St. Elizabeth Fire Protection System

100% Fire Sprinkler Coverage 100% Heat/Smoke Detector Coverage

Course Objectives Familiarization of system Locations of:

HydrantsFDCKnox BoxFACPSprinkler Riser RoomLiquid Oxygen

Unique Fire Protection Element Smoke Curtain Kitchen Hood System Standpipe Pre Action & VESDA Systems

Hospital GroundsNORTHAmbulance Entrance

Main Entrance

Sprinkler Riser Room

Fire Dept. Connection

Knox Box

Enunciator Panel

Standpipe

Roof Acess

Fire Department ConnectionLocated on Jensen St. Side Of Hospital

You will need the knox key to

remove the caps on the FDC

To access Key use door code followed by

#

Knox Box

Fire Alarm Control Panels

FACP located on floor one

in boiler room.

Annunciator panels

located on all floors.

Printer located near FACP prints

all activity associated with

fire systems

BRAIN(Fire Pump Control Panel)

HEART(FIRE PUMP)

CPR

Blood Vessels(Piping)

Nervous System

Sprinkler Riser Room

Water In

Pump Bypass Always Open

Fire Pump

Jockey Pump

Test Header Always Closed

Back To Riser

Double Check Valve

Floor 1 Riser/Standpip

e

Floor 2,3 & Roof

Riser/Standpipe

Standpipe

Isolation Valve Will Turn off

water to floors 2 & 3

Isolation Valve Isolates

2nd floor Sprinklers

Flow Switch Floor 2

2 ½ Inch Connection

StandpipeNorth Stairwell

2 ½ “ Connection

Both Are Supplied From Sprinkler

System

Roof Top

Roof Access South

Stairwell

RoofStandpip

e

PIV

PIV

Dry Beyond Valve

Ceiling of south Stairwell

Roof Standpipe

Kitchen Hood SystemKitchen Hood Flow Switch Is Tied Into The Fire Alarm System

Fire Curtain Separation

Located outside every elevator door. Curtains are activated with fire

alarm or sprinkler water flow

Located near stairway/ atrium on floor one.

Activated with fire alarm or water flow. In place to

prevent smoke migration between

floors.

Generator

Generator Located Here

Underground Fuel Storage

Underground tank contains approximately 3,000 gallons of

diesel fuel.

Liquid Oxygen Tank

Pre-Action System & VESDA System

Pre Action Located In

ClosetFloor 2VESDA Located On Floor 1 in

MRI Area

Loss Of Air Pressure Plus Activation Of

Smoke Detector Required For

Water To Enter The Sprinkler

Piping

Air Compressor

SolenoidHolds Water

BackVESDA Similar To Pre Action. Goes Into Pre Alarm Notifying Staff

Well In Advance Of Actual Fire.