07A – Multi-Tank Calibration
Apollo System 7A-1
1. Divert hydraulic Flow from Fan
2. Adjust product diverters to Calibration setting
3. Insert the Calibration deflector.
4. Slide sample collection tray onto collector.
5. Adjust the transmissions by moving the locking pin from Direct Drive to Slow Speed Drive.
(DIRECT DRIVE SHOWN) ENSURE THE TRACTOR IS NOT RUNNING WHILE REMOVING PINS!
-
07A – Multi-Tank Calibration
7A-2 Apollo System
6. Press the Topcon logo for one second to load the Global Home screen menu.
7. Navigate to the Calibration page.
TAP QUICKLY TO
LOAD SCREENS
-
07A – Multi-Tank Calibration
Apollo System 7A-3
8. Follow the above step in sequence.
1. ENABLE MANUAL
SPEED (GREEN)
2. SET YOUR DESIRED
SPEED
3. Use Arrows to Select
Tank to be calibrated.
4. SELECT GEAR RATIO:
2 (DIRECT) or 16 (SLOW)
5. Press Multi-Tank
Calibration to Start the
Wizard.
-
07A – Multi-Tank Calibration
7A-4 Apollo System
9. Select Automatic Calibration.
10. Follow the Prompt on the Calibration Wizard. Press the Yellow forward arrow.
-
07A – Multi-Tank Calibration
Apollo System 7A-5
11. Check the target rates are set correctly.
12. Turn on the Tanks you wish to calibrate by using the Number 1-2-3-4 on the Keypad. The color will
change From Red (Off) to Orange (Ready State).
-
07A – Multi-Tank Calibration
7A-6 Apollo System
13. Activate the metering by pressing the RUN/STOP button. The metering will then engage and
distribute the product into the sample collector trays.
14. The Estimated Weight will count continuously as product is collected into the Sample Collector.
Keep an eye on the collector boxes, fill until roughly ¾ full.
Keep all hands and personal
clear from the metering
systems, remember multiple
tanks are now live and are
ready to engage.
-
07A – Multi-Tank Calibration
Apollo System 7A-7
15. When the sample trays are nearly Full Press the Number keys 1-2-3-4 to stop the Tanks from
metering any additional product. When All Tanks are finished Press the RUN/STOP button.
NOTE: You may stop any tank early by simply pressing the Number Key.
Notice how the Tank LED status is RED = OFF
16. Remove the Collector Trays and Weigh the Product using the provided scale.
22.70 lbs.
-
07A – Multi-Tank Calibration
7A-8 Apollo System
17. Write down Tank scale weights and return to the tractor cab.
18. Return to the monitor, Press Next to Proceed.
-
07A – Multi-Tank Calibration
Apollo System 7A-9
19. Notice the estimated weights. Now Enter the Actual recorded weight in the weight windows.
20. Proceed by pressing the Next icon.
Press here to enter the
weights from the scale
-
07A – Multi-Tank Calibration
7A-10 Apollo System
21. Press the Green Saved Icon and then the Green Accept Check mark to save the Calibration factor.
22. It is recommends to repeat the Calibration procedure 2-3 additional times to fine tune and verify
the calibration factors are accurate.
Confirm the Cal factor by
pressing the Accept Icon.
-
07A – Multi-Tank Calibration
Apollo System 7A-11
NOTES: