* 3-9 0 3-6 7 3-0 5 * camera control unit ccu …pdf.crse.com/manuals/3903673051.pdfcamera control...

20
CAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3 - 9 0 3 - 6 7 3 - 0 5 * The supplied CD-ROM includes operation manuals for the CA-590/590P, CCU-590/590P, and CCU-790/ 790P (English, Japanese, French, German, Italian, and Spanish versions) in PDF format. For more details, see “ Using the CD-ROM Manual” on page 6.

Upload: trinhthuan

Post on 28-Apr-2018

221 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

CAMERA CONTROL UNIT

CCU-790/790P

OPERATION MANUAL [English]

1st Edition (Revised 4)

* 3 - 9 0 3 - 6 7 3 - 0 5 *

The supplied CD-ROM includes operation manuals for the CA-590/590P, CCU-590/590P, and CCU-790/790P (English, Japanese, French, German, Italian, and Spanish versions) in PDF format. For more details, see “ Using the CD-ROM Manual” on page 6.

Page 2: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

2

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

THIS APPARATUS MUST BE EARTHED.

Afin de réduire les risques d’incendie ou d’électrocution, ne pas exposer cet appareil à la pluie ou à l’humidité.

Afin d’écarter tout risque d’électrocution, garder le coffret fermé. Ne confier l’entretien de l’appareil qu’à un personnel qualifié.

CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE.

Um die Gefahr von Bränden oder elektrischen Schlägen zu verringern, darf dieses Gerät nicht Regen oder Feuchtigkeit ausgesetzt werden.

Um einen elektrischen Schlag zu vermeiden, darf das Gehäuse nicht geöffnet werden. Überlassen Sie Wartungsarbeiten stets nur qualifiziertem Fachpersonal.

DIESES GERÄT MUSS GEERDET WERDEN.

For the customers in the U.S.A. (for CCU-790)This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

For the State of California, USA onlyPerchlorate Material - special handling may apply, Seewww.dtsc.ca.gov/hazardouswaste/perchloratePerchlorate Material : Lithium battery contains perchlorate.

For the customers in Europe (for CCU-790P)This product with the CE marking complies with both the EMC Directive and the Low Voltage Directive issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European standards: • EN60950-1 : Product Safety • EN55103-1 : Electromagnetic Interference (Emission) • EN55103-2 : Electromagnetic Susceptibility (Immunity) This product is intended for use in the following Electromagnetic Environments: E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors), E4 (controlled EMC environment, ex. TV studio)

Pour les clients européens (pour CCU-790P)Ce produit portant la marque CE est conforme à la fois à la Directive sur la compatibilité électromagnétique (EMC) et à la Directive sur les basses tensions émises par la Commission de la Communauté Européenne.La conformité à ces directives implique la conformité aux normes européennes suivantes :• EN60950-1 : Sécurité des produits• EN55103-1 : Interférences électromagnétiques (émission)• EN55103-2 : Sensibilité électromagnétique (immunité)Ce produit est prévu pour être utilisé dans les environnements électromagnétiques suivants : E1 (résidentiel), E2 (commercial et industrie légère),E3 (urbain extérieur) et E4 (environnement EMC contrôlé, ex. studio de télévision).

Für Kunden in Europa (für CCU-790P)Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die EMV-Richtlinie sowie die Niederspannungsrichtlinie der EG-Kommission. Angewandte Normen: • EN60950-1: Sicherheitsbestimmungen• EN55103-1: Elektromagnetische Verträglichkeit

(Störaussendung)

This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING

AVERTISSEMENT

WARNUNG

Page 3: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

• EN55103-2: Elektromagnetische Verträglichkeit (Störfestigkeit), für die folgenden elektromagnetischen Umgebungen: E1 (Wohnbereich), E2 (kommerzieller und in beschränktem Maße industrieller Bereich), E3 (Stadtbereich im Freien) und E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio).

For the customers in Europe (for CCU-790P)The manufacturer of this product is Sony Corporation, 1-7-1 Konan, Minato-ku, Tokyo, Japan.The Authorized Representative for EMC and product safety is Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.

Pour les clients européens (pour CCU-790P)Le fabricant de ce produit est Sony Corporation, 1-7-1 Konan, Minato-ku, Tokyo, Japon.Le représentant autorisé pour EMC et la sécurité des produits est Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Allemagne. Pour toute question concernant le service ou la garantie, veuillez consulter les adresses indiquées dans les documents de service ou de garantie séparés.

