- o2 airconditioning · 181 barbara road elandsfontein ... - with a temperature sensor controlling...
TRANSCRIPT
For co
ntin
ual p
rod
uct d
evelop
men
t, LG reserves th
e righ
t to ch
ang
e specificatio
ns w
itho
ut n
otice.
© LG
Electron
ics Inc. Prin
ted in
Ko
rea 2006
S.A-CA071
LG Air Conditioning 2007We always pursue highly advanced technologies to improve the quality of your life.
Enjoy a clean, quiet & comfortable life with LG Air Conditioners.
ww
w.l
ge
.co
.za
181 BARBARA ROAD ELANDSFONTEINP.O.BOX 473. ISANDO 1600, SOUTH AFRICAPhone : 27 11 571 6700http://www.lge.co.za
LG Electronics, The World’s Best Seller,Seven Years in a Row
World-renowned cooling appliance and airconditioner magazine JARN has selected LG as theNo. 1 Seller for SEVEN consecutive years. LG believesthat its achievement is the result of giving theconsumers nothing but the best. LG promises tocontinue to innovate itself and move forward.
HIDE-AWAY TYPE 06
CONTENTS
SINGLE PACKAGED TYPE 16
DUCTED SPLIT TYPE 24
Models _ Line up The World’s Number 1 Choice in Air Conditioners!
Single Packaged Type Ducted Split Type
Btu/h
3~6tons 7.5~30tons 3~5tons 7.5~10tons 12.5~20tons
18,000 24,000 30,000 36,000 42,000 48,000 60,000 72,000 100,000 120,000
Hide-Away Type
Single Split Mid-Wall Type
Window Type
Ceiling Cassette Type
Floor Standing Type
Underceiling Type
18,0007,000Btu/h 9,000 12,000 18,000 22,000 24,000 26,000 30,000 36,000 48,000 60,000 72,000 80,000
HIDE-AWAY TYPEHidden in the ceiling, this model is designed for buildings that require floor level air conditioning for manyindividual rooms or large areas, like restaurants, concert halls and hotels. Installation is not restricted bylighting fixtures or the building layout, and interior renovation is made easy by installing ventilation diffusers.
Hid
e-A
wa
y T
yp
e
06
07
LG AIR CONDITIONERS 2007
*E.S.P: External Static PressureThe air volume and sound level is kept constant as designedregardless of changes in E.S.P.(External Static Pressure)E.S.P. technology - Optimizes Duct Installation- Keeps Capacity & Sound Levels within desired ranges- Reduces the number of modelsPhase control motor technology reduces installation costs.The desired air flow is obtained by adjusting the phasemotor during installation of the product, giving you moreflexibility when setting up your duct system. The E.S.P canbe adjusted linearly from 0 to 10mmAq.
PLASMA Air Purifying System (Optional)The integrated PLASMA Air Purifying System removesmicroscopic contaminants and dust, eliminates offensiveodors and prevents allergic reactions. It can also be used asan air-purifying unit only, without running the airconditioner.
Hide-Away Type
Evaluated by CSIRO Australia (DBCE Doc 98/204)
Tested by Korean Food Research Institute and Japanese Environmental Centre and
Yonsei Univ. College of Medicine. (Allergy Research Lab.)
Respirable particles from 5 cigarettes in a sealedroom removed by the LG Plasma Air PurifyingSystem.
LG's Plasma Air Purifying unit effectively removeshigh concentrations of tobacco odors (Confirmedin sensory tests carried out in Korea and Japan.)
In clinical tests, the LG Plasma Air Purifying Systemreached a satisfaction level of 82% .
> Dust Reduction
> Deodorization
> Anti-Allergy
Hid
e-A
wa
y T
yp
e
08
09
LG AIR CONDITIONERS 2007
Hide-Away Type
Long Distance Piping High ElevationLG Air Conditioners (Cassette and Duct-type models) can beinstalled at long distances (max 50m) and high heightdifferences (30m) from the outdoor unit.
