© grimm and parker, p.c. 2014 list of drawings vicinity ... · detail number sheet number detail...
TRANSCRIPT
B101a
0
A101
1SIM
DEPT.#
#
GRID LINES
SECTIONS
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAILS IN PLAN/SECTION
ROOM NUMBER
DOOR NO. ON PLAN
H.M. FRAME NO.ON PLAN
REVISION: TYPE =A.S.I/P.R./C.C.D./ADD.
CASEWORK(FURNISHING PLANS ONLY)
ALUM. FRAME/WINDOWTYPE
WALL TYPE
#-#.#
#
#
# # INTERIOR ELEVATION
DETAIL NUMBER
SHEET NUMBER
A3
ROOM NAME
##
EARTH
GRAVEL
CONCRETE
CONCRETE MASONRY UNITS
SOLID CONCRETE MASONRY UNITS
BRICK
WOOD-FINISHED
WOOD ROUGH
PLYWOOD
GYPSUM BOARD
ACOUSTIC TILE
STEEL - LARGE SCALE
CAST STONE
ALL METALS - SMALL SCALE
GLASS - LARGE SCALE
BATT INSULATION
RIGID INSULATION
CERAMIC TILE
CARPET
Above finished floor AFFAcoustic ACSTAcoustic Panel Ceiling APCAddendum ADDAlternate ALTAluminum ALAngle LApproximate APPROXArchitecture, architectural ARCHAsbestos ASBAsphalt ASPHAssistant ASSTAssociation ASSNAutomatic AUTOAverage AVGBase plate BPBasement BSMTBeam BMBearing BRGBedroom BRBenchmark BMBoard BDBoiler BLRBottom BOTBrick BRKBuilding line BLBuilding BLDGBuilt-up-roof BURCabinet CABCarpet CPTCatalog CATCeiling height CHCeiling CLGCenter CTRCenterline CLCeramic Tile CTCeramic CERChalkboard CBClear CLRCloset CLOCoated CTDCold rolled CRColumn COLCompany COComposition COMPConcrete Masonry Unit CMUConcrete CONCConstruction joint CJConstruction CONSTR"Continue, Continuous" CONTCorridor CORRCountersink CSKCubic CUCurve(d) CRVDampproofing DPDegree DEGDepartment(al) DEPTDetail DETDiagonal DIAGDiameter DIADimension DIMDishwasher DWDispenser DISPDoor DRDouble DBLDouble-hung DHDown DNDownspout DSDrain DRDrawing DWGEach EAEast EElectric Water Cooler EWC"Electric, electrical" ELECElevation ELElevator ELEVEngineer ENGREntrance ENTREqual EQEquipment EQUIPExhaust EXHExisting EXISTExpansion joint EXP JTExposed EXPExterior EXTFabricate FABFace of Stud F. OF S.Fan Coil Unit FCUFiberglass-reinforced plastics FRPFinish FINFinished Floor FFFire Extinguisher FEFire Extinguisher & Cabinet FECFire Retardant Treated FRTFireproof FPRFFixture FXTRFlange FLGFlashing FLFloor FLFloor drain FDFlooring FLGFluorescent FLUOR
Footing FTGFoundation FDNFurnish(ed), furniture FURNFurring FURRGage (gauge) GAGalvanize(d) GALVGalvanized Iron GALVIGlazed Wall Tile GWTGrab Bar GBGrade GRGravel GVLGypsum Wallboard GWBGypsum GYPHandicapped HCHardware HDWHeating ventilating and HVACair conditioningHeight HGTHigh Point HPTHigh Performance HPHigh Performance Coating HPCHollow Metal HMHorizontal HORIZInclude(d), inclusive INCLIncorporated INCInformation INFOInside diameter IDInstall(ed), installation INSTLInsulation INSULInterior INTJanitor JANJoint JTJoist J, JSTJunction box JBKnock down KDLaboratory LABLavatory LAVLeft Hand LHLeft LLength LGLevel LVLLight LTMachine MACHMaintenance MAINTManager MGRManual MNLManufacturing MFGMarkerboard MBMasonry opening MOMasonry MSNRYMaster bedroom MBRMaterial MATLMaximum MAXMechanical MECHMembrane MEMBMen MMetal MET, MTLMezzanine MEZZMinimum MINMirror MIRMiscellaneous MISCMounted MTDMounting MTGNecessary NECNoise-reduction coefficient NRCNominal NOMNon Combustible NC, NONCOMNorth NNot in Contract NICNot to scale NTSNot available NANumber NOOffice OFFOn center OCOpening OPNGOpposite OPPOutside diameter ODOverall OAOverhead OVHDPage PPainted PTDPair PRPanel PNLPartition PTNPercent PCTPerforate(d) PERFPermanent PERMPerpendicular PERPPiece PCPlastic Laminate PLAMPlastic Laminate PLAS.LAMPlate PLPlumbing PLMBPlywood PLYWDPoint PTPolyvinyl chloride PVCPrecast PRCSTPrefabricated PREFABPreliminary PRELIMPreparation, prepare PREPProgram PRGMProjection Screen PSProjector Board PB
Project PROJProperty PROPPublic Address PAQuality control QCQuality QUALQuantity QTYQuarry Tile QTRadius RADRain Leader RLReceived RCVDReceptacle RCPTReceptionist RECPTRecess(ed) RECRefer, reference REFRefrigerate, refrigerator REFRReinforce REINFReinforced concrete RCRemove RMVRepair RPRRequired REQDRevise, revision REVRight hand RHRoad RDRoof Drain RDRoof RFRoofing RFGRoom RMRubber tile floor RTFRubber RBRSchedule SCHEDSchematic SCHEMSection SECTService SVCE"Sheet, sheeting" SHTShower SHSiding SDGSimilar SIMSlope SLSound-transmission class STCSouth SSpeaker SPKRSpecification SPECSprinkler SPRSquare SQStainless steel SSStandard STDStandpipe SPSteel STLStorage STORStructural Glazed Facing Tile SGFTStructural, structure STRUCTSubstitute SUBSTSurface SURFSuspend(ed) SUSPSwitch SWSymmetrical SYMSystem SYSTackboard TBTackstrip TSTelephone TELTelevision TVTemporary TEMPTerrazzo TERThick THKThrough THRUToilet TTongue and groove T>op and bottom T&BTop chord TCTop of Masonry Parapet TMPTop of Bearing TOFBTop of Steel T.O.S.Topping TOPGTotal TOTTransformer XFMRTransom TRTransparent TRANSTread TRDThreshold THRESHTypical TYPUnderground UGUnderwriters Laboratories ULUnfinished UNFUnit Ventilator UVUnless Otherwise Noted UONUrinal URUS Gypsum Company USGVertical VERTVestibule VEST, VVinyl Reducing Strip VRSVinyl Composite Tile VCTVinyl asbestos tile VATWardrobe WARDWater closet WCWaterproof WPWeight WTWelded WLDWelded Wire Mesh WWMWith W/Without W/OWomen WWood WDWrought Iron WI
123456789101112131415161718
11720 B
eltsvill
e D
rive
Suite 6
00
Calv
ert
on,
MD
20705
Tel: 3
01.5
95.1
000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rim
mandpark
er.
com
TS
TITL
E S
HE
ET
LANS
DOWN
E ELE
MENT
ARY S
CHOO
L23
01 AL
MA R
OAD,
BALT
IMOR
E, MD
11/17/16BID SET
GP #21541
LIST OF DRAWINGSK103 PLUMBING ROUGH-IN PLAN
K104 ELECTRICAL ROUGH-IN PLAN
K501 EXHAUST CANOPY DETAILS
STRUCTURAL
S-0.1 GENERAL NOTES
S-0.2 INSPECTION TABLES
S-1.1A FOUNDATION AND SLAB ON GRADE PLAN - AREA A
S-1.1B FOUNDATION AND SLAB ON GRADE PLAN - AREA B
S-1.1C FOUNDATION AND SLAB ON GRADE PLAN - AREA C
S-1.2A SECOND FLOOR AND LOW ROOF FRAMING PLAN - AREA A
S-1.2B SECOND FLOOR AND LOW ROOF FRAMING PLAN - AREA B
S-1.2C SECOND FLOOR AND LOW ROOF FRAMING PLAN - AREA C
S-1.3A HIGH ROOF FRAMING PLAN - AREA A
S-1.3B HIGH ROOF FRAMING PLAN - AREA B
S-1.3C HIGH ROOF FRAMING PLAN - AREA C
S-2.1 BRACED FRAME ELEVATIONS AND DETAILS
S-3.1 TYPICAL DETAILS FOUNDATION AND SLAB ON GRADE
S-3.2 TYPICAL DETAILS STRUCTURE
S-3.3 TYPICAL DETAILS MASONRY
S-4.1 SECTIONS
S-4.2 SECTIONS
S-5.1 SECTIONS
S-5.2 SECTIONS
S-5.3 SECTIONS
S-5.4 SECTIONS
S-5.5 SECTIONS
S-5.6 SECTIONS
MECHANICAL
ME-0.1 SITE PLAN, VICINITY MAP, PART PLANS, AND DETAIL
M-0.1 MECHANICAL SYMBOLS AND ABBREVIATIONS
M-1.1A PARTIAL FIRST FLOOR PLAN - AREA A - HVAC
M-1.1B PARTIAL FIRST FLOOR PLAN - AREA B - HVAC
M-1.1C PARTIAL FIRST FLOOR PLAN - AREA C - HVAC
M-1.2C PARTIAL SECOND FLOOR PLAN - AREA C - HVAC
M-1.3 ROOF PLAN - HVAC
M-2.1A PARTIAL FIRST FLOOR PLAN - AREA A - PIPING
M-2.1B PARTIAL FIRST FLOOR PLAN - AREA B - PIPING
M-2.1C PARTIAL FIRST FLOOR PLAN - AREA C - PIPING
M-2.2C PARTIAL SECOND FLOOR PLAN - AREA C - PIPING
M-4.1 PART PLANS - HVAC
M-4.2 PART PLANS - HVAC
M-5.1 DETAILS AND DIAGRAMS
M-5.2 DETAILS AND DIAGRAMS
M-5.3 DETAILS AND DIAGRAMS
M-6.1 SCHEDULES
M-6.2 SCHEDULES
M-6.3 SCHEDULES
M-6.4 SCHEDULES
M-7.1 AUTOMATIC TEMPERATURE CONTROLS
M-7.2 AUTOMATIC TEMPERATURE CONTROLS
M-7.3 AUTOMATIC TEMPERATURE CONTROLS
M-7.4 AUTOMATIC TEMPERATURE CONTROLS
PLUMBING
P-0.1 LEGEND, SYSMBOLS AND ABBREVIATIONS
P-1.1A PARTIAL FIRST FLOOR PLAN - AREA A - PLUMBING
P-1.1B PARTIAL FIRST FLOOR PLAN - AREA B - PLUMBING
P-1.1C PARTIAL FIRST FLOOR PLAN - AREA C - PLUMBING
P-1.2C PARTIAL SECOND FLOOR PLAN - AREA C - PLUMBING
P-1.3 ROOF PLAN - PLUMBING
P-4.1 PART PLANS
P-4.2 PART PLANS
P-4.3 PART PLANS
P-5.1 DETAILS AND DIAGRAMS
P-5.2 DETAILS AND DIAGRAMS
P-5.3 DETAILS AND DIAGRAMS
P-6.1 SCHEDULES
FIRE PROTECTION
FP-1.1 FIRST FLOOR PLAN AND NOTES - FIRE PROTECTION
FP-1.2 SECOND FLOOR PLAN, DETAILS AND DIAGRAMS - FIRE PROTECTION
ELECTRICAL
E-0.1 SYMBOLS LIST AND ABBREVIATIONS
E-1.1A FIRST FLOOR PLAN - AREA A - LIGHTING
E-1.1B FIRST FLOOR PLAN - AREA B -LIGHTING
E-1.1C FIRST FLOOR PLAN - AREA C -LIGHTING
E-1.2C SECOND FLOOR PLAN - AREA C - LIGHTING
E-2.1A FIRST FLOOR PLAN - AREA A - POWER
E-2.1B FIRST FLOOR PLAN - AREA B - POWER
E-2.1C FIRST FLOOR PLAN - AREA C - POWER
E-2.2C SECOND FLOOR PLAN - AREA C - POWER
E-2.3 ROOF PLAN
E-3.1A FIRST FLOOR PLAN - AREA A - FIRE ALARM
E-3.1B FIRST FLOOR PLAN - AREA B - FIRE ALARM
E-3.1C FIRST FLOOR PLAN - AREA C - FIRE ALARM
E-3.2C SECOND FLOOR PLAN - AREA C - FIRE ALARM
E-4.1 PART PLANS
E-5.1 DETAILS
E-5.2 DETAILS
E-5.3 DETAILS
E-6.1 DIAGRAMS
E-6.2 SCHEDULES
E-6.3 SCHEDULES
E-6.4 SCHEDULES
E-6.5 SCHEDULES
E-7.1 LIGHTING FIXTURE SCHEDULE
E-7.2 LIGHTING CONTROLS SCHEME SCHEDULES
E-7.3 LIGHTING CONTROLS DIAGRAMS
E-7.4 LIGHTING CONTROLS DIAGRAMS
E-7.5 LIGHTING CONTROLS DIAGRAMS
E-8.1 ALTERNATES
TELECOMMUNICATIONS
T-0.1 SYMBOLS, LEGENDS AND ABBREVIATIONS - TELECOM
T-0.2 SITE PLAN - TELECOM
T-1.1A PARTIAL FIRST FLOOR PLAN - AREA A - TELECOM
T-1.1B PARTIAL FIRST FLOOR PLAN - AREA B - TELECOM
T-1.1C PARTIAL FIRST FLOOR PLAN - AREA C - TELECOM
T-1.2A PARTIAL SECOND FLOOR PLAN - AREA A - TELECOM
T-1.2B PARTIAL SECOND FLOOR PLAN - AREA B - TELECOM
T-1.2C PARTIAL SECOND FLOOR PLAN - AREA C - TELECOM
T-4.1 RISERS - TELECOM
T-5.1 DETAILS - TELECOM
T-5.2 DETAILS - TELECOM
T-5.3 DETAILS - TELECOM
T-5.4 DETAILS - TELECOM
T-5.5 DETAILS - TELECOM
T-5.6 DETAILS - TELECOM
T-5.7 DETAILS - TELECOM
LIST OF DRAWINGS
TS TITLE SHEET
CIVIL
C-0.1 KEY PLAN
C-0.2 GENERAL NOTES
C-0.3A EXISTING CONDITIONS/DEMOLITION PLAN - PHASE 1
C-0.3B EXISTING CONDITIONS/DEMOLITION PLAN - PHASE 1
C-0.4A PHASING PLAN - PHASE 1
C-0.4B PHASING PLAN - PHASE 2
C-1.1 PROPOSED SITE AND GRADING PLAN - PHASE 1
C-1.2 PROPOSED SITE AND GRADING PLAN - PHASE 2
C-1.3 SITE DETAILS
C-1.4 SITE DETAILS
C-1.5 SITE DETAILS
C-1.6 SITE DETAILS
C-1.7 SITE DETAILS
C-1.8 SITE DETAILS
C-2.1 PAVING, STRIPING AND SIGNAGE PLAN
C-3.1 GEOMETRY PLAN - PHASE 1
C-3.2 GEOMETRY PLAN - PHASE 2
C-4.1 UTILITY PLAN
C-4.2 UTILITY PROFILES
C-4.3 UTILITY PROFILES
C-4.4 UTILITY PROFILES
C-4.5 UTILITY PROFILES
C-4.6 UTILITY PROFILES
C-5.1 STORM DRAIN DRAINAGE AREA MAP
C-6.1 EROSION AND SEDIMENT CONTROL PLAN - PHASE 1
C-6.2 EROSION AND SEDIMENT CONTROL PLAN - PHASE 2
C-6.3 EROSION AND SEDIMENT CONTROL - TRAP NO. 1 INSET PLAN
C-6.4 EROSION AND SEDIMENT CONTROL - TRAP NO. 2 INSET PLAN
