ELECTRIC BUS CHARGING INFRASTRUCTURE
SHEET INDEX:
VICINITY MAP :
N
PROJECT SCOPE:
PROJECT ANALYSIS:
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.
2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335
All information shown or described herein is the property
of Dorado Design & Construction, Inc. and shall not be
reused, copied or reproduced in any form without the
expressed written authorization of Dorado Design &
Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
A0.0
COVER SHEET ANDGENERAL INFORMATION
201-2002
201-2002-A00.DWG
1
AS NOTED
RMC
SPR
RMC
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL I 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
FOR NORWALK TRANSIT SYSTEM (NTS)
NOTES:
PROJECT DIRECTORY:
BUS
FUEL
STATION
WASH
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
6
6
'
-
8
"
(
D
I
S
T
A
N
C
E
B
E
T
W
E
E
N
E
X
I
S
T
I
N
G
F
U
E
L
S
T
A
T
I
O
N
A
N
D
N
E
W
E
Q
U
I
P
M
E
N
T
I
S
M
I
N
I
M
U
M
O
F
2
0
'
-
0
"
N
1.
OVERALL SITE PLAN1" = 30'
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.
2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335
All information shown or described herein is the property
of Dorado Design & Construction, Inc. and shall not be
reused, copied or reproduced in any form without the
expressed written authorization of Dorado Design &
Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
A0.1
OVERALL SITE PLAN
202-
202-A00.DWG
1
AS NOTED
RMC
SPR
RMC
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL I 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
A PLAN CHECK REVISION 02.16.21
B SCE EQUIPMENT COORDINATION 03.12.21
AREA OF WORK,REFER TO A0.1a
A
DENOTES 26'
CLR FIRE LANE
DENOTES 26'
CLR FIRE LANE
DE
NO
TE
S 26'
CLR
F
IR
E LA
NE
DE
NO
TE
S 26'
CLR
F
IR
E LA
NE
DE
NO
TE
S 26'
CLR
F
IR
E LA
NE
DE
NO
TE
S 26'
CLR
F
IR
E LA
NE
14' O
VE
RH
EA
D
CLE
AR
AN
CE
14' O
VE
RH
EA
D
CLE
AR
AN
CE
B
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
N
1.
AREA OF WORK3/16"=1'-0"
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.
2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335
All information shown or described herein is the property
of Dorado Design & Construction, Inc. and shall not be
reused, copied or reproduced in any form without the
expressed written authorization of Dorado Design &
Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
A0.1a
AREA OF WORK
202-
202-A00.DWG
1
AS NOTED
RMC
SPR
RMC
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL I 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
A PLAN CHECK REVISION 02.16.21
B SCE EQUIPMENT COORDINATION 03.12.21
OPTION "F"
A
A
B
N
1.
AREA OF WORK - CONCRETE PLAN3/16"=1'-0"
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.
2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335
All information shown or described herein is the property
of Dorado Design & Construction, Inc. and shall not be
reused, copied or reproduced in any form without the
expressed written authorization of Dorado Design &
Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
A1.1
CONCRETE PLAN
202-
202-A00.DWG
1
AS NOTED
RMC
SPR
RMC
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL I 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
B SCE EQUIPMENT COORDINATION 03.12.21
B
A
NOTES:
B
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
E
V
C
H
A
R
G
I
N
G
L
A
N
E
N
1.
AREA OF WORK - STRIPING PLAN3/16"=1'-0"
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.