Plz refer to the picture below.
Zone Controller (Optional)1) Basic Operation
- With a temperature sensor controlling every diffuser,the temperature for each zone can be monitored andadjusted automatically.
2) Control Features- If every damper is closed, the compressor and outer fan
are turned off, to protect the compressor.
Central Controller (Option)1) Basic Operation
-Linking several units, one Central Control Unit canmanage and turn off several units individually or as agroup.
2) Control Features - Each indoor unit is connected to a Central Control Unit
via a data communication cable and can be operated orturned off individually or together with a group of unitswith the central controller.
- The Central Control Unit can manage up to 8 * 16 indoorunits.
Zero standby power consumption- Eliminates waste of electricity in standby mode.- Electricity is wasted when an appliance is connected to an
outlet, even though the appliance is turned off. - Development of a super power-saving SMPS (Swiching
Mode Power Supply)- Minimal standby power consumption (90% reduction of
standby power).- No need to pull the main power plug when the appliance
is not in use.
Auto ChangeoverNeed not control on each times at big diurnal range areas.
Two Thermistor ControlThe dual thermistor control regulates the differencebetween the indoor temperature and the temperature ofthe conditioned air by monitoring both temperatures, toensure a uniform room temperature. The sensor readingsare adjusted for optimum room temperature.
Heating
Dehumidifying
Cooling
Micro Processor
Analyze 3 Temperature
Measure Periodically
Target Temperature
Outdoor Temperature
Indoor Temperature
High Head Drain Pump (Optional)The High Head Drain Pump pumps water up to 700mm highfor smooth drainage.
Pipe fixture
FlexibleDrain Hose
Drain pump
Wall
Drain pipe
700mm
50m 30m
Timer-controlled OperationIf desired, you can set operation times for up to one week inadvance.
LCD Wired Remote Controller
• 24-Hour ON/ OFF Timer with 1 hour intervals
• TEST RUN Mode
• Self-Diagnosis feature
• 3-Step Fan Speed selection
• Operation Indicator
• Room Temperature Display
• Only 20mm thick
OptionWireless Remote controller
Zone A
Zone C
Zone D
Zone B
On Off
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
1 2 16
Controller#1
Controller#2
On Off
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16 Controller#8
On Off
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
1 2 16
Gold Fin™ Anti CorrosionLG’s Outdoor Heat Exchanger is coated with a gold-coloredanti-corrosive epoxy treatment on the aluminum coil, toprevent corrosion. This maintainsexcellent heat transferproperties of the coil for an extended time, whereas non-Gold FinTM coils progressively lose efficiency due to surfacecorrosion. Gold FinTM fin is perfect for areas with highpollution or locations exposed to saltwater spray from thesea.
Gold Coated Aluminum Uncoated Aluminum
LG Gold Fin™Corrosion Free
ConventionalStarting to corrode
After 15 Days After 15 Days
Salt Spray Test for 15 Days
Group Control1) Basic Operation
- Linking several units, one Group Control Unit canmanage a number of indoor units.
2) Control Features- Through a data cable connected to each indoor unit, a
group of units can be managed from the groupcontroller.
- The Group Control function is enabled by cutting anoptional jump wire in the wired remote control, whichprevents data collision.
- One Group Control Unit can control up to 16 indoorunits.
2 16........
........
Hid
e Aw
ay Type
• LB-H1208VA0
Features
• Weekly Program • Auto Changeover • Two Thermistor Control
• Group Control • 24-Hour ON/OFF • Child Lock Function
• Auto Restart • Anti Corrosion Gold FinTM(Outdoor)
• Central controller(Optional)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
Less NoiseThe product has considerably less noise levelinside resulting from changing to the direct-drive method from the pre-established pulleymethod of the blower and the motor.
Convenience in Installation(convertible flow)You can adjust the air flow either vertically orhorizontally depending on the characteristicsof the space where it's installed.
• High efficiency, less noise, lowenergy intake, fresh air intake
• An invertible fan motor has beeninstalled.
