1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 1 STAFF RECOMMENDATION 1804 Boscobel Street March 21, 2012 Application: New Construction Rear Addition District: Lockeland Springs-East End Neighborhood Conservation Zoning Overlay Council District: 06 Map and Parcel Number: 08314032200 Applicant: Jeff Livingston Project Lead: Sean Alexander, [email protected] Description of Project: The applicant is proposing to construct a rear addition to a contributing structure. The addition will set in from the original structure on both sides and will match the height of the existing roof. The materials of the addition will be: cement- fiber siding, asphalt shingle roof, split-faced block foundation, and wood windows. Recommendation Summary: Staff recommends approval of the proposed rear addition with the condition that staff approve final material selections, as meeting the guidelines for New Construction and Additions in the Lockeland Springs-East End Neighborhood Conservation Zoning Overlay. Attachments A: Photographs B: Site Plan C: Elevations

Upload: others

Post on 21-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 1

STAFF RECOMMENDATION

1804 Boscobel Street

March 21, 2012

Application: New Construction – Rear Addition

District: Lockeland Springs-East End Neighborhood Conservation Zoning Overlay

Council District: 06

Map and Parcel Number: 08314032200

Applicant: Jeff Livingston

Project Lead: Sean Alexander, [email protected]

Description of Project: The applicant is proposing to construct a

rear addition to a contributing structure. The addition will set in

from the original structure on both sides and will match the height

of the existing roof. The materials of the addition will be: cement-

fiber siding, asphalt shingle roof, split-faced block foundation, and

wood windows.

Recommendation Summary: Staff recommends approval of the

proposed rear addition with the condition that staff approve final

material selections, as meeting the guidelines for New Construction

and Additions in the Lockeland Springs-East End Neighborhood

Conservation Zoning Overlay.

Attachments

A: Photographs

B: Site Plan

C: Elevations

Page 2: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 2

Vicinity Map:

Aerial Map:

Page 3: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 3

Background: The house at 1804 Boscobel is a one-story Transitional Victorian with a

steep cross-gabled roof. Based on the architectural features present and the materials of

its construction, it is estimated to have been constructed circa 1910.

Applicable Design Guidelines:

II.B. New Construction

1. Height

New buildings must be constructed to the same number of stories and to a height which is

compatible with the height of adjacent buildings.

2. Scale

The size of a new building; its mass in relation to open spaces; and its windows, doors,

openings, and porches should be visually compatible with the surrounding buildings.

3. Setback and Rhythm of Spacing

The setback from front and side yard property lines established by adjacent buildings must be

maintained. When a definite rhythm along a street is established by uniform lot width and

building width, infill new buildings should maintain the rhythm.

4. Relationship of Materials, Textures, Details, and Material Colors

The relationship and use of materials. textures, details, and material color of a new building's

public facades shall be visually compatible with and similar to those of adjacent buildings, or

shall not contrast conspicuously.

5. Roof Shape

The roofs of new buildings shall be visually compatible, by not contrasting greatly, with the

roof shape and orientation of surrounding buildings.

6. Orientation

The site orientation of new buildings shall be consistent with that of adjacent buildings and

shall be visually compatible. Directional expression shall be compatible with surrounding

buildings, whether that expression is vertical, horizontal, or non-directional.

7. Proportion and Rhythm of Openings

The relationship of width to height of windows and doors, and the rhythm of solids (walls) to

voids (door and window openings) in new buildings shall be visually compatible with the

surrounding buildings.

8. Outbuildings

a. Garages and storage buildings should reflect the character of the existing house and

surrounding buildings and should be compatible in terms of height, scale, roof shape,

materials, texture, and details.

9. Appurtenances

Appurtenances related to new buildings, including driveways, sidewalks, lighting, fences,

and walls, shall be visually compatible with the environment of the existing buildings and

sites to which they relate.

10. Additions to Existing Buildings

a. New additions to existing buildings should be kept to a minimum and should be compatible

in scale, materials, and texture; additions should not be visually jarring or contrasting.