Für Kunden in Europa (für CCU-790P)Der Hersteller dieses Produkts ist Sony Corporation, 1-7-1 Konan, Minato-ku, Tokyo, Japan.Der autorisierte Repräsentant für EMV und Produktsicherheitist Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Deutschland. Bei jeglichen Angelegenheiten in Bezug auf Kundendienst oder Garantie wenden Sie sich bittean die in den separaten Kundendienst- oder Garantiedokumenten aufgeführten Anschriften.

For kundene i NorgeDette utstyret kan kobles til et IT-strømfordelingssystem.

For the customers in Taiwan only

3

Page 4: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

4 Table of Contents

Table of Contents

Overview ............................................................................... 5Using the CD-ROM Manual .................................................. 6

Preparations ...............................................................................6Reading the CD-ROM manual ..................................................6

Function and Location of Parts and Controls ................... 7Front panel ................................................................................ 7Rear panel ................................................................................. 8

Internal Parts and Internal Boards.................................... 11Internal parts ............................................................................11Internal boards .........................................................................11

Connecting the CCU-790/790P to the Video Camera ...... 12Notes on connections .............................................................. 12

Self-Diagnostics ................................................................. 13Settings of the camera..............................................................13Status display of the camera system ........................................13Self-diagnostics of the camera system.....................................13Settings of the network ............................................................14Self-diagnostics results of the CCU-790/790P internal

boards .............................................................................15Self-diagnostics results of the camera internal boards ............16ROM version indication ..........................................................17Exiting the Self-diagnostic mode.............................................17When an error occurs...............................................................17

Specifications ..................................................................... 17General.....................................................................................17Input signals.............................................................................17Output signals ..........................................................................18Camera input/output signals ....................................................18Supplied accessories ................................................................18Optional accessories ................................................................18

Page 5: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

Overview

The CCU-790/790P Camera Control Unit provides a variety of remote control and adjustment functions for the processing of signals from a BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP CCD Color Video Camera, and can be used in Electronic Field Production (EFP) or studio work. Signal control is performed with an optional MSU-900/950 Master Setup Unit or an RCP-750/751/920/921 Remote Control Panel.

The CCU-790/790P has the following features:

Wide variety of system configurations• The optional CA-905K/F/T large-lens adaptor allows a

large lens to be fitted onto the portable video camera and used in conjunction with the BVF-77/77CE 7-inch B/W Viewfinder.

• 3 output lines (composite video or SDI can be selected as the output signal) are provided.

• 3 SDI output lines are provided (available only when SDI signal output is selected for the VBS/SDI-1 connector).

• The CCU-790/790P supports communications between the video camera and the CCU-790/790P over either a triax cable or coaxial cable. (Power, however, is not supplied to the video camera in the case of coaxial cable.)

• When a video camera equipped with the AC OUT connector is connected to the CCU-790/790P, the video camera can supply power which is supplied from the CCU-790/790P to an external device through the AC OUT connector. This can be done by the setting on the video camera.

For details, refer to the Operation Manual supplied with the video camera.

10-MHz, wideband triax transmission• Wideband triax transmission with Y signal at 10 MHz,

R-Y and B-Y signals at 6 MHz is used for inputting video signals from the video camera. The triax cable length can be extended from 50 to 1,000 m (with Fujikura φ8.5 mm cables), 75 to 1,500 m (with BELDEN 9232 φ13.2 mm cables), or 100 to 2,000 m (with Fujikura φ14.5 mm cables).

• The CCU-790/790P supports teleprompter signal transmission. Teleprompter signals can be transferred over distances of 50 to 500 m (with Fujikura φ8.5 mm cables), 75 to 750 m (with BELDEN 9232 φ13.2 mm cables), or 100 to 1,000 m (with Fujikura φ14.5 mm cables).

Rack mountableThe CCU-790/790P is three-units high and can be mounted in a 19-inch EIA standard rack.

For details on the rack mounting, refer to the System Manual.

Production of some of the peripherals and related devices described in this manual has been discontinued. For advice about choosing devices, please contact your Sony dealer or a Sony sales representative.

Note

Overview 5

Page 6: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

6

Using the CD-ROM Manual

The supplied CD-ROM includes versions of the Operation Manuals for the CA-590/590P, CCU-590/590P, and CCU-790/790P1) in PDF format.

1)Available languages: Japanese (CA-590 and CCU-590 only), English, French, German, Italian, and Spanish

Preparations

The following program must be installed on your computer in order to read the operation manuals contained on the CD-ROM.• Adobe Reader Version 6.0 or higher

If Adobe Reader is not installed, you can download it from the following URL:http://www.adobe.com/

Adobe and Adobe Reader are trademarks of Adobe Systems Incorporated in the United States and/or other countries.

Reading the CD-ROM manual

To read the operation manual contained on the CD-ROM, do the following.

1 Insert the CD-ROM in your CD-ROM drive.

A cover page appears automatically in your browser.If it does not appear automatically in the browser, double-click on the index.htm file on the CD-ROM.

2 Select and click on the operation manual that you want to read.

This opens the PDF file of the operation manual.

The files may not be displayed properly, depending on the version of Adobe Reader. In such a case, install the latest version you can download from the URL mentioned in “Preparations”above.

If you have lost or damaged the CD-ROM, you can purchase a new one to replace it. Contact your Sony service representative.

Memo

Note

Using the CD-ROM Manual

Page 7: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

Function and Location of Parts and Controls

Front panel

a Red tally lampLights when the unit receives a red tally signal. When the CALL button on the video camera, MSU-900/950 Master Setup Unit, or RCP-750/751/920/921 Remote Control Panel is pressed, the lamp lights if it is not lit, or goes dark if it is lit. Attach a supplied number plate here.

For details on attaching a number plate, refer to the System Manual.

b Green tally lampLights when the unit receives a green tally signal. Attach a supplied number plate here.

For details on attaching a number plate, refer to the System Manual.

c MIC (microphone)/PGM (program audio) switchON: Turns on the headset microphone.OFF: Turns off the headset microphone.PGM: Outputs the program audio when the one ear

headset is used. When this position is selected, the INTERCOM level control adjusts input level of the program audio. The level of the PGM1 and PGM2 can be adjusted by using the VR located on the panel side of the internal AU board.

d INTERCOM level controlAdjusts the receiving level of the intercom.

e INTERCOM connector (XLR 5-pin)Connect a headset.

f CAMERA POWER switch and indicatorThis switch controls the power supply to the video camera when the MAIN POWER switch is set to the ON side (I position). The indicator lights when power is supplied to the video camera.If an RCP-750/751/920/921 Remote Control Panel is connected to this unit, the CAM PW switch on the panel must be lit for control of the power supply to the camera with this switch to be enabled.

g MAIN POWER switch and indicatorThis switch turns on and off the power supply to the entire camera system including this unit, a BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP Color Video Camera, and an RCP-750/751/920/921 Remote Control Panel connected to the REMOTE connector. The indicator lights when power is supplied to the system.

h CABLE ALARM indicatorsOPEN: Lights when no triax cable is connected to the

CAMERA connector on the rear panel of the CCU-790/790P, or when the load current is extremely low even when a camera cable is connected.

SHORT: Lights when there is a current overflow in the triax cable.

CAMERA CONTROL UNIT CCU-790

CABLEALARM MIC

INTERCOM

SHORT

MAIN

POWER POWER

CAMERA

OPEN

ONOFFPGM

b Green tally lamp

a Red tally lamp

c MIC/PGM switch

d INTERCOM level control

e INTERCOM connector

f CAMERA POWER switch and indicator

g MAIN POWER switch and indicator

h CABLE ALARM indicators

Function and Location of Parts and Controls 7

Page 8: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

8

Rear panel

a CAMERA connector (triax connector)Connects to the CA-570/570P/590/590P/905K/F/T Camera Adaptor attached to the BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP Color Video Camera using a triax cable.

Do not use a defective triaxial cable.The inner sheath of a triaxial cable is used for power supply and the outer sheath for safety ground.For your safety, do not use a triaxial cable whose inner and outer sheaths are short-circuited. Use of such a cable will cause electric shock.

b AUDIO OUTPUT connectors (XLR, 3-pin)Supply audio signals from the video camera.

c INPUT connectorsThe REFERENCE INPUT connectors, RET-1 connectors, and the RET-2/PROMPTER connectors are loop-through connectors.

