Motor control and protection Control and signalling Circuit protection and isolation Automation and control Energy management Index Motor protection circuit breakers Contactors Motor protection relays Electromechanical starters Soft starters AC motor drives Pushbuttons and selector switches Signal towers and beacons Limit, micro and foot switches Rotary cam switches Switch disconnectors Fuse holders and fuses Miniature and residual circuit breakers Surge protection devices Modular contactors Earth leakage relays Time relays Protection relays Level control relays Micro PLCs Switching power supplies Automatic battery chargers Metering instruments and current transformers Power factor controllers and thyristor modules Automatic transfer switch controllers Engine and generator controllers Software and applications Expansion modules and accessories 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 I 0 NEW NEW

Upload: alphaaaaaa

Post on 10-Dec-2015

275 views

Category:

Documents


26 download

DESCRIPTION

catalogue

TRANSCRIPT

  • Motorcontrol andprotection

    Control andsignalling

    Circuitprotection

    and isolation

    Automationand control

    Energymanagement

    Index

    MON

    ENT

    RUN

    STOP

    Motor protection circuit breakers

    Contactors

    Motor protection relays

    Electromechanical starters

    Soft starters

    AC motor drives

    Pushbuttons and selector switches

    Signal towers and beacons

    Limit, micro and foot switches

    Rotary cam switches

    Switch disconnectors

    Fuse holders and fuses

    Miniature and residual circuit breakers

    Surge protection devices

    Modular contactors

    Earth leakage relays

    Time relays

    Protection relays

    Level control relays

    Micro PLCs

    Switching power supplies

    Automatic battery chargers

    Metering instruments and current transformers

    Power factor controllers and thyristor modules

    Automatic transfer switch controllers

    Engine and generator controllers

    Software and applications

    Expansion modules and accessories

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    I

    OFF

    0

    ON

    EARTH LEAKAGE RELA

    R1

    TEST

    RESET

    FUNCTIO

    auto rese tx1

    I nx

    I nx1

    man resetx

    0,2

    0,

    11,

    2

    2,O

    TRI

    I n (A

    t (sec0,00,00,

    0,0, 0,

    0,

    I n SCALE SETTIN

    auto rese tx1

    I nx

    I nx1

    man rese

    tx

    I nx0,

    auto rese tx1

    I nx

    I nx1

    man rese

    tx

    I nx0,

    auto rese tx1

    I nx

    I nx1

    man rese

    tx

    I nx0,

    I nx0,

    I nx0,

    I nx

    I nx1

    CN25.

    10

    A1

    13

    5 13 (7

    )

    A2

    24

    6 14 (8

    )

    24V

    50/60H

    z

    Modul

    ar cont

    actor

    13

    5 13(7

    )

    2

    NEW

    NEW

  • 2014 new products

    Insulatedpolycarbonate IP65enclosures

    A new frame size allowsmounting direct-on-linestarters and changeovercontactor assemblies up to38A.Available in two versions, witha deep cover (M25) or ashallow one (M24), fordifferent configurations ofelectromechanical orelectronic devices which canbe fixed to the standardsupplied metal plate.

    ADXC soft startersADXC soft starters have a45mm wide casing. They canbe installed either on 35mmDIN rail or fixed on amounting plate, by scews, aresuitable for soft start andstop, by current limitation, ofthree-phase asynchronousmotors rated up to 45A.Alarms are available, acrossthe range, for overcurrent,over temperature and overvoltage conditions. The 600Vversion is also equipped withtwo relay outputs for remotesignalling of alarms andbypass relay closing.

    Spring-clampterminal contact andLED elements

    LOVATO Electric addnew spring-clampterminal types to theexisting screw andfaston terminalcontact and LED

    elements, all to be mountedon the LPXAU120 adapter. This type of push-inconnecting technology is timesaving during wiring since itis a tool-less operation.

    Auto-monitor contactelements

    These particular NCcontacts, used withnon-illuminated latchemergency stoppushbuttons, providefor constant monitoring

    of exact mounting andoperation of the NC contacts.Once the contacts areinstalled on the mountingadapter in a correct way andwith a correct running of theequipment, they work asnormal NC contacts.Their trait is to break tonormally-open state and, inso doing, isolate the circuitwhen malfunctions takeplace, for instance after thecontact detaches from theadapter or if these two comeloose from the pushbuttonitself, due to strong vibrationsor shock of some sort.

    Control stations andbase-mount contactand LED elements

    LOVATO Electricrelease the newinsulatedpolycarbonate LPZcontrol stationsfeaturing modern

    design and aesthetics in linewithpushbuttons and selectorswitches.The types include emptystations, with 1 to 6 holes,having excellent protectiondegrees per IEC IP66, 67,69K and UL Type 4/4X. Theextreme sturdiness allowsuse in every type ofapplication. To ease wiringinside the new LPZpushbutton stations,dedicated contact and LEDelements have been made todirectly fit onto the controlstation base. This sort ofinstallation provides for allwiring to be entirely withinthe base. As a result, coveropening and fixing are safe,quick and simple operations.

  • IP65 enclosed switchdisconnectors

    LOVATO Electric havecompleted the line ofenclosed switchdisconnectors by introducinga new enclosure frame size inbetween the two availableGAZ1 and GAZ3 types. Thenew GAZ2 version is availableempty or already completewith either a three or four-pole switch disconnector,rated 63A, 80A or 100A inIEC AC21A duty. The IP65protection degree allowsthem to be installed in severeambient conditions. This product range has beenextended to include newchangeover switches, in boththree and four-pole versions,rated 25A to 125A in IECAC21A duty, housed ininsulated enclosures.

    Fuse holders 10x38size

    The range is composed of:one-pole, one-pole with lightindicator, one-pole + neutral,two-pole, three-pole andthree-pole + neutral versions.Using the availableaccessories, multi-pole typescan be assembled startingfrom the single-pole device.In addition, there is aninsertable label to identifyeach single pole. ULcertifications, as Listed orRecognized (cULus or cURus)for USA and Canadadepending on type, have nowbeen obtained for all10x38mm fuse holders, bothAC and photovoltaic DCversions.

    Miniature andresidual circuitbreakers

    LOVATO Electric include in itsproduct offering new modulardevices dedicated to protectpeople and installations. Theyare miniature circuit breakers(MCBs) up to 125A andresidual current circuitbreakers (both RCBOs andRCCBs). The MCBs have a highbreaking capacity of 10kAand most are certified by ULfor USA and Canada assupplementary protectors perUL 1077.

    Surge protectiondevices

    LOVATO Electric release twonew types of surge protectiondevices for photovoltaicapplications, compliant withthe new EN 50539-11standard. The new products, availablewith removable plug-incartridges, are used ininstallations with voltage upto 1200VDC. By using theircontact remote feature,indication of the device statuscan be remoted so as tosignal when replacement isneeded. The new SPDs havehigh Iscpv short-circuitcurrent rating up to 1000A.This current value is veryimportant because itindicates the maximumcurrent which their thermaldisconnector is capable ofisolating.

    Interface protectionPMVF 51

    The PMVF 51 interfaceprotection gives all thefunctions and controlsrequired by the Italian CEI 0-21 standard (June 2012edition and subsequentrevisions) regarding low-voltage connection of micro-generation systems, such assolar or wind installations,between the energygeneration system and thenational power grid. Inaddition to compulsoryvoltage and frequencycontrols, when currenttransformers are connectedwith the PMVF51 interfaceprotection, it can also put atdisposal current and energymeasurements as well asunbalanced power controlwith the optional dedicatedexpansion module installed.

    New design for the direct operating and door-couplinghandles introduced for GE switch disconnectors - 160 to 1600A ratings.OFF and ON positions are clearly and preciselyidentifiable.

    New GE series handles

  • Micro PLC with built-in RS485

    LRD20R D024 P1is a new version ofthe Micro PLCs,featuring integratedRS485 serialinterface, whichprovides for simple

    automated functionintegration, typical of the LRDseries with supervision andcontrol software.Transducers, field and usercommands can all be easilyelaborated by the Micro PLCto program its outputs.

    Automatic batterychargers BCG

    The new BGC battery chargerseries introduces switchingtechnology even for the 12A12VDC and 10A 24VDCratings of lead-acid batteryapplications. Two voltagelevels can be selected,suitable for different sorts ofbattery and maximumcharging current can beadjusted. The batterychargers are enhanced byautomatic protections andindication LEDs for alarmand battery operatingconditions. The relay output isautomatically activatedwhenever a malfunction ofthe system takes place.

    Digital multimetersDMG 600 - DMG 610(96x96mm)

    DMG6 digital multimeters,for single or three-phasesystems, permit to viewelectrical quantities of theinstallation on their backlightLCD screen and, by installingone of the EXP seriescommunication modules(USB, RS232, RS485,Ethernet), thesemeasurements can beaccessible to the supervisionsoftware via appropriateprotocol. The DMG 610 type is alreadyequipped with built-in RS485interface. Data collection canbe done directly on themultimeter front as well, byconnecting the CX01 or CX02dongle to its optical port,without having to open theelectrical panel.

    DME energy metersFour new models completethe existing range: DME D115 T1 (40A singlephase, 2-module type)improves legibility ofinstallation energy and powermeasurements by users,DME D130 (63A singlephase) is expandable withEXP series modules (e.g. forload supervision); while DME D121 (63A singlephase) and DME D320 (CT/5A three phase) have a built-in RS485 communication portmaking these two directlyintegrable in supervisionsystems. Therefore, acquired data ofthe energy meters can becentralised and thendeveloped with softwareelaboration.

    Data concentratorDME CDPV1 forphotovoltaicmonitoring

    DME CDPV1 is a devicespecifically for monitoringphotovoltaic installations. Byconnecting at least two singleor three-phase DMED energymeters to the data concentratorin an installation, the user canobtain energy produced by thePV installation, energy drawnby loads and ultimately, energyexchanged (import and export)with the energy provider.DME CDPV1 is already dulyprogrammed to automaticallycalculate the percentages ofproduced (total and partial) andconsumed apparent power,average power values and theoperating status of the AC/DCinverter (if it is equipped withany digital outputs).It is customisable by the userby setting up additional valuesto control the installationefficiency. In addition, with theEXM series expansion modules,DME CDPV1 can also be usedto supervise loads according tologic functions, defined by theuser and based on the energyavailability. By adding anEthernet communication port inaddition to the RS485 alreadybuilt in, remote control andsupervision can be done by the

    software..

    2014 new products

    The new software is based on the most moderntechnology that provides for the management ofmulticlient access through Web browser, thus allowingsupervision and control of installations by any computerwhatsoever.Graphic pages, data logs and trend graphs can becreated and easily navigated. Moreover, alarms andfunctions can be operated to send emails withnotifications and reports.

    supports all LOVATO Electric productsequipped with communication interface.

