- o2 airconditioning · 181 barbara road elandsfontein ... - with a temperature sensor controlling...

14
For continual product development, LG reserves the right to change specifications without notice. © LG Electronics Inc. Printed in Korea 2006 S.A-CA071 LG Air Conditioning 2007 We always pursue highly advanced technologies to improve the quality of your life. Enjoy a clean, quiet & comfortable life with LG Air Conditioners. www.lge.co.za 181 BARBARA ROAD ELANDSFONTEIN P.O.BOX 473. ISANDO 1600, SOUTH AFRICA Phone : 27 11 571 6700 http://www.lge.co.za

Upload: nguyentruc

Post on 21-May-2018

253 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

For co

ntin

ual p

rod

uct d

evelop

men

t, LG reserves th

e righ

t to ch

ang

e specificatio

ns w

itho

ut n

otice.

© LG

Electron

ics Inc. Prin

ted in

Ko

rea 2006

S.A-CA071

LG Air Conditioning 2007We always pursue highly advanced technologies to improve the quality of your life.

Enjoy a clean, quiet & comfortable life with LG Air Conditioners.

ww

w.l

ge

.co

.za

181 BARBARA ROAD ELANDSFONTEINP.O.BOX 473. ISANDO 1600, SOUTH AFRICAPhone : 27 11 571 6700http://www.lge.co.za

Page 2: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

LG Electronics, The World’s Best Seller,Seven Years in a Row

World-renowned cooling appliance and airconditioner magazine JARN has selected LG as theNo. 1 Seller for SEVEN consecutive years. LG believesthat its achievement is the result of giving theconsumers nothing but the best. LG promises tocontinue to innovate itself and move forward.

HIDE-AWAY TYPE 06

CONTENTS

SINGLE PACKAGED TYPE 16

DUCTED SPLIT TYPE 24

Page 3: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

Models _ Line up The World’s Number 1 Choice in Air Conditioners!

Single Packaged Type Ducted Split Type

Btu/h

3~6tons 7.5~30tons 3~5tons 7.5~10tons 12.5~20tons

18,000 24,000 30,000 36,000 42,000 48,000 60,000 72,000 100,000 120,000

Hide-Away Type

Single Split Mid-Wall Type

Window Type

Ceiling Cassette Type

Floor Standing Type

Underceiling Type

18,0007,000Btu/h 9,000 12,000 18,000 22,000 24,000 26,000 30,000 36,000 48,000 60,000 72,000 80,000

Page 4: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

HIDE-AWAY TYPEHidden in the ceiling, this model is designed for buildings that require floor level air conditioning for manyindividual rooms or large areas, like restaurants, concert halls and hotels. Installation is not restricted bylighting fixtures or the building layout, and interior renovation is made easy by installing ventilation diffusers.

Hid

e-A

wa

y T

yp

e

06

07

LG AIR CONDITIONERS 2007

*E.S.P: External Static PressureThe air volume and sound level is kept constant as designedregardless of changes in E.S.P.(External Static Pressure)E.S.P. technology - Optimizes Duct Installation- Keeps Capacity & Sound Levels within desired ranges- Reduces the number of modelsPhase control motor technology reduces installation costs.The desired air flow is obtained by adjusting the phasemotor during installation of the product, giving you moreflexibility when setting up your duct system. The E.S.P canbe adjusted linearly from 0 to 10mmAq.

PLASMA Air Purifying System (Optional)The integrated PLASMA Air Purifying System removesmicroscopic contaminants and dust, eliminates offensiveodors and prevents allergic reactions. It can also be used asan air-purifying unit only, without running the airconditioner.

Hide-Away Type

Evaluated by CSIRO Australia (DBCE Doc 98/204)

Tested by Korean Food Research Institute and Japanese Environmental Centre and

Yonsei Univ. College of Medicine. (Allergy Research Lab.)

Respirable particles from 5 cigarettes in a sealedroom removed by the LG Plasma Air PurifyingSystem.

LG's Plasma Air Purifying unit effectively removeshigh concentrations of tobacco odors (Confirmedin sensory tests carried out in Korea and Japan.)

In clinical tests, the LG Plasma Air Purifying Systemreached a satisfaction level of 82% .

