www ...wxdxh (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x...

47
www.rectifier.co.za / www.solar-solutions.co.za / www.batterysolutions.co.za / www.power-solutions.co.za

Upload: others

Post on 25-Mar-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 2: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

01 03 05

02 04 06

Began operations in 1994

23 years

Support

73 employees country wide

Warehouses

multiple warehouses around the country to be able to service our clients with power product solutions

Branches

Located in Johannesburg, Durban, Bloemfontein &

Cape Town, Mbombela, Tshwane

Stock

more than USD2, 500,000 invested in stock country wide

Growth

The company is growing at 10~20% per year with a turnover

achievement of over 109 Million for 2014.

Page 3: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

4 Branches

2 Franchises

JohannesburgBloemfonteinCapetown DurbanMbombelaTshwane

Page 4: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

•Additional service available for

servicing your system and backup batteries

• Installing yourSolar System / backup system

•Project team create a

unique Power Solution System

• Analysing your Power usage to create a system to suit your daily energy needs

Analysing Solution

ServiceInstalling

Page 6: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Standard 19 inches rack / tower configuration (2U).

Wide input voltage range reduces battery discharge probability prolongs battery lifetime.

Battery independent function to fulfill backup time by customized battery source. Specially for long backup application.

High recharging capability: Inbuilt 4.5-5A and optional 8A for 1kVA & 5A for 2/3kVA with extra charger box.

SMART slot for mission critical applications.

RS232 connectivity with Vista compatible power management software.

Optional external battery pack.

R Series 1-3 kVA

Applications

– Server Rack

– ATM

– Security

– Long Backup Time

Page 7: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Model R-1K R-2K R-3K

Power Rating 1kVA/700W 2kVA/1400W 3kVA/2100W

Voltage 220/230/240 Vac , single phase

Input Voltage Range 80 ~ 280 Vac. Lower range 80 ~ 175 Vac is acceptable under 50 ~ 100% loading condition.

Input Connection Power cord

Output Receptacle IEC320 C13 x 4 IEC320 C13 x 8 ; IEC320 C19 x 1

Battery Source Rating 36 Vdc 72 Vdc

Battery Charging Max. 5A Max. 4.5A

Optional Charger Board* Max. 8A Max. 5A

Internal Battery None! Customer can connect to their own battery source based on correct rating.

Interface RS232 x 1, SMART slot x 1

Tower Stand Kit Optional

Rack Rail Kit Included

Data Line Surge Protector Optional

External Battery Pack Optional. Connection is by Delta standard battery cable.

WxDxH (mm) 440 x 455.4 x 88.5

Weight (kg) 6.7 9.2

R Series Specifications

Page 8: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Standard 19 inches rack / tower configuration (2U).

High input power factor (pf > 0.97) saves installation cost.

Wide input voltage range reduces battery discharge probability prolongs battery lifetime.

RS232 and USB connectivity with Vista compatible power management software.

Inbuilt data line surge protector for phone / fax / network.

Programmable output receptacles for efficient energy usage.

SMART slot for mission critical applications.

Optional external battery pack

GAIA Series 1-3 kVA

Applications

– Server Rack

– ATM

– Security

– Audio/Video

Page 9: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Gaia Series Specifications

Model GAIA-1K GAIA-2K GAIA-3K

Power Rating 1kVA/800W 2kVA/1600W 3kVA/2100W

Voltage 200/208/220/230/240Vac, single phase

Input Voltage Range 130~275 Vac (Lower range 130 ~ 160 Vac is acceptable under 70% ~ 100% loading condition)

Power factor > 0.97

Output Receptacle IEC320 C13 x 3 x2 IEC320 C13 x 3 x 2; IEC320 C19 x 1

Internal Battery 12V/8.5Ah x 2 12V/8.5Ah x 4 12V/8.5Ah x 6

Backup Time> 12 minutes (half load)> 4 minutes (full load)

> 13 minutes (half load)> 4 minutes (full load)

> 15 minutes (half load)> 5 minutes (full load)

EBC Rating 8.5Ah x 2 x 2 8.5Ah x 4 x 2 8.5Ah x 6 x 2

Interface RS232 x 1, USB x 1, SMART slot x 1

Data Line Surge Protector Built-in (RJ11/RJ45, phone and network)

Tower Stand Kit Included in package

Rack Rail Kit Optional

External Battery Pack Optional

WxDxH (mm)UPS

440 x 335 x 89 440 x 432 x 89 440 x 610 x 89Battery Pack

Weight (kg)UPS 13 21 31

Battery Pack 16 29 43

Page 10: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Standard 19 inches rack / tower configuration (5/6kVA:2U 10kVA:3U).