• The air volume can be controlledby the wired remotecontroller.(0~20mmAq)
Conventional_Pulley
→ →New_Direct Drive
75dB LB-H1208VA0Model
Capacity
Cooling Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
Power Input. Cooling / Heating Watt
Running Current Cooling / Heating A
Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor m3/min
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity With S/Parts 20/40ft
Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
120,000)
132,000
380~415,50/3
15,000 / 13,000
24/21
8.0(2.34)
10.8(3.15)
105
10
53
65
0~20
5*8.5
6*1.25
1,700x712x837
1,280x1,520x730
130/300
-
6/14
15.88/28
10 11
• LB-H1860BS1 / • LB-H2460BS1• LB-H306GSS0 / • LB-H366GSS0
Features
• Long Distance, High Elevation • Weekly Program • Standby Power Zero
• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart
• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)
• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)
• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
LB-H306GSS0
30,000
30,000
220~240.50/1
3,150/2,600
14/12
9.5
3.38
26.5/23/20
3.00
40/38/36
56
10
3*3.5
5*0.75
1,180x298x450
870x655x320
38/64
32/70
36/74
6.35/15.88
LB-H366GSS0
36,000
36,000
220~240.50/1
4,000/3,300
18.5/15.5
9.0
3.2
32/29/26.5
3.5
42/40/38
56
10
3*5.5
5*0.75
1,180x298x450
870x808x320
38/66
32/70
36/74
6.35/15.88
LB-H1860BS1
18,000
18,000
220~240.50/1
2,000/1,880
10.0/9.5
9.0
2.8
16.5/14.5/13
2.00
36/34/32
55
8
3*2.5
6*0.75
880x260x450
870x655x320
34/57
42/94
48/101
6.35/15.88
LB-H2460BS1
24,000
24,000
220~240.50/1
2,650/2,400
12.5/11.3
9.1
2.93
18/16.5/14
2.50
37/35/33
55
8
3*2.5
6*0.75
880x260x450
870x655x320
35/60
42/94
48/101
6.35/15.88
Model
Capacity
Cooling Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
Power Input. Cooling / Heating Watt
Running Current Cooling / Heating A
Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) m3/min
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity With S/Parts 20/40ft
Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification.Note :Due to our policy ofinnovation some specificationsmay be changed withoutnotification.
Hid
e-Aw
ay Type
• LB-M7280BS / • LB-M1080BS
Features
• Long Distance, High Elevation • Weekly Program • Standby Power Zero
• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart
• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)
• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)
• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
• LB-H368GSS0 / • LB-H428GSS0• LB-H488RSS0 / • LB-H608RSS0
Features
• Long Distance, High Elevation • Weekly Program • Standby Power Zero
• Two Thermistor Control • Group Control • Child Lock Function • Auto Restart
• EZ Tuning • Zone Control(Optional) • High Head Drain Pump(Optional)
• Wireless Remote Controller(Optional) • Gold Fin Anti Corrosion(Optional)
• PLASMA Air Purifying system(Optional) • Central ControllerI(Optional)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
12 13
LB-H368GSS0
36,000
36,000
380~415.50/3
4,000/3,300
7.2/6.3
9.0
3.2
32/29/26.5
3.50
42/40/38
58
10
4*2.5
5*0.75
1,180x298x450
870x808x320
38/66
32/70
36/74
6.35/15.88
LB-H428GSS0
42,000
42,000
380~415.50/3
4,350
7.3
