0-1%, - sdc securitya b 0v a b 0v 0v +12v mains present b/gl tamp 2-16 doors 17-32 default dhcp off...
TRANSCRIPT
(800) 413-8783 ■ www.SDCsecurity.com
IP Pro™ Access Control SolutionSingle Door Electric Latch Retraction Application
SYSTEM OPERATION
Door is normally closed and secured by an exit panic device.
Authorized Access: Presenting a valid card/fob or entering a valid user code on the keypad will momentarily retract the latch on the exit device, permitting access. The unlock time will be configured by the access control programming. The door may also be programmed for maintained access (dogging).
Manual Override: Key override is available from the unsecure side via optional active trim.
Authorized Egress: Free egress is available at all times by pressing the exit device pushpad, retracting the latch, and opening the door.
Low Voltage: System is powered by a regulated & filtered power supply with 12VDC output for access control equipment and 24VDC output for locking hardware to maximize efficiency.
IP-based Access Control: User-friendly programming interface via a built-in web server, accessible from any networked PC.
1 Access ControlIP Controller
Wiegand Reader Options (Choose one):3
5
4
IP Network AC Mains
S6100E LR100 Kit
IPRW
IPDCE
920PW 923PW
OPTIONAL CREDENTIALSFobs - HID1346-10Cards - HID1326-25
OPTIONAL:Latch & REXMonitoring
OPTIONAL BATTERY BACKUPRB12V4-2
3
5
21
Power Supply12 and 24VDC Output
Prox Reader or Keypad-Prox Combo
2
602RFX12VR
PTH-4Q* PT-3V PT-5*
Exit Device Electric Latch Retraction(Choose one):
Available formany brands
Complete Device or Field Retrofit Kit
(Choose one):*Power Transfer DeviceWire Transfer Hinge or Loops
4
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
IP Pro Single Door Applications
--
IP Pro™ 1-Door System with Electric Latch Retraction
- [email protected] IPPRO Apps-07/2015 Page 9 of 9
-
© 2015 Security Door Controls Printed in U.S.A
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
22/6C
(2) 18/2C
ACMains
(3) COND
602RFPowerSupplyx 12VR
Ethernet
NOCNC NOCNC
MAIN RELAYAUX RELAY
OP3
OP2 0V
AUX
1D
C PB
SENSECLOCK/D1DATA/D0+12V0VREDGREEN
A B 0V A B 0V 0V+1
2VM
AINS
PRES
ENT
B/G
LTA
MP
2-16 DOORS 17-32
DEFAULT
DHCP
OFF 1
2IP Pro™ Door Controller
(Door #1)
SDC P/N: IPDCE
24VDC
12VD
C
RJ-45
To PC or Local Network
Cat5 (or better)
FACTORY INSTALLED JUMPER(REMOVE ONLY IF FIRE ALARM INTERFACE IS CONNECTED)
VOLTAGE SELECTIONSWITCHES(SET FOR 24VDC)
TO 120VAC PRIMARYVOLTAGE CONNECTION
Battery InputTerminals
DC Voltage Output
Terminals
24 12
+ - + - C
602RF
+- +-
12VR
System Components:(1) 602RFX12VR – 1 Amp Regulated Power Supply w/ Fire Alarm Interface & 12VDC Output Module.(1) IPDCE – IP Pro™ Single Door ControllerChoose (1) Card Reader:
IPRW – Indoor/Outdoor Proximity Card Reader920PW – Single Gang Indoor/Outdoor Proximity Card Reader w/ Integral Keypad923PW – Frame mount Indoor/Outdoor Proximity Card Reader w/ integral Keypad
Choose (1) Electric Latch Retraction (ELR) Hardware Option:S6100E – Complete Rim Panic Device with ELRLR100 Kit – Field or Factory installed ELR Kit. Refer to the SDC website for available brands & models.
Choose (1) Power Transfer Device:PTH-4Q – 4-wire Power Transfer HingePT-3V – Armored Door Cord with Termination BoxPT-5 – Heavy Duty Power Transfer Device, Concealed Mortise Mount
(1) RB12V4-2 – Two 5Ah 12VDC Backup Batteries (Optional)(1) HID1346-10 – Ten Proximity Key Fobs (Optional)
+ -RB12V4
5 AMP HOUR BATTERY
+ -RB12V4
5 AMP HOUR BATTERY
SDC P/N: 602RFX12VR
EntryCard
Reader
SDC P/N: RB12V4-2
IP Network
18/4C
IP ProDoor
Controller
SDC P/N: IPRW
SDC P/N: 920PW
SDC P/N: 923PW
PowerTransfer
Hinge
RedBlk
WhtGrn
RedBlk
Spare
Spare
SDC P/N: PTH-4Q
To 2nd Door Controller
SDC P/N: IPDSEPTH-4QPower
TransferHinge
S6000EOR
LR100 SeriesLatch Retraction Kit
(Installed in Panic Device)
{To Optional
Latch or REX Monitoring
LR100 SeriesLatch
RetractionKit
Red (+)
Blk (-)
LR100 Series Latch Retraction/Dogging Kitavailable for these brands:
• Von Duprin• Yale• Corbin Russwin• Dor-O-Matic• Hager• Adams Rite• Dorma• Stanley K2• IDC• TownSteel
• Arrow• PHI• Falcon•Detex• Cal-Royal • PDQ• Falcon IR•Marshall Best• Sargent• SDC•Tell
Red (+)
Blk (-)
SDC S6000 Series Exit Device with factory installed Electric Latch Retraction Option
Complete Device for Rim, Mortise, or Surface Vertical Rod
UL Listed:ANSI/BHMA Grade1 Panic Exit Hardware, 3-Hr Fire Exit Hardware.