    Supervision and energy management software

  • Current transformerDM0T

    LOVATO Electric extend theseries of its solid-core currenttransformers to include newDM0T 50 to 150A types.The new transformers aretested according to a class 1accuracy and reduce linecurrent to a 5A secondaryvalue. They have screwterminals on the secondaryand sealable terminal blocksare standard supplied.

    Automatic powerfactor controllersDCRL (96x96mm)

    The new DCRL3 and DCRL5power factor controllers have3 and 5 steps respectivelybuilt in to connect capacitorbanks. When needed, twoextra steps can be added byinstalling the EXP10 06expansion module to obtain amaximum of 7 steps in total. The backlight icon LCDviewing is made up ofsymbols and texts which offera clear, intuitive image of theinstallation status. Thecontrollers are equipped withall the functions and alarms toguarantee long capacitorbank life.An optical communicationport is available on thecontroller front and providesfor controller setup,programming and datacollection for diagnotics andelaboration, in a safe way, byusing the CX01 or CX02dongle, without having todisconnect and open theelectrical panel.

    Automatic transferswitch controllersATL 600 / 610(144x144mm)

    The automatic transfer switchcontrollers ATL 600 and ATL 610 permit to supervisetwo power sources interactingwith the user through thebacklight graphic LCD andLED synoptic capable ofviewing the installation status,with complete text andgraphs.The ATL 610 version has the12 or 24VDC supply inputs inaddition to the 110240VACinputs of the ATL 600 type,and comes equipped with twoexpansion slots for EXP seriesmodules to combineadditional digital inputs andoutputs and communicationfunction, such as USB,RS232, RS485, Ethernet. Inthis way, the ATS switchboardcan be remotely controlledthrough supervision software.

    Dual power supplymodule ATL DPS1

    LOVATO Electric release adual power supply module forthe product offering ofautomatic transfer switching.This new device is capable ofchecking the voltage values atits inputs and identifyingwhich is the ideal to use andconnect to its output. ATL DPS1 is suitable tosupply motorised changeoverswitches and circuit breakers.The module functionality isdone by a microprocessor.The two single-phase voltageinputs are independent,isolated from each other andeach capable of supplying theinternal measuring circuit.Additional controls are madeon the output voltage to checkthat the device operation iscorrectly carried out. In caseof malfunction, the red LEDwill switch on to signal it;voltage flow is stopped andnot available at outputterminals. The green LEDs onthe module front permit toconstantly monitor the statusof the power sources,availability of input lines andpresence of the moduleoutput voltage.

    APP Configuration andmaintenance operations, oftendone in intolerable ambiancedue to weather or noisyconditions, are now easier todo for all LOVATO Electricproducts with communicationinterface on front compatiblewith CX02 dongle. Indeed,tablets and smartphones withAndroid or iOS operatingsystem can connect to themusing the new applicationcalled directlydownloadable from GooglePlay or iTunes. Therefore, it isno longer necessary toconnect and switch on a PCusing cables to changeconfigurations, set upparameters or even clonedevice programming. Withthis APP, a file previouslysaved can be uploaded;commands can be sent;measured quantities can beread from LOVATO Electricdevices. The events can beviewed and saved in a text fileand later copied and sent byemail.

    The CX communication dongles available as USB andWi-Fi versions allow connection between tablets,smartphones, PCs and LOVATO Electric products withfront optical communication interface.

    Communication devices CX

  • The story of a family,the spirit of a company

    Italian designIn the Bergamo headquarters, the research staff and designexperts develop both innovative and reliable products bytaking advantage of the most modern tool and softwaresystems available in the marketplace.

    Since 1922LOVATO Electric head offices were first established inBergamo, Italy, in 1922: the starting point of a greatindustrial adventure. The Cacciavillani family hasmanaged the company for four generations.

  • Making reliable, innovative products andoffering services to meet customersexpectations, continue to be our companysmission since four generations.

    MMassimiliano CacciavillaniManaging Director

    Leading-edge manufacturing facilitiesLOVATO Electric design and make products with the mostadvanced technology.

    Highly qualified technical assistanceA team of specialised technicians provide quick and professionalassistance relating to products and applications.The Technical Assistance office specialises in all pre- and post-salesactivities giving customers all the necessary support for:

    - Product selection

    - Certifications

    - Product commissioning

    - Assistance in case of malfunction

    - Product designation

    - Cross-reference withcompetitors products

  • LOVATO Electric presence in the major world markets is the resultof the perpetual internationalisation strategy. LOVATO Electric Italy together with its foreign subsidiarycompanies and network of importers represent the referencepoint for the global distribution of its products in over 100 countries.

    International presence

    UNITED STATESOF AMERICA

    LOVATO ELECTRIC INC.www.LovatoUsa.com

    CANADALOVATO ELECTRIC CORP.

    www.Lovato.ca

    SPAINLOVATO ELECTRIC S.L.U.

    www.LovatoElectric.es

    GERMANYLOVATO ELECTRIC GmbH

    www.LovatoElectric.de

    POLANDLOVATO ELECTRIC SP. Z O.O.

    www.LovatoElectric.pl

    CHINALOVATO ELECTRIC (SHANGHAI) CO LTD

    www.LovatoElectric.cn

    TURKEYLOVATO ELEKTRI

    .K LTD

    www.LovatoElectric.com.tr

    ROMANIALOVATO ELECTRIC SRLwww.LovatoElectric.ro

    UNITED ARABEMIRATES

    LOVATO ELECTRIC ME FZEwww.LovatoElectric.ae

    CZECH REPUBLICLOVATO ELECTRIC S.R.O.www.LovatoElectric.cz

    UNITED KINGDOMLOVATO ELECTRIC LTD

    www.Lovato.co.uk

    ITALYLOVATO ELECTRIC S.p.A.www.LovatoElectric.com

  • 100Present in over

    countries

    11foreignsubsidiaries

    90importers

  • Successful products andsolutions

    Machine builders(OEM)

    Pumping, irrigationand piping

    Power factorcorrection

    Lifting systems

    Motor protection circuitbreakers

    Contactors

    Motor protection relays

    Electromechanical starters

    Soft starters

    AC motor drives

    Pushbuttons and selectorswitches

    Signal towers and beacons

    Limit, micro and footswitches

    Rotary cam switches

    Switch disconnectors

    Fuse holders

    Miniature and residualcircuit breakers

    Surge protection devices

    Time relays

    Protection relays

    Micro PLCs

    Switching power supplies

    Metering instruments andCTs

    Motor protection circuitbreakers

    Contactors

    Motor protection relays

    Electromechanical starters

    Soft starters

    AC motor drives

    Pushbuttons and selectorswitches

    Signal towers and beacons

    Rotary cam switches

    Switch disconnectors

    Fuse holders

    Miniature and residualcircuit breakers

    Time relays

    Protection relays

    Level control relays andelectrodes

    Micro PLCs

    Contactors

    Switch disconnectors

    Fuse holders

    Miniature and residualcircuit breakers

    Metering instruments andCTs

    Automatic power factorcontrollers

    Thyristor modules

    Setup and remote controlsoftware

    Motor protection circuitbreakers

    Contactors

    Motor protection relays

    Electromechanical starters

    Soft starters

    AC motor drives

    Pushbuttons and selectorswitches

    Signal towers and beacons

    Limit, micro and footswitches

    Switch disconnectors

    Fuse holders

    Miniature and residualcircuit breakers

    Time relays

    Protection relays

    Micro PLCs

    Switching power supplies

  • Photovoltaicapplications

    Generating sets Electric powerdistribution

    Energymanagement

    Contactors

    Switch disconnectors

    Fuse holders

    Fuses

    Miniature and residualcircuit breakers

    Surge protection devices

    Switching power supplies

    Metering instruments andCTs

    Interface protection relays

    Software and applications

    Motor protection circuitbreakers

    Contactors

    Pushbuttons and selectorswitches

    Rotary cam switches

    Changeover switches

    Fuse holders

    Miniature and residualcircuit breakers

    Surge protection devices

    Earth leakage relays

    Protection relays

    Automatic battery chargers

    Automatic transfer switch controllers

    Metering instruments andCTs

    Engine and generatorcontrollers

    Software and applications

    Motor protection circuitbreakers

    Switch disconnectors

    Miniature and residualcircuit breakers

    Surge protection devices

    Modular contactors

    Earth leakage relays

    Time relays

    Protection relays

    Micro PLCs

    Switching power supplies

    Automatic battery chargers

    Metering instruments andCTs

    Automatic transfer switchcontrollers

    Software and applications

    Soft starters

    AC motor drives

    Micro PLCs

    Metering instruments andCTs

    Automatic power factorcontrollers

    Automatic transfer switchcontrollers

    Engine and generatorcontrollers

    Software and applications

  • Quality and certifications

    LOVATO Electric S.p.A. was among the first Italiancompanies, in 1992, to hold the quality managementsystem certification, in compliance with the standard

    ISO 14001

    also maintaining an EnvironmentManagement System, certified

    according to the standard

    ISO 9001

  • Our laboratory is authorised to conducttype testing for the emission of certification

    850m2 It covers an area of

    subdivided in diverse specialised sectors Tests conducted according to

    Main tests:- Making and breaking capacities- Short-circuit with comparator system- Temperature rise- Thermal protection functionality - Verification of dielectric properties- Verification of terminals mechanical properties- Verification of IK code degree of protection (impact withstand)- Verification of IP code degree of protection (ingress protection

    against water jets)- Shock and vibration withstand- Electrical and mechanical durability- Low current-low voltage contact functionality- Ambient simulation in climatic chamber- Glow-wire ignitability of insulating parts- Immunity to conducted and radiated emission fields - Immunity to surges, fast transients / bursts and electrostatic

    discharges.

    national andinternationalstandards prescriptions

    Qualified laboratoryaccording to standards

    EN ISO/IEC 17025

    ACAE/LOVAG

  • International fairsDubai, Istanbul, Hanover, Moscow and Nuremberg arejust a few of the exhibition events LOVATO Electric yearly take part in.

    Training courses- Basic level for entire production- Advanced level with practical training- Webinars.

    General catalogue- Product information- Overall dimensions- Wiring diagrams- Technical characteristics.

    Other literature- Brochures and pamphlets- Technical instructions.