9.6
10.24
32/29/26.5
5.00
42/40/38
60
10
5*2.5
5*0.75
1,180x298x450
900x1,130x370
38/93
27/55
27/55
9.52/19.05
LB-H488RSS0
48,000
48,000
380~415.50/3
5,500/4,500
9.0/8.0
8.7
3.13
45/40/35
6.00
49/47/45
62
10
4x3.5
5x1.25
1,230 x 380 x 590
900 x 1,130 x 370
53/93
22/51
24/51
9.52/19.05
LB-H608RSS0
57,000
60,000
380~415.50/3
6,150/4,900
10.5/8.5
9.3
3.6
50/45/40
6.5
49/47/45
62
10(Max15)
4x3.5
5x1.25
1,230 x 380 x 590
900 x 1,130 x 370
53/93
22/51
24/51
9.52/19.05
Model
Capacity
Cooling Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
Power Input. Cooling / Heating Watt
Running Current Cooling / Heating A
Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) m3/min
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity With S/Parts 20/40ft
Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
SpecificationSpecification
LB-M7280BSModel
Capacity
Cooling Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
Power Input. Cooling / Heating Watt
Running Current Cooling / Heating A
Performance
EER Cooling Btu/hr.W
COP Heating W/W
Moisture Removal l /hr
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kgs
Service Valve Liquid/Gas ø(mm)
72,000
72,000
380~415.50/3
7,000/6,800
13/13
10.3
3.1
5.86
1,416 x 400 x 575
1,245 x 930 x 650
58/185
12.7/25.4
LB-M1080BS
100,000
104,000
380~415.50/3
10,500/8,700
17.0/14.7
9.5
3.5
6.30
1,696 x 450 x 658
1,245 x 930 x 650
88/195
15.88/28.6
• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
Hid
e-Aw
ay Type
• UB36 / • UB42 / • UB48 / • UB60
Features
• Weekly Program • Auto Changeover • Two Thermistor Control
• Group Control • 24-Hour ON/OFF • Child Lock Function • Auto Restart
• Hot Start (Heat pump Model) • Anti Corrosion Gold Fin(Outdoor)
• Zone Control(Accessory) • Central controller(Accessory)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
• UB18 / • UB24 / • UB30
Features
• Weekly Program • Auto Changeover • Two Thermistor Control
• Group Control • 24-Hour ON/OFF • Child Lock Function • Auto Restart
• Hot Start (Heat pump Model) • Anti Corrosion Gold Fin(Outdoor)
• Zone Control(Accessory) • Central controller(Accessory)
Hide-Away Type
24-Hour OFFSetting Timer
24Child Lock Group
Controller
14 15UU18W UU24W UU30W
Model
Compressor(Inverter) TypeCompressor(Constant) TypeRefrigerant Charge Charge g(oz)
TypeFan Discharge Side/TopNoise Level Sound Press, 1m dB(A)±3Pipe Connection Liquid inch(mm)
Gas inch(mm)
Dimensions WxHxD inch(mm)
Net Weight Outdoor kg(lbs)Power Supply Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2Max. Piping Length/Elevation mPower Supply ø,V, HzStuffing Quantity Without S/Parts 20/40ft
UU18W
e-Scroll-
1500(52.91)R410A
Side Discharge51/45
1/4 (6.35)1/2 (12.7)
34.3*25.8*12.6 (870*655*320)
52(115)3*2.5
4*0.7540/30
1,220-240,50
81/171
UU24W
e-ScrollRotary
1750(61.72)R410A
Side Discharge52/46
1/4 (6.35)1/2 (12.7)
34.3*31.5*12.6 (870*800*320)
69(152)3*2.5
4*0.7550/30
1,220-240,50
54/114
UU30W
e-ScrollRotary
2100(74.07)R410A
Side Discharge50/46
1/4 (6.35)5/8 (15.88)
34.3*41.7*12.6 (870*1060*320)
80(176)3*2.5
4*0.7550/30
1,220-240,50
51/111
Indoor Unit _
Note :Due to our policy of innovation some specifications may be changed without notification.