A REFERENCE INPUT connectors (BNC type)The upper connector accepts reference signals (black burst signal) for external synchronization. The input signal is output from the lower connector. The reference input signal can be terminated at 75 ohms internally. To terminate the signal, input the reference signal to the upper connector.

a CAMERA connector

b AUDIO OUTPUT connectors

c INPUT connectors

d OUTPUT connectors

e REMOTE connector

f ETHERNET connector

i WF MODE connector

j AC IN connector

g INTERCOM/TALLY/PGM connector

h MIC REMOTE connector

k SDI OUTPUT connectors

Caution

A REFERENCE INPUT connectors

B RET-1 connectors

C RET-2/PROMPTER connectors

D SDI RET-3/RET-4 connectors

E COAX connector

F SPARE connector

Function and Location of Parts and Controls

Page 9: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

B RET-1 (return video signal 1) connectors (BNC type)

The upper connector accepts return video signal. The input signal is output from the lower connector.

For details on the selection of RET-1, refer to Operation Manual that came with the camera or camera adaptor.

C RET-2 (return video signal 2)/PROMPTER connectors (BNC type)

The upper connector accepts return video signal or teleprompter signal. The input signal is output from the lower connector. The signal is split and output to the RET-2 and PROMPTER signal lines.

For details on the selection of RET-2, refer to Operation Manual that came with the camera or camera adaptor.

Use the switch on the internal board to output the prompter signal.

For details on the internal boards, consult your Sony service personnel.

D SDI (serial digital interface) RET-3/4 (return video signal 3/4) connectors (BNC type)

Accept SDI return video signal. (These connectors are not loop-through connectors.)

For details on the selection of RET-3 or RET-4, refer to Operation Manual that came with the camera or camera adaptor.

E COAX (coaxial) connector (BNC type)Accepts and supplies signal from/to the video camera using a coaxial cable. Power is not supplied to the camera or a camera adaptor through this connector.

To use this connector, it is required to change the setting of the internal board. For details, consult your Sony service personnel.

F SPARE connector (BNC type)Not used.

d OUTPUT connectors

A VBS (composite video signal)/SDI (serial digital interface)-1, VBS/SDI-2, VBS/SDI-3 connectors (BNC type)

Supply the signal from the video camera in composite or SDI format.Use the switch on the internal board to select the composite video signal or SDI signal.

For details on the internal boards, consult your Sony service personnel.

B Y/G, R-Y/R, B-Y/B (component video signal/RGB output) connectors (BNC type)

Supply the component signals or the R, G, and B signals for the chroma keyer from each connector.Use the switch on the internal board to select the signals to be output.

For details on the internal boards, consult your Sony service personnel.

C PIX (picture monitor output) connector (BNC type)Supplies a video signal or video and character signals together to a picture monitor.Use the WF/PIX Select menu (in MSU-950, RCP-750/751, or RM-B750) or the PICTURE MONITOR button (on MSU-900) to select the signal output from the PIX connector. When the output signal is changed on the RCP-750/751 or the RM-B750, the waveform output on the waveform monitor also changes.

D SYNC connectorConnect to the synchronous signal input connector on a waveform monitor or picture monitor.

E WF (waveform monitor output) connector (BNC type)

Supplies a video signal to a waveform monitor.Use the WF/PIX Select menu (in MSU-950, RCP-750/751, or RM-B750) or the WAVEFORM MONITOR button

A VBS/SDI-1, VBS/SDI-2, VBS/SDI-3 connectors

B Y/G, R-Y/R, B-Y/B connectors

C PIX connector

D SYNC connector

E WF connector

Function and Location of Parts and Controls 9

Page 10: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

10

(on MSU-900) to select the signal output from the WF connector. When the output signal is changed on the RCP-750/751 or the RM-B750, the picture on the picture monior also changes.

e REMOTE (remote control) connector (8-pin)Connects to the MSU-900/950 Master Setup Unit, RCP-750/751/920/921 Series Remote Control Panel or RM-B750 Remote Control Unit with an optional CCA-5-xx connecting cable to transmit/receive control signals.

f ETHERNET connectorThrough this connector, the Ethernet system can be built with the devices conforming to 700 Protocol Over TCP/IP, such as the MSU-900/950 or RCP-920/9211), etc. In order to build the Ethernet system, the internal switch setting and the network-related settings must be made.

For details, consult your Sony service personnel.