    2 0 1 42 0 1 5G E N E R A LCATALOGUE

    22

    22-15Software and accessoriespage 22-29

    Expansion modulespage 22-28

    Dimensionspage 22-32

    Wiring diagramspage 22-35

    Technical characteristicspage 22-42

    Metering instruments and current transformersDigital measuring instruments

    Flush mount LCD touch-screen power analyzers,expandable

    General characteristicsDMG 900... expandable digital power analyzers are availablewith a flush-mount housing, 96x96mm/3.8x3.8in size. Thewide graphic touch screen display provides extremely simpleinteracting between the instrument and the user.The high performance of the power analyzers gives veryaccurate measurements and can control energy distributionsystems, to detect and prevent energy problems which couldcompromise quality and supply.The main features include an extensive power supply voltagerange, high measurement accuracy, expandability up to 4plug in expansion modules.There also is available the DMG 900T measurementtransducer which can be used with the DMG 900RD remotedisplay. The DMG 900T, without display, is arranged formounting inside the panel board, on 35mm DIN rail, and is anideal solution for installations where the measurements ofvarious multimeters must be remotely viewed. The DMG 900RD remote display connected to the DMG 900Ttransducer can display the measurements on the panel frontwhile power connections remain inside the panel.Main measurements and functions include: Voltage: phase, line and system values (neutral-earth too) Supply voltage value for the DC supply type only Current: phase values Neutral current calculated and true values Power: apparent, active and reactive phase and total values P.F.: Power Factor per phase and total Cos per phase and total Frequency of measured voltage value Voltage and current asymmetry Total harmonic distortion (THD) of voltage and current Harmonic analysis of voltage and current up to the 63 order HIGH-LOW-AVERAGE value functions for all measurements Maximum demand of power and current values Flow direction of harmonic power values Energy meters for active, reactive, apparent partial and

    total values with programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: pulse counting for water,

    gas, etc. consumption with expansion module only Energy quality analysis to EN 50160 with expansion

    module only.

    Operational characteristics Auxiliary supply voltage range:

    90-484VAC / 93.5-300VDC for DMG 900 and DMG 900T;9-70VDC for DMG 900 D048 and DMG 900T D048

    Voltage measurement range:20-830VAC phase-to-phase10-480VAC phase-neutral

    Use in medium and high-voltage systems with voltagetransformers

    Rated input current: 5A or 1A by CT Current measurement range: 0.01-10A or 0.002-1.2A Current measurement range with CT up to 10,000A Frequency measure range: 45-66Hz / 360-440Hz True RMS measurements for voltage and current values Accuracy:

    Voltage: 0.2% (50-830VAC) Current: 0.2% (0.1-1.1In) Power: 0.5% f.s. Power factor: 0.5% Frequency: 0.05% Active energy: Class 0.5S (IEC/EN 62053-22) Reactive energy: Class 2 (IEC/EN 62053-23)

    Non-volatile memory for data and event (last 100) storage Communication protocol Modbus-RTU, ASCII and

    TCP with communication expansion modules only Programming and remote control by software with

    communication expansion modules only Housing:

    Flush mount 96x96mm/3.8x3.8in for DMG900... and DMG 900RD

    35mm DIN rail (IEC/EN 60715) fixing for DMG 900T IEC protection degree: IP65 on front for DMG 900... and

    DMG 900RD; IP20 at terminals for DMG 900... - DMG 900T.

    EXP10 series expansion modules and accessories See pages 22-28 and 29.

    Certifications and complianceCertifications obtained: GOST and UL Listed, for USA andCanada (File E93601), as Auxiliary Devices-Multimeter for all.Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2,IEC/EN 61000-6-3, UL 508, CSA C22.2 n14.

    Order Description Qty Wtcode per

    pkgn [kg]

    DMG 900 Graphic 128x112 pixel 1 0.566touch-screen LCD, harmonic analysis, 4 channels, auxiliary supply100-440VAC/110-250VDC.Multilanguage: Italian, English, French, Spanishand Portuguese

    DMG 900 L01 Graphic 128x112 pixel 1 0.566touch-screen LCD, harmonic analysis, 4 channels, auxiliary supply100-440VAC/110-250VDC.Multilanguage: English, Czech,Polish, German and Russian

    DMG 900 D048 Graphic 128x112 pixel 1 0.580touch-screen LCD, harmonic analysis, auxiliarysupply 12-24-48VDC

    DMG 900T Measurement transducer, 1 0.570harmonic analysis, 4 channels, auxiliary supply 100-440VAC/110-250VDC, RS232/RS485 port

    DMG 900T D048 Measurement transducer, 1 0.590harmonic analysis, 4 channels, auxiliary supply 12-24-48VDC, RS232/RS485 port

    Remote display for DMG 900T...DMG 900RD Graphic 128x112 pixel touch 1 0.396

    screen LCD, with 3m/9.8ft long connecting cable

    DMG 900T...

    DMG 900RD

    DMG 900...

    Order DescriptioncodeDMG 900 and DMG 900 T EXPANSION MODULES.Inputs and outputs.EXP10 00 4 digital opto-isolated inputsEXP10 01 4 static opto-isolated outputsEXP10 02 2 digital inputs and 2 static outputs, opto-isolatedEXP10 03 2 relay outputs rated 5A 250VACEXP10 04 2 analog opto-isolated inputs 0/4-20mA or

    PT100 or 0-10V or 0...5VEXP10 05 2 analog opto-isolated outputs 0/4-20mA or

    0-10V or 0...5VCommunication ports.EXP10 10 Opto-isolated USB interfaceEXP10 11 Opto-isolated RS232 interfaceEXP10 12 Opto-isolated RS485 interfaceEXP10 13 Opto-isolated Ethernet interface with Web

    server functionEXP10 14 Opto-isolated Profibus-DP interface EXP10 15 GPRS/GSM modemEXP10 30 Data storage, clock-calendar (RTC) with backup

    battery for data loggingEXP10 31 Data storage, with Energy Quality (EN 50160),

    clock-calendar (RTC) with backup battery fordata logging

    EXP 10...

    LOW ACTUATOR PROFILEThe external actuator bezel has a low profileand reduced front thickness.

    CUSTOMISING CAPABILITY To simplify stock management, the new series allows

    quick replacement of the actuator cap or lens of springreturn types since these are also sold as accessories.

    QUICK AND EASY ACTUATORINSTALLATION

    - Actuator fixing on the mountingsurface, through a 22mm/0.87indrilled hole, is obtained using itsthreaded ring, easily rotated byhand or by socket spanner/wrench.

    - There is an anti-rotation fastener,duly sized to avoid actuator rotationon the mounting surface and to givean orientation reference point forusers during panel installation andduring contact fitting on theactuator.

    - This anti-rotation fastener collapsesinside the gasket to allow fitting alsowhen drilled holes are round withoutreference index.

    - The sealing gasket for the actuatormounting surface has a grippingaction (suction effect) offering asurface prefixing property.

    REDUCED DIMENSIONS ANDINTERAXIS

    - The new series provides a minimum30x40mm (1.18x1.57in) pitchbetween two actuators on amounting surface.

    - Minimum pitch between drilled holesfor double and triple touch actuatorsis 30x55mm (1.18x1.97in).

    - Total depth, from the externalmounting surface to the end of the first contact element is merely43mm (1.69in).

    CONTACT ELEMENTS

    - Miniaturised size - High electric conductivity - 5V 1mA- Up to 9 contact elements can be

    installed, 3 rows of 3 elements- Screw or faston termination - Contact operation: double breaking

    action, direct opening operation andself cleaning.

    HIGH-LUMINOSITY LEDINTEGRATED LAMP HOLDERS

    - Miniaturised size - Long electrical life: 100,000h- Over-voltage protection - Withstand to vibrations - Protection against stray currents in

    wiring- Flickering phenomenon reduction- Steady and flashing light versions - Supply voltages:

    18-30VAC/DC 85-140VAC 185-265VAC.

    Click!

    43mm (1.69in)

    10mm

    7

    - The mounting adapter and theactuators each have clearly visiblereference indications making thesnap-on fitting between the twoeasy and intuitive.

    - Electrical contacts and LED lampholders are snapped onto themounting adapter.

    30(1.18)

    30(1.18)

    40 (1

    .57

    )

    40 (1

    .57

    )

    22.5(0.88)

    QUALITY TOUCH!

    Click!

    7-2

    Pushbuttons and selector switches22mm series

    HIGH DEGREE OF PROTECTIONIEC IP66, IP67, IP69K and UL TYPE 4XThe actuators have been tested to ensure a degree ofprotetection per IEC IP66, IP67, IP69K and UL type 4X,appropriate for use even in extreme ambient conditions.

  • Social NetworksYoutube Channel

    - New products- Videos- Online news- Fairs- Events and training sessions- Contacts

    - Download: General catalogue Leaflets and technical

    instructions Software upgrade Drivers and utilities 2D / 3D CAD drawings.

    LovatoElectric.com

  • SM1A Thermal trip adjustment ranges 9-32A

    (5 choices) IEC breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer

    switchboards, minimum 58mm/2.3in deep.

    Page 1-2 Page 1-2

    SM1B Thermal trip adjustment ranges 0.1-32A

    (15 choices) IEC breaking capacity Icu at 400V: 100kA (ranges 0.1-10A) 25kA (ranges 9-32A) Suitable for mounting in consumer

    switchboards, minimum 58mm/2.3in deep.

    SM1C Same characteristics per SM1B breaker Suitable for mounting in consumer

    switchboards, minimum 45mm/1.8in deep.

    Page 1-2

    SM2A Thermal trip adjustment ranges 28-50A

    (3 choices) IEC breaking capacity Icu at 400V: 50kA.

    Page 1-3

    SM3A Thermal trip adjustment ranges 45-100A

    (4 choices) IEC breaking capacity Icu at 400V: 50kA.

    Page 1-3

    LMS25 Thermal trip adjustment ranges 0.1-25A

    (13 choices) IEC breaking capacity Icu at 400V: 100kA (ranges 0.1-6.3A) 6kA (ranges 6.3-10A) 4kA (ranges 10-25A) Suitable for mounting in consumer

    switchboards, minimum 45mm/1.8in deep.

    Page 1-10

  • MOTOR PROTECTION CIRCUIT BREAKERS 1

    Short-circuit tripping indicator, standard suppliedon all circuit breakers, type SM1.Reset the indicator, as illustrated, to restore thebreaker.

    SEC. - PAGEMotor protection circuit breakers

    Breakers SM1A, SM1B and SM1C ...................................................................................................................................... 1 - 2Breakers SM2A and SM3A ................................................................................................................................................. 1 - 3Add-on blocks and accessories for SM1A, SM1B and SM1C ............................................................................................... 1 - 4Add-on blocks and accessories for SM2A and SM3A .......................................................................................................... 1 - 8Starters LMS25 ................................................................................................................................................................. 1 - 10Add-on blocks and accessories for LMS25 ......................................................................................................................... 1 - 11

    Dimensions ................................................................................................................. 1 - 12Wiring diagrams ........................................................................................................... 1 - 15Technical characteristics ................................................................................................. 1 - 16

    Wide adjustment range 0.1 to 100AIEC breaking capacity Icu 50kA(400V) up to 100ASuitable for isolationComprehensive line of accessoriesFront mount contactsAutomatic trip indicatorsHigh reliability and accuracy oftripping.