> Dust Reduction

> Deodorization

> Anti-Allergy

Page 5: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

Hid

e-A

wa

y T

yp

e

08

09

LG AIR CONDITIONERS 2007

Hide-Away Type

Long Distance Piping High ElevationLG Air Conditioners (Cassette and Duct-type models) can beinstalled at long distances (max 50m) and high heightdifferences (30m) from the outdoor unit.

Plz refer to the picture below.

Zone Controller (Optional)1) Basic Operation

- With a temperature sensor controlling every diffuser,the temperature for each zone can be monitored andadjusted automatically.

2) Control Features- If every damper is closed, the compressor and outer fan

are turned off, to protect the compressor.

Central Controller (Option)1) Basic Operation

-Linking several units, one Central Control Unit canmanage and turn off several units individually or as agroup.

2) Control Features - Each indoor unit is connected to a Central Control Unit

via a data communication cable and can be operated orturned off individually or together with a group of unitswith the central controller.

- The Central Control Unit can manage up to 8 * 16 indoorunits.

Zero standby power consumption- Eliminates waste of electricity in standby mode.- Electricity is wasted when an appliance is connected to an

outlet, even though the appliance is turned off. - Development of a super power-saving SMPS (Swiching

Mode Power Supply)- Minimal standby power consumption (90% reduction of

standby power).- No need to pull the main power plug when the appliance

is not in use.

Auto ChangeoverNeed not control on each times at big diurnal range areas.

Two Thermistor ControlThe dual thermistor control regulates the differencebetween the indoor temperature and the temperature ofthe conditioned air by monitoring both temperatures, toensure a uniform room temperature. The sensor readingsare adjusted for optimum room temperature.

Heating

Dehumidifying

Cooling

Micro Processor

Analyze 3 Temperature

Measure Periodically

Target Temperature

Outdoor Temperature

Indoor Temperature

High Head Drain Pump (Optional)The High Head Drain Pump pumps water up to 700mm highfor smooth drainage.

Pipe fixture

FlexibleDrain Hose

Drain pump

Wall

Drain pipe

700mm

50m 30m

Timer-controlled OperationIf desired, you can set operation times for up to one week inadvance.

LCD Wired Remote Controller

• 24-Hour ON/ OFF Timer with 1 hour intervals

• TEST RUN Mode

• Self-Diagnosis feature

• 3-Step Fan Speed selection

• Operation Indicator

• Room Temperature Display

• Only 20mm thick

OptionWireless Remote controller

Zone A

Zone C

Zone D

Zone B

On Off

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16

1 2 16

Controller#1

Controller#2

On Off

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16 Controller#8

On Off

1 2 3 4

5 6 7 8

9 10 11 12

13 14 15 16

1 2 16

Gold Fin™ Anti CorrosionLG’s Outdoor Heat Exchanger is coated with a gold-coloredanti-corrosive epoxy treatment on the aluminum coil, toprevent corrosion. This maintainsexcellent heat transferproperties of the coil for an extended time, whereas non-Gold FinTM coils progressively lose efficiency due to surfacecorrosion. Gold FinTM fin is perfect for areas with highpollution or locations exposed to saltwater spray from thesea.

Gold Coated Aluminum Uncoated Aluminum

LG Gold Fin™Corrosion Free

ConventionalStarting to corrode

After 15 Days After 15 Days

Salt Spray Test for 15 Days

Group Control1) Basic Operation

- Linking several units, one Group Control Unit canmanage a number of indoor units.

2) Control Features- Through a data cable connected to each indoor unit, a

group of units can be managed from the groupcontroller.

- The Group Control function is enabled by cutting anoptional jump wire in the wired remote control, whichprevents data collision.

- One Group Control Unit can control up to 16 indoorunits.

2 16........

........

Page 6: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

Hid

e Aw

ay Type

• LB-H1208VA0

Features

• Weekly Program • Auto Changeover • Two Thermistor Control

• Group Control • 24-Hour ON/OFF • Child Lock Function

• Auto Restart • Anti Corrosion Gold FinTM(Outdoor)

• Central controller(Optional)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

Less NoiseThe product has considerably less noise levelinside resulting from changing to the direct-drive method from the pre-established pulleymethod of the blower and the motor.

Convenience in Installation(convertible flow)You can adjust the air flow either vertically orhorizontally depending on the characteristicsof the space where it's installed.

