipment employing an average detector function. When average radiated emission measurement are included emission measurement Above 1000 MHz, there also is a limit on the radio frequency emissions, as measured using instrumentation with a peak detector function, corresponding to 20 dB above the maximum permitted average limit. For class A, the measurement distance between the EUT and antenna is 10 meters for under 1GHz and above 1GHz. For class B, the measurement distance between the EUT and antenna is 10 meters for under 1GHz and 3 meters for above 1GHz.

The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS

30) is 120 kHz and above 1GHz is 1MHz.

Page 41: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 40 of 58

4.5. Test Result Site : OATS-3 Time : 2009/07/04 - 00:15

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - HORIZONTAL

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 125.000 15.012 8.200 23.212 -16.788 40.000 QUASIPEAK

2 174.350 12.637 6.400 19.037 -20.963 40.000 QUASIPEAK

3 300.000 17.401 14.400 31.801 -15.199 47.000 QUASIPEAK

4 375.000 19.410 14.200 33.610 -13.390 47.000 QUASIPEAK

5 * 450.000 21.080 14.200 35.280 -11.720 47.000 QUASIPEAK

6 525.000 22.493 10.400 32.893 -14.107 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 42: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 41 of 58

Site : OATS-3 Time : 2009/07/03 - 23:58

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - VERTICAL

Power : AC 120V/60Hz Note : Mode 3

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 51.216 10.430 14.800 25.230 -14.770 40.000 QUASIPEAK

2 * 125.001 15.012 17.800 32.812 -7.188 40.000 QUASIPEAK

3 175.900 12.579 9.400 21.979 -18.021 40.000 QUASIPEAK

4 300.000 17.401 15.400 32.801 -14.199 47.000 QUASIPEAK

5 375.002 19.410 14.500 33.910 -13.090 47.000 QUASIPEAK

6 450.002 21.080 11.000 32.080 -14.920 47.000 QUASIPEAK

7 525.000 22.493 6.400 28.893 -18.107 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 43: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 42 of 58

Site : OATS-3 Time : 2009/07/04 - 00:47

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - HORIZONTAL

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 125.000 15.012 8.900 23.912 -16.088 40.000 QUASIPEAK

2 300.001 17.401 11.600 29.001 -17.999 47.000 QUASIPEAK

3 375.003 19.410 14.600 34.010 -12.990 47.000 QUASIPEAK

4 400.000 20.079 11.800 31.879 -15.121 47.000 QUASIPEAK

5 * 450.000 21.080 17.400 38.480 -8.520 47.000 QUASIPEAK

6 525.005 22.493 9.800 32.293 -14.707 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 44: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 43 of 58

Site : OATS-3 Time : 2009/07/04 - 00:32

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - VERTICAL

Power : AC 120V/60Hz Note : Mode 4

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 50.985 10.503 14.300 24.803 -15.197 40.000 QUASIPEAK

2 * 125.000 15.012 14.500 29.512 -10.488 40.000 QUASIPEAK

3 179.050 12.451 6.800 19.250 -20.750 40.000 QUASIPEAK

4 300.002 17.401 12.400 29.801 -17.199 47.000 QUASIPEAK

5 375.000 19.410 14.800 34.210 -12.790 47.000 QUASIPEAK

6 450.003 21.080 8.800 29.880 -17.120 47.000 QUASIPEAK

7 525.007 22.493 8.400 30.893 -16.107 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 45: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 44 of 58

Site : OATS-3 Time : 2009/07/03 - 23:40

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - HORIZONTAL

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 125.000 15.012 11.400 26.412 -13.588 40.000 QUASIPEAK

2 300.000 17.401 11.500 28.901 -18.099 47.000 QUASIPEAK

3 * 450.000 21.080 15.800 36.880 -10.120 47.000 QUASIPEAK

4 525.000 22.493 12.400 34.893 -12.107 47.000 QUASIPEAK

5 675.009 24.610 6.400 31.009 -15.991 47.000 QUASIPEAK

6 825.012 26.656 4.500 31.156 -15.844 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 46: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 45 of 58

