EXISTING TENANT
EXISTING EQUIPMENT
REINSTALL EXISTING FIRE EXTINGUISHER
EXISTING SERVICE AREA
EXISTING TENANT
SEE 5/A301 SEE 1/A302FOOD COURT
REINSTALL EXISTING FIRE EXTINGUISHER
EXISTING BAG-N-BOX SYSTEM
□□00□0
□0
O0
o o
o0
o0
o o
-0 \ N EXISTING EQUIPMENT
SEE 2/A302
SEE 2/A302-
SEE 1/A301
SEE 2/A302
FRESHENSSEE 1/A301
SEE 2/A302
EQUIPMENT FLOOR PLANSCALE: 3/8" = 1-0
FRESHENS GENERAL NOTES:
1. IT IS THE LICENSED OPERATOR'S RESPONSIBILITY TO PROVIDE ALL CONSTRUCTION DOCUMENTS AS MAY BE REQUIRED BY LOCAL PERMITTING AUTHORITIES, OFTEN REQUIRING THE SERVICES OF A REGISTERED ARCHITECT AND/OR ENGINEER.
2. FRESHENS WILL WORK WITH THE OPERATOR'S ARCHITECT ON A CONSULTING BASIS ONLY. FRESHENS CANNOT PROVIDE SIGNED/SEALED CONSTRUCTION DOCUMENTS.
3. IT IS THE LICENSED OPERATOR'S RESPONSIBILITY TO VERIFY COMPLIANCE WITH ALL LOCAL CODES AND ORDINANCES. ANY DISCREPANCIES MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF FRESHENS.
4. THE LICENSED OPERATOR MUST PROVIDE QUALIFIED CONSTRUCTION TRADES (GC) TO PREPARE THE SPACE TO FRESHENS REQUIREMENTS INCLUDING (WHERE APPLICABLE), BUT NOT LIMITED TO; DEMOLITION, NEW PARTITIONS, FINISH MATERIALS, HARDWARE, PLUMBING AND ELECTRICAL ROUGH-INS AND FINAL CONNECTIONS.
5. THE GC SHALL VISIT THE JOB SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS, INCLUDING VERIFYING ALL DIMENSIONS AND LOCATIONS OF ALL EXISTING UTILITIES. ANY DISCREPANCIES OR OMISSIONS MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF FRESHENS.
6. A PRE-CONSTRUCTION MEETING (OR CONFERENCE CALL) WILL BE SCHEDULED A MINIMUM OF 6 WEEKS PRIOR TO OPENING.
7. A FOLLOW UP MEETING WILL BE SCHEDULED A MINIMUM OF 4 WEEKS PRIOR TO OPENING TO VERIFY THAT THE SITE IS READY TO RECEIVE MILLWORK AND EQUIPMENT AND IS ON SCHEDULE FOR OPENING.
8. IT IS THE INTENT THAT THE WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE PROVIDED.
9. THE GC WILL BE RESPONSIBLE FOR OFFLOADING ALL EQUIPMENT. IF A LOADING DOCK IS NOT AVAILABLE, UPON REQUEST, A TRUCK WITH LIFT GATE CAN BE PROVIDED. A PALLET JACK WILL BE REQUIRED TO ASSIST IN OFF-LOADING.
10. UPON RECEIPT, THE EQUIPMENT SHALL BE IMMEDIATELY INSPECTED FOR DAMAGE. ANY CLAIMS MUST BE FILED WITH SUPPORTING DOCUMENTATION AND IN ACCORDANCE WITH THE TERMS OF THE CARRIER RESPONSIBLE FOR YOUR DELIVERY. FAILURE TO DO SO MAY RESULT IN THE CARRIER REFUSING TO HONOR THE CLAIM.
11. UNLESS NOTED OTHERWISE, THE GC IS RESPONSIBLE FOR INSTALLING ALL EQUIPMENT AND MAKING ALL FINAL PLUMBING AND ELECTRICAL CONNECTIONS.