    MO

    TO

    RC

    ON

    TR

    OL

    AN

    DP

    RO

    TE

    CT

    ION

  • 1-2Add-on blocks/Accessories pages 1-4 to 7

    Dimensionspages 1-12 and 13

    Wiring diagrams pages 1-15 and 16

    Technical characteristics pages 1-16 and 17

    Motor protection circuit breakersWith thermal and magnetic trip releases

    1General characteristicsThe SM1 is a modern series of circuit breakers withthermal and magnetic trip releases and high breakingcapacity. Motor control and protection, up to 15kW at400V/20HP 480V/30HP 600V, are possible by choosingthe suitable adjustment range, 0.1 to 32A.A magnetic trip indicator integrated on the SM1 breakersavoids dangerous closing operations during short-circuitconditions, previously disconnected by the breaker.The SM1 types are suitable for isolation according toIEC/EN 60947 standards. Their high breaking capacity consents to excludeprotection fuses on the majority of the installations.

    Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Maximum rated current: 32A Number of adjustment ranges: SM1A: 5 (9 to 32A) SM1B: 15 (0.1 to 32A) SM1C: 15 (0.1 to 32A) IEC breaking capacity: see page 1-17 Power dissipation: 2.2-9.7W Magnetic tripping: 12In max IEC thermal tripping class: 10A Phase failure / Single phase sensitive Mechanical life: 100,000 cycles Electrical life: 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) Mounting position: Any IEC utilisation category: A IEC degree of protection: IP20.

    Certifications and complianceCertifications obtained: EAC; and UL Listed, for USA andCanada (cULus - File E93602); CCC for some SM1B typesonly (consult Customer Service for details; see contactdetails on inside front cover). See UL/CSA details under NOTE on the bottom left side.Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14.

    Motor protection circuitbreakers SM1 up to 32A

    The SM1C version permits mounting in enclosures and modularconsumer switchboards with minimum depth of at least 45mm betweenthe DIN rail and the opening. See page 1-12 for exact breaker dimensions.

    No front-mount auxiliary contacts 11 SMX11... can be used.

    Order Thermal Short circuit Qty Wt code trip breaking per adjustment capacity pkg range at 400V Icu Ics [A] [kA] [kA] n [kg] IEC breaking capacity Icu 50kA at 400V. 11 SM1A 40 9-14 50 25 5 0.352 11 SM1A 44 13-18 50 25 5 0.352 11 SM1A 48 17-23 50 25 5 0.352 11 SM1A 52 20-25 50 25 5 0.352 11 SM1A 56 24-32 50 25 5 0.352 IEC breaking capacity Icu 100kA (0.1-10A) / 25kA (9-32A) at 400V. 11 SM1B 00 0.1-0.16 100 100 5 0.278 11 SM1B 04 0.16-0.25 100 100 5 0.278 11 SM1B 08 0.25-0.4 100 100 5 0.278 11 SM1B 12 0.4-0.63 100 100 5 0.278 11 SM1B 16 0.63-1 100 100 5 0.278 11 SM1B 20 1-1.6 100 100 5 0.278 11 SM1B 24 1.6-2.5 100 100 5 0.352 11 SM1B 28 2.5-4 100 100 5 0.352 11 SM1B 32 4-6.5 100 100 5 0.352 11 SM1B 36 6.3-10 100 100 5 0.352 11 SM1B 40 9-14 25 12.5 5 0.352 11 SM1B 44 13-18 25 12.5 5 0.352 11 SM1B 48 17-23 25 12.5 5 0.352 11 SM1B 52 20-25 25 12.5 5 0.352 11 SM1B 56 24-32 25 12.5 5 0.352 IEC breaking capacity Icu100kA (0.1-10A) / 25kA (9-32A) at 400V. Suitable for mounting in modular consumer switchboards . 11 SM1C 00 0.1-0.16 100 100 5 0.278 11 SM1C 04 0.16-0.25 100 100 5 0.278 11 SM1C 08 0.25-0.4 100 100 5 0.278 11 SM1C 12 0.4-0.63 100 100 5 0.278 11 SM1C 16 0.63-1 100 100 5 0.278 11 SM1C 20 1-1.6 100 100 5 0.352 11 SM1C 24 1.6-2.5 100 100 5 0.352 11 SM1C 28 2.5-4 100 100 5 0.352 11 SM1C 32 4-6.5 100 100 5 0.352 11 SM1C 36 6.3-10 100 100 5 0.352 11 SM1C 40 9-14 25 12.5 5 0.352 11 SM1C 44 13-18 25 12.5 5 0.352 11 SM1C 48 17-23 25 12.5 5 0.352 11 SM1C 52 20-25 25 12.5 5 0.352 11 SM1C 56 24-32 25 12.5 5 0.352

    11 SM1B...

    11 SM1C...

    11 SM1A...

    Thermal General useType adjustment range 1 Phase [HP] 3 Phase [HP] at 600V (FLA)[A] 120V 230V 200-208V 230V 480V 600V [A]

    SM100 0.1-0.16 0.16SM104 0.16-0.25 0.25SM108 0.25-0.4 0.4SM112 0.4-0.63 0.63SM116 0.63-1 1/2 1/2 1SM120 1-1.6 1/10 3/4 1 1.6SM124 1.6-2.5 1/6 1/2 1/2 1 11/2 2.5SM128 2.5-4 1/8 1/3 3/4 3/4 2 3 4SM132 4-6.5 1/4 1/2 11/2 11/2 3 5 6.5SM136 6.3-10 1/2 11/2 2 3 5 71/2 10SM140 9-14 3/4 2 3 3 10 10 14SM144 13-18 1 3 5 5 10 15 18SM148 17-23 11/2 3 5 71/2 15 20 23SM152 20-25 2 3 5 71/2 15 20 25SM156 24-32 2 5 10 10 20 30 32

    Maximum UL/CSA horsepower rating

    NOTE: When more than one breaker are mounted, side by side, withoutleaving space between each to consent free air circulation on thebreaker sides, and have simultaneous operation, the thermal tripadjuster must be positioned at a value 15% higher than the rated motorcurrent.

    T E S T

    ovato

    1Nm/9lbinmax

    2.3Nm/20lbinmax

    1Nm/9lbinmaxTESTLovat

    oL

    NOTE: All data mentioned is valid for 11SM1A, 11SM1Band 11SM1C types; UL Listed in USA and Canada as manual motor controller suitable as motordisconnect, delivering not more than 5000rms symmetrical amperes, 600VAC, and use with class Jfuses only. Trip current is 120%.

    The appropriate thermal trip range of thecontroller should be selected on the basis of themotor nameplate full-load current since thehorsepower ratings given are for indication andreference purposes only.

    Single-phase horsepower ratings are based onwiring the three poles in series; see wiring scheme on page 1-15.

  • 1-3Add-on blocks/Accessories pages 1-8 and 9

    Dimensionspage 1-14

    Wiring diagrams pages 1-15 and 16

    Technical characteristics pages 1-16 and 17

    Motor protection circuit breakersWith thermal and magnetic trip releases

    1General characteristicsThe SM2A and SM3A types are circuit breakers with awide adjustment range, 28 to 100A, in only two framesizes enabling motor control and protection up to 45kWat 400V/75HP 480V/100HP 600V. A magnetic trip indicator and padlockable operatinghandle are integrated on the SM2A and SM3A breakers.Both are suitable for isolation according to IEC/EN 60947standards. Their high breaking capacity consents to excludeprotection fuses on the majority of the installations.

    Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Maximum rated current: 50A (SM2A) and 100A (SM3A) Number of adjustment ranges:

    SM2A: 3 (28 to 50A) SM3A: 4 (45 to 100A)

    IEC breaking capacity: See table on page 1-17 Power dissipation:

    SM2A: 7.1-20W SM3A: 10-38W

    Magnetic tripping: 13In max IEC thermal tripping class: 10 Phase failure / Single phase sensitive Life (cycles): Mechanical Electrical (Ie AC3)

    SM2A 50,000 25,000 SM3A 50,000 25,000

    Mounting: SM2A - Screw fixing or on 35mm DIN rail (IEC/EN 60715) SM3A - Screw fixing or on DIN rail 35mm (IEC/EN 60715) or 75mm (IEC/EN 60715) Mounting position: Any IEC utilisation category: A IEC degree of protection: IP00.

    Certifications and complianceCertifications obtained: EAC; UL Listed, for USA andCanada (cULus - File E155982); CSA certified (File 73212).See UL/CSA details under NOTE below bottom table.Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14.

    NOTE: When more than one breaker are mounted, side by side, withoutleaving space between each to consent free air circulation on thebreaker sides, and have simultaneous operation, the thermal tripadjuster must be positioned at a value 15% greater than the ratedmotor current.

    Order Thermal Short circuit Qty Wt code trip breaking per adjustment capacity (IEC) pkg range at 400V Icu Ics [A] [kA] [kA] n [kg] IEC breaking capacity Icu 50kA at 400V. 11 SM2A 68 28-40 50 25 1 1.040 11 SM2A 72 36-45 50 25 1 1.040 11 SM2A 76 40-50 50 25 1 1.040 IEC breaking capacity Icu 50kA at 400V. 11 SM3A 84 45-63 50 25 1 2.266 11 SM3A 88 57-75 50 25 1 2.266 11 SM3A 92 70-90 50 25 1 2.266 11 SM3A 96 80-100 50 25 1 2.266

    Motor protection circuitbreakers SM2A - SM3Aup to 100A

    11 SM2A...

    11 SM3A...

    Thermal 1 Phase [HP] FLA MaxType adjustment range (not mentioned 3 Phase [HP] max at Fuse /by UL/CSA) 600V CB

    [A] 120V 230V 200-208V 230V 480V 600V [A] [A]SM2A 68 28-40A 3 71/2 15 15 30 40 40 150SM2A 72 36-45A 5 71/2 15 15 30 40 45 175SM2A 76 40-50A 5 10 15 20 40 50 50 200SM3A 84 45-63A 5 15 20 25 50 60 63 250SM3A 88 57-75A 71/2 15 25 25 60 75 75 300SM3A 92 70-90A 10 20 30 30 75 100 90 350SM3A 96 80-100A 10 20 40 40 75 100 100 400

    NOTE:For SM2A types: UL Listed for USA and Canada and CSA certified as manual motor controller, short circuit 65kA 480V; 25kA 600V; max fuse / CB (see table).Suitable for group installation. CSA: Maximum fuse / CB 350A. UL: SPCD according NEC; suitable as motor disconnect 600Y/347V. Suitable as tap conductor protection in group installation 65kA 480Y/277V, 25kA 600Y/347V. Maximum fuse / CB 500A. Trip amps 125%.For SM3A84 and SM3A88 types: UL Listed for USA and Canada and CSA certified as manual motor controller, short circuit 65kA 480V; 30kA 600V; max fuse /CB (see table). Suitable for group installation. CSA: Maximum fuse / CB 500A. UL: SPCD according NEC; suitable as motor disconnect 600Y/347V. Suitable as tap conductor protection in group installation 65kA 480Y/277V, 30kA 600Y/347V. Maximum fuse / CB 1200A. Trip amps 125% .For SM3A92 and SM3A96 types: UL Listed for USA and Canada and CSA certified as manual motor controller, short circuit 65kA 480V; 10kA 600V; max fuse /CB (see table). Suitable for group installation. CSA: Maximum fuse / CB 500A. UL: SPCD according NEC; suitable as motor disconnect 480Y/277V. Suitable as tap conductor protection in group installation 65kA 480Y/277V. Maximum fuse / CB 1200A. Trip amps 125%.