Outdoor Unit _
Model
Cooling Btu/hCapacity W(Min~Rating~Max) Heating Btu/h
WInput Cooling W(Min~Rating~Max) Heating WE.E.R W/WC.O.P W/WRunning Current Cooling/Heating APower Supply ø,V, HzSetting Temperature Cooling °CRange(Indoor) Heating °COperational Temperature Cooling °CRange(Outdoor) Heating °CAir Flow Rate H/M/L CMM(CFM)External Static Pressure mmAqNoise Level(SoundPress,1m) H/M/L dB(A)±3Dehumidification Rate I/h
Dimensions (WxHxD) inch(mm)
Net Weight kg(lbs)Stuffing Quantity Without S/Parts 20/40ft
UB18
6,840~18,000~21,6002,006~5,275~6,329
7,714~20,300~24,8402,261~5,949~7,280623~1,640~2,370627~1,650~2,370
11.03.61
2.3~7.5/3.5~10.61,220~240,50
18~3016~30-10~43-15~24
16.5/14.5/13(583/512/459)8
36/34/322.0
34.6x10.2x17.7(880x260x450)
35(77.2)
120/252
UB24
9,120~24,000~28,8002,671~7,034~8,440
10,488~27,600~32,0003,074~8,089~9,376832~2,190~2,970840~2,210~3,070
11.03.66
4.4~13.3/4.5~13.71,220~240,50
18~3016~30-10~43-15~24
18/16.5/14(636/583/494)8
38/36/342.5
34.6x10.2x17.7 (880x260x450)
35(77.2)
120/252
UB30
11,400~30,000~36,0003,340~8,791~10,549
13,110~34,500~41,4003,838~10,110~12,133
1,037~2,730~2,9801,064~2,800~4,500
11.03.61
5.9~13.0/6.5~19.71,220~240,50
18~3016~30-10~43-15~24
26.5/23/20(936/812/706)10
40/38/353.3
46.5x11.7x17.7(1180x298x450)
38(84)
95/191
• Cooling Only • Heating & Cooling DC INVERTER • Cooling Only • Heating & Cooling 3PHASE DC INVERTER
UU37W UU43W/UU49W/UU61W
Note :Due to our policy of innovation some specifications may be changed without notification.
Indoor Unit _
Outdoor Unit _
Model
Cooling Btu/hCapacity W(Min~Rating~Max) Heating Btu/h
WInput Cooling W(Min~Rating~Max) Heating WRunning Current Cooling/Heating AEER W/WCOP W/WPower Supply ø,V, HzSetting Temperature Cooling °CRange(Indoor) Heating °COperational Temperature Cooling °CRange(Outdoor) Heating °CPower Supply ø,V, HzAir Flow Rate H/M/L CMM(CFM)External Static Pressure mmAqNoise Level(SoundPress,1m) H/M/L dB(A)±3Dehumidification Rate I/hDimensions (WxHxD) inch(mm)Net Weight kg(lbs)Stuffing Quantity With S/Parts 20/40ft
UB36
20,400~34,000~37,4005,980~9,970~10,970
22,800~38,000~41,8006,680~11,140~12,250
1,840~3,070~3,3801,820~3,040~3,340
5.3/4.311.03.66
3,380~415,5018~3016~30-5~43
-15~241,220~240,50
32/29/26(1130/1024/918)10
42/39/364.0
46.5x11.7x17.7(1180x298x450)38(84)95/191
UB42
24,600~41,000~45,1007,210~12,020~13,220
29,400~49,000~53,9008,620~14,370~15,810
2,170~3,610~3,9702,180~3,640~4,000
6.1/6.111.43.95
3,380~415,5018~3016~30-5~43
-15~241,220~240,50
36/32/28(1271/1130/989)15
42/40/385.0
48.4x15.0x23.2(1230x380x590)60(132)57/120
UB48
28,800~48,000~52,8008,440~14,070~15,470
32,400~54,000~56,0009,500~15,820~16,4102,860~4,380~4,8202,850~4,300~4,730
7.0/6.411.03.68
3,380~415,5018~3016~30-5~43
-15~241,220~240,50
40/35/30(1413/1236/1059)15
44/42/406.0
48.4x15.0x23.2(1230x380x590)60(132)57/120
UB60
32,400~52,000~57,2009,500~15,240~16,760
34,800~58,000~61,00010,200~17,000~17,880
3,070~4,760~5,2403,100~4,700~5,200
8.0/7.110.93.62
3,380~415,5018~3016~30-5~43
-15~241,220~240,50
50/45/40(1766/1413/1236)15
46/44/426.5
48.4x15.0x23.2(1230x380x590)60(132)57/120
Model
Power Supply ø,V, HzCompressor(Constant) TypeRefrigerant Charge Charge g(oz)
TypeFan Discharge Side/TopNoise Level Sound Press, 1m dB(A)±3Pipe Connection Liquid inch(mm)
