SR.NOPRODUCT NAME MODEL NAME PAGE NO

1 AUTOMATIC MAIN FAILUER-3PHASE AMF-65E 12 AUTOMATIC MAIN FAILUER-SINGLE PHASE AMF-9 23 MULTIFUNCTION METER MFM-4L 3

4 DUAL SOURCE METER DSL-4 45 KWH METER KWK-1L 56 ENGINE CONTROL SYSTEM- ECS-65 67 GENRATOR SAFTY UNIT GSU-65 78 VAF-HOUR METER VAF-H 89 AUTO TRANSFER SYSTEM –DIGITAL ATS-D 9

10 LINE PROTECTOR UNIT LPU 1011 LINE VOLTAGE MONITOR LVM-PM 1112 DESEL ENGINE SAFTY-DIGITAL DES-D1 1213 DESEL ENGINE SAFTY-DIGITAL DES-D 1314 WATER LEVEL MONITORING WITH GSM WLM-GSM 1415 GENERATOR SAFTY UNIT GSU 1516 ESU-01 SU-01 1617 ENGINE CONTROLL PANEL ECP 1718 AUTO TRANSFER SYSTEM ATS 1819 LINE VOLTAGE MONITORING-DIGITAL LVMD 1920 OVER LOAD RELAY ORT 2021 AUTO CHANGOVER CUM LIMITTER-PTC ACCL-PTC 2122 AUTO TRANSFER SYSTEM-PTC ATS-PTC 2223 AUTO CHANGOVER CUM LIMITTER-DIN ACCL-DIN 2324 AUTO TRANSFER SYSTEM-PTC ATSC-PTC 2425 AUTO CHANGOVER CUM LIMITTER-3PHASE) ACCL-3 2526 WATER LEVEL CONTROLLER-1 WLC-1 2627 SINGLE PHASE PRIVENTOR SPP 2728 OTHER PRODUCTS 28

Page 3: Web viewproduct brocher . product brocher . table of contained. sr.no

1

AUTOMATIC MAINS FAILURE CONTROLLER 3-Phase (MODEL: AMF65E)

SALIENT FEATURES:

1. AMF Works in 3 modes AUTO, MANUAL and BY PASS.2. 3-Phase mains input for Line voltage monitor (LVM).3. 3-Phase DG input.4. 16 X 2 LCD & LED for Display and status indication.5. Nine inputs for Engine status monitoring (inputs are +ve or –ve active).6. Out of nine three inputs are Analog i.e. Fuel, Temp. And Pressure Gauges.7. Five out puts for control.8. Out of five, three out puts are Digital i.e. +ve drives for START, STOP and Hooter.9. Two potential free relays contacts for switching Load on Mains or Load on DG.10. Unit Inputs are optically isolated for signals.11. AMF Working on auxiliary power 9vdc to 36vdc.12. Provision of functional keys namely Start, Stop, Set, Up, Down, Acknowledge and Reset, for

Calibration and parameter setting purpose. 13. Display DG’s frequency, RPM, Run, Voltage, Current , KW, KVA, KWH, KVAH14. RS 232 port for remote communication. 15. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM:

1 2 3 4 5 6 7 8 9 10 11 12 13FG TG P G TE TP LP ES BP IND NR Y B

M A INS

14 15 16 17 18 19 20 21 22 23 24 25 26-B + B ST SP HT NO PL NO PL NR Y B

DG

2829

3031

32s1

s2s1

s2s1

s2CT

_YCT

_BCT

_R27

RS 2

32

1. FG - Fua l G a uge2.TG - Tem p. Gauge3.PG - P re ss. Ga uge4.TE - Ta nk Em pty5.TP - High Te m p.6.LP - Low oil P re ss.7.ES - Em e rge ncy stop8.BP - Bypa ss 9.IND - Cha rge r

13.N - Ne utra l

10.R - R P ha se11.Y - Y P ha se12.B - B P ha se14.-B - BAT -ve15.+ B - BAT + ve16.S T - S TART17.S P - S TOP18.HT - Hoote r19.NO - NO M a ins20.P L - P ole M a ins

21. NO - NO DG22.PL - P ole DG

26.N - Ne utra l

23.R - R P ha se24.Y - Y P ha se25.B - B P ha se

27.s1 - R P ha se CT28.s2 - R P ha se CT29.s1 - Y P ha se CT30.s2 - Y Pha se CT31.s1 - B Pha se CT32.s2 - B P ha se CT

DGM A INS

Micro controller Based Automatic Mains Failure controller unit is most versatile and ragged. It is immune to industrial noise and fluctuation in the supply voltages. It operate [starts, stops] of the DG and monitor the faults, Gauges, Speed [RPM], Frequency, Voltage, Current, KW, KVA, KWH, KVAH, Running Hour and Battery voltage. It switches the load on Mains or load on DG.