    The appropriate thermal trip range of the controller should be selected on the basis of the motor nameplate full-load current since the horsepower ratingsgiven are for indication and reference purposes only.

    Single-phase horsepower ratings are based on wiring the three poles in series; see wiring scheme on page 1-15.

    Maximum UL/CSA horsepower rating

  • 1-4Dimensionspages 1-12 and 13

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM1 types

    1General and operational characteristicsADD-ON AUXILIARY BLOCKS Snap on to the front or the right side of the breaker Maximum combination: 3 SMX... blocks with

    6 auxiliary contacts in total of which 2 on front (SM1Cexcluded) and 4 on the side (2 normal contacts and 2 indicators)

    IEC conventional free air thermal current Ith: 6A (2.5A for SMX11...)

    IEC rated insulation voltage Ui: 690V (250V forSMX11...)

    UL/CSA and IEC/EN 60947-5-1 designation: C600 Q600 (C300 R300 for SMX11...)

    Maximum tightening torque: 1Nm/9lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.75-2.5 mm2 or 18/14 AWG Width of side-mount auxiliary contacts equal to 0.5

    standard DIN 46880 module.

    UNDERVOLTAGE TRIP RELEASE Connectable to the left side of the breaker Consumption in-rush/holding: 12/3.5VA Drop-out voltage: 0.35-0.7Us Pick-up voltage: 0.85-1.1Us Maximum tightening torque: 1Nm/9lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.75-2.5mm2 or 18/14 AWG.

    SHUNT TRIP RELEASE Connectable to the left side of the breaker In-rush consumption: 20VA Operating limits: 0.7-1.1Us Maximum tightening torque: 1Nm/9lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.75-2.5mm2 or 18/14 AWG.

    TERMINAL BLOCK FOR BUSBAR SUPPLY Imax 63A Maximum tightening torque: 2.3Nm/20lbin Conductor cross section minimum-maximum:

    4-25mm2 or 10/4 AWG.

    THREE-PHASE CONNECTION BUSBAR Imax 63A SMX90 3... 45mm/1.77 spacing to reduce the width

    to the minimum SMX90 4... 54mm/2.13 spacing to consent to fit one

    side-mount auxiliary contact block on the breaker.

    Certifications and complianceCertifications obtained: EAC for all; UL Listed, for USAand Canada (cULus - File E93602), under motorcontrollers, for auxiliary contacts, releases andpadlockable attachment of operating lever; CCC forSMX12... and SMX13 11 auxiliary contacts.Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL508, CSA C22.2 n 14.

    Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. 11 SMX11 20 Front mount 2NO 10 0.013 11 SMX11 11 Front mount 1NO+1NC 10 0.013 11 SMX12 11 Side mount 1NO+1NC 10 0.045 11 SMX12 02 Side mount 2NC 10 0.045 11 SMX12 20 Side mount 2NO 10 0.045 11 SMX13 11 Side-mount indicator 10 0.045 contacts for thermal and magnetic tripping 1NO+1NC Undervoltage trip releases. 11 SMX14 BC 110VAC 50/60Hz 5 0.125 11 SMX14 CL 230VAC 50/60Hz 5 0.125 11 SMX14 EA 400VAC 50/60Hz 5 0.125 11 SMX15 CL 230VAC 50/60Hz 5 0.140 with early-make contacts 11 SMX15 EA 400VAC 50/60Hz 5 0.140 with early-make contacts Shunt trip releases. 11 SMX16 AF 24VAC 50/60Hz 5 0.124 11 SMX16 BC 110VAC 50/60Hz 5 0.124 11 SMX16 CL 230VAC 50/60Hz 5 0.124 11 SMX16 EA 400VAC 50/60Hz 5 0.124 Padlockable attachment for operating lever. 11 SMX18 10 3 padlocks max 5mm 1 0.049 Adjuster sealing kit. 11 SMX18 12 For all types 1 0.006 Padlockable door coupling handle. 11 SMX18 14 3 padlocks maximum 1 0.720 IP65. Red/yellow 11 SMX18 15 3 padlocks maximum 1 0.760 IP65. Black Terminal block for busbar supply. 11 SMX90 30 For all types 10 0.048 Safety cover. 11 SMX90 31 For unused busbar terminals 10 0.005 Three-phase connection busbars 45mm/1.77 spacing. 11 SMX90 32 For 2 breakers without 10 0.027 side-mount contacts 11 SMX90 33 For 3 breakers without 10 0.050 side-mount contacts 11 SMX90 34 For 4 breakers without 10 0.071 side-mount contacts 11 SMX90 35 For 5 breakers without 10 0.092 side-mount contacts Three-phase connection busbars 54mm/2.13 spacing. 11 SMX90 42 For 2 breakers complete with 10 0.031 side-mount contacts 11 SMX90 43 For 3 breakers complete with 10 0.056 side-mount contacts 11 SMX90 44 For 4 breakers complete with 10 0.081 side-mount contacts 11 SMX90 45 For 5 breakers complete with 10 0.081 side-mount contacts Not suitable for fixing on SM1C types. Tripping is indicated by flag indicator on front.

    11 SMX11... 11 SMX12...

    11 SMX13 11

    11 SMX15... 11 SMX16...

    11 SMX90 3...11 SMX90 4...

    11 SMX90 30 11 SMX90 31

    11 SMX14...

    11 SMX18 10

  • 1-5Dimensionspages 1-12 and 13

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM1 types

    1General and operational characteristicsSM1 - CONTACTOR CONNECTIONThe SMX90 03, SMX31... and SMX32 41 rigidconnections electrically and mechanically fasten the breaker together with the contactor forming a single-unit starter for quick installation on 35mm DIN rail (IEC/EN 60715).

    STARTER ASSEMBLY ADAPTER PLATESThe elements consent to preassemble starters and toform trim and compact single-unit equipment for quickand easy installation.The starter adapter plates install on 35mm DIN rail (IEC/EN 60715).

    SURFACE MOUNT ENCLOSURE Top or bottom entry: PG16 threaded knockouts for SMX17 10 22.5mm/0.88 knockouts for SMX17 11 Rear entry: 22.5mm/0.88 knockouts Holds a SM1 breaker equipped with one side-mount

    contact block, one front-mount block (except forSM1C) and either one shunt or undervoltage release

    Earth/ground terminal included Operating temperature: -5...+40C Storage temperature: -50...+80C.

    FLUSH MOUNT ENCLOSURE Use with breaker, complete with 1 front-mount (except

    for SM1C) and 1 side-mount blocks and one shunt orundervoltage release

    Earth/ground terminal included 103x144mm/4.05x5.67 cutout Operating temperature: -5...+40C Storage temperature: -50...+80C.

    ENCLOSURE ACCESSORIESPADLOCKABLE ROTARY ACTUATOR: Suitable for SMX17 10 or SMX17 20 type only Raises the degree of protection of the enclosure

    to IEC IP65 3 padlocks maximum.

    ACTUATOR WITH EMERGENCY PUSH-BUTTON: Suitable for SMX17 11 only Raises the degree of protection of the enclosure to

    IEC IP65.

    Certifications and complianceCertifications obtained: EAC for all SMX... types and pilotlights; UL Listed for USA and Canada (cULus - File E93602), under motor controllers, for SMX90 03,SMX31 41 and SMX32 41 connections.Compliant with standards: IEC/EN 60947-1, UL508, CSA C22.2 n 14.

    Order code Characteristics Qty Wt per pkg n [kg] Rigid SM1 breaker-contactor connections. 11 SMX90 03 For SM1 breaker with BG 10 0.025 mini-contactor. SMX31 41 For SM1 breaker with 10 0.044 BF09A-BF25A contactor. Complete with cover SMX31 42 For SM1 breaker with 10 0.046 BF09D-BF25D and BF09L-BF25L contactor. Complete with cover SMX32 41 For SM1 breaker with 10 0.050 BF26A-BF38A contactor. Complete with cover Adapter plates. 11 SMX90 10 Adapter plate for 1 0.058 direct-on-line starter (SM1 breaker and BG or BF09A-BF38A contactors) 11 SMX90 12 Adapter plate for reversing 1 0.095 contactor assembly (SM1 breaker and BG or BF09A-BF38A contactors) 11 SMX90 14 Adapter plate for star-delta 1 0.118 starter (SM1 breaker and 45mm/1.77 wide contactors BF09A-BF38A) 11 SMX90 18 35mm DIN rail 1 0.025 (IEC/EN 60715) for cable bypass of contactor used with SMX90 14 plate 11 SMX90 19 35mm DIN rail extension 1 0.025 Surface mount enclosures. 11 SMX17 10 IP40. 100mm/4 wide 1 0.404 11 SMX17 11 IP40. 85mm/3.3 wide 1 0.358 Flush mount enclosure. 11 SMX17 20 IP40. 122mm/4.8 wide, 1 0.341 103x144mm/4.05x5.67 cutout ACCESSORIES FOR ENCLOSURES. Padlockable rotary actuator. 11 SMX17 30 IP65. Grey-black. 1 0.110 For SMX17 10 and SMX17 20 enclosures 11 SMX17 35 IP65. Red-yellow. 1 0.142 For SMX17 10 and SMX17 20 enclosures Actuator with emergency stop button. 11 SMX17 40 IP65. For SMX17 11 10 0.174 enclosure IP65 membrane complete with rim. 11 SMX17 45 For SMX17 11 enclosure 10 0.035 Neutral connection. 11 SMX17 50 For SMX17 10 and 10 0.026 SMX17 20 enclosures only Pilot light. 23 NEONVV Green 10 0.006 23 NEONRV Red 10 0.006 Marking elements. BFX30 Blank label for writing 50 0.002 To obtain IP65 degree of protection, mount the 11 SMX17 45 membrane. The device obtained with this actuator is not suitable for isolation per

    IEC/EN 60947-2 standards. Complete with required voltage. Available voltages: AC 50/60Hz 24/110/220-240 (indicate 220)/380-415 (indicate 380) VAC.