1)Power must be supplied to the RCP-920/921 through the Ethernet connection.

For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port.

Par mesure de sécurité, ne raccordez pas le connecteur pour le câblage de périphériques pouvant avoir une tension excessive à ce port. Suivez les instructions pour ce port.

Aus Sicherheitsgründen nicht mit einem Peripheriegerät-Anschluss verbinden, der zu starke Spannung für diese Buchse haben könnte. Folgen Sie den Anweisungen für diese Buchse.

g INTERCOM/TALLY/PGM (program audio) connector (D-sub, 25-pin)

Inputs/outputs intercom, tally, or program audio signals. Connects to an intercom, tally, or program audio connector of an intercom system.

h MIC REMOTE (microphone remote control) connector (D-sub, 15-pin)

Connects to an external control unit such as an audio mixer. With the connected unit, you can set the microphone input level of the video camera to –60, –50, –40, –30, or –20 dB.

i WF MODE (waveform monitor mode) connector (4-pin)

Connects to the corresponding connector on a waveform monitor to allow the sequential monitoring of signals.

j AC IN (AC power input) connectorConnects to an AC power source using the supplied AC power cord. Secure the power cord to the CCU-790/790P using the supplied plug holder.

k SDI (serial digital interface) OUTPUT connectors

A SDI-4/5/6 connectors (BNC type)When the VBS/SDI-1 connector is set to output the SDI signal, the same signal as that to be output from the VBS/SDI-1 connector is output from these connectors.

B SPARE connector (BNC type)Not used.

CAUTION

ATTENTION

ACHTUNG

A SDI-4/5/6 connectors

B SPARE connector

Function and Location of Parts and Controls

Page 11: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

Internal Parts and Internal Boards

To reduce the risk of electric shock, fire or injury, do not open the cabinet. To adjust the internal settings or to replace the fuses, refer to qualified service personnel.

The following parts and boards are located inside the unit, behind the front panel.

Internal parts

a Headset microphone switch 1 (S52)Set the switch according to the type of microphone of the headset connected to the INTERCOM/TALLY/PGM connector on the rear panel of this unit.CARBON: Carbon microphone (power supply, 20 dB

gain)ECM: Electret condenser microphone (power supply, 40

dB gain)DYNAMIC: Dynamic microphone (no power supply, 60

dB gain) (factory-setting)

b INCOM (intercom) selectorSelects the pathway of intercom signals output/input through the INCOM/TALLY/PGM connector.PROD: Producer line.PRIV: Producer line and engineer line are cut off and

communication is possible only between the CCU-790/790P and the camera connected to the rear panel of the CCU-790/790P.

ENG: Engineer line. The settings regarding the output intercom signals can be performed on the internal AU board. For details, consult your Sony service personnel.

c Headset microphone switch 2 (S53)When the headset microphone switch 1 (S52) is set to DYNAMIC, set this switch according to the type of output of the headset microphone.GND: Unbalanced type (factory-setting)OPEN: Balanced type

d FusesWhen the fuses need to be replaced, consult your Sony service personnel.

Internal boards

For details on the internal boards, consult your Sony service personnel.

Note

CABLEALARM MIC

INTERCOM

SHORT

MAIN

POWER POWER

CAMERA

OPEN

ONOFFPGM

a Headset microphone switch 1 (S52)

b INCOM selector

d Fuses

c Headset microphone switch 2 (S53)

Internal boards

Internal Parts and Internal Boards 11

Page 12: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

12

Connecting the CCU-790/790P to the Video Camera

When connecting a CCU-790/790P to a BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP Color Video Camera, you must first attach the CA-570/570P/590/590P Camera Adaptor to the video camera.

A large lens and the BVF-77/77CE 7-inch Viewfinder are connected to the CCU-790/790P through the CA-905K/F/T series large-lens adaptor and the BKP-9057 Viewfinder Saddle, as shown in the illustration below.

Notes on connections

Triax cableThe triax cable should never be connected to or disconnected from the CCU-790/790P when the power is turned on. Always turn the unit off first.

Video cameraSome switches or controls on the video camera may not work when the camera is connected to the CCU-790/790P.

For details, refer to Operation Manuals of the video camera and the camera adaptor.

The maximum power output from the CAMERA connector of the CCU-790/790P is 360 VA (including a cable loss). Do not connect any equipment which consumes more than 360 VA of power.