High output power factor 0.9

1+1 parallel redundancy to increase the reliability and flexibility.

High input power factor (pf > 0.99) and low input harmonic distortion (iTHD < 5%).

High recharging capability: Inbuilt 4A and optional 4A extra charger.

One SMART slot and MINI slot for mission critical applications.

Multi-language LCD display and status LED.

Optional maintenance bypass box

Optional external battery pack and charger box.

RT Series 5-10 kVA

Applications

– IT Room

–Security

–Banking

–Long Backup Time

Page 11: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

RT Series Specifications

Model RT-5K RT-6K RT-10K

Power Rating 5kVA/4.5kW 6kVA/5.4kW 10kVA/9kW

Voltage 200/208/220/230/240 Vac , single phase

Input Voltage Range 100 ~ 300 Vac

Input/Output Connection Hard wire (terminal block)

External Battery Pack Rating 12V/5Ah x 16 12V/9Ah or 12V/34W x 20

Battery Charging Max. 4A

Optional Charger Board** Max. 4A

Internal Battery No built-in battery. Customer can connect to their own battery source based on correct rating.

Interface RS232 x 1, SMART slot x 1, MINI slot x 1, Parallel port x 1

Rack Rail Kit Optional (tower stand kit is included)

Parallel Redundancy 1+1

Maintenance Bypass Box Optional

WxDxH (mm)UPS 440 x 671 x 89 440 x 671 x 89 440 x 623 x 131

Battery Pack 440 x 638 x 89 440 x 638 x 89 440 x 595 x 131

Weight (kg)UPS 15 15.5 21.3

Battery pack 36 36 66

Page 12: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

EH Series 10 -20 kVA

HPH Series 20 - 40 kVA

NT Series 20 - 500 kVA

DPS Series 60 - 400 kVA

Delta UPS – Ultron Family

Three Phase Online UPS

Up to 4000 kVA

Page 13: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

A true online double-conversion 3phase-1phase UPS

Advanced DSP controller for fast computation capability and a simplified control circuit for enhanced stability

Dual input design to allow different power supply sources for enhanced availability

Built-in manual bypass to ensure continuous power to the load even if the UPS is under maintenance

A wide input voltage range to reduce battery discharge probability and prolong battery life

ECO mode efficiency up to 96% to reduce operating costs

Parallel expansion and N+X redundancy up to 4 units without requiring additional cards or equipment

Small footprint to save space

EH Series 10-20 kVA

Applications

–Networking

–Data centers

–Telecommunications

–Medical

–Banking

–Retail

–Industrial

Page 14: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

EH Series 10-20 kVA

Model EH-10K EH-15K EH-20K

Power Rating 10kVA /8kW 15kVA /12kW 20 kVA/16kW

Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac

Input Voltage Range 208~304 Vac ( 50%~100% load) / 305~477 Vac (100% load)

Output Voltage 220/230/240 Vac

Overload Capability≤105 %: continuous; 106%~110%: 10 minutes;

111%~125%: 1 minute; 126%~150%: 30 seconds

EfficiencyOnline Mode: up to 91%

ECO Mode: up to 96%

Charge CurrentBuilt-in: 4A

Additional charger board (optional): 4A

Charge VoltageFloat charge 272 +/- 2 Vdc

Boost charge 280 Vdc

InterfaceSMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1,

REPO Port x 1, Charger Detection Port x 1

Maintenance Bypass Switch Built-in

WxDxH (mm) 200 x 490 x 490 mm 250 x 610 x 650 mm

Weight UPS 26 Kg 45Kg

Page 15: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

HPH Series 20-40kW

Applications

–Data centers

–Telecom

–Network

–Banking

–Medical

–Metro

–Industrial

Fully rated power (kVA=kW) for maximum available power

Leading AC-AC efficiency up to 96% saves energy costs

Low harmonic pollution (iTHD<3%) & high input power factor (>0.99) reduce upstream investment costs

Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life

DSP based technology enables reduction in the number of electronic components to lower failure rate

N+X redundancy up to 4 units increases system availability

Built-in manual bypass ensures continuous power to the load even if the UPS is under maintenance

Flexible arrangement of battery quantity from 34 to 50 pcs optimizes battery investment

Page 16: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

HPH Series 20-40kW

ModelHPH-20K

HPH-20K-BN/BHPH-30K

HPH-30K-BN/BHPH-40K

HPH-40K-BN/B

Power Rating 20kVA /20kW 30kVA /30kW 40 kVA/40kW

Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac

Input Voltage Range - 40% ~ 20% (242 ~ 477/140 ~ 276 Vac) * *

Output Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac

Overload Capability≦105 %: continuous; 106%~≦125%: 10 minutes;

126%~≦150%: 1 minute; >150%: 1 second

Battery Charging (Standard model) 5A 9A

Battery Charging (HPH-BN/B*) 5A, 9A (option)

Charge VoltageFloat charge ±272 V ±2Vdc,Boost Charge ±280V ±2Vdc

Typical Backup Time (HPH-BN/B*)

(At 70% load with internal battery strings)15 min 10 min 9.5 min

EfficiencyOnline Mode: up to 96%

ECO Mode: up to 99%

InterfaceSMART Slot x 1,MINI Slot x 1, Parallel Port x 2, RS232 Port x 1,

REPO Port x 1, Charger Detection Port x 1, Input Dry Contact x 2,Output Dry Contact x 6

Maintenance Bypass Switch Built-in

*HPH-BN: UPS integrated battery model has no batteries inside

HPH-B: UPS integrated battery model has batteries inside

* *When input voltage is 242 ~ 324/140 ~ 187 Vac, the sustainable loading is

from 70% to 100% of the UPS capacity.

Page 17: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Applications

–Networking

–Data centers

–Telecommunications

–Medical

–Banking

–Industrial

N+X parallel reduncancy (up to 8 units) for reliability and flexibility, w/o extra hardware.

Economic mode for energy and operation cost savings.

Inbuilt automatic and manual bypass switch.

Inbuilt SRAM recording maximum 500 real-time event logs.

Compatible with generator installation.

6 configurable UPS status dry contact outputs.

Optional 12-pulse rectifier or filter for lower harmonic distortion.

Possibility for shared battery source enabling cost savings.

Custom order voltage rating.

Optional external battery cabinet.

NT Series 20-500 kVA

Page 18: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

NT Series Specifications

NT- 20 K 30 K 40 K 50 K 60K 80K 100K 120 K 160 K 200 K 260 K 320 K 400 K 500 K

WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 19501900 x 995 x 1950

Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

* The table above is based on 220/380 Vac rating.** 500kVA model is assembled by two cabinets: Inverter (width=11m, 1760kg) and rectifier (width=8m, 650kg). ***Dimension and weight are for the standard model with 6pulse rectifier.

NT-series generic specification

Voltage 120/208, 220/380, 230/400, 240/415, 277/480 Vac (Three phase, 4 wire plus ground)

Voltage Range ±20 %

Interface RS232 x 1, RS485 x 1, SNMP slot x 1, Dry contact output x 6

Parallel Redundancy Maximum 8 units

Input Harmonic Improvement Optional 12-pulse rectifier or filter

SRAM Event Log Maximum 500 records

Battery Start Yes

Page 19: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Applications

–Networking

–Data centers

–Telecommunications

–Medical

–Banking

–Industrial

IGBT-based UPS with AC-AC efficiency up to 96%

0.9 output power factor, and supporting leading power factor data center server, networking equipment

Able to parallel for N+X redundancy, hot stand-by and support 2(N+1) configuration to meet level tier 4 reliability

Wide input voltage range reduces battery discharging

Advanced battery management optimizes battery performance and lifetime

Field programmable sequential start-up 2 to 99 seconds

Hot swappable fan design

Optional Redundant fan design

Ultron DPS Series 60-400 kVA

Page 20: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

DPS Series Specifications

Model DPS 60 DPS 80 DPS 100 DPS 120 DPS 160 DPS 200 DPS 300 DPS 400

Power Rating60kVA /54kW

80kVA /72kW

100kVA /90kW

120kVA /108kW

160kVA /144kW

200kVA /180kW

300kVA /270kW

400kVA /360kW

Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground)

Input Voltage Range 208~477 Vac* 242~477 Vac*

Input Power Factor > 0.99

Current Harmonic Distortion

< 3% (full load)

Output Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground)

Output Voltage Regulation

± 1% (static)

Interface

RS232 x 1, Smart slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 2, Battery cabinet temperature sensor x 4, REPO x 1

RS232 x 1, Smart slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 2, Battery cabinet temperature sensor x 4, Battery status detection x 1, REPO x 1

Parallel Link Up to 4 units Up to 8 units

EfficiencyAC-AC: Up to 96%

ECO mode: Up to 99%

WxDxH (mm) 520 x 975 x 1695 850 x 865 x 1950 1600 x 865 x 1950

Weight (kg) 300 330 360 390 697 1335

* When input voltage is 208~300 / 242~324 Vac,

the sustainable loading is from 70% to 100% of

the UPS capacity.

Page 21: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Delta UPS – Modulon Family

Three Phase Modular Online UPS

- Up to 800 kW online UPS

NH Plus Series 20 - 120kVA

DPH Series 25 - 200 kW

Page 22: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Applications

–Networking

–Data centers

–Telecommunications

–Medical

–Banking

–Industrial

Hot-swappable function providing uninterruptible power during module replacement.

N+X parallel reduncancy(up to 4 units, max. 480kVA) for reliability and flexibility, w/o extra hardware.

High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 3%).

94% high efficiency saving operation cost.

Inbuilt automatic and manual bypass switch.

Inbuilt SRAM recording maximum 500 real-time event logs.

Multi-language LCD display and status LED indicators

Compatible with generator installation.

6 configurable UPS status dry contact outputs.

Optional kit for monitoring battery cabinet temperature.

NH Plus Series 20-120 kVA

Page 23: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

NH Plus Series 20-120 kVA

* Subject to reconfiguration of the UPS; Delta provides the

configuration service.

** When input voltage is 208~300/120~173 Vac, the sustainable

loading is from 70% to 100% of the UPS capacity.

Model NHP-20K NHP-40K NHP-60K NHP-80K NHP-100K NHP-120K

Power Rating* 20kVA /18kW 40kVA /36kW 60kVA /54kW 80kVA /72kW 100kVA/90kW 120kVA/108kW

Voltage 380/220, 400/230, 415/240 (3 phase, 4-wire plus ground)

Input Voltage Range

208 ~ 477 Vac (line-line) / 120 ~ 276 Vac (line-neutral)**

Input Power Factor > 0.99

Input Current Harmonic Distortion

< 3% (full load)

Output Voltage380/220, 400/230, 415/240 (3 phase, 4-wire plus ground)

Other rating is available in another cabinet (I/P and O/P transformer is included)

Connection Hard wire (terminal block)

InterfaceRS232 x 1, SNMP slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 1, Battery cabinet temperature sensor x 4, Battery cabinet status detection x 1, Remote emergency power off x 1

Parallel Link Up to 4 units. Maximum 480 kVA

External Battery Cabinet

Optional

WxDxH (mm) 520 x 910 x 1165 520 x 975 x 1695

Weight (kg) 112.5 128 230 260 350 380

Page 24: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Summary

Stored energyUninterruptible power supply

Applications

–Data centers

–Telecommunications

–Network

–Banking

–Industrial

Advanced fault tolerance design achieved by self redundancy to guarantee operation continuity

Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure

Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero

Vertical expansion from 25kW to 200kW supporting N+X redundancy in a single rack enclosure to save footprint

Full rated power (kVA=kW) to maximize power availability

High operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings

Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements

DPH Series 25-200kW

Page 25: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

DPH Series 25-200kW

Model 25 50 75 100 125 150 175 200

Power Rating* 25kVA/kW 50kVA/kW 75kVA/kW 100kVA/kW 125kVA/kW 150kVA/kW 175kVA/kW 200kVA/kW

Voltage 380/220, 400/230, 415/240 (3 phase, 4-wire plus ground)

Input Voltage Range

176~276 / 305~477 V

(When input voltage is 140/242~176/305 Vac, the sustainable loading is from 60% to 100% of the UPS capacity)

Input Power Factor

> 0.99

Input Current Harmonic Distortion

< 3% (when input harmonic distortion is less than 1%)

Output Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground)

InterfaceParallel port x 2, Smart slot x 2, Dry contact output x 6,

Dry contact input x 6, SNMP card x 2, Battery dry contact x 6

Parallel Link Up to 4 units. Maximum 800 kW

External Battery Cabinet

Optional

WxDxH (mm) 600 x 1090 x 2000

Weight (kg) 382 414 446 478 510 542 574 606

Page 26: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Delta Rectifiers

Summary

Stored energy Telecommunication

Page 27: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

DPR 850-48 DPR 2900-48 DPR 2900-48 DPR 3000-48 DPR 4000-48 DPR 6000-48

Power output 850 W 2900 W 2900 W 3000 W 4000 W 6000 W

Efficiency 95.2% 96.4% 97.2% 98,0% 95.2% 96.5%

Power density 30 W / in3 36.5 W / in3 36.5 W / in3 56,8 W / in3 27.3 W / in3 26.5 W / in3

Control and monitoring

ORION, ORION eco, ORION c

Hot-pluggable Yes Yes Yes Yes Yes Yes

Dimensions (W x H x D)51.8 x 40.0 x 247.2 mm

125.5 x 41.0 x 269.9 mm

125.5 x 41.0 x 269.9 mm

84,0 x 41.0 x 270.0 mm

82.0 x 86.9 x 377.9 mm

129.5 x 83.0 x 380.7 mm

Weight 0.6 kg 2.0 kg 2.0 kg 1,4 kg 3.5 kg 5.2 kg

Cooling Fan cooled with speed control

Safety EN / IEC 60950; UL 60950; CAN / CSA – C22.2

EMI (radiated) EN 55022 class B

Environment RoHS compliant

Rectifiers

Page 28: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Self Power - CellD

Summary

Stored energy Telecommunication

Page 29: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CellD Systems

CellD 20 CellD 40 CellD 100 CellD 125 (EVO)

DPS 850B-48-2 DPS 850B-48-3 DPS 850B-48-6 DPS 2900B-48-3 DPS 2900B-48-3

Rectifier moduleDPR 850B-48 (max. 2 pcs.)

DPR 850B-48 (max. 3 pcs.)

DPR 850B-48 (max. 6 pcs.)

DPR 2900B-48 (max. 3 pcs.)

DPR 2900B-48 (max. 3 pcs.)

Efficiency 95,2% 95.2% 95.2% 96.4% or 97,2% 96.4% or 97,2%

Install power (max. config.)

1,7 kW 2.55 kW 5.1 kW 8.7 kW 8.7 kW

Dimensions H x W x D43.6 (1U) x 484.3 (19’)

x 280 mm43.6 (1U) x 484.3 (19’)

x 280 mm86.8 (2U) x 484.3 (19’)

x 295 mm86.8 (2U) x 484.3 (19’)

x 323 mm133.5 (3U) x 481.5 (19’)

x 329 mm

Weight 4.0 kg 4.1 kg 7.0 kg 7.0 kg 15 kg

Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS

Max. output current / max. installed power

26 A / 1,7 kW 40 A / 2.55 kW 100 A / 5.1 kW 100 A / 8.7 kW 125 A / 8.7 kW

Controller ORION

Local interface Display, keypad, LEDs

Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

Page 30: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CellD Systems

CellD 300 (EVO2)

DPS 2900B-48-3 19IN-5U DPS 2900B-48-5 19IN-5U DPS 2900B-48-6 19IN-6U DPS 2900B-48-3 21IN-4U DPS 2900B-48-6 21IN-5U

Rectifier moduleDPR 2900B-48 (max. 3 pcs.)

