UTC Fire & Security EMEA Distribution
ATS Product Presentation
15/02/2011
2 /UTC Fire & Security/
Agenda
•Introduce Participants/Trainer•ATS product range overview•Management software possibilities•Practice/exercise•Questions
3 /UTC Fire & Security/
A True Family concept
• Available in different sizes• Integration of intrusion and access control• All panels run on the same software• One user interface• All panels can work with all accessories• Upgrade from:
ATS1000>ATS2000>ATS3000>ATS4000
4 /UTC Fire & Security/
ATS Panels
ATS1000
ATS4000
ATS4500
ATS3000
ATS2000
5 /UTC Fire & Security/
Everything you need!
• Management Software adds CCTV & Fire
• Alarm reporting through all communications media
• Hardwired, wireless, addressable inputs
6 /UTC Fire & Security/
ATS Hardware - Overview
ATS1000 ATS2000 ATS3000 ATS4000
Power 1A 2A 2A 2A
Inputs on board 8 8 8 16
Max inputs 32 64 128 256
Std outputs on board (oc-relay) 4 4 4 4
Max outputs (relay/op) 128/ 256 128/256 128/ 256 128/ 256
Max battery in box 2x7.2Ah 18 Ah 18 Ah 2x7.2Ah// 18Ah
7 /UTC Fire & Security/
ATS Hardware - Overview
ATS1000 ATS2000 ATS3000 ATS4000
Memory extension 1/4/8Mb No Yes * Yes * Yes
Max readers (RAS; Remote Arming Station)) 16 ** 16 16 16
Max DGP (DGP= Data Gathering panel) 15 15 15 15
Wireless (ATS1234) Yes Yes Yes Yes
Access control (ATS1250) No Yes Yes Yes
Transmission PSTN/ISDN/GSM Yes Yes Yes Yes
Transmission TCP/IP (ATS1809) No Yes Yes Yes
8 /UTC Fire & Security/
ATS Memory - Overview
ATS1000 ATS2000 ATS3000 ATS4000
Alarm groups (Std/max) 128 128 / 138 128 / 138 128 / 138
Door groups (Std/max) 10 10 / 138 10 / 138 10 / 138
Time zones (Std) 24 24 24 24Holidays (Std/max) 24 24 / 64 24 / 64 24 / 64History – intrusion (Std/max) 200 200 / 1000 200 / 1000 200 / 1000History – Access (Std/max) 10 10 / 1000 10 / 1000 10 / 1000Macro logics 24 24 24 24Max users (standard ) 50 65000 65000 65000Max users (configuration soft IUM) 50 2000 2000 65000
Central stations 4 4 4 4
9 /UTC Fire & Security/
ATS Control panels General Features• On-board zones and local Zone expansion• Local output expansion• ATS control Panel data bus to connect Data
Gathering Panels (DGP’s)• Switched mode power supply
- Battery deep discharge protection- Dynamic battery testing
• External siren with driver option• On-board PSTN dialer• MI extesion bus
10 /UTC Fire & Security/
ATS Control Panels Customised solutions; standard components(Input) Events can be customised to have a conditional output
Pre-programmed zone types already offer 98% of the common required conditions
24 Macro logical equations will complete the remaining 2% of the special required conditions
INPUTOUTPUT
Kernel
Event Handler
Zone 1....................
Zone 256
Type 1....................
Type 71
EF 1 Output 1....................
Output 255
Output ConditionInput Condition
.....
.....