Page 4: Web viewproduct brocher . product brocher . table of contained. sr.no

AUTOMATIC MAINS FAILURE CONTROLLER 1-Phase (MODEL: AMF9)

SALIENT FEATURES:

1. AMF Works in 3 modes like AUTO, MANUAL and BY PASS.2. Signal (-ve) input for Mains Sensing.3. Single Phase DG input4. 16 X 2 LCD & LED for Display and status indication.5. Seven inputs for Engine status monitoring (inputs are +ve or –ve active).6. Five out puts for control.7. Out of five, three out puts are Digital i.e. +ve drives for START, STOP and Hooter.8. Two potential free relays contacts for switching Load on Mains or Load on DG.9. Unit Inputs are optically isolated for signals.10. AMF Working on auxiliary power 9vdc to 36vdc.11. Provision of functional keys namely Start, Stop, Set, Up, Down, Acknowledge and

Reset, for Calibration and parameter setting purpose.12. Display DG’s Voltage, Current and frequency.13. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM :

Micro controller Based Automatic Mains Failure controller unit is most versatile and ragged. It is immune to industrial noise and fluctuation in the supply voltages. It operate [starts, stops] the DG and monitor the faults, Frequency, Voltage, Current, Running Hour and Battery voltage. It switches the load on Mains or load on DG.

2

Page 5: Web viewproduct brocher . product brocher . table of contained. sr.no

MULTIFUNCTION ENERGY METER 3-Phase. (MODEL: MF4L)

SALIENT FEATURES: 1. True RMS Digital Energy meter for 3 phase supply.

2. Accuracy better than 0.1%.3. 16x2 / 16x4 lines LCD display for more than 20 screens. .4. CT ratio is digitally settable from 10:5 to 2500:5.5. Inputs are optically isolated for signals.6. Auxiliary power with Cal. 3200 pulses for KWH.7. User pass word code for CT ratio setting and master code for digital calibration

8. RS485 Communication ports 9. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM:

3

Energy meter is multifunction 3-phase true RMS energy meter with 16x2 /16x4 LCD display. It displays the Active, Apparent Power, PF, frequency, voltage, current. Stores KWH, KVAH and Run duration. It has more than 20 screens to select the parameters. The CT ratio is digitally settable from 10 to 2500 amps. User password code for CT ration setting and master code for digital calibration. Applications: 1. Motor, 2. Generator, 4. Mains distribution, etc,.

3

1 2 3 4 5 6 7 8 9S1 S2 S1 S2 S1 S2 NC NC CN

R Y B N NC P N NC NC10 11 12 13 14 15 16 17 18

Page 6: Web viewproduct brocher . product brocher . table of contained. sr.no

4

DUAL SOURCE METER(MODEL: DS4L)

SALIENT FEATURES:

1. True RMS Digital Energy meter for 3 phase Dual Source supply.2. Provision for Duel source.3. S G is source input (sense signal).4. Accuracy better than 0.1%.5. 16x4 lines LCD display for more than 20 screens. .6. CT ratio is digitally settable from 10:5 to 2500:5.7. Optically isolated for Source signal (90 to 300vac).8. Auxiliary Supply voltage 90 to 300vac.9. User passes word code for CT ratio setting and Master code for digital calibration. 10. RS485 Communication ports.11. Panel mounting type cabinet (size: 96x96 x65 mm).

Connection diagram:

KWH METER 1L 5

Dual Source Energy meter is multifunction 3-phase true RMS energy meter with 16x2/16x4 LCD display. It stores KWH and run time in from two different Sources. Displays the Active, Reactive, Apparent Power, PF, frequency, voltage, current. Stores KWH, KVAH and Run duration.It has more than 20 screens to select the parameters. The CT ratio is digitally settable from 10 to 2500 amps. User password code for CT ration setting and master code for digital calibration. Applications: 1. Motor, 2. Generator, 3. Mains distribution, etc,.

Page 7: Web viewproduct brocher . product brocher . table of contained. sr.no

(MODEL: KWH1L)

KWH meter is multifunction 3-phase true RMS with 16x1 LCD display.It displays the Active Power, Apparent Power, PF, voltage, current and frequency, Unit Stores KWH, KVAH and Run Hours.It has more than 10 screens for select the parameters.CT ratio is digitally settable from 10 to 2500 Amps.Provision for user code for CT ratio setting and master password code for digital calibration.Applications:1. Motor 2. Generator 3. Mains distribution, etc..SALIENT FEATURES:

1. True RMS Digital energy meter for 3-phase supply.2. Accuracy better than 0.1%.3. 16*1 LCD display for more than 10 screens.4. Screen Selectable.5. CT ratio is digitally settable from 10:5 to 2500:5.6. Auxiliary supply 230v AC for unit run. 7. User password code for CT ratio setting and Master code for digital calibration.8. Provision for RS485 Communication port.9. Panel mounting type cabinet (size: 96*96*65mm).

CONNECTION DIAGRAM

ENGINE CONTROL SYSTEM (MODEL: ECS-65)

6

1 2 3 4 5 6 7 8 9S1 S2 S1 S2 S1 S2 NC NC NC-- RCT-- -- YCT-- -- BCT--

INPUT AUX R Y B N NC P N NC NC 10 11 12 13 14 15 16 17 18

Page 8: Web viewproduct brocher . product brocher . table of contained. sr.no

Engine control system (ECS65) is most versatile and ragged. It is immune to industrial noise and fluctuation in the supply voltages. It operates [starts, stops] the DG and monitors and displays mains Voltage. Battery charger is controlled by this system. Its inbuilt ATS system switches the load on Mains or on DG. It operates in two modes Auto and Manual.