DPR 2900B-48 (max. 5 pcs.)

DPR 2900B-48(max. 6 pcs.)

DPR 2900B-48 (max. 3 pcs.)

DPR 2900B-48 (max. 6 pcs.)

Efficiency 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2%

Install power (max. config.)

8.7 kW 14.5 kW 17.4 kW 8.7 kW 17.4 kW

Dimensions H x W x D222 (5U) x 479,7 (19’)

x 315 mm222 (5U) x 479,7 (19’)

x 315 mm266 (6U) x 479,7 (19’)

x 315 mm177 (4U) x 534 (21’)

x 315 mm222 (5U) x 534 (21’)

x 315 mm

Weight 13 kg 14 kg 14 kg 13 kg 14 kg

Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS

Max. output current / max. installed power

250 A / 8,7 kW 250 A / 14,5 kW 250 A / 17.4 kW 250 A / 8.7 kW 250 A / 17.4 kW

Controller ORION

Local interface Display, keypad, LEDs

Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

Page 31: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CellD Systems

CellD 600

DPS 2900B-48-12 19IN-9U DPS 4000B-48-5 19IN-7U

Rectifier module DPR 2900B-48 (max. 12 pcs.) DPR 4000B-48 (max. 5 pcs.)

Efficiency 96.4% or 97,2% 95.2%

Install power (max. config.) 34.8 kW 20 kW

Dimensions H x W x D 399 (9U) x 480 (19’) x 375 mm 311 (7U) x 480 (19’) x 465 mm

Weight 30 kg 25 kg

Input voltage range 80 - 300 VRMS 80 - 300 VRMS

Max. output current / max. installed power

600 A / 34.8 kW 600 A / 20 kW

Controller ORION

Local interface Display, keypad, LEDs

Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

Page 32: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CellD Additional ElementsSite Support cabinets

SC600 SC770 SC1300 SC1800 SC2000

Internal space 12 U 15 U 27 U 38 U 42 U

Height 620 mm 759 mm 1295 mm 1790 mm 1961 mm

Width 600 mm

Depth 450 or 600 mm

Wall BoxWB 5U WB 8U WB 12U

5 U / 19‘ 8 U / 19‘ 12 U / 19‘

253 mm 387 mm 564 mm

548 mm

475 mm

AC and/or DC Panel

DPD/APD/DAPD 19IN-3U DPD /APD/DAPD 21IN-3U

Operating voltage / Current (max.)AC: 230 / 400 V (1 or 3 ph) / Related to equipment

DC: 20-60 V / 300 A

Internal space 24 modules (18 mm) 27 modules (18 mm)

Dimensions H x W x D 133 (3U) x 480 (19’) x 190 mm 133 (3U) x 530 (21’) x 190 mm

Page 33: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Cabinet Power - CabD

Summary

Stored energy Telecommunication

Page 34: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CabD 600 CabD 1000 CabD 1500 CabD 2000

Standalone / Multicabinet Standalone Cabinet Multicabinet (Parallel option) Multicabinet (Parallel option) Multicabinet (Parallel option)

Rectifier moduleDPR 6000 (max. 8 pcs), DPR 4000 (max.12 pcs), DPR 2900 (max.12 pcs)

DPR 6000 (max. 12 pcs)DPR 4000 (max. 18 pcs), DPR 2900 (max. 24 pcs)

DPR 6000 (max. 16 pcs),DPR 4000 (max. 24 pcs),DPR 2900 (max. 28 pcs)