.....EF 255
ATS MASTER Decision Model
INPUT OUTPUT
11 /UTC Fire & Security/
Modular: Growing with customer needsAdd new components without replacing the initial equipment
IC3
ATS7100/ATS7110
12 /UTC Fire & Security/
ATS Layout
+12 , 0V, D+, D- = Databus
A, B = PSTN line inAx, Bx = Line out
Main power/ Battery
Inputs : 1t/m 8
13 /UTC Fire & Security/
ATS Connections
RS232 to Titan via ATS1630 serial cable
ATS1801/1802
Opt. Memory
TST1 Jumper
To ATS1202
Zone 9-16 active
To ISDN, GSM, voice or ISDN interface
LK18 = KILLBack to default setting
To ATS1810/1811/1820
14 /UTC Fire & Security/
Outputs onboard
External Siren EOL (1K) (12V of Driver)
Internal Siren
Panel outputs Panel Output nr.External Siren (12 V of Driver) ATS 1/2/3/4000 16Internal Siren (12 V) ATS 1/2/3/4000 15Strobe (12 V) ATS 2/3/4000 2Relais (C/NO/NC) ATS 3/4000 3SW + SW - (12 V) ATS 3/4000 251
Strobe (12V)
15 /UTC Fire & Security/
ATS Control Panel Data BusEvery ATS Control Panel includes a RS485
system databus to connect:
> A maximum of 15 Data Gathering Panels (DGP) to provide extra zones and outputs
> A maximum of 16 Arming Stations (RAS) which can be any combination of keypad or reader
> Remote devices can be up to 1.5 km from an ATS control panels. RS485 data busx 16 RAS x 15 DGP
16 /UTC Fire & Security/
ATS Control Panel Data Bus
A physical connection between 2 or moreTo communicate to;
ATS4001Panel
ATS1201DGP
ATS1100RAS
DisplayATS1100RAS
DisplayATS1201
GPIATS1201
DGP
Max. 1,5 km FTP or STP CAT5 kabel
Max. 16 RAS’s Max. 15 DGP’s
T T
T Terminator setBus001 Rev.01
17 /UTC Fire & Security/
ATS Control Panel Data Bus TopologyWhich network structures are allowed?
Point to Point 1 2
Daisy chain 1 322 3 ....
Backbone with stubs (max. 9 meter)
1 72 4 5
3 6
18 /UTC Fire & Security/
ATS1210/1211 DGP
8 C 7 6 C 5 4 C 3 2 C 1 Inputs
J4 to ATS 1810,1811,18
20
Power + DataDGP Address
19 /UTC Fire & Security/
ATS1201 DGP
DGP Address
options
ATS 1810/1811/18
20
Ext. Siren Output
8 Inputs Tamper Data bus +12v, 0v, D+, D-
Terminator
To 1202
20 /UTC Fire & Security/
ATS 1202 Input expansion
Zone n° to useSW1 SW2 SW3 SW4print n° 1 : 9-16 ON OFF OFF OFFModule n° 2 : 17-24 OFF ON OFF OFFModule n° 3 : 25-32 OFF OFF ON OFF
J2 J2
J2
J3 J3
J3Naar DI
21 /UTC Fire & Security/
DGP with ATS1202 expanders
PanelRAS DGP DGP DGP
• Expansion with 8 inputs per ATS1202• Max. 32 inputs per DGP
22 /UTC Fire & Security/
ATS components Bus accessories
>ATS1740 Isolators>ATS1744 Data bus isolators>ATS1742 Closed loop modules>ATS1741 RS485 - RS232 converters>ATS1743 RS485 - Fiber modules
23 /UTC Fire & Security/
ATS1744
4 way DATABUS ISOLATOR / REPEATER
24 /UTC Fire & Security/
ATS 1744 possibility
DATABUS
Panel
25 /UTC Fire & Security/
ATS 1744 possibility
DatabusPanel
AATS1744 BC D
E
Terminator set at A, B, D en ENo terminator set to C
Max length1500 m for AB en 1500 m for DE
26 /UTC Fire & Security/
ATS 1744 possibility
DatabusPanel
A
B
C ED2
ATS1744
ATS1744
Terminator set B, C, D and ENo terminator at A
Max length 1500 m for DE and for BC
27 /UTC Fire & Security/
ATS 1744 possibility
BUS DATAABCD
Panel
max. 1500m max. 1500m max. 1500m
Bus DataBCD
Bus DataBCD
Aux power+12V to AGND to B
Aux power+12V to AGND to B
A AB B
• Max. 4 x ATS1744 at one panel• Max length = 1500 m per databus• Use external power supply (dist. = > 100m)• Set terminators like normal databus
28 /UTC Fire & Security/
Advanced Wireless DGP ATS1234 -> 868 MHz, FM> Mother / Daughter board concept to meet local frequency and
security requirements> Range sensitivity & noise floor level indication> Range reduction test for commissioning> Up to 15 DGP’s connectable
29 /UTC Fire & Security/
Advanced Wireless DGP System Overview
> ATS4000 can connect up to 240 wireless devices> Up to 400 m range
1 2 8/15
max. 32 max. 32 max. 32
30 /UTC Fire & Security/
Intelligent Addressable System System Overview
ATS4000 can connect up to 240 addressable devices
max. 16max. 16
max. 32
31 /UTC Fire & Security/
Intelligent Addressable System Why Addressable Detectors?