2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335
All information shown or described herein is the property
of Dorado Design & Construction, Inc. and shall not be
reused, copied or reproduced in any form without the
expressed written authorization of Dorado Design &
Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
A2.1
STRIPING PLAN
202-
202-A00.DWG
1
AS NOTED
RMC
SPR
RMC
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL I 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
B SCE EQUIPMENT COORDINATION 03.12.21
SIGNING AND STRIPING NOTES:
“ ”
B
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335All information shown or described herein is the propertyof Dorado Design & Construction, Inc. and shall not bereused, copied or reproduced in any form without theexpressed written authorization of Dorado Design &Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
06-30-2021
DA
NIEL SAND
E21869
OVAL
E - 0
COVER SHEET
202-202 - E-0.DWG
1
AS NOTED
STAFF
STAFF
STAFF
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
ELECTRICAL ABBREVIATIONS
DUPLEX RECEPTACLE, 120V 15A UNO, WALL MOUNTED +15" A.F.F. UNO
1'x4' LED LIGHT FIXTURE
JUNCTION BOXJ
LIGHTING
POWER
GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE (FEED THROUGH TYPE)GFCI
CONDUIT BELOW FLOOR OR GRADE, OR IN SLAB. SIZE AS NOTED
CONDUIT CONCEALED IN WALL OR CEILING. SIZE AS NOTED
CONDUIT EXPOSED. SIZE AS NOTED
CONDUIT
G1-1
GENERAL NOTES
* NOTE *ALL OF THE SYMBOLS AND ABBREVIATIONS SHOWN ONTHIS SHEET MAY OR MAY NOT BE USED IN THIS SET OF
DRAWINGS.
PANELBOARD
DOUBLE DUPLEX RECEPTACLE, 120V 15A UNO, WALL MOUNTED +15" A.F.F. UNONEMA 5-15R CONFIGURATION.
(EXTERIOR GFCI RECEPTACLE SHALL BE INSTALLED IN WEATHERPROOF
NEMA 5-15R CONFIGURATION.
LOCKABLE BOX PER LAUSD SPECIFICATIONS)
* SCOPE OF WORK *ADDITION OF EV CHARGING DEVICES TO EXISTING EV SERVICE.
ENFORCEABLE CODES
HOMERUN TO PANEL "G1". PROVIDE #12 COPPER CONDUCTORS IN CONDUIT UNLESSINDICATED OTHERWISE.
MAGNETIC DOOR HOLDERDH
INDEX OF ELECTRICAL DRAWINGS
ELECTRICAL COVER SHEETELECTRICAL SITE PLANCHARGING STATION DETAILS AND LAYOUTCHARGING STATION CUT SHEETCHARGING STATION CUT SHEET
E-0E-1E-2E-3E-4
a3 SWITCH. SUBSCRIPT INDICATES CONTROLLING SWITCH
LEG. SUPERSCRIPT INDICATES THE FOLLOWING:2 TWO POLE3 THREE-WAY SWITCH4 FOUR-WAY SWITCHWP WEATHERPROOFD DIMMERM MANUAL MOTOR STARTERK KEY OPERATEDP PILOTLOS LINE VOLTAGE OCCUPANCY SENSOR. "a,b",
SUBSCRIPT REPRESENTS DUAL RELAY SENSORVS VACANCY SENSOR. "a,b" SUBSCRIPT
REPRESENTS DUAL RELAY SENSORLV LOW VOLTAGE TYPE, DIMMABLE
LOW VOLTAGE WALL MOUNTED OCCUPANCY SENSORWITH DIMMING
SWITCHES
DUAL TECHNOLOGY CEILING SENSOR
ROOM CONTROLLER
PHOTOCELL FOR CONTROL OF LIGHTS IN DAYLIT SPACE.PROVIDE WIRING FOR AUTOMATIC DIMMING CONTROL OFLIGHTS IN DAYLIT SPACE.