    11 SMX17 40

    11 SMX17 10 11 SMX17 11

    11 SMX17 20

    11 SMX17 35

    11 SMX17 45

    SMX31 41SMX31 42SMX32 41

    11 SMX90 10 11 SMX90 12

    11 SMX90 14

    11 SMX90 03

  • 1-6Dimensionspages 1-12 and 13

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM1 types

    1 CombinationsFront-mount contacts Side-mount contactsUndervoltage trip releaseShunt trip release

    Side-mount contactsUndervoltage trip release with auxiliarycontacts

    Not suitable for use with SM1C type. Only one add-on block can be fixed on the left side of the breaker. One of the following combinations can be mounted on the right side of the breaker: One each of SMX13 11 and SMX12... or one only SMX13 11 or one only SMX12 ...

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    TEST

    Three-phase connection busbars

    Three-phase connectionbusbar, 54mm/2.13spacing (breakers withadd-on blocks)

    Three-phase connection busbar,45mm/1.77 spacing (breakers without add-on blocks)

    SMX90 32SMX90 33

    SMX90 34

    SMX90 30 SMX90 35

    SMX90 31

    SMX90 42

    SMX90 43

    SMX90 44

    SMX90 30

    SMX90 45

    SMX90 31

    TEST

    SMX11...

    SMX14...SMX16...

    SMX1311 SMX12...

    SMX15

    SMX1311 SMX12...

  • 1-7Dimensionspages 1-12 and 13

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM1 types

    1CombinationsRigid breaker-contactor connection and protection cover

    TEST

    TEST

    SMX31 41SMX31 42

    TEST

    SMX32 41

    SM1...

    SMX90 03

    SM1...SM1...

    BG...BF09-BF25

    BF26A-BF38A

    Surface mount enclosure SMX17 10 or SMX17 11

    Flush mount enclosure SMX17 20

    Padlockable attachmentfor operating lever

    Adjuster sealing kit Padlockable door coupling handle

    SMX18 10

    TEST

    SMX14...

    SMX16...

    SMX15...

    SMX13 11

    SMX12...

    SMX11...

    SMX17 11

    SMX17 40

    Surface mount enclosure SMX17 11 complete withemergency stop button SMX17 40.

    SMX18 12

    SMX18 14SMX18 15

    For BF09A-BF25A contactors. For BF09D-BF25D and BF09L-BF25L contactors. One only add-on block can be mounted on each

    side of the breaker.

  • 1-8Dimensionspage 1-14

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM2A and SM3A types

    1General and operational characteristicsADD-ON AUXILIARY BLOCKS Insert on the top front or snap on the left side of the

    breaker Maximum combination: 4 SMX... blocks with

    8 auxiliary contacts in total of which 2 on front and 6on the sides (2 normal contacts and 4 indicators)

    IEC conventional free air thermal current Ith: 10A (2.5A for SMX21 11)

    IEC rated insulation voltage Ui: 690V (250V for SMX20... and SMX21...)

    UL/CSA and IEC/EN 60947-5-1 designation: A600 Q300 (C300 R300 for SMX20... and SMX21...)

    Maximum tightening torque: 1.2Nm/10.3lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.5-2.5mm2 or 18/14 AWG.

    UNDERVOLTAGE TRIP RELEASE Snap on to the right side of the breaker Consumption inrush/holding: 20.2/7.2 VA; 13/2.4 W Drop-out voltage: 0.35-0.7Us Pick-up voltage: 0.85-1.1Us Maximum tightening torque: 1.2Nm/10.3lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.5-2.5mm2 or 18/14 AWG.

    SHUNT TRIP RELEASE Snap on to the right side of the breaker In-rush consumption: 20.2VA; 13W Operating voltage: 0.7-1.1Us Maximum tightening torque: 1.2Nm/10.3lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.5-2.5mm2 or 18/14 AWG.

    Certifications and complianceCertifications obtained: EAC for all; UL Listed, for USAand Canada (cULus - File E93601), and CSA Certified (File 703212), as Auxiliary Devices, for auxiliary contactsand releases.Compliant with standards: IEC/EN 60947-1,IEC/EN 60947-5-1, UL508, CSA C22.2 n 14.

    Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. 11 SMX20 11 Front mount 1 changeover 10 0.016 (SPDT) 11 SMX21 11 Front mount 1NO+1NC 10 0.018 11 SMX22 02 Side mount 2NC 2 0.046 11 SMX22 11 Side mount 1NO+1NC 2 0.046 11 SMX22 20 Side mount 2NO 2 0.046 11 SMX23 11 Side-mount indicator 1 0.092 contacts (1NO+1NC) for thermal trip and (1NO+1NC) for magnetic trip Undervoltage trip releases. 11 SMX24 BC 110VAC 50/60Hz 1 0.136 11 SMX24 CL 230VAC 50/60Hz 1 0.136 11 SMX24 EA 400VAC 50/60Hz 1 0.136 11 SMX25 CL 230VAC (50/60Hz) 1 0.136 with early-make contacts 11 SMX25 EA 400VAC (50/60Hz) 1 0.136 with early-make contacts Shunt trip releases. 11 SMX26 AF 24VAC 50/60Hz 1 0.132 11 SMX26 BC 110VAC 50/60Hz 1 0.132 11 SMX26 CL 230VAC 50/60Hz 1 0.132 11 SMX26 EA 400VAC 50/60Hz 1 0.132 Padlockable door coupling rotary actuator. 11 SMX28 05 IP65. 3 padlocks maximum. 1 0.102 Black colour 11 SMX28 10 IP65. 3 padlocks maximum. 1 0.110 Red-yellow colour See diagram on p. 1-16 for the exact operation.

    11 SMX20 1111 SMX21 11

    11 SMX22...

    11 SMX23 11

    11 SMX24... 11 SMX25... 11 SMX26...

  • 1-9Dimensionspage 1-14

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for SM2A and SM3A types

    1

    Lovato

    L

    Combinations

    Padlockable door coupling rotary actuator SMX28 05 - SMX28 10

    SMX24...SMX25...SMX26...

    SMX20 11SMX21 11

    SMX22...

    SMX23 11

    max. 8 mm max 8mm

    Minimum 75mm distance from door edge(hinge side) for correct operation of doorshaft mechanism. See page 1-14 for moredetails.

  • 1-10Add-on blocks/Accessories pages 1-11

    Dimensionspage 1-15

    Wiring diagrams pages 1-15 and 16

    Technical characteristics pages 1-16 and 17

    Motor protection circuit breakersManual motor starters

    1General characteristicsThe LMS25 manual motor starter is particularly suitable forcontrolling small operating machines.Releases and auxiliary contacts make it also suitable formore complex uses.The LMS25 manual motor starter is suitable for isolationaccording to IEC/EN 60947 standards.Wall and flush-mount enclosures allow to install the LMS25starter in the most disparate environmental conditions (dust,humidity, aggressive environmental agents, etc.).

    Operational characteristics IEC rated insulation voltage Ui: 690V IEC rated impulse withstand voltage: 6kV IEC rated frequency: 50/60Hz Maximum rated current: 25A 13 adjustment ranges 0.1 to 25A IEC breaking capacity: see table on page 1-17 Power dissipation: 2-15W Magnetic tripping: 12In max IEC thermal tripping class: 10 Phase failure / Single phase sensitive Mechanical life: 100,000 cycles Electrical life 25A (IEC AC3): 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) or screw

    fixing Mounting position: Any IEC utilisation category: A IEC degree of protection: IP20.

    Certifications and complianceCertifications obtained: EAC; UL Listed for USA and Canada(cULus - File E155982). See UL/CSA details under NOTEbelow bottom table.Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14.

    NOTE: When more than one breaker are mounted, side by side, withoutleaving space between each to consent free air circulation on thebreaker sides, and have simultaneous operation, the thermal tripadjuster must be positioned at a value 15% greater than the ratedmotor current.

    Order code Thermal Short circuit Qty Wt trip breaking per adjustment capacity (IEC) pkg range at 400V Icu Ics [A] [kA] [kA] n [kg] IEC breaking capacity Icu at 400V: 100kA (0.1-6.3A) / 6kA (6.3-10A) / 4kA (10-25A). 11 LMS25 016T 0.1 - 0.16 100 100 5 0.193 11 LMS25 025T 0.16 - 0.25 100 100 5 0.193 11 LMS25 04T 0.25 - 0.4 100 100 5 0.193 11 LMS25 063T 0.4 - 0.63 100 100 5 0.193 11 LMS25 1T 0.63 - 1 100 100 5 0.193 11 LMS25 1V6T 1 - 1.6 100 100 5 0.193 11 LMS25 2V5T 1.6 - 2.5 100 100 5 0.266 11 LMS25 4T 2.5 - 4 100 100 5 0.266 11 LMS25 6V3T 4 - 6.3 100 100 5 0.266 11 LMS25 10T 6.3 - 10 6 3 5 0.266 11 LMS25 16T 10 - 16 4 2 5 0.266 11 LMS25 20T 16 - 20 4 2 5 0.266 11 LMS25 25T 20 - 25 4 2 5 0.266

    Manual motor starterLMS25 up to 25A

    11 LMS 25...

    Thermal FLA maxType adjustment range 1 Phase [HP] 3 Phase [HP] at 600V[A] 120V 230V 200-208V 230V 480V 600V [A]

    LMS25 016T 0.1-0.16 - - - - - - 0.16LMS25 025T 0.16-0.25 - - - - - - 0.25LMS25 04T 0.25-0.4 - - - - - - 0.4LMS25 063T 0.4-0.63 - - - - - - 0.63

    LMS25 1T 0.63-1 - - - - - 1/2 1LMS25 1V6T 1-1.6 - - - - 3/4 3/4 1.6LMS25 2V5T 1.6-2.5 - 1/6 1/2 1/2 1 11/2 2.5

    LMS25 4T 2.5-4 1/8 1/4 3/4 1 2 3 4LMS25 6V3T 4-6.3 1/4 1/2 11/2 11/2 3 5 6.3LMS25 10T 6.3-10 1/2 1 2 3 5 71/2 10LMS25 16T 10-16 1 2 3 5 10 10 16LMS25 20T 16-20 11/2 3 5 5 10 15 20LMS25 25T 20-25 2 3 5 71/2 15 20 25

    Maximum UL/CSA horsepower rating

    NOTE: UL Listed in USA and Canada as manual motor controller. Fuses only 30A suitable for use on a circuit capable of delivering not more than 5000rms symmetricalamperes, 600VAC. Trip current is 125%.