Gas inch(mm)Dimensions WxHxD inch(mm)Net Weight Outdoor kg(lbs)Power Supply Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2Max. Piping Length/Elevation mStuffing Quantity Without S/Parts 20/40ft
UU37W
3,380/415,50Twin Rotary2,500(88.2)
R410ASide Discharge
511/4 (6.35)
5/8 (15.88)34.3x41.7x12.6(870x1060x320)
805*2.5
4*0.7550/30
51/111
UU43W
3,380/415,50Twin Rotary4,000(141.1)
R410ASide Discharge
533/8(9.52)
3/4(19.05)35.4x45.8x14.5 (900x1165x370)
955*3.5
4*0.7550/3027/55
UU49W
3,380/415,50Twin Rotary4,000(141.1)
R410ASide Discharge
543/8 (9.52)
3/4 (19.05)35.4x45.8x14.5(900x1,165x370)
955*3.54*1.25 70/3027/55
UU61W
3,380/415,50Twin Rotary4,000(141.1)
R410ASide Discharge
553/8 (9.52)
3/4 (19.05)35.4x45.8x14.5(900x1,165x370)
955*3.5
4*1.2570/3027/55
SINGLE PACKAGED TYPEEconomical and user-friendly model, designed for medium-sized houses and shops. Features include anumber of operation modes, auto restart and a washable anti-bacterial filter.
sin
gle
pa
ck
ag
ed
typ
e
16
17
LG AIR CONDITIONERS 2007
Single Packaged Type
Easy InstallationThe unit can be installed outdoors to save valuable indoorspace, or in locations where no ceiling space is available.Ground or roof installation options provide total flexibilityaccording to your requirements.
Easy Maintenance & ServiceThe all-in-one design, with all access panels located on oneside of the unit and color-coded wiring, greatly facilitatesmaintenance and service.
Additional functions available with ductsystemAll units are designed for reverse-cycle operation, whichmeans electric heating functions can be added byspecialized dealers. This model also allows complete controlover fresh air intake, ratio of air purification, as well asmonitoring and automatic zone control (additional featuresavailable from specialized dealers), through the powerful LGcontrol system.
LG’s Cooling Load Calculation ProgramSelecting an air conditioner with the right capacity is veryimportant. A unit that is too small or too big will not onlyaffect your comfort, but may also unnecessarily increaseyour initial purchasing cost and operational expenses. TheLG cooling load calculation program helps you choose theright system for your specific needs.
Free & Easy Air-CirculationA duct system allows you to freely control air-circulation.
Low Noise LevelAs the unit is located outdoors, indoor areas are keptcomfortably quiet.
➊ Roof Jack Installation➋ Roof Curb Installation❸ Slab-on-Ground Installation
Typical Installation
❸
➊
➋
• LK-C0608HA0
Features
• Compact & Lightweight Design • U-shape Air Flow • Safety Condenser Fin Guard
• Forklift Base rail • Easy access Panel • Time Delay Relay is Standard Component
• Low Pressure Switch is Standard Component • Durable Painted Steel Cabinet
• Scroll Compressor with internal high-pressure & Over-current Protector
• Factory Charged Refrigerant • Direct-drive multi-speed PSC Blower Motor
• Direct-drive PSC Condenser Fan Motor • Phase reversal Protection
Single Packaged Type
Glass-Cloth Laminated Polyurethane Foam InsulationHealthy Air
High Efficiency Heat ExchangersX-Louvered Fin (LG Patent) & Inner Grooved Tube addturbulance to air & refrigerant flow to give higher efficiency& cooling capacity.
