01-02 bts3012 common subsystem
DESCRIPTION
CommonTRANSCRIPT
2 BTS3012 Common Subsystem
About This Chapter
The BTS3012 common subsystem performs the following functions: transferring E1 signals,providing clock reference for the BTS, collecting and monitoring environment alarms, andsynchronizing the BTS with the entire network.
2.1 Components of the BTS3012/BTS3012AE Common SubsystemAs the functional body of the BTS3012/BTS3012AE common subsystem, the common subrackconsists of the DTMU, DATU, DCSU, and DCCU.
2.2 Functions of the BTS3012/BTS3012AE Common SubsystemThe BTS3012/BTS3012AE common subsystem manages and controls other subsystems andmodules. It performs the following functions: introducing E1 signals into the BTS, providingclock reference for the BTS, collecting and monitoring the environment alarms, andsynchronizing the BTS with the entire network.
BTS3012Product Description 2 BTS3012 Common Subsystem
Issue 01 (2007-06-30) Huawei Technologies Proprietary 2-1
2.1 Components of the BTS3012/BTS3012AE CommonSubsystem
As the functional body of the BTS3012/BTS3012AE common subsystem, the common subrackconsists of the DTMU, DATU, DCSU, and DCCU.
Internal CompositionFigure 2-1 shows the configuration of boards in the BTS3012/BTS3012AE common subrack.
Figure 2-1 Configuration of boards in the BTS3012/BTS3012AE common subrack
DTMU
DTMU
DEMU
DCSU
DCCU
DATU
0 1 2 3 4 5 6 7
Table 2-1 lists the relation between the boards and the slot numbers.
Table 2-1 Relation between the boards and the slot numbers in the common subrack of theBTS3012/BTS3012AE
Board Slot No.
DTMU Slots 0 and 1
DEMU Slots 2, 3, 4, or 7
DATU Slots 2, 3, 4, or 7
DCSU Slot 5
DCCU Slot 6
NOTE
The DTMU is a mandatory board that supports active/standby mode. A maximum of two DTMUs can beconfigured.
The DEMU is not configured in the common subrack of the AC BTS3012AE cabinet.
External CablingFigure 2-2 shows the external cabling of the BTS3012/BTS3012AE common subrack.
2 BTS3012 Common SubsystemBTS3012
Product Description
2-2 Huawei Technologies Proprietary Issue 01 (2007-06-30)
Figure 2-2 External cabling of the BTS3012/BTS3012AE common subrack
DTMU
DCCU
DEMU
DATU
DCSU
Ethernet cables
E1 signal transfer cableFAN subrack
signal transfer cable
Boolean valuesignal transfer cable
RET control signal cable
Signal cable between the DCCU/DCSU and the DSCB(BTS3012AE)
Signal cable between the DCCU/DCSU and the DCTB(BTS3012)Signal cable between the
DCSU and the DTRB
Common subrack
2.2 Functions of the BTS3012/BTS3012AE CommonSubsystem
The BTS3012/BTS3012AE common subsystem manages and controls other subsystems andmodules. It performs the following functions: introducing E1 signals into the BTS, providingclock reference for the BTS, collecting and monitoring the environment alarms, andsynchronizing the BTS with the entire network.
The common subsystem performs the following functions:
l Managing and controlling other subsystems and modules
l Connecting the BTS with the BSC through E1 links: Four routes (default) or eight routes(when specified) of E1 signals are supported.
l Outputting digital alarm signals and extended digital control signals
l Providing and managing clock reference (and hot backup) for the BTS
l Synchronizing the BTS with the entire network, and implementing the BITSsynchronization clock input
l Maintaining and monitoring the BTS equipment
l Guaranteeing the normal operation of the equipment by monitoring and collecting smoke,water, temperature, humidity, infrared, and door alarms
l Reporting alarms associated with the Remote Electrical Tilt (RET) antennas and feedcurrent
BTS3012Product Description 2 BTS3012 Common Subsystem
Issue 01 (2007-06-30) Huawei Technologies Proprietary 2-3