    The appropriate thermal trip range of the controller should be selected on the basis of the motor nameplate full-load current since the horsepower ratingsgiven are for indication and reference purposes only.

    Single-phase horsepower ratings are based on wiring the three poles in series; see wiring scheme on page 1-15.

  • 1-11Dimensionspage 1-15

    Wiring diagrams pages 1-15 and 16

    Motor protection circuit breakersAdd-on blocks and accessories for LMS25 types

    1 Order code Characteristics Qty Wt per pkg n [kg] Add-on auxiliary contacts. Side mount. 11 LMH 01 1NC 10 0.037 11 LMH 10 1NO 10 0.036 11 LMH 11 1NO + 1NC 10 0.042 11 LMH 20 2NO 10 0.037 Undervoltage trip release. 11 LMU To fit inside starter. 10 0.066 For all types Shunt trip release. 11 LMA To fit inside starter. 10 0.064 For all types Terminal block for busbar supply. 11 SMX90 30 For all types 10 0.048 Safety cover. 11 SMX90 31 For unused busbar 10 0.005 terminals Three-phase connection busbars 45mm/1.77 spacing. 11 SMX90 32 For 2 breakers without 10 0.028 side-mount contacts 11 SMX90 33 For 3 breakers without 10 0.050 side-mount contacts 11 SMX90 34 For 4 breakers without 10 0.071 side-mount contacts 11 SMX90 35 For 5 breakers without 10 0.092 side-mount contacts Three-phase connection busbars 54mm/2.13 spacing. 11 SMX90 42 For 2 breakers complete 10 0.031 with side-mount contacts 11 SMX90 43 For 3 breakers complete 10 0.056 with side-mount contacts 11 SMX90 44 For 4 breakers complete 10 0.081 with side-mount contacts 11 SMX90 45 For 5 breakers complete 10 0.089 with side-mount contacts Surface mount enclosures. 11 LMZ 111 IP55. 80mm/3.15 wide 1 0.260 11 LMZ 112 IP54. 80mm/3.15 wide 1 0.273 Flush mount enclosures. 11 LMZ 113 IP55. 85mm/3.35 wide 1 0.204 11 LMZ 114 IP41. 85mm/3.35 wide 1 0.184 ACCESSORIES FOR ENCLOSURES. Locking mechanism. 11 LMZ 105 3 padlocks maximum 10 0.091 Normal stop button. IP55 protection. 11 LMZ 106 For LMZ 111, LMZ113 1 0.051 and LMZ 114 Neutral connection. 11 LMN PE For all types 10 0.010 Pilot light. 23 NEONVV Green 10 0.006 23 NEONRV Red 10 0.006 Spare rubber membrane complete with rim for enclosures. 11 LMM For LMZ 111, LMZ113 10 0.012 and LMZ 114 enclosures M25 to PG16 entry adapter. 11 LM M25 PG16 For LMZ111 and 10 0.009 LMZ112 enclosures Specify rated voltage. Add suffix 60 if frequency is 60Hz. Available voltages:

    AC 50Hz 24/48/110/220-240 (indicate 220)/380-415 (indicate 380)/ 440-460 (indicate 440)/480 and 575VAC. Complete with required voltage. Available voltages:

    AC 50/60Hz 24/110/220-240 (indicate 220)/380-415 (indicate 380) VAC.

    General and operational characteristicsADD-ON AUXILIARY CONTACTS Connectable to right or left side of starter Maximum combination: 2 LMH... blocks, one on right

    and one on left side of starter (4 auxiliary contacts max intotal)

    IEC rated insulation voltage Ui: 500V IEC conventional free air thermal current Ith: 6A IEC operational current AC15: 3.5A 230V; 2A 400V IEC protection fuse (gL or gG): 6A maximum Maximum tightening torque: 1Nm/9lbin Conductor cross section minimum-maximum

    (1 or 2 wires): 0.75-2.5mm2 or 18/14 AWG Width of the auxiliary contacts LMH... equal to 0.5

    standard DIN 43880 modules.

    UNDERVOLTAGE AND SHUNT TRIP RELEASES Must be fitted inside the motor starter. Undervoltage ShuntRelease range 0.35-0.7Us Operating range 0.85-1.1Us 0.7-1.1UsOn-load factor 100%

    TERMINAL BLOCK FOR BUSBAR SUPPLY Imax 63A Maximum tightening torque: 2.3Nm/20lbin Conductor cross section minimum-maximum:

    4-25mm2 or 10/4 AWG.

    THREE-PHASE CONNECTION BUSBAR Imax 63A SMX90 3... 45mm/1.77 spacing to reduce the width to

    the minimum SMX90 4... 54mm/2.13 spacing to consent to fit one

    side mount auxiliary contact block on the breaker.

    SURFACE MOUNT ENCLOSURE Top or bottom entry: M25 threaded knockouts Rear entry: 15.5mm/0.6 knockouts Up to two auxiliary contact blocks may be mounted Earth/ground terminal included Operating termperature: -5...+40C Storage termperature: -50...+80C.

    FLUSH MOUNT ENCLOSURE Cutout size 70x115mm/2.76x4.53 Up to two auxiliary contact blocks may be mounted Earth/ground terminal included Operating termperature: -5...+40C Storage termperature: -50...+80C.

    ACCESSORIES FOR ENCLOSURESLocking mechanism: Prevents closing operation: 3 padlocks maximum.Emergency stop button: Turn to release Red push-button 35mm/1.38NOTE: Once mounted on the enclosure, these accessoriesraise the degree of protection from IP41 to IP55.

    Certifications and complianceCertifications obtained: EAC for all; UL Listed for USA andCanada (cULus - File E155982), under motor controllers, forauxiliary contacts and trip releases.Compliant with standards: IEC/EN 60947-1,IEC/EN 60947-5-1, UL508, CSA C22.2 n 14.

    11 SMX90 32

    11 SMX90 30

    11 LMZ111 - 11 LMZ112

    11 LMZ113 - 11 LMZ114

    11 LMZ106

    11 LMNPE

    23 NEON...V

    11 LMZ105

    11 LMH... 11 LMU... - 11 LMA...

    11 SMX90 31

  • 1-12

    Motor protection circuit breakersDimensions [mm (in)]

    1Breakers SM1A - SM1Bwith side-mount auxiliary contacts only

    SM1Cwith side-mount auxiliary contacts only

    SM1A - SM1Bwith front and side-mount auxiliary contacts

    SMX14...SMX15...SMX16...

    SMX13 11

    SMX12...

    80.5(3.17)

    18(0.71)

    9(0.35)

    88(3

    .46

    )

    44.5(1.75)

    91(3

    .58

    )35

    .3(1

    .39

    )

    4.8(0.19)

    44.5

    (1.7

    5)

    48.3

    (1.9

    0)

    44.4(1.75)

    72.2(2.84)

    82.5(3.25)

    14.3(0.56)

    SM1 with SMX31 41 connectorand BF09A-BF25A contactors

    SMX31 41

    44.5(1.75)

    184.

    2(7

    .25

    )

    85(3.35)

    SM1 with SMX31 42 connectorand BF09D/L-BF25D/L contactors

    SMX31 42

    44.5(1.75)

    184.

    2(7

    .25

    )

    102.8(4.05)

    Breakers SM1 with SMX90 03 connectorand BG contactors

    SMX90 03

    44.5(1.75)

    160

    (6.3

    0)

    SM1 with SMX32 41 connectorand BF26A-BF38A contactors

    SMX32 41

    44.5(1.75)

    193.

    2(7

    .61

    )

    94(3.70)

    SM1... with SMX18 14 or SMX18 15 door coupling handle

    2.6 (0.10)

    22(0.87)

    104.5(4.11)

    min. 140 / max. 395(min 5.51 / max 15.55)

    SMX18 14SMX18 15

    82.9(3.26)

    110

    (4.3

    3)

    90(3

    .54

    )

    65(2

    .56

    )

    45.1(1.77)

    22.5(0.88)

    61.8

    (2.4

    3)

    23(0.90)

    22(0.87)

    1...4(0.04...0.16)

    3 (0.12)

    36 (1.42)

    36 (1

    .42

    )

    16

    (0.6

    3)

    28...

    32(1

    .10

    ...1.

    26)

    28...32(1.10...1.26)

    SMX18 14SMX18 15

    SMX14...SMX15...SMX16...

    SMX13 11

    SMX12...

    SMX11 11SMX11 20

    80.5(3.17)

    18(0.71)

    9(0.35)

    88(3

    .46

    )

    44.5(1.75)

    91(3

    .58

    )35

    .3(1

    .39

    )

    4.8(0.19)

    44.5

    (1.7

    5)

    55.5

    (2.1

    8)

    44.4(1.75)

    72.2(2.84)

    82.5(3.25)

    23.5(0.92)

    SMX11...

    SMX14...SMX15...SMX16...

    SMX13 11

    SMX12...

    80.5(3.17)

    18(0.71)

    9(0.35)

    88(3

    .46

    )

    44.5(1.75)

    91(3

    .58

    )35

    .3(1

    .39

    )

    4.8(0.19)

    44.5

    (1.7

    5)

    44.4(1.75)

    72.2(2.84)

    82.5(3.25)

  • 1-13

    Motor protection circuit breakersDimensions [mm (in)]

    1

    Enclosures SMX17 10 with SMX17 30 or SMX17 35 handle SMX17 11 with SMX17 40 button

    SMX17 20 with SMX17 30 or SMX17 35 handle

    SMX17 3...

    134.4 (5.29)

    109 (4.29)

    PG16

    100 (3.94)

    42 (1.65)

    19.2

    (0.7

    5)

    170

    (6.6

    9)

    181.

    2 (7

    .13

    )16

    4 (6

    .46

    )

    4.5

    (0.18

    )14

    4 (5

    .67

    )

    103 (4.05)

    SMX17 3...

    94 (3.70) 39.4(1.55)

    14(0.55)

    122 (4.80)

    164

    (6.4

    6)

    SMX17 40

    109 (4.29)173 (6.81)

    170

    (6.6

    9)

    181.