Installer benefits> Cut down the installation time> Just 2/4 wires + address dip-switch> No detector configuration dip-switches> Less cable and connections, no EOL Resistors> Range, LED, walk-test… configured by TITAN> More options for diagnostic/service> Easier to extend a system> Commission report> Free topology possible
– No re-cabling required– Easy to install and extend
32 /UTC Fire & Security/
Cabling costs ATS addressable busReduced cabling lengthand number of connections (no “home-runs” from each detector)
Lower 2-wire cable cost (no expensive Cat 5)
Higher security (eachdevice has a unique ID)
Full free topology – Easy to add on devices
Enhanced remote diagnostics
33 /UTC Fire & Security/
ATS Product Overview
Integrated Access Control
34 /UTC Fire & Security/
ATS components Accessories Miscellaneous>Memory expansions (1, 4 or 8MB)>Extend the number of users>Supports all Wiegand readers up to 48 bits>Different card formats on one system>Learning mode
>Cards>Card Programmers>Colored covers (ATS1190)
35 /UTC Fire & Security/
Integrated Access Control
Flexible and Highly Secure Most systems work according to an ON/OFF modeThe ATS is much smarter> Copes with flexibility of working schedule> Deals with:
– Contractors & cleaning staff– Security staff– Facilities open 24hr/24hr– High security applications– Banking, vault & ATM applications
36 /UTC Fire & Security/
Integrated Access Control
>Standard door access functionality to 16 doors (connected to main panel)
>Readers and keypads on the BUS>Reader interface to adapt 3rd party reader >Time zone programming>Holiday programming>Flexible card / PIN configuration
37 /UTC Fire & Security/
Access ControlDoor Access definition
•Door access provides means for managing access through doors based on a valid credential (PIN, Badge or both), valid access rights within specified time periods
•Most common type of access required
38 /UTC Fire & Security/
ATS Keypads and Readers
>ATS111x Keypads with or without integrated card reader
>ATS115x Robust PIN / Card + PIN reader>ATS116x Mifare Card/Card + PIN reader>ATS119x Card / Card + PIN readers> Can be connected to the communication
bus
39 /UTC Fire & Security/
RelationIntrusion - Access
Keypads Users
Door/Floor groupsAlarm Groups
Areas Timezones Doors
Readers
40 /UTC Fire & Security/
ATS Product Overview
Communication
41 /UTC Fire & Security/
Communication
Directly from panel to comport PC (ATS1630)- limited time, max. 4 hours.> - access via service menu (menu 7>5)
> Computer interface (ATS1801/ATS1632)> - permanent connection
42 /UTC Fire & Security/
ATS Control Panels Communication
All ATS Control Panels are provided with an onboardPSTN dialer for:
> Central Station Reporting> Remote up- / downloading> Management Connections
RS232 programming port forConfiguration
Optional ATS1801 communication modulefor permanent management connection
43 /UTC Fire & Security/
Connection by using J18.(RS232)
• Press menu + 1278 + enter• Go to menu 7 + enter• Press code 1278 + enter• Press 5 + enter, for direct connection• Press “clear” > display showed “REMOTE”• Select “activate” In TITAN
This connection is made by using cable ATS1630
44 /UTC Fire & Security/
Connection by using the ATS 1801• Direct connection can be made by TITAN
• Direct connection is not time limited
This connection is made by using cable ATS1632
45 /UTC Fire & Security/
RS232
Requirements :>shielded>length: 15 m official
Advise :>Use datacable CAT5 shielded or better>length: about 30 m possible
(surroundings depends)
46 /UTC Fire & Security/
Solution
ATS4001Paneel
ATS1201DI
ATS1100GI
DisplayATS1100
GI
DisplayATS1201
DIATS1201
DI
Max. 1,5 km FTP of STP CAT5 kabel
Max. 16 GI's Max. 15 DI's
ATS1801
ATS1741
ATS1741
PM811
Titan systeem
T Terminator geplaatst
T
T
T T
Bus009 Rev.01
Max. 1,5 km FTP ofSTP CAT5 kabel
Max. 30 m FTP of STP CAT5 kabel
47 /UTC Fire & Security/
ATS Reporting All communication Paths available
48 /UTC Fire & Security/
ATS Reporting Alarm Reporting Centre