C-6.5 EROSION AND SEDIMENT CONTROL - TRAP NO. 3 INSET PLAN
C-6.6 EROSION AND SEDIMENT CONTROL - TRAP NO. 4 INSET PLAN
C-6.7 TEMPORARY GABION OUTLET STRUCTURE INSET PLAN
C-6.8 EROSION AND SEDIMENT CONTROL DETAILS
C-6.9 EROSION AND SEDIMENT CONTROL DETAILS
C-6.10 EROSION AND SEDIMENT CONTROL DETAILS
C-6.11 EROSION AND SEDIMENT CONTROL DETAILS
C-6.12 EROSION AND SEDIMENT CONTROL NOTES
C-6.13 EROSION AND SEDIMENT CONTROL NOTES
C-7.1 STORMWATER MANAGEMENT PLAN
C-7.2 STORMWATER MANAGEMENT DETAILS
C-7.3 STORMWATER MANAGEMENT DETAILS
C-7.4 STORMWATER MANAGEMENT DETAILS
C-7.5 STORMWATER MANAGEMENT NOTES
C-7.6 STORMWATER MANAGEMENT NOTES
C-7.7 STORMWATER MANAGEMENT NOTES AND CERTIFICATIONS
C-7.8 STORMWATER MANAGEMENT BORING LOGS
C-8.1 LANDSCAPE PLAN
C-8.2 LANDSCAPE DETAILS
C-9.1 FOREST CONSERVATION PLAN
C-9.2 FOREST CONSERVATION NOTES AND DETAILS
C-10.1 PUBLIC WATER PLAN
C-10.2 PUBLIC SANITARY SEWER AND RIGHT-OF-WAY PLAN
C-10.3 PUBLIC STORM DRAIN PLAN - 1
C-10.4 PUBLIC STORM DRAIN PLAN - 2
C-10.5 PUBLIC STORM DRAIN PLAN - 3
ARCHITECTURAL
A-0.1 FIRST FLOOR CODE STUDY
A-0.2 SECOND FLOOR CODE STUDY
A-0.3 FIRST FLOOR OVERALL PLAN
A-0.4 SECOND FLOOR OVERALL PLAN
A-0.5 OVERALL LAYOUT PLAN
A-0.6 ARCHITECTURAL SITE PLAN
A-0.7 SITE DETAILS
A-1.1A PARTIAL FIRST FLOOR PLAN - AREA A
A-1.1B PARTIAL FIRST FLOOR PLAN - AREA B
A-1.1C PARTIAL FIRST FLOOR PLAN - AREA C
A-1.2B PARTIAL SECOND FLOOR PLAN - AREA B
A-1.2C PARTIAL SECOND FLOOR PLAN - AREA C
A-1.3 ROOF PLAN
A-1.4 ROOF DETAILS
A-1.5 ROOF DETAILS
A-2.1 EXTERIOR ELEVATIONS
A-2.2 EXTERIOR ELEVATIONS
A-2.3 EXTERIOR ELEVATIONS
A-2.4 EXTERIOR ELEVATIONS
A-2.5 OVERALL AXONOMETRIC VIEWS
A-3.1 FINISH SCHEDULE
A-3.2 DOOR SCHEDULE
A-3.3 HEAD, SILL, AND JAMB DETAILS
A-3.4 FRAME ELEVATIONS
A-3.5 FRAME ELEVATIONS
A-3.6 FRAME ELEVATIONS - INTERIOR
A-3.7 FRAME ELEVATIONS - INTERIOR
A-3.8 WALL TYPES AND TERMINATION DETAILS
A-3.9 STOREFRONT AND CURTAINWALL DETAILS
A-4.1 BUILDING SECTIONS
A-4.2 BUILDING SECTIONS
A-4.3 WALL SECTIONS
A-4.4 WALL SECTIONS
A-4.5 WALL SECTIONS
A-4.6 WALL SECTIONS
A-4.7 WALL SECTIONS
A-4.8 WALL SECTIONS
A-4.9 WALL SECTIONS
A-4.10 WALL SECTIONS
A-4.11 WALL SECTIONS
A-4.12 WALL SECTIONS
A-5.1 ENLARGED TOILET PLANS
A-5.2 STAIR PLANS AND SECTIONS
A-5.3 STAIR PLANS AND SECTIONS
A-5.4 STAIR DETAILS
A-5.5 TYPICAL DETAILS
A-5.6 PLAN DETAILS
A-5.7 PLAN DETAILS
A-6.1 INTERIOR ELEVATIONS
A-6.2 INTERIOR ELEVATIONS
A-6.3 INTERIOR ELEVATIONS
A-6.4 INTERIOR ELEVATIONS
A-6.5 INTERIOR ELEVATIONS
A-6.6 INTERIOR ELEVATIONS
A-7.1A PARTIAL FIRST FLOOR CEILING PLAN - AREA A
A-7.1B PARTIAL FIRST FLOOR CEILING PLAN - AREA B
A-7.1C PARTIAL FIRST FLOOR CEILING PLAN - AREA C
A-7.2B PARTIAL SECOND FLOOR CEILING PLAN - AREA B
A-7.2C PARTIAL SECOND FLOOR CEILING PLAN - AREA C
A-8.1 ALTERNATES
A-9.0 EQUIPMENT AND FURNISHING SCHEDULES
A-9.1A PARTIAL FIRST FLOOR FURNITURE PLAN - AREA A
A-9.1B PARTIAL FIRST FLOOR FURNITURE PLAN - AREA B
A-9.1C PARTIAL FIRST FLOOR FURNITURE PLAN - AREA C
A-9.2C PARTIAL SECOND FLOOR FURNITURE PLAN - AREA C
A-9.3 MILLWORK/INTERIOR DETAILS
KITCHEN
K101 KITCHEN EQUIPMENT PLAN
K102 BUILDING CONDITIONS & VENTILATION PLAN
B O A R D O F E D U C A T I O N
D E S I G N T E A M
MBU-516-17
PSC# 03.105.17
LANSDOWNE ELEMENTARY SCHOOL
BID SETNOVEMBER 17, 2016
2301 ALMA ROAD, BALTIMORE, MD
DRAWING KEY
SYMBOLS OF MATERIALS
ABBREVIATIONS
GRIMM + PARKER ARCHITECTS
KCI TECHNOLOGIES
COLUMBIA ENGINEERING, INC
JAMES POSEY ASSOCIATES, INC
NYIKOS ASSOCIATES
WRIGHT ENGINEERING
SUSTAINABLE DESIGN CONSULTING, LLC
FACILITY DYNAMICS
ARCHITECT
CIVIL ENGINEER
STRUCTURAL ENGINEER
MECHANICAL AND ELECTRICAL ENGINEER
FOOD SERVICE
TECHNOLOGY CONSULTANT
LEED CONSULTANT
COMMISSIONING AGENT
CHARLES McDANIELS, Jr. Chair
EDWARD J. GILLISS, Esq. Vice Chair
MICHAEL J. COLLINS
ANN MILLER
NICHOLAS C. STEWART, Esq.
S. DALLAS DANCE, Ph.D, Secretary-Treaurer DAVID UHLFELDER
KATHLEEN S. CAUSE STEPHEN L. VERCH, Esq.
MARISOL A. JOHNSON
ROMAINE N. WILLIAMS, Esq.
JUNE P. EATON DEEKSHA WALIA
GEOTECH ENGINEERS, INC GEOTECHNICAL ENGINEER
HENNING ASSOCIATES, INC ACOUSTICAL CONSULTANT
APPLIED ENVIRONMENTAL INDUSTRIAL HYGENIST
EHT TRACERIES HISTORIAN
FORELLA GROUP COST ESTIMATOR
SITE
VICINITY MAP
ERBSCHLOE CONSULTING SERVICES, INC HARDWARE CONSULTANT
DATE DESCRIPTION
2'-0"
ONE-PIECE FRONT
PUNCH HOLESFOR FAUCET
8'-6"
1"2'-0"
10"
2'-10
"
3"
1'-1"
2'-6"
ANGLE BRACKETSS/S WASTE LEVER(FULLY WELDED)
S/S UNDERSHELF W/2"TURN-UP @ REAR
PITCH
PITCH
1'-2"
ANGLE BRACKETSS/S WASTE LEVER
PITCH
PUNCH HOLESFOR FAUCETS
ONE-PIECE FRONT
S/S UNDERSHELF W/2"TURN-UP @ REAR (EA. END)
1'-3"
PITCH
2'-0"
2'-0"
1"
1"
2'-0"
9'-9"
2'-10
"
10"
3"
1'-1"
2'-6"
(FULLY WELDED)
6'-0"
1'-0"
& BOTH ENDS
S/S OVERSHELF W/2" TURN-UP @ REAR
S/S UNDERSHELF W/2"TURN-UP @ REAR
S/S UNDERSHELFW/2" TURN-UP
3'-0"
10"
6"
6'-0"
2'-6"
ASSEMBLYS/S DRAWERW/LOCK
@ REAR
ASSEMBLYS/S DRAWERW/LOCK
S/S DRAWERASSEMBLY
S/S UNDERSHELF
W/LOCK
8'-0"
2'-6"
3'-0"
10"
S/S DRAWERASSEMBLYW/LOCK
1'-2"-/+(VER.)
