--- -7...all masonry shall be in accordance with as3700 - 2011, as4773 parts 1 & 2, and ncc - v2...
TRANSCRIPT
-
v APPROX.
CUT/ FILL LINE BOUNDARY - Source: SIX MAPS 9/6/20 ,----------------------------------f-------
1 -------- ,--- 5,000L
WATER TANK
LOT15 aka No.8 DP240969 RETAINING WALL
• 0.4m MAX. I
TIMBER STRUCTURE OVER TO BE REMOVED
BENCHMARK FFL OF EXISTING DWELLING
100.00
SEWER MAIN
\ "LAWN" Re: BASIX -7
49.27m2 I _j -----j - I
I
EXISTING DWELLING (NO CHANGES)
I
I I
I I
I
STORAGE
I I
I I
EXISTING STORAGE AREA TO BE REMOVED
I I
I I
I I
I I
I I
I I
I I
I
-- --- -----
- L_--- MOROBE PLACE
PROPOSED NEW RESIDENTIAL DWELLING FOR·
NAOMI WHITE LOT 15 aka No. 8 MOROBE PLACE ORANGE, NSW, 2800
mite SITE PLAN
APPLICATION
CONSTRUCTION CERTIFICATE
DATE
PAGE 9/6/2020
NOTES· SITE PLAN CHANGES - 23/9/20
_SAM MORGAN
SAM MORGAN PES!NS
0419 480 827 sm [email protected]
-
DIMENSION NOTES EXTERNAL WALLS- 90mm TIMBER STUD W/- HORIZONTAL CLADDING INTERNAL WALLS- 90mm TIMBER STUD (UNLESS INDICATED)
EXTERNAL DIMENSIONS ARE UNDERLINED EAVES- MEASURED FROM OUTSIDE OF EXTERNAL WALLS DOORS - ALL DOORS 2040 HIGH
--------------8.000---------------,
OPENING;s.------------h~,020,----------+-U1_Ql770 g
l+--------------7,820----------------tt
.hf.._if] 90
.4ltlfl.._kk_fl.
$1212
• 0
al
I z N tco0 a:, a -t
0 5
820
£l zl 1
t : 3 0 N PATIO 0 a» co CONC o co % 5 j
£ 0 z z
0 0 0
3 0 0 co co_ 0 • I S0606 450 EAVES
4,000 J 2,210---"-----2.300
OPENING;s.f--------3, 735-------+-! §J_QJ435
,.__-------4.78111---------+------.1R
AREA Living 57.77m2
Total 57.77m2 (6.22SQ)
CONSTRUCTION NOTES
BASIX REQUIREMENTS QUICK REFERENCE BASIX COMMITMENTS- FOR FULL DETAILS, REFER TO BASIX CERTIFICATE
CERTIFICATE NUMBER -1139407S WATER
APPLICATION RATING/ REQUIREMENTS SHOWER HEADS 4 STAR
TOLIETS 5 STAR
KITCHEN TAPS 4 STAR
BATHROOM TAPS 4 STAR
WATER TANK 5,000L
THERMAL COMFORT CONSTRUCTION R-VALUE
CONCRETE SLAB ON GROUND NIL
EXTERNAL WALL- FRAMED 2.40(2.80 INCLUDING CONSTRUCTION)
CEILING & ROOF - FLAT CEILING/ PITCHED ROOF CEILING: 4 UP - ROOF: FOIL/SARKiNG
ROOF UNVENTILATED - MEDIUM
WINDOWS SEE BASIX CERTIFICATE
ENERGY APPLICATION RATING/ REQUIREMENTS
HOT WATER GAS INSTANTANEOUS -4.5 STAR
COOLING SYSTEM 1 PHASE ELECTRIC - EER 3.0-3.5
HEATING SYSTEM 1 PHASE ELECTRIC- EER 3.0-3.5
VENTILATION SEE BASIX CERTIFICATE
ARTIFCIAL LIGHTING SEE BASIX CERTIFICATE
NATURAL LIGHTING MUST INSTALL A WINDOW IN 1 BATHROOMS/ TOILETS
COOKING GAS COOKTOP & ELECTRIC OVEN
DRYING OUTDOOR FIXED CLOTHESLINE
GENERAL All building work and construction is to comply with the relevant sections of the National Construction
Code - Class 1 & Class 10- Building Code of Australia
DIMENSIONS All dimensions are shown in millimetres (unless otherwise indicated). DO NOT SCALE from drawing
All dimensions and levels are to be confirmed on site prior to construction.