Site : OATS-3 Time : 2009/07/03 - 23:23

Limit : CISPR_A_10M_QP Margin : 6

EUT : Remote Ethernet I/O Server Probe : Site3_CBL6112_10M_0811 - VERTICAL

Power : AC 120V/60Hz Note : Mode 5

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 * 125.000 15.012 15.900 30.912 -9.088 40.000 QUASIPEAK

2 179.900 12.429 8.700 21.129 -18.871 40.000 QUASIPEAK

3 225.000 14.512 15.100 29.612 -10.388 40.000 QUASIPEAK

4 300.000 17.401 14.200 31.601 -15.399 47.000 QUASIPEAK

5 450.005 21.080 10.100 31.180 -15.820 47.000 QUASIPEAK

6 525.000 22.493 11.400 33.893 -13.107 47.000 QUASIPEAK

7 750.012 25.603 6.100 31.703 -15.297 47.000 QUASIPEAK

Note:

1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or

average measurements as necessary.

2. " * ", means this data is the worst emission level.

3. Measurement Level = Reading Level + Correct Factor

Page 47: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 46 of 58

4.6. Test Photograph Test Mode : Mode 3: Normal Operation (ioLogik E1212)

Description : Front View of Radiated Test

Test Mode : Mode 3: Normal Operation (ioLogik E1212)

Description : Back View of Radiated Test

Page 48: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 47 of 58

Test Mode : Mode 4: Normal Operation (ioLogik E1214)

Description : Front View of Radiated Test

Test Mode : Mode 4: Normal Operation (ioLogik E1214)

Description : Back View of Radiated Test

Page 49: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 48 of 58

Test Mode : Mode 5: Normal Operation (ioLogik E1240)

Description : Front View of Radiated Test

Test Mode : Mode 5: Normal Operation (ioLogik E1240)

Description : Back View of Radiated Test

Page 50: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 49 of 58

5. Attachment EUT Photograph

(1) EUT Photo (M/N: ioLogik E1210)

(2) EUT Photo (M/N: ioLogik E1210)

Page 51: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 50 of 58

(3) EUT Photo (M/N: ioLogik E1210)

(4) EUT Photo (M/N: ioLogik E1210)

Page 52: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 51 of 58

(5) EUT Photo (M/N: ioLogik E1211)

(6) EUT Photo (M/N: ioLogik E1211)

Page 53: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 52 of 58

(7) EUT Photo (M/N: ioLogik E1211)

(8) EUT Photo (M/N: ioLogik E1211)

Page 54: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 53 of 58

(9) EUT Photo (M/N: ioLogik E1212)

(10) EUT Photo (M/N: ioLogik E1212)

Page 55: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 54 of 58

(11) EUT Photo (M/N: ioLogik E1212)

(12) EUT Photo (M/N: ioLogik E1212)

Page 56: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 55 of 58

(13) EUT Photo (M/N: ioLogik E1214)

(14) EUT Photo (M/N: ioLogik E1214)

Page 57: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 56 of 58

(15) EUT Photo (M/N: ioLogik E1214)

(16) EUT Photo (M/N: ioLogik E1214)

Page 58: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 57 of 58

(17) EUT Photo (M/N: ioLogik E1240)

(18) EUT Photo (M/N: ioLogik E1240)

Page 59: 096428R-ITUSP02V01 Report-艾易 ioLogik E1210 -Version V1…support.elmark.com.pl/moxa/products/Moduly_ioLogik/ioLogik-E1200... · EUT Exercise Software 1 Setup the EUT and simulators

Report No: 096428R-ITUSP02V01

Page: 58 of 58

(19) EUT Photo (M/N: ioLogik E1240)

(20) EUT Photo (M/N: ioLogik E1240)