PREP SINK POT WASHING SINK WORKTABLEWORKTABLE12 19 2217
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
31b.
31a.
32
33
31b.
31a.
32
33
21
2813 14
29
13 14
19
18
131415
11
11
35
4
8 8
32
12
16
17
1
5
6
8 8
9 9
9
9
9 99 9
9
9 9
26
26
27
2731
31c.
31c.
31
35
SERVING#2
SERVING#1
REFRIGERATION UNITSMOUNTED ON ROOF SEEROOF PLAN SHEET NO.
M-1.3 FOR EXACTLOCATION.
BLDG OUTSIDESTORB112
GENERALFURNITURESTORAGE
B126
34
34
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
SERVICEB117
NON-FOODSTORAGE
B119
DRY STORAGEB120
LOCKERB115
TOILETB116
CAN WASHB114
PE - OUTDOOREQUIPMENTSTORAGE
B113
POT WASHINGB122
FOOD PREPB123
SERVING LINEB125
CAFETERIAB128
OFFICEB121
23
25
25
22
24
16
VEG.PREP
POT & PANWASHING
RECEIVINGB118
31d.
10
10
2
8 8 88
7 7 7 7
FZR. CLR.
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
30
KITCHEN EQUIPMENT PLANSCALE: 1/4"=1'-0"
THE USE OF SEALANTS IN FOOD SERVICE EQUIPMENT1. ALL SEALANTS MUST BE LISTED AS APPROVED BY THE NATIONAL SANITATION FOUNDATION (NSF) UNDER 51.
2. SEALANTS SHALL BE USED ONLY ON STRUCTURALLY SOUND JOINTS AND SEAMS.
3. SEALANTS MAY BE USED TO FILL SPACES AND OPENINGS SUCH AS, BUT NOT LIMITED TO, BLIND RIVET HEADS AND SLOT AND PHILLIPS HEAD SCREWS.
4. OPENINGS AROUND SERVICE AND UTILITY LINES SHOULD BE CLOSED INSOFAR AS PRACTICAL BY:A. COLLARS AND GROMMETS.B. FLEXIBLE FORM GASKETS.
SEALANTS MAY BE USED TO SEAL SERVICE AND UTILITY LINES TO WALL AND ADJACENT PIECES OF EQUIPMENT WHERE THE SPACING IS. CLOSED TO LESS THAN 1/8 OF INCH.
5. SEALANTS MAY NOT BE UTILIZED IN FOOD AND SPLASH CONTACT SURFACES, TO FILL OPEN SPACES, OR VOIDS WHICH RESULT DUE TO IMPROPER DESIGN OR FABRICATION. ANY OPENING IN EXCESS OF 1/8 INCH SHALL BE CONSIDERED EXCESSIVE AND MUST BE CLOSED USING PROPER FIELD JOINTS.
FABRICATION DETAILSSCALE: 1/2"=1'-0"
123456789101112131415161718
1172
0 Be
ltsvi
lle D
rive
Suite
600
Cal
verto
n, M
D 2
0705
Tel:
301.
595.
1000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rimm
andp
arke
r.com
K101
KITC
HEN
EQUI
PMEN
T PLA
N
LANSDO
WNE E
LEMENT
ARY SC
HOOL
2301 A
LMA RO
AD, BA
LTIMO
RE, MD
11/17/16BID SET
GP #21541
EQUIPMENT SCHEDULEITEM QTY. DESCRIPTION REMARKS
1 1 FLY FAN2 2 SHELVING3 1 MOP SINK & RACK W/(6) WALL HANGERS4 1 WALK-IN COOLER/FREEZER W/REMOTE TEMP. MONITORING5 1 COOLER REFRIGERATION SYSTEM OUTDOOR-MOUNTED ON ROOF6 1 FREEZER REFRIGERATION SYSTEM OUTDOOR-MOUNTED ON ROOF7 4 DUNNAGE RACK, MOBILE8 8 SHELVING, MOBILE9 11 SHELVING10 2 SIGNAGE (N.I.C.) - FURNISHED BY OWNER; CONTRACTOR INSTALLED11 2 DUNNAGE RACK12 1 PREP SINK13 3 HAND SINK14 3 SOAP & TOWEL DISPENSER (N.I.K.E.C.) - SPECIFIED BY ARCHITECT15 1 EYE WASH STATION16 2 PAN RACK CART, MOBILE17 1 WORKTABLE W/MANUAL CAN OPENER18 1 POT & PAN SHELVING, MOBILE19 1 POT WASHING SINK W/ OVERSHELF20 1 SPARE NUMBER21 1 BULK MILK COOLER, MOBILE22 1 WORKTABLE23 1 CONVECTION OVEN DOUBLE-DECK24 1 EXHAUST CANOPY25 2 HEATED TRANSPORT CABINET, MOBILE26 2 PASS-THRU REFRIGERATOR, MOBILE27 2 PASS-THRU HEATED CABINET, MOBILE28 1 ICE CREAM CABINET, MOBILE29 1 MILK COOLER, MOBILE30 1 MILK COOLER, MOBILE DUAL-ACCESS31 1 SERVING COUNTER
31a. 2 HOT FOOD COUNTER31b. 2 FROST TOP COUNTER31c. 2 SOLID TOP COUNTER31d. 1 CASHIER STAND32 2 ICE CREAM MERCHANDISER DROP-IN UNIT33 2 CASH REGISTER (N.I.C.) - FURNISHED BY OWNER34 2 CONDIMENT COUNTER, MOBILE35 2 UTILITY CART, MOBILE
(N.I.C.) - NOT IN CONTRACT
GENERAL HEALTH DEPARTMENT NOTATIONS1 ALL PIPING, CONDUIT, AND SIMILAR WILL BE EITHER LOCATED INSIDE A WALL OR INSTALLED WITH
A MINIMUM OF 3/4" SPACE FROM THE WALL OR SEALED TO THE WALL.2 ALL DOORS TO THE OUTSIDE WILL BE SELF-CLOSING AND RODENT-PROOF.3 A MINIMUM OF FIFTY (50) FOOT CANDLES OF SHIELDED LIGHT WILL BE PROVIDED AT ALL WORK
SURFACES, STORAGE AREAS, FOOD PREPARATION AREAS, UTENSIL WASHING AREAS, TOILETROOMS, LOCKER ROOMS, AND IN THE GARBAGE AND RUBBISH STORAGE AREAS.
4 ALL RESTROOM DOORS WILL BE SELF-CLOSING.5 ALL RESTROOMS WILL BE EQUIPPED WITH MECHANICAL EXHAUST VENTILATION SIZED AT A
MINIMUM RATE OF TWO (2) CUBIC FEET PER MINUTE PER SQUARE FOOT OF FLOOR AREA ANDEXHAUSTING DIRECTLY TO THE OUTSIDE.
6 ALL FLOOR MOUNTING EQUIPMENT WILL BE PLACED ON NATIONAL SANITATION FOUNDATION(NSF) APPROVED SIX (6) INCH LEGS, OR THE EQUIVALENT, AND PROPERLY SPACED FROMADJACENT EQUIPMENT OR WALLS; OR PLACED ON NSF APPROVED CASTERS, OR THEEQUIVALENT; OR PROPERLY SEALED TO ALL ADJACENT SURFACES. .
7 ALL COUNTER MOUNTED FOOD SERVICE EQUIPMENT WEIGHING IN EXCESS OF EIGHTY (80)POUNDS WILL BE MOUNTED ON NSF APPROVED FOUR (4) INCH HIGH LEGS.