Page 4: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 4

A new addition should be constructed in such a manner that if the addition were to be

removed in the future, the essential form and integrity of the original structure would be

unimpaired.

Connections should, as much as possible, use existing window and door openings rather

than remove significant amounts of rear wall material.

b. Additions should not be made to the public facades of existing buildings. Additions may

be located to the rear of existing buildings in ways which do not disturb the public facades.

Placement

Additions should be located at the rear of the existing structure.

Additions should be physically distinguished from the historic building and generally fit

within the shadow line of the existing building.

Connections to additions should, as much as possible, use existing window and door

openings rather than remove significant amounts of rear wall material.

In rare and special circumstances an addition may rise above or extend wider than the

existing building, however, no part of any addition may simultaneously rise higher and

extend wider than the existing building.

When a lot width exceeds 60’ or the standard lot width on the block, it may be

appropriate to add a side addition to a historic structure. The addition should set back

from the face of the historic structure and should be subservient in height, width and

massing to the historic structure.

Side additions should be narrower than half of the historic building width and

exhibit a height of at least 2’ shorter than the historic building.

To deemphasize a side addition, the roofing form should generally be a hip or

side-gable roof form.

Additions taller than existing building

Foundation

Foundation walls should set in from the existing foundation at the back edge of the

existing structure by one foot for each story or half story. Exception: When an

addition is a small one-room deep (12’ deep or less) addition that spans the width of

the structure, and the existing structure is masonry with the addition to be wood (or

appropriate substitute siding) since the change in materials will allow for a minimum

of a four inch (4”) inset.

Foundation height should match or be lower than the existing structure.

Foundation lines should be visually distinct from the predominant exterior wall material.

Examples are a change in materials or a change in masonry coursing, etc.

Roof

The height of the addition's roof and eaves must be less than or equal to the existing

structure.

Visually evident roof slopes should match the roof slopes of the existing structure, and

roof planes should set in accordingly for rear additions.

Skylights should not be located on the front-facing slope of the roof. Skylights should be

flat (no bubble lenses) with a low profile (no more than six inches tall) and only be

installed behind the midpoint of the building.)

c. Additions must not imitate earlier styles or periods of architecture.

Contemporary designs for additions to existing properties are not discouraged when such

additions do not destroy significant historical, architectural, or cultural material; and when

Page 5: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 5

such design is compatible, by not contrasting greatly, with the size, scale, color, material, and

character of the property, neighborhood, or environment.

d. The creation of an addition through the enclosure of a front facade porch is inappropriate

and should be avoided.

Additions should following all New Construction guidelines.

Analysis and Findings:

The applicant is proposing to enlarge the structure with a rear addition.

Scale, Massing

The original structure has an asymmetrical “Queen Anne” floorplan, roughly thirty-five

feet (35’) wide and forty-two feet (42’) long. The addition will be twenty-six feet (26’)

wide and will increase the length by twenty-seven feet (27’). The addition will set in

from the walls of the existing structure by one foot (1’) on the left and one foot, seven

inches (1’-7”) on the right. The right side wall will match the location of an earlier

addition, which is likely a porch that has been enclosed. Staff finds this massing to be

subordinate to that of the original structure and to meet guidelines II.B.2, II.B.10.a, and

II.B.10.b.

Height, Roofs

Although the existing structure is one story, the addition has been designed with a lower

floor level that allows for the addition of an upper half-story, yet keeps the overall height

equal to that of the existing roof. The upperstory roof will be a side-oriented gable with a

6:12 pitch, connecting to the rear of the existing cross-gabled roof with a “saddle” that is

one foot (1’) lower. The saddle roof will match the 12:12 pitch of the existing roof on the

left side and will have a 3:12 pitch on the right. While this pitch is significantly lower

than the existing roof, it will be obscured behind the peak of the existing gable. The 6:12

roof pitch is similar to the roofs of many surrounding historic houses is appropriate in this

instance because it is also largely obscured behind the original side gable, and because it

begins nearly fifty feet (50”) behind the front of the structure. Staff finds the roofs to

meet guideline II.B.5. By matching and being subordinate to the existing structure, Staff

finds the height of the addition to be compatible and to meet guidelines II.B.1, II.B.10.a,

and II.B.10.b.