Anti-Short Cycle Timer & Low Pressure SwitchTo Protect Refrigerant Cycle Defect
Compact & Lightweight Design
Supplemental Electric Heater(Optional)Allows for easy handling & installation
Forkable Base RailAllows for easy handling & installation
Large Centrifugal Fan For Low Noise and Adjustable Air Flow
Single Packaged Type _ Installation Reference
Sing
le Packaged
TypeLK-C0608HA0
59,900
-
380~415.50
20.4
6,400
56.7
8.0
1,102x830x725
140
30/64/96
Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
18 19
• Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification.
• LK-0880AH
Features
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level
• Easy Maintenance & Service • Additional Functions Available with Duct System
• Auto Restart
Single Packaged Type
20 21
• LK-C1208C00 / • LK-C1508C00
• AK-H1208C00
Features
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level
• Easy Maintenance & Service • Additional Functions Available with Duct System
• Auto Restart • Hi & Low Pressure Switch is Standard Component
• Application Scroll Compressor • Phase Reversal & Missing Potection
Single Packaged Type
LK-0880AHModel
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
81,000
-
380~415.50/3
20.0
8,500
73.6
8.8
1,607x1,086x1,067
280
12/28/28
LK-C1508C00
149,000
-
380~415.50/3
38.3
14,500
141
8.6
2,160x1,230x1,390
400
4/8/16
LK-C1208C00Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
120,000
-
380~415.50/3
35.8
12,000
113
8.5
2,160x1,230x1,390
400
4/8/16
AK-H1208C00
120,000
112,000
380~415.50/3
38.2/38.2
14,400/11,600
110
8.0
2,160x1,230x1,390
450
4/8/16
Sing
le Packaged
Type
• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification. Note :Due to our policy of innovation some specifications may be changed without notification.
KK-C3008C00
281,500
-
380~415.50/3
80.3
28,500
283
10.3
2,900x1,260x2,220
870
2/4/8
EK-H2408C00
240,000
250,000
380~415.50/3
77.4/77.4
26,500/27,800
226
9.2
2,900x1,260x2,220
900
2/4/8
KK-C2408C00
244,700
-
380~415.50/3
68.3
25,000
226
9.2
2,900x1,260x2,220
870
2/4/8
EK-C3608H00
360,000
-
380~415.50/3
85.0
33,000
311
10.3
2,688x1,720x2,220
1,070
2/4/4
• KK-C1808C00 / • KK-C2108C00
• EK-H1808C00
Features
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level
• Easy Maintenance & Service • Additional Functions Available with Duct System
• Auto Restart • Hi & Low Pressure Switch is Standard Component
• Application Scroll Compressor • Phase Reversal & Missing Potection
Single Packaged Type
22 23
• KK-C2408C00 / • KK-C3008C00• KK-C3608H00
• EK-H2408C00
Features
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Free Easy Air-Circulation • Oversized moter (Optional) • Low Noise Level
• Easy Maintenance & Service • Additional Functions Available with Duct System
• Auto Restart
Single Packaged Type
Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
Sing
le Packaged
Type
KK-C2108C00
203,300
-
380~415.50/3
57
20,500
198
9.2
2,220x1,228x1,545
600
3/7/14
KK-C1808C00Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
182,300
-
380~415.50/3
52.9
18,000
165
9.2
2,220x1,228x1,545
550
3/7/14
EK-H1808C00
182,300
-
380~415.50/3
52.9
18,000
165
9.2
2,220x1,228x1,545
550
3/7/14
• Cooling Only • Heating & Cooling • Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification. Note :Due to our policy of innovation some specifications may be changed without notification.
DUCTED SPLIT TYPEEconomical and user-friendly model, designed for medium-sized houses and shops. Features include anumber of operation modes, auto restart and a washable anti-bacterial filter.