Note

CA-570/570P/590/590P

BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP

Triax cable

When a large lens is used

BVF-77/77CECA-570/570P/590/590P

BVP-E10/E10P/E10WS/E10WSP/E30/E30P/E30WS/E30WSP

BKP-9057

CA-905K/F/T

CCU-790/790P

To an AC power source

Connecting the CCU-790/790P to the Video Camera

Page 13: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

Self-Diagnostics

The CCU-790/790P is equipped with the self-diagnostic function and you can display the self-diagnostics results of the system and the internal boards of the CCU-790/790P on the following monitors.• A picture monitor connected to the PIX connector• An SDI monitor connected to the VBS/SDI-3

connector1)

• The LCD/touch panel on the RM-B750 Control Panel2)

1)To select the SDI signal, switch setting on the internal board is necessary.For details on the setting, consult your Sony service personnel.

2)Press to light the MONITOR button on the RM-B750 to view the self-diagnostic results on the LCD/touch panel.

In all cases above, be sure to press to light the CHARACTER button on the RCP-750/751/920/921 Remote Control Panel.

To display the self-diagnostics pagesWhile the CHARACTER button on the remote control panel is turned off, press to light the button. The “Settings of the camera” page appears.

To display the next page of the self-diagnostics pagesPress the CHARACTER button on the remote control panel or the RM-B750.Each press of the button advances the page.When you press the CHARACTER button while the “ROM version indication” page appears, a screen with no characters (character OFF screen) appears.When you keep pressing the CHARACTER button, pages are automatically turned to the character OFF screen.

In this manual, self-diagnostics pages are shown in order of appearance.

The following illustrations of the self-diagnostics pages may differ from the actual indications depending on the settings and connections.

Settings of the camera

At the top of the screen, the following items are displayed from left to right: MASTER GAIN, CROP, EVS, SHUTTER, and SHUTTER ON/OFF.At the bottom of the screen, the following items are displayed from left to right: ND FILTER, IRIS, EXTENDER, and CC FILTER.

For the meanings of each item, refer to Operation Manuals of the video camera.

Status display of the camera system

BVP (the first column): Model name and format of the connected camera

CCU (the second column): Model name and format of the connected camera control unit

GenLock: The status of the external reference signalPrompter: Transmission direction of the teleprompter

signalD-sub15pin: Microphone input level setting performed

through the MIC REMOTE connectorReturn-1 to 4: The settings of the RET-1, RET-2/

PROMPTER, SDI RET-3/RET-4 connectors

Self-diagnostics of the camera system

The results of a self-diagnosis of the camera system are displayed in 3 pages.

Note

Self-Diagnostics 13

Page 14: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

14

Page 1

TRIAX Type: Type of Triaxial circuitTRIAX Cable: Triax cable connection status (connected/

disconnected)TRIAX Comp.: Cable compensation of a triax cable

(automatic/manual)TRIAX Step: Compensation step of the triax cable (step

indication in the circuit) (The cable length may not be displayed correctly.)

Fan Power: Fan status in the CCU power block Timer: Power up time to devices connectedCCU Power: Status of the CCU power supply SerialNo: Serial number of the CCU

Page 2

CAMERA Cable: Camera cable connection status (connected/short-circuited)

CAMERA Data: Camera data transmission statusCAMERA Power: Power supply status of the cameraCAMERA Tone: Camera ID tone status RCP/CNU Cable: Connection status of the REMOTE

connector (connected/short-circuited)RCP/CNU Data: Data transmission status of the

REMOTE connectorRCP/CNU Power: Power supply status of the REMOTE

connector

Page 3

Intercom CCU: CCU intercom selectionIntercom CAMERA CH1: Status of intercom 1 of the

camera (producer line/engineer line)Intercom CAMERA CH2: Status of intercom 2 of the

camera (producer line/engineer line)CHU MIC Gain: Gain and control status of the

microphone circuit

Settings of the network

The following pages appear only when the CCU-790/790P is set so that it connects to the system through the Ethernet.In order for the CCU-790/790P to establish connection via Ethernet, internal settings must be made.

For details on the internal settings, consult your Sony service personnel.

The network settings are displayed in 3 pages.