TIMBER FRAME All timber used in the building shall be strictly in accordance with the provision of AS1684 - 2010,
natural timber framing code.
STRUCTURAL ELEMENTS All structural concrete and steelwork to be designed by a qualified structural engineer.
STAIRWAYS Construction of any stairways & balustrades shall comply with the requirements of the NCC - V2-Part 3.9.1.
CONSTRUCTION OF SANITARY COMPARTMENTS Where a closet pan is within 1200mm of any part of the door frame, lift off hinges must to provided to the
door as per NCC - V2-Part 3.8.3.3 requirements.
INSULATION Wall & ceiling insulation refer to BASIX / NATHE RS certificate.
WET AREAS Water proofing of wet areas must comply with the NCC-V2 - 3.8.1 and relevant parts of AS3740.
DAMP PROOFING OF FLOORS ON THE GROUND Vapour barrier in accordance with AS2870 NCC - V2-Part 3.2.2.6 to prevent moisture reaching
the upper surface of the floor
TERMITE PROTECTION Termite risk management in accordance with AS3660. 1-2000 and NCC-V2-3.1.3 must be provided.
SMOKE ALARMS Hardwired and interlinked smoke alarms to be installed in accordance with NCC-V2-Part 3.7.2 and AS3786.
MASONRY STRUCTURE All masonry shall be in accordance with AS3700 - 2011, AS4773 Parts 1 & 2, and NCC - V2 3.3.1.
GUTTERS & DOWNPIPES All gutters and downpipes shall be in accordance with AS/NZ3500.3 & AS/NZ3500.5 and NCC - V2-3.5.2
GLAZING All glazing to comply with NCC - V2-Part 3.6 in accordance with AS2047 and AS1288
PLIABLE BUILDING MEMBRANE For climate zones 6,7 & 8, a pliable building membrane, complying with AS/NZS 4200.1, must be located on
the external side of the wall and be installed in accordance with AS4200.2
EXHAUST SYSTEMS An exhaust system installed in a bathroom, kitchen, sanitary compartment or laundry must have a minimum
flow rate of; 25L's for a bathroom or sanitary compartment and; 40L's for a kitchen or laundry. Exhaust from a bathroom, sanitary compartment or laundry must be discharged via a dust or shaft directly to
outdoor air or to a ventilated roof space in accordance with NCC - V2-3.8.7.4
ROOF SPACE VENTILATION Where an exhaust system discharges into a roof space, the roof space must be ventilated to outdoor air.
Openings required must have an unobstructed area of 1/150 for roof pitch 22°
PROPOSED NEW RESIDENTIAL DWELLING FOR
NAOMI WHITE LOT 15 aka No. 8 MOROBE PLACE ORANGE, NSW, 2800
mte FLOOR PLAN, BASIX, CONSTRUCTION NOTES
:DATE
--------------------'-------'2C../ 3
%%%aocsacs L... a SAM MORGAN
NOTES ISAM MORGAN
.-.- .
I DA~~TtSot!~ 0419 480 827
-
TILE ROOF -22.5° PITCH
CEILING HEIGHT -42440
FLOOR LEVEL ±0o
i I
I r ALUMINIUM WINDOWS SELECT CLADDING
O West Elevation SCALE 1:100
O South Elevation SCALE 1:100
O East Elevation SCALE 1:100
O North Elevation SCALE 1:100
PROPOSED NEW RESIDENTIAL DWELLING FOR
NAOMI WHITE LOT 15 aka No. 8 MOROSE PLACE ORANGE, NSW, 2800
TITLE:
ELEVATIONS
APPLICATION· CONSTRUCTION CERTIFICATE
DATE __ 9/6/2020~~~~~-T:~-~ADDED PAGE.
3/3 -TC"tr f
1:100 @A DRAWN BY
SAM MORG,
23/9/20 SAM MORGAN
r DA~~Tttiit-!;;?
0419 480 827 [email protected]