• High efficiency, less noise, lowenergy intake, fresh air intake

• An invertible fan motor has beeninstalled.

• The air volume can be controlledby the wired remotecontroller.(0~20mmAq)

Conventional_Pulley

→ →New_Direct Drive

75dB LB-H1208VA0Model

Capacity

Cooling Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

Power Input. Cooling / Heating Watt

Running Current Cooling / Heating A

Performance

EER Cooling Btu/hr.W

COP Heating W/W

Air Circulation Indoor m3/min

Moisture Removal l /hr

Noise Level Indoor(H/M/L) dB(A)±3

Outdoor Max dB(A)±3

External Static Pressure mmAq

Cable Main No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)

Installation & Stuffing

Net Dimensions Indoor mm

(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kg

Stuffing Quantity With S/Parts 20/40ft

Without S/Parts 20/40ft

Service Valve Liquid/Gas ø(mm)

Specification

120,000)

132,000

380~415,50/3

15,000 / 13,000

24/21

8.0(2.34)

10.8(3.15)

105

10

53

65

0~20

5*8.5

6*1.25

1,700x712x837

1,280x1,520x730

130/300

-

6/14

15.88/28

10 11

• LB-H1860BS1 / • LB-H2460BS1• LB-H306GSS0 / • LB-H366GSS0

Features

• Long Distance, High Elevation • Weekly Program • Standby Power Zero

• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart

• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)

• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)

• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

LB-H306GSS0

30,000

30,000

220~240.50/1

3,150/2,600

14/12

9.5

3.38

26.5/23/20

3.00

40/38/36

56

10

3*3.5

5*0.75

1,180x298x450

870x655x320

38/64

32/70

36/74

6.35/15.88

LB-H366GSS0

36,000

36,000

220~240.50/1

4,000/3,300

18.5/15.5

9.0

3.2

32/29/26.5

3.5

42/40/38

56

10

3*5.5

5*0.75

1,180x298x450

870x808x320

38/66

32/70

36/74

6.35/15.88

LB-H1860BS1

18,000

18,000

220~240.50/1

2,000/1,880

10.0/9.5

9.0

2.8

16.5/14.5/13

2.00

36/34/32

55

8

3*2.5

6*0.75

880x260x450

870x655x320

34/57

42/94

48/101

6.35/15.88

LB-H2460BS1

24,000

24,000

220~240.50/1

2,650/2,400

12.5/11.3

9.1

2.93

18/16.5/14

2.50

37/35/33

55

8

3*2.5

6*0.75

880x260x450

870x655x320

35/60

42/94

48/101

6.35/15.88

Model

Capacity

Cooling Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

Power Input. Cooling / Heating Watt

Running Current Cooling / Heating A

Performance

EER Cooling Btu/hr.W

COP Heating W/W

Air Circulation Indoor(H/M/L) m3/min

Moisture Removal l /hr

Noise Level Indoor(H/M/L) dB(A)±3

Outdoor Max dB(A)±3

External Static Pressure mmAq

Cable Main No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)

Installation & Stuffing

Net Dimensions Indoor mm

(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kg

Stuffing Quantity With S/Parts 20/40ft

Without S/Parts 20/40ft

Service Valve Liquid/Gas ø(mm)

Specification

• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy ofinnovation some specificationsmay be changed withoutnotification.

Page 7: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

Hid

e-Aw

ay Type

• LB-M7280BS / • LB-M1080BS

Features

• Long Distance, High Elevation • Weekly Program • Standby Power Zero

• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart

• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)

• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)

• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

• LB-H368GSS0 / • LB-H428GSS0• LB-H488RSS0 / • LB-H608RSS0

Features

• Long Distance, High Elevation • Weekly Program • Standby Power Zero

• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart

• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)

• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)

• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

12 13

LB-H368GSS0

36,000

36,000

380~415.50/3

4,000/3,300

7.2/6.3

9.0

3.2

32/29/26.5

3.50

42/40/38

58

10

4*2.5

5*0.75

1,180x298x450

870x808x320

38/66

32/70

36/74

6.35/15.88

LB-H428GSS0

42,000

42,000

380~415.50/3

4,350

7.3

9.6

10.24

32/29/26.5

5.00

42/40/38

60

10

5*2.5

5*0.75

1,180x298x450

900x1,130x370

38/93

27/55

27/55

9.52/19.05

LB-H488RSS0

48,000

48,000

380~415.50/3

5,500/4,500

9.0/8.0

8.7

3.13

45/40/35

6.00

49/47/45

62

10

4x3.5

5x1.25

1,230 x 380 x 590

900 x 1,130 x 370

53/93

22/51

24/51

9.52/19.05

LB-H608RSS0

57,000

60,000

380~415.50/3

6,150/4,900

10.5/8.5

9.3

3.6

50/45/40

6.5

49/47/45

62

10(Max15)

4x3.5

5x1.25

1,230 x 380 x 590

900 x 1,130 x 370

53/93

22/51

24/51

9.52/19.05

Model

Capacity

Cooling Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

Power Input. Cooling / Heating Watt

Running Current Cooling / Heating A

Performance

EER Cooling Btu/hr.W

COP Heating W/W

Air Circulation Indoor(H/M/L) m3/min

Moisture Removal l /hr

Noise Level Indoor(H/M/L) dB(A)±3

Outdoor Max dB(A)±3

External Static Pressure mmAq

Cable Main No.*(mm2)*Max L.(m)

Conneting No.*(mm2)*Max L.(m)

Installation & Stuffing

Net Dimensions Indoor mm

(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kg

Stuffing Quantity With S/Parts 20/40ft

Without S/Parts 20/40ft

Service Valve Liquid/Gas ø(mm)

SpecificationSpecification

LB-M7280BSModel

Capacity

Cooling Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

Power Input. Cooling / Heating Watt

Running Current Cooling / Heating A

Performance

EER Cooling Btu/hr.W

COP Heating W/W

Moisture Removal l /hr

Installation & Stuffing

Net Dimensions Indoor mm

(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kgs

Service Valve Liquid/Gas ø(mm)

72,000

72,000

380~415.50/3

7,000/6,800

13/13

10.3

3.1

5.86

1,416 x 400 x 575

1,245 x 930 x 650

58/185

12.7/25.4

LB-M1080BS

100,000

104,000

380~415.50/3

10,500/8,700

17.0/14.7

9.5

3.5

6.30

1,696 x 450 x 658

1,245 x 930 x 650

88/195

15.88/28.6

• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification.

Note :Due to our policy of innovation some specifications may be changed without notification.

Page 8: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

Hid

e-Aw

ay Type

• UB36 / • UB42 / • UB48 / • UB60

Features

• Weekly Program • Auto Changeover • Two Thermistor Control

• Group Control • 24-Hour ON/OFF • Child Lock Function • Auto Restart

• Hot Start (Heat pump Model) • Anti Corrosion Gold Fin(Outdoor)

• Zone Control(Accessory) • Central controller(Accessory)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

• UB18 / • UB24 / • UB30

Features

• Weekly Program • Auto Changeover • Two Thermistor Control

• Group Control • 24-Hour ON/OFF • Child Lock Function • Auto Restart

• Hot Start (Heat pump Model) • Anti Corrosion Gold Fin(Outdoor)

• Zone Control(Accessory) • Central controller(Accessory)

Hide-Away Type

24-Hour OFFSetting Timer

24Child Lock Group

Controller

14 15UU18W UU24W UU30W

Model

Compressor(Inverter) TypeCompressor(Constant) TypeRefrigerant Charge Charge g(oz)

TypeFan Discharge Side/TopNoise Level Sound Press, 1m dB(A)±3Pipe Connection Liquid inch(mm)

Gas inch(mm)

Dimensions WxHxD inch(mm)

Net Weight Outdoor kg(lbs)Power Supply Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2Max. Piping Length/Elevation mPower Supply ø,V, HzStuffing Quantity Without S/Parts 20/40ft

UU18W

e-Scroll-

1500(52.91)R410A

Side Discharge51/45

1/4 (6.35)1/2 (12.7)

34.3*25.8*12.6 (870*655*320)

52(115)3*2.5

4*0.7540/30

1,220-240,50

81/171

UU24W

e-ScrollRotary

1750(61.72)R410A

Side Discharge52/46

1/4 (6.35)1/2 (12.7)

34.3*31.5*12.6 (870*800*320)

69(152)3*2.5

4*0.7550/30

1,220-240,50

54/114

UU30W

e-ScrollRotary

2100(74.07)R410A

Side Discharge50/46

1/4 (6.35)5/8 (15.88)

34.3*41.7*12.6 (870*1060*320)

80(176)3*2.5

4*0.7550/30

1,220-240,50

51/111

Indoor Unit _

Note :Due to our policy of innovation some specifications may be changed without notification.