12. SOME EQUIPMENT MAY ARRIVE IN KNOCK-DOWN CONDITION AND WILL REQUIRE ASSEMBLY BY THE GC.
EQUIPMENT SCHEDULEMARK QTY DESCRIPTION MANUF/MODEL FURNISHED INSTALLED
FRESHENS FRESH FOOD STUDIO EQUIPMENT11 1 FOOD GUARD WITH LIGHTING 16" TALL ENGLISH MFG M112A - 150.5" CC MATTINGLY GC
12 1 HOT FOOD TABLE - PLATE SHELF-CUTTING BOARD EMI - TAMPA 48 X 38 X 36H MATTINGLY GC
13 1 DROP IN HOT FOOD WARMER APWWYOTT HFWAT-3D MATTINGLY GC
14 1 72" MAGATOP REFRIGERATOR DELFIELD 4472N-30M MATTINGLY GC
15 1 STAINLESS TABLE WITH PLATE SHELF, CUTTING BOARD EMI-TAMPA 22 X 38 X 36H MATTINGLY GC
16 1 STAINLESS TABLE 42 X 36 X 36, OPEN BASE, CASTERS EMI-TAMPA MATTINGLY GC
17 1 VENTLESS OVEN TURBO CHEF 2020T MATTINGLY GC
18 HOT HOLDING CABINET CAMBRO UPCH400 MATTINGLY GC
19 1 72" MAGATOP REFRIGERATOR DELFIELD 4472N-30M MATTINGLY GC
20 STAINLESS WALL SHELF, 15X48 ADVNACE TABCO WS-15-48 MATTINGLY GC
21 1 STAINLESS WARMER TABLE, 16 X 48 X 36 EMI - TAMPA MATTINGLY GC
22 1 STAINLESS CREPE IRON TABLE, 22 X 48 X 29.5 EMI - TAMPA MATTINGLY GC
23 1 DROP IN 4 /3 WARMER APWWYOTT HFW-43 MATTINGLY GC
24 1 MICROWAVE PANASONIC NE-1054 MATTINGLY GC
25 CREPE IRON KRAMPOUZ CEBIF4 MATTINGLY GC
26 1 CONVECTION STEAMER, STAND MARKET FORGE ALTAIR II-6 MATTINGLY GC
27 1 STEAM CONDENSER HOOD MARKET FORGE VEGA HOOD MATTINGLY GC
28 1 BLAST CHILLER DELFIELD CONVOCHILL T5 MATTINGLY GC
29 1 BLENDER HAMILTON BEACH HBF600 MATTINGLY GC
30 1 STAINLESS SHELF ADVANCE TABCO MS-18-24 MATTINGLY GC
31 1 SALAD CART EMI - TAMPA MATTINGLY GC
32 1 HAND SINK ADVANCE TABCO 7-PS-80 MATTINGLY GC
33 1 POS SYSTEM EXISTING OR BY OTHERS OWNER/OPERATOR OWNER/OPERATOR
SMOOTHIE EQUIPMENT42 1 LONG REFRIGERATED COLD PAN ATLAS WCMDCL-3 MATTINGLY GC
43 1 ICE CADDIE CAMBRO MATTINGLY GC
44 BLENDERS HAMILTON BEACH HBF650-FR MATTINGLY GC
45 1 RINSE SINK ADVANCE TABCO DI-1-10 MATTINGLY GC
46 1 BLENDER RINSER HAMILTON BEACH BCR-100 MATTINGLY GC
47 1 DIPPERWELL NEMCO SPADEWELL MATTINGLY GC
SIGN - MENU - GRAPHICS61 4 46-INCH DIGITAL MENU SYSTEM ALLURE GLOBAL MATTINGLY ALLURE GLOBAL
62 1 NUTRITIONAL TOUCH SCREEN ALLURE GLOBAL MATTINGLY ALLURE GLOBAL
63 2 DIGITAL MEDIA PLAYERS ALLURE GLOBAL MATTINGLY ALLURE GLOBAL
64 200 SF WALL GRAPHICS SOUTHEASTERN MATTINGLY SOUTHEASTERN