Page 1

MacAddress: Mac address of the CCU-790/790PAuto Negotiation: Auto-negotiation settingAuto Mdix: Auto-MDIX settingConnect Speed: Connection speed settingDuplex Mode: Duplex mode settingMDI/MDIX Select: MDI/MDIX settingLink Status: Ethernet connection status

Self-Diagnostics

Page 15: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

Page 2

NS Mode: Setting for the ETHERNET connection modeLEGACY: Connection mode for the REMOTE connector (factory-setting)BRIDGE: ETHERNET connection modeMCS: ETHERNET connection mode

MCS Mode: Setting of master or client for the Ethernet connection of the multi-camera systemCLIENT: Client mode (This unit is placed under control of the master device.)

CCU No.: CCU number settingMaster IP Address: IP address of the master device

Page 3

IP Addr: IP addressNetMask: Net maskDef GW: Default gateway

Self-diagnostics results of the CCU-790/790P internal boards

For details on the internal boards, refer to the System Manual.

DM board

CAM Video: Status of the Y, R-Y, and B-Y signals of the triax signal

Skin Gate: Reception status of the Skin gate signal from the camera

TRIAX Comp.: Cable compensation of a triax cable TRIAX Step: Compensation step of the triax cable (step

indication in the circuit) (The cable length may not be displayed correctly.)

Power: DM board power supply status

TR board

Prompter: Setting status of the prompter lineTone: Tone signal statusIncom: Demodulating status of the intercom lineCHU Data: Data reception status from the cameraPower: TR board power supply statusBoardID: ID number of the TR board

AT board

Reference: Operation mode of the phase adjustment

Self-Diagnostics 15

Page 16: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

16

Gen Lock: Locking statusCCU Power: CCU power supply type (AC/DC) and power

supply statusBATT Volt: Voltage of the coin battery supplied with the

AT boardPLL Volt: Status of the PLL circuit of the AT boardCCU Mode: Operation mode of the CCUPLD: Status of the PLD mounted on the AT board and

program version of the PLDBoard ID: ID number of the AT board

AU board

MIC: Audio embedding for the main SDI video signal.FRONT-INCOM: Settings of the front intercomINCOM: Channel setting for the intercom made on the

video cameraPGM: Program audio settingAudioPLL: PLL status of the audio signalPower: AU board power supply statusCN: CN board power supply statusPLD: Status of the PLD mounted on the AU board and

program version of the PLDBoard ID: ID number of the AU board

IV board

RETURN: Input settings for the return channels 1 to 4MIX-Y: Setting for camera signal to be mixed with the

return signalPower: IV board power supply statusDIF: Power status of the DIF board connected to the rear

of the IV boardPLD: Status of the PLD mounted on the IV board and

program version of the PLD

BoardID: ID number of the IV board

EN board

Component: Setting status of the component output signal from the OUTPUT connector and status of the sync signal added to the component Y/G output signal from the OUTPUT connector

Composite: Setting status of the composite output signal from the OUTPUT connector

Power: EN board power supply statusVDA: Power supply status of the VDA board on the rearSC-REF: Lock status to the subcarrier of the external

reference signalPLD: Status of the PLD mounted on the EN board and

program version of the PLDBoardID: ID number of the EN board

Self-diagnostics results of the camera internal boards

Self-Diagnostics

Page 17: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

ROM version indication

Exiting the Self-diagnostic mode

Press the CHARACTER button on the RCP-750/751/920/921 remote control panel or the RM-B750 repeatedly to display the ROM version indication page, then press the CHARACTER button again.

When an error occurs

The error message is displayed on the monitor. In such a case, the self-diagnostics page corresponding to the board where the error has occurred appears by pressing the CHARACTER button.

When you keep pressing the CHARACTER button, pages are automatically turned to a screen with no characters (character OFF screen).

