01a. berm type 1. plan, scale 1:50 01b. berm type 1. front, scale … · 2018-01-23 · -all...

1
Me Me Me Me Me Me Me Me 8000 5000 1833 5000 37° 37° 1200 1833 77° 77° 126 10 44 143° 143° 103° 103° 6925 6925 6741 8000 8000 5000 1833 5000 37° 37° 1200 1833 77° 77° 126 10 44 143° 143° 103° 103° 6925 6925 6741 8000 8000 5000 1833 77° 77° 126 10 44 103° 103° 8000 2836 1594 Mild steel frame painted grey. Grass turf face. Gabion face. Gabion face. Gabion face. Gabion face. Grass turf face. Gabion face. Gabion face. Grass turf face. Gabion face. Gabion face. Gabion face. Grass turf face. Mild steel frame painted grey. Mild steel frame painted grey. Mild steel frame painted grey. Mild steel frame painted grey. Ground Level. 200mm Topsoil. 350mm Subsoil. 400mm Hardcore (Min). Ground Level. Tree Pit Detail See Dwg 1516-104-LA-T004 200mm Topsoil. 350mm Subsoil. 400mm Hardcore (Min). Grass turf face. Grass turf face. Grass turf face. Grass turf face. Notes: -Berm constructed with hardcore to base/core laid in 200mm consolidated layers with 350mm subsoil, turfed faces to be topped with 200mm good quality topsoil (to BS 3882). See Detail 01d & 02d -Welded mesh/Stone facing to berms to be constructed using Galfan coated welded mesh, wire diameter 3mm, mesh spacing 50mm x 50mm, to be secured with galvanized gabion clips. Faces to be 100mm deep, length and width to vary with face as shown. Gabions to be filled with 50-70mm dark grey, clean cut stone, from local source to be approved by LA. -Grass faces to Berms to be turfed using 19mm deep 'standard' lawn turf supplied by KMC lawn turf or similar and approved. -Berm frame constructed using mild steel beams, 100mm wide x 6mm deep x length to vary as shown. All welds and fittings to be internal. Frame to be finished using Epigrip C400 Epoxy Phosphate Primer/Buildcoat and Martime grade paint such as Leighs EPIGRIP K267HS (RAL7023 Concrete Grey) or similar and approved. -Frame to sit evenly on top of grass and gabion faces with frame secured to concrete base using steel lugs and bolt fittings, to enginneers specification, frame to sit flush with ground level. -Concrete parameter stripe foundation for berm to lenght and width of berm frame, 150mm deep with 150mm hardcore base layer, see engineers drawing 4119 -221. -Concrete bands to be 500mm wide, 150mm deep with 150mm hardcore base layer, to engineers specification. Concrete to be poured at the later stages of construction to avoid damage by construction traffic. -All steel fabrication and erection to be carried out in accordance with the National Structural Steelwork Specification for Building Construction. -All steel to be fabricated, supplied & erected in accordance with BS449 & BS5950. -All connections, welding, etc to be in accordance with the relevant British Standard Code of Practice. -A minimum of 14 working days before fabrication, a complete set of detailed fabrication & / or erection drawings and calculations shall be submitted to the LA for approval. -Fabricator to ensure that all edges have a 2-3mm radius and welds are ground down to prevent any sharp edges. -The steel fabricator shall ensure that all steel components have suitable lifting points for erection and that craneage is adequate and provide any necessary temporary bracing required for erection purposes. -No welding to be carried out on site unless agreed in advance with the National Roads Authority and subject to safety measures being agreed. -All steelwork to be Blast Cleaned to Sa 2.5 of BS 7079: part A1 : 1989. Surface profile to be within the range 30-75 microns typical. -Drawing to be read in conjunction with: Documents: 1516-Specification, 1516-Preliminaries, 1516-104-SOW Landscape Drawings: 1516-104-LA-T001 Site Location Plan, 1516-104-LA-T002 Landscape Layout, 1516-104-LA-T003 Berm details, 1516-104-LA-T004 Planting plan and details. Engineers Drawings: 4119-221 Berm Details -Any discrepancies regarding measurements, finishes and levels are to be highlighted by contractor prior to commencement on site. -Measurements on drawings are indicative, contractor to check all measurements prior to fabrication to provide information in relation to berm and frames -Any errors or contradictions between drawings/specification/schedule of works to be highlighted by contractor before tender submission. -Site to be surveyed by contractor to obtain levels information prior to commencement of works. All levels given in relation to works to be taken from local ground level. -Do not scale from drawing. 150mm deep hardcore base 150mm deep concrete Existing ground build up 500mm wide exposed concrete band 200mm deep topsoil 350 deep subsoil Grass Lawn Fitting to engineers drawing 4119-221 Berm Details 150mm deep hardcore base 150mm deep concrete Existing ground build up 500mm wide exposed concrete band 200mm deep topsoil 350 deep subsoil Grass Lawn Fitting to engineers drawing 4119-221 Berm Details Cathal O'Meara Landscape Architects 087 9202549 Showgrounds, Fermoy Co. Cork Client:Cork Co. Co. Project: Halfway, Roundabout Drawing: Berm details Date: 11 July 2017 Drawn By: Wendy Kirkpatrick Issue: Tender Dwg No: 1516-104-LA-T003 Scale 1:50, 1:500@ A1 This drawing is the copyright of the Landscape Architect unless otherwise stated. all dimensions are in millimeters. Where dimensions are not given, drawings must not be scaled and the matter must be referred to the Landscape Architect. If the drawing includes conflicting details/dimensions the matter must be referred to the Landscape Architect. All dimensions must be checked on site. The Landscape Architect must be informed, by the contractor, of any discrepancies before work proceeds. THIS IS NOT FOR CONSTRUCTION N Chartered member of the Irish Landscape Institute Halfway roundabout plan with Berm Types. Scale 1:500 1. 1. 1. 1. 1. 1. 1. 2. 2. 2. 2. 3. 3. 3. 3. 3. 3. 3. 3. 01a. Berm Type 1. Plan, Scale 1:50 01b. Berm Type 1. Front, Scale 1:50 01c. Berm Type 1. Axonometric view, Scale 1:50 02a. Berm Type 2. Plan, Scale 1:50 02b. Berm Type 2. Front, Scale 1:50 02c. Berm Type 2. Axonometric view, Scale 1:50 03a. Berm Type 3. Plan, Scale 1:50 03b. Berm Type 3. Section AA, Scale 1:50 03c. Berm Type 3. Axonometric view, Scale 1:50 01d. Berm Type 1. Axonometric view of build up layers Scale 1:50 02d. Berm Type 2. Axonometric view of build up layers Scale 1:50 04a. Concrete Band/Frame Fixing Detail , Scale 1:50 04b. Concrete Band/Frame Fixing Detail , Scale 1:50