65 3 PREFINISHED WOOD COUNTER PANELS SOUTHEASTERN MATTINGLY SOUTHEASTERN
66 1 ILLUMINATED STOREFRONT SIGN, WALL MOUNTED SOUTHEASTERN MATTINGLY SOUTHEASTERN
OTHER EQUIPMENT
67 1 3 COMPARTMENT SCULLERY SINK AND FAUCETADVANCE TABCO 93-3-54-18L OWNER/OPERATOR GC
B-0231-BB-CR OWNER/OPERATOR GC
68 1 GARBAGE DISPOSAL (WITH SUPPORT LEG) SALVAJOR 200-SA-MRSS-LD OWNER/OPERATOR GC
SCOPE OF WORKSCOPE RESPONSIBILITY COMMENTS
ARCHITECTURAL AND ENGINEERING OWNERS ARCHITECT/ENGINEER
PERMITTING GENERAL CONTRACTOR
FLOORING AND BASE GENERAL CONTRACTOR PATCH AND REPAIR TO MATCH EXISTING
WALL FINISHES GENERAL CONTRACTOR PAINT AND FRP WHERE NOTED
CEILING FINISHES GENERAL CONTRACTOR PAINT AND FRP WHERE NOTED
MILLWORK GENERAL CONTRACTOR
MILLWORK SHOP DRAWINGS GENERAL CONTRACTOR
MILLWORK SHOP DRAWING APPROVAL FRESHENS / ARCHITECT
MILLWORK FABRICATION GENERAL CONTRACTOR UPON SHOP DRAWING APPROVAL
MILLWORK INSTALLATION GENERAL CONTRACTOR
EQUIPMENT INSTALLATION GENERAL CONTRACTOR
PLUMBING ROUGH IN GENERAL CONTRACTOR
FINAL PLUMBING CONNECTIONS GENERAL CONTRACTOR
ELECTRICAL ROUGH IN GENERAL CONTRACTOR
FINAL ELECTRICAL CONNECTIONS GENERAL CONTRACTOR
HVAC GENERAL CONTRACTOR
LIFE SAFTEY AND FIRE PROTECTION GENERAL CONTRACTOR MAINTAIN EXISTING SYSTEM DURING CONSTR.
VINYL GRAPHICS FRESHENS GRAPHICS COMPANY COORDINATED BY FRESHENS
L -
o
CD
o
£
u— I— I
CL
z>OCLoz :
U1
CCD
oEo
_CD
1_Q ‘ m
to D UCD O £
" D <u ON "
L - 15 I—
o OE
l o
N "
CDo OOoCN
LOc CD+-< CN* ‘d
• (/)"O
CD D CDL - 2 U
— "o>U
1cCD
LO
CD CD LO+ - *
D£ LO• — O "T_c U N"u O OO
IV i—O LO
o CN CN
U 1
l u < <o '
l a< LU 00 ZlN I I I Lü CÛN LU H U mk o y * *00 > O o
tz c - i 5< o Ô m §
Si £ 21 I 8 <
rEXCHANGEARMY a AIR FORCE EXCHANGE SERVICE
PROJECT NO: 1611010126
REVISIONS:
0 9 . 16.16ISSUE DATE:
'John a. M c A rth u r, nr #6431
NO IED
THIS DRAWING REPRESENTS DESIGNS PREPARED BY WATERMARK
DESIGN GROUP LLC FOR SPECIFIC USE ON THIS PROJECT AND IS NOT TO BE COPIED, REPRODUCED, OR ALTERED WITHOUT THE EXPRESS
WRITTEN CONSENT OF THE WATERMARK DESIGN GROUP
REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE.
UNAUTHORIZED USE IS SUBJECT TO LEGAL ACTION UNDER STATE AND
FEDERAL LAW.
SHEET TITLE:
EQUIPMENT PLAN
SHEET NUMBER:
A101