8 ALL EXPOSED RAW WOOD WILL BE SEALED.9 ALL ANNULAR OPENINGS IN CONSTRUCTION WILL BE SEALED TO 1/32TH OF AN INCH.10 ALL AISLES WILL BE A MINIMUM OF THIRTY SIX (36) INCHES WIDE PER NATIONAL FIRE
PROTECTION ASSOCIATION 101.11 THE OUTSIDE STORAGE OF REFUSE WILL BE IN RODENT-PROOF CONTAINERS ON A PAVED
SURFACE.12 ALL SINK INSTALLATIONS WILL BE EQUIPPED WITH HOT AND COLD RUNNING WATER THROUGH A
MIXING VALVE OR COMBINATION FAUCET.13 ALL PAINTING WILL BE WITH LEAD-FREE, NON-METALLIC ENAMEL PAINT OR A HIGH QUALITY
VARNISH.14 WASTE WATER FROM ALL APPLICABLE FOOD SERVICE EQUIPMENT WILL BE INDIVIDUALLY
PLUMBED TO AN OPEN SITE DRAIN OR FLOOR SINK WITH A MINIMUM ONE INCH AIR GAP.
(N.I.K.E.C.) - NOT IN KITCHEN EQUIPMENT CONTRACT
DATE DESCRIPTION
12"
12"
12"
12"
7"
1'-0"+
CEILINGFINISHED
AS WALK-IN FASTEN TO FRONTBOTTOM RAIL SAME FINISH
FACE BY K.E.C.
FIELD VERIFY PANEL DIMENSION.WITH SAME FINISH AS WALK-IN.REMOVABLE CLOSURE PANEL
OF WALK-IN BOXFRONT FACE
CEILINGTERMINATE FIN.
FILL-IN EXCESSOF DEPRESSION WITHGROUT AFTER WALK-INIS ERECTED
4"2"
ASPHALT EMULSION ADHESIVEPERIMETER & JOINTS W/W/4" OVERLAP SEALED @10 MIL POLYETHELENE SHEET
HEATED THRESHOLDBY WALK-IN MFR.
FINISHEDFLOOR
WALK-INDOOR
EXPOSED SURFACES
WITH COVED BASE &
WIRE MESH FABRICTWO (2) LAYERS
SETTING BED BY
QUARRY TILE FLOOR& WALL PANEL BY
SEALANT
COVED BASE ALL
WALK-IN MFR.
EPOXY
PRE-FAB FLOOR
TILE CONTRACTOR
NOTE! SEE ARCHITECTURAL & STRUCTURALDRAWINGS FOR ADDITIONAL DETAILS.
-- BACK-FILL CURB OPENING W/HOT PITCH AFTER INSTALLATION
LEVEL IN BOTH DIRECTIONS
W/WATER-TIGHT SOLDERED JOINTS-- PROVIDE SHEET METAL HAT SECTION
-- PLATFORM TO BE 12" HIGH &
#20 GA. S/S TOP
NOTE!
ROOF LINE
2x12 FRAME(ALL SIDES)
SEALANT
2x6 @16" O.C.
3/4" PLYWD.DECKING
SEALANT
S/S SCREEN
#18 GA. S/SDUCT COVER
15"H.x15"x16"
DECKMETAL
PIPES
BY K.E.C.
INSULATIONBLDG.
NOTE! SEE ARCHITECTURAL & MECHANICALDRAWINGS FOR ADDITIONAL DETAILS.
NOTE! SEE ARCHITECTURAL & MECHANICALDRAWINGS FOR ADDITIONAL DETAILS.
12-GA HEAVY DUTY
WALK-IN FLOOR DETAILSCALE: 1-1/2"=1'-0"
BUILDING CONDITIONS & VENTILATION NOTES:BUILDING CONDITIONS & VENTILATION SYMBOLS
KITCHEN
FRONT SECTION
WALK-IN CLOSURE PANEL DETAILSCALE: 1-1/2"=1'-0"
COOLER/FREEZERDOOR SECTION WALL SECTION
KITCHEN COOLERCOOLER KITCHEN
ROOF CURB DETAILSCALE: 1-1/2"=1'-0"ENCLOSURE DETAIL
SCALE: 1-1/2"=1'-0"
PIPE PENETRATION
SIDE VIEW
1. ALL WORK INDICATED ON THIS PLAN AND IN THESE NOTES SHALL BE BY OTHER THAN
3. PARTITION WALLS BETWEEN KITCHEN AREAS AND PUBLIC AREAS SHALL BE CONTRUCTED FOR
2. WALLS, FLOORS AND CEILINGS IN KITCHEN, PREP, SERVICE, AND DISHWASHING AREAS, OR
THE KITCHEN EQUIPMENT CONTRACTOR, UNLESS NOTED "BY K.E.C."
ANY OTHER LOCATION WHERE FOOD OR BEVERAGES ARE PREPARED, SHALL BE SMOOTH, EASILY-CLEANABLE, NON-ABSORBANT, AND DURABLE. WALLS AND CEILINGS SHALL BE LIGHT COLORED.
H. PROVIDE FIRE-RATED PARTITIONS WHERE NOTED AROUND COOKING/HEAT PRODUCING
F. PROVIDE SOLID MASONRY CURBS WITH TROWEL-SMOOTH AND LEVEL FINISH.
B. SLOPE FLOOR TO FLOOR SINKS, FLOOR DRAINS, OR FLOOR TROUGHS.
A. PROVIDE IN-WALL REINFORCING OR BACKING, AS REQUIRED, FOR WALL-MOUNTED
K. PROVIDE 1/2" DIAMETER (MINIMUM) HANGER RODS FROM STRUCTURE ABOVE CEILING AS
J. PROVIDE COVED-BASE MOLDING OR COVED INTEGRAL FLOOR MATERIALS AS REQUIRED AT ALL
G. PROVIDE FIRE-RATED MATERIALS AND/OR INSULATION AS REQUIRED FOR EXHAUST DUCTS,
E. FILL EXCESS DEPRESSIONS AROUND WALK-IN COOLER/FREEZER WITH GROUT, FINISH FLOOR
D. PROVIDE WALK-IN COOLER/FREEZER DEPRESSIONS, SMOOTH AND TRANSIT-LEVEL, WHERE
C. PROVIDE DOOR/WALL OPENINGS AND/OR PASSAGES TO ASSURE ACCESS FOR ALL KITCHEN
C. OFFICES: 4 AIR CHANGES PER HOUR. (RECOMMEND AIR CONDITIONING).
A. KITCHEN, SERVICE, PREP AND DISHWASHING AREAS: 4 TO 6 AIR CHANGES PER HOUR.
F. VERIFY VENTILATION REQUIREMENTS SHOWN ARE IN COMPLIANCE WITH LOCAL CODES.
D. REFRIGERATION CONDENSING UNITS: 750 C.F.M. PER H.P., SUPPLY AND EXHAUST.
5. FINAL DUCT CONNECTIONS SHALL BE BY MECHANICAL CONTRACTOR, OR EQUIVALENT, UNLESS
6. FLOOR LOADING CAPACITY SHALL BE A MINIMUM OF 100 LBS. PER SQUARE FOOT OR AS
VENT STACKS, ROOF/WALL PENETRATIONS, ETC. PER LOCAL CODES.
EQUIPMENT. COORDINATE OPENING REQUIREMENTS WITH K.E.C.
MATERIAL, AND COVED BASE, AFTER COOLER/FREEZER IS INSTALLED BY K.E.C.
REQUIRED FOR VENTILATORS AND CEILING-MOUNTED EQUIPMENT, WHERE NOTED.
EQUIPMENT PER LOCAL CODES.
VERTICAL SURFACES OF KITCHEN FLOORS.
7. GENERAL CONTRACTOR (G.C.), OR EQUIVALENT SHALL:
DEPRESSIONS ARE REQUIRED. DEPTH AS NOTED.
EQUIPMENT; COORDINATE WITH K.E.C.
4. MINIMUM VENTILATION REQUIREMENTS:
REQUIRED BY LOCAL CODES.
B. STOREROOMS: 2 TO 3 AIR CHANGES PER HOUR.
E. OTHER AREAS: AS REQUIRED BY CODES OR AS NOTED.
NOTED.
MAXIMUM SOUND CONTROL.
NON-COMBUSTIBLE WALL MATERIAL
FINISHED WALL OPENING
FLOOR DEPRESSION
WALL BACKING
EXHAUST DUCT/GRILL
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
6" FLOOR DEPRESSION FORWALK-IN COOLER/FREEZERSEE NOTES 7D. & 7E. ANDDETAILS THIS SHEET.
CLOSURE PANELS FROM TOPOF WALK-IN UP TO FINISHEDCEILING BY K.E.C.
BULKHEAD ABOVE W/BOTTOM @ 7'-4" A.F.F.
BULKHEAD ABOVE W/BOTTOM @ 7'-4" A.F.F.
PROVIDE SUPPORT FROMSTRUCTURE ABOVE FOR
395-LB. HOOD. SEE NOTE 7K.