SALIENT FEATURES:

1. Works in 2 modes like AUTO and MANUAL.2. 3 phase mains input for Line voltage monitor.3. 16 X 2 line LCD & LED for status indication.4. Common fault (Hooter in) (inputs are +ve or –ve active). 5. One relay for start or stop DG, one relay for battery charger (mains phase out put), One

for common fault. 6. Two potential free relays for switching Load on Mains on Load on DG.7. Inputs are optically isolated for signals.8. Working auxiliary power is 9vdc to 24vdc.9. Seven functional keys: Acknowledge Reset, Para, Start and Stop.10. Parameters setting provision.11. Display mains voltage and faults (high/low voltage, phase reversed.), 12. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM:

N1 2 3 4 5 6 7 8 9

10 11 12 13

PM N DG HTINR Y BM AINS

14 15 16 17 18Sp-B +B BAT HTO NO PL NO PL

5.MN load main(opt) .6. DG loa d(from DG)7. DGCom m on fa ult8.P ha se9. Ne utra l

10. -B - BAT -ve11. +B - BAT +ve12 . P ha se fo r cha rge r13. DG sta rt/stop contro lle r14. HT common fault out (+ve)15.NO - NO M a ins16.P L - P ole M a ins17. NO - NO DG18.P L - P ole DG

4.N - Ne utra l

1.R - R P ha se2.Y - Y P ha se3.B - B P ha se

DGM AINSS t

DG

GENERATOR SAFETY UNIT 3-Phase (MODEL: GSU 65E)

7

Page 9: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Works in MANUAL and Remote mode.2. 16 X 2 line LCD & LED for display and status indication.3. Seven inputs monitoring (inputs are +ve or –ve active).4. Out of seven Fuel, Temperature and Pressure Gauges are analog inputs.5. Three +ve Digital out puts for Engine control 6. Inputs are optically isolated for signals.7. Unit working auxiliary power is 9vdc to 36vdc.8. Seven functional keys: Start, Stop, SET, Up, Down Ack and Reset.9. Parameters setting provision.10. Display DG’s frequency, RPM, V&I, KW, KVA, PF, KWH, KVAH & Hour.11. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM:

VAF-H METER

1 2 3 4 5 6 7 8 9

10 11 12 13

FG TG P G TE TP LP ES BP IND

14 15 16 17 18

19202122

2324

-B +B ST S P HT NR Y BDG

s1s2

s1s2

s1s2

CT_Y

CT_B

CT_R

1. FG - Fua l Ga uge2.TG - Tem p. Gauge3.P G - P re ss. Ga uge4.TE - Ta nk Em pty5.TP - High Te m p.6.LP - Low oil P re ss.7.ES - Em e rge ncy stop8.RT - Re m ote 9.IND - Cha rge r10.-B - BAT -ve11.+ B - BAT +ve12.S T - S TART13.S P - S TOP14.HT - Hoote r

18.N - Ne utra l

15.R - R P ha se16.Y - Y P ha se17.B - B P ha se

19.s1 - R P ha se CT20.s2 - R P ha se CT21.s1 - Y P ha se CT22.s2 - Y P ha se CT23.s1 - B P ha se CT24.s2 - B P ha se CT

Generator Safety unit is most versatile and ragged. It is immune to industrial noise and fluctuation in the supply voltages. It operate [starts, stops] the DG and monitor for faults, Gauges, speed [RPM], frequency, Voltage, Current, KW, KVA, PF, KWH, KVAH, Run Hour and Battery Voltage.

Page 10: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Unit Displays 3Phase voltages.2. Displays 3 Phase Line Current.3. Frequency, RPM and Hour meter are displayed on second screen. 4. Back lighted Blue 16x2 LCD display for better reading purpose.5. Provision for digitally settable CT ration from 10:5 to 1000:5.6. Inputs are optically isolated for signals.7. Require Auxiliary power 230V for unit working. 8. Accuracy is better than 0.1 %.9. Panel mounting type cabinet (size: 96x96 x65 mm).

CONNECTION DIAGRAM:

1 2 3 4 5 6 7 8 9S1 S2 S1 S2 S1 S2 NC NC NC-- RCT-- -- YCT-- -- BCT--

INPUT AUX R Y B N NC P N NC NC 10 11 12 13 14 15 16 17 18

VAF- H meter is Digital Voltage, Ampere, Frequency and Hour meter with 16x2 LCD display. It displays 3- Phase volt, Current and Freq. RPM and Hour (run) in scrolling. The CT ratio is digitally settable by using press button (up to 26 sec) on front panel.

Applications: 1. Motor 2. Generator 4. Mains distribution, etc.

Page 11: Web viewproduct brocher . product brocher . table of contained. sr.no

AUTO-TRANSFER SYSTEM-DIGITAL (MODEL: ATS-D)

SALIENT FEATURES:

1. Auto Changeover load from Mains to DG or DG to Mains.2. For Three phase Mains and Single phase DG.3. Provision of the delay setting for mains and DG sensing.4. Protection for single phasing, Phase reversal, High/ Low voltage.5. Displaying Mains voltage R,Y,B and Phase & Neutral for DG.6. Two potential relay for load on Mains and Load on DG.7. Size is 96*96*55 mms. With wall mounting type.

CONNECTION DIAGRAM.