Outdoor Unit _

Model

Cooling Btu/hCapacity W(Min~Rating~Max) Heating Btu/h

WInput Cooling W(Min~Rating~Max) Heating WE.E.R W/WC.O.P W/WRunning Current Cooling/Heating APower Supply ø,V, HzSetting Temperature Cooling °CRange(Indoor) Heating °COperational Temperature Cooling °CRange(Outdoor) Heating °CAir Flow Rate H/M/L CMM(CFM)External Static Pressure mmAqNoise Level(SoundPress,1m) H/M/L dB(A)±3Dehumidification Rate I/h

Dimensions (WxHxD) inch(mm)

Net Weight kg(lbs)Stuffing Quantity Without S/Parts 20/40ft

UB18

6,840~18,000~21,6002,006~5,275~6,329

7,714~20,300~24,8402,261~5,949~7,280623~1,640~2,370627~1,650~2,370

11.03.61

2.3~7.5/3.5~10.61,220~240,50

18~3016~30-10~43-15~24

16.5/14.5/13(583/512/459)8

36/34/322.0

34.6x10.2x17.7(880x260x450)

35(77.2)

120/252

UB24

9,120~24,000~28,8002,671~7,034~8,440

10,488~27,600~32,0003,074~8,089~9,376832~2,190~2,970840~2,210~3,070

11.03.66

4.4~13.3/4.5~13.71,220~240,50

18~3016~30-10~43-15~24

18/16.5/14(636/583/494)8

38/36/342.5

34.6x10.2x17.7 (880x260x450)

35(77.2)

120/252

UB30

11,400~30,000~36,0003,340~8,791~10,549

13,110~34,500~41,4003,838~10,110~12,133

1,037~2,730~2,9801,064~2,800~4,500

11.03.61

5.9~13.0/6.5~19.71,220~240,50

18~3016~30-10~43-15~24

26.5/23/20(936/812/706)10

40/38/353.3

46.5x11.7x17.7(1180x298x450)

38(84)

95/191

• Cooling Only • Heating & Cooling DC INVERTER • Cooling Only • Heating & Cooling 3PHASE DC INVERTER

UU37W UU43W/UU49W/UU61W

Note :Due to our policy of innovation some specifications may be changed without notification.

Indoor Unit _

Outdoor Unit _

Model

Cooling Btu/hCapacity W(Min~Rating~Max) Heating Btu/h

WInput Cooling W(Min~Rating~Max) Heating WRunning Current Cooling/Heating AEER W/WCOP W/WPower Supply ø,V, HzSetting Temperature Cooling °CRange(Indoor) Heating °COperational Temperature Cooling °CRange(Outdoor) Heating °CPower Supply ø,V, HzAir Flow Rate H/M/L CMM(CFM)External Static Pressure mmAqNoise Level(SoundPress,1m) H/M/L dB(A)±3Dehumidification Rate I/hDimensions (WxHxD) inch(mm)Net Weight kg(lbs)Stuffing Quantity With S/Parts 20/40ft