1
CLR.149-LB.
FRZ.281-LB.
PENETRATION THRU ROOF FORELECTRICAL & REFRIGERANTLINES. SEE DETAILS THIS SHEET.
3' - 0"
2' - 7
"3'
- 0"
3' - 6"
16' - 8"
10' -
0"
12" HIGH RAISED ROOF CURBS FORCOOLER/FREEZER COMPRESSORS.SEE MECH'L. SHEET NO. M-1.3 ROOFPLAN FOR EXACT LOCATION &DETAIL BELOW.36" (MIN.)CLEARANCE ON ALL SIDES.
3' - 6
"
6' - 5"
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
KITCHEN EQUIPMENT PLANSCALE: 1/4"=1'-0"
123456789101112131415161718
1172
0 Be
ltsvi
lle D
rive
Suite
600
Cal
verto
n, M
D 2
0705
Tel:
301.
595.
1000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rimm
andp
arke
r.com
K102
BUILD
ING
COND
ITION
S &
VENT
ILATIO
N PL
AN
LANSDO
WNE E
LEMENT
ARY SC
HOOL
2301 A
LMA RO
AD, BA
LTIMO
RE, MD
11/17/16BID SET
GP #21541
VENTILATION DETAILSNO. SIZE
C.F.M.TOTAL C.F.M.
W.G.S.P.@COLLAR
CONN.HGT.A.F.F. DESCRIPTIONEXHAUST SUPPLY
1 11" x 11" 750 750 -0.079 9' - 6"
SEE SHEET K501 FOR FURTHER EXHAUST CANOPY DETAILS.
DATE DESCRIPTION
12"
"P" TRAPPROVIDE AIRGAP BETWEENDRAIN & DRAINLINE.
ALL DRAIN LINES REQUIRE AMINIMUM OF 1" FALL PER FT.
NOTE: RUN EACH DRAINSEPARATELY
OPEN SITE DRAINTO STORM WATER
PIPING & INSULATION TO BEFURNISHED & INSTALLEDBY K.E.C.
(LOW TEMPERATURE ONLY)ELECTRIC HEATER SPIRALED ANDTAPED ON FREEZER DRAIN LINEBY K.E.C.
SLOPE
ACCESSPANEL
S/S HINGED
PIPING TO NEARESTFLOOR SINK BY P.C.
FLOORSINK
HOT WATERINLET BY P.C.
WAT
ER IN
HOT WATERINLET BY P.C.
HOT FOODWELL
PIPE EACH DRAININDEPENDENTLY
PULL-OUTFILL FAUCET
BY P.C.
NO SCALE NTSEVAPORATOR COIL DRAIN DETAIL DRAIN VALVE DETAIL
PLUMBING NOTES:
PLUMBING SYMBOLS
1. ALL OUTLETS AND CONNECTIONS SHOWN RELATE TO FOODSERVICE FIXTURES AND EQUIPMENT ONLY.SEE ARCHITECTURAL/ENGINEERING PLANS FOR ADDITIONAL PLUMBING REQUIREMENTS.
2. THIS PLUMBING PLAN IS INTENDED TO SHOW ROUGH-IN LOCATIONS AND HEIGHTS, CONNECTIONSIZES, POSITIONS, HEIGHTS AND LOAD REQUIREMENTS. DIMENSIONS SHOWN ARE FROM FINISHEDFLOORS AND FINISHED WALLS. VERIFY WALL PARTITION LOCATIONS WITH ARCHITECTURAL DRAWINGS.
3. FINAL CONNECTIONS TO ALL EQUIPMENT SHALL BE BY PLUMBING CONTRACTOR INCLUDING REQUIREDMATERIALS SUCH AS, STOPS, MIXING VALVES, FILTERS, TRAPS, CHECK VALVES, PIPING, TUBING, ETC. TOASSURE PROPER OPERATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODES.
4. PLUMBING CONTRACTOR (P.C.), OR EQUIVALENT, SHALL FURNISH AND INSTALL THE FOLLOWING:A. ALL WATER AND WASTE TO POINT OF ROUGH-IN AS SHOWN ON PLAN.
ROUGH-IN OUTLETS TO STUB 4" OUT OF WALLS AT HEIGHT INDICATED FROM FINISHED FLOORTO CENTERLINE OF OUTLET. FLOOR ROUGH-INS TO STUB UP 2" ABOVE FINISHED FLOOR ORCURBS. ALL FLOOR OPENINGS/PENETRATIONS ARE TO BE SEALED WATERTIGHT.
B. ALL FLOOR SINKS, COMPLETE WITH TOP GRATES INDICATED, AND REMOVABLE SEDIMENT BUCKETSSET FLUSH WITH FINISH FLOOR, UNLESS NOTED. SEE PLUMBING PLANS.
C. ALL WASTE LINES, DIRECT OR INDIRECT, EXCEPT AS NOTED. MINIMUM DIAMETER OF LINE SHALLBE AS INDICATED ON PLAN REGARDLESS OF CONNECTION SIZE, AND SHALL BE PITCHEDDOWNWARD. MAINTAIN DRAIN LINES AS HIGH AS POSSIBLE ABOVE FLOOR FOR SANITATION ANDAND CLEANING. ALL WASTE LINES SHALL HAVE ADEQUATE CLEAN-OUT PROVISIONS.
D. INDIRECT WASTE LINES FOR WALK-IN COOLER/FREEZER BLOWER COILS SHALL BE PITCHED1" PER FOOT OF HORIZONTAL RUN, AND TERMINATE WITH A P-TRAP OVER FLOOR SINK ORAPPROVED RECEPTOR WITH AIR BREAK AS REQUIRED BY LOCAL CODE.
F. INSTALL VACUUM BREAKERS WHERE SHOWN; SEE PLUMBING PLANS.
6. ALL VENT PIPES SHALL BE CONCEALED IN WALLS OR COLUMN CHASES. USE LOOP VENTS FORISLAND FIXTURES.
7. ALL EXPOSED PIPING AND FITTINGS IN KITCHEN AREAS SHALL BE CHROME-PLATED OR STAINLESSSTEEL.
8. ALL LINES ROUTED THROUGH EQUIPMENT SHALL NOT INTERFERE WITH INTENDED USE OF, ORSERVICING OF, EQUIPMENT.
HOT/COLD WATERROUGH-IN AND CONNECTION
2"
H/CW
W
IW
F.S.
F.D.
ROUGH-IN AND CONNECTIONWASTE
INDIRECT WASTE
(W/MIN. CONN. SIZE)FLOOR SINK W/HALF GRATE
FLOOR (AREA) DRAIN
ABBREVIATION SYMBOL DESCRIPTION
D.F.A. DOWN FROM ABOVE
O.S.D. OPEN SITE DRAIN (STORM WATER)
E. GREASE INTERCEPTOR LOCATED OUTSIDE; SEE PLUMBING PLANS.
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
1
2
3 3
4
55
67
6
7
6
7
89
10
10
111111
1313131313
12
14
1313131313
12
14
AREAF.D.
AREAF.D.
AREAF.D.
O.S.D. O.S.D.
AREAF.D.
DRAIN LINE TO PENETRATE THRUWALL @ 12" A.F.F. & TERMINATEOVER F.D. W/P-TRAP BY K.E.C.(TYP.)
4"F.S.
4"F.S.
4"F.S.
4"F.S.
3' - 7" 4' - 5" 1' - 11" 8' - 4"
1' - 0
"3'
- 11"
6' - 6
"8'
- 5"
9' - 2
"6'
- 6"
0' - 10" 5' - 6"
0' - 10" 5' - 6"
2' - 9"
1' - 2
"
6' - 5" 8' - 5" 7' - 2"
7' - 6
"1'
- 8"
0' - 8" 0' - 9"
1' - 9
"2'
- 3"
1' - 2
"0'
- 10"
0' - 8
"
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
0' - 8
"1'
- 4"
0' - 8
"7'
- 9"
1' - 7
"
KITCHEN EQUIPMENT PLANSCALE: 1/4"=1'-0"
123456789101112131415161718
1172
0 Be
ltsvi
lle D
rive
Suite
600
Cal
verto
n, M
D 2
0705
Tel:
301.
595.