Auto Transfer system (ATS-D) unit is complete Auto change over device with line voltage monitor, Under Voltage, Over Voltage, coil protection and inbuilt timers for smooth trouble free reliable operation. Compact model with wall mounting provision.

APPLICATIONS: 1. Auto-change over for Industrial and domestic purpose.2. DG & multiple powers supply source distributions.

9

1 2P NDG

ADDITIONAL ADDITIONAL DG MAINR2 R1 7 8 9 10

POL

NO

NC

POL

NO

NC

POL

NO

POL

NO

3 4 5 6R Y B N

MAIN

Page 12: Web viewproduct brocher . product brocher . table of contained. sr.no

LINE PROTECTOR UNIT-2(Model: LPU-2)

SALIENT FEATURES:

1. Back light 16x1 LCD display for better displays the system parameters. 2. Unit Displays Voltages & Currents3. CT ratio 1000: 05 amps.4. Provision for High voltage/ Low voltage phasing protection.5. Single phasing protection. 6. Under load and over load protection.7. Setting & control for High/low voltage, over / under load etc. 8. Two independent potential free Relays contacts.9. 96x96x65 panel mounting type.

Line Protective Unit (LPU-2 ) is a unique modern electronics solution for protection of Machinery, Equipment or Motor that has an almost ultimate range of real world applications. It monitors the voltage (High or Low voltage, Phase Reverse, SPP) and current for over load and under load with auto Reset and Load on sense provision.

Application:- Motor, Monitor VAF-Hour, Genset, Equipment and control panelssensing can be disabled.

PARAMETERS DETAILS:-

NC- Of Relay 1P- Of Relay 1NO- Of Relay 1RS1- RCTRS2- RCTYS1- YCTYS2- YCTBS1- BCTBS2- BCT

NC- Of Relay 2P- Of Relay 2NO- Of Relay 2R- Phase Y- PhaseB- PhaseN- PhaseR- Aux. PhaseY- Aux. Neutral

10

Page 13: Web viewproduct brocher . product brocher . table of contained. sr.no

DIGITAL LINE VOLTAGE MONITOR(Model: LVM-PM)

SALIENT FEATURES:

1. Microcontroller based design with digital display.2. Low voltage setting provision from 300v to 400v and break delay.3. High voltage setting provision from 420v to 500v and break delay.4. Hysteresis is used for stability. 5. Phase reversal protections disable/ enable provision.6. Phase unbalance protections disable/ enable provision.7. Faults display like, Low voltage, High voltage, Phase reversal & spp8. Display of voltages (RY, YB and BR Phases).9. Two non potential relays, on healthy.10. Panel mounting. 11. Size 96*96*.

WIRING DIAGRAM:

Digital Line Voltage Monitor is electronic solution for protection of machinery, equipment or motors that has an almost ultimate range of real world applications. It has three independent voltage and phase sensing circuits. The high voltage and low voltage breaking values and delays can be set by using keys on front panel. The phase reversal protection is enabled or disabled.Applications: 1. Equipments protection 2. Motor, 3. Generator 4. Mains distribution, etc.

PARAMETERS DETAILS:-

Hi- High voltage SettingLo: - Low Voltage SettingHbd: - High Voltage Break DelayLbd: - Low Voltage Break DelayPEb: - Phase reverse Protection enablePdb: - Phase reverse Protection disablePtP: - Phase to Phase VoltagePtn: - Phase to Neutral VoltageStd: - Relay Enable delayCry: - R to Y voltage settingCyb: - Y to B Voltage SettingCrb: - R to B Voltage Setting

11

Page 14: Web viewproduct brocher . product brocher . table of contained. sr.no

DIESEL ENGINE STARTER-DIGITAL (Model:DES-D1)

Micro controller based 'Diesel Engine Starter - Digital' controller unit is most versatile and rugged. Its Main function is to maintain the pressure in the Fire-fighting system. Unit starts the Engine-

Pump for maintaining the pressure in the Pressure Chamber. It operate [starts] the DG and monitor for faults like LLOP, Pressure Drop.

SALIENT FEATURES:-

1. 16 X 2 line LCD for status Display.2. Unit having one input for Engine status monitoring (LLOP).3. Controller having one output to start the DG.4. Two non-potential free relay contacts for switching load on Mains or load on

JK(Jack).5. Unit Inputs are optically isolated for signals.6. DES-D works on Auxiliary power of 12V d.c or 24V d.c.7. Panel mounting type cabinet (size: 96*96*65).8. Pressure Drop (PD) input for monitoring pressure in the Fire System Chamber.9. Extra provision for two inputs (MN & JK).10. Relay's potential free outputs (Domain & LD_JK) for other extra applications,

respective with above two extra inputs (MN & JK).11. With Fault reset Key

12. Hooter Provision In case of Fault.

CONNECTION DIAGRAM:-

12

Page 15: Web viewproduct brocher . product brocher . table of contained. sr.no

DIESEL ENGINE STARTER-DIGITAL (Model:DES-D)

Micro controller based 'Diesel Engine Starter - Digital' controller unit is most versatile and rugged. Its Main function is to maintain the pressure in the Fire-fighting system. Unit starts the Engine-

Pump for maintaining the pressure in the Pressure Chamber. It operate [starts] the DG and monitor for faults like LLOP, Pressure Drop.