Specifications

General

Power requirementsCCU-790: 120 VAC, 50/60 HzCCU-790P: 100 V/120 V/220 to

240 VAC selectable, 50/60 Hz (factory setting: 220 V to 240 V AC)

Power consumptionCCU-790: 3.5 A max. for entire systemCCU-790P: 4.2 A max. for entire

systemPeak inrush current

(1) Power ON, current probe method: 90 A (240 V)

(2) Hot switching inrush current, measured in accordance with European standard EN55103-1: 20 A (230 V)

Cable length1) 50 to 1,000 m (Fujikura φ8.5 mm)75 to 1,500 m (BELDEN 9232

φ13.2 mm)100 to 2,000 m (Fujikura φ14.5 mm)

Operating temperature+5 °C to +40 °C (41 °F to 104 °F)

Storage temperature–20 °C to +50 °C (–4 °F to +122 °F)

Dimensions 424 × 133 × 394 mm (163/4 × 51/4 × 155/8 in.) (w / h / d) not including projecting parts

Mass Approx. 12.0 kg (26 lb 7 oz)

1) Teleprompter signals are only compatible with the following cable lengths. • 50 to 500 m (Fujikura φ8.5 mm) • 75 to 750 m (BELDEN 9232 φ13.2 mm)• 100 to 1,000 m (Fujikura φ14.5 mm)

Input signals

REFERENCE BNC type (loopthrough)VBS/BS, 1.0 Vp-p, 75 ohms

RET-1/22) BNC type (1 each, loopthrough)VBS, 1.0 Vp-p, 75 ohms

PROMPTER2) BNC type (loopthrough)1.0 Vp-p, 75 ohms

SDI RET-3/43) BNC type (1 each) VBS, 1.0 Vp-p, 75 ohms (terminated

internally)SDI format, 270 Mbps, SMPTE 259M

2) The same signal is input to the RET-2 connectors and the PROMPTER connector.

3) The signal selection (SDI or VBS) input to the SDI RET-3/4 connectors is switchable.

Specifications 17

Page 18: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

18

Output signals

VBS/SDI-1/2/34) BNC type (1 each)VBS, 1.0 Vp-p, 75 ohmsSDI format, 270 Mbps, SMPTE 259M

SDI-4/5/65) BNC type (1 each)SDI format, 270 Mbps, SMPTE 259M

Y/R-Y/B-Y video6)

BNC type (1 each)Y: 1.0 Vp-p, 75 ohmsR-Y/B-Y: NTSC:

J: without setup, 756 mVp-p, 75 ohmsUC: with setup, 700 mVp-p, 75 ohms (factory setting)

PAL: 525 mVp-p, 75 ohmsR/G/B video6) BNC type (1 each)

700 mVp-p, 75 ohmsPIX BNC type (1)

1.0 Vp-p, 75 ohmsWF BNC type (1)

NTSC: 714 mVp-p, 75 ohmsPAL: 700 mVp-p, 75 ohmsEncoded output: 1.0 Vp-p, 75 ohms

WF MODE 4-pin (1)AUDIO OUTPUT

XLR, 3-pin0 dBu/–20 dBu, balanced, 2 channels

SYNC BNC type (1)0.3 Vp-p, 75 ohms

4) The signal selection (VBS or SDI) output from the VBS/SDI 1/2/3 connectors is switchable.

5) SDI signal is output only when SDI signal output is selected for the VBS/SDI-1 connector.

6) R/G/B and Y/R-Y/B-Y are switchable.

Camera input/output signals

CAMERA Triax (Kings type for the U.S.A. and Canada, Fischer type for Europe)

COAX BNC type (1), 75 ohmsREMOTE 8-pin, multiconnectorETHERNET IEEE 802.3 10BASE-T, IEEE 802.3u

100BASE-TXINTERCOM/TALLY/PGM

D-sub, 25-pin (1)4W/RTSTALLY: 24 V DC, TTL level or contact

selectableMIC REMOTE D-sub, 15-pin (1)INCOM (on the front panel)

XLR, 5-pin (1)

Supplied accessories

AC power cord (1)AC power plug holder (1)4-pin connector (1)Number plate (1 set)Operation Manual (1)CD-ROM (1)

Optional accessories

Extension board (service parts)

Design and specifications are subject to change without notice.

NoteAlways verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

Specifications

Page 19: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual.Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.

TrademarkEthernet is a registered trademark of Xerox Corporation.

Page 20: * 3-9 0 3-6 7 3-0 5 * CAMERA CONTROL UNIT CCU …pdf.crse.com/manuals/3903673051.pdfCAMERA CONTROL UNIT CCU-790/790P OPERATION MANUAL [English] 1st Edition (Revised 4) * 3-9 0 3-6

CCU-790/790P

(UC/CE)

3-903-673-05 (1)

Printed in Belgium

2008.05.08

© 2005

Sony Corporation

* 3 - 9 0 3 - 6 7 3 - 0 5 *