RC
PC
OS
2019 CALIFORNIA ADMINISTRATIVE CODE (CAC)PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
2019 CALIFORNIA BUILDING CODE (CBC)PART 2, TITLE 24, CCR BASED ON THE 2018 INTERNATIONAL BUILDING CODE (IBC)
2019 CALIFORNIA ELECTRICAL CODE (CEC)PART 3, TITLE 24, CCR BASED ON THE 2017 NATIONAL ELECTRICAL CODE (NEC)
2019 CALIFORNIA MECHANICAL CODE (CMC)PART 4, TITLE 24, CCR BASED ON THE 2018 UNIFORM MECHANICAL CODE (UMC)
2019 CALIFORNIA PLUMBING CODE (CPC)PART 5, TITLE 24, CCR BASED ON THE 2018 UNIFORM PLUMBING CODE (UPC)
2019 CALIFORNIA FIRE CODE (CFC)PART 9, TITLE 24, CCR BASED ON THE 2018 INTERNATIONAL FIRE CODE (IFC)
2019 CALIFORNIA GREEN BUILDING CODE (CGC)PART 11, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
1. BEFORE STARTING ANY WORK, EXAMINE THE COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, MECHANICAL,PLUMBING, LIGHTING AND A/V. VERIFY ALL DIMENSIONS, SPACE REQUIREMENTS, AND POINTS OF CONNECTION TO ALL EQUIPMENT. MAKE ANY MINOR ADJUSTMENTSNECESSARY TO AVOID CONFLICTS OF OTHER TRADES. MAJOR (REQUIRING COST ADJUSTMENTS) DISCREPANCIES SHALL BE RESOLVED IN WRITING PRIOR TOPERFORMING ANY WORK.
2. CONTRACTOR SHALL VISIT JOB SITE AND THOROUGHLY EXAMINE ALL EXISTING CONDITIONS WHICH MAY AFFECT WORK PRIOR TO SUBMITTING BID. NO ADDITIONALCOSTS WILL BE CONSIDERED FOR CONTRACTORS FAILURE TO DO SO. EXPOSED PARTS OF SWITCHBOARDS, PANELS, TRANSFORMERS, BOXES, CONDUITS, ETC. WERENOT OPENED DURING THE DESIGN PHASE OF THE PROJECT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE ENGINEER AND/OR OWNER IFINACCURACIES OR OTHER DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS ARE FOUND.
3. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT A COMPLETE AND WORKABLE ELECTRICAL INSTALLATION BE PROVIDED FOR ALL THE EQUIPMENTDESCRIBED OR SHOWN AS BEING IN THIS CONTRACT. DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND CONDUIT ROUTING IS THE RESPONSIBILITY OF THE ELECTRICALCONTRACTOR. NO SURFACE MOUNTED CONDUIT IS PERMITTED EXCEPT AS INDICATED ON DRAWINGS OR IN OPEN CEILING AREAS. EXPOSED CONDUIT SHALL BEROUTED PARALLEL AND PERPENDICULAR TO THE BUILDING STRUCTURE. PAINT EXPOSED CONDUIT. SPECIAL CARE SHALL BE TAKEN WHEN ROUTING CABLING, CABLETRAYS, CONDUITS AND WIRES WITHIN OPEN CEILING SPACES IN VIEW OF THE PUBLIC. MAINTAINING AESTHETICS ARE PARAMOUNT IN THE ROUTING AND INSTALLATIONOF EQUIPMENT. COORDINATE WITH OTHER TRADES AND ENSURE WORK IS COMPLETED IN A NEAT AND ORGANIZED MANNER.
4. FURNISH ALL LABOR AND MATERIALS NECESSARY AND FURNISH AND INSTALL ALL APPARATUS, MATERIALS, EQUIPMENT AND COMPONENTS IN A MANNER COMPLYINGWITH ALL APPLICABLE CODES, INCLUDING ITEMS REQUIRED BUT NOT NORMALLY SHOWN, SUCH AS COUPLINGS, HANGERS, BRACKETS, CLAMPS, JUNCTION BOXES,PULLBOXES, SMALL GUTTERS, CONNECTORS AND HARDWARE. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE, OR RECOGNIZED STANDARDS SHALL BEBROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND INSPECTOR OF RECORD PRIOR TO COMMENCING ANY WORK.
5. DETERMINE ROUTING OF FEEDERS AND HOMERUNS IN COOPERATION WITH OTHER TRADES TO SIMPLIFY INSTALLATION WHEREVER POSSIBLE BUT SUBJECT TOAPPROVAL OF ENGINEER FOR VISUAL AND STRUCTURAL REASONS.