SALIENT FEATURES:-1. 2 line LCD for status Display.2. Unit having one input for Engine status monitoring (LLOP).3. Controller having one output to start the DG.

4. Two non-potential free relay contacts for switching load on Mains or load on JK(Jack).

5. Unit Inputs are optically isolated for signals.

6. DES-D works on Auxiliary power of 12V d.c or 24V d.c.

7. Panel mounting type cabinet (size: 96*96*65).

8. Pressure Drop (PD) input for monitoring pressure in the Fire System Chamber.

9. Extra provision for two inputs (MN & JK).

10. Relay’s potential free outputs (Domain & LD_JK) for other extra applications, respective with above two extra inputs (MN & JK).

CONNECTION DIAGRAM:-

WATER LEVEL MONITORING UNIT with GSM/GPRS

13

14

Page 16: Web viewproduct brocher . product brocher . table of contained. sr.no

HORIZON ELECTRONIC’S Water Level Monitoring Unit (WLMU) gives the direct measurement of water depth of the submersible pressure sensor. WLMU is having inbuilt power supply of 24 VDC to drive the Ultra sound, submersible pressure, Inductive, Capacitive, Resistive etc., sensor with out put single (4 to 20 mA.) can be connected directly to optically isolated inputs. It also has analog inputs, which can be connected to data loggers. RS232/RS485 communication port with GSM/ GPRS (AT commands) compatible for data collection and transmission.SPECIFICATION:

1. LCD display for indicating water level.2. Analog single (0 to 15vdc/ 4 to 20mA) for data

logger.3. Digital setting for Zero adjustment and calibration.4. RS232/RS485 communication ports with GSM/ GPRS compatible. 5. Inbuilt power supply (24Vdc) for the excitation of the transducer.6. Input is optically isolated for 4 to 20 mA signal.7. Works on 230Vac power and 24 DC battery.8. Measuring ranges are 0 to 999 mm; 0 to 999 cm and 0 to 999 mt.

DEMO PHOTO

GENERATOR SAFETY UNIT(MODEL NO:GSU)

15

Page 17: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. 16 X 2 line LCD for status indication.2. Five optically isolated fault signal inputs (-ve active).3. Two +ve outputs, for START and STOP.4. Bar gauge for Fuel, Temperature and Oil pressure.5. LED indications for “Run” and “Faults”6. Protection against Faults, over / under speed and No voltage.7. Auxiliary Supply 9 to 36 v dc.8. Panel mounting type cabinet (size 96x96 x85 mm).

CONNECTION DIAGRAM:

ENGINE SAFETY UNIT(MODEL: SU-01)

Generator Safety Unit is rugged and immune against industrial noise. It is designed for trouble free functioning even in extreme environmental conditions. It monitors DG voltage, current, frequency, speed [RPM], and battery voltage. It has 5 fault signal inputs and also provides protection against under speed and over speed (RPM < 1350 & > 1650). Level gauge for Fuel level, Temp. and Oil pressure. Protects against false cranking when DG is ON.

16

Page 18: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Microcontroller based design.2. Five faults sensing by –ve switches are optically isolated.3. Stop solenoid ON for 20 sec. on removal of Enable. 4. Hooter on Faults, driven by –ve (optional).5. 8mm LED indication on Faults and fuse fail. 6. STOP solenoid relay of 70 amps, with reverse current suppression circuits.7. 72mm x 72mm basil and 68mm x 68mm cutout panel mounting.

WIRING DIAGRAM:

ENGINE CONTROL PANEL (MODEL: ECP)

Engine Safety Unit (SU-01) is electronic solution for protection of Engines.It has six independent faults sensing circuits and LED indications on front panel.Faults switch inputs are optically isolated. It has rigid design so it functions with out problem even in adverse environments’.

Page 19: Web viewproduct brocher . product brocher . table of contained. sr.no

Engine control panel (ECP) is rugged and immune against industrial noise. It is design for treble free even in extreme environment condition.ECP is to SART/and STOP engine, DG, protection against fault, display of battery voltage and current, ac voltage of DG, RPM , HOUR METER , type of faults, and gauges for fuel level, temperature and oil pressure.

SALIENT FEATURES:

1. Start /stop provision with key and press button. Protected against false crank, if DG is ON. If start button pressed and hold more than 5 sec., start solenoid will be released.

2. LCD display for battery voltage, charging current, Hour meter, Ac voltage, RPM, Faults etc.,.3. LED indication for RUN, Remote stop, High temperature, Low oil pressure, Low Radiator

water level, Charger fault, Emergency stop and Low fuel level.4. Faults protection for Over speed & under speed, No voltage (DG alternator fail), High

temperature, Low oil pressure, Low Radiator water level, Emergency stop and Low fuel level.

5. Relay card with start & stop relays of 70 amps. contacts, non potential relay for LOP (pole & NC), LFL(pole &NO), Battery charger alternator excitation current relay, Timer relay for battery power saving which make ECP power off, 1 minute after ECP made Off.