    2 (7

    .13

    )

    85.4 (3.36)

    4.5

    (0.18

    )

    44.1 (1.74)

    23.1

    (0.9

    1)22.5

    (0.88)

    Cutout

    Connection busbars 45mm/1.77 spacing SMX90 32 - SMX90 33 - SMX90 34

    45 (1.77)

    Terminal block forbusbar supplySMX90 30

    1 L1 3 L2 5 L3

    Safety coverSMX90 31

    These elements mounted with SM1... breakers with no auxiliary contacts

    29 (1

    .14

    )

    13.5(0.53) 29

    (1.1

    4)

    13.5(0.53)

    SMX90 31

    SMX90 30

    SMX90 3...

    These elements mounted with SM1... breakers with auxiliary contacts SMX12... or SMX13 11

    SMX90 31

    SMX90 30

    SMX90 4...

    29 (1

    .14

    )

    13.5(0.53) 29

    (1.1

    4)

    13.5(0.53)

    Connection busbars 54mm/2.13 spacing SMX90 42 - SMX90 43 - SMX90 44

    54 (2.13)

    Terminal block forbusbar supplySMX90 30

    1 L1 3 L2 5 L3

    Safety coverSMX90 31

  • 1-14

    Motor protection circuit breakersDimensions [mm (in)]

    1Breakers SM2A with SMX2... contacts

    SMX22...

    SMX23 11

    SMX24...SMX25...SMX26...

    8 (0.31)

    144 (5.67)132 (5.20)127 (5)

    109 (4.29)

    5(1.97)

    121 (4.76)102 (4.01)

    52 (2.05)

    18 (0.71)

    18(0.71)

    55 (2.16)

    30(1.18)

    9(0.35)

    125

    (4.9

    2)

    89 (3

    .50

    )

    45 (1

    .77

    )85

    (3.3

    5)

    130

    (5.1

    2)

    140

    (5.5

    1)

    10 (0.39) 17 (0.67)

    20(0.79)

    SMX22...SMX23 11

    SMX24...SMX25...SMX26...

    SMX20 11SMX21 11

    SMX20 11SMX21 11

    SMX28 05SMX28 10

    22.5

    (0.88

    )

    3.2 (0.12)

    min. 75(2.95)

    132 (5.20)

    5(1.97)

    25(0.98) 1...4 (0.04...0.16)

    min. 55 / max. 130(min 2.16 / max 5.12)

    33(1.30)

    17(0.67)

    24.3

    (0.9

    6)

    SMX24...SMX25...SMX26...

    SMX23 11

    SMX22...

    146 (5.75)

    8 (0.31)

    5(1.97)

    138 (5.43)127 (5)

    77 (3.03)

    138 (5.43)153 (6.02)

    169 (6.65)18 (0.71)

    18(0.71)

    70 (2.75)

    30(1.18)

    9(0.35)

    12(0.47)

    23 (0.90)

    165

    (6.5

    0)

    155

    (6.1

    0)

    89 (3

    .50

    )

    45 (1

    .77

    )11

    6 (4

    .57

    )15

    0 (5

    .90

    )

    SMX24...SMX25...SMX26...

    SMX22...SMX23 11

    SMX20 11SMX21 11 SMX20 11

    SMX21 11

    SMX28 05SMX28 10

    22.5

    (0.88

    )

    3.2 (0.12)

    min. 75(2.95)

    24.3

    (0.9

    6)

    158 (6.22)

    5(1.97)

    33(1.30)

    17(0.67)

    25(0.98) 1...4 (0.04...0.16)

    min. 55 / max. 104(min 2.16 / max 4.09)

    SM2A with SMX28 05 or SMX28 10 door coupling handle

    16(0.63)

    55(2.16)

    140

    (5.5

    1)

    SMX28 05SMX28 10

    22.5

    (0.88

    )

    3.2 (0.12)

    min. 75(2.95)

    24.3

    (0.9

    6)

    132 (5.20)

    5(1.97)

    25(0.98) 1...4 (0.04...0.16)

    33(1.30)

    17(0.67)

    min. 131 / max. 327(min 5.16 / max 12.87)

    Breakers SM3A with SMX2... contacts

    SM3A with SMX28 05 or SMX28 10 door coupling handle

    SMX28 05SMX28 10

    22.5

    (0.88

    )

    3.2 (0.12)

    min. 75(2.95)

    24.3

    (0.9

    6)

    16(0.63)

    70(2.75)

    165

    (6.5

    0)

    158 (6.22)

    5(1.97)

    33(1.30)

    17(0.67)

    25(0.98) 1...4 (0.04...0.16)

    min. 105 / max. 327(min 4.13 / max 12.87)

    Mounting on DIN rail.

    Mounting on DIN rail.

  • 1-15

    Motor protection circuit breakersDimensions [mm (in)]

    1

    LMH...

    30.8(1.21)

    9 (0.35)

    45(1

    .77

    )

    35(1

    .37

    )

    38(1.50)

    73.5(2.89)

    83(3.27)

    4(0.16)

    80(3

    .15

    )75

    (2.9

    5)

    Manual starters LMS25with side-mount LMH... contacts

    M25

    80(3.15)

    135

    (5.3

    1)

    39(1.53)

    18.5

    (0.7

    3)

    Enclosures LMZ111 - LMZ112with LMZ106 emergency stop button

    LMZ106

    95.5(3.76)

    55(2.16)

    M4

    M4

    M4

    105

    (4.1

    3)

    60(2.36)

    55(2.16)

    126

    (4.9

    6)

    69.5(2.74)

    85(3.35)

    129

    (5.0

    8)

    LMZ106

    80(3.15)

    12.5(0.49)

    55(2.16)

    105

    (4.1

    3)

    115

    (4.5

    3)

    70(2.75)

    LMZ113 - LMZ114with LMZ106 emergency stop button

    Drilling forsurface fixing

    Cutout

    SM1A. SM1B SM1C and SM2A SM3A and LMS25MOTOR PROTECTION CIRCUIT BREAKERS

    L1 L2

    T1 T2

    L3

    T3

    LINE

    LOAD

    Three-phase

    L1

    T1 T2

    L2LINE

    LOAD

    Singe phase or DC

    Wiring diagrams

    Connection busbars 45mm/1.77 spacing SMX90 32 - SMX90 33 - SMX90 34

    45 (1.77)

    Terminal block forbusbar supplySMX90 30

    1 L1 3 L2 5 L3

    Safety coverSMX90 31

    These elements mounted with LMS25... breakers with no auxiliary contacts

    SMX90 31

    SMX90 30

    SMX90 3...

    29 (1

    .14

    )

    13.5(0.53) 29

    (1.1

    4)

    13.5(0.53)

    These elements mounted with LMS25... breakers with LMH... auxiliary contacts

    SMX90 31

    SMX90 30

    SMX90 4...

    29 (1

    .14

    )

    13.5(0.53) 29

    (1.1

    4)

    13.5(0.53)

    Connection busbars 54mm/2.13 spacing SMX90 42 - SMX90 43 - SMX90 44

    54 (2.13)

    Terminal block forbusbar supplySMX90 30

    1 L1 3 L2 5 L3

    Safety coverSMX90 31

  • 1-16

    Motor protection circuit breakersWiring diagrams

    1

    Three-phase balanced operation Two-phase operation (phase failure/single phasing)THERMAL TRIP CHARACTERISTIC (AVERAGE TIME)

    1.5 2 3 4 5 6 7 8 910 20 30 40 50 6070 1001.2

    1.051

    1min

    2min

    5min

    10min

    30min

    1h

    2h

    0.001

    0.01

    0.1

    1

    10

    100

    1000

    10000

    x Ie[A]

    COLD

    HOT

    Opening time [s]

    1.5 2 3 4 5 6 7 8 910 20 30 40 50 6070 1001.151

    1min

    2min

    5min

    10min

    30min

    1h

    2h

    0.001

    0.01

    0.1

    1

    10

    100

    1000

    10000

    x Ie[A]

    COLD

    HOT

    Opening time [s]

    Tripping times can have a 20% deviation with respect to the average tripping curve values above.

    ADD-ON BLOCKSFor SM1 typesFront mount auxiliary contacts

    For SM2A and SM3A typesFront mount auxiliary contacts Side mount auxiliary contacts Side mount undervoltage trip releases Side mount shunt trip release

    For LMS25 types

    The termination of the LMH...auxiliary contacts has more thanone numbering due to the fact thatthe block can assume variousmounting positions. The numbering in boldfaceindicates when it is mounted on theleft side of the breaker.

    Side mount auxiliary contacts

    Side-mount auxiliary contacts

    Side mount undervoltage trip releases

    Inside-fitted undervoltage trip and shunt trip releases

    Side mount shunt trip releaseSMX11 1113 21

    14 22

    SMX21 1113 21

    14 22

    SMX12 1133 41

    34 42

    SMX12 2033 43

    34 44

    SMX22 1133 41

    34 42

    SMX22 2033 43

    34 44

    LMH 11

    13 21

    3244

    14 22

    3143

    LMH 20

    13 23

    3444

    14 24

    3343

    LMH 01

    32

    31

    11

    12

    LMH 10

    34

    33

    13

    14

    SMX12 0231 41

    32 42

    SMX22 0231 41

    32 42

    SMX13 1157 65

    58 66

    SMX11 2013 23

    14 24

    SMX20 1112 14

    11

    SMX23 1157 65

    58

    66

    77 85

    78 86

    LMU...

    U 125A gL/gG F2 =125A gL/gGF1 125A gL/gG F2 = not required.

    SPD COORDINATIONIn order to obtain an effective protection against overvoltage, it is advisable to install several SPDs coordinated with one another in cascade connection. For instance, it is advisable to have a Type 1 SPD in the main distribution board,a Type 2 SPD in the sub-distribution board and a Type 3 SPD near the terminalequipment to be protected. In this way, the energy originating from an overvoltage gradually decreases as itreaches the equipment to protect.

    DEFINITIONS AND RATINGSMaximum continuous voltage Uc: Maximum value of AC or DC voltage that the SPD is capable of permanentlywithstanding without activating or getting damaged; this is its rated voltage.

    Protection level voltage Up: Maximum value of the voltage between the terminals of the SPD in presence ofan impulsive overvoltage. It is a fundamental parameter to correctly choose theSPD; it must be taken into account with regards to the impulse voltage of theequipment to protect.

    Impulse current Imp:Crest value of the current that circulates in the SPD with a 10/350s waveform(activation must be guaranteed for 20 times without damage). It is used to classifySPDs in test class I.

    Rated discharge current In:Crest value of the current that circulates in the SPD with an (/20s waveform(activation must be guaranteed for 20 times without damage). It is used to classifySPDs in test class II.

    Open circuit discharge voltage Uoc:Crest value of the no-load discharge