UB36

20,400~34,000~37,4005,980~9,970~10,970

22,800~38,000~41,8006,680~11,140~12,250

1,840~3,070~3,3801,820~3,040~3,340

5.3/4.311.03.66

3,380~415,5018~3016~30-5~43

-15~241,220~240,50

32/29/26(1130/1024/918)10

42/39/364.0

46.5x11.7x17.7(1180x298x450)38(84)95/191

UB42

24,600~41,000~45,1007,210~12,020~13,220

29,400~49,000~53,9008,620~14,370~15,810

2,170~3,610~3,9702,180~3,640~4,000

6.1/6.111.43.95

3,380~415,5018~3016~30-5~43

-15~241,220~240,50

36/32/28(1271/1130/989)15

42/40/385.0

48.4x15.0x23.2(1230x380x590)60(132)57/120

UB48

28,800~48,000~52,8008,440~14,070~15,470

32,400~54,000~56,0009,500~15,820~16,4102,860~4,380~4,8202,850~4,300~4,730

7.0/6.411.03.68

3,380~415,5018~3016~30-5~43

-15~241,220~240,50

40/35/30(1413/1236/1059)15

44/42/406.0

48.4x15.0x23.2(1230x380x590)60(132)57/120

UB60

32,400~52,000~57,2009,500~15,240~16,760

34,800~58,000~61,00010,200~17,000~17,880

3,070~4,760~5,2403,100~4,700~5,200

8.0/7.110.93.62

3,380~415,5018~3016~30-5~43

-15~241,220~240,50

50/45/40(1766/1413/1236)15

46/44/426.5

48.4x15.0x23.2(1230x380x590)60(132)57/120

Model

Power Supply ø,V, HzCompressor(Constant) TypeRefrigerant Charge Charge g(oz)

TypeFan Discharge Side/TopNoise Level Sound Press, 1m dB(A)±3Pipe Connection Liquid inch(mm)

Gas inch(mm)Dimensions WxHxD inch(mm)Net Weight Outdoor kg(lbs)Power Supply Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2Max. Piping Length/Elevation mStuffing Quantity Without S/Parts 20/40ft

UU37W

3,380/415,50Twin Rotary2,500(88.2)

R410ASide Discharge

511/4 (6.35)

5/8 (15.88)34.3x41.7x12.6(870x1060x320)

805*2.5

4*0.7550/30

51/111

UU43W

3,380/415,50Twin Rotary4,000(141.1)

R410ASide Discharge

533/8(9.52)

3/4(19.05)35.4x45.8x14.5 (900x1165x370)

955*3.5

4*0.7550/3027/55

UU49W

3,380/415,50Twin Rotary4,000(141.1)

R410ASide Discharge

543/8 (9.52)

3/4 (19.05)35.4x45.8x14.5(900x1,165x370)

955*3.54*1.25 70/3027/55

UU61W

3,380/415,50Twin Rotary4,000(141.1)

R410ASide Discharge

553/8 (9.52)

3/4 (19.05)35.4x45.8x14.5(900x1,165x370)

955*3.5

4*1.2570/3027/55

Page 9: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

SINGLE PACKAGED TYPEEconomical and user-friendly model, designed for medium-sized houses and shops. Features include anumber of operation modes, auto restart and a washable anti-bacterial filter.

sin

gle

pa

ck

ag

ed

typ

e

16

17

LG AIR CONDITIONERS 2007

Single Packaged Type

Easy InstallationThe unit can be installed outdoors to save valuable indoorspace, or in locations where no ceiling space is available.Ground or roof installation options provide total flexibilityaccording to your requirements.

Easy Maintenance & ServiceThe all-in-one design, with all access panels located on oneside of the unit and color-coded wiring, greatly facilitatesmaintenance and service.

Additional functions available with ductsystemAll units are designed for reverse-cycle operation, whichmeans electric heating functions can be added byspecialized dealers. This model also allows complete controlover fresh air intake, ratio of air purification, as well asmonitoring and automatic zone control (additional featuresavailable from specialized dealers), through the powerful LGcontrol system.

LG’s Cooling Load Calculation ProgramSelecting an air conditioner with the right capacity is veryimportant. A unit that is too small or too big will not onlyaffect your comfort, but may also unnecessarily increaseyour initial purchasing cost and operational expenses. TheLG cooling load calculation program helps you choose theright system for your specific needs.

Free & Easy Air-CirculationA duct system allows you to freely control air-circulation.

Low Noise LevelAs the unit is located outdoors, indoor areas are keptcomfortably quiet.

➊ Roof Jack Installation➋ Roof Curb Installation❸ Slab-on-Ground Installation

Typical Installation

Page 10: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

• LK-C0608HA0

Features

• Compact & Lightweight Design • U-shape Air Flow • Safety Condenser Fin Guard

• Forklift Base rail • Easy access Panel • Time Delay Relay is Standard Component

• Low Pressure Switch is Standard Component • Durable Painted Steel Cabinet

• Scroll Compressor with internal high-pressure & Over-current Protector

• Factory Charged Refrigerant • Direct-drive multi-speed PSC Blower Motor

• Direct-drive PSC Condenser Fan Motor • Phase reversal Protection

Single Packaged Type

Glass-Cloth Laminated Polyurethane Foam InsulationHealthy Air

High Efficiency Heat ExchangersX-Louvered Fin (LG Patent) & Inner Grooved Tube addturbulance to air & refrigerant flow to give higher efficiency& cooling capacity.