Materials, Windows, Orientation

The addition will be clad with smooth-faced cement-fiber siding with a five inch (5’)

exposure. The foundation will be split-faced concrete block and the roof will be asphalt

shingles matching the color of the existing roof. These materials are compatible with

surrounding houses, and meet guideline II.B.4 and II.B.10.a. A belt course on the

addition at the height of the original eave line will help to reduce the perceived height of

the addition and reinforce its horizontal orientation, meeting guideline II.B.7.

Page 6: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 6

The windows will be wood windows with four inch (4”) wooden flat casings, spaced no

greater than eight feet (8’) between any openings. The majority of new windows will be

one-over-one double-hung windows, roughly twice their width in height, which is typical

of historic windows. Two windows on each side of the addition will be square or

“letterbox” shaped, and fixed. Since these windows are towards the rear of the addition,

and set in from the outer edges of the house, they will be only minimally visible and will

not contrast greatly with the surrounding historic houses. Staff finds the proposed

window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the

design guidelines, final material and window selections should be approved by staff.

Recommendation:

Staff recommends approval of the proposed rear addition with the condition that staff

approve final material selections, as meeting the guidelines for New Construction and

Additions in the Lockeland Springs-East End Neighborhood Conservation Zoning

Overlay.

Page 7: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 7

Page 8: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 Boscobel Street Metro Historic Zoning Commission, March 21, 2012 8

1804 Boscobel Street, front.

1804 Boscobel Street, rear.

Page 9: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

1804 BOSCOBEL SITE PLAN

NEW

GARAGE

1" = 20'

EXISTING

HOUSE

ADDITION

10'-0

"

EXISTING CITY SIDEWALK

EXISTING RETAINING WALL 19'-6

1/4

"

DN

EXISTING ALLEY

REPAIR EXISTING 4'-0" WALK TO HOUSE

EXISTING GRASS

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 10: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

NEW SHED ROOF

3:12 SLOPE

EXISTING ROOFSEXISTING

ROOFS

EXISTING ROOF

NEW ROOF, 6:12 SLOPE

NEW SHED ROOF,

3:12 SLOPE

NEW GABLE ROOF

EXISTING ROOF

1804 BOSCOBEL - ROOF PLAN1/8" = 1'-0"

NEW ROOF, SLOPE TO

MATCH EXISTING AND

1'-0" LOWER THAN

EXISTING

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 11: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

UP

DN

EXISTING

PORCH

1804 BOSCOBEL

30'-5" EXISTING

26'-1 1/2"

LIVING

DINING

KITCHEN

MASTERBEDROOM

MASTER

CLOSET

24'-0

"

BEDROOM 2

FULL

BATH

MUD ROOM

LAUNDRY

DEN

PATIO

1st FLOOR PLAN 1/8" = 1'-0"

CLOS

CLOS

HIS

HERS

SH

WR

13'6" X 14'

10' X 14'6"

14' X 13'4"

10' X 14'

PA

NT

RY

R.A

.16'6" X 13"

10' X 9"

1ST FLOOR: 1610 SQ FT2ND FLOOR: 489 SQ FT

TOTAL: 2099 SQ FT

16'-10 1/2"9'-3"

20'-1

0"

EX

IST

ING

CO

NS

TR

UC

TIO

NN

EW

CO

NS

TR

UC

TIO

N

NE

W C

ON

ST

RU

CT

ION

EX

IST

ING

CO

NS

TR

UC

TIO

N

EXISTING

STEP

LINE OF

EXISTING

HOUSE

1'-0"

1'-6 3/4"

48'-9

"

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 12: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

DN

BEDROOM 3

11' X 16'

BONUS

BATH

1804 BOSCOBEL - 2ND FLOOR PLAN

RIDGE OF

ROOF

6' HIGH WALL

6'0" walls

1/8" = 1'-0"

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 13: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

First Floor0"

1804 BOSCOBEL FRONT ELEV1/8" = 1'-0"

4" TRIM AT CORNERS

FIBERCEMENT, 5" LAP SIDING

EXISTING FOUNDATION TO REMAIN

EXISTING COLUMNS

TO REMAIN

EXISTING FRONT PORCH.