1000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rimm
andp
arke
r.com
K103
PLUM
BING
ROU
GH-IN
PLA
N
LANSDO
WNE E
LEMENT
ARY SC
HOOL
2301 A
LMA RO
AD, BA
LTIMO
RE, MD
11/17/16BID SET
GP #21541
PLUMBING SCHEDULER.I. #
WATER WASTE R.I. HGT.A.F.F.
GPH @140 F.
CONN.DESCRIPTION EQ. #HW CW DIR IND SIZE HEIGHT.
1 3/4" 3/4" 36" 1/2" 3' - 0" MOP SINK FAUCET 32 4" STUB 4" 3" MOP SINK DRAIN 33 3/4" 5/8" 7' - 0" BLOWER COIL 44 1/2" 1/2" 15" 1/2" 3' - 4" PREP SINK FAUCET 125 2" 2" 1' - 10" PREP SINK DRAIN (2) 126 1/2" 1/2" 26" 1/2" 3' - 4" HAND SINK FAUCET 137 1 1/2" 24" 1 1/2" 2' - 4" HAND SINK DRAIN 138 1/2" 1/2" 26" 1/2" 3' - 4" EYE WASH SINK FAUCET (TEPID WATER) 159 1 1/2" 24" 1 1/2" 2' - 4" EYE WASH SINK DRAIN 1510 3/4" 3/4" 18" 3/4" 3' - 4" POT WASHING SINK FAUCET (2) 1911 2" 24" 2" 2' - 4" POT WASHING SINK DRAIN (3) 1912 1/2" STUB 1/2" 2' - 8" FILL FAUCET 31A13 3/4"(5) 3/4" 6" HOT FOOD DRAIN (5) 31A14 3/4" 3/4" 6" FROST TOP COUNTER DRAIN 31B
K.E.C. TO PROVIDE HCW TEMPERING DEVICE; PLUMBING CONTRACTOR TO INSTALL IN EQUIPMENT.(1)
(2)
(1)
DATE DESCRIPTION
SEE DRAIN VALVE DETAIL THIS SHEET.(2)
JJ
J
J
J J
JJ
J
J J
J
JJJJ
J
J
JJJJ
J
J
JJ
JJ
2. ALL PENETRATIONS THRU WALK-IN ARE TO BE SEALED WITH
1. ALL CONDUIT TO BE RUN ON EXTERIOR CEILING OF WALK-IN.
FREEZER COMPARTMENT.
5. NO METAL CONDUIT INSIDE WALK-IN BOX.
4. FURNISH LOW TEMPERATURE BALLAST (-20 °F) INSIDE
FINAL CONNECTION BY ELECTRICIAN.3. LIGHT FIXTURES TO BE SHIPPED LOOSE & INSTALLED BY K.E.C.
WITH THERMAL MASTIC
WALK-IN CEILING
PLASTIC CONDUIT &FILL VOID BETWEEN
WALK-IN PANEL SLEEVE
THERMAL MASTIC BY K.E.C.
IN CONDUITSPROVIDE "SEAL OFF" BRANCH TO
OTHER LIGHTS
MASTIC AFTER RUNNING WIREWALK-IN. FILL WITH THERMALPLASTIC CONDUIT THROUGH
VAPOR PROOF LIGHTSPER SPECS.
120 V/1 POWER SUPPLY
JUNCTION BOX
BY K.E.C.
BY K.E.C.
FINISHEDFLOOR
BRANCH CIRCUITCONDUIT & WIRE
RECEPTACLE.SEE ELECTRICAL
4-1/
2"
(MAX
. HGT
.)
MATERIALS SPECS
FINISHEDFLOOR
BRANCH CIRCUITCONDUIT & WIRE
4-1/
2"
(MAX
. HGT
.)
RECEPTACLE.SEE ELECTRICALMATERIALS SPECS
ELECTRICAL SYMBOLS ELECTRICAL NOTES:
INSTALLATION DETAILWALK-IN LIGHT
SCALE: NONE
FLOOR RECEPTACLE DETAILSCALE: NONE
L.E.D. LIGHT FIXTURE
DOWN FROM ABOVE
VAPOR PROOF LIGHT FIXTURE
D.F.A.
CONDUIT STUB W/FINALCONN. TO EQUIPMENT
SWITCH (INSTALLED IN EQUIP.BY K.E.C. OR MFR.)
SWITCH
FIXTURES OR EQUIPMENT. ALL OUTLETS, JUNCTION BOXES, COVER PLATES, ETC. IN DISHROOMS
U.L. APPROVED FOR MANUFACTURED AND FABRICATED EQUIPMENT.
FOODSERVICE EQUIPMENT BENEATH HOODS/VENTILATORS AS REQUIRED BY N.F.P.A.-96, LATEST
7. ELECTRICAL CONTRACTOR (E.C.), OR EQUIVALENT, SHALL FURNISH AND INSTALL THE FOLLOWING:A. ALL JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, ETC. NOT BUILT INTO
B. ALL PLUGS AND CORDS AS NOTED ON SCHEDULE. ALL CORDS SHALL BE N.E.M.A. RATED AND
C. SHUNT-TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE CONTROL SYSTEM SHUT-OFF OF
8. WHEN APPLICABLE, ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING, INSTALLELECTRICAL COMPONENTS (PROVIDED BY K.E.C.), AND INTERWIRE BETWEEN THE FOLLOWING:
B. WALK-IN COOLER/FREEZER LIGHTS (RUN CONDUIT ABOVE COMPARTMENT CEILING).
C. REMOTE WALK-IN COOLER/FREEZER ALARM SYSTEMS (WHEN USED).
D. CONTROL PANELS TO WATER-TYPE VENTILATORS AND EXHAUST/SUPPLY FANS PER
E. KITCHEN EXHAUST HOODS/VENTILATORS TO FIRE CONTROL SYSTEM AND SHUT-OFFS.
MANUFACTURER'S INSTRUCTIONS.
A. REMOTE REFRIGERATION SYSTEMS TO EVAPORATOR COILS.
EDITION, AND LOCAL CODES.
OR AS INDICATED ON SCHEDULE SHALL BE MOISTURE-PROOF.
D. DISCONNECTS OR OTHER DEVICES AS REQUIRED BY CODES.
POWER OUTLET, 1 PHASE
JUNCTION BOX W/FINALCONN. TO EQUIPMENT
EQUIPMENT BY K.E.C. OR MFR.)DUPLEX CONVENIENCE OUTLET
(INSTALLED IN EQUIP. BY K.E.C. OR MFR.)DUPLEX CONVENIENCE OUTLET
JUNCTION BOX (INSTALLED IN
THAT THERE IS A MINIMUM OF 3/4 INCH SPACE BETWEEN IT AND THE WALL.6. PIPING, CONDUIT, AND SIMILAR CONSTRUCTION, LOCATED OUTSIDE A WALL, MUST BE INSTALLED SO
1. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208 VOLT, 3-PH; 480 VOLT, 3-PH, 4-WIRE, 60 HERTZ.
2. ALL OUTLETS AND CONNECTIONS SHOWN RELATE TO FOODSERVICE FIXTURES AND EQUIPMENTONLY. SEE ARCHITECTURAL/ENGINEERING PLANS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.
3. THIS ELECTRICAL PLAN IS INTENDED TO SHOW ROUGH-IN OUTLET TYPES, HEIGHTS AND LOCATIONS,AND CONNECTION POSITIONS AND LOAD REQUIREMENTS. ALL DIMENSIONS SHOWN ARE FROMFINISHED WALLS AND FINISHED FLOORS. VERIFY FINISH WALL PARTITION LOCATIONS WITH
4. ALL ELECTRICAL WORK FOR FABRICATED FOODSERVICE EQUIPMENT SHALL BE COMPLETELY WIREDBY THE FABRICATION CONTRACTOR TO A COMMON JUNCTION BOX, PULL BOX, OR CONTROL PANELON THE EQUIPMENT IN AN ACCESSIBLE POSITION. FINAL CONNECTIONS TO EQUIPMENT JUNCTIONBOX OR PULL BOX, AND ALL ELECTRICAL WORK FROM MAIN PANEL BOARDS SHALL BE BY THE
5. FINAL CONNECTIONS TO ALL FOODSERVICE EQUIPMENT SHALL BE PERFORMED BY THE ELECTRICAL
CONTRACTOR, INCLUDING MATERIALS.
ELECTRICAL CONTRACTOR.
ARCHITECTURAL DRAWINGS.
V
V
S
J
J
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
1
6
8
79
3 2a.c.
b.
b.
a.
b.
b.