6. Provision for remote start, remote stop and interface controller like AMF, Auto changeover etc.

7. Panel mounting type cabinet (size 192x96 x65 mm).

CONNECTION DIAGRAM:

AUTO-TRANSFER SYSTEM 3-Phase (Model: ATSC)

12V

DCM

STO

P S

OV

LLO

P S

W

HW

T S

W

RW

L S

W

CH

AOP

S

WTS

FLS

E.S

TOP

LFL

SW

A LTE RNA TORENG

INE

START

STOP

CHA+

BAT+ve

BAT-ve

1 2 3 4 5 6 7 8 9 10 11 12 13 14

15 16 17 18 19 20 21 22 23 24 25 26 27 28

RU

N

HW

T

LOP

RW

L

IND

E.ST

OP

LFL

FLG

TLG

PLG

BA

T+ve

BA

T-ve

CR

I

R.S

TOP

LOP-

CM

LOP-

NC

LFL-

CM

LFL-

NO

RLY

-CM

RLY

-NO

Neu

tral

Phas

e

Engine C ontrol Panel

1. RUN : Remote ON of the ECP

2. HWT : High Tempareture

3. LOP : Low Oil P ressure

4. RWL Radiator Water Level

5. IND Charger Fault

6. E .STOP : Emergency Stop

7. LFL : Low Fuel

8. FLG : Fuel Level Gauge

9. TLG : Temperature Level Gauge

10. PLG : Pressure Level Gauge

15. BAT+ve: Battery +ve for remote unit like AMF

17. CRI : Remote Crank in (Remote START)

18. R.STOP : Remote STOP

19. LOP_CM : LOP Relay common

20. LOP_NC : LOP Relay NC

21. LFL _CM : LFL Relay common

22. LFL_NO :LFL Relay NO

23. RLY_C M : Auto EC P OFF Relay

24.Neutral : Neutral of DG alternator

16. BAT-ve: Battery -ve for remote unit like AMF

23. RLY_NO : Auto EC P OFF Relay

25. Phase : Phase of D G alternator

1

2

3

4

5

1. START : Start solenoid of D G

2. STOP : S top solenoid of DG

3. CH A+ : CH ARGER for Amp. reading

4. BAT+ve: B attery +ve

5. B AT-ve: Battery -ve

Auto Transfer system (ATS) unit is complete Auto change over device with line monitor, coil protection, overload

18

Page 20: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains), (5sec. For DG).3. Protection for single phasing, Phase reversal, High/ Low voltage.4. Over load setting provision.5. Indications for Mains RYB, DG RB& over load protection.6. Auto changeover up to 64 amps. Available in this model.7. Size is 220x180x130 mms. With wall mounting type.

CONNECTION DIAGRAM:

AUTO-TRANSFER SYSTEM 3-Phase (Model: ATSR)

Auto Transfer system (ATS) unit is complete Auto change over device with line monitor, coil protection,

18

TC 1-D 25004Autoch an geover w ith O ver load Relay Un it

R Y B N R Y B NR Y B N R Y B N

M AINSD.G. OUTPUT

1. Mains timer for 2 sec.2. High and low voltage protection.3. Hysteric's used for antichattering.4. D . G. Timer for 5 sec.5. Over load protection with auto_restart.6. E lectrical interlocking

F unc tio ns :

C T

CT

C T

A1

A2

A1

A2

D.G. C ontactor MA INS Contactor TC 1-D40004

1 2 3 4 5 6 7 8 9 10

Auto Transfer system (ATS) unit is complete Auto change over device with line monitor, coil protection, overload

Page 21: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains), (5sec. For DG).3. Protection for single phasing, Phase reversal, High/ Low voltage.4. Over load setting provision.5. Indications for Mains RYB, DG RB& over load protection.6. Auto changeover up to 64 amps. Available in this model.7. Size is 220x180x130 mms. With wall mounting type.

CONNECTION DIAGRAM:

LINE VOLTAGE MONITOR DIGITAL(MODEL: LVMD-3)

Auto Transfer system (ATS) unit is complete Auto change over device with line monitor, coil protection,

TC 1-D 25004Autoch an geover w ith O ver load Relay Un it

R Y B N R Y B NR Y B N R Y B N

M AINSD.G. OUTPUT

1. Mains timer for 2 sec.2. High and low voltage protection.3. Hysteric's used for antichattering.4. D . G. Timer for 5 sec.5. Over load protection with auto_restart.6. E lectrical interlocking

F unc tio ns :

C T

CT

C T

A1

A2

A1

A2

D.G. C ontactor MA INS Contactor TC 1-D40004

1 2 3 4 5 6 7 8 9 10

19

Page 22: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:12. Microcontroller based design with digital display.13. Low voltage setting provision from 300v to 400v and break delay.14. High voltage setting provision from 420v to 500v and break delay.15. Hysteresis is used for stability. 16. Phase reversal protections disable/ enable provision.17. Faults display like, Low voltage, High voltage & Phase reversal. 18. Display of voltages (RY, YB and BR Phases).19. Two non potential relays, on healthy.20. DIN rail and panel mounting.

WIRING DIAGRAM:

OVER LOAD RELAY(MODEL:ORT-1P & 3P)

Over Load Relay (ORT-3) is a unique modern electronic solution for protection of machinery, equipment or motors that has an

Digital Line Voltage Monitor (LVMD-3) is electronic solution for protection of machinery, equipment or motors that has an almost ultimate range of real world applications. It has three independent voltage and phase sensing circuits. The high voltage and low voltage breaking values and delays can be set by using keys on front panel. The phase reversal protection is enabled or disabled.Applications: 1. Equipments protection 2. Motor, 3. Generator 4. Mains distribution, etc.

