LC-1 ASSEMBLY INSTRUCTIONS.PER COVER
CONTROLLER
LOWER COVER
SCREWS
I\4OUNTING BRACKET
RELEASE LEVER
MANUAL OVERRIDE
ACTUATORO-RING
Make suredo not loose it
FLOWDIRECTION
PLASTIC VALVE
VALVE ASSEMBLYScrew the agualQl clockwise until it reaches the bottom of the cavity.
NOTE: a small O-RING (Parker Nq 2-006) must first be inserted as shown
DO NOT USE TOOLS TO TIGHTEN THE ACTUATOR.
DO NOT OVER TIGHTEN IT.
Connect the valve assembly to the water line.
Make sure that flow arrow on the valve shows the right llow
direction.Once connected to the water system, turn on the water to
detect eventual leakage ( OPEN and CLOSE the va ve with
the actuaior manual override ). Return the overrlde to AUTO.
Please note: you have to turn the red arrow all the way 1804
to the desired position.
CONTROLLER ASSEMBLY( for valve mounting only )Connect the mount ng bracket to the back ol thecontroller !s ng the 4 screws.
FINAL ASSEMBLYPlace the controller assembly over the actuator untilit snaps into position. lvlake sure the actuator wire isfree and clear oui of the bracket.
WIRE CONNECTIONDo not remove the rubber plug on the bottom of thecontroller. Use the hardened tip oi the wire to punch
a hole in it and thread the w res through. Usrng a
coin, remove the lower cover and connect the wiresto the terrninal blocks as shown below. CONNECTTHE BLACK & WHITE wire to "+' (Plus) and theBLACK wire to "-' (N/inus).
BATTERY CONNECTION(Battery not supplied)connect a 9v ALKALINE battery and place it into itscompartment. The display will flash 3 times showingall the segments followed by the "OFF" command ,
resetting the actuators to the "CLOSE" position.
Close the lower cover.
WALL MOUNTl\4ount the unlt on a wall by sliding the 2slots found on the back of the unit over2 screw heads, place 90mm apart.
WALL MOUNT
IMPORTANT INFORMATION
. The button leads you through the programming steps.
. lf you are losl or wish to go to
continuously for a few seconds until display shows
o'"" l$il asaln to advance to
running stage.
which is the automatic
e,..r. [Eil to start prosrammins asain
. Auto return. ll within 3 minutes, you do not touch any button, the controller
will automatically go to
. lf you press continuously, the digits will advance quickly.
. Setting reset : il you 0,... ffil *o m simultaneously,
the digits will reset back to "0".
. Watering days can be programmed in two ways:
1. You can identify the day ol the week lor watering (SUN, MON,
TUE etc...)2. You can choose the number of days'interval between waterings(a 2 day cycle means that the watering will take place every two
days.)
CONTROL PANEL
SUN MON TUE WED/THU FRY SAT
"# 12:00
CONTROL BUTTONS
1 . NEXT STEP buttonUsed to advance program steps.
2. DAY /. STN buttonUsed to advance DAYS or STATIONS.
3. HRS / ON buttonUsed to change HOURS or "ON"function.
4. MIN / OFFUsed to advance I/INUTES or "OFF"function.
DISPLAY INDICATORS
5, DAYS OF THE WEEK.
6. PROGRAM STEPS INDICATOR.
7. BAfi: indicates low battery.
8. STATIONS ne indicators.
9. OFF: The controller is in RAIN-OFF mode.
10. DAY CYCLE : indicates irrigationprogramming by interval of days betweenwaterings.
PROGRAM STEPS
@
E@0:30
E@
DAY CYCLE
Eil7:oo@@
to advance to the nexl program step EEEIEEEE
Press ffi to set the hours ol the l rst starting time for lhls stalion
Press ffi to set the minules.
Press i@ ro advance 10 lne nexl prog'a- step and program
addit onal walering slans rol tlis slat'o1 on the sa-e day
Press [S to advance to the next program .t.p EEIEII
Press fPl to ooer tre va.ve o'tqe'lasl-i19 slatioltagu,
Press ffi to close the valve
Press [ffl to eo to AUro-RUN / oFF
to set loday's day
to set the present hour
to set the minules
Press 'X to set the hours of lhe watering duration lol this station
Press - to set the minuies
*=
ii you do not want to irrigate on the flashing day
to irrigate on the flash ng day
Press [ffi to stav w thlOR lpt.r.the weekly I I
To resel back to 0, prtt. ffi a
ffi to select Your DAY CYCLE:
SqlCqLl th s stat on wi I
operate every daySelect 2 this station willoperate every 2nd daySgleqllthis stalion w ll
operate every 3d day
to advance to lhe next Program step
to advance to the next program step IEE
E@;.v.:
GENERAL INFORMATION
Baltery replacement.
As soon as the low battery indicator BATT llashes, the 9V battery must be replaced.
After battery disconnection the program will remain in memory for 10 seconds until
reconnection to the new battery.
0perating conditions.
The controller is designed for outdoor operatlon. However it is recommended to place it in aprotected area.
Keep the cover closed at all times,
ln winter, the controller can be removed from the valve and stored indoors for better
protection, Only the actuator wires should be disconnected.
By keeping the battery connected, the program will remain in memory until reconnection ofthe controller.
Manual ovenide.
The manual override allows you to open or close the valve mechanically. The actuator is
factory set on AUTO. _ . .
. - . . - - . '
i ' . - ' . . . . . .
TO OPEN THE VALVE: turn the arrow
COUNTER-CLOCKWISE, 1 804 and return
it back to AUTO; the valve is open.
TO CLOSE THE VALVE: Turn the arrow
CLOCKWISE 180a and return it back
to AUTO; the valve is closed.
TO'LOCK" THE VALVE: lf you wish
to keep the valve in either OPEN or
CLOSED position, keep the arrowpointed in 180" d:reclon without returning
it to AUTO in any of the 2 previous steps.
TO RESUIVE AUTO[/ATIC OPERATION:return the arrow to AUTO.