Upload: others

Post on 28-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 01a. Berm Type 1. Plan, Scale 1:50 01b. Berm Type 1. Front, Scale … · 2018-01-23 · -All steelwork to be Blast Cleaned to Sa 2.5 of BS 7079: part A1 : 1989. Surface profile to

Me

Me

Me

Me

Me

Me

Me

Me

800050

00

1833

5000

37°

37°

1200

1833

77°

77°

126

10

44

143°143°

103°

103°

6925

6925

6741

8000

8000

5000

1833

5000

37°

37°

1200

1833

77°

77°

126

10

44

143°143°

103°

103°

6925

6925

6741

8000

8000

5000

1833

77°

77°

126

10

44

103°

103°

8000

2836

1594

Mild steel frame painted grey.

Grass turf face.

Gabion face.

Gabion face.

Gabion face. Gabion face.

Grass turf face.

Gabion face.

Gabion face.

Grass turf face.

Gabion face.

Gabion face.

Gabion face.

Grass turf face.

Mild steel frame painted grey.

Mild steel frame painted grey.

Mild steel frame painted grey.

Mild steel frame painted grey.

Ground Level.

200mm Topsoil.

350mm Subsoil.

400mm Hardcore (Min).

Ground Level.

Tree Pit DetailSee Dwg 1516-104-LA-T004

200mm Topsoil.

350mm Subsoil.

400mm Hardcore (Min).

Grass turf face.

Grass turf face.Grass turf face. Grass turf face.

Notes:

-Berm constructed with hardcore to base/core laid in 200mm consolidated layers with 350mm subsoil, turfed faces to be topped with 200mm good quality topsoil (to BS 3882). SeeDetail 01d & 02d-Welded mesh/Stone facing to berms to be constructed using Galfan coated welded mesh, wire diameter 3mm, mesh spacing 50mm x 50mm, to be secured with galvanized gabionclips. Faces to be 100mm deep, length and width to vary with face as shown. Gabions to be filled with 50-70mm dark grey, clean cut stone, from local source to be approved by LA.-Grass faces to Berms to be turfed using 19mm deep 'standard' lawn turf supplied by KMC lawn turf or similar and approved.-Berm frame constructed using mild steel beams, 100mm wide x 6mm deep x length to vary as shown. All welds and fittings to be internal. Frame to be finished using Epigrip C400Epoxy Phosphate Primer/Buildcoat and Martime grade paint such as Leighs EPIGRIPK267HS (RAL7023 Concrete Grey) or similar and approved.-Frame to sit evenly on top of grass and gabion faces with frame secured to concrete base using steel lugs and bolt fittings, to enginneers specification, frame to sit flush withground level.-Concrete parameter stripe foundation for berm to lenght and width of berm frame, 150mm deep with 150mm hardcore base layer, see engineers drawing 4119 -221.-Concrete bands to be 500mm wide, 150mm deep with 150mm hardcore base layer, to engineers specification. Concrete to be poured at the later stages of construction to avoiddamage by construction traffic.-All steel fabrication and erection to be carried out in accordance with the National Structural Steelwork Specification for Building Construction.-All steel to be fabricated, supplied & erected in accordance with BS449 & BS5950.-All connections, welding, etc to be in accordance with the relevant British Standard Code of Practice.-A minimum of 14 working days before fabrication, a complete set of detailed fabrication & / or erection drawings and calculations shall be submitted to the LA for approval.-Fabricator to ensure that all edges have a 2-3mm radius and welds are ground down to prevent any sharp edges.-The steel fabricator shall ensure that all steel components have suitable lifting points for erection and that craneage is adequateand provide any necessary temporary bracing required for erection purposes.-No welding to be carried out on site unless agreed in advance with the National Roads Authority and subject to safety measures being agreed.-All steelwork to be Blast Cleaned to Sa 2.5 of BS 7079: part A1 : 1989. Surface profile to be within the range 30-75 microns typical.

-Drawing to be read in conjunction with:Documents: 1516-Specification, 1516-Preliminaries, 1516-104-SOWLandscape Drawings: 1516-104-LA-T001 Site Location Plan, 1516-104-LA-T002 Landscape Layout, 1516-104-LA-T003 Berm details, 1516-104-LA-T004 Planting plan and details.Engineers Drawings: 4119-221 Berm Details-Any discrepancies regarding measurements, finishes and levels are to be highlighted by contractor prior to commencement on site.-Measurements on drawings are indicative, contractor to check all measurements prior to fabrication to provide information in relation to berm and frames-Any errors or contradictions between drawings/specification/schedule of works to be highlighted by contractor before tender submission. -Site to be surveyed by contractor to obtain levels information prior to commencement of works. All levels given in relation to works to be taken from local ground level.-Do not scale from drawing.

150mm deep hardcore base

150mm deep concrete

Existing ground build up

500mm wide exposedconcrete band

200mm deep topsoil

350 deep subsoil

Grass Lawn

Fitting to engineers drawing4119-221 Berm Details

150mm deep hardcore base

150mm deep concrete

Existing ground build up

500mm wide exposedconcrete band

200mm deep topsoil

350 deep subsoil

Grass Lawn

Fitting to engineers drawing4119-221 Berm Details

Cathal O'MearaLandscape Architects087 9202549Showgrounds, FermoyCo. Cork

Client:Cork Co. Co.

Project: Halfway,Roundabout

Drawing: Berm details

Date: 11 July 2017

Drawn By:Wendy Kirkpatrick

Issue: Tender

Dwg No:1516-104-LA-T003

Scale 1:50, 1:500@ A1

This drawing is the copyright of theLandscape Architect unless otherwisestated. all dimensions are in millimeters.Where dimensions are not given, drawingsmust not be scaled and the matter must bereferred to the Landscape Architect. If thedrawing includes conflictingdetails/dimensions the matter must bereferred to the Landscape Architect. Alldimensions must be checked on site. TheLandscape Architect must be informed, bythe contractor, of any discrepancies beforework proceeds.

THIS IS NOT FORCONSTRUCTION

N

Chartered member ofthe Irish LandscapeInstitute

Halfway roundabout plan with Berm Types.Scale 1:500

1.

1.

1.

1.

1.1.

1.

2.

2.

2.

2.

3.

3.3.

3.3.

3.

3.

3.

01a. Berm Type 1. Plan, Scale 1:50 01b. Berm Type 1. Front, Scale 1:50 01c. Berm Type 1. Axonometric view, Scale 1:50

02a. Berm Type 2. Plan, Scale 1:50 02b. Berm Type 2. Front, Scale 1:50 02c. Berm Type 2. Axonometric view, Scale 1:50

03a. Berm Type 3. Plan, Scale 1:50 03b. Berm Type 3. Section AA, Scale 1:50 03c. Berm Type 3. Axonometric view, Scale 1:50

01d. Berm Type 1. Axonometric view of build up layers Scale 1:50

02d. Berm Type 2. Axonometric view of build up layers Scale 1:50

04a. Concrete Band/Frame Fixing Detail , Scale 1:50 04b. Concrete Band/Frame Fixing Detail , Scale 1:50