20

Page 23: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Three phase current sensing.2. Over load setting provision from 40% to 130 % (100% =5 amp.) 3. Break delay setting provision from 0 to 12 seconds.4. Indications for power ON, pick up and Trip.5. Power supply 9 V dc to 28 V dc.6. Non potential relay, switch’s only on Break.7. DIN rail and panel mounting.

WIRING DIAGRAM:

AUTO CHANGEOVER CUM CURRENT LIMITER (MODEL: ACCL-PTC)

Over Load Relay (ORT-3) is a unique modern electronic solution for protection of machinery, equipment or motors that has an

21

Page 24: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains) and (5sec. For DG).3. Over load setting provision (0.2 to 40A).4. Indications for Mains ON, DG ON and Over load protection.5. Auto Reset for over load (10 sec).6. Power supply (120v to 300v).7. Panel mounting type, size: L=11cm, W=12cm, D=7.5cm.

WIRING DIAGRAM:

AUTO-TRANSFER SYSTEM CONTROLLER.(Model: ATSC PTC)

Auto-Changeover unit is a unique modern electronic solution for Automatic changeover of the load from Mains to DG and vice versa along with the over load protection. Over load setting provision is available from (0.2 to 40A) for DG.

APPLICATIONS: 1. Auto-change over for Industrial and domestic purpose.2. Over load protection.

22

Page 25: Web viewproduct brocher . product brocher . table of contained. sr.no

Auto changeover system control unit is complete control device with line monitor, coil protection, overload protection and timers inbuilt for smooth trouble free reliable operation of Auto changeover system. Using this unit Auto changeover system of any range can be built with minimum wiring.APPLICATIONS: 1. Auto-change over for Industrial and domestic purpose.2. DG & multiple powers supply sour distribution

SALIENT FEATURES:

1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains), (5sec. For DG).3. Protection for single phasing, Phase reversal, High/ Low voltage.4. Over load setting provision.5. Indications for Mains ON, DG ON & over load protection.6. Auto Restart for over load (10 sec).

7. Using this unit, Auto changeover of any range can be built.

CONNECTION DIAGRAM:

AUTO-CHANGEOVER CUM CURRENT LIMITER.(ACCL-DINRAIL)

23

MAINS DG DG MN R Y B N P N P

OUTPOUT

1 2 3 4 5 6 7 8

Page 26: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Mainly Unit is for Single phase Mains and DG operation2. Auto Changeover from DG to Mains.3. In built delay (2 sec. For mains) and (5sec. For DG).4. Over load setting provision (0.2 to 30A).5. Indications for Mains ON, DG ON & over Load protection.6. Auto Reset for over load (10 sec).7. Power supply (120v to 300v).8. Din Rail mounting, Size 110mm x 72mm x 60mm

WIRING DIAGRAM:

AUTO TRANSFER SYSTEM CONTROLLER (MODEL: ATSC-DIN)

Auto changeover system control unit is complete control device with line monitor,

Auto-Changeover unit is a unique modern electronic solution for Automatic changeover of the load from Mains to DG and vice versa along with the over load protection. Over load setting provision is available from (0.2 to 40A) for DG.

APPLICATIONS: 3. Auto-change over for Industrial and domestic purpose.4. Over load protection.

24

Page 27: Web viewproduct brocher . product brocher . table of contained. sr.no

TC1-D25004Autochangeover with Over load Relay Unit

R Y B N R Y B NR Y B N R Y B N

MAINSD.G. OUTPUT

1. Mains timer for 2 sec.2. High and low voltage protection.3. Hysteric's used for antichattering.4. D. G. Timer for 5 sec.5. Over load protection with auto_restart.6. Electrical interlocking

Functions:

CT

CT

CT

A1

A2

A1

A2

D.G. Contactor

MAINS Contactor TC1-D40004

1 2 3 4 5 6 7 8 9 10

SALIENT FEATURES:

1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains), (5sec. For DG).3. Protection for single phasing, Phase reversal, High/ Low voltage.4. Over load setting provision.5. Indications for Mains ON, DG ON & over load protection.6. Auto Restart for over load (10 sec).7. Using this unit, Auto changeover of any range can be built.

CONNECTION DIAGRAM:

AUTO-CHANGEOVER CUM CURRENT LIMITER(MODEL: ACCL-3PH)

Auto changeover system control unit is complete control device with line monitor,

25

Page 28: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Auto Changeover from Mains to DG & DG to Mains.2. In built delay (2 sec. For mains), (5sec. For DG).3. Over load setting provision (0.2 to 40A).4. Indications for Mains ON, DG ON & Over load.5. Auto Restart for over load (10 sec).6. Power supply (120v to 300v).7. Base plate mounting provision.8. Din rail mounting provision.9. Panel mounting type, size: L=110mm, W=70 mm, D=115mm

CONNECTION DIAGRAM:

SINGLE PHASE PREVENTOR (MODEL: SPP)

26

Auto-Changeover unit is a unique modern electronic solution for Automatic changeover of the load from Mains to DG and vice versa along with the input supply available with over load protection.Over load setting provision is available from (0.2A to 40A) for DG.Unit is for 3-Phase DG and 3-Phase mains as well as 3-Phase Mains and 1-Ph DG any kind of the combination for DG and Mains can be apply.APPLICATIONS:

5. Auto-change over for Industrial and domestic purpose.6. Over load protection.

Page 29: Web viewproduct brocher . product brocher . table of contained. sr.no

SALIENT FEATURES:

1. Works on 3 phase R Y B inputs.2. 2 seconds start delay after healthy supply input.3. Phase to Phase imbalance 40 v.4. Phase reversal protection. 5. Voltage hysteresis is used for stability.6. Voltage Healthy LED indication. 7. One potential relays, NO on healthy.8. Panel mounting.