EXISTING ROOF,

ARCHITECTURAL SHINGLES

EXISTING CHIMNEY TO REMAIN

EXISTING WINDOWS TO

REMAIN

EXISTING VENT TO REMAIN

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 14: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

First Floor0"

1804 BOSCOBEL LEFT ELEV

NEW 1ST-2'-6"

Second Floor7'-6"

6

12

NEW ROOFS,

ARCHITECTURAL

SHINGLES

3

12

1/8" = 1'-0"

EXISTING WALL,

ADD 5" LAP

SIDING

EXISTING

COLUMNS TO

REMAIN

EXISTING FOUNDATION AND

FRONT PORCH TO REMAIN

EXISTING ROOF,

ARCHITECTURAL SHINGLES

EXISTING CHIMNEY TO REMAIN

NEW 2'-0" X 2'-0" WD FIXED

WINDOWS

EXISTING WINDOWS

EXISTING ROOF, ARCHITECTURAL

SHINGLES

FIBERCEMENT 5'"

LAP SIDING

NEW FOUNDATION SPLIT FACE

CONC BLOCK

NEW 1'-4" X 3'-0"

WD DH WINDOW

NEW 2'-4" X 5'-2" DH

WD WINDOW FOR

EGRESS

1 x 10 BAND

EXISTING DOOR

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 15: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

First Floor0"

1804 BOSCOBEL REAR ELEV

NEW 1ST-2'-6"

Second Floor7'-6"

EXISTING ROOF,

ARCHITECTURAL

SHINGLES

NEW ROOF,

ARCHITECTURAL

SHINGLES

3

12

EXISTING ROOF

1/8" = 1'-0"

4" TRIM TYP AT

CORNERS

FIBERCEMENT 5" LAP

SIDING

NEW 2'-0" X 4'-2" WD DH WINDOW

NEW 2'-0 ' X 4'-2" WD DH WINDOW

1 X 10 BAND

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT

Page 16: Nashville.gov - Historic Zoning Commission - SR 1804 Boscobel...window pattern to meet guidelines II.B.4 and II.B.7. To ensure compliance with the design guidelines, final material

First Floor0"

1804 BOSCOBEL RIGHT ELEV

NEW 1ST-2'-6"

Second Floor7'-6"

EXISTING CHIMNEY

EXISTING ROOFS,

ARCHITECTURAL SHINGLES

NEW ROOFS,

ARCHITECTURAL

SHINGLES

NEW FOUNDATION,

SPLIT FACE CMU

EXISTING FOUNDATION

1/8" = 1'-0"

NEW 2'-0" X 2'-0" WD

FIXED WINDOWS

EXISTING WINDOWS

FIBERCEMENT 5'"

LAP SIDING

NEW 3'-0" X 1'-0" WD FIXED WINDOW

3

12

6

12

NEW 2'-8" X 5'-2" WD DH WINDOW

NEW ROOF,

ARCH.

SHINGLES

NEW 2'-4" X 5'-2" DH WD

WINDOW FOR EGRESS

4" TRIM @ CORNERS

1'-0 1

/2"

1'-0 3

/4"

1'-7 1

/8"

1 X 10 BAND

PRODUCED BY AN AUTODESK STUDENT PRODUCTP

RO

DU

CE

D B

Y A

N A

UT

OD

ES

K S

TU

DE

NT

PR

OD

UC

TPRODUCED BY AN AUTODESK STUDENT PRODUCT

PR

OD

UC

ED

BY

AN

AU

TO

DE

SK

ST

UD

EN

T P

RO

DU

CT