DPR 6000 ( max 20 pcs)DPR 4000 (max. 30 pcs),

Max. output current /max. installed power

600 A / 34.8 kW 1000 A / 72 Kw 1500 A / 96 kW 2000 A / 120 kW

Efficiency 95.2% ... 97,2% 95.2% ... 97,2% 95.2 % ... 96,5 % 95.2 % ... 96,5 %

AC configuration 3L+N+PE or 3L+PE

Load and battery connection

Configurable – modular design

Controlling and monitoring

ORION

Operating temperature -5 - +45 °C

CabD Systems

Page 35: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CabD Systems

CabD 3000 CabD 3000+

Standalone / Multicabinet Multicabinet (Parallel option) Multicabinet (Parallel option)

Rectifier moduleDPR 6000 (max. 24 pcs), DPR 4000 (max.36 pcs)

DPR 6000 (max. 24 pcs),DPR 4000 (max. 36 pcs)

Max. output current /max. installed power

3000 A / 144 Kw 3000 A / 144 kW (scaled up horizontal DC bus bars)

Efficiency 95.2% ... 96,5 % 95.2 % ... 96,5 %

AC configuration 3L+N+PE or 3L+PE

Load and battery connection

Configurable – modular design

Controlling and monitoring

ORION

Operating temperature -5 - +45 °C

Page 36: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

CabD Systems - options

Controller Battery connection Battery connection Battery connection

Controller shelf 1UBattery fuse TPS2up to 4x 1600 A

Battery fuse EFEN NH3 up to 4x 630 A

Battery fuse EFEN NH2up to 4x 400 A

Load connection Load connection Load connection Load connection

DPD 8x EFEN NH002..160 A

DPD 7x NH02100..400 A

DPD 30x MCB2..63 A

DPD 13x 22x582..100 A

Page 37: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Inverter Systems

Summary

Stored energy Telecommunication

Page 38: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

APS 750B-230-8 19IN APS 1500B-230-8 19IN APS 2500B-230-8 19IN APS 2500B-230-24 CabD

Inverter modules(Max. configuration)

8x TSI NOVA - 230Vac 8x TSI MEDIA - 230Vac 8x TSI BRAVO - 230Vac 24x TSI BRAVO - 230Vac

Max. installed power 6 kVA / 4,2 kW 12 kVA / 9,6 kW 20 kVA / 16 kW 60 kVA / 48 kW

Efficiency (EPC mode) 93 % 94 % 96 % 96 %

AC configurationInput / Output

One phase / One phase One phase / One phase or

Three phases / three phases

Output loadsAC distribution

Configurable (MCBs, RCDs, bulk type) - modular design

Controlling and monitoring

T2S - ORION

Manual Bypass optional

Inverter System

Page 39: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Outdoor Systems - OutD

Summary

Stored energy Telecommunication

Page 40: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

OutD: V series

OutD V Series

Key advantages

• Single or Multilayer wall design

• -7dB(A) (lower than standard cabinets with the same cooling capacity)

• Steel or aluminium outside walls

• Flexible configuration - 19’ or 21’ racks, battery shelves, multiple PSU options (power supply systems), multiple cable management options

• Multiple cooling options (AV, AC, Hybrid AC+AC)

• Battery cooler (Separated battery compartment with advanced thermal insulation 40mm EPS and active cooling (TEC or AC)

Dimensions

OutD 0.7V H701 x W605 x D530mm - 12HU (plinth H100mm excl.)OutD 1.2V H1257 x W708 x D752mm - 21HUOutD 1.8V H1860 x W708 x D752mm - 35HUOutD 2.0V H2047 x W808 x D852mm - 39HUOutD 2.2V H2247 x W808 x D852mm - 44HU

Material Steel or Aluminium, Single or multilayer with optional thermal insulation

Lifetime Steel : up to 15 year, Aluminium: up to 20 years

Cooling options

AV (Air Ventilation), HEX (Heat Exchanger,) AC (Air con), Hybrid AV+AC (Hybrid cooling Air Ventilation + Air con)

Page 41: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

OutD: M series

OutD M Series

Key advantages

• Single or Multilayer wall design

• -7dB(A) (lower than standard cabinets with the same cooling capacity)