Anti-Short Cycle Timer & Low Pressure SwitchTo Protect Refrigerant Cycle Defect

Compact & Lightweight Design

Supplemental Electric Heater(Optional)Allows for easy handling & installation

Forkable Base RailAllows for easy handling & installation

Large Centrifugal Fan For Low Noise and Adjustable Air Flow

Single Packaged Type _ Installation Reference

Sing

le Packaged

TypeLK-C0608HA0

59,900

-

380~415.50

20.4

6,400

56.7

8.0

1,102x830x725

140

30/64/96

Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions (WxHxD) mm

Net Weight Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

18 19

• Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification.

Page 11: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

• LK-0880AH

Features

• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation

• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level

• Easy Maintenance & Service • Additional Functions Available with Duct System

• Auto Restart

Single Packaged Type

20 21

• LK-C1208C00 / • LK-C1508C00

• AK-H1208C00

Features

• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation

• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level

• Easy Maintenance & Service • Additional Functions Available with Duct System

• Auto Restart • Hi & Low Pressure Switch is Standard Component

• Application Scroll Compressor • Phase Reversal & Missing Potection

Single Packaged Type

LK-0880AHModel

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions (WxHxD) mm

Net Weight Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

81,000

-

380~415.50/3

20.0

8,500

73.6

8.8

1,607x1,086x1,067

280

12/28/28

LK-C1508C00

149,000

-

380~415.50/3

38.3

14,500

141

8.6

2,160x1,230x1,390

400

4/8/16

LK-C1208C00Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions (WxHxD) mm

Net Weight Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

120,000

-

380~415.50/3

35.8

12,000

113

8.5

2,160x1,230x1,390

400

4/8/16

AK-H1208C00

120,000

112,000

380~415.50/3

38.2/38.2

14,400/11,600

110

8.0

2,160x1,230x1,390

450

4/8/16

Sing

le Packaged

Type

• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification. Note :Due to our policy of innovation some specifications may be changed without notification.

Page 12: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

KK-C3008C00

281,500

-

380~415.50/3

80.3

28,500

283

10.3

2,900x1,260x2,220

870

2/4/8

EK-H2408C00

240,000

250,000

380~415.50/3

77.4/77.4

26,500/27,800

226

9.2

2,900x1,260x2,220

900

2/4/8

KK-C2408C00

244,700

-

380~415.50/3

68.3

25,000

226

9.2

2,900x1,260x2,220

870

2/4/8

EK-C3608H00

360,000

-

380~415.50/3

85.0

33,000

311

10.3

2,688x1,720x2,220

1,070

2/4/4

• KK-C1808C00 / • KK-C2108C00

• EK-H1808C00

Features

• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation

• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level

• Easy Maintenance & Service • Additional Functions Available with Duct System

• Auto Restart • Hi & Low Pressure Switch is Standard Component

• Application Scroll Compressor • Phase Reversal & Missing Potection

Single Packaged Type

22 23

• KK-C2408C00 / • KK-C3008C00• KK-C3608H00

• EK-H2408C00

Features

• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation

• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level

• Easy Maintenance & Service • Additional Functions Available with Duct System

• Auto Restart

Single Packaged Type

Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions (WxHxD) mm

Net Weight Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

Sing

le Packaged

Type

KK-C2108C00

203,300

-

380~415.50/3

57

20,500

198

9.2

2,220x1,228x1,545

600

3/7/14

KK-C1808C00Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions (WxHxD) mm

Net Weight Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

182,300

-

380~415.50/3

52.9

18,000

165

9.2

2,220x1,228x1,545

550

3/7/14

EK-H1808C00

182,300

-

380~415.50/3

52.9

18,000

165

9.2

2,220x1,228x1,545

550

3/7/14

• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification. Note :Due to our policy of innovation some specifications may be changed without notification.

Page 13: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

DUCTED SPLIT TYPEEconomical and user-friendly model, designed for medium-sized houses and shops. Features include anumber of operation modes, auto restart and a washable anti-bacterial filter.