6. ALL CONDUCTORS SHALL BE COPPER, TYPE THWN-2/THHN 90 DEGREE INSULATION. ALL LUGS SHALL BE 75 DEGREE RATED, MINIMUM. CONDUCTORS INSTALLED INEXPOSED CONDUITS OUTSIDE OF BUILDING OR WITHIN ROOFING MATERIAL SHALL BE TYPE XHHW (90°C).
7. USE OF FLEXIBLE CONDUIT IS NOT ALLOWED EXCEPT FOR LENGTHS UP TO 6 FEET FOR FINAL CONNECTION TO LIGHTING FIXTURES OR VIBRATING EQUIPMENT. ALLCONDUITS SHALL INCLUDE A GROUND WIRE SIZED PER CODE. CONCEALED CONDUIT SHOULD BE INSTALLED WHEREVER POSSIBLE. IF EXPOSED CONDUITS ANDBOXES ARE INSTALLED, THEY SHALL BE PAINTED TO MATCH THE SURFACES WHERE INSTALLED WHEN VISIBLE TO THE PUBLIC.
8. GREEN INSULATED COPPER GROUNDING CONDUCTOR SHALL BE INSTALLED AND CONNECTED TO EACH POWER OUTLET, ENCLOSURE, POWER DEVICE, FIXTURE, ETC.THROUGHOUT THE SITE. THE RACEWAYS SHALL NOT BE RELIED UPON FOR EQUIPMENT GROUNDING.
9. LABEL ALL RECEPTACLES, JUNCTION BOXES, PULLBOXES, DISCONNECT SWITCHES AND CONTROL DEVICES WITH THEIR SERVING PANEL AND CIRCUIT NUMBER(S).
10. PROVIDE FIRE STOPPING AT ALL CONDUIT PENETRATIONS OF CEILINGS AND WALLS AND BACK OF ELECTRICAL BOXES COMPATIBLE WITH AND TO MAINTAIN THE FIRERATING OF THE STRUCTURE. LOCATE WALL PENETRATIONS ABOVE CEILING AREAS WHERE PRESENT.
11. ELECTRICAL CONTRACTOR TO VERIFY MOUNTING HEIGHTS OF OUTLET BOXES NEAR, ON OR WITHIN CABINETWORK, SINKS, MIRRORS, COUNTERS, ETC. OUTLETSSHOWN ON PLANS ARE APPROXIMATE ONLY AND ANY IN CONFLICT WITH OTHER OBSTRUCTIONS SHALL BE RELOCATED AT NO EXPENSE TO THE OWNER.
12. PROPERLY MOUNT EQUIPMENT TO FLOOR WITH REQUIRED HARDWARE FOR SEISMICALLY RESTRAINING EQUIPMENT AGAINST SEISMIC FORCES IN ANY DIRECTION.WHERE ANCHORAGE DETAILS ARE NOT SHOWN ON DRAWINGS, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER ANDTHE INSPECTOR.
13. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE WEATHERPROOF.
14. NEW RECEPTACLES WITHIN 6' OF SINKS SHALL BE GFCI TYPE. WEATHERPROOF RECEPTACLES SHALL BE GFCI TYPE.
15. PROVIDE CONSTANT HOT CIRCUIT (AHEAD OF CONTROLS) TO ALL EMERGENCY LIGHT FIXTURES AND EXIT SIGNS. FOR CONTROLLED EMERGENCY LIGHT FIXTURES,ALSO PROVIDE EMERGENCY SHUNT RELAY WITHIN CONTROL CIRCUIT IN ORDER TO ALLOW CONTROL OF THE FIXTURE, YET TURN FIXTURE TO FULL BRIGHT UPON LOSSOF POWER.