WIRING DIAGRAM: R Y PHASE B NC OF RELAY POL OF RELAY NO OF RELAY

R Y B NC POL NO

Single Phase Preventer (SPP-3) is electronic solution for protection of machinery, equipment or motors that has an almost ultimate range of real world applications. It has three independent voltage and phase sensing circuits. It gives protection against Phase to Phase imbalance, single phasing and phase reversal.Applications: 1. Equipments protection. 2. Motor,3. Generator, 4. Mains distribution, etc,.

HEALTHY

Page 30: Web viewproduct brocher . product brocher . table of contained. sr.no

AUTO-TRANSFER SYSTEM-DIGITAL MODEL NO: ATSD

Auto Transfer system (ATS-D) unit is complete Auto change over device with line voltage monitor, Under Voltage, Over Voltage, coil protection and inbuilt timers for smooth trouble free reliable operation. Compact model with wall mounting provision.

FEATURES:

1. Auto Changeover load from Mains to DG or DG to Mains.

2. For Three phase Mains and Single phase DG.3. Provision of the delay setting for mains and DG

sensing and one extra additional relay.4. Protection for single phasing, Phase reversal, High/ Low voltage.5. Displaying Mains voltage R,Y,B and Phase & Neutral for DG.6. Two potential relay for load on Mains and Load on DG.7. Size is 96*96*55 mms. With wall mounting type.

BACK CONNECTION DIAGRAM:

PARAMETERS:-

1. oV –High Voltage setting (470V) 2. uV- Low Voltage setting (320V) 3. oVd- High Voltage Break Delay (5 Sec) 4. uVd- High Voltage Break Delay (5 Sec) 5. rP- Phase Reverse YES- Phase Reverse Enable no- Phase Reverse Disable 6. PtP- Phase to Phase Voltage 7. Ptn- Phase to Neutral Voltage 8. dLY- Unit Start Delay (5 Sec)

9. CrY- R to Y Phase Voltage Calibration 10. CYb- Y to B Phase Voltage Calibration 11. Cbr- B to R Phase Voltage Calibration 12- unb- Unbalances Voltage (80V) 13. LdP- Load on Mains (3 Sec) 14. Ldd- Load on DG (5 Sec) 15. dg on- Generator on.

WATER LEVEL CONTROLLER

27

26

1 2 3 4 5 6 7 8 9MNC MP MNO GNC GP GNO NC NC NC

MAINS D.G CONTACTOR CONTACTOR

MAINS 3 PHASE D.G

MR MY MB MN NC NC NC GR GN10 11 12 13 14 15 16 17 18

Page 31: Web viewproduct brocher . product brocher . table of contained. sr.no

(MODEL: WLC-1)

Horizon electronics WLC is an electronic switch for motor. It automatically switch on/off motor to maintained the water level in the tank and gives complete protection to the motor. Electronic water level controller consisting of electronics devices with 5 sensor probe, one dry running probe. Three sensor for sump thank and other for over head tank. Three sensor probe continuously monitor the water level in sump tank as well as the over head tank

SISLENT FEATURES:1. No manual operation is required.2. Restart is provided to start motor manually.3. Advanced Digital Technology.4. Prevent dry running.5. Auto/ Manual control.6. Auto/ Visual indication of the status.7. Easy to install8. No overflow of water from tank.9. Prevent reserve water level in both tank.

CONNECTION DIAGRAM:

COMMON

DRY RUM

SUMP RESERVE

TANK UP

TANK RESEVE

SUMP UP

P NMAINS

P N MOTOR

Page 32: Web viewproduct brocher . product brocher . table of contained. sr.no

28

OTHER PRODUCTS

Sr. No. PRODUCTS1 Speed Meter2 ELSU3 SPST(Krish)4 MPU (Motor Protector Unit)5 Home Protector (HP-97)6 Safe Guard7 MSPS 1P8 Coil Protector9 Water Level Controller (WLC-1)10 Water Level Controller (WLC-2)11 Water Level Controller (WLC-3)12 Water Level Controller (WLC-1SL)13 Water Level Controller (WLC-3SL)14 Water Level Controller (WLC-2SL)15 Water Level Controller (WLC-1 ID)16 Water Level Controller (WLC-1P)17 Dental Chair Controller18 Master Safe19 MSPS-3P20 2-Channel Relay Card (12V)21 2-Channel Relay Card (24V)22 4-Channel Relay Card 23 4-Channel Relay Card (ASM)24 5-Channel Relay Card 25 6-Channel Relay Card 26 Gsu-01