• Flexible configuration - 19’ or 21’ racks, battery shelves, multiple PSU options (power supply systems), multiple cable management options

• Battery box extension (battery cooler)

• IP20 equipment extension

• Side by side connection available

DimensionsOutD 1.5M H1500 x W770 x D852mm - 28HUOutD 1.8M H1829 x W770 x D852mm - 35HUOutD 2.0M H2052 x W870 x D952mm - 40HU

Material Steel or Aluminium, Single or multilayer with optional thermal insulation

Lifetime Steel : up to 15 year, Aluminium: up to 20 years

Cooling Options

AV (Air Ventilation), HEX (Heat Exchanger,) AC (Air con), Hybrid AV+AC (Hybrid cooling + Air Ventilation + Air con)

Page 42: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Small Cell Power

Summary

Stored energy Telecommunication

Page 43: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Small Cell Power – DPR 1000B-45

Small Cell – Outdoor Rectifier

Dimensions H360 x W209,8 x D88,8mm

EN 60529 class IP65

Material Aluminium

Weight 6,4kg

User Interface Status Indication

Mounting Lamppost, pole or wall mountable

Cooling options Natural Cooling

PSU Power 1000W / 42 - 58Vdc

EMC EN55022, CISPR22, FCC 15 class B

Operating temperature-40°C to +60 °C (linear power de-rating to 50% load from 46°C to 60°C)

Humidity (relative) 95%, non-condensing (Max.)

ConnectorsAC input: Amphenol PWC-03RMMS-LC7002 x 1 Dc output: Amphenol PWC-03RMFS-LC7002 x 2 Alarms: Amphenol CD-09RMFS-LC7001 x 1

Options Service LED light, Alarm terminals

Page 44: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Small Cell Design - BoxD

Small Cell - BoxD

Dimensions H684 x W489 x D312mm

EN 60529 class up to IP55

MaterialEnclosure: AluminiumInternal Parts: Galvanized steel

Wall structure Single layer with sun radiation screen

Lifetime Steel: 10+ years

Mounting Wall / Pole

Cooling optionsHEX (Heat Exchanger) 15W/KAV (Air Ventilation)*TEC (Peltier Module)*

PSU Power 2x850W / 48Vdc

Battery supervisionNoneLVD onlyORION + Shunt/LVD

Battery backup19” space

- 14Ah 24Ah2.5U 1U -

Cable glands 4xPG16 4xPG13.5 2xPG11

Options Service LED light, Alarm terminals

Page 45: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Controller and network monitoring

Summary

Stored energy Telecommunication

Page 46: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

Battery management, supervision

and control (Pb/LI) incl. Battery

profile management

Remote communication via LAN,

SNMP, Modbus and I-Phone App

incl. enhanced security by SNMP

V3 and IP filtering

Power System and rectifier

management and control incl.

efficiency mode, alarming and

parameter setting

Easy configuration management

including inventory reporting,

language support and configurable

data logging features

Full site control and management of:

• Gensets

• Batteries

• Cooling devices (Aircon, HEX, fans)

• Hybrid mix

• Site access

• Site inventory

• IP camera

Smart metering and alarming of:

• Site energy consumption

• Temperature & Humidity

• Smoke detector

• Flood detector

• Intrusion detector

• Any kind of other external devices

Easy integration of hybrid energy

sources

• Solar

• Wind

• Genset

2017 update:

• Upgraded with touch panel • 1GB Lan connection -> IT network integration• New µC and more memory • 25% less power consumption• Micro SD slot -> simplified field service

1

2

3

4

5

6

7

ORION Controller

Page 47: www ...WxDxH (mm) 600 x 800 x 1400 800 x 830 x 1700 1200 x 830 x 1700 1600 x 995 x 1950 1900 x 995 x 1950 Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2410

ORION Controller

ORION c

• Orion ID E1 - TPS1020028A • Full functionality, all features

• Orion ID C1 - TPS1020029A• Full functionality, all features• Used for upgrading systems originally

installed with PSC3 controller

• Orion ID G1 - TPS1020030A• Limited functionality for low cost

applications

ORION eco

ORION Controller