16. ALL NECESSARY CLEARANCES SHALL BE MAINTAINED AT ELECTRICAL EQUIPMENT TO COMPLY WITH CURRENTLY ADOPTED NATIONAL ELECTRICAL CODE (WITH STATEAMENDMENTS) AND LOCAL JURISDICTION CODE.
17. ALL METALLIC OBJECTS THAT ENCLOSE ELECTRICAL CONDUCTORS OR THAT MIGHT BE ENERGIZED BY ELECTRICAL CURRENTS MUST BE EFFECTIVELY GROUNDED.BOND ALL METAL EQUIPMENT PARTS SUCH AS ENCLOSURES, RACEWAYS, BUILDING METAL STRUCTURE, WATER PIPING, GAS PIPING AND ANY OTHER EQUIPMENTLIKELY TO BECOME ENERGIZED. SHORT SECTIONS OF METAL ENCLOSURES OR RACEWAYS USED TO PROVIDE SUPPORT OR PROTECTION OF LOW VOLTAGE (LESSTHAN 70V) CABLE ASSEMBLIES FROM PHYSICAL DAMAGE SHALL NOT BE REQUIRED TO BE GROUNDED. PROVIDE GROUND CONTINUITY AS REQUIRED BY CURRENTAPPLICABLE CODES.
18. SECTIONS WITHIN SWITCHBOARDS SHALL BE DEDICATED FOR BRANCH CIRCUIT AND FEEDER WIRING WITHIN THAT SECTION. NO SECTION WITHIN SWITCHBOARD SHALLBE USED AS A PULLBOX, JUNCTION BOX, OR THROUGH-WIRING PATHWAY FOR CIRCUITS OR SYSTEMS NOT FROM THAT SECTION.
19. TAPS TO PANEL BOARDS SHALL BE IN CONFORMANCE TO THE LISTING OF THE PANEL. THE EQUIPMENT USED TO MAKE THE TAP SHALL BE OF THE SAMEMANUFACTURER OF THE PANEL BOARD.
20. PENETRATIONS INTO FIRE RATED ASSEMBLY SHALL NOT BE LARGER THAN 4" NOMINAL ROUND OR 16 SQUARE INCHES IN OVERALL CROSS SECTION AREA WITH ANAGGREGATE AREA NOT MORE THAN 100 SQUARE FEET. (UBC SECTION 709.7).
21. ONLY WIRING METHODS CONSISTING OF TYPE MI CABLE, TYPE MC CABLE EMPLOYING A SMOOTH OR CORRUGATED IMPERVIOUS METAL SHEATH WITHOUT AN OVERALLNONMETALLIC COVERING, ELECTRICAL METALLIC TUBING, FLEXIBLE METALLIC TUBING, INTERMEDIATE METAL CONDUIT, OR RIGID METAL CONDUIT IS PERMITTED.FLEXIBLE METAL CONDUIT AND LIQUID TIGHT FLEXIBLE METAL CONDUIT SHALL BE PERMITTED, IN LENGTHS NOT TO EXCEED 4 FEET, TO CONNECT PHYSICALLYADJUSTABLE EQUIPMENT AND DEVICES THAT ARE PERMITTED IN THE PLENUM.
22. ALL ELECTRICAL WORK, MATERIALS, PRODUCTS, DEVICES, OR FIXTURES INCLUDED IN THESE CONSTRUCTION DOCUMENTS MUST BE NEW AND MUST MEET OR EXCEEDTHE REQUIREMENTS OF CALIFORNIA ELECTRICAL CODE (CEC), AMERICAN NATIONAL STANDARD INSTITUTE (ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICSENGINEERS (IEEE), NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION (NEMA), CALIFORNIA ADMINISTRATIVE CODE: TITLE 24, CITY, ADOPTED ELECTRICALORDINANCE.
23. MATERIALS AND ELECTRICAL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT.
24. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THEELECTRICAL EQUIPMENT.