4 Central Stations / 2 phone numbers per CS
ATS Control Panel
Transmission link
CS 1
CS 2
CS 3
CS 4
49 /UTC Fire & Security/
ATS Control Panels MI extension busAll ATS Control Panels are provided with a MI
extensionbus to connect:
•ATS712x ISDN (EURO)
•ATS7300/7310 GSM
•ATS7200 Voice
IP Connection ATS1809
ATS1809 Universal Interface
51 /UTC Fire & Security/
ATS1809 Universal InterfaceOutcome•Know how to connect ATS1809•Know how to configure ATS1809
52 /UTC Fire & Security/
ATS1809 Universal InterfaceFeatures•μC Linux-based•Connects to ATS1801•Two purposes:
>management application connection (Alliance)>reporting to IP receiver (GE Network Receiver)
•Web-browser configurable•Strong encryption
53 /UTC Fire & Security/
ATS1809 Universal InterfaceRequirements• Use version 00.06.09 or later
> flash upgrade> Wire RTS/CTS signals
• Configure ATS Panel’s computer address (Installer menu 29) Address 0 not allowed
• Jumper DEF for default IP address (192.168.0.100)• Obtain from locale IT following IP network settings
> static IP address> network mask> gateway address
54 /UTC Fire & Security/
DEFNot used
RST
ATS1809 Universal InterfacePCB
DEF – Default IP addressRST – ResetRS232 panel comms
55 /UTC Fire & Security/
ATS1809 Universal InterfaceComputer settings•Select “Use the following IP address”
>IP: 192.168.0.X (last octet “X” not 100)>Subnet: 255.255.255.0>Gateway: if required
•Web browser: >Disable Auto detect settings or auto configuration
56 /UTC Fire & Security/
ATS1809 Universal InterfaceConfiguration•Open web-
browser and enter default IP address: 192.168.0.100
• Click “Login”
57 /UTC Fire & Security/
ATS1809 Universal Interface
•Login>Username & password:
– ADVISOR MASTER– 998765
•Static Address Parameters>Enter IP address>subnet mask >gateway address
58 /UTC Fire & Security/
ATS1809 Universal InterfaceCentral Station Parameters• Configure connection list
>First 3 Stations for GE Network Receiver>Consider use of Two fish Encryption
Alarm
Management
{{
59 /UTC Fire & Security/
ATS1809 Universal InterfacePanel configuration• Panel Physical Address
• Panel computer address (same as installer menu 19 >> 29)
•Panel Security Password •Always submit changes•Then select “Restart
Communications” to activate settings
60 /UTC Fire & Security/
ATS1809 Universal InterfaceFirewall• Consider use of
firewall • Set default rule to
deny all connections• Set rules to open all
ports for specific IP address
> Management application (UDP)
> ATS1806 Web browser (TCP, 80)
61 /UTC Fire & Security/
ATS1809 Universal InterfaceTroubleshoot• Check if red & green LED
both flash (indicate 1809 <> panel comms)
• Ping static address• Use web browser• Check through browser
> IP address, port, encryption> Encryption key> Panel/computer address> Security password
62 /UTC Fire & Security/
ATS1809 Universal InterfaceExercise•Make connection to Universal Interface via
web browser•Configure the UI using the guidelines
above>Configuration as defined in class
•Troubleshooting>Ping for standard troubleshooting>Ethereal/WireShark or equivalent for advanced
troubleshooting
63 /UTC Fire & Security/
TITAN Software
Windows Vista
64 /UTC Fire & Security/
ATS8100 TITAN Standard Configuration package + simple management
• ATS configuration package• Commisioning and maintenance tool• Easy database switching• Multiple systems, multiple panels in system• Single client, single user access• Connect directly (RS232), PSTN, GSM, ISDN
• All functionalities for daily user management
65 /UTC Fire & Security/
ATS8100 TITAN Standard TITAN Diagnostic™
There is no equivalent in the market !EN50131 maintenance requirements> Full remote diagnostic> Remote maintenance > Tool for on site commissioning
66 /UTC Fire & Security/
ATS8100 TITAN Standard Remote services
TITAN remote services • 100% of the ATS commands are accessible remotely
using TITAN:– Set / Unset areas individually– Unlock doors, inhibit detectors, – enable / disable users– …and much much more
67 /UTC Fire & Security/
.
68 /UTC Fire & Security/