Du

cte

d S

plit T

yp

e

24

25

LED Wired Remote Controller

• TN-C0608SA0

Features

• 4way Convertibility-horizontal(Left & right), up-flow, down-flow

• Plastic drain Pan • High efficient Evaporator Coil • Galvanized Steel with painting

• Washable and Anti-fungus Filter • Multi-speed blower • Time delay PCB

• 220V primary & 24V secondary transformer • Defrost sensor

• Hi-Reliability Compressor • Compressor internal overload protection

• Internal pressure relief valve provides high pressure protection for compressor

• Outside pressure taps for refrigerant system check.

• Factory supplied charge of R-22

LK-C0608SA0

60,000

-

380~415.50/3

16.8

6,300

64.7

6.5

600x1,135x500

900x1,130x370

65/115

30/64/96

Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions Indoor mm(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

Model StructureAir Filter Guide

Blower Housing Assembly

‘A’ Type Indoor Coil

Plastic Drain Pan

LG AIR CONDITIONERS 2007

Ducted Split Type

• Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification.

Page 14: - O2 Airconditioning ·  181 BARBARA ROAD ELANDSFONTEIN ... - With a temperature sensor controlling every diffuser, ... • 3-Step Fan Speed selection

LN-0880CC

81,200

-

380~415.50/3

21.0

8,200

97

7.0

1,260x1,120x635

1,245x930x650

140/160

8/-/25

LN-C1208T00

112,100

-

380~415.50/3

32

11,500

130

7.5

1,260x1,120x635

712x828x687

150/92*2

8/-/25

LN-1380CC

137,500

-

380~415.50/3

37.0

13,400

150

8.0

1,260x1,120x635

1,245x930x650

160/160*2

6/-/16

LN-1580CC

166,500

-

380~415.50/3

42.0

16,200

190

8.0

1,460x1,653x818

1,245x930x650

190/160*2

4/-/9

LN-2080CC

224,000

-

380~415.50/3

54.0

23,000

250

8.0

1,460x1,653x818

1,245x930x650

210/169*2

4/-/9

• LN-0880CC / • LN-C1208T00• LN-1380CC / • LN-1580CC / • LN-2080CC

Features

• Compact Size • Micro-Processor Control Board • Quick and Easy Service Panels

• Anti-fungus, Hygienic and Easy-to-Clean filter • Convertible lnstallation

• Safety Condenser Fin Guard • Electric Heater (Optional)

• High/Low Static Driver Kit, Over Sized Motor(Optional)

• LCD Wired Remote Control

Ducted Split Type

Ducted Split Type _ Installation Reference

Du

cted Sp

lit Type

Model

Capacity

Cooling (Gross) Btu/hr

Heating Btu/hr

Electrical Data

Voltage, Frequency/Phase V,Hz/ø

M.C.A(with standard motor) Cooling / Heating Amps

Power Input Cooling / Heating Watt

Performance

Air Circulation Indoor m3/min

Sound Rating bell

Installation & Stuffing

Net Dimensions Indoor mm(WxHxD) Outdoor mm

Net Weight Indoor/Outdoor Kg

Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi

Specification

26 27

Model StructureBlower Housing Ass’y

Heat Exchanger Coil

Drain fan

Controller with MicroprocessorMechanical Thermostat isConnectable Without AnyInterface To Control Board

- Self diagnosis Function- Humidity Control- Fire Alarm lnter lock (Power off)- Auto Restart Function- E/Heater 2-Stage Control (36KW)- Anti-Short Cycle Timer (3min . Delay)- Time Delay Relay(each 10 Sec.)- in motor→Out motor→Comp- Anti-Freeze Control-Eva 0°C±2°C : off- Test key

LCD Wired Remote Controller

• 24-Hour ON/ OFF Timer in 1-hour intervals• TEST RUN Mode• Self-Diagnosis function• Operation Indication• Room Temperature Display• Only 20mm thick

Optional -Wireless Remote controller

*Optional

- Central Control- Group Control- Zone Controller- Anti Corrosion Gold Fin- Two Thermistor Control - High/Low Static Driver Kit,Over Size Motor- E/Heater

• Cooling Only • Heating & Cooling

Note :Due to our policy of innovation some specifications may be changed without notification.