25. WIRES, CABLES, AND INSULATIONS SHALL CONFORM TO ICEA-NEMA AND CALIFORNIA ELECTRICAL CODE STANDARDS AND SPECIFICATIONS. USE NEW WIRE ANDDELIVER TO THE JOB SITE IN COILS OR REELS. EACH COIL OR REEL SHALL HAVE A LABEL WITH THE MANUFACTURER'S NAME, TRADE, NAME OF WIRE, SIZE OF WIRE ANDUL LABEL.
26. PROVIDE AND MAINTAIN RECORD DRAWINGS ON THE JOB THAT ACCURATELY REFLECT CURRENT AS-BUILT STATUS OF THE PROJECT. PROVIDE AS-BUILT RECORDDRAWINGS IN CAD UPON COMPLETION OF PROJECT TO ARCHITECT OF RECORD.
27. ALL 120V BRANCH CIRCUITS GREATER THAN 70’ SHALL USE #10AWG. ALL 277V BRANCH CIRCUITS GREATER THAN 150’ SHALL USE #10AWG. ALL 208V BRANCH CIRCUITSGREATER THAN 125’ SHALL USE #10AWG
28. CONDUIT SIZES INDICATED ON THESE DRAWINGS ARE MINIMUM SIZES FOR INDIVIDUAL HOMERUNS. CONTRACTOR IS FREE TO COMBINE DIFFERENT HOMERUNS INSAME CONDUIT, DERATE CONDUCTORS AND RESIZE CONDUIT ACCORDING TO ELECTRICAL CODE REQUIREMENTS. CONTRACTOR TO PROVIDE MULTIPLE RUNS OFCONDUIT AT HIS EXPENSE TO REPLACE LARGER INDIVIDUAL RUNS OF CONDUIT INDICATED ON THESE DRAWINGS WHERE FIELD CONDITIONS WILL NOT ALLOW THEM TOBE INSTALLED IN THE SIZES SHOWN.
29. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF RATED WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24", REGARDLESS OF LOCATIONS SHOWN ONDRAWING. PROVIDE FIRE BACKING PUTTY AS REQUIRED.
30. ALL CONDUITS THAT DO NOT TERMINATE AT EQUIPMENT SHALL BE PROVIDED WITH PROTECTIVE BUSHINGS. A 3/32”, 200# STRENGTH POLYETHYLENE PULL LINE SHALLBE INSTALLED IN ALL EMPTY CONDUITS AND TAGGED TO SHOW TERMINAL POINTS AND PURPOSE OF CONDUIT RUN. USE 3/16”, 700# PULL ROPE FOR ALL RACEWAYS1-1/2” TRADE SIZE AND LARGER.
SMOKE FIRE DAMPERJSFD
2'x4' LED LIGHT FIXTURE
BUILDING DEPT. RE-SUBMITTAL 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
BUS
FUEL STATION
WASHEV C
HARGING LA
NE
EV CHARGING LANE
EV CHARGIN
G LANE
EV CHARGING LANE
1.OVERALL SITE PLAN1" = 30'
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335All information shown or described herein is the propertyof Dorado Design & Construction, Inc. and shall not bereused, copied or reproduced in any form without theexpressed written authorization of Dorado Design &Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
06-30-2021
DA
NIEL SAND
E21869
OVAL
E -1
OVERALL SITE PLAN
202-202 - E-0.DWG
1
AS NOTED
STAFF
STAFF
STAFF
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARMENT SUBMITTAL 01.21.21
EXISTING TRANSFORMER TOREMAIN SEC & SCE SUBS TOTAP AND PROVIDE CONDUITAND CONDUCTORS TO NEWPULL BOX
UTILITY PROVIDESECONDARIES, BYOTHERS. COORDINATESCOPE OF WORK WITHEXISTING CONDITIONS
BUILDING DEPT. RE-SUBMITTAL 02.16.21
B SCE EQUIPMENT COORDINATION 03.12.21
BUILDING DEPT. RE-SUBMITTAL II
B
03.12.21
BUSWASH
EV CHARGIN
G LANE
EV CHARGING LANE
EV CHARGIN
G LANE
EV CHARGING LANE
1.CHARGING STATION LAYOUT1" = 30'
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335All information shown or described herein is the propertyof Dorado Design & Construction, Inc. and shall not bereused, copied or reproduced in any form without theexpressed written authorization of Dorado Design &Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
06-30-2021
DA
NIEL SAND
E21869
OVAL
E -2
CHARGING STATIONLAYOUT AND DETAILS
202-202 - E-0.DWG
1
AS NOTED
STAFF
STAFF
STAFF
CITY REVIEW SUBMITTAL 12.17.20
BUIDLING DEPARTMENT SUBMITTAL 01.21.21
1
3.TYPICAL CHARGESTATION ELEVATION (TYPICAL PER PAIR OF CHARGERS))N.T.S.