Du
cte
d S
plit T
yp
e
24
25
LED Wired Remote Controller
• TN-C0608SA0
Features
• 4way Convertibility-horizontal(Left & right), up-flow, down-flow
• Plastic drain Pan • High efficient Evaporator Coil • Galvanized Steel with painting
• Washable and Anti-fungus Filter • Multi-speed blower • Time delay PCB
• 220V primary & 24V secondary transformer • Defrost sensor
• Hi-Reliability Compressor • Compressor internal overload protection
• Internal pressure relief valve provides high pressure protection for compressor
• Outside pressure taps for refrigerant system check.
• Factory supplied charge of R-22
LK-C0608SA0
60,000
-
380~415.50/3
16.8
6,300
64.7
6.5
600x1,135x500
900x1,130x370
65/115
30/64/96
Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions Indoor mm(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
Model StructureAir Filter Guide
Blower Housing Assembly
‘A’ Type Indoor Coil
Plastic Drain Pan
LG AIR CONDITIONERS 2007
Ducted Split Type
• Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification.
LN-0880CC
81,200
-
380~415.50/3
21.0
8,200
97
7.0
1,260x1,120x635
1,245x930x650
140/160
8/-/25
LN-C1208T00
112,100
-
380~415.50/3
32
11,500
130
7.5
1,260x1,120x635
712x828x687
150/92*2
8/-/25
LN-1380CC
137,500
-
380~415.50/3
37.0
13,400
150
8.0
1,260x1,120x635
1,245x930x650
160/160*2
6/-/16
LN-1580CC
166,500
-
380~415.50/3
42.0
16,200
190
8.0
1,460x1,653x818
1,245x930x650
190/160*2
4/-/9
LN-2080CC
224,000
-
380~415.50/3
54.0
23,000
250
8.0
1,460x1,653x818
1,245x930x650
210/169*2
4/-/9
• LN-0880CC / • LN-C1208T00• LN-1380CC / • LN-1580CC / • LN-2080CC
Features
• Compact Size • Micro-Processor Control Board • Quick and Easy Service Panels
• Anti-fungus, Hygienic and Easy-to-Clean filter • Convertible lnstallation
• Safety Condenser Fin Guard • Electric Heater (Optional)
• High/Low Static Driver Kit, Over Sized Motor(Optional)
• LCD Wired Remote Control
Ducted Split Type
Ducted Split Type _ Installation Reference
Du
cted Sp
lit Type
Model
Capacity
Cooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Voltage, Frequency/Phase V,Hz/ø
M.C.A(with standard motor) Cooling / Heating Amps
Power Input Cooling / Heating Watt
Performance
Air Circulation Indoor m3/min
Sound Rating bell
Installation & Stuffing
Net Dimensions Indoor mm(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20ft/40ft/40ftHi
Specification
26 27
Model StructureBlower Housing Ass’y
Heat Exchanger Coil
Drain fan
Controller with MicroprocessorMechanical Thermostat isConnectable Without AnyInterface To Control Board
- Self diagnosis Function- Humidity Control- Fire Alarm lnter lock (Power off)- Auto Restart Function- E/Heater 2-Stage Control (36KW)- Anti-Short Cycle Timer (3min . Delay)- Time Delay Relay(each 10 Sec.)- in motor→Out motor→Comp- Anti-Freeze Control-Eva 0°C±2°C : off- Test key
LCD Wired Remote Controller
• 24-Hour ON/ OFF Timer in 1-hour intervals• TEST RUN Mode• Self-Diagnosis function• Operation Indication• Room Temperature Display• Only 20mm thick
Optional -Wireless Remote controller
*Optional
- Central Control- Group Control- Zone Controller- Anti Corrosion Gold Fin- Two Thermistor Control - High/Low Static Driver Kit,Over Size Motor- E/Heater
• Cooling Only • Heating & Cooling
Note :Due to our policy of innovation some specifications may be changed without notification.