4
10
11
12
13
14
15
15
16
16
17
17
18
19
5 5
HEAT TAPE APPLIED TOFRZR.COIL DRAIN LINE
WHERE EXPOSED BY E.C.
RUN ALL CONDUIT ABOVEWALK-IN CLG. SEE LIGHTFIXTURE DETAIL BELOW.
WIRING FROM HI-TEMP ALARMTO BLDG. MONITORING
SYSTEM BY E.C.1" DIA. OPEN RIGID CONDUIT IN FLOOR.
STUB-UP 4" A.F.F. @ CASHIER & EXTENDTO MGR. OFFICE BY E.C.
WIRING IN CEILING FROMSWITCH TO HOOD J.B. BY
E.C.
208V/3PH WIRING FROMFAN SW. ON BLDG. WALL
TO EXH. FAN ON ROOF BYE.C.
EXTEND CONDUIT UP THRUPITCH POCKET IN ROOF
CURB.
1" DIA. OPEN RIGID CONDUIT DOWN INWALL & OUT @ 12" A.F.F. BY E.C..CAT 5 CABLE TO MGR. OFFICE. BY
K.E.C.
1" DIA. OPEN RIGID CONDUITDOWN IN WALL & OUT @ 12"
A.F.F. BY E.C. FOR CAT 5CABLE FOR TEMP.
MONITORING.
2' - 2
"
6' - 7
"1'
- 4"
1' - 6"
20
a.
b.
c.
d.
a.
b.
c.
d.
20
5' - 5"
8' - 5
"
5' - 5"
9' - 3
"
1' - 3
"1'
- 8"
21
212121
2' - 1
1"4'
- 2"
0' - 1
1"1'
- 4"
2' - 6
"
6.2
S
R
P.8
N
52 4.13.9
N.1
N.2
e.
7' - 4
"6'
- 2"
2' - 6
"
KITCHEN EQUIPMENT PLANSCALE: 1/4"=1'-0"
123456789101112131415161718
1172
0 Be
ltsvi
lle D
rive
Suite
600
Cal
verto
n, M
D 2
0705
Tel:
301.
595.
1000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rimm
andp
arke
r.com
K104
ELEC
TRIC
AL R
OUGH
-IN P
LAN
LANSDO
WNE E
LEMENT
ARY SC
HOOL
2301 A
LMA RO
AD, BA
LTIMO
RE, MD
11/17/16BID SET
GP #21541
ELECTRICAL SCHEDULE
R.I.# HP KW AMP VOLT PHR.I. HGT.
A.F.F. DESCRIPTION
E.C. TO PROVIDE
E.Q.NO.
CORD&
PLUG RECEP. DISC. J.B.
1 1/2 120 1 114" FLY FAN RECEP. 1 02 114" BRANCH TO: 02a .150 120 1 DOOR LIGHT, HEATER, ALARM 42b 32W(2) 120 1 LIGHT FIXTURE (2) 43 114" BRANCH TO: 03a .150 120 1 DOOR LIGHT, HEATER, ALARM 43b 32W(2) 120 1 LIGHT FIXTURE (2) 43c .100 120 1 HEATED RELIEF PORT 44 .150 120 1 DRAIN LINE HEAT TAPE RECEP. 4 0 05 2.4 120 1 114" AIR-SCREEN DOOR RECEP. 4 06 7.3 208 1 STUB COOLER COMPRESSOR RACK 5 07 2.3 120 1 114" COOLER BLOWER COIL 5 08 12.6 208 3 STUB FREEZER COMPRESSOR RACK 6 09 10.3 208 1 114" FREEZER BLOWER COIL 6 010 6.4 120 1 72" BULK MILK COOLER RECEP. 21 011 11.0(2) 208 3 18"/36" CONVECTION OVEN (2) 23 012 36W 120 1 114" EXHAUST CANOPY LIGHT 24 013 48" EXHAUST CANOPY LIGHT SWITCH 24 014 48" EXHAUST CANOPY FAN SWITCH 24 015 12.0 120 1 78" HEATED TRANSPORT CABINET RECEP. 25 016 9.8 120 1 94" PASS-THRU REFRIGERATOR RECEP. 26 017 6.3 208 1 94" PASS-THRU WARMING CABINET RECEP. 27 0 018 4.5 120 1 50" ICE CREAM CABINET RECEP. 28 019 4.2 120 1 50" MILK COOLER RECEP. 29 020 120/208 1 STUB SUB-PANEL TO BRANCH TO; 0
20a. 40.0 120/208 1 HOT FOOD COUNTER RECEP. 31A 020b. 8.0 120 1 FROST TOP COUNTER RECEP. 31B 020c. 2.7 120 1 ICE CREAM MERCHANDISER RECEP. 32 020d. 15.0 (Cir.) 120 1 CASH REGISTER RECEP. (DEDICATED
CIRCUIT)33 0
20e. 4.2 120 1 MILK COOLER RECEP. 30 021 9.8 120 1 94" PASS-THRU REFRIGERATOR RECEP. 26 0
SEE SHEET MECH'L. ROOF PLAN SHEET M-1.3 FOR EXACT LOCATION. ITEM FURNISHED W/MAIN-FUSED DISCONNECT SWITCH.
SEE FLOOR RECEPTACLE DETAIL THIS SHEET.
(1)
(2)
(1)
(1)
(2)
DATE DESCRIPTION
HOOD AND LIGHT SWITCHESWALLMOUNTED BY EC
ETL LISTED #3054804-001
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
NFPA #96NSF
BUILT
WITHNFPA
ACCORDANCE
No. 96
STING L
N N A R B O
A
R
IN
RATORY
.
OAB
IC, M
H
ETN
SF
1/2" DIA. ALL THREAD RODCONNECTED TO ROOF JOISTTHROUGH ANOTHER HANGING
HANGING ANGLE IS PRE-PUNCHED AT FACTORYROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR*
ANGLE
1/2" DIA. HEAVY DUTY NUTONE ABOVE AND ONE BELOWHANGING ANGLE
LED LIGHTS BY KEC.BULBS MUST BE RATED FOR5000K COLOR TEMP.
PLAN VIEW - Hood #15' 0.00" LONG 6630VHB
LED Light
11"
33"
66"
30"30"
5' 0.00"Nom./5' 0.00"OD
11"
EXHAUST RISER
HANGING ANGLE
LED LIGHT, F25T8, 25 WATTS,T-8 BALLAST
EQUIPMENTBY KEC
SECTION VIEW - MODEL 6630VHB
HOOD ACCESSORIES
1 FIELD WRAPPER 18.00" High Front, Left, Right, See detail below.
BACKSPLASH 80.00" High X 60.00" Long 304 SS
ACCESSORIES
HOOD INFORMATION
16630
VHB
5' 0.00"700 Deg. 750
11" 11" 750 -0.079" 304 SS
100%ALONE ALONE
1 FAN1
LIGHT
MODEL LENGTHMAX.
COOKINGTEMP.
EXHAUST PLENUM
TOTALEXH. CFM
RISER(S)
WIDTH LENG. DIA. CFM S.P.
HOODCONSTRUCTION
HOOD CONFIG.
END TOEND ROW
SWITCHES
QUANTITY LOCATION
HOOD INFORMATION
1 1 L.E.D. Light NO NO 294 LBS
HOODNO.
FILTER(S)
TYPE QTY. HEIGHT LENGTH
LIGHT(S)
QTY. TYPE WIREGUARD
UTILITY CABINET(S)
LOCATIONFIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRESYSTEMPIPING
HOODHANGING
WGHT
30" NOM.
80" AFF TYP.
66"
4"
ET DL IS ET DL IS
RR
ND-2 HANGING ANGLE DETAIL
HOODNO.
HOODNO.
CLOSURE PANEL DETAILS
123456789101112131415161718
1172
0 Be
ltsvi
lle D
rive
Suite
600
Cal
verto
n, M
D 2
0705
Tel:
301.
595.
1000
123456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
A
B
C
D
E
F
G
H
J
K
L
M
© GRIMM AND PARKER, P.C. 2014
© GRIMM AND PARKER, P.C. 2014
ww
w.g
rimm
andp
arke
r.com
K501
EXHA
UST C
ANOP
Y DE
TAILS
LANSDO
WNE E
LEMENT
ARY SC
HOOL
2301 A
LMA RO
AD, BA
LTIMO
RE, MD
11/17/16BID SET
GP #21541
DATE DESCRIPTION