2.ELECTRICAL RISER 1" = 30'
EXISTING SWITCH GEAR AND FUSEDDISCONNECT PROVIDED AND INSTALLED BY SCE ANDSCE SUB CONTRACTORS
NOTE:BARRIER POSTS FOR SWITCH GEAR ANDFUSED DISCONNECT PROVIDED ANDINSTALLED BY SCE AND SCE SUB-CONTRACTORS
BARRIER POSTS FOR CHARGING STATIONSPROVIDED AND INSTALLED BY THE CITYOF NORWALKS CONTRACTING FORCES.REFER ARCHITECTURAL DRAWINGS
100AFUSE
UTILITY PROVIDEDSECONDARIES, BYOTHERS. COORDINATESCOPE OF WORK WITHEXISTING CONDITIONS
100AFUSE
CH
ARG
EPO
INT
CH
ARG
EPO
INT
EXISTING SWITCH GEAR
UTILITY POWER, BY OTHERS
APPROXIMATE LOCATION OFSLAB CUT FOR CONDUIT ANDCONDUCTOR ROUTING.
TERMINATION OFCONDUITS BY OTHERS,ELECTRICALCONTRACTOR SHALLEXTEND AS REQUIRED TOCHARGEPOINTLOCATIONS, TYP.
GRADE
CHARGEPOINT EV CHARGERPROVIDED BY OTHERS
EXISTING 2" CONDUITPROVIDED BY OTHERS.
NOTES:
1. CONDUITS SHALL BE IN COMPLIANCE WITH NATIONALAND LOCAL CODE REQUIREMENTS
2. SCREENED WORK INDICATED IN THIS DIAGRAM SHALLBE PROVIDED BY OTHERS.
3. CONTRACTOR SHALL EXTEND EXISTING CONDUITSFORM POINT SHOWN AS INDICATED TO LOCATIONSHOWN ON 1/E-2.
4. ELEVATION IS DIAGRAMATIC IN NATURE,CONTRACTOR SHALL ADJUST FOR OBSERVEDCONDITIONS AS REQUIRED.
5. ALL DARKENED WORK SHALL BE PERFORMED UNDERTHIS PERMIT.
EC SHALL EXTEND EXISTING 2"CONDUIT FROM TERMINATIONPOINT TO CHARGEPOINTLOCATIONS - PROVIDETRACEWIRE FOR UG PVCCONDUIT.
EC SHALL INSTALL 3" AND 3/4"UNDERGROUND DC ANDCOMMUNICATIONS CONDUIT ANDCONDUCTORS AS INDICATED INCHARGEPOINT INSTALLATIONDOCUMENT, SHEET E-4 - PROVIDETRACEWIRE FOR UG PVC CONDUIT.
EXISTING FUSED DISCONNECT, BY OTHERS
EXISTING SWITCHBOARD WITHINTEGRATED METER, 100 AMP,480/277V, 3Ø, 4W, 35KAIC, NEMA 3R
100 AMP3P
100 AMP3PEXISTING FUSED
DISCONNECT, BY OTHERS
M
100 AMP3P
100 AMP3P
100 AMP3P
100 AMP3P
100 AMP3P
100 AMP3P
EVSE-1CPE-25062.5kW
80FLACHARGEPORT 1
2" U.G. PVC W/(3) #2 CU & (1) #8 CU GND(TYP ALL)
3/4" U.G. PVC(COMM) W/CAT-5e MIN TYP.3" U.G. PVC W/ (4) #3/0 CU,1000V MIN. & (1) #6 CUGND (DC) TYP.
