04 aplicación palpador ballena

5
Special inspection problems solved by matched ultrasonic probe design Roye, W. and Schlengermann, U. Krautkrämer GmbH & Co., Hürth, Germany

Upload: carlos-fredy-echeverria

Post on 15-Dec-2015

218 views

Category:

Documents


3 download

DESCRIPTION

aplicador palpador ballena

TRANSCRIPT

Page 1: 04 Aplicación Palpador Ballena

Special inspection problems

solved by

matched ultrasonic probe design

Roye, W. and Schlengermann, U.

Krautkrämer GmbH & Co., Hürth, Germany

Page 2: 04 Aplicación Palpador Ballena

Inspection of turbine blades

Requirements:

- detection of cracks in the root

- reliable

- fast

- “on the wings” crack

Page 3: 04 Aplicación Palpador Ballena

The “Whale Probe”

crack

“Whale probe”

Transducer

corner

Page 4: 04 Aplicación Palpador Ballena

A-Scans of the whale probe

Crack Echo

Corner Echo

with crack echowithout flaw

Page 5: 04 Aplicación Palpador Ballena

The “Whale Probe”