MCCB400A3P
NOTES:
1. CONDUITS SHALL BE IN COMPLIANCE WITH NATIONALAND LOCAL CODE REQUIREMENTS
2. SCREENED WORK INDICATED IN THIS DIAGRAM SHALLBE EXISTING TO REMAIN, PROVIDED BY OTHERS.
3. CONTRACTOR SHALL EXTEND EXISTING CONDUITSFORM POINT SHOWN AS INDICATED TO LOCATIONSHOWN ON 1/E-2.
4. ELEVATION IS DIAGRAMATIC IN NATURE,CONTRACTOR SHALL ADJUST FOR OBSERVEDCONDITIONS AS REQUIRED.
5. ALL DARKENED WORK SHALL BE PERFORMED UNDERTHIS PERMIT.
EVSE-3CPE-25062.5kW
80FLACHARGEPORT 3
EVSE-2CPE-25062.5kW
80FLACHARGEPORT 2
EVSE-4CPE-25062.5kW
80FLACHARGEPORT 4
3/4" U.G. PVC W/(2) #14 CUFOR SHUNT
CHARGEPOINTE LOCATION,TYP.
EXISTING 3/4" CONDUITPROVIDED BY OTHERS.
EC SHALL EXTEND EXISTING 2" CONDUIT FROM TERMINATIONPOINT TO CHARGEPOINT LOCATIONS - PROVIDE TRACEWIREFOR UG PVC CONDUIT.
EC SHALL EXTEND EXISTING 3/4" CONDUIT FROM TERMINATIONTO CHARGEPOINT LOCATIONS - PROVIDE TRACEWIRE FOR UGPVC CONDUIT
EVSE-2
EVSE-1
EVSE-3
EVSE-4
BUILDING DEPT. RE-SUBMITTAL 02.16.21
B SCE EQUIPMENT COORDINATION 03.12.21
BUILDING DEPT. RE-SUBMITTAL II
B
03.12.21
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335All information shown or described herein is the propertyof Dorado Design & Construction, Inc. and shall not bereused, copied or reproduced in any form without theexpressed written authorization of Dorado Design &Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
06-30-2021
DA
NIEL SAND
E21869
OVAL
E -3
CHARGING STATIONCUT SHEET
REFERENCE ONLY
202-202 - E-0.DWG
1
AS NOTED
STAFF
STAFF
STAFF
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21
Sheet No.:
Title:
PROJECT NUMBER:
Drawn By: File Name:
REVISION ISSUES:No. DATE
Project Mgr.: Scale:
Checked By: LT Scale:
ISSUED FOR: DATE
1607 E. Walnut StreetPasadena, CA 91106
P: 818.557.1225
© Copyright: Dorado Design & Construction, Inc.2020 All rights reserved
DoradoDC.comMBE-SBE
F: 818.557.1335All information shown or described herein is the propertyof Dorado Design & Construction, Inc. and shall not bereused, copied or reproduced in any form without theexpressed written authorization of Dorado Design &Construction, Inc.
CHARGING STATION
12650 IMPERIAL HWYNORWALK, CA
90650
06-30-2021
DA
NIEL SAND
E21869
OVAL
E -4
CHARGING STATIONCUT SHEET
REFERENCE ONLY
202-202 - E-0.DWG
1
AS NOTED
STAFF
STAFF
STAFF
CITY REVIEW SUBMITTAL 12.17.20
BUILDING DEPARTMENT SUBMITTAL 01.21.21
BUILDING DEPT. RE-SUBMITTAL 02.16.21
BUILDING DEPT. RE-SUBMITTAL II 03.12.21